| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store and making good disturbed surfaces of walls, floors, etc compete all as specified and as directed |
| 2 | Taking down/ dismantling old Main Board with MCBs including meter box and energy meters of any size and capacity along with teakwood boards & energy meter keep in safe at MES store for refixing complete all as specified and directed by Engr-in-charge. |
| 3 | Taking down UNSV sub main wiring of any size make, type and capacity including making good disturbed surfaces complete all as specified and directed. |
| 4 | M&L point wiring with 1.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non metallic PVC FRLSH conduit (medium grade) Concealed in wall / ceiling with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) incl Sunken Iron Boxes / pressed steel modular terminal boxes any size/module, concealed on walls and fixed by means of brass screws incl modular cover plates and cover frame any size/module, for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories incl making good of wall surface by cementing / plastering, applying wall putty incl 02 coats of distempering in disturbed surface with existing colour complete all as specified and directed complete all as specified and directed at site for the following:- .(Make of wire: Finolex/Polycab/Plaza Make of PVC Conduit :-Plaza/Prestoplast/Precision) |
| 5 | One light point / Fan point ,Bell point controlled by one, one-way switch, complete all as specified and as directed |
| 6 | One switch socket outlet 3 pin 5 Amps, on Same board complete all as specified and as directed |
| 7 | One switch socket outlet 2/3 pin 5 Amps, on Independent board complete all as specified and as directed |
| 8 | All as per item No 4 above but with 2.5 sqmm PVC insulated FRLSH, multistranded copper conductor cable 1100 V grade and 2.5 Sqmm PVC insulated FRLSH multistranded copper conductor cable 1100 V grade for one 3 pin, 5/15 Amps switch socket outlet on independent board complete including taking down of old U/S point wiring all as specified and directed. |
| 9 | All as per item No 4 above but with 4.0 sqmm PVC insulated FRLS, multistranded copper conductor cable 1100 V grade and 4.0 Sqmm PVC insulated FRLSH multistranded copper conductor cable 1100 V grade for one 3 pin, 5/15 Amps switch socket outlet on independent board complete including taking down of old U/S point wiring all as specified and directed. |
| 10 | S&Fincluding connection of modular switch one way 6 Amps 1 Module complete all as specified and directed. |
| 11 | Supply & fixing including connection modular Switch socket combination 2 in 1,6 pin 16 amps 3 modules complete all as specified and directed. |
| 12 | Supply & fixing including connection modular Switch socket combination 2 in 1,5 pin 5 amps 3 modules complete all as specified and directed. (Make : .Crabtree/Cona/Havells) |
| 13 | S&FCeiling rose surface bakelite 65x50mm two to three terminal complete all as specified and directed. Make : SSK/Havells/Plaza. |
| 14 | S&Fmodular Bell push 6A 1 Module complete all as specified and directed. |
| 15 | S&F Call Bell, Ding-Dong ,single pole, AC, 230 Volts complete all as directed by Engineer-in-Charge. Make:- Anchor/Cona/Havells. |
| 16 | S&F of Modular Fan regulator,120 watts as directed and specified by Engineer-in-charge. |
| 17 | S&F of stepped type Fan regulator,120 watts as directed and specified by Engineer-in-charge. |
| 18 | S&F in repair of Modular switch 5 Amps complete all as specified and as directed. |
| 19 | S&F in repair of Modular socket 5 Amps complete all as specified and as directed. |
| 20 | S&F in repair of Modular switch 15 Amps complete all as specified and as directed. |
| 21 | S&F in repair of Modular socket 15 Amps complete all as specified and as directed. |
| 22 | S&F in repair of modular cover plate one/two modular complete all as specified and as directed. |
| 23 | S&F in repair of modular cover plate four/six modular complete all as specified and as directed. |
| 24 | S&F in repair of modular cover plate eight/twelve modular complete all as specified and as directed. |
| 25 | S&F in replacement, High-quality design LED Tube light fittings in extruded aluminium housing with high quality PC diffuser 1x20/22 watt with enhances safety and reliable ,robust housing structure with efficiency of 120 lm/W ,decorative end caps complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable including taking down old light fittings complete all as specified and directed. |
| 26 | S&F LED in replacement light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 27 | S&F in repairs of flexible PVC flexible copper cable 1.5 sqmm 3 core complete all as specified and as directed. |
| 28 | S&F in repairs of flexible PVC flexible copper cable 2.5 sqmm 3 core complete all as specified and as directed. |
| 29 | S&F in repairs of flexible PVC flexible pipe 20mm complete all as specified and as directed. |
| 30 | S&F in repairs of flexible PVC Casing caping 20mm complete all as specified and as directed. |
| 31 | S & F sheet metal enclosure double door, vertical type for DBs when MCCBs to be used as incomer upto 125 Amp, 4 ways IP 43,IK 09, 415 volts with 200amps rated bus bar fixed sunk/ flush to wall by cutting the brick/stone masonary etc & taking down of unsv DB and making good of disturbed surface to match with existing colour of wall complete all as specified and directed.Note:- The space left after inserting MCB should be properly filled with blanking plate |
| 32 | S&FIP-43, IK 09 protection distribution board, SPN 8 Way, 240 Volts, sheet steel, powder coated, double door system, fitted with two covers suitable for use on 240 V, 50 HZ, with 200 Amps rated bus bar, neutral link each bar and din rail complete all as specified and directed. |
| 33 | S&FIP-43, IK 09 protection distribution board, SPN 4 Way, 240 Volts, sheet steel, powder coated, double door system, fitted with two covers suitable for use on 240 V, 50 HZ, with 200 Amps rated bus bar, neutral link each bar and din rail complete all as specified and directed. |
| 34 | S&F in replacement, MCB TPN 40-63 Amp, 240V, 10KA, \"C\" curve complete with connection testing and commissioning all as specified and directed by Engr-in-charge. |
| 35 | S&F in replacement, MCB SPN 40-63 Amp, 240V, 10KA, \"C\" curve complete with connection testing and commissioning all as specified and directed by Engr-in-charge. |
| 36 | S&F in replacement, MCB SP 6-32 Amp, 10KA, \"C\" curve complete with connection testing and commissioning all as specified and directed by Engr-in-charge. |
| 37 | S&F in replacement of MCCBs 415V,16KA, 4 Pole rated capacity 63 Amps, Ics = 100% Icu, complete with connection testing and commissioning all as specified and directed by Engr-in-charge. |
| 38 | S&F in replacement of MCCBs 415V,16KA, 4 Pole rated capacity 100 Amps, Ics = 100% Icu, complete with connection testing and commissioning all as specified and directed by Engr-in-charge. |
| 39 | Material and Labour for fixing AC Three phase static energy meter of accuracy class 1.0 415 volt , 50 Hz with backelit LCD display of rating 10 to 60 Amps and with 1 push button (measures and display KWH, KVAh,V, I, P.F) with transparent hinge type box (The comnay should provide a meter replacement warranty of 5 years) incl taking down of old unsv meter complete all as specified |
| 40 | Supply & Fixing in replacement, exhaust fan 300 mm sweep, steel body, 240 V AC, single phase complete with lovers and shutters including fixing of suitable size of SS wire mesh, provision of flexible three core copper conductor cable of 23/0.0076 upto ceiling rose and grouting 04 Nos full threaded bolts and nuts etc all as specified and directed. |
| 41 | S&F in repairs louvers shutter made of MS sheet metal 1.2mm thick for round base and 0.8mm thick for flaps confirming of mounting edges frames made of MS Flat of size 25mmx3mm including heavy duty rust proof passivated bolts, of size 50mm long 8mm dia to be fixed on wall after drilling and duly painted by two coats of synthetic enamelled paint (spray painting) over a coat of primer for exhaust fans up to size 380 mm sweep complete all as specified and directed. |
| 42 | M&L for making opening/hole suitable for fixing exhaust fan 200/300mm sweep including wooden bedding for fixing of exhaust fan and plastering finishing and making good the existing surface complete all as directed. |
| 43 | S&F in repairs of nut and bolt set wedge type fully threaded Design expansion zinc plated anchor fasteners 26 (carbon steel) complete all as specified and as directed . |
| 44 | S&F Call Bell in replacement, Ding-Dong ,single pole, AC, 230 Volts complete all as directed by Engineer-in-Charge. Make:- Anchor/Cona/Havells. |
| 45 | S&F in repair of PVC Extension Board six module with 15 Amps switch / socket heavy duty complete all as specified and as directed |