| Sl. No. | Item Description |
| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, laying of cable etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in hard and dense soil complete all as specified and directed. |
| 2 | Returningfillingin, includingspreading, Levelling, watering and well ramming in layers not exc. 25cm in soft soil complete all as specified and directed. |
| 3 | Removing excavated material (soil/rock) to a distance exc. 250 Mtr and not exc 500 Mtr depositing where directed at a level notexceeding1.5mabovethestartingpoint complete all as specified and directed. |
| 4 | M&LPCC(1:4:8)typeD-2(using40mmgraded stone aggregate) as in foundations, filling and mass concrete all as specified and directed. |
| 5 | M&L for brickwork with fly ash old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete as specified and directed. |
| 6 | M&L for rendering 15mm thick in CM 1:6 on brick/ concretes on fair surfaces and finished the surface even and smooth without using extra cement complete all as specified & as directed. |
| 7 | M&LRendering15mmthickonfairfacesofbrick work or concrete surface in cement plaster 1:4 finishing the surface even & smooth without using extra cement & with WPC (WPC will be measured & paid separately) complete all as specified &directed. |
| 8 | SupplyonlyWPC.(IntegralWaterProofing Compound) complete all as specified &directed. |
| 9 | M&L for preparation of newly plastered surfaces and finishing walls with Premium Acrylic Smooth exterior paint (any tint) with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) over new prepared surface complete all as specified and directed. |
| 10 | M&L for preparing newly plastered surfaces of walls and applying 2 coats of oil bound distemper emulsion including a coat of alkali resistant primer over 3 mm wall care putty complete all as specified and directed. |
| 11 | Providing and fixing factory made UPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners,Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories Area not exceeding 2.00 sqm each.(Note:The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured for payment purpose.) |
| 12 | Providing and fixing factory made UPVC white colour fixed window made of extruded profiles with wall thickness of 2.3mm ( + 0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm), sash. T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket 1.2 +– 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners-5mm thick glazing with selected quality glass.Area exceeding 1.00 Sqm but not exceeding 2.00 sqm each.(Note:The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose) |
| 13 | Supply and fixing factory made UPVC door frame made of UPVC . Extruded sections having an overall dimension (extruded section profile) 48x40 mm (tolerance + 1mm), with wall thickness 2.0mm (+ 0.2 mm), corners of the door frame Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded.The hinge side vertical of the frames reinforced by galvanized M.S tube of size 19x19mm and 1mm (+ 0.1 mm) wall thicknes and 3 Nos stainless steel hinges fixed to the frame complete all as specified and directed. |
| 14 | Providing and fixing factory made UPVC white colour casement (Openable) Door made of extruded profile with wall thickness of 2.3mm ( + -0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling ol holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 +0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners.Hardware:[casement door handle made of zinc alloyed (white powder coated). Corner striker. Secondary Strikers. Cylinder. Door transmission gear made of mild sleel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated) [and 5mm thick glazing with selected quality glass.(Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose). |
| 15 | S&F 5 mmthick sheet glass,ordinary quality, sheet glass is ground or obscured or frosted on one side, size of each pane exc 0.50 Sqmand fixed to door/window shutter and partition wall by means of glazing clips rubber strips etc. complete all as specified and directed . |
| 16 | S&F Galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks or galvanized wire staples complete all as specified and directed . |
| 17 | M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed . |
| 18 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed . |
| 19 | M&L for TMT bars 6 to 8 mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed . |
| 20 | M&L for Formwork to sides and soffits of floor or roof beams, beams haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc also splays between floors and beams, etc rough finished flat concrete surfaces, etc. complete all as specified and directed . |
| 21 | M&L for Reinforced cement concrete type B1, 1:2:4, using 20mm graded stone aggregate (Nominal Mix) as in Beams, cantilevers, bressummers,Lintel beams, roof beams ,floor beam etc and finished conctrete surface flat complete all as specified and directed . |
| 22 | M&L for cement concrete type C1 1:3:6 (using 20mm graded aggregate) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, fixing of holdfast, plinth courses , string courses, lacing courses parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, filled inside the frame, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specifiedand directed. |
| 23 | S&F steel work intubular steel trusses including special shape washers etc. including forcolumns complete using ERW or induction butt welded tubesconfirming to IS1161-1979 grade St.-240 complete all as specified and directed. |
| 24 | S & FPre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed |
| 25 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 26 | M& L for preparation of new steel surfaces of any description, over 10cm in width or girth,not otherwise described , applying two coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed. |
| 27 | M& L for preparation of new steel surfaces of any description, over 10cm in width or girth,not otherwise described , applying one coat of black bituminous paintcomplete all as specified and directed. |
| 28 | Supply and fixing GI snap grid frame work (Grid size 605cm x 605cm) for false ceilingconsisting of main runner \"T\" of size 24mm x 32mm and 0.3mm thick , Secondary runner \"T\" of size 24mmx25mm and 0.3mm thick,GI angle24mmx24mm and 0.4mm thick,Bottom exposed capping of width 24 mm of all T-sections shall be of 0.25mm thick PPGI, hot dipped galvanised steel with zink coating not less than 120gm / Sqm ,ceiling grid system duly suspended by 4mm dia GI wire hanging from existing purlins /roof slab with butterfly clipsincluding Gypsum ceiling tilesof size 595 x 595 x 7 mm laminated with 0.04 mm thick polyvinyl film on the face side and 10 micron metalized polyester film on the back side fixed on GI snap gridcomplete all as specified and directed. |
| 29 | M & L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including wateringcomplete all as specified and directed. |
| 30 | M & L for 100mm thick cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in sub base to floor complete all as specified and directed. |
| 31 | M & L for screed bed or bedding layer of mortar 15 mm thick for laying floor finishes etc in Cement Mortar 1:6 complete all as specified and directed. |
| 32 | M&L non skid ceramic tiles 7-8mm thick coloured (Square/rectangular) area of each tiles exceeding 0.18 sqm but n exc 0.36 sqmin floors set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed. |
| 33 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard and dense soil complete all as specified. |
| 34 | M&L hard core of broken stone of gauge n exc 63mm deposited spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface etc complete all as specified and directed. |
| 35 | M&L for75 mm thick plain cement concrete 1:4:8 Type D-2 (Using 40 mm graded stone aggregate) as in sub base and finishing surfaces of concrete topping even and rough to receive the topping layer completeall specified and directed. |
| 36 | M&L for PCC 1:2:4 type B-1(20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed as required etc complete all as directed. |
| 37 | M & L for Sand filling under floors or in foundations including watering and consolidation all as specified and directed. |
| 38 | M & L for 80mm thickness M-40 Grade precast concrete interlocking paver block and pointed withgrey cement and pigment and of approved size and shape and confirming to IS 15658-2006, complete all as specified and directed. |
| 39 | Excavation in trenches n exc 1.5m wide n exc 1.5m deep and getting out in soft /disintegrated rock complete all as specified and directed. |
| 40 | M&L for PCC type C2 1:3:6 (40mm graded aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 41 | M&L for fly ash bricks, with old size bricks straight or curved on plan exc 6m mean radius built in CM 1:4. complete all as specified and directed. |
| 42 | M&L for PCC type B0 1:2:4 (12.5 mm graded aggregate) as in lintels upto1.5m clear span,cills,steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering,slightly rounded or chamfered angles and throating, as specified and directed. |
| 43 | M&L for PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in surface channel and drains complete all as specified and directed. |
| 44 | M & L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms moulds mitered /stopped ends etc. complete all as specified and directed. |
| 45 | All as per Item No 44 above but for additional 25mm inner girth over or under 30 cm all as specified and directed. |
| 46 | M&L for rendering 10 mm thick in cement mortar (1:4) on brick surface and finishingplastered surface even and smooth without using extra cement, complete all as specified and directed. |
| 47 | Returning, filling in, including spreading , levelling, watering and well ramming in layers not exc 25 cm as in soft/disintegrated rock complete all as specified and directed. |
| 48 | Excavation over area n exc. 1.50 M depth and getting out soft/disintegrated rock complete all as specified and directed |
| 49 | Excavation over area n exc. 1.50 M depth and getting out hard rock complete all as specified and directed. |
| 50 | M&L forstonewalling of random rubble stone masonary, uncoursed, well bounded, bedded & solidely hearted built in cement mortar (1:6) using locally available best stone complete all as specified and directed. |
| 51 | M &L Providing PCC bond stone (for stone walling), type B1 1:2:4 (20 mm graded aggregate) set in CM 1:6 complete all as specified and directed. |
| 52 | Extra over stone walling for hammer dressing to face stones & dressing to face beds and joints as specified at RR walling uncoarsed or brought upto coarse, max depression on face from straight edge held against the dressed surface n.exc 20 mm |
| 53 | M&L for PCC type C1 1:3:6 (20 mm graded aggregate) as in coping including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 54 | M&L for raised pointing to RR, uncoarsed or brought upto course stone masonry in CM 1:4 complete all as specified and directed. |
| 55 | Removing surplus excavated materials (rocks) to a distance exc 1.50 km but n exc 5 km & depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and directed. |
| 56 | M&L for hand packing (any thickness) broken stone at back of wall and raising (or lowering) to the required levelcomplete all as specified and directed |
| 57 | M&L for High density polyethylenepipes (HDPE) 75 mm bore of pipe pressure rating 6Kg/Sqcm laid in retaining walls |
| 58 | M & L for point wiring with 1.5 Sqmm (nominal area) PVC insulated, unsheathed, multistrand, 1100 volts grade copper conductor FRLSH cable single core, drawn through with and including non metallic PVCconcealed conduit of size 20mm dia and its accessories including one run of 1.5 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing,including steelbox of required module for modular switches/socketsall as specified and directed.-Note:-surface Conduit shall be laid in celing portion only. |
| 59 | One light/fan/Bell/Buzzer point controlled by one switch. |
| 60 | One 3 pin 5 amps socket point on independent board |
| 61 | One 3 pin 5 amps socket point on same board |
| 62 | M & L for point wiring with 2.5 Sqmm (nominal area) PVC insulated, unsheathed, multistrand, 1100 volts grade copper conductor cable FRLSH single core,for 15 Amp 5/6 pin socket point on independent board, drawn through with and including non metallic PVC concealed conduit of size 20 mm dia and its accessories including one run of 2.5 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing, including steelbox of required module for modular switches/socketsall as specified and directed by engr-in-charge . |
| 63 | M&L ceiling rose, 3 phase/PVC/polycarbonate, isolated body Make:Plaza/Anchor oe equivalent |
| 64 | Supply and Fixing Modular switch 1 way 6A, 1 module. |
| 65 | Supply and Fixing Modular switch 1 way16A, 1 module |
| 66 | Supply and Fixing Modular Socket, 6A - 2/3 pin combined 2 module, |
| 67 | Supply and Fixing Modular Socket, 6A/16A - 2/3 pin combined 2 module, |
| 68 | Supply and Fixing Modular White cover plate with frame,3 module |
| 69 | All as per Item No 65 above but for 4 module |
| 70 | All as per Item No 65 above but for 6 module |
| 71 | M& L for Submain wiring with two runs of 6 sqmm with one run of 6 Sqmm earth wire of 1100V gradeFRLSH insulated multi-stranded copper conductor, single core cable conforming to IS 694 drawn through and including PVC concealed conduiteand connected to common earth dollycomplete all as specified and directed.Note :- Three runs of 6 sqmm and one run of PVC conceald conduit shall be measured as one length for the purpose of measurement. |
| 72 | S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. |
| 73 | Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. and connecting up with twin core twisted flexible copper conductor cable with suitable size taking down old fitting complete all as specified and asdirected. |
| 74 | S & F Factory made distribution board in sheet metal enclosure in double door with 200A ratedbus bar,SPN 8 way, 240V for fixing MCB\"s complete all as specified and as directed. |
| 75 | MCB SPN ‘B’ Curve 10KA, 40 amps complete all as specified and directed . |
| 76 | MCB SP ‘B’ Curve 10KA, 5 to 32 amps complete all as specified and directed . |
| 77 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. complete all as specified and asdirected. |
| 78 | M & L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as shown on electrical plate No3 of SSR part-I complete all as specified and directed. |
| 79 | Surface dressing n. exc 15 Cm deep in Hard/Dense soil. |
| 80 | Excavating over areas, n exc 1.5 m deep and getting out in hard and dense soil complete all as specified and directed. |
| 81 | M&L for reinforced cement concrete (nominal mix) 1:2:4, Type- B1, (using 20mm graded crushed stone aggregate) as inChajjas complete all as specified and directed. |
| 82 | M&L for reinforced cement concrete (nominal mix) 1:2:4, Type- B1, (using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 83 | M&L for Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and as directed. |
| 84 | M&L for 40mm thick cement concrete ,1 :2:4, type B0 with 12.5mm graded aggregatemixed with WPC as per manufacturers instruction as inDamp proof course to horizontal or vertical surfaces including necessary formwork as specified anddirected. |
| 85 | M&L forapplying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 Cum. per Sqm over DPC as directed and specified. |
| 86 | M&L for Polythene film, 50 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 Kg per Sqm for DPC as directed and specified. |
| 87 | M&L Rendering 15mm thick in cement plaster 1:6 on otherthanfairfaceofbrickworkand finishinf the surface even and smooth without using extra cement completeallas specified &directed. |
| 88 | M & L for preparation of newly plastered surfaces and applying three coats of white wash complete all specified and directed. |
| 89 | S& F for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walkways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165for portionsframedandhungas gates,includingpintlehinges, stops, hand-made sliding bolts, etc. complete all as specified and as directed. |
| 90 | S & F for mild steel, plain, black sheet 1.60 mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed. |
| 91 | S & F for hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; completeallasspecifiedand directed. |
| 92 | M&LforPreparationofnew steel surfaces n. exc. 10cmwidthorgirthwhen unconnected with other painting or when painted in a different tintandapplyingtwocoatsof syntheticenamelpaint overacoatofred-oxide primer complete all as specified and directed. |
| 93 | S & F GI Metal Ceiling Lay in perforated Regular edge global white color tiles of size 595 x 595 mm and 0.5 mm thick with 8 mm drop; made of Gl sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20 % perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns(minimum), including factory painted after bending and perforation, and backed with a black glass fibre acoustical fleece of size 595 x 595 mm in true horizontal, suspended on interlocking metal grid of hot dipped galvanised steel sections ( galvanised @ 120 gm/sqm, both sides inclusive) consisting of main \" T \" runner with suitably spaced joints to get required length & of size 24 X 38 mm made from 0.30 mm thick ( minimum) sheet, spaced @ 1200 mm centre to centre and cross \" T \" of size 24 x 25 mm made of 0.3 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" @ 600 mm centre to centre to form a grid of 1200 x 600 mm and secondary cross \" T\" of length 600 mm and size 24 X 25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200 X 600 mm pannel to form grids of 600 X 600mm and wall angle of size 24 X 24 X 0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting / making, opening for services like defuser, grills, light fittings, fixtures, smoke detectors etc. main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 X 37X 35 X 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fastners, 4 mm Gl adjustables rods with galavanised butterfly level clips of size 85 X 30 X 0.8 mm spaced @ 1200 mm centre to centre along main \"T\" bottom exposed width of 24 mm of all T- sections shall be prepainted with polyester paint, all complete for all height as per specifications drawings and as directed by Engr-in-incharge. |
| 94 | M & L for machine cut kota stone slab flooring 20-25mm thick over 20mm thick in CM 1:6 cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer-incharge. |
| 95 | M & L for kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar including 10 mm thick rendering in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 96 | M & L for 75 mm thick cement concrete type C- 1, 1:3:6 (20mm graded aggregate) finishing even and smooth without using extra cementas in plinth protection complete all as specified and directed by Engineer-incharge. |
| 97 | M&L point wiring with 1.5 Sqmm (nominal Area), 650 /1100 Volts grade, PVC insulated FRLS multi stranded unsheathed copper conductor cablerecessed, in and including ERW rigid stove enamelled steel heavy duty conduit not less than 20mm dia, ISI marked with all flame proof conduit fittings, accessories and junction boxes as per site requirement for one light point/buzzer point controlled by one switch complete all as specified and directed by Engineer-in-Charge. |
| 98 | M&L point wiring with 2.5 Sqmm (nominal Area), 1100 Volts grade, PVC insulated FRLS multi stranded unsheathed copper conductor cablerecessed, in and including ERW rigid stove enamelled steel heavy duty conduit not less than 20mm dia,, ISI marked with all flame proof conduit fittings, accessories and junction boxes as per site requirement for one socketpoint controlled by one switchwith 2.5 Sqmm PVC insulated FRLS multi-strandedcopper conductor as earth wire complete all as specified and directed by Engineer-in-Charge. |
| 99 | M&L for flame proof weather proof rotary switch, single pole, on & off, with cable termination box in LM 6 of 16 Amps rating 250 volt . |
| 100 | Supply and fixing Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A,250V, 2P+earthcompleteall as specified and directed. |
| 101 | Supply and fixing FPWP LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. |
| 102 | Supply and fixing FPWP LED Bulk head light fitting 1x40 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. |
| 103 | M&L for Submain wiring with two runs of 6 sqmm with one run of 6 Sqmm earth wire of 1100V grade FRLSPVC insulated multi-stranded copper conductor, single core cable conforming to IS 694 drawn through and in cluding ERW rigid stove enamelled steel heavy duty conduit not less than 20mm dia fixed on wall / ceiling with PVC saddles and cadmium plated steel screws and connected to common earth dollycomplete all as specified and directed.Note :- Three runs of 6 sqmm and one run of ERW conduit shall be measured as one length for the purpose of measurement. |
| 104 | M&L weather proof 4 way distribution board, duct and vermin proof IP-65, LM-6 body, appropriate size with epoxy powder coating, including of the following item :-(a) Incoming : MCB 32 Amps, DP, 10 KA, - 01 Nos, (b)Outgoing: (i) MCB,SP, 6/10 Amps, 10 KA - 02 Nos,(ii)Make of DB :Syaam or equivalent in Make Flexpro or Sudhir. |
| 105 | M&L FP weather Junction box entry size4 way junction box 100 mm Dia Make :shyam Cat part No: SSPL/JB/105 or equivalent |
| 106 | M&L for Wiring for circuit/sub main wiring of FRLS PVC insulated copper conductor 2 single core 4 Sqmm along with earth wire 2.5 Sqmm in and including Rigid metalic ERW Steel conduit. |
| 107 | M&L for earthing complete with copper plate electrode of size60cm x 60cm x 3.15 mm thick buried directly in ground vertically at a depth not less than 2.25 metredeep below normal ground level with top edge of the plate not lessthan1.5 metre below normal groundlevel surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and electrode connections by using copper strip 20 x 3 mm by means of bolts, nuts, check nuts and washers made of copper and protected by light grade 40 mm dia GI pipe connected to main switch board or main control board, and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1: 2: 4 type C2 including excavation and earth work, disposal of surplus soil to a distance not exc. 50 mtr all as specified and as shown on Plate No 5 of SSR Part I (1991),including taking down old unserviceable/rusted earthing all as specified and directed by Engr-in-Charge. |
| 108 | Removing excavated material (Soil) n.exc 50 m and depositing where directed at a level n. exc 1.5 Mtrs. above the starting point complete all as specified. |
| 109 | Supply and spreading clean dry sand in trenches for cushioning all as specified for cable protection complete all as directed. |
| 110 | M & L for laying of sub class \"B\" brick common burnt clay building bricks,designation 75 complete for cable for protection complete all as specified and directed by engineer in charge. |
| 111 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanizedsteel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core complete all as directed. |
| 112 | S&F galvanised steel tubes medium grade, with all fittings and fixed complete to walls,parapets and ceiling or laid in floors/ PCC Foundation pillar for protection ofLT cable complete all as specified and directed for the following bore of pipes :- |
| 113 | 50 mm bore |
| 114 | S&F (in replacement) following items in the existing out door/indoor LT panels/AMF panels and connetion with using aluminum lugs/ferruls incl disconnection & connection of cable and making necessary alteration in panel/door using welding wk and cutting as required for proper fixing & connection complete all as specified and directed as below :- |
| 115 | MCCB 4 pole 40 amps rating, 16 KA breaking capacity, with separator at both side |