| 1 | Surface excavationSoft/loose soil n.exc (not exceeding) 30cm deep and averaging 15 deep and getting out complete all as specified and directed. |
| 2 | Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation, laying of cables etc. or for manholes, cesspits, shafts etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed. |
| 3 | M & L for providing plain cement concrete, type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 4 | M & L for hard core of broken stones or boulders of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed. |
| 5 | M&L for providing 150mm thick Cement concrete type D-2, 1:4:8 (40mm graded aggregate)complete all as specified and directed. |
| 6 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed. |
| 7 | Removing surplus excavated material (Soil) to distance exc. 1.50 Kilometre but not exc. 5.00 Kilometre and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed. |
| 8 | M & L for providing 100 mm thick cement concrete 1:2:4 type B-1 (using 20 mm grade stone aggregate) as in floor finishing top surface even and smooth with using extra cement complete all as specified and directed. |
| 9 | M&L for forming construction joints 30 mm deep x 10mm wide filled with sealing compound Grade \"A\" complete all as specified and directed. |
| 10 | M&L for providing 75 mm thick cement concrete type C1, 1:3:6 (using 20 mm gradedstone aggregate ) in plinth protection,laid in bay n exc 3.00 sqm each finished even and smooth without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 6 mm wide joints throughout the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and directed. |
| 11 | M & L for Brick work with fly ashbricks straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed. |
| 12 | M&L for 15 mm thick rendering in CM (1:4) on brick or concrete surfaces finished fair and even including mixed with liquid WPC as per manufacturer instruction complete(Note :- WPC will be measured and paid separately). |
| 13 | M&L for rendering 15 mm thick in patch in cement mortar 1:6 on fair face ofbrick work or concrete surfaces with surface finish even and smooth complete all as specified and directed. |
| 14 | Supply only liquid water proofing compound complete all as specified and directed. |
| 15 | M & L for preparation of newly plastered previously untreated surfaces of walls and applying twocoat of cement base paint over a coat of primer complete all as specified and directed. |
| 16 | M&L for preparationofNew plastered Surfaces of wall and applying two coat ofoil bound distemperover one coat of primer complete all as specified and directed. |
| 17 | Excavating Soft/loose soil in post holes (or similar holes) each n exc 0.5Cum, getting out, returning, filling in and rammingearth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and directed. |
| 18 | M&L for providing cement concrete Type C2, 1:3:6 (40 mm graded aggregate) in foundations, filling and mass-concrete complete all as specified and directed. |
| 19 | M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and directed. |
| 20 | S & F of mild steel framed work such as grills, gratings etc. with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe-290 Grade E-165 complete all as specified and directed. |
| 21 | M&L for Plate (plain or chequered)channels, square cut or notched (ordinary and counter sunk) forming holes with rivetedbolted or welded attachment complete all as specified and directed. |
| 22 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self coaching screwcomplete all as specified and directed. |
| 23 | M&L for surfaces of any description, over 10cm in width or grith, not otherwise described, new or previously untreated surfaces,Red oxide,two coat of synthetic enamel paint complete all as specified and directed. |
| 24 | M&L for Point Wiring for one light point controlled by one way switch completewith 1.5 Sqmm FR-LSH, PVC insulated unsheathed copper conductor single core multi stranded cable 650/1100 volts grade drawnin and including concealed non-metallic rigid PVC conduit medium grade with all fittings (ISI Marked) not less than 20 mm external dia but shall be increased as per actual site reqmt in accordance with clause no 19.125 of SSR part Ifixed concealed / recessedin wall / ceiling etc including 1.5 Sqmm FR-LSH, PVC insulated unsheathed copper conductor single core multi stranded cable 650/1100 volts grade as earth continuity wire including MS sunken pressed steel terminal boxes of suitablesize, made of sheet 1.6mm thick with 3.0 mm thick bakelite sheet top cover for complete all as specified. |
| 25 | One light point controlled by one way switch. |
| 26 | One Fan point controlled by one way switch. |
| 27 | One 3 pin socket outlet, 5/6 amps, on independent board. |
| 28 | M&L for point wiring with 2.5 sqmm single core 1100V grade FRLSH PVC insulated unsheathed multistranded copper conductor with in and including PVC concealed conduit medium grade with all fittings including pressed MS sheet (1.0mm thick) sunken box with 3mm laminated bakellite sheet cover ISI marked suitable for an independent6 pin 15/16 amps socket outlet ,including 2.5 sqmm single core 1100v grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dollyincluding cutting chases in walls / floors for concealed conduiting and making good disturbed surface areato match with the adjoining surface all as specified and directed. |
| 29 | S&F Wall/surface mounted type LED light fitting batten type complete with LED 1x 20Watt (4 feet long), extruded aluminium body with heat sink provided for efficient heat dissipation and integrate electronic drive complete with all accessories internally pre-wired and including connecting up with 3 coretwisted flexible copper conductor cable complete all as specified and as directed. |
| 30 | S&F LED Flood light fitting 100W, IP 65 made up of pressure die cast housing with toughenedglass and individual high power LEDs with secondary optics, IP65 protection,roadway luminaire with high powerLED as light source , complete with all accessories internally pre-wiredetc complete all as specified and directed. |
| 31 | S&F Air Circulator fans 230 volts single phase oscillating type, 600mm sweep suitable for wall mounting complete, with regulator, 180W, 1440 RPM, heavy dutycomplete all as specified and as directed. |
| 32 | S&F switch piano flush type one way 5 Amps 240 volts complete all as specified and directed. |
| 33 | S&F switch piano flush type one way 16 Amps SP 240 volts complete all as specified and directed. |
| 34 | S&F socket outlet 2 in 1, 5 pin 5/6 amps flush type 240 volts complete all as specified and directed. |
| 35 | S&F socket outlet 2 in 1, 6 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed. |
| 36 | S&F ceiling rose 65 x 50mm three terminals complete all as specified and directed. |
| 37 | S&F sheet steel powder coated distribution board, TPN 4 ways, 415 volts, with 200 Amps rated copper bus bar, neutral link, earth bar, IP 43 protection and double door, suitable for mounting MCCB up to 160 Amps as incomer and MCBs 12 Nos out going complete including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed.[Cat No. 5077 46 of make Legrand/ .Cat No. 1SYP061606C001of Make: ABB or equivalent make] |
| 38 | S&F MCCB 63 Amps,415 volts, 4 pole, Thermal magnetic release for line protection etc complete all as specified and directed. |
| 39 | S&F flush mounting factory made SPN DB\"s Double door, IP-43 Protection, IK-09 with metal door, with neutral bar, Earth bar andcables ties for cable management fully insulated bus bar 8 way with 100 Amps rated bus bar complete all as specified and directed. |
| 40 | S&F MCB SPN (single pole and neutral), 240 volts,40 Amps breaking capacity 10 KA, ‘C’ Series. etc, complete all as specified and directed. Make: legrand/schneider/siemens |
| 41 | Supply and fixing MCB SP (single pole) 240 volts, 6 - 32 Amps, 50HZ, 10 KA, ‘C’ series complete all as specified and directed.Make: legrand/schneider/siemens |
| 42 | S & F of 1100 volts grade heavy duty two single core 4 Sqmm size (Nominal Area) PVC insulated (FRLS) copper multi-stranded conductor cable as in sub main wiring, drawn into & including PVC conduit medium grade not less than 25 mm dia including its all accessories & fittings, fixed concealed with and including chase cutting and making good the same as per existing specifications along with a continuous run of 4 Sqmm size (Nominal size) stranded copper conductor PVC insulated (FRLS) (green colour) cable as earth wire complete all as specified and directed. NOTE: - TWO SINGLE CORE CABLES ALONG WITH EARTH WIRE AND PVC CONDUIT SHALL BE MEASURED AS ONE UNIT LENGTH. |
| 43 | M & L for making horizontal hole by mechanical Boring under hard standing, pavements or roads for insertion of GI pipes 40 to 80 mm bore and making good the disturbed surface complete all as specified and as directed. |
| 44 | Supply and laying 40mm bore light grade ISI marked GI Tubing laid in trenches or inserting in horizontal boring for cable protection including fixing with MS Clamp and nut bolts complete all as specified & as directed. Make :- Tata / swastik/ Jindal/ prakash. |
| 45 | M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to earth lead wire of GI wire 4mm dia by means of nuts/bolts and washers, check nuts of galvanized iron or steel including 15mm dia GI pipe light grade upto 1.5 mtr below GL for protection pipe, excavation and earth work charcoal dust, common salt, PCC 1:3:6type C-1 chamber with cover and RCC1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm c/c both way with MS handle 12mm dia PGI funnel and wire mesh all as shown in electrical plate No 5 of SSR Part-I connected to ear thing test point all as specified or indicated including testing on completion all as specified and directed. |
| 46 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 core complete all as specified and as directed. |
| 47 | Removing excavated material (Soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed. |
| 48 | M&L for Dry sand cushioning for protection of under ground cables (8cm before laying the cable and 15cm after laying the cable in trenches) complete all as specified and directed. |
| 49 | M&L for Well burnt Sub class \"B\", modular bricks laid dry, flat, over the cable abutting each other, length of brick equal to width of brick, complete all as specified and directed. |
| 50 | M&L for Brick work with sub-class `B\" bricks, straight or curved on plan exc6.0 mtr mean radius built in cement mortar 1:4 complete all as specified and directed. |
| 51 | M & L for rendering 15 mm thick cement plaster on other than fair faces of brick work or stone masonry surfaces with cement mortar 1:4 finished even and fair without using extracement complete all as specified and directed. |
| 52 | M&L for providing, cement concrete 1:2:4, type B1 in lintel upto1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lasing courses, parapets and railing upto 60 cm in height, coping, kneelers, apex stones, bed plates, water troughs and like including weathering, slightly rounded or chamfered angles and throating as directed. |
| 53 | M&L for reinforcedpipes ,class NP2, laid and jointed complete with collars 450 mm bore complete all as specified and directed. |
| 54 | M& L for road/hard standing cutting in any depth and any width for laying of hume pipes and other connecting items including making good to disturbed surface complete all as specified and as directed. |
| 55 | Dismantling brick tiles of any thickness or description complete all as specified and directed. |
| 56 | Demolition of Mud in roof of any thickness including plastering & leeping complete all as specified and directed. |
| 57 | M&L forproviding PCC 1:3:6 type-C1, (using 20mm graded stone aggregate)padding over slab as levelling course complete all as specified and directed. |
| 58 | M&L forwater proofing treatment on approachable roof withfollowing Specifications : 1. average 10mm thick plaster in CM 1:3 mixed with polymer based water proofing compound when levelling coarse is still green.2. After the surface is fully dried, applying a coat of bituminous primer @ 1.50 liters/Sqm.3. After primer, the entire roof surface shall be painted with hot, blown bitumen grade 85/25 confirming to IS-702 @ 1.2 Kg/Sqm4. Over hot bitumen, polymeric water proofing membrane consisting of 90 to 100 micron and 3mm thick central core of HMHDPE film and standard weight 3 Kg/Sqm shall be laid with 100mm side lap/end lap on prepared surfaces as per manufacturer’s instruction and strict supervision of manufacturer’s technical rep. |
| 59 | M&L for 20mm thick PCC tiles machine pressed 250 X 250 X 20-25 mm, factory made as per IS-1237-1980 with grey cement and pigment laid over a bedding layer of 15mm screed in cement mortar 1:3. The cement mortar screedand tiles joints shall be filled with polymer based cement proof joint filler manufactured by approved specification/instructions and tiles joints shall be filled with polymer based cement proof joint filler manufactured by approved company, complete all as specified and directed. |
| 60 | M&L for applying a coat of bitumen grade 85/25 at 1.20 Kg/Sqm over APP membrane and finally applying a coat of aluminium paint at 0.20 kg/Sq.m all as per manufacturer\"s instructions complete all as specified and directed. |
| 61 | M&L cutting outcrack in V section in existing roof, chajjas or similar work up to 40 mm deep and cleaning the same with water jets to get rid of any loose material and wetting, grouting with cement & sand mortar 1:3 mixed with liquid WPC complete all as specified and directed. |
| 62 | M&L plain cement concrete type B-1 1:2:4 mix (using 20 mm graded stone agg) as in roof kerb and the like rounded or chamfered on edges complete all as specified and directed. |
| 63 | Demolition of brick work built in cement mortar or cement lime mortar including all quions, arches, pillers etc complete all as specified and directed. |
| 64 | Disconnecting existing water tankn.exc 500ltrs capacity , setting aside or lowering if required for repairs ,cleaning etc and hoisting ,reconnecting and refixing in position complete all as specified and directed |
| 65 | Dismantling water tank n exc 500 ltrs complete all as specified and directed. |
| 66 | Dismantling water tank n exc 1000 ltrs complete all as specified and directed. |
| 67 | S&F rotational moulded polyethylene water storage tanks three layers (Cylindrical vertical with closed top) of 500 ltrs capacity hoisted and fixed in position all as specified and directedin SSR Part I complete all as specified and directed. |
| 68 | S&F rotational moulded polyethylene water storage tanks three layers (Cylindrical vertical with closed top) of1000 ltrs capacity hoisted and fixed in position all as specified and directedin SSR Pt I complete all as specified and directed. |
| 69 | S&F in replacement for PVC ball Valve, 20 mm bore high pressure of PTMT epoxy coating aluminium rod , with polythene float and flynut complete, screwed for iron pipecomplete all as specified and directed (Min wt =210gm ) ( 2 valve to be replaced) |
| 70 | Taking up or down steel tubing and connections, including cleaning for refixing or removal to store 15 mm bore complete all as specified and directed. |
| 71 | Taking up or down steel tubing and connections, including cleaning for refixing or removal to store 20 mm bore complete all as specified and directed. |
| 72 | S&F 15 mm bore of galvanised steel tubing medium grade with all fittingscomplete to walls and ceilings or laid in floors complete all as specified and directed. |
| 73 | S&F 20 mm bore of galvanised steel tubing medium grade with all fittingscomplete to walls and ceilings or laid in floors complete all as specified and directed. |
| 74 | Refixing old GI tubing and connection in new or old location after taking down , cleaning etc complete 20 mm borecomplete all as specified and directed. |
| 75 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks etc, (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed. |
| 76 | S&F110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls with MS clamps complete all as specified and directed. |
| 77 | S&F PVC (SWR) bendsany radius of bore 110 mm complete all as specified and directed. |
| 78 | S&F in replacement of20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwedboth ends or iron pipe and fixed complete all as specified and directed. |
| 79 | Taking down cement plaster including racking out joints hacking for key and scrubbing down with water complete all as specified and directed. |