Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | SCHEDULE ‘A’ PART-I CIVIL WORK (SCHEDULE OF ITEMS).Construction of two single women barrack (G+I) for Mahila Soldier including antitermite treatement, plinth protections, DPC, fixing of tiles and granite, APP roof treatment, all finishes as per schedule of finishes and provn for other fittings/ fixtures, complete in all respect as per specification and drawing No DGAR/Engr/360 Sheet No 1/20 to 20/20 Note : (a) Irrespective whatever items areshown on drawings and BOQ the buildings shall be completed in all respects. (b) Before the starting the works,contractor will carry out the testing of soil bearing capacity to check the stability of foundation at his own cost by Auth Agency/NIT/IIT and report will be submitted to HQ DGAR. In addition based on SBC test if there is requirement change in design of bldgs the same to be carried out with intimation to this HQ. |
| 2 | SCHEDULE ‘A’ PART-II PLUMBING WORK (SCHEDULE OF ITEMS). Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid. |
| 3 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. |
| 4 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931.15 mm nominal bore. |
| 5 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 6 | Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.15 mm nominal bore with 45 cm length. |
| 7 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineerin- charge. |
| 8 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 9 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as Specified. a) 15 mm nominal dia. |
| 10 | Providing and fixing C.P. Hand showerwith 15 or 20 mm inlet :150 mm diameter. |
| 11 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms. |
| 12 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 13 | Providing and fixing toilet paper holder :C.P. Brass. |
| 14 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
| 15 | Providing and fixing 100% stainless steel grating of approved make and quality grade 304 on top of floor trap. The rate includes the cost of all ancillary works and material as required to complete the works.127 mm.dia. |
| 16 | Providing and fixing 100% stainless steel grating of approved make and quality grade 304 on top of floor trap. The rate includes the cost of all ancillary works and material as required to complete the works.101 mm.dia. |
| 17 | Providing and fixing uPVC class-B(IS:13592) trap of self cleaning design complete including cost of cutting and making good the cut-outs in walls and floors etc. complete (P or S trap).110 mm inlet and 110 mm out let. |
| 18 | Providing and fixing 100mm dia nominal bore uPVC pipe (Class-III)-IS:4985 inlet fitting approximately upto 300mm long above the trap with one or more 40 OD/ 50OD/63 OD/75OD holes for jointing waste pipes from waste appliances jointed and sealed with epoxy based sealant complete. |
| 19 | Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For soil & waste pipes). Nothing extra will be paid for supports.(Inside Toilets & Kitchen).110 mm outer dia. |
| 20 | Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For soil & waste pipes). Nothing extra will be paid for supports.(Inside Toilets & Kitchen).75 mm outer dia. |
| 21 | Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For soil & waste pipes). Nothing extra will be paid for supports.(Inside Toilets & Kitchen).110 mm outer dia. |
| 22 | Providing and fixing uPVC Pipes complete (IS: 4985 Class-III) with uPVC pipe fittings e.g. elbows, tees, reducers, unions, plugs, flanges etc. and clamps and jointing with solvent cement including chase cutting and making good the walls etc. wherever required for waste connection from W. B., Sink, floor drains etc.40 mm outer dia. |
| 23 | Providing and fixing uPVC Pipes complete (IS: 4985 Class-III) with uPVC pipe fittings e.g. elbows, tees, reducers, unions, plugs, flanges etc. and clamps and jointing with solvent cement including chase cutting and making good the walls etc. wherever required for waste connection from W. B., Sink, floor drains etc.63 mm outer dia. |
| 24 | Providing and fixing floor drain (FD) with 75mm outlet and 100 mm inlet with PTMT grating having 19mm seal for indirect floor drain (FD). |
| 25 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-in-Charge.Internal Exposed on walls:-PN - 16 Pipe, 20mm OD (SDR-7.4). |
| 26 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-in-Charge.Internal Exposed on walls:-PN - 16 Pipe, 25mm OD (SDR-7.4). |
| 27 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work,including cutting chases and making good the wall etc.:- PN - 16 Pipe, 20mm OD (SDR-7.4). |
| 28 | Providing, laying, testing & commissioning of \"B\" class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm. |
| 29 | Providing, laying, testing & commissioning of \"B\" class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :40 mm. |
| 30 | Providing, laying, testing & commissioning of \"B\" class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :50 mm. |
| 31 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm dia nominal bore. |
| 32 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm dia nominal bore. |
| 33 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore. |
| 34 | Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main :25 mm nominal bore. |
| 35 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Circular tank. |
| 36 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :150 x 100 mm size P type.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. |
| 37 | Providing and fixing toilet cabinet with mirror to keep toilet items approved by Engineer-in-charges. |
| 38 | SCHEDULE ‘A’ PART-III ELECTRICAL WORK (SCHEDULE OF ITEMS).Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B. |
| 39 | Wiring for One light point controlled by 10A SP MCB with 2x1.5 and earthing with 1.5 sq mm PVC insulated copper coductor earth wire in surface/recessed medium class PVC conduit etc. as required.(without cost of sp mcb). |
| 40 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. |
| 41 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. |
| 42 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire. |
| 43 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.4 X 6 sq. mm + 2 X 6 sq. mm earth wire. |
| 44 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.4 X 10 sq. mm + 2 X 6 sq. mm earth wire. |
| 45 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.4 X 16 sq. mm + 2 X 6 sq. mm earth wire. |
| 46 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 47 | Supplying and drawing UTP 4 pair CAT 6 LAN in the existing surface/ recessed steel/ PVC conduit as required. |
| 48 | Supplying and drawing UTP 4 pair CAT 6 LAN in the existing surface/ recessed steel/ PVC conduit as required.One Run of cable. |
| 49 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 50 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 51 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.(For telephone, tv socket and bell push). 1 or 2 Module. |
| 52 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A Modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 53 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 54 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed PVC conduit, and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B. |
| 55 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including prociding and fixing 25 A socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 56 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator).6 Way (4+18), Double Door |
| 57 | Supplying and fixing following way, horizontal type single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). 6 WayDouble Door |
| 58 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 59 | Supplying and fixing following rating, four pole, 415V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40A. |
| 60 | Supplying and fixing following Sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20mm. |
| 61 | Supplying and fixing following Sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25mm. |
| 62 | Supplying and fixing following Sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.32mm. |
| 63 | Supply and fixing 8W Led tube rod comprising of LED tube with non-integral/integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with system efficacy> 100 lm/Watt. LED driver PF> 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. |
| 64 | Supply and fixing surface mounting LED down lighter, LED of 12w assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD < 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium/CRCA powder coated frame with glare free diffused polycarbonate cover. |
| 65 | Supply and fixing of LED Luminaires BATTEN20W LED Tube Light of Box Type Prewired Indoor Luminairewith Energy Efficient Electronic Ballast, with End Caps Complete as Required.(Technical Data - System power 20W, CRI ≥80, Power Factor ≥0.95, System Luminous Efficacy ≥100). |
| 66 | Supply and fixing surface mounting LED down lighter, LED of 9w assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD < 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium/CRCA powder coated frame with glare free diffused polycarbonate cover. |
| 67 | Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 68 | Supply and installation of heavy duty type exhaust fans of following size sweep with gravity louvers shutters including all accessories/installation materials required make GEC, Crompton./havels :- 305 mm sweep 1400 rpm. |
| 69 | Supply installation testing and commissioning of The stylish unloaded Synergy Wallplates were designed specifically to accept the UTP Datagate Connector. The unloaded Synergy Wallplates are available in 1, 2 and 4 port variants, in five colours, to co-ordinate with any decor and any installation size.should be accomodates UTP, STP I/O.SINGLE FACE PLATE WITH GANG BOX. |
| 70 | Providing and fixing desert cooler as per requirement of users (India made). |
| 71 | SCHEDULE ‘A’ PART-IV LIGHTENING CONDUCTOR (SCHEDULE OF ITEMS). Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 72 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc.complete as required. |
| 73 | M& L for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3Nos 8mm dia 25mm long hex, head screw. |
| 74 | M&L for Aluminium Strip 25x3.15mm with saddles and fixing screws etc, for roof conductors and down conductors above ground. |
| 75 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 76 | SCHEDULE ‘A’ PART-V SITE LEVELING (SCHEDULE OF ITEMS). Site leveling/Earh work excavation over areas not exceeding 30 cm depth and filling of earth whereever required including ramming, watering and compacting in level. All kinds of soil. |
| 77 | SCHEDULE ‘A’ PART-VI BOUNDARY WALL (SCHEDULE OF ITEMS). Earth work in excavation by mechanical means (Hydraulic exacavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the exavated soil and dipsosal of surplus exacated soil as directed, within a lead of 50m. All kinds of soil. |
| 78 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 Coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm mominal size derived from natural sources) |
| 79 | Providing and laying in position speciafied grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 Cement :1.5 coarse sand (Zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 80 | Filling available exacvated earth (excluding rock) in trenches, plinth, sides of foundations etc, in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5m. |
| 81 | Reinforced cement concrete work ini Columns above plinth level up to floor five level, excludingcost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 Cement : 1.5 coarse sand (sone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 82 | Reinforced cement concrete work in beams, lintels, bands above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 Cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources. |
| 83 | FORM WORK : Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. |
| 84 | FORM WORK : Centering and shuttering including strutting, propping etc. and removal of form for lintels, beams, plinth beams, girders. |
| 85 | FORM WORK : Centering and shuttering including strutting, propping etc. and removal of form for columns. |
| 86 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanacally Treated bars of grade Fe-500D or more. |
| 87 | Half brick masonry with commong burnt clay F.P.S (non modular) bricks of class designationo 7.5 in superstructure above plinth level up to floor V level. Cement mortal 1:4 (1 Cement : 4 Coarse sand) |
| 88 | 15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement : 4 fine sand) wall both sides. |
| 89 | Finishing wall with water proffing cement pkaint of required shade :13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 90 | Wupplying at site Angl iron post of required size including bottomto be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia etc. complete |
| 91 | Fencing with angle iron post placed at required distance embedded in R.C.C post and procided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two post fitted and fixed with G/I staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payhment to be made per metre costg of total length of barbed wire used. with G/I barbed wire. |
| 92 | SCHEDULE ‘A’ PART-VII EXTERNAL WATER SUPPLY WORK (SCHEDULE OF ITEMS).Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work 32 mm dia nominal bore. |
| 93 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work 40 mm dia nominal bore. |
| 94 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work 50 mm dia nominal bore. |
| 95 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work 62.50 mm dia nominal bore. |
| 96 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work 75 mm dia nominal bore. |
| 97 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : 80 mm nominal bore Horizontal. |
| 98 | Construction of Masonary Chamber60x60x75 inside in Brickwork Cement Mortar 1.6 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. |
| 99 | Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 80 mm dia. |
| 100 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore. |
| 101 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore. |
| 102 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore. |
| 103 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 65 mm nominal bore. |
| 104 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 80 mm nominal bore. |
| 105 | Providing and laying in position cement concreteof specified grade excluding the cost of centering and shuttering (for thrust blocks at bends and junctions of water lines )by 1:2:4 (1 cement : 2 coarse sand : 4 graded stone agg. 20 mm nominal size). |
| 106 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality LD- 2.5 Rectangular shape 600*450 mm internal dimensions. |
| 107 | SCHEDULE ‘A’ PART-VIII FOOTPATH WITH PAVER BLOCK (SCHEDULE OF ITEMS).Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil. |
| 108 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 109 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work upto plinth level.1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size). |
| 110 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete . |
| 111 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 112 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 113 | SCHEDULE ‘A’ PART-IX SEPTIC TANK (SCHEDULE OF ITEMS).Construction of 50 users septic tank including brick works, RCC slab, plastering, manhole and connection to soak pit and gas pipe complete in all respect as per DRG No. DGAR/Engr/355 sheet No. 1/1. |
| 114 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. |
| 115 | SCHEDULE ‘A’ PART-X SEWERAGE LINE (SCHEDULE OF ITEMS). Excavating trenches of required width for pipes, cable, etcincluding excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.50m including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. All kinds of soil Pipes cables etc. exceeding 80 mm dia. But not exceeding 300mm dia. |
| 116 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe |
| 117 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size). |
| 118 | Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete. |
| 119 | Constructing brick masonry manholein cement mortar 1 : 4 (1 cement : 4 coarse sand) with RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4gradestone aggregate 20mm nominal size); foundation concrete 1:4:8 mix(1 cement : 4 coarse sand : 8 gradedstoneaggregate40 mm nominalsize) insideplastering 12 mm thickwith cementmortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat cement and makingchannels incementconcrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd with a floating coat ofneatcement completeasper standard designInside size 90 x 80 cm & 45 cmdeep including CI cover with frame (light duty) 455 x 610mm internal dimensions, total weight of cover & frame to be not lessthan 38 kg (weight of cover 23 kg and weight of frame 15 kg) With common burnt clay F.P.S.(non modular) bricks of classic designation 7.5. |
| 120 | Extra for depth for manholes: size 90 X 80 cmWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5. |
| 121 | Providing and fixing square mouthS. W. Gully trapclass SP-1 complete with C.I. gratingbrickmasonry chamber with water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 180 x 150 mm. size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. |
| 122 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20 mm diameter round bar. |
| 123 | SCHEDULE ‘A’ PART-XI STORM WATER DRAIN (SCHEDULE OF ITEMS).Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 124 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (40% of Item No. 1). |
| 125 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 126 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - 1:5:10 (1 Cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size). |
| 127 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand). |
| 128 | 12 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand). |
| 129 | SCHEDULE ‘A’ PART-XII EXTERNAL ELECTRICAL WORK (SCHEDULE OF ITEMS).Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 130 | Providing and fixing 25 mm x 5 mm copper strips in 40 mm dia G.I.pipe from earth electrode, including connection with brass nut bolts , spring washer, excavation and refilling etc, as required ( copper plate earthing). |
| 131 | Providing and fixing 25 mm x 5 mm GI strip in 40 mm dia G.I.pipe from earth electrode, including connection with brass nut bolts , spring washer, excavation and refilling etc, as required ( copper GI plate earthing). |
| 132 | Providing& layingearth connection from earth electrode with 6 SWG dia GI WIRE from earth electrode including connection with GI thimbleexcavation and refilling etc as required. ( for GI pipe earthing ofpoles). |
| 133 | Supply & Laying of 25 x 5 mm copper earth strip in surface /recess. |
| 134 | Providing and fixing 25mm x 5 mm G.I. strips on surface or in recess for connections etc. as required. |
| 135 | Providing andfixing MVdanger noticeplate of200 mm x 150 mm madeofmild steelatleast 2 mm thickandvitreousenameled white on both sides & with inscription in signalred colour on front side as required.( on 7mts poles & panels) |
| 136 | Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 137 | Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 138 | Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 139 | Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.160 mm dia (OD-160 mm & ID-135 mm nominal) |
| 140 | Supplying and making end termination with brass comperession gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required 4 Core 25 Sqmm |
| 141 | Supplying and making end termination with brass comperession gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required 4 Core 16 Sqmm |
| 142 | Supplying and making end termination with brass comperession gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required 3.5 Core 240 Sqmm |
| 143 | Supplying and making end termination with brass comperession gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required 3.5 Core 95 Sqmm |
| 144 | Supplying and making end termination with brass comperession gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required 2 Core 50 Sqmm |
| 145 | Supplying and making end termination with brass comperession gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required 2 Core 16 Sqmm |
| 146 | Supplying and making end termination with brass comperession gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required 2 Core 10 Sqmm |
| 147 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. |
| 148 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. Pipe. |
| 149 | FLOOR PANEL ( LOCATED AT GROUND FLOOR ):-Incoming, 1 No. 125A FP on load change over switch with 1 no. 125A TPN MCCB(25KA) with extendeble rotary handle each with thermal over current, instantaneous, short circuit release, earth fault. Metering for incoming:- Digital Multifunction meter with RS-485 communication port for measurement ofPF, V, A & Hz , equivalent to EM6459,with CT as required. Phase indicating lamps RYBwith 2 Amps SP MCB back up. ON / OFF indicating lamps, Bus Bars:-Electrolytic high conductivity Aluminium three phase and neutral busbars rated at 80 Amps, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. Current density of Bus Bar to be 1.3 sq.mm / amp. Outgoings :-3 Nos. 63 amp TPN MCB of 10 KA breaking capacity,2 No. 40 amp TPN MCB of 10 KA breaking capacity,SPARE- 2 No. 40 amp TPN MCB of 10 KA breaking capacity. FLOOR PANEL as described above. |
| 150 | Supply installation, testing and commissioning of external post top lantern with following and complete as required. 6m high (5.0m above ground) SP 4 STEEL pole as approved, adopting socket at top for fixture mentioned below, base plate 300x300x6mm and provision for mounting junction box etc.- 1 set. |
| 151 | Erection of Pole in cement concrete 400x400x1000mm deep 1:3:6 ratio cement concrete foundation including excavation , refilling, secured with holding clamps, bolts, nuts, alighnment of poles casting etc. including 100 mm thick lean concrete shall be provided at the bottom. |
| 152 | LED type 50 Watt (Street Light) light fittings of all types with all accessories. |
| 153 | Suitable size Control box with 1 no. incoming and 2 nos. outgoing terminals and 2 nos. tap-out terminal with 1 no.5A HRC fuses complet 1 set. |
| 154 | Suitable number (S) 40mm dia Class-B GI Pipes(s) from above control box to upto 0.5 meter below ground level for power cable entry. |
| 155 | Supply of following size of 1.1 KV grade multicore aluminium cunductor PVC sheathed armoured cable as per IS 1554. 3.5 Core 300 Sqmm. |
| 156 | Supply of following size of 1.1 KV grade multicore aluminium cunductor PVC sheathed armoured cable as per IS 1554 4 Core 25 Sqmm. |
| 157 | Supply of following size of 1.1 KV grade multicore aluminium cunductor PVC sheathed armoured cable as per IS 1554 4 Core 16 Sqmm. |
| 158 | Supply of following size of 1.1 KV grade multicore aluminium cunductor PVC sheathed armoured cable as per IS 1554 3.5 Core 240 Sqmm. |
| 159 | Supply of following size of 1.1 KV grade multicore aluminium cunductor PVC sheathed armoured cable as per IS 1554 3.5 Core 95 Sqmm. |
| 160 | Supply of following size of 1.1 KV grade multicore aluminium cunductor PVC sheathed armoured cable as per IS 1554 2 Core 120 Sqmm. |
| 161 | Supply of following size of 1.1 KV grade multicore aluminium cunductor PVC sheathed armoured cable as per IS 1554 2 Core 50 Sqmm. |
| 162 | Supply of following size of 1.1 KV grade multicore aluminium cunductor PVC sheathed armoured cable as per IS 1554 2 Core 16 Sqmm. |
| 163 | Supply of following size of 1.1 KV grade multicore aluminium cunductor PVC sheathed armoured cable as per IS 1554 2 Core 10 Sqmm. |