| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 06-03-2026 | Date Corrigendum 6 | Date | 16-04-2026 |
| 2 | 12-02-2026 | Date Corrigendum 5 | Date | 16-03-2026 |
| 3 | 10-02-2026 | Corrigendum for clarification on drawing and BoQ | Other | 16-02-2026 |
| 4 | 09-02-2026 | Date Corregendum | Date | 16-02-2026 |
| 5 | 02-02-2026 | Other Corrigendum | Other | 12-02-2026 |
| 6 | 30-01-2026 | Corrigendum for change in BoQ | BOQ | 12-02-2026 |
| 7 | 28-01-2026 | Corrigendum for uploading revised drawing STRUC | Other | 12-02-2026 |
| 8 | 28-01-2026 | Corrigendum for uploading revised drawing ARCH3 | Other | 12-02-2026 |
| 9 | 28-01-2026 | Corrigendum for uploading revised drawing ARCH2 | Other | 12-02-2026 |
| 10 | 28-01-2026 | Corrigendum for uploading revised drawing | Other | 12-02-2026 |
| 11 | 28-01-2026 | Corrigendum for change in BoQ and tender documents | BOQ | 12-02-2026 |
| 12 | 23-01-2026 | DateCorrigendum3 | Date | 12-02-2026 |
| 13 | 06-01-2026 | Date Corrigendum | Date | 03-02-2026 |
| 14 | 18-12-2025 | drawings | Other | 17-01-2026 |
| 15 | 17-12-2025 | Date_Corrigendum | Date | 17-01-2026 |
| Sl. No. | Item Description |
| 1 | Schedule \"A\" Part – I to Schedule \"A\" Part – XVI:NOTE: Schedule \"A\" Part – I to Part – XVI are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only |
| 2 | Lumpsum price worked out by the contractor for \"Buildings/Structures\" as listedin Schedule \"A\" Part – I |
| 3 | Lumpsum price worked out by the contractor for \"SITE CLEARANCE& AREA DEVELOPMENT/ EARTH WORK/EXCAVATION\",as listed in Schedule \"A\" Part – II |
| 4 | Lumpsum price worked out by the contractor for \"Road/ Path & Culvert\" as listed in Schedule \"A\" Part – III |
| 5 | Lumpsum price worked out by the contractor for \"SEWAGE DISPOSAL\", as listed in Schedule \"A\" Part – IV |
| 6 | Lumpsum price worked out by the contractor for \"Area Drainage\", as listed in Schedule \"A\" Part – V |
| 7 | Lumpsum price worked out by the contractor for \"COMPOUND WALL/ GATE\",as listed in Schedule \"A\" Part – VI |
| 8 | Lumpsum price worked out by the contractor for \"Spl Items (B&R)\", as listed in Schedule \"A\" Part – VII |
| 9 | Lumpsum price worked out by the contractor for \"INTERNAL WATER SUPPLY\",as listed in Schedule \"A\" Part – VIII |
| 10 | Lumpsum price worked out by the contractor for \"INTERNAL ELECTRIFICATION\",as listed in Schedule \"A\" Part –IX |
| 11 | Lumpsum price worked out by the contractor for \"EXTERNAL WATER SUPPLY\",as listed in Schedule \"A\" Part –X |
| 12 | Lumpsum price worked out by the contractor for \"EXTERNAL ELECTRIFICATION\",as listed in Schedule \"A\" Part – XI |
| 13 | Lumpsum price worked out by the contractor for \"LIGHTENING PROTECTION\",as listed in Schedule \"A\" Part – XII |
| 14 | Lumpsum price worked out by the contractor for \"FIRE FIGHTING SYSTEM\",as listed in Schedule \"A\" Part – XIII |
| 15 | Lumpsum price worked out by the contractor for \"FIRE ALARM & DETECTION SYSTEM\",as listed in Schedule \"A\" Part – XIV |
| 16 | Lumpsum price worked out by the contractor for \"Misc TV & Conduit\",as listed in Schedule \"A\" Part – XV |
| 17 | Lumpsum price worked out by the contractor for \"Arboriculture\",as listed in Schedule \"A\" Part – XVI |
| 18 | Schedule \"A\" Part - XVII: (Miscellaneous Items) (Sewage Disposal, Compound Wall/ Gate, Spl Item (B&R), Internal Electrification, External Water Supply, External Electrification, Fire fighting System, Fire Alarm & Detection System, Lightening Protection, LIFT, Aviation Light, DG SET, Misc TV & Conduit, Hot Water supply, Electric Chimney & Arboriculture) |
| 19 | Sewage Disposal |
| 20 | M&L for SRFC Factory made Manhole cover 900x 600mm shape for using cover to manholes complete as specified and directed |
| 21 | Construction of RCC septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 design mix in walls, base slab, baffle walls and roof slab including beams etc., with vent shaft, manhole openings with covered connection etc., complete with effective depth of 1.5m with overall depth of 3.0 m for 150 users |
| 22 | Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFR cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2m dia and 1.5m effective depth |
| 23 | Compound Wall/ Gate |
| 24 | S&F wicket gate for entry and exit using 5.5 mm MS square bars as per site requirement including priming and painting complete all as specified and as directed. |
| 25 | External Water Supply |
| 26 | M&L laying of ductile iron pipe 80mm dia. with spigot and socket end centrifugally (spun) cast class K-9 conforming to IS-8329 including provision of specials, such as tees, elbows, bends reducers, taper pieces (measure separately), including testing and commissioning complete. |
| 27 | Supply and fix flanged end lift type Foot valve 100 mm dia with brass strainer, suitable flanges, nuts, bolts, gaskets confirming to IS 4038 complete all as specified and directed. |
| 28 | M&L for valve chamber of internal size 750x750x750mm comprising of 50mm thick PCC 1:5:10 type E2 foundation, 200mm thick brick wall in CM 1:6, 15mm thick plastering in CM 1:4 internally and externally up to 50mm below GL,100mm thick PCC 1:3:6 type B1 as in copings,3mm thick MS sheet cover with suitable hinges and locking arrangement, painting steel surfaces with two coats of synthetic enamel paint over a coat of primer including necessary earth work and excavation in any type of soil complete. |
| 29 | Cutting existing 80 mm steel tubing for alterations or additions necessarily done in position without taking down and inserting Tee of 80 x 80 x 80 mmfor tapping all as specified and directed. |
| 30 | Supply and installation of monoblock pump set suitable for 415 V ,3 phase system having capacity 5 HP.(01 to deliver water from sump to Bldg terrace tank, 01 standby) |
| 31 | M&L earthing complete with GI plate electrode 60cmx60cmx6mm thick, buried directly in ground (Earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron earth strip 32×6mm size by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 15mm bore GI light grade earth lead protection pipe, and 50mm thick RCC cover slab with handle, reinforced with 10mm dia. bars in both the directions, funnel, strainer, charcoal and testing on complete Note: Rate quoted deemed to include GI protection pipe, funnel, excavation and earth work, in any type of soil with PCC type C1 in bed and pit complete all as specified and as directed. |
| 32 | Internal Electrification |
| 33 | Supply and fixing LED adore lamp for AC 240Volt supply, B22 type, CDS five star, 12 watts of five star rated complete all as specified and as directed. |
| 34 | Supply and fixing ceiling fan, AC single phase 230 V of size 1200 mm sweep, copper wound with complete set and fixtures such as canopy, down rod etc. 5 Star rating, wit brushless direct current motor (BLDC) including making necessary electric connection from ceiling rose to fan connectr with twin core flexible copper wire all as specefied and directed. |
| 35 | S&F Exhaust fan 250 mm sweep or nearest size, plastic body (Heavy duty), complete with louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening, fixing and making good the distrubered surfaces etc complete with and inclussive of making necessary electric connection from ceiling rose to fan through twin core flexible wire all as spcified and as directed. |
| 36 | S&F Exhaust fan 300 mm sweep, (Heavy duty), complete with louvers suitable for operation on 240 V AC, 50 Hz AC supply fixed on wall including making of neccessary opening, fixing and making good the disturbed surfaces etc complete with and inclussive of making necessary electric connection from ceiling rose to fan through twin core flexible wire all as specified and as directed. |
| 37 | S&F Energy efficient LED tube light fitting with tube 5 watts or nearest size, 240V, 50hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed |
| 38 | S&F Energy efficient LED tube light fitting with tube 10 watts or nearest size 240V, 50hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed |
| 39 | S&F Energy efficient LED tube light fitting with tube 20 watts or nearest size, 240V, 50hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed |
| 40 | S&F LED Security light fitting with tube 30W New generation Energy saving &environmental friendly long life made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening separate driver compartment with IP66 protection pre wired with 1.0 Sq mm copper conductor cable upto connector including 1.5 m long GI Tubing light grade of 32mm dia bend to shape for fixing on wall/pole with suitable MS brackets nuts and bolts etc complete all as specified and as directed. |
| 41 | S&F concealed in wall Vertical MCB DB double door type, TPN 4 way 415V, 50Hz, IP 43 protection, including provision for fixing MCCB FP as incomer and outgoing circuits MCB SP/TP complete, fill empty way with blanking plates complete all as specified and directed. |
| 42 | S&F RCBO, DP, 240V, 50Hz, 16KA of capacity 20 Amp all as specified and directed. |
| 43 | S&F MCB SPN, 6 to 32 Amps 240 Volts, 10KA, C curve all as specified and directed. |
| 44 | S&F MCB SP, 6 to 32 Amps 240 Volts, 10KA, C curve all as specified and directed. |
| 45 | Supply, install, testing and commissioning integrity of Smart Meter single phase as per BIS 16444 with communication technology including cellular/RF/Hybrid (Cellular + RF ) AC whole current, Smart Energy Meter of rating 10-40 Amps complete as per specifications, meter shall have the ability to communicate with Head End System (HES) on any one of the communication technologies mentioned in IS 16444 Part I (RF/ Cellular) in a secure manner, in case of Cellular based meter, the meter shall accommodate e-SIM / SIM of any service provider, the Smart Meter shall have a dedicated sealable slot for accommodating plug-in type, bi-directional communication module which shall integrate the respective communication technology (RF/PLC/Cellular) with the Smart Meters, leading to easy adaptability for network interfaces (WN/NAN), the Plug-In module shall be field swappable / replaceable complete all as specified and directed. |
| 46 | Note: (i) Meter Specification may please be read in co-junction with the relevant PS clause. |
| 47 | (ii) 15 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, monthly billing survey for cumulative energy and max demand of software. |
| 48 | (iii) Meter should have connect / disconnect functionality operate able from MDM/ billing software and prepaid features would be configured in MDM/ billing end as per prevalent IS and applicable tariff plan. |
| 49 | (iv) Meter should support communication protocol through RF (4G/5G/NB/IOT) with the software all as required at site and directed (cost of 4G/5G/NB IOT SIM, mapping vending portal charges etc. deemed to be included the unit rate quoted for meter). |
| 50 | (v) Two way communication with DCU/HES. |
| 51 | (vi) Clock synchronisation facility with HES (Head end system). |
| 52 | (vii) In case of RF, communication including different makes of meter shall be such that it should communicate with same DCU directly via mesh network. |
| 53 | (viii) Guarantee of meter shall be 10 years from date of completion. |
| 54 | (ix) The cost of meter shall include DCU / repeater cost in case of RF communication meters. |
| 55 | (x) The OEM shall need to share the Authentication / Encryption keys of the meters along with relevant protocol details with the department. |
| 56 | (xi) A training to handle the smart meter to MES tradesmen shall also be given by professionals. |
| 57 | (xii) The Contractor / OEM will be held responsible for interface with the existing server of any make of MES at Visakhapatnam and testing the system complete all as specified and directed by Engineer-in-Charge. |
| 58 | External Electrification |
| 59 | Supply and installation of Ring main unit one incoming three outgoing ( 4 way ) SF6 filled load break switch each of 11 KV ,630 Amp complete. |
| 60 | Supply and fix sandwich type bus bar trunking system indoor for the complete bldg power supply three phase of rating 250 Amps, 25 KA 415 Volts aluminium conductor galvanised GI enclosure 1.6 mm thick (Non painted) IP54 rating including end feed unit with MCCB 250 A 25 KA 4P with rotary handle, termination links of bldg including following: a) Supply and fix Straight feeder - 27 RMb) Supply and fix Flange end - 01 Nosc) Supply and fix End Cover - 01 Nosd) Supply and fix Brackets - 10 Nose) Supply and fix Springs Hangers - 10 Nosf) Supply and fix Adaptor box as required. 01 Jobg) Supply and fix Copper braided flexibles as required. 01 Jobh) Supply and fix External aluminium earth strip 25x6.3 mm - 54 RMj) Supply and fix MS Centre feed Unit IP 54 - 01 Nosk) Supply and fix 63 A TAP OFF Box Prov for MCB as required.- 08 Nos |
| 61 | Supply and Installation , testing and commissioning distribution Transformer step down, outdoor type, 11//0.433 KV with HT 3 phase and LT 3 phase 4 wire system copper wound with off load tap changing arrangement on HT side for a variation of secondary voltage +/- 7.5% insteps of 2.5% continuous rating of 160 KVA outdoor type confirming to (IS 1180, level-II) with and including the following: a) Lifting lugs/ hooks for transformer and tank. (b) Earthing terminal rating and diagram plate. (c) Air release device. (d) Oil filling inlet pipe with plug. (e) Drain outlet pipe with brass gate valve with dummy plug. (f) Conservator with level gauge. (g) Silica gel breather (h) First oil fill up upto the recommended level by manufacturer with new oil conforming to IS 335. (i) Type of connection : Delta/Star. (j) Type of cooling : ONAN. (k) Vector Group : DYN 11. (l) Type of connecting arrangement : Cable termination boxes on both HT and LT side. (m) Temperature rise over an ambient of 50 degree centigrade maximum.(n) All necessary arrangements with devices for measuring the temperature of core, winding and oil.(o) In addition to the above all standard fittings shall be provided as per IS norms. |
| 62 | LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type CPRI approved, totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switch gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 600 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:(Main LT Panel ) |
| 63 | Incoming: |
| 64 | (a)MCCB 4 Pole, 415 V, 36 KA(ICS=ICU=ICW for 1 Sec), with microprocessor release (EDO type) of capacity 400 Amps, with adjustable type overload protection, short circuit protection. - 01 No. |
| 65 | Outgoing: |
| 66 | a)MCCB 4 Pole, 415 V,36 kA (ICS=ICU=ICW for 1 Sec), with microprocessor release (EDO type) of capacity 320 Amps, with adjustable type overload protection, short circuit protection. - 02 Nos.(trunking System, 01 spare) |
| 67 | b)MCCB 4 Pole, 415 V,25 kA (ICS=ICU=ICW for 1 Sec), with microprocessor release (EDO type) of capacity 100 Amps, with adjustable type overload protection, short circuit protection. - 03 Nos.(01 for DG Standby, 01 for APFC Panel 01 spare) |
| 68 | c)Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs of each breakers |
| 69 | d) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases for each breakers |
| 70 | LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type CPRI approved, totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switch gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 200 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:(DG Standby Panel) |
| 71 | Incoming: |
| 72 | (a)MCCB 4 Pole, 415 V, 25 KA(ICS=ICU=ICW for 1 Sec), with microprocessor release (EDO type) of capacity 100 Amps, with adjustable type overload protection, short circuit protection. - 01 No. |
| 73 | Outgoing: |
| 74 | a)MCCB 4 Pole, 415 V,16 kA (ICS=ICU=ICW for 1 Sec), with microprocessor release (EDO type) of capacity 32 Amps, with adjustable type overload protection, short circuit protection. - 05 Nos.(01 for booster, 02 Nos for lifts, 01 No for fresh water pump and 01 spare) |
| 75 | b)MCB TPN, C-Curve, 20 A ISI marked 50 Hz - 02 nos ( street light, 01 for spare) |
| 76 | c)MCB SPN, C-Curve, 20 A ISI marked 50 Hz - 01 nos (for common area) |
| 77 | d) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs of each breakers |
| 78 | e) Timer switch with control relay/contactor - 01 No |
| 79 | f) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases for each breakers |
| 80 | M&L earthing complete with GI plate electrode 60cmx60cmx6mm thick, buried directly in ground (Earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron earth strip 32×6mm size by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 15mm bore GI light grade earth lead protection pipe, and 50mm thick RCC cover slab with handle, reinforced with 10mm dia. bars in both the directions, funnel, strainer, charcoal and testing on complete Note: Rate quoted deemed to include GI protection pipe, funnel, excavation and earth work, in any type of soil with PCC type C1 in bed and pit complete all as specified and as directed. |
| 81 | Supply, install, testing and commissioning of factory made APFC panel CPRI approved OEM, free standing floor mounted, dust and vermin proof Automatic Power Factor Correction [APFC] Panel of capacity of 60 KVAR with 4 steps ( 4x15 )Compartmentalised, indoor type, fabricated as per IEC 61921 with 2 mm thick CRCA Sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces with minimum IP 43 Ingress Protection suitable for 3 Phase, 415 V & 50 Hz System with MD-XL Capacitor including suitable rated TPN, MCCB, 415 V, 35 KA rupturing capacity as incomer duly controlled by Auto and Manual option including instrumentation such asPower Factor Meter – 1 Nos, Digital type Ammeter of Range 0 to 250 Amps with CTs & Selector Switch – 1 Nos, Digital type Volt Meter of Range 0 – 500 V – 1 Nos, Relay, Auxiliary Contacts, CTS, Phase Indicating LED Lamps [RYB], Selector switches etc., suitable internal wiring with copper cable of suitable size, double stud hinged door, front openable with locking arrangement including interlocking with switch gears complete andpanel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level including connecting up with existing incoming and outgoing cables etc. complete all as specified and as directed. |
| 82 | Supply and fix Loop in loop out boxwith terminal of(minimum size-155 x 210 x 92)of FRP made with IP 65 protection of thermoplastic circuit breaker boxes with metric knockouts for cable entry and exit, Combi climate Cable Glands of IP 66/ IP 67/69 for cable entry and Grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 kA, C Curve Overload and Short Circuit protection, terminals as bus terminals for cable with necessary fixing arrangements and with cable glands, complete. |
| 83 | M&L for Earthing complete with galvanized earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32x 6 mm (up to 7.5m in length from earth plate) by means of brass bolts and nuts checknuts and washers of brass all as specified and shown in electrical plate no 3 of SSR part 1 including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with CI Cover 10mm thick Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel, 40 mm dia light grade pipe for protection of earth electrode and 20mm dia pipe medium grade for watering complete. |
| 84 | M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure as directed. |
| 85 | LIGHTENING PROTECTION |
| 86 | Supply and fixing Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screws including provision of30 cmx25cmx8cm sheet metal box made out of 3.15 m thick CRCA sheet with front hinged door shutter & locking arrangementand duly painted with two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and as directed. |
| 87 | M&L for Earthing complete with galvanized earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32x 6 mm (up to 7.5m in length from earth plate) by means of brass bolts and nuts checknuts and washers of brass all as specified and shown in electrical plate no 3 of SSR part 1 including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with CI Cover 10mm thick Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel, 40 mm dia light grade pipe for protection of earth electrode and 20mm dia pipe medium grade for watering all as specified and directed and tested on completion. |
| 88 | Fire fighting System |
| 89 | Supply and fix branch pipe with nozzle of 20 mm dia for hose reel conforming to IS 8090 all as specified and directed. |
| 90 | Supply and install Fire Extinguisher CO2 Type light weight squeeze grip type confirming to IS:15683 of capacity 4.5 Kg all as specified and directed. Note: (1) Fire extinguisher should equipped with hose of appropriate size and open-close should be with the help of wheel type valve.(2) Fixing arrangement to wall will be included in the quoted rates. |
| 91 | supply and install Fire Extinguisher Dry chemical powder ABC Type confirming to IS:15683 of capacity 6.0 Kg all as specified and directed.Note: (1) Fire extinguisher should equipped with hose of appropriate size and open-close should be with the help of wheel type valve.(2) Fixing arrangement to wall will be included in the quoted rates. |
| 92 | Supply and install Fire Extinguisher Mechanical Foam Type confirming to IS: 15683 of capacity 9.0litres all as specified and directed. Note: (1) Fire extinguisher should equipped with hose of appropriate size and open-close should be with the help of wheel type valve.(2) Fixing arrangement to wall will be included in the quoted rates. |
| 93 | M&L for Earthing complete with galvanized earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32x 6 mm (up to 7.5m in length from earth plate) by means of brass bolts and nuts checknuts and washers of brass all as specified and shown in electrical plate no 3 of SSR part 1 including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with CI Cover 10mm thick Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel, 40 mm dia light grade pipe for protection of earth electrode and 20mm dia pipe medium grade for watering all as specified and directed and tested on completion. |
| 94 | Fire Alarm & Detection System |
| 95 | Supply and fix 2 core 1.5 sqmm FRLS armoured copper cable as per IS:1554to wall/ roof/ false ceiling/ floors with necessary clamps/ saddles all as specified and as directed. |
| 96 | LIFT |
| 97 | Supply, design & install testing & commissioning passengers lift of capacity 8 passenger lift (544 Kgs capacity)in the adjusting lift well, speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS-14665, suitable to serve 08 floors (G + 7) upper floors with AC Variable Voltage & Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) complete all as specified. |
| 98 | All as per Srl Item No. 58 here-in-before but suitable to carry 13 passengers (884 Kg) at a speed of 1.5 M/sec to serve upto 08 floors (G+7 floors). |
| 99 | Aviation Light |
| 100 | Supply and fix aviation obstruction light LED type 10 Wattincluding standard fixing arrangements complete. |
| 101 | Supply and fix cable PVC insulated armouredPVC sheathed LT 1100 V grade with copper conductor of size 3 core 2.5 sqmm multi stranded conductor laid in ground fixed to wall roof etc with suitable clamps spacers bolts nuts etc complete. |
| 102 | Supply and fix time switches 250 V single Phase of 25 Amp rating with contactor fitted inside steel enclosure complete all as specified and directed. |
| 103 | DG SET |
| 104 | Supply, installation, testing and commissioning of Silent engine generating set with acoustic enclosure as per latest CPCB norms 415 volts 40 kVA 3 phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator including acoustic enclosure suitable for ambient condition and conforming to condition under IS 4722, BS 5514/ 2613 /5000 with and including the following:- |
| 105 | (i) The capacity of Generator set shall be net after all due de-rating factors as per relevant ISI design |
| 106 | (ii) Rate quoted shall be deemed to be inclusive of cable and terminations form Generator to the AMF Panel, with necessary holes to wall including making good to disturbed surfaces so as to match with the existing finishes all as specified and directed. |
| 107 | (iii) The quoted rate shall be deemed to be inclusive of first fill of oil and final successful acceptance test |
| 108 | (A) Alternator :-Standard design alternator rated at 40 KVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC,3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class \"H\" and voltage regulation of+/- 1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in +/- 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS - 2613/5000/ IS – 4722 |
| 109 | i) Insulation class - \"H‘ |
| 110 | ii) Temperature rise Class - \"H‘iii) Excitation : Self Excitediv) Regulation performance: The voltage is kept constant with +/- 1%, manual voltage adjustment within +/- 5%v) Frequency regulation +/- 1% |
| 111 | (B) Diesel Engine: - Adequate capacity of Diesel engine as accosted by the accepting officer basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under |
| 112 | i)Fly wheel with housing |
| 113 | ii) Cooling system :- Moulded radiator with fan & beltsiii) Cooling Water pump : - Centrifugal type belt driveniv) Exhaust System :- Exhaust System complete with exhaust piping of 150mm dia with MS pipe light grade upto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure.Exhaust gas turbo charger type. Exhaust manifoldSilencer : Residual type Bellows |
| 114 | v) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters,Fuel hoses.vi) Lub oil System : Lubricating oil filter Lubricating oil pump |
| 115 | vii) Air Intake System :Air intake ManifoldAir cleaner dry typeviii) Governor :- Electronic Governorix) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator |
| 116 | x) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length fromself starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and Starter gear ring Start and stop push button, Ignition key / SwitchHandling and operation : Salient features of accessories shall be as under: |
| 117 | Radiator with blower fanCorrosion inhibitor coolantPaper element filters for fuel, lub oil and by passElectronic governor controlled direct fuel injection systemFly wheel housing and fly wheel |
| 118 | xi) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or as per standardpractice ignition key switch and start / stop arrangement, indications for Engine parameters, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant temperature indicator, Battery volt display. |
| 119 | xii) Safety Controls : - Engine low lube oil pressure high water temperature and over speeding of engine |
| 120 | xiii) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling |
| 121 | xiv) Accessories :- AVM Pads built in enclosure and for entire unit on platform.xv) Base Frame : - Should be provided as OEM norms |
| 122 | xvi) MS pipe line to and from the fuel tank to the DG Set |
| 123 | C) AMF Panel :- Factory made inbuilt type control cubical type made out of 2mm thick CRCA sheet dust and vermin proof totally enclosed with front opening of 415 volts 3 -phase4 - wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 40 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 volts grade of suitable capacity, fuses, name plates consisting of 4 pole MCCBs and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, kW, kWH, pf, temperature, Battery voltage, etc |
| 124 | g) Annunciation with indication lamps for : (i) Low lub oil pressure.(ii) High Water Temperature. |
| 125 | (iii) Engine over speed. (iv) Battery low voltage |
| 126 | Controls :-a) Load on Indicationb) Load off indicationc) Engine start push buttond) Engine stop push buttone) Fault accept / reset push button |
| 127 | f)Battery charger(i) Transformer shall be dry type, double wound, with copper conductor andClass–B insulation with temperature rise limited to Class-A insulation.(ii) Isolating switch shall be heavy duty, load break type, operated by an externalhandle.(iii). Fuses shall be HRC type and arranged for easy replacement. Semiconductingdevices fuses shall be fast-acting type.(iv). Indicating meters (voltmeter and ammeter) shall be 96mm x 96mm, flush type90 degree scale with antiglare glass, + 1% accuracy with zero adjuster on thefront of the meter.(v.) The following indications/alarm annunciation shall be provided:a) Failure of input AC supply to the chargerb) Low battery voltagec) DC output fuse blownd) Charger faile) Over voltagef) Earth faultg) Battery on boost charge directed. |
| 128 | (v) DC Ammeter(vi) Charger rate selector switch |
| 129 | D) Acoustic Enclosure:-Manufactured by OEM suitable for 40 KVA DG Set(i) NAL approved as per latest CPCB norms(ii) It Should be as per latest rules and regulations of Ministry of Environment andPollution control board |
| 130 | (iii) The generating setbatteries and control panel should be inside the enclosure.(iv) Construction Details/specification are as follows:a) Outer body :- CRCA Sheet of 1.6mm thick b) Doors :- CRCA sheet of 1.6 mm thick c) Sound Insulation :- As per OEM Norms |
| 131 | v) The acoustic should be composite in construction and fully assembled integral unit |
| 132 | vi) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulatedplat form |
| 133 | vii) The DG Set should be provided with external Emergency stop push buttonviii) The enclosure should be suitably illuminated by CFL/FTL Lamp fittings.ix) The noise level should be 75 dba at 1m under free field conditions. |
| 134 | x) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set Green. The base frame should be painted with epoxy based black shade |
| 135 | E) The coated rate includes excavation, removing of soft soil and PCC, Cement Concrete foundation, filling and mass concrete type B2 (1:2:4) using 40 mm graded aggregate of size not less than 4.6 x 3.0 x 0.8 m for placing of DG Setcomplete all as specified and directed. |
| 136 | Material and Labour for earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead strip of 32 X 6 mm dia by means of bolts, nuts, check nutsand washers of galvanised iron or steel usinggalvanised iron strip 32×6mm and 50 mm dia light grade GI pipe upto test point or 7.5 mtr and GI pipe 20 mm medium grade for watering pipeas earthing lead all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion. all as specified and as directed. |
| 137 | TV & Telephone |
| 138 | Supply and fix GI metal flush boxes 1/2 module |
| 139 | Supply and fix telephone sockets(Jack type) RJ 11-1 with shutter 1 module with cover plate complete. |
| 140 | Supply and fix TV co-axial socket 1 module with cover plate complete. |
| 141 | Hot Water supply |
| 142 | Supply, install, testing and commissioning of storage water heater/geyser 25 Ltrs capacity complete with inlet and outlet pipe with all standard fittings and fixing accessories for fixing to wall including making electrical & water line connections and necessary civil work and complying with the following specification:- |
| 143 | Type:- Vertical |
| 144 | capacity of Inner tank:- 25 Ltrs |
| 145 | Colour:- White |
| 146 | Temperature sensitive LED indicator |
| 147 | Feather touch digital temp control |
| 148 | Shock proof 3 pin plug. |
| 149 | Upto 8 bar pressure resistance inner tank |
| 150 | Multifunctional safety valve. |
| 151 | IPX4chnology to protect electrical parts from water splash. |
| 152 | Earth leakage current breaker to cut off power immediately in case of current leakage and protect user from electric shocks. |
| 153 | Tank: Made with ultra thick super cold rolled steel plates dry powder coating finish and energy saving high density PUF insulation. |
| 154 | Heating element:- Glass coated heating element with resistant to oxidation and carbonation at high temperature of capacity 2000 W capacity. |
| 155 | Heavy duty magnesium anode rod with steel core to protect enamelled tank from rust and corrosion 230 V, single phase, 50 Hz AC power supply 5 star energysaving rating with BEE level. |
| 156 | Electric Chimney |
| 157 | Supply, fixing, testing and commissioning of Electric Chimney for kitchen, stainless steel sheet auto clean filter less, easy oil collection, heat auto clean with LED lamps, motion sensor control with digital display 60 cm, 1200 m3/hr airflow along with chimney installation kit, 3 meters length 15 cm diameter with expandable aluminium duct pipe upto 3.04 meters, 15 cm cowl cover, 2 U-shaped clamps and 2 meter adhesive aluminium tapeall as specified and directed. |
| 158 | Supply and fix 20 Amps SPN MCB metallic Plug & Socket all as specified and as directed. |
| 159 | Arboriculture |
| 160 | Supply & Planting carpet Grass by piece turfing including preparation of ground upto 30 cm deep and filling soft soil, cow dung and watering etc complete (loose soil and cow dung will measured separately) by the Engr-in-charge |
| 161 | Supply only approved loose soil best quality for plantation |
| 162 | Supply only approved vermi compost best quality |
| 163 | Supply only approved manure(cow dung) best quality |
| 164 | Supply and plantation of Foxtail Palm (height of plant not less than 2.0m above ground level) incl preparation of ground up to 30cm deep and filling of good earth, cow dung vermi compost and watering etc complete all as directed by the Engineer-in-charge. |
| 165 | All as per Srl Item No. 75 here-in-before but for Jamun of height not less than 1.50m |
| 166 | All as per Srl Item No.75here-in-before but for Mango tree of height not less than 1.50m |
| 167 | All as per Srl Item No. 75 here-in-before but for Jackfruittree of height not less than 1.50m |
| 168 | Supply, fixing, testing and commissioning sprinklers complete all as specified and as directed |
| 169 | M&L for Maintenance of the plants and grass planted in above items by weeding hosing saucer melding once in every 15 days, planting new plants/grass of same species and height without any extra cost to the department and as directed by the Engineer-in-charge complete for the period of maintenance period of Two years. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail