| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-12-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 23-12-2025 |
| Sl. No. | Item Description |
| 1 | Demolition of brick/stone masonry built in cement/lime mortar of any mix including all quoins pillar ashlars masonryand removal complete all as specified & directed. |
| 2 | M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 3 | M&L Brick work with FLY ASHbrick straight or curved on plan to any radius in half brick thick walls built inCM 1:4 complete all as specified & directed. |
| 4 | M&L for walling of random rubble,bedded and solidely hearted Uncoursedbuilt in CM (1:6) complete all as specified and directed. |
| 5 | Extra over stone walling for hammer dressed to face stores and dressing of face beds and joints as specified of random rubble walling uncoursed or brought upto course with maximum deprssion on face from straight adge held against the depressed surface on lime or sand stone not exc 20mm for rock faced complete all as specified & directed. |
| 6 | Demolition of cement concrete (un-renforced) in ground floor and paving not exc. 15 cm thickness(below or above ground level.) & removal of rubbish material complete all as specified & directed. |
| 7 | M&L for PCC (1:2:4) type B-1 (using20mm graded stone aggregate), 25mm thick, as in Sub base complete all as specified & directed. |
| 8 | M&L for coloured non skid vitrified ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed. |
| 9 | M&L non skid ceramic tiles colored 300x300x7mm thick in floor set and jointed in neat cement slurry and pointed in white or coloure cement and over 15mm thick screed bed in CM 1:6 complete all as specified & directed. |
| 10 | Dismantling floor,hearth or wall tiling incl cement mortar bedding (but ot backing), removing serviceable tiles to store and rubbish off the premises complete all as specified & directed. |
| 11 | M&L Glazed ceramic coloured tiles in vertical surface450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tiles and over 10 mm thick rendring in cm 1:4 complete all as specified & directed. |
| 12 | M&L machine cut kota stone slab flooring 18-20mm thick over20 mm thick screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified & directed. |
| 13 | M&L machine cut kota stone slab 18-20mm thick in steps for riser, dado, skirting, wall etc over20 mm thick screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified & directed. |
| 14 | M&L for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including cutting and polishing types andover screed bed 20 mm thick CM1:6 cement concrete complete all as specified & directed. |
| 15 | M&L 75 mm thick PCC(1:3:6) type C1 (using 20mm graded stone aggregate ) as in plinth protection finished fair and even complete all as specified & directed. |
| 16 | Taking down cement plaster any description on brick or stone walls etc complete all as specified & directed. |
| 17 | M&L rendering 10mm thick in cement mortar 1:6 on fair faces of stone masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified & directed. |
| 18 | M&L for rendering 15mm thick in CM 1:4 on stone wall surfaces or other than fair faces of brick work & surfaces finished even and smooth without using extra cement with water proof compound (water proof compound paid seperatly) complete all as specified & directed. |
| 19 | Supply only Integral waterproofing compound complete all as specified & directed. |
| 20 | All as per srl item No 19.00 but 5 mm thick in CM 1:3 over ceiling. |
| 21 | M&L for Rough cast plaster on exterior wallsapplying the under coat of cement and sand morrtar 1:3 not less than 10mm thick and while it is still in plastic state the roughcast mixture consisting of crushed stone or fine gravel aggregate (size between 6 to 12mm ) mixed with coarse sand and cement in the raio of 1:1:1 shall be applied and finished even.The mix of cement and sand shall made slightly wetter than normal for rendering to ensure that larger aggregate are thoroughly covered completeall as specified and directed. |
| 22 | M&L for preparation of new plastered surfaces of walls and applying two coats of Oil bounddistemper overa coat of 1 mm thick wall care putty of approved tint complete all as specified & directed. |
| 23 | M&L for preparation of newly plastered surfaces of wall and applyingthree coats of white wash complete all as specified & directed. |
| 24 | Providing and applying wall care putty of 1 mm thickness over plastered/unplastered surface to prepare the surface even and smooth complete all as specified & directed. |
| 25 | M & L for preparation of newly plastered surfaces of walls and applying two coat of exterior emulsion apex paint (exterior grade) over one coat primer over 1mm putty on walls complete all as specified & directed. |
| 26 | M&Lfor preparation of newly plastered surfaces & applyingthreecoat of white wash on ceiling complete all as specified & directed. |
| 27 | M & L for complete removal of existing treatment on wallsand preparation of new/old surfaces of walls and applying two coat of exterior emulsion apex paint (exterior grade) over one coat primer over 1mm putty on walls complete all as specified & directed. |
| 28 | M & L for complete removal of existing treatment on walls applyingtwo coatsof oil bound distemperover a coat of 1mm thick wall care putty complete all as specified & directed. |
| 29 | M&L for preparation of old plastered surfaces of wall and applyingone coats of white wash complete all as specified & directed. |
| 30 | M&Lfor preparation of old plastered surfaces & applyingone coat of white wash on ceiling complete all as specified & directed. |
| 31 | M&L for complete removal of existing treatment on wallsand preparation of surfaces of walls and applying two coat Plastic emulsion painton walls complete all as specified &directed. |
| 32 | Treatement for sunken portion is as follows :-(i) Demolition of lean concrete and other type of filling in sunken portion & cleaned the sunken portion incl vertical wall surface complete as directed.(ii) M&L for providing 12 mm dia holes of 40mm deep @2.00m c/c at junction of beams and columns as co-ordinal points for inserting/pouring cement slurry by pressure grouting for sunken floors of toilet , includind sealing the holes with CM 1:3, all as specified and as directed .(iii) M&L for water proofing plaster for sunken portionin CM 1:3, 20 mm thick in two coats with water proofing compound at the rate of 2% by weight of cement and finishing the surface even and smooth without using extra cement.(WPC will be measured and paid seperately).(iv) M&L for applyin evenlytwo coats of industrial bitumen 85/25 at the rate of 1.20 Kg/Sqm in each coat over vertical surfaces and floors of sunken floors of toilet including cleaning of surfaces.(v) M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in filling (sunken portion). etc. |
| 33 | Demolition Mud in roofs, any thicknes, including plastering , existing tretement and cleaning (whether full thickness removed or only or part there of)etcin all respect and preparing it for further treatment and taking out and disposal of debris & rubbish to a distance exc 1 Km but not exc 1.5 Km complete all as specified & directed |
| 34 | M&L Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified& directed. |
| 35 | M&L rendering 15mm thick in CM 1:4with water proofing compound over green concrete surface (WPC will be measured and paid seperately) surface finished even and smooth (without using extra lime or cement) complete all as specified & directed. |
| 36 | M&L Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq. mincluding cleaning surfacesover bituminious primer complete all as specified& directed. |
| 37 | M&LAPP based plymeric membrane minimum weighing 3 Kg/Sqm and minimum 3 mm thick reinforced with polyster non woven fabric (wt not less than 150 gms/sqm) land on primed surface by forced application complete all as specified. |
| 38 | M&L for PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) as in roof padding,laid to a minimum consolidated thickness of 25 mm as leveling course, laid and compacted inmin slope 1:30 over roof complete all as specified& directed. |
| 39 | M&L for applying bitumious aluminium paint @ 0.15 kg per Sqm over bituminous layer in two coats complete all as specified and as directed. |
| 40 | M&L 50mm thick Sand stone slabs in sunshades, chajjas, shelves, cills, landings, cover stones, templates, etc, n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4,complete all as specified & directed. |
| 41 | M&L precast cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) set in cement mortar 1:6 as in coping of brick masonry wall kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin) corbels, brackets, etc. including weathering slightly rounded or chamfered angles and throating as directed including necessary formwork complete all as specified & directed |
| 42 | Cutting holes in stone walls in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 exc half brick wall complete all as specified & directed. |
| 43 | Taking down chowkatts or framesn exc 1.5 sqm each complete all as specified & directed. |
| 44 | Taking down chowkatts or framesexc 1.5 sq. m but n exc 4 sq m each complete all as specified& directed. |
| 45 | M&L Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing. |
| 46 | M&L for Mild steel angle iron door frame 40mmx40mmx5mm conforming to Fe 410-0 (Gde-E-250 ) incl 12mm dia deformed bars for strengthing at bottom of chowkhats incl cutting floor at bottom to accommodated strengthing bars & making good the floor in PCC 1:2:4 type B-0 to match the existing floor complete all as specified& directed. |
| 47 | S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintel hinges; largehasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps,plate washers and similar small articles conforming to Fe410-0 or Fe 310-0 complete all as specified & directed. |
| 48 | S&F 35mm thick IInd class hard wood factory made panelled door shutter(two panel) with lock rail and panelof 9mmBWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. the size of rail and stiles as per IS: 1003 (part-I), kiln seasoned and chemically pressure treated and fixed to chowkats complete all as specified & directed. |
| 49 | S&F 35 mm thick 2nd class hard woodGlazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.24 (a); supplied and fitted to chowkats complete all as specified& directed. |
| 50 | M&L Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site complete all as specified & directed. |
| 51 | M&L 25mm thick Prelaminated particle board, interior grade, prelaminated one side with deocrative choice lamination & other side balancing white lamination, fixed with screws to timber frame workcomplete all as specified & directed. |
| 52 | M&L for preparation of new wooden surfaces over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified& directed. |
| 53 | M&L for preparation of old wooden surfaces over 10cm width or girth andapplying one coat of synthetic enamal paint (of approved shade) complete all as specified& directed. |
| 54 | S&F Butt hinges 100mm long medium weight, colled rolled mild steel complete all as specified & directed. |
| 55 | S&F Butt hinges 75mm long medium weight, colled rolledmild steel for Prelaminated doors complete all as specified& directed. |
| 56 | S&F 150mm Aluminium, anodised, barrel tower bolts of extruded section and fixedcomplete all as specified & directed. |
| 57 | S&F 150mm Aluminium handles, cast type, anodised complete all as specified & directed. |
| 58 | S&F 300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixedcomplete all as specified & directed. |
| 59 | S & Fixed 300mm Helical/rat tail door Spring 300mm size with MS sheet wing pattern including roller plate complete as directed. |
| 60 | S&F 18/19mm thick Prelaminated particle board, interior grade, prelaminated one side with deocrative choice lamination & other side balancing white lamination, fixed with screws to timber frame work etc. including taking down existing frame work complete all as specified & directed. |
| 61 | S&F in repair stainless steel drapery rod 25mm dia (in lengths directed) of approved colour with and including decorative bowel at both ends and pair of power coated stainlesssteel brackets fixed at both ends with pvc Rawl plug and steel screwed on walls/beamcomplete all as specified & directed. |
| 62 | S & F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanized wire staples complete all as specified and directed. |
| 63 | S&FStainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified. |
| 64 | S&F in repairfor pressed steel shutter 1mm thick including pressed steel frame of 1.25 mm thick sheet, 12mm dia MS rod for locking, two Nos chromium plated handle and one Godrej pattern lock including two coat of spray painting over a shop coat of primer, complete, all as shown in Drg No. TD/2004/29 sheet No. 1/3 to 3/3 |
| 65 | S&F anodized aluminium frame and other sections for doors, windows, ventilators, partitions, powder coated of any colour as approved (Thickness or powder coating not less than 50 micron) with one or more rebates including joining cleat for fixing etc. complete all as specified & as directed. |
| 66 | S&F anodized aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m, powder coated of any colour as approved (Thickness or powder coating not less than 50 micron) including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 Nos), suitable handle (1 No.) complete all as specified & as directed. |
| 67 | S & F for powder coated (minimum thickness of powder coating 50 micron) anodised aluminium grill of approved pattern for windows/ ventilators/doors complete all as specified and directed. |
| 68 | Supply only sheet glass ordinary quality,in squares n. exc. 0.5 SQM each 4.80 mm thick complete all as specified & directed. |
| 69 | S/F in repair kitchen sink without draining board made out of stainless steel 1mm thick with plugs, washers and waste pipe including bedding in cement mortar to dwarf wall or including and fixing cast iron cantileverbrackets and connecting union to pipe over all size 495x420 mm bowl size 410x330x160 mm including flush pipe of polyethylene of low or high density or PVC 32mm bore with long screwed shanks and fly nutscomplete all as specified & directed. |
| 70 | S&F Stainless steel plate rack, 1.00mm thick for kitchen size 600x900x230mm complete all as specified & directed. |
| 71 | S&F in repair PVC connection pipe, 15mm dia & 600mm long with adopter and washer at both end complete all as specified & directed. |
| 72 | S&F Rotational moulded polyethylene water storage tanksof 500 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I includingdismantling water tanks complete all as specified & directed. |
| 73 | S&F ball valves brass high pressure with polythelene float and fly net complete, screwed , iron pipes 20 mm dia complete all as specified & directed. |
| 74 | S&F brass Gun-metal, globe or gate valves 20mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 75 | Taking up or down 15mm steel tubing and connections, complete all as specified & directed. |
| 76 | Taking up or down 20mm steel tubing and connections, complete all as specified & directed. |
| 77 | S&F steel tubing medium grade 15mm bore with all fittings fixed complete to wall and or laid in floorcomplete all as specified & directed. |
| 78 | S&F 20mm GI tubing Medium grade fix to wall/floor complete all as specified & directed. |
| 79 | S&F in repair fancy type bib taps, chromium plated alloy with crtuch or butterfly handle,screwed down, screwed for iron pipe or for brass ferrule and fixed omplete all as specified & directed. |
| 80 | S&F white vitreous china wash hand basin \"Flat back\" of size 550x400mm fixed on and including new brackets CPwaste coupling and PVC Waste pipe complete all as directed. |
| 81 | S&F 15mm dia CP pillar tap fancy typecast copper alloy, CP with capstan head, screwed ddown high pressure, with or without lettered \"HOT\" or \"COLD\" with long screwed shank and fly nuts screwed for iron pipe and fixed complete all as directed. |
| 82 | S&F in repair wall mixer chromium platedcomplete cast copper alloy, chromium plated, scrwed downhigh pressure, complete all as specified & as directed. |
| 83 | S&F in repair Stop/angle valves,fancy type, chromium plated alloy screwed down high presure, screwed both ends for iron pipe or for unions of 15 mm diacomplete all as specified & directed. |
| 84 | S&F Towel rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms) complete all as directed as specified & directed. |
| 85 | Cutting holes into or through brick but in brick walls built, in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of limeEx 150 sq. cm but n exc 400 sq. Cm (not excluding 25CM depth) for cooler stand complete all as specified & directed. |
| 86 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified & directed. |
| 87 | S/F in repair Vitreous China Squatting pan, Orissa pattern, size 580 x 440mm white with integral foot rests connection to trap and to flushing pipe,etc.complete including making food to floor complete all as specified & directed . |
| 88 | S&F in repairs PVC low level flushing cistern 10 litrs capacity (white ISI marked) with inlet ball valve,float and handle, syphonic action type including brackets and flush pipe of polythelene of low or high density of PVC 32mm dia for LLFC make Dolfine/Commander Champion, fixed in repairs, complete all as specified. |
| 89 | S&F in repair PVC (SWR) pipes 110 mm bore single socketed, in any length with rubber ring joints laid in trenches or in floorscomplete all as specified & directed. |
| 90 | S&Fin repair PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified & directed. |
| 91 | S&Fin repair PVC (SWR) pipes 75 mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified & directed. |
| 92 | S&F in repair PVC (SWR) bends any radius 110 mm bore complete all as specified & directed. |
| 93 | S&F in repair Grating doom 100 mm dia of PTMT (Minimum weight 25 gms)fixed with cementcomplete all as specified & directed. |
| 94 | S&F PVC (SWR) vent cowl 110mm complete all as specified & directed. |
| 95 | S&F in repair 75mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified & directed. |
| 96 | S&F in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cementcomplete all as specified & directed. |
| 97 | S&Fin repair PVC (SWR),110mmjunction single, (Single T) equal or unequalcomplete all as specified & directed. |
| 98 | M&L writing letters or figures(Block,roman,Italic or Indian letter n.exc 30cm high) complete complete all as specified & directed. |
| 99 | S&F brass chromium plated shower rose 125mm size with swivel joint type including fixing to steel pipe of 15mm bore or union complete all as specified. |
| 100 | Dismantling framed timber scantlings 40 sq. cm and over in section, in any position complete all as specified & directed. |
| 101 | Dismantling wrought iron or mild steel work of any description not otherwise provided for any work complete all as specified and directed |
| 102 | S&F for Hard drawn steel wire fabric cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemntcomplete all as specified & directed. |
| 103 | S&F M.S. frame work such as grills, gratings, angle frame etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, cooler stands and similar work conforming to Fe.290.Gde-E-165 aoat of red oxide primerafter preparation of steel surfaces complete all as specified & directed. |
| 104 | Preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed. |
| 105 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in soft/loose soil complete all as specified & directed. |
| 106 | M&L for PCC Type D2 1:4:8 (40 mm graded stone aggregate)Cement concrete in foundations, filling and mass-concrete complete all as specified & directed. |
| 107 | M&L for PCC 1:2:4 type B1 using 20mm graded stone aggragate as in bed blocks, coping etc including weathering slightly rounded or chamfered angles and throating making grovves for fixing of man hole cover including necessary form work complete all as specified & directed. |
| 108 | Returning filling in incl spreading levelling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified & directed. |
| 109 | Removal of excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above or below the starting point complete all as specified & directed. |
| 110 | Removing ofdemolition materials beyond 500 m and upto total distance of 1.5 km and depositing where directed at a level n exc. 1.5 m above the starting point |
| 111 | M&L Concrete bed to drain pipes 150mm dia including packing under, and haunching against the sides of pipes after they are laid and tested; in PCC(1:4:8) type D2 (using 40 mm graded stone aggregate) complete all as specified and directed. |
| 112 | M&L 150 mm Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed |
| 113 | M&L PCC(1:3:6) type C1 (using 20mm graded stone aggregates) in benching to manhole complete all as specified and directed. |
| 114 | M & L for precast RCC 1:2:4 type B-1(using 20mm graded stone aggregate) for manhole/drain cover including placing and set in CM 1:4 all as specified |
| 115 | M & L mild steel (TMT bar)10mm dia and over cut to length bent to shape reqd, incl, cranking benching spirally for copying for columns hooking ends and bending with and including MS wire annealed wire not less than 0.9 mm dia. |
| 116 | Demolition of cement/lime concrete (un-reinforced) in ground floor and paving exc. 15 cm thickness(below or above ground level.) & removal of rubbish material complete all as specified& directed. |
| 117 | Dismanltingof kerb stoneincluding cement bedding & removed off rubblecomplete all as specified & directed. |
| 118 | M&Lfor 75 mm thick PCC 1:4:8 type D -2 using 40 mm graded aggregate as in sub base of path/hardstanding complete all as specified & directed. |
| 119 | M&L 60mm thick machine pressed precast conctete coloured interlocking paver block with grey cement andpigment any shape and size confirming to IS 15658-2006 , M-35 Grade and over 25mm thick sandcomplete all as specified and as directed. |
| 120 | M&LPrecast cement concrete solid blockfactory made in PCC 1:2:4 type B-1 using (20 mm graded stone aggregates) set in CM 1:6(sizeof precast concrete block complete all as specified & directed. |
| 121 | Demolition of RCC (water tank) of any description and in any position not otherwise specifically provided foris reinforced (reinforcement cut as required to facilitate demolition) complete all as specified & directed. |
| 122 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified & directed. |
| 123 | Taking down UnserviceableDB TPN/SPN any type any capacity complete and making good to disturbed surfaces of wall complete all as specified & directed. |
| 124 | M&L for point wiring for One light/fan point controlled by one switch, 1100 Volts grade 1.5 Sqmm PVC insulated FRLS unsheathed cable with multistrandedcopper conductor conforming to IS:694:1990 with ISI marking in and including concealed PVC conduit of suitable size with all accessoriesin wall/ceiling /floor/roofetc, sunk pressed steel or cast iron terminal boxes with 3mm thick plastic laminated sheet top cover including 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor conforming to IS:694:1990 with ISI marking as continuous earthwire connected to common earth dolly all as specified and directed |
| 125 | All as per srl item No 124.00 but for One 3 pin 5 amp socket outlet on independent board |
| 126 | All as per srl item No 124.00 but for one three pin socket outlet 5 amps on the same board |
| 127 | All as per srl item No 124.00 but for One bell/buzzer point controlled by one push button independent |
| 128 | M&L for point wiring complete for one socket outlet 15 amps on an independent board with FRLS, PVC insulated and unsheathed cable 2.5 Sqmm (nominal area) multi stranded copper conductor single core conforming to IS: 694 including concealed PVC conduit of suitable size, pressed steelterminal boxes not less than 2 mm thick of required size (factory made) includingpainting terminal boxes inside and outside with two coats of synthetic enamel paint over a coat of red oxide primer and with top cover 3mm thick of plastic laminated sheets of required colour, complete with all accessories and all as specified including FRLS PVC insulated and unsheathed cable 2.5 Sqmm (nominal area) multi stranded copper conductor single core conforming to IS: 694 of green colour as earth wire to common earth and connected to earth dolly drawn in same concealed conduit complete and controlled by one 15 Amp switch complete all as specified and directed. |
| 129 | M&L for point wiring complete for one socket outlet 15 amps on an independent board with FRLS, PVC insulated and unsheathed cable 4 Sqmm (nominal area) multi stranded copper conductor single core conforming to IS: 694 including concealed PVC conduit of suitable size pressed steelterminal boxes not less than 2 mm thick of required size (factory made) includingpainting terminal boxes inside and outside with two coats of synthetic enamel paint over a coat of red oxide primer and with top cover 3mm thick of plastic laminated sheets of required colour, complete with all accessories and all as specified including FRLS PVC insulated and unsheathed cable 4 Sqmm (nominal area) multi stranded copper conductor single core conforming to IS: 694 of green colour as earth wire to common earth and connected to earth dolly drawn in same concealed conduit complete and controlled by one 15 Amp switch complete all as specified and directed. |
| 130 | Supply and fixceiling fan regulator electronic step type 230 Volts single phase all as specified and directed. |
| 131 | Taking down submain wiring cable any number of runs alongwith earth wire from the existing concealed or surface conduit and offering credit as per schedule of credit all as directed.Note : Any runs of cable and earthwire will be measured as one unit length. |
| 132 | M&L for submain wiring with 4 run of 6 sqmm single core copper conductor PVC insulated cable and 1 run of 6 sqmm single core copper conductor insulated cable as earthing lead drawn throughPVC conduit all as directed. Note:4 run of 6 sqmm cable and 1 run of 6 sqmm cable together will be measured as one unit length. |
| 133 | Supply and fixin repair switch Piano 6 Amps one way flush type,make, ISI marked,all as specified and directed. |
| 134 | Supply and fixin repair Bell push, flush type, 5 amp ISI marked,all as specified and directed. |
| 135 | Supply and fix switchsocket combination outlet 3 pin 6/16 Amps flush type multipurpose with fuse & neon indicator make ISI marked,all as specified and directed. |
| 136 | Supply & Fix ceiling rose surface bakelite 65 x 50 mm three terminal, all as specified and directed. |
| 137 | Supply & fix Inverter rechargeable LED batten tube light along with fixture, 3feet long, 1x20 W AC ,Energy saving, back up up to 4 hrs, power ful lithium battery-5600 mah, long battery life-500+ rechage cycle charging time 8-10 hrsincluding LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make : Halonix, Havells, philips, wipro or equivalent |
| 138 | Supply & fix in repairsLED 10 wattB 22 inverter rechargeable LED T-bulb complete all as specified and directed Make: Philips, Halonix, Havells, wipro or equivalent |
| 139 | Supply and fixbatten Holder PVC/polycarbonate type with cord grip cap suitable for pendent fittings ISI marked,all as specified and directed. |
| 140 | M&L for rewinding ceiling fan 1200/1400mm sweep with super enamalled copper wire of exisiting gauge including insulation material varnishing and drying all as directed. |
| 141 | S&F in repairs MCB DB TPN 8 Way double door 415 Volts all as specified and directed. |
| 142 | S&F in repairs MCB DB SPN 8 Way double door 240 Volts with 200 amps rated bus bar all as specified and directed. |
| 143 | Supply & fix in repairs MCB TPN 63 amp, 230 Volts, Single phase, 10 KA Capacity all as specified and directed. |
| 144 | Supply & fix in repairs MCB SPN 40 Amp, 230 Volts, Single phase, 10 KA Capacity all as specified and directed. |
| 145 | Supply & fix in repairs MCB SP, 6 to 40 Amps, 230 Volts, Single phase, 10 KA Capacity all as specified and directed. |
| 146 | S&F in repairs bell, multi music type AC, 230 volts singlepole |
| 147 | M&L for earthing complete with galvanized steel earth plate 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe light grade 15 mm bore for protection of GI wire from earth electrode to and including the earth test point of galvanized Iron/steel of size 75 x 75 x 25 mm,supplying and laying charcoal dust, common salt, PCC 1:2:4 typeB-1 chamber and MS angle iron frame 40 x 40 x 3 mm and RCC cover 40 mm thick (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, GI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified & directed. |
| 148 | Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 50 sqmm3.5 core laid in trenches/ ducts, through pipe, under floors or roads/ along poles etc complete all as specified. Note :- Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. |
| 149 | M&L for brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection including taking down old unserviceable bricks complete all as specified & directed. |
| 150 | M&L for dry sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required covercomplete all as specified and directed.Note :- Thickness after punning shall be considered for payment. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy