| 1 | Taking down cement plaster of any descriptionincluding racking out joints, hacking for key scrubbing down with water etc and removal of debris outside MoD landand depositing where directed. |
| 2 | Demolition of cement concrete (un-reinforced) in ground floor and paving not exceeding 15 cm thick above or below ground level andremoval of entire debris as ordered outside MD land complete all as directed. |
| 3 | Demolition of brickwork , block masonryor stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc and removal of debris as ordered outside MD land complete all as directed. |
| 4 | Taking down chowkats or frames not exc 1.5 sqm each with shutters (without taking off shutters from frame) and stacking at site where directed. |
| 5 | All as per item 4here-in-above but exceeding 1.5 Sqm but not exceeding 4 Sqm each |
| 6 | Dismantling wall and ceiling board fibre pulp,insulation etc or insulation boards any thickness including cover fillets completeall as directed. |
| 7 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 8 | Excavation in trenches and not exe. 1.5 m wide and not exe. 1.5 m in depth for foundation of drain, man hole , laying of UG cablesetc. not exe. 10 Sq. m on plan and not exe. 1.5 m depth and getting out in hard /dense soil complete all as specified and directed. |
| 9 | Returning filling in trenches including spreading, leveling,watering and well ramming in layers not exceeding 25 cm thick in soft rock complete all as specified and directed |
| 10 | Removing excavated surplus soil to a distance not exceeding 50 mtsand depositing where directed .at a level not exceeding1.5 M above the starting point complete all as directed. |
| 11 | M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates and the like including weathering, slightly rounded, chamfered angle and throating as directed including useand waste of form work (straightor curved) all exposed surface of concrete finished fair complete all as specified & as directed |
| 12 | M&L factory made pre cast PCC 1:3:6, type C1 (using 20 mm graded granite aggregate) as in block masonry with solid blocks, exceeding 10 cm in width and setting in CM 1:6 complete all as specified. |
| 13 | All same as per itemNo 12 here-in-above nut not exceeding 10 cm thick -do- |
| 14 | Cutting holes of size Exc. half brick but not exc. one brick in brick walls in brick walls built in cement mortar or cement lime mortar and stone walls built in lime mortarfor insertingholdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 TypeB-1 as required including making good as per its original specification with out any extra costcomplete all as directed. |
| 15 | S&F anodised aluminium powder coated (minimum thickness of powder coating 50 micron) frames, sliding guide channels forshutter for doors, windows and ventilators with one or more rebates including joining cleat for fixing etc. complete all as directed. |
| 16 | S & F powder coated aluminiumdoor shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats ,glazing ,clips, ruber neoprene packing ,handles 02 nos in each door,hinges ,anodised aluminium snap beading screws etc.complete all as specified. |
| 17 | S&F Powder coated aluminium sliding window (three way) frame & shutter with glazed shutter and without miremesh shutter /skeleton section with & including the following:-(i) Aluminium frame section 116x36.50x1.80mm.(ii) Aluminium shutter glazed/skeleton section 50x20x1.50mm thick.(iii) Aluminium grill size 50mmx50mm and 4 to 5mm thick bars complete all as specified.(iv) Fixing arrangements legs in hold fast in walls incl PCC (1:3:6) making goog distributed surfaces complete in originally shape.(v) 4mm thick glass orinary quality and fixed with rubber gasket for with glazed shutter etc.(vi) Stainless steelwire mesh 0.36mm nominal dia avg aperature 1.14mm and fixed with rubber gasket for without glazed shutter etc.(vii) Aluminium disc /bow hanle and locking system complete |
| 18 | S & F in repair mild steel powdercoated body stopper withhard drawn steel spring , 140 mm size fixed todoorcomplete all as specified |
| 19 | M&L for double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed in floor complete all as directed. |
| 20 | S&F in repair 25mm dia aluminium anodised decorative type curtain rods along with brackets & dome. |
| 21 | S&F in repair decorative type curtain rod with brackets & dome . |
| 22 | S&F mild steel framed work as in grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors and similar work including welding conforming to Grade E-165 (Fe 290), complete, all as specified & directed |
| 23 | S & F for 4 mm thick of size 600x600mm Non Asbestos fibre cement building boards fixed for laid / inserted to timber / GI Aluminium frame work ( White colour) to be fixed and including Aluminium snap grid/ section size 600x600 mm duly suspended 6 mm dia GI hangers (1200mm length) adjusting level fixed to roof slab or purlins by means of ceiling cleats made out GI flat 40x3mm size 60mm long and expension holdfasteners 12.5mm dia 40mm long complete all as specified. |
| 24 | M & L for 75 mm thick plain cement concrete 1:4:8 type D2 using40mm graded crushedstone aggregate as insub base ofpath and finished the surface complete all as directed. |
| 25 | M & L for 75 mm thick plain cement conctere 1: 3 : 6type C2 using 40 mm graded crushedstone aggregateas in plinth protection finished the surface fairand even complete all as directed. |
| 26 | M&L for 25 mm thick plain cement concrete 1:2:4 type B0 using 12.5mm graded crushed stone aggregate as in padding / levelling course / subbase of floor etcfloor and finished the surface even & rought complete all as directed. |
| 27 | M&L for 18-20mm thick Sadherhali stone slab flooring, steps, jambs, pillars, window- cills, cooking platforms and like in 20 mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granit laid completeall as directed includingRounding to edges complete. |
| 28 | All same as per item No 37here - in - above but as in dado & skirting with10 mm thick 1 : 3 cement mortar screed - do -(Note for item No 27 & 28 : i) Quoted rateis deemed to be inclusive of cement screed.) |
| 29 | M&L for factory made chequered cement concrete tiles, 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement & pigment, over & including 20mm thick screed bed in cement & sand mortar 1:6, complete all as specified & as directed(Note :Quoted rateis deemed to be inclusive of cement screed.) |
| 30 | M&L for rendering 15 mm thick in CM 1:6 on brick or concrete surfaces or surface other than fair faces brick work, finished even and smooth without using extra cement complete all as specified. |
| 31 | M&L for rendering 15 mm thick in CM 1:4 on brick or concrete surfaces or surface other than fair faces brick work, finished even and smooth without using extra cement complete all as specified. |
| 32 | M&L preparing new plastered wall surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over a coat of 3 mm thick white cement based wall care putty as ordered complete all as specified. |
| 33 | Complete removalofany type ofexixtingtreatment from wallssurfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over a coat of 3 mm thick white cement based wall care putty as specified complete all as specified. |
| 34 | M&L prepration of newly plastered surface ofwallsapplying 3 mm thick white cement based wall care putty , applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal resistance dirt resistance exterior paint (Apex -Ultima Protek) of required shade (company depot tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over newsurfaces applied by mechanicalmeans i.e Airless spray including filing undulations with white cement based putty mixed with multi purpose mixer complete all as directed. |
| 35 | Complete removal of any type of earliertreatment from any surface ofwallsapplying 3 mm thick white cement based wall care putty , applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal resistance dirt resistance exterior paint (Apex -Ultima Protek) of required shade (company depot tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over newsurfaces applied by mechanicalmeans i.e Airless spray including filing undulations with white cement based putty mixed with multi purpose mixer complete all as directed. |
| 36 | Supply only 5.50mmthick sheet glass ordinary quality in square/rectangular in each panes. |
| 37 | M&L for preparing surfaces of wood and wood based materials, new or old, of any description and girth not otherwise described and treated with two coats of creosote oil complete all as specified |
| 38 | E&M : Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing taken down materials to a place where ordered for crediting includingmaking good disturbed surfaces of walls, floors, etc to match with the existing surface complete all as directed.. |
| 39 | Point wiring with PVC insulated and unsheathed FRLS cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS-694 1990 drawn in and including PVC rigid non metalicconduit (Medium Grade) concealed in wall conforming to IS-9537 with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3mm thicklaminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for :-(a) One light / Fan / bellpoint controlled by one 5 Amps switch one way |
| 40 | (b) One 3 pin socket point 5/6 Amp on independent board |
| 41 | (c) One 3 pin socket point 5/6 Amp on same board with other switches.(to be provide new point as user requirement) |
| 42 | All as per item No. 39 here-in-above but with 2.5sqmm ( Nominal area ) cable with 2.5 Sqmm size copper earth continuity conductor for 3 pin 15/16 A socket outlet on independent board complete all as specified and directed. |
| 43 | Supply and fix Switch piano, flush button single pole, 5 Amps one way. |
| 44 | Supply and fix Switch sokcet combination flush type 5 Amp 2/3 pin muliti purpose |
| 45 | Supply and fix Switch socket combination flush type 6/16 Amps 3/3 pin universal multipurpose |
| 46 | S&Fceiling rose surface bakelite White / Ivory / Urea finish50 mmdiathree terminals including supply and fix PVC square mounting block complete all as specified and directed. |
| 47 | Supply and fixfan regulator electronic , step& socket type 230 volts , suitablefor 1200 /1400 mm sweep ceilingfancompleteall as directed. |
| 48 | S&F LED tube light fitting of20 watts 6000K , 230 volt, withaluminium extruded channel powder coated with diffuser for glare free light complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. |
| 49 | S&Fof LEDLuminarire 600mmx600mm 35/36 Watt , 230 volt, with recessed type with high efficiencyPMMAdiffuser soft glare free light complete with driver holders & LED lamp suitable for roof ceiling includingconnecting up with three core flexible copper conductor cable of size 24/0.20 sqmm ,complete all as specified and directed. |
| 50 | S&F bldg security lightfittings 1x 35 Watt Ac 230v out door typeLED street light with high pressuredie cast aluminium and heat ressistent complete with driver ,lamp bracket with impact and corrosion resistentincluding thermal managment in multiple optics complete, IP65/66 and wired with all accessories and including connection up with twine core twisted flexible copper conductor cable with 1.5 M long suitable size all as specified and directed. |
| 51 | S&F street light bracket made out of 25 mm bore GI Light grade 1.00 M long to required shape as in bracket for steet light fittings fixed with two pair of MS flate iron clamp of size50mm X 6 mm thickness of required shape with nuts, bolts and washers suitable for steel tubular pole including painting of mild steel flate iron surface with two coates of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 52 | S&Fsubmain wiring with 2 runs of 4 Sqmm single core PVC insulated, unsheathed, multi strandedcopper conductor and one single core 4 Sqmm PVC insulated , unsheathed , multi strandedcopper cable as earthing lead as per IS : 694 / 1990 drawn through and includingnon-metallic PVC rigid conduit/casing caping of size as orderedin walls / ceilings etc with all accessories such as Tees, Elbows, junction box, reducers etc and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion complete all as specified and directed. (Note :- 2 runs 4 Sqmm cable , one run 4 Sqmmcableand one run of PVC Conduit /Casing caping shallbe measured as oneunit length) . |
| 53 | S&Fsubmain wiring with 2 runs of 6 Sqmm single core PVC insulated, unsheathed, multi strandedcopper conductor and one single core 6 Sqmm PVC insulated , unsheathed , multi strandedcopper cable as earthing lead as per IS : 694 / 1990 drawn through and includingnon-metallic PVC rigid conduit/casing caping of size as orderedin walls / ceilings etc with all accessories such as Tees, Elbows, junction box, reducers etc and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion complete all as specified and directed. (Note :- 2 runs 6 Sqmm cable , one run 6 Sqmmcableand one run of PVC Conduit /Casing caping shallbe measured as oneunit length) . |
| 54 | S&F Sheet metal enclosure (ISI marked) distribution board for 415 volts, TPN4 way Vertical type, doubledoor, triiple pole and neutral with incomingMCCB 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as directed.(Note: MCCB measured & paid seperately ). |
| 55 | S&F Sheet metal enclosure (ISI marked) distribution board for 240 volts, SPN8 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as directed. |
| 56 | Supply and fix in repair MCB Tripple pole & neutral 40 to 100 Amps 415 volts, C series,10 kA rupturing capacity providing in DB complete all as specified. |
| 57 | S & FMCB single pole 6 to 32 Amps 240 volts, \"C\" Series 10 kA rupturing capacity providing in DB completeall as specified and directed by Engr-in-charge. |
| 58 | S & FMCB single pole & neutral 40 Amps 240 volts, \"C\" Series10 kA rupturing capacity providing in DB completeall as specified. |
| 59 | M&L for taking down and dismantling of ceiling fan 1200mm/1400mm sweep 230 Volt 50 C/S AC of any make or model by opening the cover, separating down rod, rotor and stator assembly, locating the fault and making the fan fully in serviceable condition with & including replacing the bearing withsimilar type of exisitng one, worn out screws of the cover, split pin, twin core flexible copper wire of size 23/0.0076, locking nuts & machine screws with spring washer for ceiling fan blades, oiling and greasing including rewinding of ceiling fan by removing of burnt winding from stator and rewinding the same with super enamelled copper winding wire of same gauge, same weight & turns including varnishing of winding etc &finally painting the ceiling fan with one coat of spray painting with white DUCO Paint & lettering & Numbering the same as per existing ,reassembling , refixingthe same in same or different location asordered & finallytesting the fan ,complete all as directed.Note : (i) Spare Parts/accessories found unserviceable includingbearings , rewinding etc which are required to makethe fan functional shall be providsed by thecontractorwithout any extra cost toGovt as quoted rate isdeemed tobe inclusive forthesame .(ii) Quoted rate isdeemed tobe inclusive ofpainting . |
| 60 | M&L for Sand cushioning/sand coveringfor underground cable protection complete all as specified.Note: Punned thickness only will be measured and paid. |
| 61 | Supply and laying sub class \"B\" bricks of old size (standard size as per local availability) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge |
| 62 | S&Fmild steel galvanized pipe light gradefor protection &passing of LT cable fixed to poles/walls/laid under floor/roads complete including fittings/clamps as required at site all as specified for size of 50mm bore dia. |
| 63 | Supply, fixing ,Teting and commissioning XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty) with stranded aluminum conductor, 1100Volt grade on walls with fixing acessories of25 Sqmm 4 Core all as specified and directed. |
| 64 | M&L, Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.0mm thickburied directly in ground (earth pit depth not less than 2.25m deep below the ground level) with top edge of earth plate at a depth not less than 1.5m below ground level connected to earth using GI earth wire of 4 mm dia by means ofof nuts, bolts and washer and check nuts of GI or steel as shown in electrical plate No.3 of MES SSR-2009 (Part-I) and connected to earth test point all as specified or indicated including testing on completion with and including 15mm bore light grade GI protection pipe 7.5 metre long for earth including PCC (1:2:4) pit with RCC (1:2:4) type B-1 cover, 40mm thick reinforced with 6mm dia MS bars @ 100mm both ways with lifting hooks made out of 6mm dia MS bars, watering arrangement with 20mm dia light grade pipe, funnel, wire mesh, common salt chorcoal, necessary excavation and earth work in any type of soil complete all as specified. |