Tender For Special Repairs To Building No T-2 And T-3 At Afs Yelahanka, yelahanka-Karnataka

Tender Notice

52668475
Tender For Special Repairs To Building No T-2 And T-3 At Afs Yelahanka
Tender
Indian
Karnataka
Yelahanka
20-12-2025

Tender Details

Tender For Special Repairs To Building No T-2 And T-3 At Afs Yelahanka; 1 Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil complete all as specified and as directed. 2 Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in Hard/dense soil complete all as specified and as directed. 3 Returning filling in excavated soil upto a depth of 30 cm after riddling of excavated soil (in lieu of sand) for cushioning of cable and refilling of trenches with left over normal excavated soil including spreading, levelling, watering and well ramming in layers complete all as specified and as directed. 4 Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed. 5 Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc complete all as specified and as directed. 6 Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. 7 Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. 8 M&L for Dismantling of ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed. 9 Taking down plaster on wall built in cement mortar including racking out joints, hacking for key, scrubbing down with water etc., complete all as specified and as directed. 10 Taking down Chowkhats or frames exceeding 1.5 Sqm but n exc 4.0 Sqm each (Without taking off shutters from the frame) complete all as specified and directed. 11 Taking down Chowkhats or frames n exceeding 1.5 Sqm each (Without taking off shutters from the frame) complete all as specified and directed. 12 M&L Precast cement concrete block masonry with solid blocks in Type C1, 1:3:6 (20mm graded aggregate) exc 10cm in width and setting in cement mortar 1:6 complete all as specified and directed. 13 S&F Pressed steel frames size 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, and filling of hollow portion with PCC 1:3:6 type C1 etc., complete all as specified and directed. 14 S&F Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffener and fixed with 100 x 8 sheet metal CSK screws complete all as specified and directed. 15 S&F 35 mm thick factory made flush shutters, solid core construction, with block board core & plywood face panels, commercial type on both sides complete all as specified and directed. 16 S&F Factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4 or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, complete all as specified and directed. 17 S&F Factory made steel window box type using ERW hollow P section comprising double frame for and including glazed Skeleton shutter jointed internally with flat iron 40x4mm complete including grill of 8mm square bars, fixed horizontally @ 10cm c/c, hinges, handle, tower bolts, stops, lugs etc. all as shown on drawing No. AFB /TD/A/002 dated 21 May 2023as applicable complete. Note: (i) Unit rate quoted against this item shall also include the iron mongery and grill as shown on drgs.(ii) Glazing & painting shall be measured & paid for separately. 18 S&F Providing & fixing 12mm false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of perforated Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0 .50 to 0.75 as per IS 8225 :1987, Noncombustible as per BS tiles tiles 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter- locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main- T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm , suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1OOOmm length and L-shape level adjuster of size 85x25x2mm .Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications , drawing including three coats of white wash complete all as specified and directed. 19 S&F Mineral fibre board, 12mm thick fixed in ceiling as per manufacturers instructions complete all as specified and directed. Make : Armstrong or its equivalent 20 S&F 300 mm long aluminium anodised sliding door bolt with hasp, staple cast type complete all as specified and as directed. 21 S&F extrudedaluminium alloy handles fabricated type 150 mm size, anodized complete all as specified and directed. 22 S&F Aluminium anodized barrel tower bolt of extruded section 150 mm length complete all as specified and directed. 23 S&F plain sheet glass 4mm thick, ordinary quality and glazing with oil putty or using EPDM Gaskets in squares n.exc 0.50 Sqm in each pane complete all as specified and directed. 24 S&F pre-painted galvalume aluminium zinc coating GI based corrugated sheet 0.50 mm thick of any colour having tensile strength 550 MPa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. 25 S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. 26 M&L for 25mm thick cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregate) for slab flooring, complete all as specified and directed. 27 M&L for light shade Vitrified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm and n exc 1.00, in floors etc. set and jointed in neat cement slurry over and including 15 mm thick screed bed in CM 1:6, and pointed in coloured cement to match complete all as specified and as directed. 28 M&L for Non-skid ceramic tiles 7 to 8mm thick, joint free coloured tiles (square/rectangular) area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:6, and pointed in coloured cement to match complete all as specified and as directed. 29 M&L light shade Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm and n exc 1.00, set and jointed in neat cement slurry over and including 10 mm thick plaster in CM 1:4, and pointed in coloured cement to match in skirting etc complete all as specified and as directed. 30 M&L for glazed ceramic coloured tiles, size 450x300x7mm size as in walls, set and jointed in neat cement slurry over and including 10mm thick backing coat in cement mortar (1:3) and pointed in coloured cement to match for work on vertical surface such as skirting/dado etc complete all as specified and as directed. 31 M&L for rendering 15mm thick in CM 1:6 on brick work or concrete surfaces and surface is to be finished even & smooth without using extra cement complete all as specified and directed. 32 M&L Rendering 15mm thick in CM 1:4 on brick work or concrete surfaces and surface is to be finished even & smooth without using extra cement complete all as specified and directed. 33 M&L for applying 02 coats of interior emulsion paint (white shade) @ 10 sq.m/litre/2 coats to wall surfaces over & including a coat of interior primer @ 10 sq.m/litre/1 coat over a coat of wall putty 1 to 2mm thick on new surface of wall as recommended by manufacturer of interior emulsion complete all as specified and directed. 34 M&L for applying 02 coats of exterior emulsion paint (light shade) @ 5 sq.m/litre/2 coats by using roller/brush to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat on new surface of wall recommended for under coat by manufacturer of exterior emulsion complete all as specified and directed. 35 M&L for applying 02 coats of interior emulsion paint (white shade) @ 10 sq.m/litre/2 coats to wall surfaces over & including a coat of interior primer @ 10 sq.m/litre/1 coat over a coat of wall putty 1 to 2mm thick including complete removal of existing surface of wall as recommended for under coat by manufacturer of interior emulsion complete all as specified and directed. 36 M&L for applying 02 coats of exterior emulsion paint (light shade) @ 5 sq.m/litre/2 coats by using roller/brush to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat including complete removal of existing surfaces as recommended for under coat by manufacturer of exterior emulsion complete all as specified and directed. 37 S&F in repairs Vitreous China Wash down water closet pan (Pedestal pattern), white including seat cover, P trap and fixing bolt etc (excluding flushing cistern and flush pipe) complete all as specified and directed. 38 S&F in repairs Wash basins, Vitreous China (flat back or angle back type) ofsize 630 x 450mm, including brackets, waste fittings etc complete all as specified and as directed. 39 S&F in repairs Vitreous china urinals, bowl type of size 465x355x265mm white (minimum) with grating and union for discharge pipe (excluding flushing cistern and waste pipe), including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, flush pipe, waste pipe grating and union for discharge pipe, complete all as specified and directed. 40 S&F in repairsPVC valveless, syphonic action type, low level PVC flushing cistern 10 ltr capacity white with flush pipe & all fitting complete all as specified and directed. 41 S&F in repairs 15mm dia Pillar taps, fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed. 42 S&F in repairs 15mm dia bib taps with wall flange (Fancy type), cast copper alloy, screwed down, screwed for iron pipe or for brass ferrule with check nut, complete all as specified and directed. 43 S&F in repairs PVC connection 15mm size with PTMT nut of length 600mm etc complete all as specified and directed. 44 S&F in repairs CP health faucet suitable for 15 mm dia pipe including necessary holding arrangements, screws etc complete all as specified and directed. 45 S&F in repairs 600 x 450mm bevelled edge mirror of selected quality glass 5.0/ 5.5mm thick mounted on standard PVC/Aluminium frame complete all as specified and directed. 46 S&F in repairs 15mm dia Angle cock with wall flange (Fancy type), cast copper alloy, chromium plated, screwed down, screwed for iron pipe or for brass ferrule with check nut complete all as specified and directed. 47 Taking up or down 15mm steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed. 48 S&F GI tubing 15 mm dia medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. 49 M&L preparation of new steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. 50 M&L for preparation of new wooden surfaces of any descriptionnot otherwise described over 10 cm width or girth and applying two coat of Synthetic enamel paint over a coat of pink primer on wooden surfaces of any description complete all as specified and as directed. 51 Taking up/down steel tubing of 25mm sizes and disconnections of fitting, joints from tubing where required complete all as specified and directed. 52 Taking up/down steel tubing of 40mm sizes and disconnections of fitting, joints from tubing where required complete all as specified and directed. 53 Supply and laying GI tubing of 25mm sizes in walls/ceilings or laid in floors ofmedium grade ISI marked including all types of fittings such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions etc and accessories complete all asspecified and directed. 54 Supply and laying GI tubing of 40mm sizes in walls/ceilings or laid in floors ofmedium grade ISI marked including all types of fittings such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions etc and accessories complete all asspecified and directed. 55 Supply and fixing in repairs Gun metal gate valve/globe valve of 25mm sizes ISI marked with Iron wheel head screwed both end for GI tubing complete all as specified and directed. 56 Supply and fixing in repairs Gun metal gate valve/globe valve of 40mm sizes ISI marked with Iron wheel head screwed both end for GI tubing complete all as specified and directed. 57 Construction of valve chamber of Internalsize900mm x 900mm x 900mm deep with 200mm thick PCC block masonry walls built in CM 1:6 over 100 mm thick foundation concrete in PCC 1:4:8 type D2, (Using 40 mm graded coarse aggregate) with 100 mm off sets, 15mm thick complete internal plaster and external plaster up to a depth of 15 cm below GL in CM (1:6), 3 mm thick MS sheet cover, double door welded to 50 mm x 50 mm x 6mm MS angle frame fixed with hold fasts, 20mm x 6mm flat iron hinges with locking arrangement including lock sixty five mm, brass and keys , MS handles and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer to all steel surfaces including excavation & earth work in any type of soil /soft disintegrated rock and disposal of surplus soil to a distance not exceeding 50 mtr complete all as specified and directed. 58 Cutting the existing bituminuos road of suitable size for passing of UG Cable/pipeline in road crossing and making good the disturbed surface of road to its original specification complete all as specified and directed. 59 M&L for cutting of existing GI pipe 50 mm dia and provide new tee 50x50x40mm insert in the existing pipe and make a new branch for tapping the pipe complete all as specified and directed. 60 S&F Rotational moulded polyethylene water storage tanks of 500L capacity (cylindrical vertical with closed top) hoisted and fixed in position along with all necessary fittings etcincluding dismantling of existing water tanks complete all as specified and directed. 61 S&F in repair Ball valves of 20mm dia high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed along with all necessary fittings like nipple, socket etc complete all as specified and directed. 62 Supply and laying in trenches, LT underground cable, XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross sectional area 35 Sqmm, 3.5 core multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as specified and as directed. 63 Supply and laying in trenches, LT underground cable, XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross sectional area 25 Sqmm, 4 core multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as specified and as directed. 64 Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 flat, size 250 mm x 150mm x 40mm complete all as specified and as directed. 65 Supply, install , testing & commissioning of bus bar panel, outdoor cubical type, floor mounted on MS angle iron frame of size 50 x 50 x 6 mm thick, made out of 3.15 mm thick CRCA sheet powder coated for load bearing members for double doors both side openable and covers, Suitable for 3 phase 4 wire 50 cycle 415 Volts system weather and vermin proof, including heat shrinkable sleeves, chromium plated brass cable glands for entry of 4 cables, lugs, 2000Amps Busbar and necessary excavation earth work, PCC grouting etc. to comprising of the following, with and including taking down old unserviceable burned out/damaged bus bar panel, incl removing of old cable connectionafter installation of bus bar Panel with reconnection of old cable complete all as directed.(a) MCCB 800Amps 4Pole 50KA 415V, 50Hz (Main Incoming) -01 No(b) Digital type panel mounted 3 phase Voltmeter with LED display - 01Nos(c) Digital type panel mounted 3 phase Ammeter incl suitable CT with LED display - 01 Nos.(d) Indicator lamp RYB LED type(3 Nos) - 01 Set 66 Supply and fixing cable routeindicator,made of MS sheet of size 200 mm x 150 mm x 3 mm thick,spot welded with angle iron of size 40 x 40 x 5 mm thick, 750 mm long embedded in PCC (1:2:4) type B-2 ( using 40mm graded crushed stone aggregate) block 30cm x 30cmx 40cm in ground including one coat of synthetic enamel black paint over one coat of red oxide zinc chrome primer and writing with white paint and showing size of cable HT /LT complete all as specified and directed. 67 Taking down existing unserviceable point wiring of any type/size of light/fan/socket/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site area complete all as specified and directed. 68 Taking down existing unserviceable light fittings, security light fittings, bulk head fittings, fall ceiling light fittings etc. from any height of building complete all as specified and directed. 69 Taking down existing unserviceable Distribution boards with MCBs/MCCBs of any capacity complete all as specified and directed. 70 Taking down earthing material, plate and pipe etc from 2.25 mtrs depth complete all as specified and directed. 71 M&L for Point wiring complete with two runs of 1.5 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded, copper conductor FRLS cable of 1100V grade drawn through and including new non metallic rigid PVC concealed conduit medium grade, ISI marked, 20 mm bore with conduit accessories for wiring concealed in wall, including provision of fabricated branded pressed steel terminal box concealed of suitable sizes with 1.6mm thickness including modular cover frame & box of suitable size for modular switch boards/sockets/regulators of any size modules for housing modular switches, sockets, fan regulators etc and provn of 1.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc. complete all as specified and as directed for one light point controlled by one switch.Note(1) The wiring shall be done in proper colour coding using red, yellow, blue for phases, black for neutral and green for earth.(2) The cost ofcutting of chases of required width and depth for concealed conduit including plastering, making good to disturbed surface, painting two coats to match the existing wall colour is deemed to be included in the quoted rate by the contractor. 72 All as per Sl item No 71 above but for One ceiling fan/exhaust fan point controlled by one switch through modular regulator complete all as specified and as directed. 73 All as per Sl item No. 71 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent modular board complete all as specified and as directed. 74 All as per Sl item No. 71 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same modular board complete all as specified and as directed. 75 M&L for Point wiring complete with two runs of 4 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded, copper conductor FRLS cable of 1100V grade drawn through and including new non metallic rigid PVC concealed conduit medium grade, ISI marked, 20 mm bore with conduit accessories for wiring concealed in wall, including provision of fabricated branded pressed steel terminal box concealed of suitable sizes with 1.6mm thickness including modular cover frame & box of suitable size for modular switch boards of any size modules for housing modular switches, sockets,etc and provn of 4 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc. complete all as specified and as directed for one 15 Amps socket outpoint independent boardNote(1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.(2) The cost ofcutting of chases of required width and depth for concealed conduit including plastering, making good to disturbed surface, painting two coats to match the existing wall colour is deemed to be included in the quoted rate by the contractor. 76 S&F single pole Modular switch 1 way 6 Amps, 1 Module complete all as specified and as directedNote:(i)All light/fan switches shall besymbol embossed (light/fan) typecomplete all as specified and as directed.(ii) All switches for sockets shall be LED indicator type. 77 S&F single pole Modular switch 1 way 16 Amps, 1 Module with red LED indicator complete all as specified and as directed. 78 S&F Socket modular type multipurpose 2/3 Pin, 6 amps, 230 volts 2 Module complete all as specified and directed. 79 S&F Socket modular type multipurpose 3/6 Pin, 16 amps, 230 volts 2 Module complete all as specified and directed. 80 S&F Modular ceiling fan regulator stepped socket size, 2 module suitable to work on 230 volts complete all as specified and as directed 81 S&F ceiling rose three terminal surface bakelite type AC 50 Hz, 230 volts of size 65 x 50 mm complete all as specified and as directed 82 S&F LED batten light fitting 20 Watts 4 feet surface / wall mountedaluminium extrusion input voltage range 250 V, input frequency 50 Hz, efficacy including 2 nos PVC Connector blocks electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. 83 S&F LED batten light fitting 10 Watts 2 feet surface / wall mountedaluminium extrusion input voltage range 250 V, input frequency 50Hz, including 2 nos PVC Connector blocks electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. 84 S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. 85 S&F LED security light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant, efficacy complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with wall mounting bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 42 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enamel paint over a coat of red oxide primer complete suitable for pop/grid false ceiling in all respect complete all as specified and directed. 86 M&L for Making suitable size Core cutting on stone/Bricks wall for fixing of exhaust fan 230 mm sweep and making good to the disturbed surface complete all as specified and directed. 87 S&F exhaust fan, steel body AC single Phase 230V of size 230 mm sweep with, blades, and frame and louvers complete all as specified and directed. 88 S&F MCB SP 6 to 32 Amps 240 volts C type with rupturing capacity 10 KA complete all as specified and as directed. 89 S&F MCB SPN 40 to 63 Amps 240 volts C type with rupturing capacity 10 KA complete all as specified and as directed. 90 S&F MCB TPN, 63 Amps, rupturing capacity 10 KA, 415 volts suitable for fixing in existing DB of any capacity complete all as specified and as directed. 91 S&F sheet metal enclosure MCB DB SPN 8 way double door with 100 amps rated aluminium bus bar 240 volts double door with locking system complete all as specified and as directed. 92 S&F of TPN DB 4 way double door horizontal made out of CRCA sheet housing duly powder coated & confirming to IS specification complete all as specified and as directed. 93 M&L Submain concealed wiring with 2 runs of single core 6 sqmm PVC insulated FRLS multistranded 1100 volts grade wire, copper conductor drawn through and including non-metallic rigid PVC concealed conduit and conduit accessories of medium grade not less than 25mm dia including one run of single core 6 sqmm PVC insulated sheated multistranded 1100 volts grade with copper conductor cable as earth continuity conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain wiring complete all as specified and as directed.Note:-(1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.(2)The cost ofcutting of chases of required width and depth for conduit including plastering, painting two coats to match the existing wall colour is deemed to be included in the rate quoted rate.(3) The two runs of copper wire, one run of PVC conduitshall be measured as one running metre. 94 M & L for removing defective ceiling fan from the site, rewinding of the ceiling fanof any sweep upto 1400mm complete with equivalent new super enamelled copper wire as per existing gauge and weight as per manufacturers design and instructions including varnishingcomplete including taking down, transportation, assembling back and refixing all as specified and directed . Note : 1.The items are to be removed from the site to betaken for rewinding from MES stores and returned to MES stores after necessary repair works. 2. The transportation for the same is inclusive of the rate quoted. 95 Taking out defective capacitor and supply and fix new capacitor of 2.5 mfd of approved make with holding clamp for various makes of ceiling fans complete all as specified and as directed. 96 M & L of Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GIearth lead wire 4 mm dia by means of bolts, nut, check nuts and washers etc of galvanised iron and earth lead protected by provision of GI pipe 15 mm bore of medium grade from earth electrode to DBs/Main switch all as shown in Electrical Plate No 3 of SSR Part I and connected to main switch board including excavation and earth work in any type of soil, PCC chamber in 1:2:4 Type B-1 using 20 mm graded stone aggregate 75 mm thick RCC cover in 1:2:4 type B-1 reinforced with 6mm dia bars at 75mm c/c both ways with 12mm dia MS bar handle made to shape, 20 mm dia medium grade GI watering pipe perforated at bottom with funnel and wire mesh, common salt and charcoal filling complete including testing on completion all as specified (Note: GI pipe 15mm dia & GI earth lead 4mm dia upto 7.5 m length is deemed to be included in quoted rate).Note:-(a)Earthing value should be less than 5 ohms.(b)If desired value of earth resistance not achieved during testing, the earthing work shall be redone by the contractor at free of cost to achieve the desire value of earthing resistance. The rate quoted by the contractor deemed to be inclusive of the provision. 97 M&L for Earthing complete with galvanised steel earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to and inclduing GI Strip32X6 mm as earthing lead, by means of bolts, nuts, check nuts and washers of galvanised iron all as shown in electrical plate No 5 of MES SSR Part I and testing on completion inclduing excavation and earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS frame and cover 6 mm thick in cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric or XPM (weight not less than 4 Kg per Sqm) with cast iron frame, funnel with wire mesh, GI watering pipe 20mm dia medium grade and lugs complete all as specified and directed.Note:-(a)Earthing value should be less than 5 ohms.(b)If desired value of earth resistance not achieved during testing, the earthing work shall be redone by the contractor at free of cost to achieve the desire value of earthing resistance. The rate quoted by the contractor deemed to be inclusive of the provision.

Key Value

Document Fees
INR 500 /-
Tender Value
INR 48.80 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail