| 1 | S &F of 35 mm 1st class hardwood (Seasoned Teak, Deodar, Shisham wood) Gauzed and skeleton shutters, divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers and prepared to receivegauze, etc, fitted with cut and mitred beads for securing glass, etc.; sizes of members ofShutters as specified in SSR Part -I, Section 8, clause 8.24 (a); supplied and fitted to chowkats. Design/pattern of gauzed and skeleton door should be approved by EIC. |
| 2 | S/F ofBrass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed size 250 mm |
| 3 | S/F 200 mm Brass barrel tower bolts, with cast or sheetbarrel and rolled or cast bolts and fixed. |
| 4 | S/F of 150 mm Extruded brass handles, fabricated type polished. |
| 5 | Taking down shutters of any description exc 2 sqm and deposited to store. |
| 6 | S&F Butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, type B-11 (size-100mm) |
| 7 | S&F of Stainless steel wire cloth (SS-304 grade) of 0.36 mm nominal dia of wire and average width of aperture 1.40 mm. |
| 8 | S & Faluminium body (extruded) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed |
| 9 | M/L for Preparation of new or un treated surfaces of any description, not otherwise described over 10cm girth of widthand one coat priming the surface by pink primer andthen supply & apply two coat of synthetic enamel paint. (Make:Apcolite-Asian Paints, Luxol Hi Gloss-Burger Paints, Nerolac-Nerolac Full Gloss. (Sample and shade will be decided by EIC only). |
| 10 | Dismantling of Brick work in wall built in cement mortar |
| 11 | M/L for brick work built in sub class \"B\" and built in cement mortar 1:4. |
| 12 | M/L for excavation of earth n. exc. 1.50 mtr wide and 1.50 mtr depth getting out in soft and loose soil. |
| 13 | Providing, type-B-0 (12.5 mm graded aggregate) 1:2:4 cement concrete in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, etc. as directed (including shuttering) |
| 14 | S&F for Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns etc. |
| 15 | S&F for Mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirallyfor hooping for columns etc. |
| 16 | M&L for Cutting chases in brick wall, pinning in. making good to facings where required and pointing in cement mortar 1:3, cutting not exc 10 cm girth. |
| 17 | M& L for Slabs supported on walls, beams and columns in floors, roofs, landings, type B0 (1:2:4), (12.5 mm graded agregate) |
| 18 | M&L for form work for soffit of suspended slabs such as roof slabs, floor slabs etc (flat & roughfinish surface of concrete) |
| 19 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. (soft & loose soil) |
| 20 | M&L for Hardcore of broken bricks gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface |
| 21 | M&L for Cement concrete in foundations,Type D2*(1:4:8 ) 40 mm graded agregate filling and mass concrete |
| 22 | M/L for 40 mm thick Damp proof course in cement concrete 1:2:4type B-0 to horizontal or vertical surfaces including necessary formwork |
| 23 | M/L for Applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cum. per sqm |
| 24 | Polythene film, 50 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sqm |
| 25 | M/L for 100 mm thick Cement concrete type B- 1, 1:2:4 (20mm graded aggregate) |
| 26 | Demolition of PCCn. exc. 15 cm in floor. |
| 27 | Dismentling of Brickwork or stone/boulder masonry, laid dry |
| 28 | Surface dressing n exc 15 cm deep (soft/loose soil) |
| 29 | M/L forScreed bed or bedding layer of cement mortar 25 mm thick of 1:4 for laying floor finished |
| 30 | M/L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete |
| 31 | M/L for Rendering 12 mm thick cement mortar plaster 1:4 on wall & surface to be finished fair & even. |
| 32 | M/L for Rendering 12 mm thick cement mortar plaster 1:4 on wall & surface to beneeru finished. |
| 33 | M&L for preparation of surface of new plastered wall and then apply 2 mm thick wall care putty on wall. |
| 34 | M & L forapplying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 5489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces. |
| 35 | M&L ForSpreading neat cement slurry @ 3.0Kg/Sqm and make 40.00 mm thick plain cement concrete infloor type B-0 (1:2:4) 12.5 mm graded aggregate, smooth finish with using extra cement. |
| 36 | S & F Framed work as in doors or gates of angle of grade Fe 410-W (Gde-E- 250) quality-A or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete. |
| 37 | S &F 1.25 mm Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required |
| 38 | S & F of Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework and portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc and similar work conforming to Fe.290.Gde-E-165 |
| 39 | Welded steel wire fabric mesh weight n. exe 4 kg per Sqm supplied and fixed complete to wood or steel members |
| 40 | M&L for Cement concrete type B1, 1:2:4 (20 mm graded aggregate) in foundations, filling and mass concrete |
| 41 | S & F 125 mm Butt hinges, heavy weight, cold rolled mildsteel, and fixed |
| 42 | M/L for Preparation of new or un treated steel surfaces of any description, not otherwise described over 10cm girth of widthand priming the surface by red oxide zink chrome primer andapply two coat of synthetic enamelpaint.(Make:Apcolite-Asian Paints, Superlac hi Gloss-Shalimar Paints, Goodlass Nerolac paints, Brolac, Luxol Hi Gloss-Burger Paints, Nerolac-Nerolac Full Gloss. (Sample and shade will be decided by EIC only). |
| 43 | M/L for Cutting holes in brick walls exc half brick but n.exc 1 brick in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required |
| 44 | M & L forPVC (SWR) Gullytrap 110/125 mm with grating including jointing with solvent cement |
| 45 | S & F 110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors |
| 46 | S&F for 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides |
| 47 | S & F 100 mm Butt hinges, medium weight, cold rolled mildsteel, and fixed |
| 48 | Pre cast 3seatercoloured RCCpark garden Bench length 06 ft each, M-25 grade, smooth finished, prefered colour decided by the EIC. |
| 49 | S & F 25 mm steel water Tubes, \"medium grade\" galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors |
| 50 | S & F 25 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed |
| 51 | Material and Labour for 120 ft deep4 inch borewell drilling with U-PVC casing & screen pipes of dia 110 mm up to 100 ft depth confirming to IS-12818 including cleaning of bore for cleaned water and supply and fixingof01 HP submersible pump (make : crompton, Kirloskar, CRI) with all accessories i.e.suitable control panel, insulated copper cables supporting wire/ropestandard length etc with 40 mm delivery HDPE pipe with 40x25mm GI reducer and 25 mm GI nipple complete as directed by EIC. |
| 52 | S &F Steel work in tubular trusses including special shapedwasher etc. complete using ERW or induction butt weldedtubes conforming to I. S.1161-1979 grade St.-240 |
| 53 | Taking down Chowkhats or frames exc 1.5 sqm but n exc 4 sq m each removing to store |