| 1 | Demolition of brick work or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed. |
| 2 | M&L for brick work with sub class \"B\" bricks (using old size bricks) straight or curved on plan exc 6m mean radius built in CM 1:6, complete all as specified and directed. |
| 3 | Taking down cement plaster of any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified & directed. |
| 4 | M&L for 15mm thick rendering on brick or concrete wall surfaces in cement mortar 1:6, finished the surface even and fair without using extra cemnent, complete all as specified. |
| 5 | M&L for 15mm thick rendering on brick or concrete wall surfaces in cement mortar 1:4,finished the surface even and fair without using extra cemnent, complete all as specified. |
| 6 | M&L for 5mm thick rendering on concrete ceiling surfaces in cement mortar 1:3, finished the surface even and fair without using extra cemnent, complete all as specified. |
| 7 | M&L for applying 3mm in two layers of cement base wall care putty on plastered surface of wall and making the surface even & smooth for receiving distemper / paint of any description, complete all as specified & directed. |
| 8 | M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper, complete all as specified & directed. |
| 9 | All as per item No 08 here-in-before but on ceiling surfaces. |
| 10 | M&L for preparation of newly plastered surfaces of walls and applying two coats of exterior grade weather proof paint over a coat of weather resistant acrylic primer, complete all as specified and directed. |
| 11 | M&L for complete removal of existing treatment on old plastered surfaces of walls and applying two coats of oil bound distemper, complete all as specified & directed. |
| 12 | All as per item No 11 here-in-before but on ceiling surfaces. |
| 13 | M&L for complete removal of existing treatment on old plastered surfaces of walls and applying two coats of exterior grade weather proof paint, complete all as specified and directed. |
| 14 | Taking down chowkats or frames including shutter (without taking off shutters from the frame) area n exc 1.50 Sqm each, complete all as specified & directed. |
| 15 | Taking down chowkats or frames including shutter (without taking off shutters from the frame) areaexc 1.50 Sqm but n.exc 4.00 sqm each, complete all as specified. |
| 16 | S&F pressed steel frames made out of mild steel 1.25mm thick sheet, with with size of frame 105mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., and applying a shop coat of red oxide primer including prividing PCC 1:3:6, type C-0 (using 12.5mm graded crushed stone aggregates) for filling back of chowkhats, complete all as specified & directed. |
| 17 | S&F 35mm thick flush shutters, solid core construction, with block board core and plywood face panels commercial type with both faces, complete all as specified and directed. |
| 18 | S&F 150 mm long, aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 19 | S&F 150mm size extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and directed. |
| 20 | S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet,cast or extruded sections and fixing boltsand sliding bolts of extruded sections or cast aluminium complete alloy all as specified and directed. |
| 21 | M&L for prepration of new wooden surface of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthatic enamel paint over a coat of pink primer, all as specified and as directed. |
| 22 | S&F factory made steel window box type using ERW hollow \"P\" section comprising double frame for and including gauged and glazed skeleton shutter jointed internally with flat iron 40x4mm complete including grill of 8mm square bars, fixed horizontally @ 10cm c/c, including hinges, handle, tower bolts, stops, lugs etc., complete all as specified & directed. |
| 23 | Supply only 4 mm thick sheet glass, ordinary quality and glazing with glazing clips/oil putty in squares not exceeding 0.5sqm in each pane, complete all as specified. |
| 24 | Supply only galvanised mild steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.18 mmfixed with tinned tack or galvanised wire staples or fixed with nails and wooden beads, complete all as specified and directed. |
| 25 | S&F in repairs steel rolling shutters with 1mm thickness of lath, with out ball bearing including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, gear operated type with bevel gear box and crank handle, complete all as specified and directed. |
| 26 | M&L for preparation of new steel surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel paint, complete all as specified and directed. |
| 27 | Demolition of stone slabs or tiles of any description or thickness in any position laid, bedded and pointed in any mortar, complete all as specified & directed. |
| 28 | M&L for 18-20 mm thick machine cut kota stone slab flooring laid over and including 20 mm thick screed bed or bedding layer in CM1:6, jointed with grey cement slurry mixed with pigment to match the shade of slab including grinding, rubbing and polishing, complete all as specified and directed. |
| 29 | M&L for 18-20mm thick machine cut kota stone slab flooring as in riser of steps, skirting, dado etc laid over and including 10mm thick backing coat in CM 1:4, jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing, all as specified and directed. |
| 30 | Taking up or down 15mm bore steel tubing and connections, complete all as specified & directed. |
| 31 | All as per item No 30 here-in-before but 25mm bore. |
| 32 | S&F 15 mm bore tubes, \"medium grade\", galvanised, with all fitting; (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc) and fixed to wall / ceiling with clips, wall hooks, wooden plugs or laid in floors, complete all as specified. |
| 33 | All as per item No 32 here-in-before but 25mm bore. |
| 34 | Taking down rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan necks etc, complete all as specified & directed. |
| 35 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or floors, complete all as specified & directed. |
| 36 | S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or floors, complete all as specified & directed. |
| 37 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls, complete all as specified & directed. |
| 38 | S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls, complete all as specified & directed. |
| 39 | M&L for PVC floor trap of 75mm dia of outlet, plain with grating including jointing with solvent cement, including embedding with PCC 1:2:4 type B-1, complete all as specified & directed. |
| 40 | S&F 110mm bore PVC (SWR) bends any radius, complete all as specified & directed. |
| 41 | S&F 75mm bore PVC (SWR) bends any radius, complete all as specified & directed. |
| 42 | S&F 75mm bore PVC (SWR) vent cowl, complete all as specified & directed. |
| 43 | S&F in repair white vitreous china wash hand basin (flat back) of size 550 x 400 mm fixed on and including new brackets complete including 32 mm size brass chromium plated waste coupling, PVC waste pipeetc, complete all as specified and directed. |
| 44 | S&F in repairs white vitreous china squatting pan ‘ORISSA’ pattern of size 580mm x 440 mm white with integral foot rests with ‘P’ or ‘S’ trap, front or back inlet including all connection and provision of lime concrete base complete all as specified and directed.. |
| 45 | S&F in repairs PVC low level flushing cistern, valve less, Syphonic action type, double push bottom, 10 litres capacity with inlet, ball valve float and handle with and including brackets & PVC bend pipe 32 mm dia of required length and makingconnection completeall as specified. |
| 46 | S&F in repairs bib taps, cast copper alloy, fancy type, with crutch or butterfly handle, chromium plated, screwed down, screwed for iron pipe or for brass ferrule of 15mm bore, complete all as specified & directed. |
| 47 | S&F in repairs stop valves, cast copper alloy, fancy type, chromium plated with long shank & cup (concealed type), with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of 15mm bore, complete all as specified & directed. |
| 48 | S&F in repairs PVC connections 15 mm size with PTMT nuts of length 600mm, all as specified & directed. |
| 49 | S&F in repairs 600 mm x 450 mm size beveled edge mirror 5 mm thick of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified & directed. |
| 50 | S&F in repair tubular towel rail stainless steel chromium plated 20 mm dia D type 60 cm long between flanges, including brackets and fixed to walls, all as specified and as directed. |
| 51 | S&F in repairs soap dish, brass CP any type, fixed to plugs with chromium plated brass screws, complete all as specified and directed. |
| 52 | S&F in repairs sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, complete all as specified & directed. |
| 53 | S&F waste coupling of PTMT (half or full threaded), minimum weight 60gms, suitable for discharge pipe of 40mm bore dia, complete all as specified & directed.all as specified. |
| 54 | Supply and fix in repair 1000 litres capacity double layer, rotational molded, polythene water storage tank (cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 20 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe, complete all as specified and directed. |
| 55 | Dismantling brick tiles or terracing tiles single layer on roofs, complete all as specified & directed. |
| 56 | Demolition of mud/ mud phuska in roofs any thickness, including plastering and leaping if any and cleaning the roof surfaces with wire brushes and removal of mud /mud phuska to a distance exc 250 M and n exc 500 M, complete all as specified & directed. |
| 57 | M&L for cement concrete1:2:4 type B1 (using 20 mm graded stone aggregate) as in roof padding including finished even & fair without using extra cement, complete all as specified and directed. |
| 58 | M&L for priming roof surfaces and applying water proofing treatment over roof including preparation & cleaning of roof surfacecomprising of the following complete all as specified & as directed:-(a) Applying oil bound bituminous primer at the rate of 0.4 Ltrs/Sqm as per IS 3384-1986 on prepared surfaces. Surface shall be kept free till the moment, the primer is impregnated and the solvent oil in primer is evaporated. (b)Laying 3 mm thick APP polymeric water proofing membrane of weight not less than 3.0 kg/Sqm, black finish reinforced with non woven polyester matt, with a thermo fusible finish, torching overlaps with a propane or a butane gas torch, with a overlap of 75 mm at sides and 100 mm at the ends and sealing including applying a coat of cold emulsion bituminous primer, completeall as per manufacturer\"s instruction. |
| 59 | M&L for 20 mm thick screed bed or bedding layer of mortar in cement mortar 1:6 for laying PCC tiles etc, complete all as specified & directed. |
| 60 | M&L for pre-cast PCC tiles machine pressed of size 25cm x 25cm x 20-22 mm thick and joints grouted flush in cement mortar 1:3 mixed with integral water proofing compound (for screed bed and grouting of joints) as per manufacturer instruction, complete all as specified & directed. |
| 61 | M&L for preparation of new APP surfaces and applying two coats of aluminium paint, all as specified and directed. |
| 62 | Dismantling asbestos cement (corrugated, semi-corrugated, etc) sheets in roof coverings, complete all as specified and directed. |
| 63 | S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in lroof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 64 | S&F pre-painted galvaume aluminium zink coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covelring/cladding to wall, fixed with self tapping screws as specified, complete all as specified and directed. |
| 65 | Dismantling mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 66 | S&F steel work in tubular trusses/ square pipes including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 FE 410 grade E-250, complete all as specified and directed. |
| 67 | M&L for plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment using Fe-410-W (Gde-E-250) quality B, complete all as specified and directed. |
| 68 | Demolition of cement concrete (unreinforced) in ground floor and in paving n exc 15 cm thickness (below or above ground level), complete all as specified & directed. |
| 69 | M&L for 75 mm thick cement concrete 1:4:8, type D-2,(using 40 mm graded stone aggregate) as in sub base for path, complete all as specified and as directed. |
| 70 | M&L for sand cushioning for laying interlocking paver blocks, all as spcified. |
| 71 | M&L for machine pressed precast concrete coloured interlocking paver block of approved shape and size of 80mm thickness, with minimum compressive strength of 40 N/Sqmm (M-40 grade), without correction factor for chamfering, made in rubber moulds scratch proof lacquer coating on top surface, with grey cement and pigment, complete all as specified and directed. |
| 72 | M&L for cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregates), as in foundation, complete all as specified and directed . |
| 73 | M&L for chipping of spalled and loose concrete and cleaning rust from reinforcement by sand blasting scrubing down concrete surfaces with wire brushes cleaning with water allow to dry and applying a layer of Zinc rich epoxy primer as an anti rust on all exposed reinforcement followed by a layer of binding coat of approved epoxy adhesive on complete exposed surfaces of concrete to be gunited and applying two layers of guniting over steel welded mesh 2mm dia of wire and aperture 75mm. Total thickness of guniting not exc 40mm (Avg thickness) in cement mortar 1:2 using OPC 53 grade cement mixed with polycreate mixture @ 2% by weight of cement or as per manufacturer\"s instruction and finally applying cement plaster over guniting surface of required thickness to give even, uniform and smooth finishes confirming to proper geometrics in cement mortar 1:3 to match the existing surfaces as in sides, soffits of the slabs, chajjas, fins, facias, parapets, linetls, columns and beams etc complete including necessary scafolding, shuttering, chasing to brick work or RCC members at any height upto 6 storied buildings including removal of all small trees/ shrubs etc , complete all as specified and directed. |
| 74 | Taking down carefully unserviceable of aluminium point wiring complete except for ceiling or where not feasible fan/plug/bell but including fittings such as switches, ceiling rose, pendants, regulator etc. and making good disturbed surface to match with the existing surface of roof/ wall/ floor by applying putty and applying colour/ white wash finish complete all as specified and directed. |
| 75 | M & L for point wiring of concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including rigid non-metallic PVC surface conduit of 20mm dia or higher, medium grade complete with all PVC conduit accessories, GI metal flush box of 1.60 mm thick suitable for modular / conventional switches / sockets / fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the followings :- Note - All accessories likes modular top cover plate/ hylum sheet cover plate, Metal flush box, screws etc as applicable will be included in quoted rates. One light/fan/bell/exhaust fan point controlled by one switch. |
| 76 | All as per srl item No.75 here-in-before but for One 3 Pin socket outlet 5 Amps on Independent board. |
| 77 | All as per srl item No.75 here-in-before but for One 3 Pin socket outlet 5 Amps on same board. |
| 78 | All as per srl item No.75 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point. |
| 79 | M and L for point wiring complete with 1.5 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked, in existingconduitincluding 1.5 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked as earth wire, connecting to common earth dolly with thimble, including modular MS sunken box, modular white cover plate with frame, blanking plate etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light / bell point/fan/exhaust point controlled by one, one way switch 06 Amps complete all as directed.Note - All accessories likes modular top cover plate/ hylum sheet cover plate, Metal flush box, screws, as applicable will be included in quoted rates. |
| 80 | All as per srl item No. 79 here in before but point wiring for one socket outet point 3 pin 5 amps on the independent board. |
| 81 | All as per srl item No. 79 here in before but point wiring for one socket outet point 3 pin 5 amps on the same board. |
| 82 | All as per srl item no. 79 here-in-before but with 2.5 sq mmFRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 3/5 pin 15 Amp power point on Independent board. |
| 83 | Material and labour for point wiring complete with 1.5 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked, in & includingPVCconduitincluding 1.5 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked as earth wire, connecting to common earth dolly with thimble, includingmodular PVC box, modular white cover plate with frame, blanking plate etc and making good to the disturbed surfaces to match the existing complete all as specified and directed One light/fan/bell/exhaust fan point controlled by one switch.Note - All accessories likes modular top cover plate/ hylum sheet cover plate, Metal flush box, screws,as applicable will be included in quoted rates. |
| 84 | All as per srl item no. 83 here-in-before but One 3 Pin socket outlet 5 Amps on Independent board. |
| 85 | All as per srl item no. 83 here-in-before but One 3 Pin socket outlet 5 Amps on same board. |
| 86 | All as per srl item no. 83 here-in-before butwith 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point. |
| 87 | S & F Modular Switch 1 way 16 A, 1 Module with Protectin IP-20 |
| 88 | S & F Modular Socket 6 / 16 A - 2/3 Pin combined 2 module with Protectin IP-20 |
| 89 | S & F Modular Switch 1 way 6 /10 A, 1 Module with Protectin IP-20 |
| 90 | S & F Modular Socket 6 / 10 A - 2 / 3 Pin combined 2 module with Protectin IP-20 |
| 91 | S & F Modular fan regulator step type, 100W 2 Module complete all as specified and directed. |
| 92 | S & F of Ceiling rose surface Polycarbonate type with three terminals 240 Volts complete all as specified and directed. |
| 93 | Supply and fix in replacement of MCB protected modular AC/Geyser box complete with and including 6 pin socket, 3 pin plug top, modular cover plate, mini MCB SP 20 Amp capacity and PVC gang box etc, complete all as specified and directed byby Engineer-in charge. |
| 94 | Supply of surface/wall mounted 20W LED batten. Luminaire made up of Extruded Aluminum Housing with PC diffuser. the luminiare should be with IP20 from dust. The LEDs used should have CRI ≥ 80 and CCT 6500K. Luminaire system efficacy of ≥ 110 lumen/watt. The electronic driver used shall have a power factor ≥0.95 . Fixture must have voltage range protection from 140-270V along with inbuilt surge protection of min 2.5KV. The luminaire shall pass Insulation Resistance test @ ≥ 2MΩ. The luminaire Working Temp. range should be from0⁰ to 50⁰C. |
| 95 | Supply and fixing LED flood light 70 watt 230 V,AC, PF>0.9 and voltage rated 220V to 240V outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp as specified and directed. |
| 96 | Supply and fixing post top LED20 watt with pressure die cast aluminium housing 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete as specified and directed. |
| 97 | Supply of surface/wall mounted 10W LED batten. Luminaire made up of Extruded Aluminum Housing with PC diffuser. the luminiare should be with IP40 from dust. The LEDs used should have CRI ≥ 80 and CCT 6500K. Luminaire system efficacy of ≥ 110 lumen/watt. The electronic driver used shall have a power factor ≥0.95 . Fixture must have voltage range protection from 140-270V along with inbuilt surge protection of min 2.5KV. The luminaire shall pass Insulation Resistance test @ ≥ 2MΩ. The luminaire Working Temp. range should be from0⁰ to 50⁰C. |
| 98 | S & F in replacement of LED light Bulkhead fitting 1x9W / 1X10W, luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 99 | Supply and fix Building security light with high efficienthigh power LED street light 35/36 watt with inbuilt daylight sensor which switches ON/OFF automatically in the absence/presence of sunlight with lens with pressure die cast aluminium housing and enclosed with toghened glass IP-66, and Color Rendering Index (CRI>70), IP20, correlated Color Temparature (CCT- 5700K to 6500K) , PF>0.9 and Voltage rated 220V to 240V etc including bracket suitable for fittings, clamps, fasteners and all other fixing accessories complete all as specified and directed by Engr-in Charge. |
| 100 | Taking down sub main wiring of 4 Sqmm or any type/any size. |
| 101 | M&LSub main wiring concealed with 4 sqmm (Nominal area) with two runs of single core cable PVC insulated FRLS multistranded unsheathed copper conductor cable including 1100 V grade, drawn through Conduit including4 sqmm (nominal area) single core PVC insulated multistrand unsheathed copper conductor as earth wire and duly connected to all common earth pointall as Specified and directed by Engr-in-Charge. |
| 102 | Supply and fixin replacement of Distribution Boarddouble Doormade out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, recessed on wall, SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc and making all necessary connections complete all as directed. |
| 103 | All as per srl item No. 102 here in before but SPN 04 Way. |
| 104 | M&L in replacement MCB 6 to 32 Amp, B Curve type, 10kA, single pole with over load and short circuit protection complete all as directed. |
| 105 | Supply and fixing in replacement MCB, SPN type of 40 to 63 amps capacity, 240V, 10 KA with all connections complete all as directed. |
| 106 | Taking down carefully ceiling / exhaust fan of any size, sealing cable end, dismantling blades & removing fan and blades to store and refixing the same connecting up including provision of cable from ceiling rose or connector to fan/exaust fanincluding necessary nut, screw , fastener, suitable downrod etc completeall as directed. |
| 107 | Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as directed |
| 108 | Supply and fix in replacement of exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm including connection with flexible twin core cable to ceilingrose and making hole in wall complete all as directed. |
| 109 | M & L Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25 mtr deep below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all by means of nuts and bolt check nuts and washers of galvanised iron sheet all as shown in electrical plate Nos 2 of SSR Part - I and connected to and including earthing test point complete including testing filling of adequate quantity of charcoal dust and common salt including refilling earth and removal of surplus soil up to 50 mtrs PCC 1:3:6 type CI chamber precast RCC cover 40 mm thick reinforced with 6 mm dia MS bar 3 Nos both way with handle made but at 6 mm dia MS bar water pipe with wire mesh and connecting testing etc complete all as specified and directed. |
| 110 | Supply and laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm 2 core complete all as specified and directed. |
| 111 | S&F GI tubing lightgrade 80mm dia with all fittings laid in trenches/fixed on wall/ceiling including dismantling of old pipe etc. |
| 112 | Excavation in trenches not exe 1.5m depth and not exe 1.5m wide in Soft/loose soil and getting out complete as specified and directed |
| 113 | M & L for road cutting /hard standing for laying of cable and re making good the same to match the existing surfacecomplete all as directed by Engr incharge. |
| 114 | Supply and spread river sand for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming. |
| 115 | Supplying laying, brick sub class \"B\" common burnt laid in trenches for cable protection complete all as specified and directed. |
| 116 | Returning, filling in including spreading, leveling, watering and well ramming in layers not exe.25cm at a level complete all as specified and directed. |
| 117 | Removal of surplus soil to a distance not exe 50m and depositing where directed at a level not exe1.5m above the starting point complete all as specified and directed. |
| 118 | Taking down and refixing paver block / Inter locking tiles of any size including cement mortar bedding(but not baking) as per exitingtiles complete all as specified and directed |