| 1 | BUILDING & STRUCTURE (Sch \"A\" PART-I) |
| 2 | Lump sum price worked out by the Contractor for “BUILDING & STRUCTURE”as listed in Schedule ‘A’ Part-I.Representing ** ___ % ______ percent *Above / Below the lump sum price of2,03,83,424.93 inserted by the MES in Schedule ‘A’ Part-I. |
| 3 | SITE CLEARANCE AND SITE DEVELOPMENT (Sch \"A\" PART-II) |
| 4 | Lump sum price worked out by the Contractor for “SITE CLEARANCE AND STIE DEVELOPMENT”as listed in Schedule ‘A’ Part-II.Representing ** ___ % ______ percent *Above / Below the lump sum price of5,98,263.62 inserted by the MES in Schedule ‘A’ Part-II. |
| 5 | INTERNAL WATER SUPPLY (Sch \"A\" PART-III) |
| 6 | Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-III.Representing ** ___ % ______ percent *Above / Below the lump sum price of2,96,520.18 inserted by the MES in Schedule ‘A’ Part-III. |
| 7 | INTERNAL ELECTRIFICATION (Sch \"A\" PART-IV) |
| 8 | Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION”as listed in Schedule ‘A’ Part-IV.Representing ** ___ % ______ percent *Above / Below the lump sum price of12,74,716.74 inserted by the MES in Schedule ‘A’ Part-IV. |
| 9 | ROAD, PATH, CULVERT (Sch \"A\" PART-V) |
| 10 | Lump sum price worked out by the Contractor for “ROAD, PATH, CULVERT”as listed in Schedule ‘A’ Part-V.Representing ** ___ % ______ percent *Above / Below the lump sum price of15,39,758.71 inserted by the MES in Schedule ‘A’ Part-V. |
| 11 | SEWAGE DISPOSAL (Sch \"A\" PART-VI) |
| 12 | Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL”as listed in Schedule ‘A’ Part-VI.Representing ** ___ % ______ percent *Above / Below the lump sum price of13,83,913.79 inserted by the MES in Schedule ‘A’ Part-VI. |
| 13 | AREA DRAINAGE (Sch \"A\" PART-VII) |
| 14 | Lump sum price worked out by the Contractor for “AREA DRAINAGE”as listed in Schedule ‘A’ Part-VII.Representing ** ___ % ______ percent *Above / Below the lump sum price of5,92,962.38 inserted by the MES in Schedule ‘A’ Part-VII. |
| 15 | EXTERNAL WATER SUPPLY (Sch \"A\" PART-VIII) |
| 16 | Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-VIII.Representing ** ___ % ______ percent *Above / Below the lump sum price of64,457.20 inserted by the MES in Schedule ‘A’ Part-VIII. |
| 17 | EXTERNAL ELECTRIFICATION (Sch \"A\" PART-IX) |
| 18 | Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION”as listed in Schedule ‘A’ Part-IX.Representing ** ___ % ______ percent *Above / Below the lump sum price of2,85,159.63 inserted by the MES in Schedule ‘A’ Part-IX. |
| 19 | SOLAR WATER HEATER/HOT WATER SUPPLY (Sch \"A\" PART-X) |
| 20 | Lump sum price worked out by the Contractor for“SOLAR WATER HEATER/HOT WATER SUPPLY”as listed in Schedule ‘A’ Part-X.Representing ** ___ % ______ percent *Above / Below the lump sum price of93,865.86 inserted by the MES in Schedule ‘A’ Part-X. |
| 21 | MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch \"A\" PART-XI) |
| 22 | SITE CLEARANCE AND SITE DEVELOPMENTSupply only approved earth from outside Md land incl. roalty etc. from a distance of 5 km |
| 23 | INTERNAL ELECTRIFICATIONS & F LED ADORE 5 W B22 CDLwith B 22 base capacity 1200 lumencomplete all as specified. |
| 24 | S & F LED INVERTER Rechargeable BULB 12WattCDLwith B 22 base capacity 1200 lumenwith backup of minimum 5 hrs backup complete all as specified. |
| 25 | S & F sheet metal enclosureVTPN 04 wayDouble door Ready to use DBs - Provided with insulated vertical phase bus-bars |neutral bar/s with shroud/s | earth bar/s | sticking saddles | cement spill protector | color-coded interconnecting wire set | cable ties | blanking plates and circuit identification labels With provision for4 Pole MCCBas incomer and SP/SPN/TPNMCBs as outgoing complete all as specified and directed. |
| 26 | S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and PC Cover having TOP opening seperate driver compartment with IP 66 Protection and impact resistance of IK07 with electronic driver of capacity 20 watts with pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade of aqequate dia 1.5 mtr long bend to required shape complete all as directed by Engineer-in-Charge. |
| 27 | S&F in repairs trim Cosmo surfaceround slim surface mounted LED panel light 12Watt ,6500K with premium diffuser to ensure glare free & even light distribution including surface module accessories andcomplete incl removal of old unsv fitting all as specified and as directed. |
| 28 | Supply ,Installation ,Testing & Commissioning of AC whole current, Single phase, Two wire, tamper proof,Smart Energy Meters with prepaid and postpaid facility, 240 Volts, 50 HZ, 10-60 Amps; with plug and play type and field swappable communication module; with LED/LCD Data display; manufactured confirming to IS 16444 & with BIS identification mark on Name Plate, with sealing arrangement as per relevant IS; Transparent Meter Box; with standard sealing material as required at site.Numer of such Meters along with meter box of four different makes out of Approved makes in MES. |
| 29 | Supply ,Installation ,Testing & Commissioning of AC whole current, Three phase, Four wire, tamper proof,Smart Energy Meters with prepaid and postpaid facility, 415 Volts, 50 HZ, 10-60 Amps; with plug and play type and field swappable communication module; with LED/LCD Data display; manufactured confirming to IS 16444 & with BIS identification mark on Name Plate, with sealing arrangement as per relevant IS; Transparent Meter Box; with standard sealing material as required at site.Numer of such Meters alongwith meter box of four different makes out of Approved makes in MES. |
| 30 | Installation of Meter Data Management System (MDM) is to be set up to support storage, archiving, retrieval & analysis of meter data and various other operational systems along with validation & verification algorithms. |
| 31 | S & F in repair Smart Fan Rod or Anti Suicide Fan Rod for ceiling fans 1200 /1400 mm sweep having following specifications /sizes in white color, Thickness of Rod = 1.84(+/-0.05) mm on zinc plated MS Pipe with zinc plated spring mechanism, MSME Tested for 15 Kg weight bearing capacity and breaking at impact load of 22Kg+ including drilling,mounting,brackets,anchors etc(If required) , the fan down rod opens from its center and spring hidden in pipe, expands to land person on ground safely complete all as specified and as directed by Engr-in-Charge. |
| 32 | Supply and Fix Heavy Duty Wall Mounted Turbo Air Circulator Metal Blade Heavy duty fans AC 230Volts Single Phase 400 mm Sweep complete with all accessories such as fast nuts and bolts duly clamped on walls including all mounting arrangement fan base complete all as specified and directed . |
| 33 | SEWAGE DISPOSALSupply, laying and testing of 200mm internal dia of DWC high density(HDPE) pipe ISI marked (with CM/L No) with and including all fittings and jointing materials for sewage line and laid in trenches as specified. |
| 34 | EXTERNAL ELECTRIC SUPPLYBoring holes horizontally under Road without damaging the surface of Road (minimum 1.0 METRE below the Road Surface incl GI Tubing not exc. 80mm bore (dia) for passing of UG Cable, complete all as specified and as directed. |
| 35 | S & F Junction Box for Street Lights of size 205x255x112 mm made out of Polycarbonate material totally enclosed, dust and vermin proof, rain protected slanted roof top, door pasted with rubber gasket, water tight IP 66/67 protection and suitable size of \"connectwell\" stud teriminal (provision for socket bolting)- 04 Nos suitable for 415 volts, 50 Hz, 3 phase 4 wire internal wiring system including MCB SP 06 amps- 02 No and mounted on security light pole with suitable bracket nuts, bolts including removal of exiting unsv all as specified . |
| 36 | Supply & laying , testing & commissioning of LT PVC insulated, 3 core copper Conductor 1100 Volt grade, cross-sectional area 1.5 Sqmm 3 core, connecting along security pole from Junction Box to Security lightetc , complete all as specified and as directed. |
| 37 | Supply & Fixing street light bracket made of 32mm dia GI Pipe light grade upto 1.2mtr including two pairs of clamps made out of flat iron 40mm X6mm of sutable length complete all as specified and directed. |