Tender For Day To Day Repair And Maintenance Govt. Qtrs. At Toph Sherkhania, Jammu (Ort And Trt) Ending March 2026. Cno-501 Np- 1 CPVC PIPES AND FITTINGSProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot and cold water supply, including allCPVC plain and brass threaded fittings. This includes jointing of pipesand fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer-in-charge. Internal work-exposed on wall, including fixing the pipewith clamps at 1.00 meter spacing. 20mm nominal outer dia pipes. 2 25mm nominal outer dia pipes. 3 Internal work Concealed fixing the pipe with clamps at1.00 meter spacing including cutting chases and making good thewall etc. 20mm nominal outer dia pipes. 4 25mm nominal outer dia pipes. 5 External work including trenching, refilling etc. 20mm nominal outer dia pipes. 6 25mm nominal outer dia pipes. 7 G.I. PIPES AND FITTINGSProviding and fixing G.I. pipes complete with G.I. fittings and clamps,including cutting and making good the walls etc.:Light. Internal work-Exposed on wall. 15 mm dia. nominal bore 8 25 mm dia. nominal bore 9 Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank ISI : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank 10 C.P. BRASS FITTINGSProviding and fixing 15 mm nominal bore C.P. brass bib cock ofapproved quality conforming to IS : 8931 11 Providing and fixing 15 mm nominal bore C.P. brass long body bib cockof approved quality conforming to IS standards and weighing not lessthan 690 gm 12 Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 13 Providing and fixing water closet squatting pan (Indian type W.C. pan)with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C.flushing cistern, including flush pipe (of approved make) with manuallycontrolled device (handle lever) conforming to IS: 7231, with all fittingsand fixtures complete, including cutting and making good the walls and floors wherever required.18.1.2 White vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. 14 Providing and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 liter low level whiteP.V.C. flushing cistern, including flush pipe with manually controlleddevice (handle lever), conforming to IS:7231, with all fittings andfixtures complete, including cutting and making good the walls andfloors wherever required: W.C. pan with ISI marked white solid plastic seat and lid. 15 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as perI.S. 13983 with C.I. brackets and stainless steel plug 40 mm, includingpainting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board: 610x510mm bowl depth 200mm 16 610x460mm bowl depth 200mm 17 470x420mm bowl depth 178mm 18 Providing and fixing P.V.C low level flushing cistern with maually controlled device (handle lever) conforming to IS : 7231, with all fittingsand fixtures complete:18.19.1 10 liter capacity -White 19 Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C waste fittings complete:Flexible pipe. 32 mm dia 20 40 mm dia 21 Demolishing cement concrete manually/by mechanical means includingdisposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix) 22 1:4:8 or leaner mix (i/c equivalent design mix) 23 Demolishing R.C.C. work manually/by mechanical means includingstacking of steel bars and disposal of unserviceable material within 50meters lead as per direction of Engineer-in-charge. 24 Dismantling doors, windows and clerestory windows (steel or wood)shutter including chowkhats, architrave, holdfasts etc. complete andstacking within 50 meters lead : Of area of 3 sqm. and below 25 Of area beyond 3 sqm. 26 Taking out doors, windows and clerestory window shutters (steel or wood)including stacking within 50 meters lead : Of area of 3 sqm. and below 27 Of area beyond 3 sqm. 28 Dismantling tile work in floors and roofs laid in cement mortar includingstacking material within 50 meters lead. For thickness of tiles 10 mm to 25 mm 29 For thickness of tiles above 25 mm and upto 40 mm. 30 Dismantling old plaster or skirting, raking out joints and cleaning thesurface for plaster including disposal of rubbish to the dumping groundwithin 50 meters lead. 31 Taking out existing wooden door shutter, repair by cutting, painting etc.and refixing of repaired door shutters to existing door frames, includingreplacement of hinges with screws, etc. as required, all complete as per thedirection of the Engineer-in-charge. 32 Cleaning of terrace/loft water storage tank (inside surface area) upto2000litre capacity at all heights with coconut brushes, duster etc., removal ofsilt, rubbish from the tank and cleaning the tank with fresh waterdisinfecting with bleaching powder @ 0.5gm per litre capacity of tankincluding marking the date of cleaning on the side of tank body with thehelp of stencil and paint and disposing of malba all complete as perdirection of Engineer-in-Charge. (The old date already written on tankshould be removed with paint remover or black paint and if date is notwritten with the stencil or old date is not removed deduction will be made@ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock isdamaged that is to be repaired by contractor at his own cost and nothingextra will be paid on this account) 33 Renewing glass panes, with wooden fillets wherever necessary :14.7.1 Float glass panes of thickness 4.0 mm (weight not less than10kg/sqm) 34 Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape raking outjoints and preparing and plastering the surface of the walls completeincluding disposal of rubbish to the dumping ground within 50 meters lead14.1.2 With cement mortar 1:4 (1 cement : 4 coarse sand) 35 Painting with synthetic enamel paint of approved brand and manufactureof required colour to give an even shade, one or more coats on old work. 36 Removing dry or oil bound distemper, water proofing cement paint andthe like by scrapping and sand papering and preparing the surface smoothincluding necessary repairs to scratches etc. complete. 37 Distempering with 1st quality acrylic distemper, having VOC (VolatileOrganic Compound) content less than 50 grams/ liter, of approved brandand manufacture, including applying additional coats wherever required,to achieve even shade and colour. One coat 38 Two coats 39 Providing and applying white cement based putty of specified thickness,of approved brand and manufacturer, over the plastered wall surface toprepare the surface even and smooth complete. 1 mm thick 40 2 mm thick 41 Distempering with 1st quality acrylic distemper (ready mixed)havingVOC content less than 50 gms/litre,two or morecoats on new work ofapproved manufacturer, of required shade and colour complete as permanufacturer’s specifications 42 Distempering with oil bound washable distemper of approved brand andmanufacture to give an even shade on New work (two or more coats) overand including priming coat with water thinnable cement primer 43 6MM CEMENT PLASTER6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) 44 15mm Cement plaster on the rough side of single or half brick wall ofmix:13.5.2 1 : 6 ( 1 cement : 6 coarse sand) 45 VITRIFIED FLOOR TILESProviding and laying vitrified floor tiles in different sizes (thickness tobe specified by the manufacturer) with water absorption less than 0.08%and conforming to IS:15622 of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand)including grouting the joints with white cement and matching pigmentsetc. complete Size of tile 600x600 mm 46 Providing and laying rectified Glazed Ceramic floor tiles of size300x300 mm or more (thickness to be specified by the manufacturer), of1st quality conforming to IS : 15622, of approved make, laid on 20 mmthick cement mortar 1:4 (1Cement : 4 Coarse sand), including groutingthe joints with white cement and matching pigments etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown 47 Providing and laying Ceramic glazed floor tiles 300x300 mm (thicknessto be specified by the manufacturers) of 1st quality conforming to IS:15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4( 1 cement : 4 coarse sand) including pointing the joints with whitecement and matching pigment etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown 48 CERAMIC GLAZED TILESProviding and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622(thickness to be specified by the manufacturer), of approved make, in all colours, shadesexcept burgundy, bottle green, black of any size as approved by Engineer- in-Charge, inskirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement :3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 49 Frames and trussesProviding wood work in frames of doors, windows, clerestory windows andother frames, wrought framed and fixed in position with hold fast lugs or withdash fasteners of required dia and length (hold fast lugs or withdash fastenersshall be paid for separately): Second class kail wood 50 Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows fixing with butt hinges of required size withnecessary screws, excluding panelling which will be paid for separately, allcomplete as per direction of Engineer-in-charge. (Note: -Butt hinges andnecessary screws shall be paid separately).Rate for thickness ofshutter in mm per sqm35 mm Second kail wood 51 Providing and fixing panelling or panelling and glazing in panelled or panelledand glazed shutters for doors, windows and clerestory windows (Area ofopening for panel inserts excluding portion inside grooves or rebates to bemeasured). Panelling for panelled or panelled and glazed shutters 25 mm to 40mm thick.9.8.10 Particle Board 12mm thick Plain particle board flat pressed, 3 layer or graded wood particle boardmedium density Grade I, IS : 3087 marked 52 Providing and fixing fly proof wire gauge to windows and clerestory windowsusing wire gauge with average width of aperture 1.4 mm in both directions allcomplete.9.9.1 With Galvanized M.S. Wire gauge with wire of dia 0.63 mm. With 2nd class teak wood beading 62x19 mm 53 With 12 mm mild steel U beading 54 Providing and fixing glazed shutters for doors, windows and clerestory windowsusing 4mm thick float glass panes including ISI marked M.S. pressed butthinges bright finished of required size with necessary screws.Rate for thickness ofshutters in mm per sqm35mm Second class Kail wood 55 Providing and fixing ISI marked M.S. pressed butt hinges bright finished withnecessary screws etc. complete : 125x65x2.12 mm 56 100x58x1.90 mm 57 Providing and fixing ISI marked oxidized M.S. sliding door bolts with nuts andscrews etc. complete : 300x16 mm 58 250x16 mm 59 Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barreltype) with necessary screws etc complete. 250x10 mm 60 200x10 mm 61 150x10 mm 62 100x10 mm 63 Providing and fixing ISI marked oxidized M.S. handles conforming to IS : 4992with necessary screws etc. complete : 125 mm 64 100 mm 65 75 mm 66 CAST-IN-SITUProviding and laying in position specified grade of reinforced cement concrete includingcuring but excluding the cost of centering, shuttering, finishing and reinforcement. Allworks upto plinth level5.1.2 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 67 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiralstair cases upto five level including curing but excluding the cost of centring, shuttering,finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 68 FORM WORKCentering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platforms. 69 Shelves (cast-in-situ) 70 Edges of slabs and breaks in floors and walls. Under 20 cm wide 71 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing inposition and binding all complete above plinth level 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. 72 CEMENT CONCRETE (CAST-IN-SITU)Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) 73 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 74 P/F wardrobe with iron sheet hollow frame 4x1.5 with 24 and 26 gauge shutter with 22 gauge sheet in frame shutters including all hardware fittings lock and handle( godrej) make painting inside with plain finish with enamel paint outer side plain texture hammer paint( Asian, nerolac) fixing of frame with 3 fasteners with drilling and other job complete 75 P/F of wooden frame with iron gauge mesh for ventilation in kitchen and bathroom including cost of material and labour 76 carpenter 77 Helper 78 Plumber 79 Site clearance after completion of work by engaging labour 80 trolley for shifting mulba 81 Repair to steel gates, fixing of broken hinges by engaging welder including welding set with Helper 82 Providing and fixing of PVC tank lids (cover) to cover the top of water tank 83 Providing and fixing of PVC tank threaded cover including locking arrangement complete job 84 Brass Ball valve 1/2 85 Brass Ball Valve 3/4 86 Providing and fixing 600x120x5mm glass shelf with edges round off supported on anodized aluminum angle frame with C.P. brass bracketsand guard rail complete fixed with 40 mm long screws, rawl plugs, etc. complete 87 Towel ring 88 Soap Dish holder 89 Providing and fixing on wall face un-plasticized Rigid PVC rain waterpipes conforming to IS: 13592 Type A including jointing with seal ringconforming to IS: 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes 110 mm diametre 90 75 mm diametre 91 Nipple 12x1/2 92 6x1/2 93 4x1/2 94 2x1/2 95 1.5x2 96 1.5x4 97 1x4 98 1x2 99 Socket half inch 100 Elbow half inch 101 Tee half inch 102 Providing and fixing of Cp grating 100mm(LMR) 103 Providing and fixing of phase for repair of CP bib cocks( plain) 104 Providing and fixing of phase for repair of CP bib cock ( disk) 105 Providing and fixing of jet spray 106 Providing and fixing of english seat cover 107 providing and fixing of sink coupling 108 Providing and fixing G.I. pipes complete with G.I. fittings excludingtrenching and refilling etc. (external work) Rate per METER Medium 15 mm dia. nominal bore 109 Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) 25 mm nominal bore 110 Providing and fixing ball valve (brass) of approved quality, High or lowpressure, with plastic floats complete. 15 mm nominal bore 111 20 mm nominal bore 112 25 mm nominal bore 113 Providing and fixing gate valve1.5 114 Providing and fixing check valve brass 2 115 P/f Pvc connection 24 116 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm)of approved make and quality as per direction of Engineer-incharge. 117 Providing and fixing 15 mm nominal bore of standard back type C.P.brass close hole basin mixer pillar tap of approved quality and make,weighing not less than 1.970 kg. 118 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominalsize), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III): 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mmthick with cement mortar 1:3 (1 cement : 3coarse sand) finished withfloating coat of neat cement and making channels in cement concrete1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mmnominal size) finished with a floatingcoat of neat cementcomplete as perstandard design :20.7.2Inside size 90x80 cm and 60 cm deep including C.I. cover withframe (light duty) 455x610 mm internal dimensions, total weight ofcover and frame to be not less than 38 kg (weight of cover 23 kg andweight of frame 15 kg) :20.7.2.1With common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 119 Extra for depth for manholes Size 90x80 cm 1With common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 120 Providing and laying water proofing treatment on roofs of slabs byapplying cement slurry mixed with water proofing cement compoundconsisting of applying :(a) after surface preparation, first layer of slurry of cement @ 0.488kg/sqm mixed with water proofing cement compound@ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is stillgreen. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @1.289 kg/sqm mixed with water proofing cement compound @ 0.670kg./sqm. and coarse sand @1.289 kg/sqm. This will be allowed to aircure for 4 hours followed by water curing for 48 hours.The entire treatment will be taken upto 30cm on parapet wall and tuckedinto groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which willbe paid for separately)For the purpose of measurement the entire treated surface will bemeasured. 121 Demolishing brick work manually/by mechanical means includingstacking of serviceable material and disposal of unserviceable materialwithin 50 meters lead as per direction of Engineer-in-charge:15.7.4 in cement mortar 122 Brick work with common burnt clay (non-modular) bricks of class designation 7.5 infoundation and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4coarse sand) 123 Extra for brick work with common burnt clay bricks/cement concrete bricks insuperstructure above plinth level upto floor five level 124 Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets. 20 mm dia ( heavy type) 125 25 mm dia ( heavy type) 126 Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:3 ( 1 cement : 3 coarse sand) 127 Cement mortar 1:4 ( 1 cement : 4 coarse sand) 128 Extra for half Brick masonry in superstructure above plinth level upto floor V level. 129 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved makeand shade with 6 mm thick hard board backing. Circular shape 450 mm dia. 130 Rectangular shape 453x357 mm 131 Oval shape 450x350mm (outer dimensions) Please Enable Macros to View BoQ information