Tender For CREATION OF 3 x 63 KVA SUB STATION AT PANDUSHAN, RAI AND GAHIND WITH HT/LT NETWORK 2.CREATION OF 25 KVA AT KANJIULLAR WITH HT/LT NETWORK 3. CREATION OF 100 KVA AT RAKHAMA WITH HT /LT NETWORK- 1 Installation, Commissioning of 63 kVA Transformer along with loading, unloading charges from Divisional Store to Site 2 Installation, Commissioning of 100 kVA Transformer along with loading, unloading charges from Divisional Store to Site 3 SITC of 25 kVA,11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate including loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard 4 Supply,Installation testing & commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Typeincluding loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard 5 SITC LT Fuse of suitable capacity (Please refer Tender Drawing of Fuse set) including loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard 6 SITC of 11KV 3 Phase Horn Gap / DO fuse set including loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard 7 SITC of 11 KV LA SET 9 KVA ,10 KA,LA WITH Polymer ,Porcelain Housing Station Type including loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard 8 SITC of 185 mm² Single Phase Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS typeincluding loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard 9 SITC of 70 mm² Single Phase Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS typeincluding loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard 10 Providing and Fixing of Alumunium Thimbles of sizes 11 Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover as per REC Standard and approved drawings. 12 SITC of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm including loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard 13 SITC of 9 Mtr. Long Pole ( ST-410 SP33) with base plate and cap including loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard 14 supply and laying of Cement bottoming 1:2:4 mix as per Standards 0.48 cum /pole muffing 20 cm above ground level ,including plaster and curing of concrete for ( 9 Mtr ST Pole ) as per REC Standard and approved Drawing 15 SITC of 8 Mtr. Long Pole (ST-410 SP15) with base plate and cap including loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard 16 supply and laying of Cement bottoming 1:2:4 mix as per Standards 0.40 cum / pole , muffing 20 cm above ground level ,including plaster and curing of concrete for ( 8 Mtr ST Pole) as per approved drawing and REC. standard 17 Supply, Transportation, Laying, stringing and binding of conductor including joints with PG clamps of required size 30 mm² ACSR Conductor (Weasel) along with fitting complete as per approved drawing and REC. standard 18 SITC of 100 kVA ,11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound , and with LV Cable Box having detachable Aluminium Gland plate including loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard 19 SITC of 11 KV pin insulator Complete (Polymer/Porcelain) 5 KN With Pinsincluding loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard 20 Supplying and erection of GI channel (100x50x6 mm) ,(75x40x6 mm) , GI Angle( 50x50x6 mm), 50X50X6 mm angle support including clamps for Sub-Station Frame / GI Channel “V’ cross-arm (75 x 40x6mm) with GI Angle Pole Top Bracket (50x50x6 mm) including back clamps of 50X8 mm for fixing V-Cross arm and pole top bracket as per REC approved Drawings. 21 Providing and Fixing of Galvanized Nuts and Bolts 22 Supply and erection of Danger Plate with clamps (writing in English and Regional Language ) as per approved drawing and REC. standard 23 Supply and fixing of anti-climbing Device with Clamps as per approved drawing and REC. standard 24 Providing and Fixing of LT Shackle with Muki Clamps (50*6mm) complete as per REC Standard and approved drawings 25 Painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint) 26 Sign Board Mentioning Name of Village ,Name of Work/scheme, Year of Implementing ,Implementing Agency PDD KPDCL Div Shopian & Name of Contractor 27 Geo Tagged Photographs of high resolution (Pre and Post Photographs) Both hard and soft copy (for e-compendium) 4 Photographs Per site 28 Supply,Fixing of Spike Earthing Rod 20mm 2,5 Mtr long with GI strip (25x3)mm as per approved drawing and REC. standard 29 Installation, Commissioning of 63 kVA Transformer along with loading, unloading charges from Divisional Store to Site 30 Installation, Commissioning of 100 kVA Transformer along with loading, unloading charges from Divisional Store to Site 31 SITC of 25 kVA,11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate including loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard 32 Supply,Installation testing & commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Typeincluding loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard 33 SITC LT Fuse of suitable capacity (Please refer Tender Drawing of Fuse set) including loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard 34 SITC of 11KV 3 Phase Horn Gap / DO fuse set including loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard 35 SITC of 11 KV LA SET 9 KVA ,10 KA,LA WITH Polymer ,Porcelain Housing Station Type including loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard 36 SITC of 185 mm² Single Phase Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS typeincluding loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard 37 SITC of 70 mm² Single Phase Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS typeincluding loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard 38 Providing and Fixing of Alumunium Thimbles of sizes 39 Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover as per REC Standard and approved drawings. 40 SITC of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm including loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard 41 SITC of 9 Mtr. Long Pole ( ST-410 SP33) with base plate and cap including loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard 42 Providing of Cement bottoming 1:2:4 mix as per Standards 0.48 cum /pole muffing 20 cm above ground level ,including plaster and curing of concrete for ( 9 Mtr ST Pole ) as per REC Standard and approved Drawing 43 SITC of 8 Mtr. Long Pole (ST-410 SP15) with base plate and cap including loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard 44 Providing of Cement bottoming 1:2:4 mix as per Standards 0.40 cum / pole , muffing 20 cm above ground level ,including plaster and curing of concrete for ( 8 Mtr ST Pole) as per approved drawing and REC. standard 45 Supply, Transportation, Laying, stringing and binding of conductor including joints with PG clamps of required size 30 mm² ACSR Conductor (Weasel) along with fitting complete as per approved drawing and REC. standard 46 Supply, Transportation, Laying, stringing and binding of conductor including joints with PG clamps of required size 50 mm² ACSR Conductor along with fitting complete as per approved drawing and REC. standard 47 SITC of 11 KV pin insulator Complete (Polymer/Porcelain) 5 KN With Pinsincluding loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard 48 Supplying and erection of GI channel (100x50x6 mm) ,(75x40x6 mm) , GI Angle( 50x50x6 mm), 50X50X6 mm angle support including clamps for Sub-Station Frame / GI Channel “V’ cross-arm (75 x 40x6mm) with GI Angle Pole Top Bracket (50x50x6 mm) including back clamps of 50X8 mm for fixing V-Cross arm and pole top bracket as per REC approved Drawings. 49 Providing and Fixing of Galvanized Nuts and Bolts 50 Supply and erection of Danger Plate with clamps (writing in English and Regional Language ) as per approved drawing and REC. standard 51 Supply and fixing of anti-climbing Device with Clamps as per approved drawing and REC. standard 52 Providing and Fixing of LT Shackle with Muki Clamps (50*6mm) complete as per REC Standard and approved drawings 53 Painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint) 54 Sign Board Mentioning Name of Village ,Name of Work/scheme, Year of Implementing ,Implementing Agency PDD KPDCL Div Shopian & Name of Contractor 55 Geo Tagged Photographs of high resolution (Pre and Post Photographs) Both hard and soft copy (for e-compendium) 4 Photographs Per site 56 Supply,Fixing of Spike Earthing Rod 20mm 2,5 Mtr long with GI strip (25x3)mm as per approved drawing and REC. standard Technical Officer Please Enable Macros to View BoQ information