| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.All kinds of soil |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 3 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: |
| 4 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 5 | Providing and laying in position machine batched and machine mixeddesign mix M-25 grade cement concrete for reinforced cement concretework, using cement content as per approved design mix, includingpumping of concrete to site of laying but excluding the cost of centering,shuttering, finishing and reinforcement, including admixtures inrecommended proportions as per IS: 9103 to accelerate, retard settingof concrete, improve workability without impairing strength and durabilityas per direction of Engineer-in-charge.Concrete of M25 grade with minimum cement content of 330 kg /cum All works upto plinth level foundation |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. |
| 7 | Providing and laying in position machine batched and machine mixeddesign mix M-25 grade cement concrete for reinforced cement concretework, using cement content as per approved design mix, includingpumping of concrete to site of laying but excluding the cost of centering,shuttering, finishing and reinforcement, including admixtures inrecommended proportions as per IS: 9103 to accelerate, retard settingof concrete, improve workability without impairing strength and durabilityas per direction of Engineer-in-charge.Concrete of M25 grade with minimum cement content of 330 kg /cum All works above plinth level column |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for columns, etc. for mass concrete. |
| 9 | Providing and laying in position machine batched and machine mixeddesign mix M-25 grade cement concrete for reinforced cement concretework, using cement content as per approved design mix, includingpumping of concrete to site of laying but excluding the cost of centering,shuttering, finishing and reinforcement, including admixtures inrecommended proportions as per IS: 9103 to accelerate, retard settingof concrete, improve workability without impairing strength and durabilityas per direction of Engineer-in-charge.Concrete of M25 grade with minimum cement content of 330 kg /cum All works above plinth level Beam |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 11 | Providing and laying in position machine batched and machine mixeddesign mix M-25 grade cement concrete for reinforced cement concretework, using cement content as per approved design mix, includingpumping of concrete to site of laying but excluding the cost of centering,shuttering, finishing and reinforcement, including admixtures inrecommended proportions as per IS: 9103 to accelerate, retard settingof concrete, improve workability without impairing strength and durabilityas per direction of Engineer-in-charge.Concrete of M25 grade with minimum cement content of 330 kg /cum All works above plinth level Slab |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 13 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. (TMT Bars) Fe-500 |
| 14 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 15 | Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in |
| 16 | Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in superstructure above plinth level up to floorV level.Cement mortar 1:3 (1 cement :3 coarse sand) |
| 17 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) |
| 18 | 12 mm cement plaster on rough side of single or half brick wall of mix: 1:3 (1 cement: 6 coarse sand) |
| 19 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:3(1 cement: 3 coarse sand) |
| 20 | Providing and laying gang saw cut 18 mm thick, mirror polished premoulded and pre polished machine cut granite stone of required size andshape of approved shade, colour and texture in footpath, flooring in roadside plazas and similar locations, laid over 20 mm thick base of cementmortar 1:4 (1 cement : 4 coarse sand) including grouting the joints withwhite cement mixed with matching pigment, epoxy touch ups etc. completeas per direction of Engineer-in-Charge.With granite stone of all colour except black, cherry/ruby redof area less than 0.50 sqm. |
| 21 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 22 | Kota stone slab flooring over 20 mm (average) thick base laid over andjointed with grey cement slurry mixed with pigment to match the shadeof the slab, including rubbing and polishing complete with base of cementmortar 1 : 4 (1 cement : 4 coarse sand) : |
| 23 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colors, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 24 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone of size 12.5mm nominal size) laid in one layer finished with floating coat of neat cement (25mm thick floor) |
| 25 | S/F Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 26 | Providing and fixing angle iron frames for doors, windows and ventilator so f mild steel angle sections of size 35x35x5 mm, joints mitred andwelded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existingT-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steelprimer, all complete as per the direction of Engineer-In-charge |
| 27 | Providing and fixing angle iron frames for doors, windows and ventilator so f mild steel angle sections of size 35x35x5 mm, joints mitred andwelded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existingT-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steelprimer, all complete as per the direction of Engineer-In-charge |
| 28 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other,fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) Z Section |
| 29 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 30 | Providing and fixing in position collapsible steel shutters with verticalchannels 20x10x2 mm and braced with flat iron diagonals 20x5 mmsize, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm diasteel pulleys, complete with bolts, nuts, locking arrangement, stoppers,handles, including applying a priming coat of approved steel primer |
| 31 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick(a) Single leaf |
| 32 | Same as above & Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 33 | Providing & Fixing 1.00mm thick decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding uality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. |
| 34 | Providing and fixing glazing in aluminium door, window, ventilator shuttersand partitions etc. with EPDM rubber / neoprene gasket etc. complete asper the architectural drawings and the directions of engineer-in-charge With float glass panes of 4.0 mm thickness (weight not less than 10 kg/ sqm |
| 35 | Distempering with oil bound washable distemper of approved brandand manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 36 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) |
| 37 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete. |
| 38 | Providing and fixing ISI marked oxidised M.S. Sliding bolt black finish, (Barrel type) with necessary screws etc. complete : 300X16MM |
| 39 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 300X10MM |
| 40 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 200X10MM |
| 41 | Providing and fixing ISI marked oxidised M.S. handles 125MM |
| 42 | Providing and laying integral cement based water proofing treatmentincluding preparation of surface as required for treatment of roofs,balconies, terraces etc consisting of following operations: Applying a slurry coat of neat cement using 2.75 kg/sqm ofcement admixed with water proofing compound conformingto IS. 2645 and approved by Engineer-in-charge over the RCCslab including adjoining walls upto 300 mm height includingcleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm |
| 43 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75mm deep chase. |
| 44 | Painting with synthetic enamel paint of approved brand and manufactureof required colour to give an even shade : Two or more coats on new work over an under coat of suitableshade with ordinary paint of approved brand and manufacture |
| 45 | Construction of drain along with apron (150 X 150 MM) |
| 46 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 47 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 48 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require. White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tappillar tap. White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tappillar tap. Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. |
| 49 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. |
| 50 | a) 32mm dia |
| 51 | b) 40mm dia |
| 52 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 53 | Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge.15mm nominal bore |
| 54 | Providing and fixing CP Brass 32 mm size Bottal Trap of approved quality & make and as per the direction of Enginer-in-charge. |
| 55 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge |
| 56 | b) 100 mm nominal dia Pipes |
| 57 | c) 80 mm nominal dia Pipes |
| 58 | Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size). Including cost of cutting holes & making good the walls etc. |
| 59 | a) for 100mm dia pipe. |
| 60 | b) for 75mm dia pipe. |
| 61 | Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors.a) 100mm inlet & 75mm outlet. |
| 62 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes.a) 110mm diameter |
| 63 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.a) 110mm |
| 64 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.a) 110mm |
| 65 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 66 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall |
| 67 | a) 25 mm nominal dia Pipes |
| 68 | b) 32 mm nominal dia Pipes |
| 69 | c) 40 mm nominal dia Pipes |
| 70 | d) 50 mm nominal dia Pipes |
| 71 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c ixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc |
| 72 | a) 16mm dia nominal bore |
| 73 | b) 20mm dia nominal bore |
| 74 | Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. a) 15mm nominal bore |
| 75 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 a) 15mm nominal bore |
| 76 | Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. a) 15mm nominal bore |
| 77 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 a) 15mm nominal bore |
| 78 | Providing and fixing gun metal gate valve with wheel of approved quality. |
| 79 | b) 25mm dia nominal bore |
| 80 | c) 32mm dia nominal bore |
| 81 | d) 50mm dia nominal bore |
| 82 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete |
| 83 | a) 20 mm nominal bore |
| 84 | b) 25 mm nominal bore |
| 85 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.a) Circular Tank |
| 86 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. a) Pipes 80mm to 300mm diameter. |
| 87 | Providing and laying non-pressure NP2 class (light duty) R.C.C.pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : |
| 88 | a) 150mm diameter |
| 89 | b) 200mm diameter |
| 90 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. |
| 91 | a) 150mm diameter |
| 92 | b) 200mm diameter |
| 93 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75 |
| 94 | (i) For Sewer Line |
| 95 | Extra for depth of man hole size 90x80 cm |
| 96 | Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. |
| 97 | Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work) 50mm nominal bore. |
| 98 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 50mm |
| 99 | Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for sluice valve, with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :With F.P.S. bricks |
| 100 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :50 to 80 mm dia nominal bore |
| 101 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 102 | Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections butexcluding modular plate etc. as required. |
| 103 | 5/6 A switch |
| 104 | 3 pin 5/6 A socket outlet |
| 105 | Bell push |
| 106 | Supplying and fixing two module stepped type electronic fanregulator on the existing modular plate switch box includingconnections but excluding modular plate etc. as required. |
| 107 | Supplying and fixing modular blanking plate on the existingmodular plate & switch box excluding modular plate asrequired. |
| 108 | Supplying and fixing 3 pin, 5 A ceiling rose on the existingjunction box/ wooden block including connections etc. asrequired. (Mirror Light + Wall Fan + Ex. Fan) |
| 109 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 110 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 111 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 112 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 113 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 114 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 115 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 116 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 117 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 118 | Providing and fixing plain 16/0.20mm (0.50sqmm) twin flatflexible, FRLS PVC insulated, copper conductor cable, in PVCsleeve of suitable size on the floor/ wall, or side of the table/door etc. as required. |
| 119 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door |
| 120 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 121 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\"curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required. Single pole |
| 122 | Supplying and fixing single pole blanking plate in the existingMCB DB complete etc. as required. |
| 123 | Supplying and fixing 20 A, 240 V, SPN Industrial type socketoutlet, with 2 pole and earth, metal enclosed plug topalongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 124 | Supplying and fixing 30 A, 415 V, TPN Industrial type socketoutlet, with 4 pole and earth, metal enclosed plug topalongwith 30 A \"C\" curve, TPMCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 125 | Supply of water tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP 66 and above Protection . complete in all respect. |
| 126 | Supply of LED Tube Light batten fitting suitable for up to 1 X 12 watt LED tube Mirror light on surface complete in all respect. |
| 127 | Supply of round 15 Watt LED Down Lighter with heat sink, diffuser/ Reflector and driver set complete in all respect. |
| 128 | Supply of LED Tube Light with batten suitable for up to 1 X 20 watt LED tube light fitting including tube on Surface complete in all respect |
| 129 | Supply of Ceiling fan 1200mm sweep, 240V, ball bearing as approved by Engineer in charge complete in all respect. Please Enable Macros to View BoQ information |