| 1 | General note applicable to all sections : 1) Only sieved river sand/crushed stone sand confirming to Zone-II from Godavari river or Varaha river orVamsadhara river or Sarada river or Nagavali river / Crushed stone sand shall be used as fine aggregate and Graded hard broken granite metalof 3 stage (VSI) material shall be used as coarse aggregate in relevant items. Specification for fine and coarse aggregate shall confirm to IS:383 (latest revision)2) In view of limit on water-cement ratio for durability requirements in design mix concrete, concrete admixtures (Carboxylate based superplasticizers of makes as per annexure B of section VII or equivalent) can be used after taking prior approval of Engineer-in-Charge and the rates quoted for concrete items shall be inclusive of the cost of admixtures, Design mix, trial mixes, testing (at site & at approved labs), etc. complete. 3) Thecontractor shall set up sufficient number of self loading mobile concrete mixers inside the project area for the production of concrete.4) Contractor may also be allowed to procure concrete from prior approved RMC plants on prior approval of the BARC subject to maintain required slump at site during pouring.To that extent suitable Mix Design should be carried out with required retention period. No extra payment will be made if concrete is brought from RMC plants outside the project area. |
| 2 | 5) Manufacturer\"s Test certificate of cement which is procured fromdealer/company is to be submitted for all cement related works by the contractor.6) \"Substrcture\" referes to the part of structure upto top level of ground floor grade slaband\"Superstructure\"refers to the part of structure above the top of the ground floor grade slab.7) The Scope of works which are not included in any specific items but indicated in the document \"General Scope of all works\" shall be within the scope of overall contract works. The cost of work/item/material indicated in this document shall be deemed to be included in the quoted rates of all individual items. |
| 3 | 9) The quoted rates shall include necessary royalties, seigneiorage charges,etc. and all other charges to supply all the required construction materials.10) For all standards and code of practices, specifications, like Indian Standard, MORT&H, ASTM, etc. refer onlylatest revisionsincluding all applicable amendments, revisions and additional publications (during contract period) and these have to be followed. 11)Prior approval for source of all construction materials by submission ofrelavent test certificates, documents, invoices etc. have to be taken from BARC. 12) All the tests mentioned in Quality Assurance Plan(QAP) should be carried out without any extra cost.13) The contractor has to submit all royalty /seigneiorage slips,etcfor all the naturally available construction materials before submitting the RA bills. |
| 4 | Note : The rate quoted for earth work excavation by contractor is deemed to have included the following points (a) to (j)a) removal of all kinds of vegetation, small shrubs, light/heavy jungle, trees etc., alongwith roots, including disposal/stack in the identified location. b) shoring, strutting, stepping, dressing, grading requiredfor keeping the earth in position on sides of trenches with approved timber/steel accessories wherever necessary to prevent sides from falling including bailing or pumping out of water if necessary including removal of debris/unserviceable materials and excavated excess soil, if any.c) dewatering of both ground and surface water, including removal of slurry generated while excavation and keeping the area free from water, to be let out of the building area through proper pipes & channels if required by suitable pumps,d) watering, ramming and thoroughly consolidate the bottom of all excavations & ground before the construction of foundation/footing/plinth beam, filling in basement or other work is commenced. |
| 5 | e) the loose pockets shall be excavated and compacted after back filling as directed by Engineer-in-charge, as per detailed specification and conforming to safety rules during progress of the work. f) Contour levels to be taken jointly with the Engineer-in-charge and prior written approval be taken before starting any excavation/ filling at every 3 m grids for arriving at the actual quantity,g) Backfilling will be done in layers of thickness as specified below.h) Cost inclusive of necessary royalties, seigneiorage charges and other charges to supply all the required construction materials, i) cost of items shall include all labour charges, hire charges of machinery, lubricants, fuels and tests etc.j) Measurement/Payment will be reststicted to PCC/drawing dimensions only. |
| 6 | Dismantling work |
| 7 | Dismantling doors, windows and clear storey openings (steel / wood) shutter including chowkhats, architraves, holdfasts etc.complete and stacking within 100 m lead (full windows) Of area 3.00 Sq.M and below |
| 8 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 100 m lead For thickness of tiles above 10 mm and up to 25 mm |
| 9 | Dismantling cement asbestos, Celotax or other hard board ceiling or partiton walls including stacking of serviceable materials and disposal of unserviceable materilas within 100 m lead |
| 10 | Demolishing C.C / R.C.C works by mechanical means and stock piling at designated locations carefully with out damaging adjacentstructures and disposal of dismantled materials up to a lead of 100 m, stacking serviceable and unserviceable materials separately including cutting reinforcement bars all as directed at site. |
| 11 | Dismantling brick work in Cement mortar carefully without damaging adjacent structures including stacking of materials anddispoal of unserviceable materials within 100 m lead as per direction of Engineer-in-charge |
| 12 | Masonary, Plasteringand Concrete Works |
| 13 | Note for Brick masonary works :a) Reinforcement will be measured & paid for separately under relevant item.b) RCC band and formwork shall not be measured seperatly, however no deductions will be made in brickwork for the same.c) No holes in brickwall will be allowed for scaffolding. Only double tubular steel scaffolding be allowed.Note for flyash bricks:In the fly ash bricks the mix confirming to the strength mentioned in the respective items shall be got approved by the department. The mix shall consist of ordinary portland cement content of not less than 20%(preferably) of the mixture consisting of Fly ash, OPC and Gypsum or any variation in proportion of design mix shall be submitted to BARC for approval. The Anhydraous Gypsum, Fly Ash, Cement, Crusher dust and other materials shall confirm to the the relevant IS codes. The Anhydrous Gypsum shall be procured from a reputed source approved by the department. Roller mixer shall be used for good homogeneous mixing. |
| 14 | Providing and constructing 100/150/200/230mm (or as directed) thick masonry in Super structure at all elevations with approved quality Fly ash/ FAL-Gbricks having minimum crushing strength 60 Kgs/Sq.cm and water absorption of maximum 20%, in cement mortar 1:4 (1 cement : 4 river sand/ crushed stone sand) uniformly mixed in machine with approved \"non-shrinking compound\"as per manufacturer’s instruction in specified courses of approved bond also providing horizonatal RCC band of 100/150/200mm x 100 mm (or as directed) at about 1.00 m c/c with 2 nos. 8 mm dia Tor bars and 6 mm dia links at 300 mm c/c in cement concrete (1:2:4), required formwork, complete including pointing,raking out joints, curing, cleaning, including independent double legged scaffolding, at all heights, depths and leads, dewatering area where required etc., all as per typical drawings, Technical specifications and as directed by the Engineer-in-charge.(Reinforcement and Shuttering shall be paid saperately in releavent item.) |
| 15 | Providing and fixing in position 22 gauge G. I. Chicken wire mesh with 20 mm opening, around door & window frames, junctions of walls with concrete etc. wherever required, before plastering including cutting, nailing with \"U\" nails, screwing, minimum overlapping of 150 mm, etc. all complete all as per drawings and specifications and as directed by Enginner-in-charge. (Overlaps will not be measured for payment) Width of chicken wire mesh to be fixed shall be min. 150 mm. |
| 16 | Providing 15 mm thick Internal plaster in cement mortar 1:4 without cement punning (using Crushed Sand) finished smooth, including sieving of sand to required fineness, preparation of the surface, scaffolding, curing all as per specifications, drawings and as directed at site complete. |
| 17 | Providing and laying in position Reinforced Cement Concrete (RCC) of grade M-30 using 20mm maximum size aggregates and crushed sand of approved quality including admixtures of approved brand and quality (plasticiser or super plasticiser) if required, including weigh batching, mechanical mixing, transporting, placing, vibrating, consolidation, finishing, curing etc. complete but excluding the cost of centering, shuttering and reinforcement complete as per specifications up to Plinth Level. |
| 18 | Providing Reinforcement Steel for reinforced cement concrete at all levels including supplying, preparation of bar bending schedules, cutting, bending, transporting, fixing, tieing in position with PVC coated G.I binding wire, all labour charges, cost of cover blocks in specified grade of concrete etc. complete as per specifications and drawings.Using TMT bars of specified grades of all sizes. TMT bars to be supplied by the contractor from the own plants of makes for guidance to bidders only using virgin materials |
| 19 | Providing and fixing at all levels, precast members using cement concrete 1:2:4 (1 cement, 2 crushed sand, 4 graded stone aggregate of max. size 20 mm) in, copings and / or bed blocks, plain window sills, shelves, louvers, steps, staircases, trench covers, drain covers etc. including hoisting and setting in position with C.M 1:3 (using crushed sand) cost of required centering, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 (using Crushed sand) on exposed surfaces complete as per specifications at all levels |
| 20 | Providing and laying in position cement concrete of 1:3:6 (1 cement, 3 crushed sand, 6 graded stone aggregate of maximum size 20 mm) including consolidation, finishing, curing etc. complete as per specificationsand drawings but excluding the cost of Form work shuttering, centering Complete at all levels |
| 21 | Providing and laying in position cement concrete of 1:2:4 (1 cement, 2 crushed sand, 4 graded stone aggregate of nominal size 20 mm) including consolidation, finishing, curing etc. complete as per specification and drawings but excluding the cost of Formworkshuttering, centering and steel reinforcement at all Levels |
| 22 | Providing, supplying and fixing 98 mm overall thick partition using Gypsteel Ultra™ stud partition which includes one layer of taperededge 13mm thick Gyproc® Duraline (conforming to BS 5234 –1992, Part 2) is screw fixed with drywall screws of 25mm at 300mm centres to either side of 70mm Gypsteel Ultra™ C stud (0.5mm thick having one flange of 34mm and another flange of 36mm made of GI steel) placed at 600mm centre to centre in 72mm Gypsteel Ultra™ floor and ceiling channel (0.5mm thick have equal flanges of 32mm made of GI steel), which is anchored to the floor & true ceiling using suitable anchor fasteners or metal screws with nylon plugs. The boards are to be fixed to the frame work with joints staggered to avoid leakage through joints. A gypsteel fixing channel of 99mm width (0.9mm thick having two flanges of 9.5mm each) has to beprovided at the horizontal joints of the two boards screw fixed to the studs using metal to metal flat head screws. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with gyproc jointing compound, Gyproc joint paper tape and two coats of drywall top coat (as per recommended practices of M/s SaintGobain Gyproc India). 25mm glasswool slab of density of 32Kg/cu.m shall be placed in the cavity |
| 23 | Providing , centering ,shuttering Form work using PVC film faced plywood in Super Structure to get a neat form finish surface for all types of structures including necessary strutting, proping, staging, supports etc and deshuttering the same after the specified time all as per drawings, specifications and as directed by the Engineer-in-charge at all levelsNote: 1) This item is applicable for all PCC and RCC structural elements like footings, beams, columns, slabs, lintels, chajjas, walls etc., for all shapes, heights and leads. 2) Only steel scaffolding, staging, supporting system to the formwork and steel frame work will have to be used for all RCC structural elements. 3) All surfaces adjacent to EPs, etc., shall be in true line and level & irregularities, if any, shall be rounded by mechanical grinding, chiseling, finishing the same using epoxy silica sand mortar (makes for guidance to bidders as per annexure B of section VII) at no extra payment. |
| 24 | Providing Structural steel work in M.S Plain Plates and chequrred Plates for Embedded Parts, Trench Covers, Connection plates etc.including cutting, hoisting, fixing in position and applying a priming coat of approved zinc chromate steel primer etc.including cost of structural steel Plates, welding all labour charges etc. complete as per drawings and specifications and as directed by Engineer INcharge.All test reports to be provided along with the supply of the materials |
| 25 | Floor Finish |
| 26 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS 15622 of approved quality shade and colour of size ranging from 300 - 600 mm long and 300 mm - 600 mm wide and thickness not less than 6 mm as approved by Engineer-incharge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (using crushed sand), setting the tiles in cement slurry and pointing the joints with matching colour Tile grout of approved quality of matching shade including using PVC tile trim in the exposed corners, complete as per drawings, patterns and specifications complete as directed by the Engineer-in-charge. |
| 27 | Providing and fixing 1st quality ceramic glazed floor tiles of minimum 300 - 600 mm long and 300 - 600 mm wide and thickness not less than 6 mm conforming to IS 15622 of approved quality in all colours and shades as approved by Engineer-incharge over a bed of 20 mm thick bed of cement mortar 1:4 (using crushed sand) and jointing with grey cement slurry including pointing with white cement based Tile grout of approved quality and matching shade complete as per patterns, drawings and specifications complete as directed by the Enginner-in-charge |
| 28 | Providing and fixing (Satin/Satin Matt finish/glossy) full body VITRIFIED tiles not less than 600mmx600mmx 8mm thick for flooring/ Skirting of approved quality conforming to IS 15622 of approved colour and shade laid over a bed of minimum 20mm thick bed of cement mortar 1:4 (using coarse river sand/ crushed stone sand) make a total thick ness of 30mm including thickness of tile. Cost including hacking, cleaning and preparing the surface for bedding, spreading neat cement slurry prior to bedding, fully buttering cement paste on back, fixing to required line, level,including chasing the walls to obtain the desired projection for fixing of skirting tile,joints to be cleaned and grouted with matching colour of approved qualityecement based Tile Grout (if required epoxy filling), curing, cleaning, etc. complete as per patterns, drawings and as per Technical specifications and as directed by Engineer-in-charge. |
| 29 | Grouting the joints of flooring tiles of size 600x600mm having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 30 | Providing, supplying and laying pre polished granite slab flooring / dado/ Door Jamb/ Sill / Wall cladding with not less than 17 mm thick granite slabs Using approved shades other than black over 20 mm thick base cement mortar 1:4 (using crushed sand) laid and placed with grey cement slurry including filling the joints with matching white cement based tile grout complete all as per specifications and drawings. |
| 31 | Providing and laying flooring using Welspun make Stone Polymer composite, \"Click-N-Lock Floor tiles\" of Wel-Lock technology over existing flooring of any type having proper level and strong base, as per the manufacturers specifications complete as detailed below: 1. Type of floor tiles: Welspun Click-N-Lock Tiles2. Category of design: Aristo collection3. Finish: Wood4. Size: 8.86\" * 48.03\" (or any approved size)5. Thickness: 5 mm with 1 mm IXPE Cushion backingThe flooring shall be laid/fixed completely as per the manufacturers specifications including skirting of 100 mm height, using suitable beading, reducer/T Mouldings etc. to the satisfaction of Engineer In charge. The cost of flooring includes cost of all materials, transportation, labour charges for laying, all taxes, electricity etc complete. |
| 32 | Providing and applying white cement based wall putty of approved quality over concrete or Plastered surface up to 3 mm thick to getuniform surface free from undulation including cleaning complete all as directed by the Engineer-in-charge |
| 33 | Providing and applying wall painting two coats on new workwith premium plastic emulsion paint of approved brand to give an even shade, including a coat of approved cement primer, including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge |
| 34 | Providing , painting and finishing walls with two coats of exterior emulusion paint On rough cast Plaster surfacesof approved quality on sand face plaster/ plain plaster & concrete of required shade over new work including base coat of water proofing cement paint, preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge. |
| 35 | Providing and laying water proofing treatment in sunken portions of WCs, bath rooms etc. by appying cement slurry mixed with waterproofing cement compound consisting of applying: (a) 1st layer of slurry of cement @ 0.488 kg / sq.m mixed with water proofing cement compound @ 0.253 kg per sq.m. including injecting cemnt slurry .This layer will be allowed to air cure for 4 hours. (b) 2nd layer of slurry of cement @ 0.242 kg / sq.m mixed with water proofing cement compound @ 0.126 kg / sq.m. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with cement slurry. Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (using crushed sand) admixed with proprietary water proofing compound conforming to relevant IS and approved by Engineer-in-charge including mixing \"RECRON 3S\" fibre at the rate of 125 grams per 50 kg of cement in top layer of plaster and finally finishing the surface with trowel with neat cement slury in bottom and all the sides of sunken portion. complete as directed by the Enginer-in-charge. The treatment to be tested for water tightness before filling the sunken areas. |
| 36 | Providing and Laying cement concrete 1:2:4 in super structure (1 cement, 2 crushed sand, 4 aggregates 20 mm to 40 mm) for filling sunken floors of toilet bath & kitchen admixed with proprietary water proofing compound as per manufacturer\"s specifications and approved by Engineer-in-charge including scaffolding, consolidation, finishing curing etc. |
| 37 | JOINERY & METAL WORK |
| 38 | Providing Second class teak wood work in frames of doors, windows, clear story openings and other frames, wrought framed and fixed in position of required size and shape including sawing, jointing,making rebates for shutters, making grooves as shown in the drawings, finishing the surfaces to the required finish all as per specifications and drawings including necessary MS hold fasts 40 mm X 3 mm thick, 200 mm long / with coach screws including protective painting to the suface that will come in contact with walls, joining materials, labour etc. complete all as per specifications and as directed by the Engineer-in-charge |
| 39 | Providing and fixing 35 mm thick flush door shutters conforming to IS : 2202 non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with internal teak wood lipping 25mm wide and fixing with 4 Nos of 125 mm long Stainless steel Hinges with S.S. wood screws complete. |
| 40 | Providing and fixing decorative high pressure 1.0 mm thick laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS:2046 Type S including cost of adhesive, labour etc. complete as directed |
| 41 | Providing Melamine polishing on wood work (one coat) as per manufacturers instructions, matt or glossy finish as specified including preparation of the surfaces, complete. as per specifications and as directed by the Engineer-in-charge |
| 42 | Providing and fixing fully flush type Hollow metal Steel door including frame and shutter at all levels. Pressed Galvanized steel conforming to IS 277, Single / Double / Triple/Quadruple leaved approved quality which consists of frame, shutter, infill and finish as detailed below :Door frame shall be single rebate profile of size 100 x 57 mm with bending radius of 1.2 mm having 1.60 mm thick galvanized steel sheet (16 gauge). Steel door shutter of 46 mm thick, fully flush, double skin door shall be manufactured from 1.20 mm thick galvanized steel sheet (18 gauge). The stile edges to be lock seamed with no weld marks. The infill material shall be resin bonded honey comb Kraft paper with thermal insulation. Door frames and shutter shall be finished with etched primer coating, stoved zinc phosphate primer (35 microns DFT) and thermosetting polyurethane aliphtic grade paint (35 micron DFT) of approved colour. Rate shall include all joints of frames with provision for anchor fastner fixing to wall / RCC surface, PUF filling in the frame , reinforcement pad for fixing of hydraulic door closers, aldrops, tower bolts factory finish, provision for slots for mortise locks, for pre-punched cut outs to receive hardwares and iron mongery, 3 mm thick hinge plates predrilled to receive hinges for screw mounted fixing, provision for vision pannel, louvers, access control system,fixing back plate for provision of door stopper, complete all as per specifications, manufacture’s specification and as directed by Engineer-in-charge. Measurementand payment of hydraulic door closers, aldrops, tower bolts, vision panels, louvers, hinges, handles, locks, and access control system shall done in the relavant items.Note: Wherever steel louvers are provided on the door, the corresponding area of louvers area will be deducted from the measurement of hollow metal steel door area. |
| 43 | Providing and fixing factory made 30 mm thick single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 44 | Providing and fixing factory made Frame size 50 x 100 mm single extruded WPC (Wood Polymer Composite) solid door/window/clerestory windows & desertory other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 45 | Providing and fixing pair of stainless steel \"D\" type door handles 10mmdia, 250mm long SS304grade solid rod,of specified size in steel doors/wooden doors including screws/bolts etc.all as per drawings and specifications complete |
| 46 | Providing and fixing aluminium hanging heavy quality floor door stopper ISI marked with twin rubber stoppers, anodised transparent or dyed to required. colour or shade with necessary screws etc. complete. |
| 47 | Providing and fixing Stainless steel double ball bearing butt hinges of size 100 x 75 x 3 mm thick for hollow steel door of approved quality complete as per specifications, drawings and as directed by Engineer-in-charge. (For hollow metal doors & fire doors indicated in the schedule elsewhere) |
| 48 | Providing , supplying and fixing bright Finished / Stainless steel finish Brass Aldrop of size 300 X 14 mm of approved quality and design including C.P BRASS / SS screws and Bolting from rear side including required no of \"Kuntis\" etc complete all as per specifications, drawings and as directed by Engineer-in-charge. (For hollow metal doors & fire doors indicated in the schedule elsewhere) |
| 49 | Providing and fixing stainless steel tower bolts of size 300 X 12 mm of approved quality with necessary screws etc. all as per specifications and as per drawings. |
| 50 | Providing and fixing IS: 3564 marked aluminium die cast body tubular type universal hydraulic door closer of approved quality with necessary accessories and screws etc. in wooden doors / steel doors with necessary bolts & nuts complete as per specifications and as directed by the Engineer-in-charge |
| 51 | ALUMINIUM WORKS, (GLAZING, etc., ALUMINIUM PARTITIONS, DOORS, WINDOWS, LOUVERS, WALL SPANS) |
| 52 | GENERAL NOTE FOR ALL ITEMS UNDER THIS SECTION: 1. The rate quoted shall include submission of all designs, engineering & shop drawings for approval from BARC. The procurement and fabrication shall be done only after approval of the design and drawing by BARC.2. The quoted rate shall include all wastage,Taxes, duties, statutory obligations and safety code compliance as directed by Engineer-in-charge. |
| 53 | Providing and fixing Anodized (Colour anodizing), Aluminium sections (Minimum anodizing thickness of 15 micron) work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / Z sections and other sections of approved quality conforming to IS 733 and IS 1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically whereever required including cleat angle, aluminium snap beading for glazing / panelling, C.P brass / stainless screws all complete as per drawings and and directions of Engineer-in-charge including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required filling the gaps using silicon grout sealent etc. (fittings glazing and panelling shall be paid for separately) |
| 54 | Note :1) Only anodized aluminium sections, aluminum beading, aluminium sheets & aluminium handles used will be measured for payment. The rate quoted is deemed to have included the cost of allbrass concealed tower bolts, screws, gasket, weather strips, PVC lining, etc. and no seperate measurement / payment will be made for the same.2) Glass, particle boards, aluminium grills, brass mesh, louvers, etc. will be measured & paid separately under relevant items.3) All fittings shall be of matching colour anodised of aluminium sections. 4) A long M.S. Rodat both ends to be provided in all aluminium shutters in top & bottom horizontal members internally connecting vertical members and fixed with M.S. washers and nuts. No measurement and payment shall be made for this.5) Aluminium Frames to be fixed with walls / columns with minimum 100 mm long Brass screws / Stainless steel screwsand necessary hold fasts. For fixing of frames with RCC members,for Aluminium windows/louvers, doors having area of equal to 10 sq.m or above, Carbon steel zinc cozted \"HILTI\" make anchor fasteners shall be used. No measurement and payment shall be made for these items.6) All aluminium frame and shutters Joints shall be of mitred joints with necessary cleats/ plates . 7) Filling the gap between aluminium frame & adjacent RCC / Brick work / Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete up to 5 mm depth and 5 mm width. |
| 55 | Providing and fixing glazing With clear float glass panes of 5.00 mm thicknessin aluminium doors, window, ventilator shutters and partitions etccomplete as per the architectural drawings and directions of the Engineer-in-charge(Cost of snap beading, PVC / Neoprene gasket etc shall be paid in basic item) Note: Glass shall be measured as per inner dimensions of the aluminium frame sections to which the glass is fixed. |
| 56 | PLUMBING WORKS |
| 57 | Providing and fixing in position star white glazed vitreous Extended Wall Hung European Water Closet of with \"P\" or \"S\" trap of approved quality & colour, 6/3 dual flush cistern including all internal parts of the cistern, plastic solid seat & cover of heavy quality with rubber buffers and flap, heavy quality flush bend, CP bolts and nuts, 15mm dia concealed CP angle cock valve with heavy quality reinforced 600 mm longPVC inlet connection pipe all of approved quality, CP wall flanges whereever required. The EWC shall be fastened with threaded bolt M12 for ceramics fastening with 4 adjustable fastening brackets with fastening materials including 100 mm dia. C.I. connector pipe from P or S trap to the junction of the soil stack or drain, including testing, commissioning & cleaning, etc.all complete as per specifications and as directed by Engineer-in-charge. |
| 58 | Providing and fixing PVC rain water pipes/ Sewer pipes of conforming to relevant IS type B and PVC SWR fittings & specials conforming to relevant IS including jointing with seal ring / With PVC solvent adhesive including fixing in walls using clamps etc complete all as per drawings, specifications and as directed by the Engineer-in-charge |
| 59 | SWR PIPE 90 mm O/D |
| 60 | SWR PIPE 110 mm O/D |
| 61 | Providing and fixing viterious China wash basin of approved quality and colour with C.I. brackets, 15 m C.P. brass pillar tap ofapproved quality,15 mm x 600mm long PVC Inlet connection, 32 mm heavy quality C.P. brass waste coupling of standard pattern,including painting of fittings and brackets, cutting and making good the walls and testing complete all as per specifications and as directed by the Engineer-in-charg |
| 62 | White vitreous China wash basin size 630 x4 450 mm and equivalent sizes with single 15 mm C.P. brass pillar tap |
| 63 | Providing and fixing heavy quality CP brass bottle trap 31 / 32 mm of approved quality single piece moulded with height of 270mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal,of approved quality for wash basins / urinal etc all as per specifications and directed by the Engineer in charge. |
| 64 | Providing and fixing in position 15 mm CP Health faucet makes for guidance to bidders along with CP Brass 2 in 1 Bib cock and Angle cock of suggested make as per annexure B of section VII with necessary flexible hose upto 1500 mm long using teflon tape, CP wall bracket, CP nozzle, CP wall flanges, etc., complete.Note : All fittings shall besuggested make or equivalent model as per annexure B of section VII |
| 65 | Providing and fixing 6mm thick mirrors of size 600x450 mm ofsuggested make fixed to walls with C.P.brass screws and concealed washers complete. all as per specifications and as directed by the Engineer-in-charge |
| 66 | Providing and fixing PVC Nahani trapof self cleaning design of 100 mm inlet and 75 mm outlet,jointing with solution with the connection pipes, placing as per the drawings, embedding in Cement concrete 1:2:4 and making circular hole up to floor level using 110 mm O/D PVC pipes of 6 Kg/sq.cm pressure and fixing 1 No. 125 mm dia PVC openable grating, complete all as per drawings and specifications and as directed by the Engineer-in-Charge. |
| 67 | Providing and fixing in position best quality CP Twin coat hook of approved quality as per annexure B of section VII with SS screws, etc. complete. |
| 68 | Providing and fixing S.S Towel ring of approved quality complete fixed to walls with 30 mm CP brass screws with concealed fitting arrangement all as directed by the Engineer-incharge. |
| 69 | Providing and fixing C.P brass towel rail of approved quality 600 mm long complete fixed to walls with 30 mm CP brass screws with concealed fitting arrangement all as directed by the Engineer-incharge. |
| 70 | Providing and fixing 15 mm dia long body C.P brass bib cock of heavy quality of approved quality as per specifications and as directed by the Engineer-in-charge |
| 71 | Providing and fixing heavy quality stainless steel/C.P brass grating of approved equvalen tmake as specified for floor traps/nahani traps all as directed by the Engineer-in-charge |
| 72 | Providing and fixing 15 mm C.P brass tube 600 mm long with nuts and washers complete for wash basins / urinals with all necessary acessories complete as directed by the Engineer-in-charge |
| 73 | Providing and fixing S.S Toilet Paper roll holdersuggested make complete fixed to walls with 30 mm CP brass screws with concealed fitting arrangement all as directed by the project engineer |
| 74 | Providing and fixing 15 mm C.P brass 2 in 1 bib cock and Angle cock combination of Heavy Quality as per specifications and as directed by the Engineer-in-charge |
| 75 | Providing and fixing 15 mm CP brass Angle stop cock ofsuggested make- quarter Turn C.P brass Angle cock of heavy quality, for wash basin inlet / flush cistern etc. as per specifications and as directed by the Engineer-in-charge |
| 76 | Providing and fixing 40mm Heavy qualityFlexible PVC waste pipe (Semi rigid or Flexible) 1200mm legth with fittings of suggested makefor sink or wash basin including PVC waste fittings etc. complete all asper specifications and as directed by the Engineer-in-Charge |
| 77 | Providing and fixing Gunmetal (GM) Gate valve of Leader or equivalent model of approved quality with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type, etc. complete. |
| 78 | i) 25 mm dia (Screwed ends) |
| 79 | ii) 40 mm dia (Screwed ends) |
| 80 | Providing, Laying, jointing, fixing and testing Heavy quality(C-Class)Galvanised Iron pipes and ISI marked fittings like, tees, elbows, bends, unions, nipples, reducers etc.as required for the work, including testing the pipes and fittings for 10.00Kg/Sq.Cm hydralic pressure with aminimum period of two hours duration with clean water,including cutting,threading,jointing with hemp yarn,white lead, jointing Teflon tape,exposed/concealed by chasing walls and making good by filling with concrete 1:3:6, complete all as per specifications and drawings, including two coats of anticorrosive bitumastic paint for all concealed lines/two coats of synthetic enamel paint for all exposed lines all as directed by the Engineer-in-charge.Pipes with exclusive use ofsuggested make C-Class pipes. |
| 81 | 15 mm dia |
| 82 | 25mm dia |
| 83 | 40 mm dia |
| 84 | Providing and fixing Chlorinated PVC (CPVC) pipes having thermal stability for hot & cold water supply (as ASTM Standard 2846 & SDR - 11 Grade) including all CPVC Plain & Brass threaded fittings, fixing the pipe with clamps including chasing the walls, concealing the pipes and making good the same etc. This includeds jointing of pipes & fittings with CPVC Solvent cement & testing the joints complete all as per specifications, drawings and as directed by the Project Engineer |
| 85 | 50 mm outer dia CPVC pipe (Concealed) |
| 86 | Providing and fixing 15 mm C.P brass pillar cock of heavy Quality and specied type as per specifications and as directed by the Engineer-in-charge. |
| 87 | Making connection of distribution branch with G.I. MainUpto 40 mm dia. pipes by providing and fixing tee including cutting and threading the pipes etc. complete as per specifications and as directed by the Engineer-in-charge. |
| 88 | Providing and Fixing CP brass 100 mm dia shower rose with Shower arm of Specified make as per specifications and as directed by Engineer-in-charge complete |
| 89 | Providing and fixing 15 mm nominal dia CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. |
| 90 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brassbrackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 91 | False cealing |
| 92 | Providing and Fixing AEROLITE False Ceiling- tiles- Cosmos / Spintone / Hexa /Quadra Models in position Suspended false ceiling system using 600 x 600mm Calcium Silicate Ceiling tiles (AEROLITE ceiling systems) Tiles having 15mm densified edges and 100% humidity resistance, incombustible as per BS476 part IV with thermal conductivity of 0.043 w/m KC and approvred surface design and edge profile (TEGULAR/ SPINTONE) placed in a suspended grid of size of 600 x 600mm made of hot-dipped G.I steel sections having an exposed surface capping of pre-finished baked polyester painted coil wherein the main tee of size 24mm x 38mm x 0.33mm shall be suspended at 1200 mm centres along the length of ceiling with 4mm dia G.I wire with necessary level adjusters and cross tees of size 24 x 28 x 0.33mm x 1200 mm shall be inserted in to slots between the main tees at 600mm centres and thereafter in direction vertical to the longer tees, cross tees of size 24 x 28 x 0.33mm x 600mm shall be inserted to form a grid size of 600 x 600 mm resting on the perifery walls on wall angles of size 20mm x 20mm x 3000 mm x 0.40 mm thickness. The rate shall include providing necessary openings for light fixtures, diffusers, trap doors etc to be made as per layout drawings. The work shall be carried out as per directions of Engineer-in-charge. The main tees to be suspended from the ceiling/ soffit with the help of matal dash fastners of 6mmx50mm, soffit clits of 25mmx35xxx1.60mm and 4mm dia G.I wire with galvanised spring steel levelling clips. the entire grid system shall be designed to bear a distributed load of minimum 15 kg/Sq.m (Only calcium silicate false ceiling area will be measured for the purpose of payment) |
| 93 | Providing and fixing in position suspended seamless false ceiling system using 12.50 mm thick moisture resistant plain gypsum board of suggested make suspended ceiling, which includes Gypsteel ULTRA™ CRP surface ribbed perimeter channels (having one flange of 20mm and another flange of 30mm and a web of 27mm) along the perimeter of ceiling, screw fixed to brick wall/partition with the help of nylon sleeves and screws, at 610mm centres. Then suspending Gypsteel ULTRA™ CRP surface ribbed intermediate channels of size 45mm (with two flanges of 15mm each) from the soffit at 1220mm centres withGypsteel ULTRA™ CRP surface ribbed ceiling angle of width 25mmx10mm fixed to soffit with GI cleat and steel expansion fasteners (Mfg by Ms Saint Gobain Gyproc).Gypsteel ULTRA™ CRP surface ribbed Ceiling section of having web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the Gypsteel ULTRA™ intermediate channel with the help of connecting clip and in direction perpendicular to the Gypsteel intermediate™ channel at 457.5mm centres. Single layer of 12.5mm tapered edge Gyproc® MR (conforming to BS 1230 part 1) is then screw fixed to ceiling section with 25mm drywall screws at 230mm centres. Screw fixing is done mechanically either withscrew driver or drilling machine with suitable attachment. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Gyproc jointing compound, Gyproc joint paper tape and two coats of drywall top coat (as per recommended practices of M/s Saint- Gobain Gyproc India) |
| 94 | ELECTRICAL |
| 95 | Supply & Installation of 25mm dia MMS PVC conduit on wall/beam/ structure |
| 96 | Supply & Installation of 32 mm dia MMS PVC conduit on wall/beam/ structure |
| 97 | Supply and Installation of 25x12 mm PVC casing/caping on wall/beam/ structure |
| 98 | Supply & Installation of DLP PVC Trunking on wall/ beam/ structureof minimum 85*50mm with all the necessary accessories like bends, flat junctions, flat angles, internal angles,external angles,wall crossing accessory end capsetc |
| 99 | Supply & installation of Trunking End caps for existing Trunking |
| 100 | Supply & Installation of 6M metal(GI) flush box on wallas per technical documents and as directed by the engineering in charge |
| 101 | Supply & Installation of 3M metal (GI) flush box on wallaas per technical documents and as directed by the engineering in charge |
| 102 | Supply & Installation of 2M metal( GI) flush box on wall as per technical documents and as directed by the engineering in charge |
| 103 | Supply , installation of2 M/3MPVCSurface Box |
| 104 | Supply & installation of 4 M PVCSurface Box |
| 105 | Supply & installation of 6 M PVCSurface Box |
| 106 | Supply, Installation, Testing and Commissioning of 12/18-way SPN flush/ surface mounted Distribution Board on wall /structure |
| 107 | Supply, Installation, Testing and Commissioning of 24-way SPNflush /surfacemounted Distribution Board on wall /structure |
| 108 | Supply, Installation, Testing and Commissioning of 6-WAY TPNDouble Door AC Distribution Board on wall /structure |
| 109 | upply, Installation, Testing and Commissioning of 4-way 7 segment per phase isolation, flush mounted Distribution Board on wall /structure |
| 110 | Extension of light/fan/ power point wiring with 3 nos. 1.5 sq.mm FRLS PVCwires in existing conduit/ casing capping. |
| 111 | Extension of power wiring with 3 nos. 2.5 sq.mm FRLS PVCwires in PVC conduit/ casing capping. |
| 112 | Extension of powerwiring with 3 nos. 4 sq.mm FRLS PVCwires in PVC conduit/ casing capping. |
| 113 | Extension of power supply/ points with FRLS type4 sq mm 3 core flexiblecopper cable |
| 114 | Extension of power supply/pointswith FRLS type 2.5 sq mm 3 core flexibleLT cable with copper conductor . |
| 115 | Supply & Installation of Modular wiring devices 16A switch with indication (1 Way) |
| 116 | Supply & Installation of Modular wiring devices 25A switch with indication (2M, 1 Way) |
| 117 | Supply & Installation of Modular wiring devices6/10Aswitch(1 Way) |
| 118 | Supply & Installation of Modular wiring devices 10Aswitch (2 Way) |
| 119 | Supply & Installation of Modular wiring devices 6/16A socket |
| 120 | Supply & Installation of Modular wiring devices 20/25A socket |
| 121 | Supply,Installation, Testing and Commissioning of 20A/25A AC Starter switch with start and stop in existing concealed modular box . |
| 122 | Supply & Installation of Modular wiring devices Fan regulator(2 Module)for existing fans |
| 123 | Supply & Installation of 3 Pin plug top 16A |
| 124 | Supply & Installation of 3 Pin plug top 6A |
| 125 | Supply &installationof Ceiling Roses for connection ofexisting lights/ fans . |
| 126 | Supply & Installation of cover plate & frame for 6 Module |
| 127 | Supply & Installation of cover plate & frame for 3 Module |
| 128 | Supply & Installation of cover plate & frame for 2 Module |
| 129 | Supply, Installation ofHeavy duty double D-Hook with fastener for ceiling. |
| 130 | Supply & installation of 1200mm sweep, BLDC Ceiling Fan with suitabledown rod and supportive wire |
| 131 | Supply, Installation and commissioning of 400 mm sweep, type Wall mounted Fanwith metal blades |
| 132 | Supply, Installation, Testing and Commissioning of 230 mm sweep diameter metal Exhaust Fan including connecting cable and plugtops |
| 133 | Supply & installation of Call bells |
| 134 | Supply & installing of Wall mounted type Hand dryer forhand wash area |
| 135 | Supply, installation 4P 63 A,10 kA,Type C, MCB |
| 136 | Supply, installation DP 63A,30 mA RCCB |
| 137 | Supply, installation DP 32A/40A,30 mA RCCB |
| 138 | Supply, installation DP 63A, 10 kA,Type C, MCB |
| 139 | Supply, installation DP 32A/40A, 10 kA,Type C, MCB |
| 140 | Supply, installation SP 16A,10 kA,Type C, MCB |
| 141 | Supply, installation SP 20A,10 kA,Type C,MCB |
| 142 | Supply, installation SP 10A,10 kA,Type C,MCB |
| 143 | Supply, installation Dummy covers for switches/DB |
| 144 | Supply, installation Testing and Commissioning of 4 kV, 40 kA,4PType 2 Surge diverter, in existing distibution boards |
| 145 | Supply, Installation, Testing and Commissioning of 100 W, Outdoor, LED type Flood lights forbuilding security lighting |
| 146 | Supply, Installation, Testing and Commissioning of minimum 40W(minimum 4000 lumen and 100 lumen/watt) LED lighting fixture, Recess mounted( 2 feet x 2 feet) |
| 147 | Supply, Installation, Testing and Commissioning of minimum 40W(minimum 4000 lumen and 100 lumen/watt) LED lighting fixture, Surface mounted( 2 feet x 2 feet) |
| 148 | Supply & installation of wall-mounted/modular type 2/ 3 W LED Bed light |
| 149 | Supply & installation of 11/10 W LED Surface mounted Mirror lighting fixture |
| 150 | Supply, Installation, Testing and Commissioning of minimum 15W (minimum 100 lumen/watt)LED lighting fixture , Recess mounted, Circular shape |
| 151 | Supply, Installation, Testing and Commissioning of Surface Mounted minimum 20W/24W(minimum 100 lumen/watt).LEDlights.(1 feetX1 feet) |
| 152 | Supply and installation ofceiling mountedtype chandelier/ jhoomerlights ,Warm type LED (32W or above) for VIP dining area |
| 153 | Supply andreplacementofInsect Killer MachinewithUVtubes Bug Zapper, Fly Catcher |
| 154 | Supply, Installation, Testing and Commissioning of PIR Motion Sensor |
| 155 | Supply, Installation, Testing and Commissioning of 4C X 16 Sqmm XLPE, Copper armoured cable on tray /wall/trench |
| 156 | Cable end terminations of 4C X16 Sqmm, XLPE, Copper cable including double compressed gland(brass) & Heavy duty long barrel crimping type copper lugs |
| 157 | Supply and Installation of MS item like angels/channels/ plates as per site requirement etc for supporing cable trays/ electrical items, includingfabrication, welding, fixing with anchor fastener, protection of MS item with anti corrosion and two coat of black paint. |
| 158 | Supply, Installation, Testing and Commisioning of Earth pits with600mm X 600mm X 6mm Copper plate as per IS: 3043, earth excavation min. to a depth of 3.6 metres from ground level in all types of soils including charcoal, salt, brick masonary chamber, white wash, cast iron hinged cover & testing of earth resistance values, marking earth resistance values on the earth pit chamber. |
| 159 | Supply and Installation of\"25 mm X 6mm\"hot dipped GI Flat earth strip with clamps at every 1.5 metre distance along with all accessories oncable tray/wall / structure with insulatorsto panels/ motors/ Earth pits |
| 160 | Supply, Installlation of 8 SWG copperconductor for earthing |
| 161 | Manual Earth excavation for under ground cable/ trench/ pits |
| 162 | Brick protection for the underground cable including sand, warning tape as per SLD |
| 163 | Supply and Installation of dia 50 mm HDPE Pipes for laying of LT cables |
| 164 | Supply, Installation of Steel flexible conduit of dia 25mmfor DB terminations |
| 165 | Supply and Installation of Electrical insulating rubber mats for electrical safety at Panels/ Motors |
| 166 | Supply and Installation ofMulti-lingual Danger Stickers |
| 167 | Supply and Installation of Fire Extinguishers (1 Set consisting of CO2 - 1 No., DCP - 1 No.) of Capacity weight 4.5kgs |
| 168 | Supply and inatallation of3L instant geysor including suitable valves , connecting flexiblesteel pipes etc and as directed by the engineering in charge |
| 169 | Supply, Installation, Testing and Commissioning of10 kVA,50Hz, 3 phase on-line, double conversion UPS with 45 min Battery backup, external SMF batteries, battery rack and necessary cables, and 4P MCB. Warranty: Minimum Two year OEM warranty shall be applied for both UPS and batteries |
| 170 | Supply and Installation of rigid Photo luminescent Signage boards to be suspended from ceiling/wall, surface mounted of size 150mmX400mm (Non powered) to be visible from 15 metres such that it will give accurate guidance to the employees and as directed by the engineering in charge |
| 171 | Cat-6 UTP cable: Supply, installation,testing and commissioning of Cat-6 UTP cable. Installation of cable shall be in PVC conduit and surface/ concealed conduit and as directed by the engineering in charge |
| 172 | Two pair Telephone cable: Supply, installation, testing and commissioning of 0.5mm annealed bare copper conductor, two pair with PVC insulated telephone cable.Installation of cable shall be in surface/ concealed conduit and as directed by the engineering in charge |
| 173 | RJ11Telephone Socket module: Supply and installation of RJ11 single module suitable for installing in standard modular boxes and as directed by the engineering in charge |
| 174 | RJ45 Computer Socket module: Supply and installation of RJ45 Cat 6 Computer socket single module suitable for installing in standard modular boxes .as directed by the engineering in charge |
| 175 | TV point wiring of cable television point in guest house rooms or common area including outlet boxes and cover plates, outlet socket sockets as directed by the engineering in charge |
| 176 | MECHANICAL |
| 177 | SIT&C of split ac of 1.5 Tr capacity, 5 star rating as per following specification:Cooling capacity in TR : 1.5 TR, Inverter type.Rating as per ISEER: 5 starCoil material : Copper with protective blue fin anti corrosioncoatingRated voltage: 230 V, Single phase, 50 HzRefrigereant:R32 / R410A / R-134A / R290 / R600ACasing and capping made of pvc: complete covering ofrefrigerant pipe between ID & OD units with casing and capping made ofPVC. Stabilizer : 230V, 50 Hz suitable for 1.5 TR AC.Supply & Installation of 16 Amps plug top,Supply and installation of Split AC outdoor stand andSupply and fixing of AC Line PVC self adhesive tape (white roll), extra copper tubing and core cutting is also in the scope of work and as directed by EIC . |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail