}

Tender For Provision Of Office Building With Allied Infrastructure At Lkg Rr And Spl Repair To Bldg No P-36 (Jcos Living) At Bde Camp, Kg Top., Poonch-Jammu And Kashmir

Tender Notice

52593542
Tender For Provision Of Office Building With Allied Infrastructure At Lkg Rr And Spl Repair To Bldg No P-36 (Jcos Living) At Bde Camp, Kg Top.
Tender
Indian
Jammu And Kashmir
Poonch
29-12-2025

Tender Details

Tender For Provision Of Office Building With Allied Infrastructure At Lkg Rr And Spl Repair To Bldg No P-36 (Jcos Living) At Bde Camp, Kg Top.; 23 Supply and fixing in replacement LT over head lines on existing cable poles with XLPE insulated AB Cable 2x25 Sqmm and messenger of 1x25 sqmm including all joining kits, steel hook, insulator, suspension clamp, rubberinsert nut, bolts etc complete all as specified and direced. 24 Supply and fixing for 1X20 watt LED ceiling/wall mounted lighting fixture with lamp lumen not less than 2100 lumen polycarbonate, environemental friendly, energy effecieint fixedto wall/ceiling & connecting upto ceiling rose with three core twisted flexible 1.5 sqmm PVC copper conductor cable with earthing complete all as specified and as directed. 25 Supply and fixing energy efficientLED building security light fitting 35 W, input voltage 110V to 280VAC, 50 Hz with ingress protection IP66, LM 80, standard luminaries with efficiency 100 lumen/watt with secondary optics, perfectly matched lenses, complying to IEC60598/IS10322, with auto shut down on high voltage, CRI>70,PF>0.95, with short circuit & reverse circuit protection against10kV high surges, minimum 25000 burning hours (life), operating temperature 1 to 50 degree C, rectangular shape with pressure die cast aluminium housing with weather proof gasket for lamp and driver compartment with system wattage of 45W=10%W, rated lumens, 120 degree view angle, constant current type driver having THD<10%, including all fixing arrangement like clamps, nuts, bolts, washers, 35W LED rod lamp (having PF>0.9, input voltage 90-300V, IP-66, LM80) with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. complete all as specified and as directed. 26 Supply and fix GI bracket of 40 mm bore light grade pipe 1.2 m length bend to shape as required including 02 Nos of MS flat iron clamp, nut&bolt etc. complete all as specified and directed by EIC 27 Supply and fixing LED luminaire 600 mm x 600 mm, 36 watt, 220V AC recessed/ Surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holder & LED lamp suitable for roof ceiling including connecting upp with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. Note : Recessed & surface mounted lights shall be provided as per site requirement. 28 Lan/CCTV information socket- category 6-UTP -1 module complete all as specified and directed. 29 TV socket1 module complete all as specified and directed. 30 Supply and drawingpair of 0.5 sqmm FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/PVC conduit as required complete all as specified and directed. 31 Supply and drawing co-axial TV cable RG-6 grade, 0.7 mm. Solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheathed in the surface /recessed steel/ PVC conduit as required complete all as specified and directed. 32 Supply and drawing of UTP 4 pair CAT 6 LAN cable in thesurface/ recessed steel/ PVC conduit as required. 33 On site LLDPE septic tank designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 in foundation 150 mm thick, vent shaft, connection etc. complete for 05 users complete all as specified and directed. 34 Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including interceptiing chamber and screen chamber made of brick masonary in CM,RCC cover sla in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8M dia X 3.0 M effective depth complete all as specifiedand shown on drawing. 35 Schedule A Part XII (List of items of Works Pertains to Special Repair to Bldg No. P-36 (JCO living) at KG Top. 36 B/R Portion Demolition of cement concrete in any description complete all as specified and directed 37 Taking down cement plaster from brick walls hacking for keys & scrubbing down with water including raking out joints ,as in patches complete all as specified and directed. 38 15mm thick rendering in cement mortar 1:4 on brick work surface on wall,finished even & smooth without using extra cement including with WPCas per manufacturer,s instructions complete all as specified and directed. Note:- WPC shall be measured and paid seperately. 39 10mm thick rendering in cement mortar 1:6 on brick or concrete surface on wall including finishing surface even & smooth without using extra cement complete all as specified and directed. 40 5 mm thick rendering in CM 1:3 on fair faces of ceiling concrete surfaces, finished even andsmooth without using extra cement complete all as specified and directed. 41 Demolition of Brick work or stone/boulder masonry,built in Cement Mortar or cement lime mortar incl all quions, arches, pillars etc. complete all as specified and directed. 42 Brick work with old size bricksstraight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed 43 Cement concrete 1:2:4, type B1 using 20 mm graded stone agg as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, copings, kneelers, apex stones, bed plates, including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed. 44 50 mm thick cement concrete (1:3:6), type C-2 using 40mm graded stone aggregate as in floors, hard standing etc and laid in alternate bays complete and finished the even & fair and providings joints through out the thickness of plinth protection filed with mastic filling comprising one part of bitumen 85/25 grade and three part of sand by weight complete all as specified and directed 45 Preparing new plastered surface and applying three coat of white wash on ceilingcomplete all as specified and and directed 46 Applying two coats of cement base paint on walls over a coat of primer including preparation of new plastered or un-plastered surfaces of wall complete all as specified and as directed. 47 Preparation of old plastered surface of walland applying one coat of oil emulsion distemper of approved tintscomplete all as specified and directed by Engineer-in-Charge. 48 Preparation of newly plastered surfaces on walls and applying two coats of oil emulsion distemper over acoat of 1mm thick putty complete all as specified and directed. 49 Taking down Shutters of any description n exc 1 sq. m each complete all as specified and as directed. 50 Taking down Shutters of any description exc exc 1 sq. m and n exc 2 sq. m each complete all as specified and as directed. 51 Factory made second class hard wood plain framed panelled shutter (Two panel) with lock rail and pannel of 9mm thicks BWP commercial ply or 12mm veneered particle board with commercial vereered on both faces, the size of rails and style as per IS-1003 (Part-I) kiln seasond and chemically pressure treated, 35mm thick complete all as specified and directed. 52 Second class hard wood 35mm thick glazed and gauged skeleton shutter factory made without sash bars open rebated and prepared to receive glass/gauge etc. top, bottom and lock rail, styles, edges of framing champhered or rounded fitted with cut and mitered wooden beads for securing glass/gaugeetc; size of members of shutters supplied and fitted to chowkatscomplete all as specified and directed 53 Preparation of new wooden surfaces of any description, over 10cm in width or girth, not otherwise specified and applying two coats of synthetic enamel paint over one coat of pink primercomplete all as specified and as directed. 54 Preparation of old decorated wooden surfaces of any description, not otherwise described over 10cm width & girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. 55 140 mm longfloor door stopper of aluminium alloy body and tongue , anodised ,with hard drawn steel spring ,fixed in floor complete all as specified and directed 56 Mild steel ordinary rat tail rod pattern spring 300mm size including roller & roller plate and including welding complete all as specified and as directed. 57 Solid PVC door frame of size 50mmx47mm made out of 5mm single side prelam PVC sheet reinforced with ms square tube suppling and fixing in opening as per specification & drawing. 58 Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC C channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and double side prelam PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling for double side prelam PVC sheet to be fitted with M.S. frame welded/ sealed to the stile and rails feathered at edges with suitable PVC sheet beading, and jointed togethher with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified and directed. 59 Extrudedaluminum alloy handle fabricated type anodized, 150mm size complete all as specified and directed 60 Steel window/ ventilator glazed and gauged (combination) with side hung/ top hung shutters incl box type / projecting type hinges, and steel peg stay, handle & locking arrangement and frame made out of 1.25mm thick pressed steel frame complete incl necessary cooler arrangement in window & guard bars all as per sample kept at GE Office completeall as specified anddirected by Engr-in-Charge. 61 100mm size SS butt hinges and fixed to PVC frame /Wooden Frame and angle iron frame by necessary welding complete all as directed and as specified. 62 200mm long aluminium barrel towerboltsstove enamelledblack, with bright bolt and fixed complete all as specified and directed 63 Aluminum anodized barrel tower bolts extruded section, 150mm size complete all as specified and directed 64 Supply and fix in repair chromium platedswivel shower roses with or without swivel joints,for fixing with 15mm pipe fixedcomplete all as specified and as directed. 65 300 mm long aluminiumsliding door bolt, anodised,with hasp,staple(bolt type) and fixing clips of sheet,cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixedcomplete all as specified and as directed. 66 Taking up or down 15mm bore steel tubing & connection including cleaning for or removal from site complete all as specified andas directed. 67 Taking up or down 20mm bore steel tubing & connection including cleaning for or removal from site complete all as specified and as directed. 68 15mm bore tubes medium grade galvanized with all fittings such as Tee, elbows, sockets, unions, plugs, short lenghts etc. and fixed complete to walls and ceilings or laid in floors concealed or open of any length all as specified and directed by Engr-in-charge. 69 20 mm bore tubes medium grade galvanized with all fitting such as Tee, elbows, sockets, unions, plugs, short lenghts etc and fixed complete to walls and ceilings or laid in floors of any length all as specified and directed by Engr-in-charge. 70 Supply and fixing in repair brass CP wall mixer 2 in 1 with provisiion of overhead shower suitable for 15mm bore pipe complete all as specified and directed 71 Supply and fixing in repair 15mm dia Pillar taps,fancy type, cast copper alloy, with capstan heads, chromium plated,screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly-nuts,screwed for iron pipe and fixed as specified and directed. 72 Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar. 73 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. 74 Providing edge moulding to 18-20mm thick stone of counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete all as specified and directed. 75 Machine cut kota stone slab flooring 20-25mm thick over, laid over cement screed base , jointed and pointedwith grey cement slurry mixed with pigment over 20mm thick cement mortar 1:6 screed bed to match the shade of the slab including rubbing and polishing complete all as specified and directed.Note : Work will be in patches or in bulk 76 Machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar over 10 mm thickcement plaster 1:3jointed and pointed with grey cement slurry mxed with pigment to match the shade of the slab including rubbing and polishing complete, all as specified and as directed. 77 Supply and fix in repair vitreous china wash down water closet pan pedestal pattern white including connection in drain andin flushing pipe complete including P or S trap and including plastic water closet seat cover with flat bottom andMS Chromium plated hinge divicecomplete all as specified and as directed . 78 Supply and fix in repair High or low level PVC valveless, syphonic action type, flushing cistern, 10 ltr capacity, low level, white, with inlet, ball valve, float and handle including brackets and connections to pipes and fixing of chain and pull, or lever, if any as specified and as directed. 79 Supply and fix in repair health faucet (ABS) body mild steel chromium plated suitable for 15mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including making connections and fixed in positions complete in all respect as specified 80 Grating doom 125mm dia with waste hole of PTMT (minimum weight 40 gms) complete in all respect all as specified. 81 Toilet paper holder , CP, box type complete all as directed. 82 Supply and fix in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. 83 Supply and fix in repair tubular towel rail, brass cromium plated, 20mm dia, D type, 60cm long between flanges completeall as specified and directed Engrs-In Charge. 84 Supply and fix in repair 15 mm dia bib tap,fancy type chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed allasspecified and directed. 85 Supply and fix in repair, Stop valve/angle valve cast copper alloy, chromium plated with capstan head, screwed down, high pressure screwed both ends for 15 mm bore iron pipe or for unions and fixed in repair complete, all as specified. 86 Supply and fix in repair 15mm bore dia Concealed Stop valve , brass CP (fancy type, chromium plated withlong shank) screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified. 87 Supply and fix in repair Vitreous chinawash hand basin, whiteflat back, size 580 x 450 mm with brackets, including cutting for and pinning in ends of brackets or erecting stand all as specified and directed. 88 Supply and fix in repair 32 mm bore waste fittings, brass, chromium plated for sinks, basins etc with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete. 89 Supply and fix in repair PVC connection 15mm bore length not less than 450mm long with both ends PTMT nuts complete all as specified. 90 Preparation of new or previously untreated steel or iron surfaces of any description, not exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. 91 Preparation of old decorated steel surfaces of any description, not otherwise described over 10 Cm width & girth and applying one coat of synthetic enamel paint, complete all as specified and directed by Engineer-in-Charge. 92 Supply and fixing in repairs, Rotational moulded polyethylene water storage tanks of 500 Litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc complete all as spesified and directed . 93 Supply and fixing in repairs, 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as spesified and directed . 94 Supply and fixing in repairs 20 mm bore, Ball brass valves, high pressure, with polythene float and fly nuts complete, screwed for iron pipe or brass ferrule complete all as specified and directed. 95 Taking down exsting roof treatment of any description in any condition including removing of cement plaster of concrete of any description from the roof surfaces and removing all the debris to a distance n exc100m and roughening surfaces, sweeping clean and washing down with water toremove dust etc and applying evenly cement slurry at the rate of 3 kg/sqm over cleaned surfaces and providing 10mm thick cement screed in CM 1:4, finished surface even and smooth, after that cleaning the entire roof surface thoroughly to remove all loose particles, dust/dirt particles and applyingone coat of industiral bituminious primer at the rate of 0.40ltr /sqm over the plastered surfaces of roof and applying a coat of hot bitumen of grade 85/25 heating to working temperature of 180 Deg C @ 1.2kg/sqm then applying APP based polymericmembrane minimum weighing 3.60Kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt not less that 150 gms/sqm) laid with 75 mm side overlap and 150 mm overlap primed surfaces by forced application as per manufactures instructions and applying a coat of idustrial bitumen 85/25 grade @ 1.20Kg/sqm blinded with dry sand 0.50Kg/sqmcomplete all as specified and directed. 96 Supply and fixing in repair for PVC (SWR) pipes 110 mm single socketed, in any length with rubber ring joints, laid in trenches or in floors all as spd and directed. 97 Supply and fixing in repair for PVC (SWR) pipes 75 mm single socketed, in any length with rubber ring joints, laid in trenches or in floors all as spd and directed. 98 Supply and fixing in repair 110mm bore PVC (SWR) bends any radiusall as specified and directed. 99 Supply and fixing in repair 110mm bore PVC (SWR) branch piece, double (doubleY) equal or unequal all as specified and directed. 100 Supply and fixing in repair PVC floor trap with grating including jointing with solvent cement to waste pipe 75 mm dia. 101 Supply and fixing in repair 75mm bore PVC (SWR) bends any radius complete all as specified and directed. 102 Supply and fixing in repair 75mm bore PVC (SWR)vent cowl suitable for pipes complete all as specified and directed. 103 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.. 104 Glazed ceramic colouredtilesof size300x200x7mm / 450 mm x 350 mm x 7mm thick as in vertical surfaces , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick cement plaster in cement mortar 1:4 complete all as specified and directed. Shade/Colour of tile shall be approved by the GE. 105 25mm thick PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in sub base and flooring, etc.complete all as specified and directed. 106 Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including15mm thick screed bed in CM 1:6 complete all as specified and directed. 107 All as per Item 13.71 above but in skirting over 10mm thick rendering in CM 1:4 complete all as specified and directed. 108 ColouredNon Skid ceramic tiles 7 to 8mm thick (square/rectangular) are of each tile exc 0.11 Sqm but n.exc. 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with & incl 15mm thick screed bed or bedding layer with CM 1:6 complete all as specified and directed. 109 Supply and fix in repair Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane fixedcomplete all as specified. 110 E/M Portion 111 Taking down carefully copper/aluminium point wiring for light, bell socket power socket etc complete with boards, outlet boxes fittings and fixtures such as switchs, sockets, lamp holders bracket,ceiling rose, celing fan etc complete. complete all as specified and directed. 112 Point wiring with two single core, 1.5 Sqmm (nominal area) size multistranded copper conductor cable and one single core 1.5 sqmm (nominal area) sizecopper conductor cable, as earth continuity conductor connected to common earth dolly,1100 volts grade , FRLS, PVC insulated unsheathed cable in and including concealled PVC conduit of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, Bend, PVC Conduits for crossisng etc. complete with PVC terminals box for mounting switches, sockets, fan regulators etc for the followings points:- 113 One light/Fan point controlled by one switch complete all as specified and as directed. 114 One 5 pin, 6 A socket outlet on the independent board. Complete all as specified and directed. 115 One 5 pin, 6 A socket outlet on the same board complete all as specified and as directed. 116 One light point controlled by two numbers two way switches complete all as specified and as directed. 117 One bell point controlled by two way switches complete all as specified and directed. 118 All as per item No 14.02 here-in-before but with two 2.5 sqmm size cables as phase and neutraland one 2.5 sqmm size cable as earth continuity conductor for one 15/20 Amps socket outlet independent complete all as specified and as directed. 119 Piano type switch, 2 way, 6 Amps, flush type, complete all as specified and as directed 120 Piano type bell push, 1 way,6 Amps, flush type, complete all as specified and as directed. 121 Call Bell, ding dong type suitable for 230 / 240 volts AC 50 Hz all as specified and as directed. 122 Supply and fix in replacement ceiling fan of 1200 mm sweep, 230 V, 50 hz, min air delivery 210 CFM with service value with brussless direct current motor (BLDC) including all connecting accessories and step type regulator of 5 steps, connecting with suitable flexible electric wire complete all as directed by engineer-in-charge. 123 Ceiling rose, 3 terminal, surface bakelite 65 x 50mm complete all as specified and as directed. 124 Piano type switch, 1 way, 5/6 Amps, flush type, complete all as specified and as directed 125 Socket outlet 2 in 1, 5/6 Amps,flush type complete all as specified and as directed. 126 Switch socket combination 5 pin, 6 Amps,flush type complete all as specified and as directed. 127 Switch socket combination 2 in 1, 5 and 15/16 Amps,flush type complete all as specified and directed. 128 Earthing complete with galvanized Steel earth plate electrode 600 x 600 x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 meters below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and incl galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by GI protection pipe light grade 15mm dia connected to main earth wire on pole or controll board GI pipe light grade 20mm bore for watering funnel with wire mesh PCC chamber pit in PCC 1:3:6 type C-1 40mm yhick Precast RCC -25 cover reincorced with 8 mm dia TMT bars @ 10 cm C/C on both sides and handle, excavation and earth work in any type of soil and removal upto 50m complete all as sprecified and shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed. 129 Supply,laying ,jointing and testing in repair of Cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armoured,electric power cables(heavy duty) 1100 volts grade with stranded aluminium conducter of size 16 sqmm 4 core, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts including cable gland of suitable sizes and aluminium lugs for connection,complete all as specified and directed.Note:- Excavation,earthwork,sand cushioning, brick protection shall be measured & paid separately complete all as specified and directed. 130 Excavation in trenches n.exc 1.5 M wide and n.exc 1.50M indepth for taking up or laying of under ground cable in soft/loose soil and getting outcomplete all as specified and directed. 131 Removal excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all, as specified and directed by Engr-in-Charge. 132 Returning, filling in and including spreading, levelling,watering and well ramming in layers not exceeding 25 cm thick. complete all as specified and directed. 133 Sand cushioning to under ground cable providing with a layer of 8 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified and directed. 134 Sub class B, well burnt bricks locally avaiblable best quality, laid flat with width equal to length of brick for protection of under ground cable complete all as specified and directed at site. 135 Supply and fix in repair Submain wiring with two single core PVC insulated,unsheathed,stranded copper conductor cable (FRLS), 1100 volts gradeof size 6 Sqmm (nominal area) each and one single core 6 Sqmm (nominal area) as earth continuity conductor drawn into PVC conduit complete all as specified and directed.NOTE: (i)Rates for PVC casing capping with accessories are deemed to be included in the unit rate. (ii) Two run of 6 Sqmm and one run of 6 Sqmm copper cable shall be measured as one length. 136 Supply and fix in replacement connecting,testing and commissioning ofstreet light fitting 35 watt LED, IP-65 protection, single peice pressure die cast aluminiumhousing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and control gear compartmentwith high voltage surge protection device up to 5 KV, prewired including three core PVC insulated , sheathed 1.5 sqmm multistranded aluminium conductor with 2 core 1.5 sqmm pvc insulated cable from junction box to light fitting complete all as specified. 137 Street light bracket made out of GI tubing 40mm bore,light grade, 1.5 metre long bent to shape as directed, including suitable MS clamp of F.I. 50 x 6mm with MS bolts, nuts and washer fixed to steel tubular pole/PCC pole duly painted with two coats of aluminium paint complete all as specified and directed. 138 Supply and fix in replacement of old U/S DBs with wooden board / boxes and S&F distribution board, IP 43 in sheet metal enclosure dully flushed in wall, when MCB to be used with 200 Amps rated copper bus bar confirming to relevant IS SPN (04 Way double door) Make: Legrand or equivalent in ABB/Schneider and making good the disturbed surface all as directed by Engg-in-charge. 139 MCBSPN 40 Amps 240V, C series complete all as specified and directed. 140 MCB single pole 6 to 32 Amps, 10 KA, C seriescomplete all as specified and directed. 141 MCBSPN 63 Amps 240V, C series complete all as specified and directed. 142 Supply and fix in replacement TPN DB 4-ways, IP 43 - IK 09 with metal double door (MCCB as incomer) suitable for surface/flush mounting as per site requirement withcopper bus bar, withneutral bar, earth bar and cable ties for cable arrangement, fully insulated bus bar and neutral bar, door earthing, corner shield for better protection, pan assembly confirming to IS 8623 including making fixing arrangement with existing wall complete all as specified and as directed. 143 MCCB 63 Amps 4 pole 415 volts 25 kA Ics=75% Icu including extended terminals all as specified and directed 144 Supply and fixing Inverter LED batten 20W with square profile and polycarbonate channel, lithium Ion battery with charging time 8 Hours-10 Hours and backup time upto 4 Hours with driver, holder including LED tube light connecting up with three core flexible copper conductorcable of suitable size from ceiling rose complete all as specified and as directed. 145 Lamp holder insulated body complete all as specified and as directed. 146 LED Lamp, CDL, 9/10 watt, B22 base complete all as specified and as directed. 147 Supply and fix in repair for Decorative wall light fixture gold finish fixture with white glass diffuser suitable for 7.5 W LED filament lamp E27 Including bulb complete 148 Supply and fix exhaust fan made of study Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and as directed. 149 Galvanised iron tubes light grade of size 40 mm with all fitting and fixed complete on roof top complete all as specified and as directed.

Key Value

Document Fees
INR 500 /-
Tender Value
INR 38.80 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail