PROPOSED CONSTRUCTION OF NAGAR NIGAM EMPLOYEE RESIDENCE AT MATHURA (UP).-EXCAVATION WORK Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil Diluting and injecting chemical emulsion for postconstructionai anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With chlorpyriphos/lindane E.c. 20% with 1% concentration Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. Excavating, supplying, stacking and filling of local earth including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. PCC WORK Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources). Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand (zone-iii) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) REINFORCEMENT CEMENT CONCRETE Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland Slag cement, admixtures in recommended proportions as per iS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping concrete to site of laying, curing, carriage for all leads; excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; the following grades of concrete. Note: Extra cement up 10% of the minimum specified cement content in design shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M25 grade with minimum cement content of 330 kg /cum All works upto plinth level Up to Plinth Lvl. All works above plinth level upto floor V level concrete of M25 grade with minimum cement content of 330 kg /cum Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. Cement concrete prepared with batch mixing machine Extra for providing and mixing hardening compound of approved quality as per manufacturers specification in cement concrete. Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) SHUTTERING Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick Centering and shuttering including strutting, propping etc. and removal of form for Shelves (cast in situ) Centering and shuttering including strutting, propping etc. and removal of form for Weather shed, chajjas, corbels etc., including edges Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick Centering and shuttering including strutting, propping etc. and removal of form forEdges of slabs and breaks in floors and walls Under 20 cm wide Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof ( plan area to be measured). Suspended floors, roofs, landings, beams and balconies (Plan area to be measured) REINFORCEMENT & MS WORK Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. thermo-mechanically treated bars of grade fe-500D or more. Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). BRICK WORK Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar I:4 (l cement : 4 coarse sand) Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade- 1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). Half brick masonry with non modular fly ash bricks of class designation 10, conformingio IS :12894, in super structure above plinth upto floor V level. Cement mortar 1 : 4 (1 cement : 4 coarse sand) FINISHING WORK 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. Surface Preparation - Exterior surface cleaning / Sanding using recommended tools. Home Sheild Waterproof Putty – Applying 2 coat of the HS Waterproof Putty is a premium quality white cement-based putty that is damp proof and has some unique properties ,Cured surface after waterproofing with wall putty provides excellent hydrophobicity, exhibiting “Lotus Bead” effect Damp Stop Duo Primer - Applying 1 coat of HomeShield Dampstop Duo primer using a Graco sprayer is a fast and efficient way to get a smooth, even base coat. it is a specially formulated premium quality acrylic primer with superior alkali, damp and efflorescence resistance properties both from positive and negative sides of the wall. Long lasting waterproofing warranty of 7 years on Exterior wall application & 2 years on Interior wall application (T&C applied) Exterior with Longlife 10- Applying 2 coats of Long Life 10 Luxury Exterior paint using a Graco sprayer luxury highperformance exterior emulsion specifically formulated for long-lasting protection and aesthetic enhancement of external surfaces. This product features advanced PU Silicon Technology, offering superior performance under extreme weather conditions and upto 40% dilution on suitably primed/basecoat applied or painted internal walls and ceilings by roller, brush or spray as per manufacturers recommendations. Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour complete to achieve even shade and colour : New work two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work Providing and applying 2.5 mm thick road marking strips retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications. FLOORING WORK Providing and laying vitrified floor tiles in different sizes thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 cement : 2 stone dust) admixed with pigment to match theshade of stone and pointing with same mortar. . Red sand stone. Providing and laying Vitrified tiles in floor in different sizes thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm includingngrouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm Providing and laying full Body Vertified Tiles in Skirting riser steps of 600x600mm sizes (thickness 9mm) with water absorption less than 0.08% and confirming to IS: 15622, approved brand manufacture, in desired colour and shades, laid with cement based high polymer modified quit set tile adhesive (water based) confirming to IS :15477, including grouting of joints. All complete as per direction E/I (Matt Finish/Glossy) Providing and laying Polished Granite stone flooring required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average) thick base of cement mortar 1:4 (1 cement coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer- Charge. Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent Stone tile work for wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3 cement : 3 coarse sand), including pointing in white cement with and admixture of pigment to match the stone shade. 8mm thick (mirror polished and machine cut edge) Granite stone of any colour and shade Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1: 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red Area of slab upto 0.50 sqm Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge give high gloss finish etc. complete as per design approved by Engineer-in-Charge. (Granite work) Extra for providing opening of required size & shape wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 cement : 4 coarse sand) : 25 mm thick Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. Marble stone flooring with 18 mm thick marble stone, per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with Makrana white second quality DOOR AND WINDOW Providing and fixing factory made single extruded WPC Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions plus side shall be acceptable but no extra payment on this account shall be made. Frame size 65 x 100 mm Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorativetype, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains cross bands and face veneers on both faces of shutters. mm thick including ISI marked Stainless Steel butt hinges with necessary screws Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. Copper oxidised as per IS 1378) 75x47x1.70 mm Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured). Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick Providing and fixing 1mm thick M.S. sheet door with frame 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :250x10 mm Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R3 series with frame (55mm & above) x 40mm & above) & sash (30mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on every panel along with multi-point locking system (Height upto 1.8m). Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R3 series with frame (98mm & above) x (40mm & above) & both glazed and fly screen sash (30mm & above) (55mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height upto 1.8m) Casement window single panel with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles. Using R3 series with frame (55mm & above ) x (45mm & above) & sash 55mm & above) x 65mm & above). (Height upto 1.8 metre) Fixed window / ventilator without mullion / transom. Using R1 series with frame (33mm & above ) x (35mm & above). (Height upto 0.90 metre) Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture withmatching wood beading ROOF WORK Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multichambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.40 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in- Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 – Part 3 (ii) Sites with structure height more than 20m for all wind speeds Providing and laying water proofing treatment to vertical horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 wide and pasted to each other with bitumen @ 1.7 sqm). Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of selfhealing of cracks up to a width of 0.50mm. The work shall carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. vertical surface two coats @ 0.70 kg per sqm per coat horizontal surface one coat @1.10 kg per sqm. Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase Providing and laying integral cement base water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc. consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm ofcement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC slab adjoining wall upto mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken brick bats 25mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved Engineer-in-charge to required slope and treating similarly the adjoining heights upto 300mm height including rounding of junctions of walls and slabs. (c) After two days propoer curing applying a second of cement slurry using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed water proofing compound conforming to IS 2645 and approved by Engineer in charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300 x 300 square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test . All above operations to done in order and as directed and specified by the Engineer-in-charge with average thickness of 120 mm and minimum thickness at khurra as 86mm Making khurras 45x45 cm with average minimum thickness 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : graded stone aggregate of 20 mm nominal size) over V.C. sheet 1 m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat neat cement, rounding the edges, making and finishing the outlet complete. Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler (110 mm ) Single pushfit Coupler (110 mm ) Single tee with door (110x110x110 mm) Single tee without door 110x110x110 mm Bend 87.5°, 110 mm bend Shoe (Plain) 110 mm Shoe Supply and fixing of Door lock Providing and fixing looking mirror superior glass Tappered edge ( approved quality) 6 mm thick fixed on Spacers on Back Side complete in all respect as per direction of Engineer in- charge. looking Mirror Size( 0.60 M x 0.75M) looking Mirror Size( 0.45 M x 0.60M) F long body Kitchen bib cock Jaquar (600 mm)model no. CHR-347 Complete in all respect as per direction of engineer incharge. (Quotation Rate) F of Fitting (Jaquar/ Plumber make) Complete in all respect as per direction of engineer incharge. (Quotation Rate) Pillar Cock model no.CHR-15001 Bib cock model no. CHR-35037 Providing and fixing brass Door fifting with lacured polish including labour T&P Complete in all Respect. Quotation Rate) Door bell big round- 4 Small round 2 Handle 900 mm Handle 600 mm Sliding rod 610 mm Aldrop 24 Aldrop 18 Total Cost of Building Providing and fixing water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Make: Jaquar (FLSWHT- 5353PPZ Rimless Bowl with Cistern For Extended Wall Hung WC with PP Soft Close Seat cover, Hinges, Dual Flush Cistern Fitting, Accessories Set, Size: 380x650x730 mm) Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests Providing and fixing wash basin with C.I. brackets, 15 mm P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single mm C.P.brass pillar tap Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe mm dia Providing and fixing 100 mm sand cast Iron grating for gully trap. Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 100 mm nominal dia Pipes 150 mm nominal dia Pipes Providing and fixing PVC pipe conforming to IS make working pressure 6kg/sqcm including testing labour T&P and all complete fittings 150mm dia 100mm dia Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm dia Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32mm dia Providing and fixing gun metal gate valve with C.I. wheel of approved quality {screwed end):. 32mm dia 32mm dia Providing and fixing brass bib cock of approved quality : 15 mm nominal bore Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore Providing and fixing brass stop cock of approved quality : 15 mm nominal bore Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter Providing and fixing CP Brass 32 mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Providing and fixing square-mouth S.W. gully trap class SP- 1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Providing and fixing 600x450 mm beveled edge mirror of superior glass (ofapproved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 15 mm nominal bore Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 610x460 mm bowl depth 200 mm Providing and fixing C.P. brass angle valve for Basin mixer and geyser points of approved quality conforming 8931 15mm nominal bore Providing and fixing PTMT soap Dish Holder having length 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. Total Cost of Plumbing Work-B