| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 17-12-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 24-12-2025 |
| 2 | 06-12-2025 | BOQ | BOQ | 17-12-2025 |
| Sl. No. | Item Description |
| 1 | Demolition of Brickwork or stone / boulder masonry, built in cement mortar or cement lime mortar complete all as specified and as directed. |
| 2 | M & L for full or more brick thick Brick work with fly ash brick, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 using old size brick complete all as specified and directed. |
| 3 | Taking down Cement Plaster of any description on internal surfaces on brick or stone walls or concrete surfaces including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed. |
| 4 | M & L for rendering 15 mm thick cement plastering on wall surfaces in two layers (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4,mixed with liquid water proofing compoundin top layer as per manufacturer\"s instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item). |
| 5 | M & L forrendering 10 mm thick cement plastering on wall surfaces in cement mortar 1:6 onother than fair face of brick-work or concrete surfaceandfinishing the surface even and fair without using extra cement complete all as specified and directed. |
| 6 | M&L for rendering 5 mm thick cement plastering on ceiling surfaces in cement mortar 1:3 on concretesurface, finished the surface even and fair without using extra cement complete all as specified and directed. |
| 7 | Supply onlyliquid water proofing compound complete all as specified and directed. |
| 8 | M&L for preparation of new plasteredsurfaces of walls and applying Two or more coats of 100% Premium acrylic exterior emulsion paint having VOC less than 50 m/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including one priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces as ecommended by the manufacturerall as specified and as directed (Note :(i)After drying of primer coat, surface shall be sanded with zero-grade abrasive paper, ensuring primer is not rubbed off. Surface shall be dusted clean. Emulsion paint shall be applied in accordance with manufacturer\"s instruction.(ii)Rate to include scaffolding and all safety measures at site. ). |
| 9 | M&L for complete removal of existing paint from old decorated surface, preparation ofwall surfaces by washing down, rubbing, and removing stains, including application of Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed.(Note:(i)After drying of primer coat, surface shall be sanded with zero-grade abrasive paper, ensuring primer is not rubbed off. Surface shall be dusted clean. Emulsion paint shall be applied in accordance with manufacturer\"s instruction.(ii)Rate to include scaffolding and all safety measures at site.) |
| 10 | M & L for preparation of new plasteredsurfaces of walls and applying two coats of plastic emulsion paint of any colour as approved by GE over a coat of primer over two mm thick wall care putty complete all as specified and directed. |
| 11 | M & L for preparation of new plasteredsurfaces of ceiling and applying two coats of plastic emulsion paint of any colour as approved by GE over a coat of primer over two mm thick wall care putty complete all as specified and directed. |
| 12 | M & L for complete removal of existing treatment from old decorated wall and applying two coats of plastic emulsion paint of any colour as approved by GE over a coat of primer over two mm thick wall acre putty including preparation of surfaces of complete all as specified and directed. |
| 13 | M & L for 25 mm thick, plain cement concrete 1:2:4,type B-0 (using 12.5 mm graded stone aggregate)as in padding of concrete or levelling course etc and finished the surface even and rough to receive the topping layer complete all as specified and directed. |
| 14 | M & L for cleaning of surface thoroughly from dust &dirt and cement slurry @ 3 Kg / Sqm shall be applied thoroughly. The provide 10 mm thick screed bed in CM 1:4 mixed with integral water proofing compound as per manufacturer\"s instructions, after setting and drying cement mortar, the entire surface of the roof slab shall be cleaned thoroughly to remove all loose particle / dust / dirt particle and applying a coat ofhot blown grade bitumen primer grade 85 / 25 @ 1.20 Kg Par Sqm shall be applied over priming surface. APP based polymeric membrane of minimum weight 3 Kg/Sqmand a minimum 3mm thick reinforced with polyester nonwoven fabric (weight not less than 150gms/Sqm) shall be laidon roofand on vertical surface uptoand insert in grooves and packed in CM (1:3) with overlaps in membrane 100mm,The over laps shall be sealed by flamesor as per manufacturer\"s instructions.and finally it will be finished with two coats of bituminous based aluminium paintincluding taking down of existing roof treatment,properly cleaning & drying the concrete surfaces complete all as specified and directed.(Note: Integral water proofing compound shall be measured and paid separately in Supply only item.) |
| 15 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and disposal ofdebris and rubbish to outside MD land complete all as specified and directed. |
| 16 | M & L for 10cmm thick coloured vitrified tiles, double charged, premium quality,size exceeding 0.42 Sq.m and not exceeding 1 Sq.m,as in floors etc set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile with and including screed bed or bedding layer of 15 mm thick cement mortar 1:4 complete all as specified and directed.(Note: The colour / shade / design of tiles shall be as approved by GE(I).) |
| 17 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 18 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 19 | M&L for 18 to 20 mm thick granite (jet black colour) tiles machine cut as in floors jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing with and including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:6 complete all as specified and as directed. |
| 20 | M & L for glazed, coloured, ceramic, tiles of size (350mm x 250 mm/450mm x 350mm/300mmx450mm) x 6 to 7 mm thick, on vertical surfaces such as skirting, dados etc, including 10 mm thick bedding in cement mortor 1:4 and set & jointed in neat cement slurry & pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 21 | M&L for RCC 1:1.5:3 type A1 (Nominal mix) using 20mm graded stone aggregates as in as in chajja and the like complete all as specified and directed. |
| 22 | M&L forformwork to chulla hoods, chajja etc flat surface , rough finish complete all as specified and directed. |
| 23 | S&F TMT bars 10mmdia and over, cut tolength, bent to shaperequired, includingcranking, bendingspirallyfor hoopingfor columns, hookingends and bindingwith and includingmild steel wire(annealed) not lessthan 0.9mm dia orsecuring with clips complete all as specified and directed. |
| 24 | S&F TMT bars 8mmdiacut tolength, bent to shaperequired, includingcranking, bendingspirallyfor hoopingfor columns, hookingends and bindingwith and includingmild steel wire(annealed) not lessthan 0.9mm dia orsecuring with clips complete all as specified and directed. |
| 25 | Demolition of un-reinforced cement Concrete of any description and in any position not otherwise specifically provided for and removing rubbish to outside MD land complete all as specified and directed. |
| 26 | M & L for 75 mm thick,plain cement concrete1:3:6, type C-1 (using 20mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 including necessary formwork complete all as specified and directed. |
| 27 | M & L for 40 mm thick, plain cement concrete 1:2:4,type B-1 (using 20 mm graded stone aggregate)as in sub-base of flooring, etc and finished the surface even and rough to receive the topping layer complete all as specified and directed. |
| 28 | Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 29 | Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 30 | Taking up or down 25 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 31 | S&F 20 mm CPVC pipes SDR 11 shall be fixed with requisite special type of fittings onwalls(conceled) & ceiling or laid in floors for internal water supply complete all as specified and directed.(Note: Necessary special fittings shall be measured and paid under relevant supply only items.) |
| 32 | S&F 25 mm CPVC pipes SDR 11 shall be fixed with requisite special type of fittings onwalls(conceled) & ceiling or laid in floors for internal water supply complete all as specified and directed.(Note: Necessary special fittings shall be measured and paid under relevant supply only items.) |
| 33 | Supply only 20mm brass elbow for jointing CPVC pipe all as specified and directed. |
| 34 | Supply only 20mm brass elbow (3/4 X ½) for jointing CPVC pipe all as specified and directed. |
| 35 | Supply only 20mm brass Tee for jointing CPVC pipe all as specified and directed. |
| 36 | Supply only 20mmmale brass threaded adaptor (MTA/ MBTA)for jointing CPVC pipe all as specified and directed. |
| 37 | Supply only 20mmfemale brass threaded adaptor (FTA/ FBTA)for jointing CPVC pipe all as specified and directed. |
| 38 | Supply only 20mm Union for jointing CPVC pipe all as specified and directed. |
| 39 | Supply only 20mm tank adopter for jointing CPVC pipe all as specified and directed. |
| 40 | Supply only 25mm brass elbow for jointing CPVC pipe all as specified and directed. |
| 41 | Supply only 25mm brass elbow (3/4 X ½) for jointing CPVC pipe all as specified and directed. |
| 42 | Supply only 25mm brass Tee for jointing CPVC pipe all as specified and directed. |
| 43 | Supply only 25mmmale brass threaded adaptor (MTA/ MBTA)for jointing CPVC pipe all as specified and directed. |
| 44 | Supply only 25mmfemale brass threaded adaptor (FTA/ FBTA)for jointing CPVC pipe all as specified and directed. |
| 45 | Supply only 25mm Union for jointing CPVC pipe all as specified and directed. |
| 46 | Supply only 25mmtank adopter for jointing CPVC pipe all as specified and directed. |
| 47 | S & Fin repair fancy type Bib taps with wall flange, cromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete complete all as specified and directed.Make: Jaquar Cat Part No. FUS-29037 or Equivalent make as per list of Makes in PS. |
| 48 | S & F in repairfancy type Two way Bib taps with wall flange, cromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.Make: Jaquar Cat Part No. FUS-29041 or Equivalent make as per list of Makes in PS. |
| 49 | S & F in repair Wall Mixer 3-in-1 System with Provision for both Hand Shower and Overhead Shower Complete with 115mm Long Bend Pipe, Connecting Legs & Wall Flange complete all as specified and directed. Make: Jaquar Cat Part No. FUS-29281or Equivalent make as per list of Makes in PS. |
| 50 | S & F in repair CP Sink Cock with Provision for Connection to RO from rear side & Swinging Spout complete all as specified and directed.Make: Jaquar Cat Part No. FLR5355N or Equivalent make as per list of Makes in PS. |
| 51 | S & F in repair CP Basin Mixter Single Lever Tall Boy with 150mm Extension Body Fixed Spout without Popup Waste System with 600mm Long Braided HosesMake: Jaquar Cat Part No. FUS-29005NB or Equivalent make as per list of Makes in PS. |
| 52 | S&F in repair Overhead Shower 180mm dia Round Shape Single Flow with Air Effect (ABS Body & Face Plate Chrome Plated) with Rubit Cleaning System complete all as specified & directed.Make: Jaquar Cat Part No. OHS-1755 or Equivalent make as per list of Makes in PS. |
| 53 | S&F in repair Hand Shower 105mm dia Round Shape Single Flow with Air Effect (ABS Body & Face Plate Chrome Plated) with Rubit Cleaning System complete all as specified & directed.Make: Jaquar Cat Part No. OHS-1709 or Equivalent make as per list of Makes in PS. |
| 54 | S&F in repair of CP fancy type angular stopcock 15mm dia with wall flange completeall as specified & directed.Make: Jaquar Cat Part No.FLR-5053N or Equivalent make as per list of Makes in PS. |
| 55 | S&F in repairs PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed. |
| 56 | S&F CP towel ring square with round flange complete all as specified & directed.(Make: Jaquar Cat Part No. ACN-1121N or Equivalent make as per list of Makes in PS.) |
| 57 | S & F in repair Single Towel Rail 600mm Long, Stainless Stee complete all as specified & directed. (Make: Jaquar Cat Part No. ACN 1111SM or Equivalent make as per list of Makes in PS.) |
| 58 | S & F in repair Toilet paper Roll Holder with Stainless Steel Flap complete all as specified & directed. (Make: Jaquar Cat Part No. ACN-1153S or Equivalent make as per list of Makes in PS.) |
| 59 | S & F in repair towel rack with lower hanger (stainless steel) with hook complete all as specified & directed. (Make: Jaquar Cat Part No. AHS-1581H or Equivalent make as per list of Makes in PS.) |
| 60 | S & F in repair Health Faucet spray with 1 Meter Long Easy Flex Tube in Chrome Finish & Wall Hook complete all as specified & directed Make: Jaquar Cat Part No.ALD-565 or Equivalent make as per list of Makes in PS. |
| 61 | S & F in repair bottle trap 32mm size with 300mm & 190mm long wall connection pipes & wall flange complete all as specified & directed Make: Jaquar Cat Part No.ALD-565 or Equivalent make as per list of Makes in PS. |
| 62 | S & F in repair single piece slim concealed cistern body with installation kit & \"P\" type drain pipe connection set for wall hung WC (without flush control plate) complete all as specified & directed Make: Jaquar Cat Part No.JCS-WHT-2400P or Equivalent make as per list of Makes in PS. |
| 63 | S & F in repair rimless Wall Hung WC with inbuilt Jet, PP Soft Close Slim Seat Cover,Hinges, Accessories Set ofSize: 355x555x370 mm complete all as specified & directedMake : Jaquar Cat Part No.FLS-WHT-5953JPPSM or Equivalent make as per list of Makes in PS. |
| 64 | S&F600 mm x 450 mm bevelled edge looking mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood & fixed to wooden plugs with chromium plated brass screws & cup washers. Complete all as specified and directed. |
| 65 | S & F rotational moulded polyethylene water storage tanksof capacity 1000 litres, double layer construction, ISI marked ,(Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one complete all as specified in SSR Part I and as directed. |
| 66 | M&L for PVC (SWR) floor trap, plainwith grating includingjointing with solvent cement including taking down old unserviceable one Complete all as specified and directed. |
| 67 | Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittings heads, shoes, bends, sawn-necks, etc., including cleaning or refixing or removal to store ( measured overall as fixed along the centre line over fittings and accessories) Complete all as specified and directed. |
| 68 | S&F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in trenches complete all as specified and directed. |
| 69 | S&F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 70 | S&F 75mm bore PVC (SWR) bends any type complete all as specified and directed. |
| 71 | S&F 110mm bore PVC (SWR) bends any type complete all as specified and directed. |
| 72 | S&F 75mm bore PVC (SWR) junction single (single \"T\") complete all as specified and directed. |
| 73 | S&F 110mm bore PVC (SWR) junction single (single \"T\") complete all as specified and directed. |
| 74 | S&F 75mm bore PVC (SWR)vent cowl complete all as specified and directed. |
| 75 | S&F 110mm bore PVC (SWR)vent cowl complete all as specified and directed. |
| 76 | Taking down chowkats or frames, exc 1.5 but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame)complete all as specified and directed. |
| 77 | Taking down chowkats or frames, n.exc 1.5 in each with shutter (without taking off shutter from the frame)complete all as specified and directed. |
| 78 | Providing and fixing factory made uPVC white colour sliding window,area not exceeding 2.00 sqm each, three track made of extruded profiles with wall thickness of 2.3mm (+0.2mm). Window profile with hollow section with multi chamber. Frame(88mm x 52mm), sliding sash (42mm x 67mm). Slidingmesh Sash (42mm x 57mm) Sliding interlock (Onevertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cutand fusion welded at all corners, including drillingof holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware.EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners including necessary Hardware like Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories complete all as specified and directed. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose.) |
| 79 | S&F UPVC ventilator with framework made out of multichamber hollow PVC section DWUF 405 (40x46mm) of sintex or equivalent section of other make as per make list. 3mm thick pin headed glass shall be fixed with frame in the lower section using extruded PVC section having a dimension of 9mm x 14.5mm (GL-19 PVC section of Sintex or equivalent section of other make as per make list ) with EPDM gasket (SPL-003 of sintex or equivalent section of other make as per make list) for both the PVC sections. Mullion of ventilator shall be made up of multichamber hollow PVC section DWUF 406 (63.5x40mm) of sintex or equivalent section of other make as per make list, shall be fixed with EPDM gasket. GL-19 or equivalent section shall be fixed to the three side ofDWUF 405 or equivalent and one side of DWUF 406 or equivalent above the centre mulion. Glass panel of aluminium lower set to be fixed to the frame DWUF 405 or equivalent on the top of the ventilator to the glass. DWUF 405 or equivalent and DWUF 406or equivalent corners shall be mitred cut, joineted and welded with 12mm square guard bar complete all as specified and directed. |
| 80 | S & F 4.8 mm thick, sheet glass,ordinary quality and glazing with oil puttyin square n.exceeding 0.5 Sqm in each pane complete all as specified and as directed. |
| 81 | Dismantling wrought iron or mild steel work of any description not otherwise provided for wall complete all as specified and as directed. |
| 82 | S&F for Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors, ladders; framed balusters; walk ways; railings, framework of water tanks and similar work conforming to Fe.290. Gde-E-165 complete all as specified and as directed. |
| 83 | S & F floor door stopper of aluminiumalloy body and tongue, anodised,with hard drawn steel spring,fixed in floor overall length of cover plate 140 mm complete all as specified and directed. |
| 84 | S&F Second class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 85 | S & F 35 mm thick, factory made Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 86 | S & F 35mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., divided into squares, with plain, cham-fered or roun-ded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass etc.as specified in SSR Part I, Section 8 clause 8.24 (a) complete all as specified and directed. |
| 87 | S & F 200 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 88 | S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 89 | S & F aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sectionsor cast aluminium alloy, length of bolt of 300 mm complete all as specified and directed. |
| 90 | S&F 100mm long butthinges,mediumweight, cold rolled mild steel complete all as specified and directed. |
| 91 | S&F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 92 | S & F mild steel bands, straps, supports or stays of rain water, ventilating pipes including bolts, hooks (stay) for large gates, hook and pintel hinges, clamps, hold fasts, wall ties, flat iron fillets for securing wire mesh, wind tie, fan hook and similar work including necessary drillingbolting or riveting etc conforming to Fe – 290 Gde E – 165 complete all as specified and as directed. |
| 93 | M&L plain cement concrete type B0 1:2:4 (using 12.5 mm gradedstone aggregate) for fixing holdfast or similar work with necessary formwork complete all as specified and directed. |
| 94 | M&L for preparing surfaces of wood and wood based materials, steel and iron work, new or old of any description and girth not otherwise described andtreating ends of posts, backs of chowkats, etc. with tar or coal tar or black paint, area tarred exc 0.1 sq. m but n exc 0.5 sq. m each complete all as specified and as directed. |
| 95 | S & F in repairStainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as specified and directed. |
| 96 | S & F in repair300mm long mild steel ordinary rat tailrod pattern springsincluding roller androller plate complete complete all as specified and directed. |
| 97 | M&L for providing and injecting chemical emulsion for post construction anti-termite treatment along the external perimeter of wall below concrete or masonry apronusing chemical emulsion@ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed. |
| 98 | M&L for providing and injecting chemical emulsion for post construction anti-termite treatment of soil under existing floorsusing emulsion @ one litre per hole300mm apart including drilling andplugging 12mm dia holes with cementmortar 1:2 (1 cement: 2 coarse sand) tomatch the existing floors complete all as specified and directed. |
| 99 | Supply, fabrication and fixing of modular kitchen wall carcass (wall Unit carcass) with a minimum 560mm deep over all (approximate), made with Combination of 0.5mm (Body panels) and 1.2mm thick (Horizontal stiffener & leg channels) Galvanized sheet as per IS277.The floor, tall and wall units will be made using sheet metal panels connected with fasteners.Finish on metal surface will be Epoxy polyester powder coating with dry film ofthickness of 50 microns (±10). The shelves and metal hinged door shall be0.5mm thick galvanized sheet complete all as specified and directed.(Note: (i) Front area of the box will be measured flat for payment purpose. (ii) Fitting and fixture accessories required for shall be measured and paid in relevant item. ) |
| 100 | Supply, fabrication and fixing of modular kitchen floor carcass (Floor Unit carcass) with a minimum 560mm deep over all (app), made with Combination of 0.5mm (Body panels) and 1.2mm thick (Horizontal stiffener & leg channels) Galvanized sheet as per IS277.The floor, tall and wall units will be made using sheet metal panels connected with fasteners.Finish on metal surface will be Epoxy polyester powder coating with dry film ofthickness of 50 microns (±10). The shelves and metal hinged door shall be0.5mm thick galvanized sheet complete all as specified and directed.(Note: (i) Front area of the box will be measured flat for payment purpose. (ii) Fitting and fixture accessories required for shall be measured and paid in relevant item. ) |
| 101 | Supply, fabricating and fixing of wall Shutters made out of 12mm thick BWR grade plywood with hardwood core of eucalyptus andor birch specis. The plywood has to be sanded, polished and calibrated before the lamination of acrylic to a thickness tolerance of +/- 0.3 mm. Sanding/ calibration/ polishing has to be done using a wide belt sanding machine of Costa or equivalent brand. The top surface of plywood shall be high gloss after using supermatt acrylic. The acrylic has to be corona treated and cleaned just before lamination process to ensure proper bonding and spotless surface. HOTMELT german PUR glue – Kleiberit made, 711 grade to be used for lamination 1 mm thick polymer. Backer should be used to balance the acrylic board. 0.5/0.6 mm should NOT be permitted to prevent warping. ALL acrylic boards should have protective foil on the front and back surface. The protective foil on the back should have a proper rubber based adhesive to ensure non-stickiness. Only flat laminated acrylic boards manufactured in a controlled clean room environment shall be used . Acrylic boards of approved brand should be used complete all as specified and directed. |
| 102 | Supply, fabricating and fixing of floor Shutters made out of 12mm thick BWR grade plywood with hardwood core of eucalyptus andor birch specis. The plywood has to be sanded, polished and calibrated before the lamination of acrylic to a thickness tolerance of +/- 0.3 mm. Sanding/ calibration/ polishing has to be done using a wide belt sanding machine of Costa or equivalent brand. The top surface of plywood shall be high gloss after using supermatt acrylic. The acrylic has to be corona treated and cleaned just before lamination process to ensure proper bonding and spotless surface. HOTMELT german PUR glue – Kleiberit made, 711 grade to be used for lamination 1 mm thick polymer. Backer should be used to balance the acrylic board. 0.5/0.6 mm should NOT be permitted to prevent warping. ALL acrylic boards should have protective foil on the front and back surface. The protective foil on the back should have a proper rubber based adhesive to ensure non-stickiness. Only flat laminated acrylic boards manufactured in a controlled clean room environment shall be used . Acrylic boards of approved brand should be used complete all as specified and directed. |
| 103 | Supply and fixing of Galvanized steel Shared leg channel for Floor -560Dof Godrej Interio or Make as approved by GE complete all as specified and directed. |
| 104 | Supply and fixing of Galvanized steel END leg channel for Floor-410D of Godrej Interio or Make as approved by GE complete all as specified and directed. |
| 105 | Supply and fixing of Galvanized steel End leg channel for Floor-560D of Godrej Interio or Make as approved by GE complete all as specified and directed. |
| 106 | Supply and fixing of Set of Ball Slides 530mm Long Full Extn. (Regular Closing) type of Godrej Interio or Make as approved by GE complete all as specified and directed. |
| 107 | Supply and fixing of Galvanized steel End Side Cover panel For Floor Unit_410 D_700H of Godrej Interio or Make as approved by GE complete all as specified and directed. |
| 108 | Supply and fixing of Galvanized steel End Side Cover panel Floor Unit_560 D_700H of Godrej Interio or Make as approved by GE complete all as specified and directed. |
| 109 | Supply and fixing of Galvanized steel End Side Cover panel For Wall Unit_310 D_600H of Godrej Interio or Make as approved by GE complete all as specified and directed. |
| 110 | Supply and fixing of Spacer For Gas Cylinder Unit & trolley of Godrej Interio or Make as approved by GE complete all as specified and directed. |
| 111 | Supply and fixing of Waste Bin Holder for Sink Unit of Godrej Interio or Make as approved by GE complete all as specified and directed. |
| 112 | Supply and fixing of Screws, Skirting, Skirting Hardware, Legs & Shelf Support For Metal Kitchen Accessories of Godrej Interio or Make as approved by GE complete all as specified and directed. |
| 113 | Supply of Hardware for shutters hinges (95degrees) and handles 128mm of Godrej Interio or Make as approved by GE complete all as specified and directed. |
| 114 | Supply and fixing of a tranquil Basket of 100mm (530WX100HX510D) of Godrej Interio or Make as approved by GE for modular kitchen complete all as specified and directed. |
| 115 | Supply and fixing of a tranquil Basket of 100mm (830WX100HX510D) for modular kitchen of Godrej Interio or Make as approved by GE complete all as specified and directed. |
| 116 | Supply and fixing of a SS wired Plain Basket of 100mm wide(830WX100HX510D) for modular kitchen of Godrej Interio or Make as approved by GE complete all as specified and directed. |
| 117 | Supply and fixing of a SS wired Plain Basket of 150mm wide(830WX150HX510D) for modular kitchen of Godrej Interio or Make as approved by GE complete all as specified and directed. |
| 118 | Supply and fixing of a SS executive Cutlery tray for modular kitchen. (W 801-900mm X 441-520mm) of Godrej Interio or Make as approved by GE complete all as specified and directed. |
| 119 | Supply and fixing of a SS wired Plain Basket of 100mm wide(530WX100HX510D) for modular kitchen of Godrej Interio or Make as approved by GE complete all as specified and directed. |
| 120 | Supply and fixing of a SS wired Plain Basket of 150mm wide(530WX150HX510D) for modular kitchen of Godrej Interio or Make as approved by GE complete all as specified and directed. |
| 121 | Supply and fixing of a SS executive Cutlery tray for modular kitchen. (W 501-600mm X 441-520mm)of Godrej Interio or Make as approved by GE complete all as specified and directed. |
| 122 | S/F Supply and fixing Frame size 65x 125 mm Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardantand fixed in position with MS hold fast / lugs/ SS dash fasteners of required dia and length complete all as specified and directed. (Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.) |
| 123 | Factory made single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed.(Note: stainless steel butt hinges and necessary S S screws shall be measured and paid separately) |
| 124 | S&F in repairs harrison rails of anodised aluminium alloy,chromiumplatedwith fixing brackets, stops,rollers etccomplete all as specified and directed. |
| 125 | Taking down carefully copper/aluminum existing point wiring (light/fan/socket or power points) complete incl wooden battens/casing capping or conduit etc (without disturbing existing fittings point wiring etc) and all connected fittings such as switch, socket, ceiling rose, lamp holder, brackets ceiling fittings, bulk head fittings and fan regulator etc and making good to disturbed surfaces of wall floor etc all as directed. |
| 126 | Dismantling of old U/S main switches DBs, MCB enclosures, electric meter, PVC rectangular blocks etc and keeping in safe custody either for reuse or for disposal Including making good to the disturbed surface of wall all as directed. |
| 127 | Taking down ceiling / exhaust fan from existing location and deposited to storecomplete all as specified and directed. |
| 128 | M & L for modular point wiring concealedon wall and ceiling/roof etc with necessary fixing arrangements with PVC-FRLS insulated and unsheathed multi-stranded copperconductor of size 1.5 Sqmm, 1100 volts grade drawn through and including rigid non metallicPVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc with captive MS screw including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching/finishing of new surfaces either by means of plaster of perish/ Putty or distemper / colour wash with same existing colour surfaces all as specified and directedfor one Light Point/ Fan Point/ Bell Point complete all as specified and as directedNote: The cost ofcutting chiseling and making good item shall deemed to be included in quoted rate. |
| 129 | All as per item No 128here-in-before but5/6 Amps socket Point on same board. |
| 130 | All as per item No 128 here-in-before but5/6 Amps socket Point on Independent board. |
| 131 | All as per item No 128 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead complete all as specified and as directed. |
| 132 | S&F modular switch 6 Amp, 1 way, 1 module size complete all as specified and directed. |
| 133 | S&F modular switch 16 Amp, 1 way, 1 module size complete all as specified and directed. |
| 134 | S&F Modular socket 6 Amp, 2/3 pin, 2 module size complete all as specified and directed. |
| 135 | S&F modular socket 6A/16 Amp 2/3 pin combined 2 module size complete all as specified and directed. |
| 136 | S&F in repair ceiling modular fan regulator 120 W 2 module size complete all as specified and directed. |
| 137 | S&F ceiling rose surface Polycarbonate/ PVC three terminal complete all as specified and directed. |
| 138 | S&F modular BLANK PLATE , 01 odule size complete all as specified and directed. |
| 139 | S&F modular metal flush box alongwith modular white cover plate including frame , 3 module complete all as specified and directed. |
| 140 | S&F modular metal flush box alongwith modular white cover plate including frame , 6 module complete all as specified and directed. |
| 141 | S&F modular metal flush box alongwith modular white cover plate including frame , 8 module complete all as specified and directed. |
| 142 | S & F in repairs modular AC Box(white), plug and 3 pin socket two in one, all in one type,single pole and neutral box with one single pole MCB 20 Amp 230 Volts complete all as specified and directed. |
| 143 | S&F LEDlights fitting 1x 10W, 220V, AC decorative box type with driver, holder including LED tube light/ batten type connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 144 | S&F LEDlights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light/ batten type connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 145 | S&F LED building security lights fitting 35watt, 230 Volt, outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, bracket of 40mm dia GI pipe light grade 1.50 m long bent to shape as requirred shall be fixed with clamps, nuts, bolts etc to pole or other means, with impact and corrosion resistant including thermal management in multiple optics with IP 65 / 66 protectionincluding connecting up with three core flexible copper conductor cable of suitable size from from existing point complete all as specified and as directed. |
| 146 | S&F ceiling fanof 1200 mm sweep 230 volts, 50 Hz, minimum air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) with and including blades, down rods, electronic regulator and all accessories complete including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 147 | S&F exhaust fan made out of study engineering plastic with and including louvers shutter,of 250 mm size 230 volts, 50 Hz, 1200 RPM, copper winding including all accessories complete including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 148 | Supply, install, testing and commissioning of vertical type MCCB DB, double door, V-TPN 8 way, with MCCB as incommer with and including incomming and outgoing cable with lugs and connection complete all as specified and as directed. |
| 149 | S&F double door metallic sheet metal enclosure for DBs when MCB to be used,SPN, 8 ways 240 Volts (horizontal type)fixed properly on in concealed position and to provide required size of flexible conduit at any open surface near DBs for cable / wires complete all as specified and as directed. |
| 150 | S&F MCCB 4 pole, 415 Volt, adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and as directed. |
| 151 | S&F MCB 40 Amps, TP, 415 Volt \"C\" series, breaking capacity 10 KA completeall as specified and as directed. |
| 152 | S&F MCB 40 Amps, SPN, 240 Volt \"C\" series, breaking capacity 10 KA complete all as specified and as directed. |
| 153 | S&F MCB 40 Amps, SP, 240 Volt \"C\" series, breaking capacity 10 KA complete all as specified and as directed. |
| 154 | S&F MCB 6 to 32 Amps, SP, 240 Volt \"C\" series, breaking capacity 10 KA complete all as specified and as directed. |
| 155 | M&L for sub main wiring with 2 run of Single core FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.00 Sqmm alongwith one run of single core FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.00 Sqmm as earth continuity conductor drawn through and including one run of PVC conduit of suitable size, concealed on wall or ceiling including taking down old unserviceable submain wiring complete all as specified and directed.NOTE : (i) Three runs of single core 4.00 Sqmm cable & one run of PVC conduit shall be measured as one unit.(ii) Cost of cutting chases for concealed wiring shall be deemed to be included in the quoted rates. No claim in this regards shall be entertained at a later stage. |
| 156 | M&L for sub main wiring with 2 run of Single core FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.00 Sqmm alongwith one run of single core FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.00 Sqmm as earth continuity conductor drawn through and including one run of PVC conduit of suitable size, concealed on wall or ceiling including taking down old unserviceable submain wiring complete all as specified and directed.NOTE : (i) Three runs of single core 6.00 Sqmm cable & one run of PVC conduit shall be measured as one unit.(ii) Cost of cutting chases for concealed wiring shall be deemed to be included in the quoted rates. No claim in this regards shall be entertained at a later stage. |
| 157 | Supply and fixing rigid non metallic medium grade 20 mm dia PVC conduit ISI marked in concealed position including all fittings such as bends, elbow, reducer, bell mouth, tube ends and all fixing accessories such as coupler lock, nuts, saddles, pipe hooks etc fixed properly on as in concealed / surface position complete all as specified and directed. |
| 158 | Supply and fixing junction box (1 to 4 way) external dia 20mmcomplete all as specified and directed. |
| 159 | Supply and fixing telephone socket 1 module complete all as specified and directed. |
| 160 | M&L for earthing complete with galvanized steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.0 mm dia bymeans of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No-3 SSR Part -1 2009 connected to earthing test point including earth wire protection pipe of dia 15 mm (medium grage), excavation and earth work, disposal of surplus spoil, provn of RCC cover 50 mm thick, reinforced with 8mm dia TMT bars @100 mm /C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab and PCC (1:3:6) type C-1 concrete pit, funnel with watering pipe 20 mm bore (light grade) testing on completion complete all as specified and directed. [Note : (a)Proper earthing pit should be provided with pit cover. (b) Excavation/earthwork is deemed to be included in the quoted rate.] |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail