| Sl. No. | Item Description |
| 1 | Material & Labour for replacement of old Unserviceable compressor with new hermitically sealed unit compressor, suitable forwindow AC of capacity 1.5 TR, 240V, 50 Hz,including first fill of refrigerant gas (R-32, R-410, R-134, R-600, R-134A, R-410A), brazing jointing, leak proof testing & commissioning Complete all as specified and directed.Note: Rate quoted by contractor deemed to be inclusive of replacement warranty of 5 Yrs for compressor.Note: Necessary warranty certificate to be submitted by contractor |
| 2 | Material & Labour for replacement of old Unserviceable compressor with new hermitically sealed unit compressor, suitable forwindow AC of capacity 2.0 TR including first fill of refrigerant gas, brazing jointing (R-32, R-410, R-134, R-600, R-134A, R-410A), leak proof testing & commissioning complete all as specified and directed.Note: Rate quoted by contractor deemed to be inclusive of replacement warranty of 5 Yrs for compressor.Note: Necessary warranty certificate to be submitted by contractor |
| 3 | Material & Labour for replacement of old Unserviceable compressor with new hermitically sealed unit compressor, suitable for Split AC of capacity 1.5 TR including first fill of refrigerant gas (R-32, R-410, R-134, R-600, R-134A, R-410A), brazing jointing, leak proof testing & commissioning complete all as specified and directed.Note: Rate quoted by contractor deemed to be inclusive of replacement warranty of 5 Yrs for compressor.Note: Necessary warranty certificate to be submitted by contractor |
| 4 | Material & Labour for replacement of old Unserviceable compressor with new hermitically sealed unit compressor, suitable for Split AC of capacity 2.0 TR including first fill of refrigerant gas (R-32, R-410, R-134, R-600, R-134A, R-410A), brazing jointing, leak proof testing & commissioning complete all as specified and directed.Note: Rate quoted by contractor deemed to be inclusive of replacement warranty of 5 Yrs for compressor.Note: Necessary warranty certificate to be submitted by contractor |
| 5 | Material & Labour for replacement of old Unserviceable compressor with new hermitically sealed unit compressor, suitable for Split AC (Inverter type ) of capacity 1.5 TR including first fill of refrigerant gas (R-32, R-410, R-134, R-600, R-134A, R-410A), brazing jointing, leak proof testing & commissioning complete all as specified and directed.Note : Rate quoted by contractor deemed to be inclusive of replacement warranty of 5 Yrs for compressor.Note: Necessary warranty certificate to be submitted by contractor |
| 6 | Material & Labour for replacement of old Unserviceable compressor with new hermitically sealed unit compressor, suitable for water coolerof capacity 40/80 Ltr including first fill of refrigerant gas (R-32, R-410, R-134, R-600, R-134A, R-410A), brazing jointing, leak proof testing & commissioning complete all as specified and directed.Note : Rate quoted by contractor deemed to be inclusive of replacement warranty of 5 Yrs for compressor.Note: Necessary warranty certificate to be submitted by contractor |
| 7 | Material & Labour for replacement of old Unserviceable compressor with new hermitically sealed unit compressor, suitable for water coolerof capacity 60/120 Ltr including first fill of refrigerant gas (R-32, R-410, R-134, R-600, R-134A, R-410A), brazing jointing, leak proof testing & commissioning complete all as specified and directed.Note : Rate quoted by contractor deemed to be inclusive of replacement warranty of 5 Yrs for compressor.Note: Necessary warranty certificate to be submitted by contractor |
| 8 | Material & Labour for replacement of old Unserviceable compressor with new hermitically sealed unit compressor, suitable for Refrigerator of capacity 80 ltr to 210 ltr including first fill of refrigerant gas (R-32, R-410, R-134, R-600, R-134A, R-410A), brazing jointing, leak proof testing & commissioning complete all as specified and directed.Note : Rate quoted by contractor deemed to be inclusive of replacement warranty of 5 Yrs for compressor.Note: Necessary warranty certificate to be submitted by contractor |
| 9 | Material & Labour for replacement of old Unserviceable compressor with new hermitically sealed unit compressor, suitable for Refrigerator of capacity 220 ltr to 320 ltr including first fill of refrigerant gas (R-32, R-410, R-134, R-600, R-134A, R-410A), brazing jointing, leak proof testing & commissioning complete all as specified and directed.Note : Rate quoted by contractor deemed to be inclusive of replacement warranty of 5 Yrs for compressor.Note: Necessary warranty certificate to be submitted by contractor |
| 10 | Material & Labour for replacement of old Unserviceable compressor with new hermitically sealed unit compressor, suitable for Deep freezer of capacity 400-450 ltr including first fill of refrigerant gas (R-32, R-410, R-134, R-600, R-134A, R-410A), brazing jointing, leak proof testing & commissioning complete all as specified and directed.Note : Rate quoted by contractor deemed to be inclusive of replacement warranty of 5 Yrs for compressor.Note: Necessary warranty certificate to be submitted by contractor |
| 11 | M&L for taking downAir-Conditioner Window Type of any capacity and make from its existinglocation by disconnecting electrical lines for maintenance/servicing/ overhaulingand dismantling the same for repair/ replacement of unserviceable parts, servicing of Air conditioning of any capacity including air Filter Cleaning, Condenser and Evaporator coil Cleaning, insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water complete all as specified and directed and refixing the same in its original location /position , connecting all electrical connection and testing complete all as specified and directed.Note : (a)New parts shall be measured and paid separately under \"Supply only\" rates here-in-after. (b) Minor Parts/ petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department .(c).Spare parts alongwith Refrigerant gas shall be measured and paid separately under respective item of the schedule. |
| 12 | M&L for taking downAir-Conditioner Split type (both indoor & Outdoor ) of any capacity and make from its existinglocation by disconnecting electrical lines for maintenance/servicing/ overhaulingand dismantling the same for repair/ replacement of unserviceable parts, servicing of Air conditioning of any capacity including air Filter Cleaning, Condenser and Evaporator coil Cleaning, insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water complete all as specified and directed and refixing the same in its original location /position , connecting all electrical connection and testing complete all as specified and directed.Note : (a)New parts shall be measured and paid separately under \"Supply only\" rates here-in-after. (b) Minor Parts/ petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department .(c).Spare parts alongwith Refrigerant gas shall be measured and paid separately under respective item of the schedule. |
| 13 | M&L for taking downparts ofwater cooler of any capacity and make from its existinglocation by disconnecting and sealing all electrical lines for maintenance/servicing/ overhaulingand dismantling the same for repair/ replacement of unserviceable parts,cleaning , taking out sludge from inner parts and washing wih cleaning solution and reassembling and refixing the same in its original location /position , connecting all electricalconnection and testing complete all as specified and directed.Note : (a)New parts shall be measured and paid separately under \"Supply only\" rates here-in-after.(b) Minor Partif any , not mentioned in the schedule but required for smooth functionng of Refrigerator are deemed to be included in the unit rate of the item. |
| 14 | M&L for Taking downparts of Refrigerator of any capacity and make from its existinglocation by disconnecting and sealing all electrical lines for maintenance/servicing/ overhaulingand dismantling the same for repair/ replacement of unserviceable parts,cleaning , taking out sludge from inner parts and washing wih cleaning solution and reassembling and refixing the same in its original location /position , connecting all electricalconnection and testing complete all as specified and directed by Engineer-in-charge.Note : (a)New parts shall be measured and paid separately under \"Supply only\" rates here-in-after.(b) Minor Partif any , not mentioned in the schedule but required for smooth functionng of Refrigerator are deemed to be included in the unit rate of the item. |
| 15 | M&L forTaking downparts of Deep freezer of any capacity and make from its existinglocation by disconnecting and sealing all electrical lines for maintenance/servicing/ overhaulingand dismantling the same for repair/ replacement of unserviceable parts,cleaning , taking out sludge from inner parts and washing wih cleaning solution and reassembling and refixing the same in its original location /position , connecting all electricalconnection and testingcomplete all as specified and directed.Note : (a)New parts shall be measured and paid separately under \"Supply only\" rates here-in-after.(b) Minor Partif any , not mentioned in the schedule but required for smooth functionng of Refrigerator are deemed to be included in the unit rate of the item. |
| 16 | Supply onlyfollowing items to be fixed under Ser Item No. 1.00 to 5.00 for Window/ Split type AC complete all as specified and directed:- |
| 17 | Starting capacitor of capacity 100/120 MFD, 50 Hz, 370 or 440 V. |
| 18 | Starting capacitor of capacity 80/100 MFD, 50 Hz, 370 or 440 V. |
| 19 | Starting capacitor of capacity 60/80 MFD, 50 Hz, 370 or 440 V. |
| 20 | Remote1.5 / 2.Ton Capacity AC any type. |
| 21 | Blower motor(Hot & Cold type)suitable for 1.5/2.0 Split type AC. |
| 22 | Swing motor suitable for 1.5 Ton Capacity Split type Air Conditioner. |
| 23 | Air Filter Suitable for1.5/2.Ton Capacity Split type Air conditioner. |
| 24 | Condenser motor with fan blade suitable for 1.5 Ton capacity Split type AC. |
| 25 | Indoor unit fan motor with blade. |
| 26 | New PCB (printed circuit board ) units as per existing model/make for non inverter type split AC 1.5/2 Ton capacity complete all as specified and directed. Make:Blue star/Voltas/LG/Samsung |
| 27 | New PCB (printed circuit board ) units as per existing model/make for inverter type ( both indoor & outdoor unit PCB)split AC 1.5/2 Ton capacity complete all as specified and directed. Make:Blue star/Voltas/LG/Samsung |
| 28 | Copper tubing of size 1/2\" &1/4\" along with sleeve insulation complete. |
| 29 | Suction valve/Liquid valve of size 1/2\" & 1/4\" along with dead nut, flare nutcomplete suitable for split AC cap 1.5/2 Ton out door unit complete. |
| 30 | M&L for Repair of PCB any typeunits as per existing model/make for non inverter type split AC 1.5/2 Ton capacity complete all as specified and directed |
| 31 | Supply only of following items to be fixed under Ser Item No. 6.00 & 7.00 Water Cooler complete all as specified and directed: |
| 32 | Motor with fan blade suitable for Water Cooler. |
| 33 | Chromium plated Push typeTap of 15 mm suitable for water Cooler. |
| 34 | Thermostate Suitable for water cooler. |
| 35 | Over load protector for water cooler. |
| 36 | Stainless steel tank suitable for water cooler. |
| 37 | PVC connection pipe Suitable for Water Cooler. |
| 38 | Supply only of following items to be fixed under Sr Item No. 8.00 & 9.00 Refrigerator complete all as specified and directed. |
| 39 | Magnetic door gasket suitable for 165to200 ltrs capacity Refrigerator. |
| 40 | Magnetic door gasket suitable for 255 to310 ltrs capacity Refrigerator. |
| 41 | Freezer / Evaporator suitable for165 to 200 ltrs capacity Refrigerator. |
| 42 | Freezer/ Evaporator suitable for255 to 320 ltrs capacity Refrigerator. |
| 43 | Thermostat switch to match with the existing item suitable for refrigerator of any capacity. |
| 44 | Over load protector suitable for refrigerator to match with the existing design. |
| 45 | Air Filter suitable for for any make and any capacity Refrigerator. |
| 46 | Capillary tube of suitable length as per existing size for refrigerator any make and any capacity. |
| 47 | Vegetable tray as per sample and suitable for refrigertator any type and any make. |
| 48 | PVC Stand for Refigerator capacity any make and any capacity as per sample. |
| 49 | Supply only of following items to be fixed under Ser Item No. 10.00 Deep Freezer complete all as specified and directed. |
| 50 | Motor with fan blade suitable for Deep freezer. |
| 51 | Thermostate Suitable for deep freezer. |
| 52 | Material & Labour for Rewinding of fan motor of Water Cooler, Desert cooler,split and window type AC of any size with super enameled copper winding wire of existing gauge including insulation, warnishing etc, and replacement of worn out bushes, bearings, shafts, nuts, bolts and washers includind greasing, oiling, reassembling and testing the motor complete all as specified and directed :- |
| 53 | 1/10 HP and 1/35 HP Suitable for water cooler. |
| 54 | 1/7 HP Suitable for Desert cooler. |
| 55 | 1/4 HP and 1/6 HP Suitable for AC any type. |
| 56 | M&L for servicing, cleaningof desert cooler of any make, capacity, type by blower, cleaning honey comb/ Khas pad, replacement of damaged nut & bolts, connecting water pump connection, selector knobs, burnt wiring , tighting, checking of electrical connections etc. complete up to satisfaction of Engr in charge complete all as specified and directed. Note: New parts shall be measured and paid separately. |
| 57 | Supply only of following items to be fixed under Ser Item No. 22.00 desert Cooler complete all as specified and directed. |
| 58 | Water lifting pump suitable for Desert cooler of 1/20 Hp, 240 volts, 50 Hz, 12 watts, 1.5 mtr head capacity complete all as specified and directed.Make:Crompton /Khaitan/Kenstar |
| 59 | PVC switch box including two switch & indicater of Plaza Make forDesert cooler complete all as specified and directed. |
| 60 | Newspeed control regulator for Desert cooler 240 volts 50 Hz, single phase, complete any make and any size. Make : PLAZA/KINJAL/ANCHOR |
| 61 | Desert cooler water tank suitable for Desertcooler (as per existing size) made out of 22 gauge GI sheet made to shape including complete all as specified and directed . |
| 62 | Wood woolpads / Honeycomb type of required size for Desert cooler any make including complete all as specified and directed . |
| 63 | Front Grill made out of 22 gauge GI sheet suitable for Desert cooler any make/size complete all as specified and directed . |
| 64 | Fan motor, single phase, 230 volt ,50 Hz ,1/7 HP with blade arm 18\" sweep size suitable for Desert cooler, complete all as specified and directed. Make: Khaitan/Champion/Jyoti |
| 65 | Capacitor 4MFD ,230 volt ,50 Hzsuitable for Desert cooler, complete all as specified and directed. |
| 66 | M&L for Repair/replacement of damaged body of Desert cooler, with 1 mm thick MS sheet any make complete all as specified and directed . |
| 67 | S&F in Replacement of defective / damaged transformer of voltage stabilizer complete all as specified and directed of following capacity:- |
| 68 | (a)5 KVA |
| 69 | (b)4 KVA |
| 70 | Re-filling of Refrigerent gas Non CFC R 32 of Window AC & Split AC of capacity 1.5 Tr including breezing, jointing, leak testing, commissioning, taking down and refixing complete all as specified and directed . |
| 71 | Re-filling of Refrigerent gas Non CFC R-410A/R-32 of Window AC & Split AC of capacity 1.5 Tr including breezing, jointing, leak testing, commissioning, taking down and refixing complete all as specified and directed . |
| 72 | Re-filling of Refrigerant gas Non CFC (R-134 A) of Refregirator, water Cooler and Deep Freezer of any capacity including brazing, jointing, leak testing, commissioning, taking down and refixing complete all as specified and directed . |
| 73 | M&L for Preparation of surfaces and applying two coat of synthetic enamel spray painting on metal surface (inner/outer) including writingSM No/MES No with paint todesert cooler of any make and size complete all as specified and directed . |
| 74 | M&L for Preparation of surfaces and applying two coat of synthetic enamel spray painting on metal surface (inner/outer) including writingSM No/MES No with paint to water cooler of any make and size complete all as specified and directed . |
| 75 | M&L for Preparation of surfaces and applying two coat of synthetic enamel spray painting on metal surface (inner/outer) including writingSM No/MES No with paint to split/window ACof any make and size complete all as specified and directed . |
| 76 | M&L for Core Cutting to make provisional holes for purpose of electric wiring / drain pipe outlet / fixing of AC any type / any size or drain pipeincluding surface finishing complete all as specified and directed. |
| 77 | S&F in replacementswitch socket combination flush type 5 Ampscomplete all as specified and directed. Make : PLAZA/KINJAL/ANCHOR |
| 78 | S&F in repair single pole and neutral encloser with two pin and earth plug and socket complete with one MCB SP 32/20 Amps complete all as specified and directed.Make: L & T/Legrarnd/Schinder. |
| 79 | S&F in repairs MCB SP, 230 volts, 20 to 32 amps complete all as specified and directed. |
| 80 | S&F in repairs MCB SPN, 230 volts, 32 to 40 amps complete all as specified and directed. |
| 81 | S&F in repairs Three core copper flexible wirePVC insulated cable andPVC sheathed of size 40/0.076 mm complete all as specified and directed. |
| 82 | S&F in repairsthree pin plug top 15 Amps ISI mark complete all as specified and directed. Make : PLAZA/KINJAL/ANCHOR |
| 83 | S&F in repairs switch socket combination 15 Amp flush type, 240 Volts, 50 Hz complete all as specified and directed. |
| 84 | S&F in replacement of PVC drain pipe of 15mm dia and 0.5mm thick corrugated type complete all as specified and directed. |
| 85 | S&F replacement to unsv heating element of capacity 3 KW suitable forsolar water heater system of capacity 200/500LPD complete all as specified and directed. |
| 86 | S&F replacement to unsv thermostate suitable for solar water heater system of capacity 200/500LPD complete all as specified and directed. |
| 87 | M&L for painting of steel surface of solar water heater system metallic surface frames etc. with two coats of zinc cromite red oxide priner followed by two coats of enamel paint of suitable colour after preperation of old surface and making good complete all as specified and directed. |
| 88 | S&F replacement to hose pipe for solar pannel to hot water tank as per exisiting length and dia suitable for solar heating system of capacity 200/500lpd by clamping/tightening properly for tank leak proof joint complete all as specified and directed. |
| 89 | S&F in repair of electric water heater storage type of capacity 25 Ltrs, vertical type, 5 star rated with 2/3 KW heating element and grouting including suitable size of nuts and bolts fixing in the wall with PCC 1:2:4 type B1, using 20 mm graded stone aggregate and making good to disturbed surfaces. PVC connection 15 mm size with PTMT nuts of length 400 mm as inlet for cold water and PVC connection of 15 mm size, spirally reinforced with stainless steel wire inside the pipefor outlet hot water pipe connection with brass nuts at both ends of length 450 mm including necessary electric and water connection complete all as specified and directed. Make - Bajaj/Havells/CG.Note: Old u/s parts to be deposited by contractor to MES store yard at his own arrangements. |
| 90 | M&L cross arms, bracings, supports, clamps and back plates fabicated from structural steel sections including nuts, bolts, washer, welding, bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed including of one primer coat under coat and one finising coat of paint for solar water heater complete all as specified and directed. |
| 91 | Maintenance and repair of solar water heahting system (plant) of capacity 200 LPD, cleaning, servicing of complete system including panel and solar water tube, cleaning of air blockage and minor repair with replacement of parts as requireed at site complete all as specified and directed. |
| 92 | S&F in repair heating element of capacity 1.5/2 KW suitable for 25 Ltr geyser requireed at site complete all as specified and directed. |
| 93 | S&F in repair thermostatsuitable for 25 Ltr geyser requireed at site complete all as specified and directed. |
| 94 | Taking down geyser of capacity 25 Ltrfrom existing position by removing all electric connections and refixing the sameincluding paintingof geyser after removing old paint by two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 95 | S&F Geyser connection pipe 12\"/18\"\" long with sockets in both end, made of steelcomplete all as specified and directed. |
| 96 | Taking down carefully any type of old unserviceable point wiring copper or aluminium conductor (light, fan, socket, bell or power) point complete with fittings such as switches ceiling roses, lamp holders, sockets, fan regulators, call bell, light fittings with PVC conduit surface / concealed or wooden battens including sunken cast iron / pressed steel terminal boxes etc and making good the disturbed surfaces of walls, roof, floors etc to match with the existing surfaces complete all as specified & directed. |
| 97 | Taking down carefully any type of old unserviceable submain wiring with PVC conduit surface / concealed or wooden battensetc and making good the disturbed surfaces to match with the existing surface complete all as specified & directed. |
| 98 | M&L of Sub main wiring with two single core PVC Insulated cable two run of size 4 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 20 mm dia with all conduit accessories and one run of 4.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire including making good disturbed surface to match existing complete all as specified & directed.Note : - Two run of 4 Sqmm & one run of 4.0 Sqmm cable shall be measured as one unit run. |
| 99 | M&L ofSub main wiring with two single core PVC Insulated cable two run of size 6.0 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 6.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire complete all as specified and directed. Note : - Two run of 6 Sqmm & one run of 6 Sqmm cable shall be measured as one unit run. |
| 100 | M&L for point wiring with three layer PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLSH cable 1100 Volts grade drawn intoand concealed PVC conduits medium grade not less than 20mm( ISI marked) including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes/Modular metal flush box duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick hylam brand laminated white bakelite sheet cover for mounting switches, sockets, fan regulators fixed with CP screws with cup wahsers and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 to match with the existing surfaces complete all as specified & directed for One light Point controlled by one switch. |
| 101 | ~ditto~ all as per item No. 56.00 above but for oneFanPoint controlled by one switch complete all as specified & directed. |
| 102 | ~ditto~ all as per item No. 56.00 above but for oneBell Point controlled by one switch complete all as specified & directed. |
| 103 | ~ditto~ all as per item No. 56.00 abovebut for one socket point 5 Amp controlled by one switch on same board complete all as specified & directed. |
| 104 | ~ditto~ all as per item No. 56.00 above but for onesocket point 5 Amp controlled by one switch on Independent board complete all as specified & directed. |
| 105 | ~ditto~ all as per item No. 56.00 above but for onelight point controlled by two way switch complete all as specified & directed. |
| 106 | ~ditto~ all as per item No. 56.00 above but with 1100 Volts grade copper stranded conductor FRLSH cable of size 2.5 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified & directed. |
| 107 | M&L for drawingthe wire in with casing capingcomplete with point wiring withFRLSHPVC insulated, unsheathed stranded copper conductor of nominal area 1.5 Sqmm, 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wireto common earth dolly in andsunkenterminal boxes pressed MS/GI steel terminal boxes not less than 1.20 mm thick for mounting switch, socket etc including 3 mm thick Hylam brand sunmicalaminated sheet coveror inner outer plates for modular switches with brass screw and cup washers with all accessories and making good to disturbed surface with cement mortar ratio of 1:3 and matching surface with existing white/colour wash, oil bound or cement base paint etc to match with existing surface complete all as specified & directed for one light/ Fan / Bell Point controlled by one switch. |
| 108 | ~ditto~ all as per item No. 63.00 above but for one socket point 5 Amp controlled by one switch on same board complete all as specified & directed. |
| 109 | ~ditto~ all as per item No. 63.00 above but for onesocket point 5 Amp controlled by one switch on Independent board complete all as specified & directed. |
| 110 | ~ditto~ all as per item No. 63.00 above but for onelight point controlled by two way switch complete all as specified & directed. |
| 111 | ~ditto~ all as per item No. 63.00 above but drawing in with casing capingpoint wiring using 2.5 Sqmm (Nominal area)triple layerFRLSHPVC insulated unsheathed copperconductor 1100 volts for one 3/6 pin socket outlet ,suitable for 6/16 amps on “independent board”.with 2.5 sqmm with one single run copper wire as continuous earth wireto common earth dollycomplete all as specified & directed. |
| 112 | M&L for point wiring with three layer PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLSH cable 1100 Volts grade drawn into the existing conduits including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick hylam brand laminated white bakelite sheet cover for mounting switches, sockets, fan regulators fixed with CP screws with cup wahsers and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 to match with the existing surfaces complete all as specified & directed for one light Point controlled by one switch. |
| 113 | ~ditto~ all as per item No. 68.00 above but for oneFanPoint controlled by one switch complete all as specified & directed. |
| 114 | ~ditto~ all as per item No. 68.00 above but for oneBell Point controlled by one switch complete all as specified & directed. |
| 115 | ~ditto~ all as per item No. 68.00 above but for one socket point 5 Amp controlled by one switch on same board complete all as specified & directed. |
| 116 | ~ditto~ all as per item No. 68.00 above but for onesocket point 5 Amp controlled by one switch on Independent board complete all as specified & directed. |
| 117 | ~ditto~ all as per item No. 68.00 above but for onelight point controlled by two way switch complete all as specified & directed. |
| 118 | ~ditto~ all as per item No. 68.00 above but with 1100 Volts grade copper stranded conductor FRLSH cable of size 2.5 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified & directed. |
| 119 | S&Fcall bell ding dong sound type suitable for AC 230 volt single pole complete all as specified & directed. |
| 120 | S&F switch bell push flush type suitable for 5 Amp 230 Volt of polycarbonate body complete all as specified & directed. |
| 121 | S&F switch piano flush type suitable for 5 Amp 230 Volt of polycarbonate body complete all as specified & directed. |
| 122 | S&F socket outlet 2 in 1, 5 Pin 5 Amp flush type of polycarbonate body complete all as specified & directed. |
| 123 | S&F Ceiling rose surface type 60x30 mm three terminals of polycarbonate body complete all as specified & directed. |
| 124 | S&F Ceiling Fan regulator electronic type 280 Watt capacity of polycarbonate body ISI marked complete all as specified & directed. |
| 125 | S&F in replacement of frame plate for modular switch 1 module includingscrews and washers etc model/make as per existingin site complete all as specified and as directed. |
| 126 | S&F in replacement of frame plate for modular switch 2 module includingscrews and washers etc model/make as per existingin site complete all as specified and as directed. |
| 127 | S&F in replacement of frame plate for modular switch 3 module includingscrews and washers etc model/make as per existingin site complete all as specified and as directed. |
| 128 | S&F in replacement of frame plate for modular switch 4 module includingscrews and washers etc model/make as per existingin site complete all as specified and as directed. |
| 129 | S&F in replacement of frame plate for modular switch 6 module includingscrews and washers etc model/make as per existingin site complete all as specified and as directed. |
| 130 | S&F in replacement of frame plate for modular switch 8 module includingscrews and washers etc model/make as per existingin site complete all as specified and as directed. |
| 131 | S&F in replacementMS Housing box 1/2 module suitable formodular switch as per existingswitch boxand making good to the disturb surfacecomplete all as specified and as directed. |
| 132 | S&F in replacementMS Housing box 3 module suitable formodular switch as per existingswitch boxand making good to the disturb surfacecomplete all as specified and as directed. |
| 133 | S&F in replacementMS Housing box 4/5 module suitable formodular switch as per existingswitch boxand making good to the disturb surfacecomplete all as specified and as directed. |
| 134 | S&F in replacementMS Housing box 6/8 module suitable formodular switch as per existingswitch boxand making good to the disturb surfacecomplete all as specified and as directed. |
| 135 | S&F in replacement of modular switch6-10Amps one module230 volts AC as per existing model/make complete all as specified and as directed |
| 136 | S&F in replacement of modular switch16 Amps one module230 volts AC as per existing model/make complete all as specified and as directed |
| 137 | S&F in replacement of modular socket, 6A -2/3 pin combined 2 module,230 volts AC as per existing model/make complete all as specified and as directed. |
| 138 | S&F in replacement of modular socket, 6/16A -2/3 pin combined 2 module,230 volts AC as per existing model/make complete all as specified and as directed . |
| 139 | S&F in replacement modular fan regulator, 2 Module 4 step 180w heavy duty 230 volts as per existing model/make complete all as specified and as directed. |
| 140 | S&F in replacement of 3mm thick hylam sheet of any sizeincluding brass screws and washers etc as per required at site complete all as specified and as directed. |
| 141 | S&F in replacement modular bell push switch piano, flush type, 6 Amps complete all as specified and as directed. |
| 142 | S&F in replacementswitch piano type switch two way AC 230 volts6 Ampsas per on existing switch board complete all as specified & directed. |
| 143 | S&F rigid non metallic, medium grade, PVC conduit, concealed type of size25 mm with all accessories such as couplers, lock nuts, saddles, pipe hook, tees, bends, etc., including cutting chases for conduits and making good the disturbed surface with PCC as per site requirement complete all as specified & directed. |
| 144 | S&F rigid non metallic, medium grade, PVC conduit, concealed type of size 32 mm with all accessories such as couplers, lock nuts, saddles, pipe hook, tees, bends, etc., including cutting chases for conduits and making good the disturbed surface with PCC as per site requirement complete all as specified & directed. |
| 145 | S&F in replacement of single corewire 4 Sqmm multi-strand PVC insulated copper conductor FRLS cable(red,yellow,blue & black) including connections of cable with MCBs or bus bars complete all as specified and directed. Make:- Anchor/Havells/ polycab/ plaza |
| 146 | S&F in replacement of single corewire 2.5 Sqmm multi-strand PVC insulated copper conductor FRLS cable (red,yellow,blue & black)including connections of cable with MCBs or bus bars complete all as specified and directed. Make :- Anchor/Havells/ polycab/ plaza |
| 147 | S&F in replacement of single corewire 1.5 Sqmm multi-strand PVC insulated copper conductor FRLS cable(red,yellow,blue & black) including connections of cable with MCBs or bus bars complete all as specified and directed. Make :- Anchor/Havells/ polycab/ plaza |
| 148 | S&F in replacement MCB Single Pole and Neutral 240Volt, 40 Amps, \"C\"series,10KA breaking capacity complete all as specified & directed. Make:Legrand cat no :4086 18 or eq in SEIMENS /GE |
| 149 | S&Fin repair RCBOs For earth Leakage , overload & short Circuit Protection Double Pole 30 mA complete all as specified and directed |
| 150 | S&F in repair single pole and netural sheet metal enclosure with a two pin and earth plug and socket complete with 01 number single pole MCB 20 Amps complete all as specified & directed. Make: Legrand cat no :5078 11 or eq in SEIMENS /GE |
| 151 | S&F in repair Smart bright Batten Series, LED luminaire using LEDs 22 watt, natural white, 2200 Lumen, THD max 10 % ,CRI min 80 % with diffuser which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light output with wide voltage protection range, stable color start Extruded Aluminum housing, Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall and ceiling mounting using brackets (supplied along with The Luminaire has been tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Secl), report has established conformity of the product(s) to the requirements of the Standard/Specification complete all as specified & directed.Make : Philips Cat part BN 021 LED 22S4000 PSU GR SI ,crompton or Philips |
| 152 | S&F repair mirror light 12 watts surface/wallmounted fittingwith all accessaries durale and ecofriendly and proper connection from fitting to existing point as per site requirement and making the surface smooth complete all as specified & directed. |
| 153 | S&F in replacement ofLED Security Light Luminaire 25 wattwith 2500 or more lumen warm white, surge protection device upto 4KV, IP65/66 or more, IK07 or more, potted driver suitable for 180 to 270 V, 50 Hz, light engine driver base.pole adapter, powder coated pressure die cast aluminium with heat resistant toughened glass with lens type,GI pipe 25 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos ofpole fitting clamps made out of MS flat , nutsand boltsand painting with aluminium paint. complete all as specified and as directed. Make: Philipscat part no: BRP029 LED25/WW MRPSU GR DX orequivalent in Crompton/Havells/GE |
| 154 | S&F repair LED luminaire 600 mm x 600 mm, 40 watt, 220 V AC recessed/surface type, as directed, with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified & directed. Make: Philips Cat Part no: RC380B LED42S-6500 G6 L60W60 PSU OD S1or equivalent Crompton/Havells/GE |
| 155 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed/surface type, as directed, with high efficiency PMMA diffuser soft glare free light including switching on/off Automatic PIR sensor complete with driver,suitable for roof ceiling including connecting up with driver three core flexible copper conductorof suitable size complete all as specified & directed. Make: RC383B P LED 36S-6500 G6 PSU OD WH PIR Por equivalentCrompton/Havells/GE |
| 156 | Preventive maintenance and checking of Ceiling/Exhaust/wall fan /air circulator / table fan / padestal fans of any size / type / make, checking the serviceability of safety pins, clamps, down rods, rubber bushes, nuts, bolts, canopies, replacement of bearing, and electric connections etc, connecting / hanging in original position, reconnecting the electric cables and writing MES No.and testing complete all as specified & directed. |
| 157 | Checking, fixing, cleaning and caliberation of elctric meter installed atdifferent location complete all as specified and directed. |
| 158 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300msweep with, blades, and frame and louvers of Make : Bajaj / Crompton /havells and also carefully taking down old /unsvitem of any make/model anddepositing it inMES store of AGE E/M (P) Jabalpur complete all as specified and direct complete all as specified and directed . |
| 159 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) , Make : Havells , Atomberg, Bajajalso carefully taking down old /unsvitem of any make/model and depositing it inMES store of AGE E/M (P) Jabalpur complete all as specified and directed |
| 160 | Supply and Fix in repairs driver for LED fitting 2\"\" x 2\"\" of 36/40/45 watt as per sample available complete all as specified and as directed. |
| 161 | Supply and fixing in replacement of Unserviceable running capacitor 220-240 volt , 50 HZof 2.5 MFD capacity including taking down old running capacitor (Suitable for ceining fan/ ex fan)complete all as specified & directed. |
| 162 | S&F in repair LED bulk head luminaires 10 W 6000k Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head Back-lit LED uminaire comprising of high brightness LEDs. complete all as specified & directed. Make-Havells Cat No.HEXAFT10WLED857SSYMBOPC or eqvt make Philips/Wipro |
| 163 | Supply & fix in replacement ofBldg LED Security Light Luminaire 45 wattwith 4500 or more lumen warm white, surge protection device upto 4KV, IP65/66 or more, IK07 or more, potted driver suitable for 180 to 270 V, 50 Hz, light engine driver base.pole adapter, powder coated pressure die cast aluminium with heat resistant toughened glass with lens type,GI pipe 25 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos ofpole fitting clamps made out of MS flat , nutsand boltsand painting with aluminium paint complete all as specified and as directed. Make: Philipscat part no: BRP029 LED45/WW MRPSU GR DX or havells cat part no.ENDURASUNDOWNSL45WLED765PASYBOPCIHD or equivalent in wipro/GE |
| 164 | M&L in repair Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means ofnut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
| 165 | M&L for providing earthingfunnel with all relevent items and PCC cover including white wash and writing Earth pit No including testing of earth resistance complete including removing all as specified and directed. |
| 166 | S&Fknobs for window AC, including taking down old switch complete any make and any size, complete all as specified and directed. |
| 167 | S&F in replacement of volt meter range 0 to 300 volts, flush type square or circular for voltage stabilizer complete all as specified and directed. |
| 168 | S&F in replacement of old/UNSV fan motor 230 volt, 50 Hz for 1/4 and 1/6 HP suitable for AC window type and split typecomplete all as specified and directed. |
| 169 | Taking down carefully following item of any make/model after repair refixing of sameor other position or depositing in MES store of AGE E/M (P) Jabalpur complete all as specified and directed: |
| 170 | Desert cooler of any make and size |
| 171 | Window AC/Split AC of any capacity /position |
| 172 | Servicing ofsplit type AC including pressure testing of AC, cleannig of indoor unit with blower & outdoor unit of AC washing, filter cleaning,copper tubing check etc,complete all as specified and directed. |
| 173 | Servicing of window AC type including pressure testing of AC ,cleannig ofunit with blower , washing, filter cleaning,copper tubing check etc, forcomplete all as specified and directed. |
| 174 | M&L in replacement of old/UNSV Ply-wood grade BWR type BB 6mm thick (five Ply) cut into required size fixed where required with all fixing are complete all as specified and directed. |
| 175 | M&L for replacement of old/UNSV Running capacitor 50.0 mF for AC,desert Cooler, any type and ISI make complete all as specified and directed . |
| 176 | S&F in replacement new thermostate for AC, complete all as specified and directed. |
| 177 | S&F MS fan blade of AC unit size450 mm / suitable size including taking out of old unserviceble blade complete all as directed. |
| 178 | S&F in repairs black insulation cover suitable for copper tubing of any size complete all as directed. |
| 179 | Repair and fix PCB (printed circuit board ) units as existing model/make for split / Window type AC 1.5/2 Ton capacity complete all as specified and directed.Make:Blue star/Voltas/LG/Samsung |
| 180 | S&F in replacementwater tray suitable for split AC 1.5/2 Ton capacity, any type and any make/modelcomplete all as specified and directed.Make: LG/Voltas/samsung |
| 181 | S&F in replacementcondensing Coil of window type/ split type AC cap 1.5/2 Ton any type and any make/modelcomplete all as specified and directed. |
| 182 | S&F in replacement cooling coil of window type/split type AC cap 1.5/2 Ton, any type and any make/modelcomplete all as specified and directed. |
| 183 | Replacement of old/unsv PCB with new PCB (printed circuit board ) units as existing model/make for Window type AC 1.5/2 Ton capacity complete all as specified and directed. Make:Bluestar/Voltas/LG/Samsung |
| 184 | M&L for checking the leakage in both low and high side of the system by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leaks including S&F in replacement of Teflon sealing of all refrigerant line valves like liquid lines valves/suction/ discharge valves of compressors, gland packages of all angle valves, flaring of all connections framing welding etc complete all as specified and as directed for the following AC plants:- Note:-Entire work shall be carried out by the Auth rep of OEM i.e Bluestar for following plants: |
| 185 | Central Air Conditioning Plant of Make : Bluestar of capacity(3x25.5) TR |
| 186 | Central Air Conditioning Plant of Make : Bluestar of capacity(3x11) TR |
| 187 | Opening the upper sheet and side sheet of AHU’s of the following central AC plants for access to cooling coil, including M&L for washing/cleaning of cooling coil externally with mild acid (or caustic soda hot water solution) followed by water jet including cleaning/washing of air filters and descaling of cooling coil of AHU,re-fixing and changing of V Belt both set with necessary fitting and T&P for mounting. Note:-Entire work is to be carried out by OEM i.e Bluestar for following plants: |
| 188 | Central Air Conditioning Plant of Make : Bluestar of capacity(3x25.5) TR |
| 189 | Central Air Conditioning Plant of Make : Bluestar of capacity(3x11) TR |
| 190 | M&L for repair of AHU motor suitable for AC plants with following capacity by dismounting it from weather making unit of AHU replacement of Bush, bearing by opening nuts bolts and removing electrical connections of the motor, replacement of V type Belt with new belt, replacement of stator and rotor assemblyrewinding of motor, replacement and alignment of shaft complete all as specified and as directed. Rate is inclusive of the replaced items. |
| 191 | Central Air Conditioning Plant of Make : Bluestar of capacity(3x25.5) TR |
| 192 | Central Air Conditioning Plant of Make : Bluestar of capacity(3x11) TR |
| 193 | M&L for replacement of cast iron Y type strainer of size 50mm flanged type as per existing complete all as specified and as directed.Make: Zoloto/Leader |
| 194 | M&L for evacuation of gas from the system into the empty cylinder (arranged by contrator as required), pumping down to the system, descaling condenser unit of the following capacity plants after bypassing the cooling tower, pumps & supply and circulation of the descalling solution (ANTI SCALENE SCALE FOEE-100) with pump brushing the tubes and where required drilling the stubborn scalling without damaging the tube, replacement of deshed end gasket and unserviceable nuts and bolts assembling back complete testing and commissioning including removing air lock, recharging the gas taken out of the system complete all as specified and directed.Notes:- (i)Descaling pumps, nylon brush, acid including storage containers, drill and drill bits to be arranged by contractor and cost of the same deemed to be included in the rate quoted .(ii) Entire work shall be carried out by OEM i.e Bluestar . |
| 195 | M&L for Vacuum the system and after maintaining vacuum for 24 hours supply and charge refrigerant gas 407 C complete all as specified and as directed by Engr-in-Charge.Make:-Mafron/Refron |
| 196 | M&L for painting of AC Plant as per existing colour including Compressor, condenser, motor, chiller pump, AHU, cooling tower including base and all pipe lines & connected valveetc complete all as specified and directed. Make of Paint-Asian/Indigo or as given in make list. |
| 197 | M&L for repair of indoor type LT panel board and replacement of unserviceable switch/control gears and meters, selector switches, indicator lamps etc including rewiring and extension of incoming and outgoing cables by opening of loops and provisioning of cable lugs /thimbles as required and replacement of rusted sheet metal with existing size MS sheets by necessary arc/gas welding(Approx sheet 1 Sqmtrs ) including two coats of synthetic enamel spray painting over a coat of red oxide primer both inside and outside surfaces of Panel Board including rewriting of identification for controls complete all as specified and directed.Note:- MCCB, contactors, relay, single phase preventer, timer, Change over, Indicator lamp, Selector switch, Ammeter, Voltmeter etc given below will be measured and paid seperately under respective items of this schedule. |
| 198 | M&L in repair for thermal insulation for ducts/chiller with 19mm thick nitrile rubber insulation, complete all as specified and directed |
| 199 | M&L in reapir for air ducting fabricated out of GI Sheet of thickness as under in diffirent size and shape complete all as specified and directed for following gauges: |
| 200 | Made out of 22 Gauge. |
| 201 | Made out of 24 Gauge. |
| 202 | M&L in replacement of PUF insulation 36 mm of density 36 kg/cum and 26 gauge GI cladding complete with necessary mounting arrangement like clamps , nut bolt etc suitable for existing AC Plant cap upto 100 TR complete all as specified and as directed. |
| 203 | M&L in replacement duct filter with ss material filter media capacity shall capable 5 microns as per existing, suitable for AC plant of capacity upto 75 TR, package units as per site requirement complete all as specified and directed. |
| 204 | M&L in replacement strip heaters of cap 3KW (3000 W) complete all as specified and directed. |
| 205 | Taking out the unserviceable motor and rewinding of motor capacity 7.5 HP with same gauge with super enameled copper wire including removing burnt winding cleaning of slots separation of rotor and starter making insulation to all joint and replacement of the following items complete all as specified and directed.(a) Replacement of ball bearing. Make: SKF-02 Nos(b) Replacement of bush (c) Replacement of cooling fan - 01 Nos. |
| 206 | M&L for opening of pump 7.5 HP centrifugal for repair and replacement of following unserviceable parts including re-fixing of all the same and testing and commissioning complete all as specified and asdirected.(a) Replacement of gun metal impeller. -01 Nos (b)Replacement of gun metal bush -02 Nos(c) Replacement of ball bearing. Make: SKF- 01 Nos. (d) Replacement of oil seal -01 Nos. (e) Replacement of gland -01 Job |
| 207 | Attending emergency break down & making functional of AC Plant of Make- Bluestarof capacity 3x 11 TR ventilation system complete exists atNERC OFKJabalpur alongwith equipments as associated .Notes:- (i) The cost of parts/ accessories/ materials if required to be replace, same shall be paid seperately under respective items here-in-after as Supply & fix in replacementas considered/ taken for item No. 02 above.(ii) Emergency break down shall be attend immediately ON CALL, if emergency break down not attended immediately on GE\"s call, a lump sum recovery of Rs. 10000.00 on account of penalty shall be made from the contractor\"s dues/ payment . |
| 208 | Attending emergency break down & making functional of AC Plant of Make- Bluestarof capacity3 X 22.5 TR ventilation system complete exists at LPR Jabalpur alongwith equipments as associated .Notes:- (i) The cost of parts/ accessories/ materials if reequired to be replace, same shall be paid seperately under respective items here-in-after as Supply & fix in replacementas considered/ taken for item No. 01 above.(ii) Emergency break down shall be attend immediately ON CALL, if emergency break down not attended immediately on GE\"s call, a lump sum recovery of Rs. 10000.00 on account of penalty shall be made from the contractor\"s dues/ payment . |
| 209 | S&F in replacement heating coil of suitable layers, shape and size as per existing of capacity 03 KWcomplete all as directed.Make:- Voltas or Carrier or Blue Star or Aeco or Universal as approved by GE. |
| 210 | S&F in replacement cooling coil of suitable layers, for central AC of 11 TR and 22.5 TR capacity, shape and size as per existingcomplete all as directed.Make:- Voltas or Carrier or Blue Star or Aeco or Universal as approved by GE. |
| 211 | M&L in replacement for Cooling tower water collection FRP tray sheet of having dimension (280cm X135cm X 44cm)as existing at LPR Central AC plant Cooling Tower including fixing & leak proof testing complete all as Specified and directed. |
| 212 | M&L for removing the existing choked fins of existing cooling towers and supply and fixing new PVC fins of size suitable for cooling tower of 3 X 25.5 TR or 3 X 11 TRcapcity as per existing complete all as directed. Make:- Voltas or Carrier or BlueStar or Aeco or Universal as approved by GE. |
| 213 | Supply & fix in replacement power contactor 3 pole, ML-2 type with 2 NO + 2 NC aux contracts, 415 Volt, 50 Hz, rating 32 Amps to be fixed under item No. 147.00 here-in-before complete all as directed.Make:- Siemens or L&Tas approved by GE. |
| 214 | Supply & fix in replacement power contactor 3 pole, ML-2 type with 2 NO + 2 NC aux contracts, 415 Volt, 50 Hz, rating 32 Amps to be fixed under item No. 147.00 here-in-before complete all as directed.Make:- Siemens or L&Tas approved by GE. |
| 215 | Supply & fix in replacement MCCB 4P with enclosure, 415 volts, 50 Hz, 400 Amps with breaking capacity 35 kA to be fixed under item No.147.00 here-in-before complete all as directed.Make:- Legrand/L&T/ C&S as approved by GE. |
| 216 | Supply & fix in replacement MCCB 4P with enclosure, 415 volts, 50 Hz, 200 Amps with breaking capacity 25 kA to be fixed under item No.147.00 here-in-before complete all as directed. Make:- L&T/ Legrand/C&S approved by GE. . |
| 217 | Supply & fix in replacement MCCB 3 POLE with enclosure, 415 volts, 50 Hz, 100 Amps with breaking capacity 16 kA to be fixed under item No.147.00 here-in-before complete all as directed. Make:- L&T/ Legrand / C&S as approved by GE. |
| 218 | Supply & fix in replacement power indication lamps with complete accessories 230 volts, single phase as per existing duly approved by Engr-in-Charge to be fixed under item No. 147.00 here-in-before complete all as directed. |
| 219 | Supply & fix in replacement voltage selector switch complete 230 volts, as per existing duly approved by Engr-in-Charge to be fixed under item No. 147.00 here-in-before complete all as directed. |
| 220 | Supply & fix in replacement ampere selector switch complete 230 volts, as per existing duly approved by Engr-in-Charge to be fixed under item No. 147.00 here-in-before complete all as directed. |
| 221 | Supply & fix in replacement over load relay range 9 to 15 Amps, MN-2 type to be fixed under item No.147.00 here-in-before complete all as directed. |
| 222 | Supply & fix in replacement over load relay range 3 to 5 Amps, MN-2 type to be fixed under item No. 147.00 here-in-before complete all as directed. |
| 223 | Supply & fix in replacement butter fly valve with side handle operated type of 80 mm dia to be fixed under item No147.00 here-in-before complete all as directed. |
| 224 | Supply & fix in replacement butter fly valve with side handle operated type of 100 mm dia to be fixed under item No. 147.00 here-in-before complete all as directed. |
| 225 | Supply & fix in replacement temperature gauge (digital type) bottom connected, direct mounting type, range 0 to 100° C or 32 to 212°F complete as per existing make duly approved by GE to be fixed under item No. 147.00 here-in-before complete all as directed. |
| 226 | Supply & fix in replacement V belt \"B\" section of size A-56 as per existing to be fixed under item No. 147.00 here-in-before complete all as directed. |
| 227 | Supply & fix in replacement water flow switch of type RC-61 MWP 150 PSI electric rating 250 volts, 50Hz, 15 Amps with sensor and lead as per existing make duly approved by GE to be fixed under item No. 147.00 here-in-before including testing and commissioning complete all as directed. |
| 228 | M&L for dismantling & taking out the old unserviceable/ burnt winding wire after taking out the 3 phase, 50 Hz, 415 volts electric motor of capacity 3.0 HP from existing position and rewinding the same with superior quality copper winding wire of suitable gauge and number of turns including insulating materials (PVC insulation sleeve, tape, film paper, varnish, cotton & heating process etc) as required including replacement of existing DE & ND side bearings and re-fixing the motor in existing position after re-assembling and testing on completion complete all as specified & directed. |
| 229 | M&L for dismantling & taking out the old unserviceable/ burnt winding wire after taking out the 3 phase, 50 Hz, 415 volts electric motor of capacity 5.0 HP from existing position and rewinding the same with superior quality copper winding wire of suitable gauge and number of turns including insulating materials (PVC insulation sleeve, tape, film paper, varnish, cotton & heating process etc) as required including replacement of existing DE & ND side bearings and re-fixing the motor in existing position after re-assembling and testing on completion complete all as specified & directed. |
| 230 | M&L for repair/ overhaulling of hot water generator of capacity 54 KW out put by unscrewing and draining out to detect leakages, welding where-ever necessary, removing burnt/ unserviceable heating element from bottom level of tank, scraping out rust/ sludge including putting new insulation sleeves to bare conductors, fixing ofnew/ fresh heating elements of suitable capacity, replacement of PCC kit with new one and reassembling all the dismentled components and testing on completion for satisfactory operation complete all as specified & directed. |
| 231 | M& L in replacement for perforated cable tray of size100x 50 Galvenised Iron for support of cablesfrom AHU to AC plant including all fixing accessories ,nuts, bolts and proper supportof MS channelsand connected fixing aarangements all as specified and directed. |
| 232 | M&L for complete repair/ over-hauling to FRPbased cooling tower of 3 X 11 TR capacity by dismantlinlg fins, couplings, cooling fan, draining out of water movingalgey deposited and cleaning,servicing of mechanical components, welding wherever necessary, scraping out rust/ sludge including putting descaling solution and replacing of gear box, bearings, gear oil, mechanical couplings as per site requirement and over-hauling the complete transmission system of cooling tower and painting the complete system as per existing duly approved by GE and reassembling all the dismentled components and testing on completion for satisfactory operation complete all as specified & directed. |
| 233 | M&L for complete repair/ over-hauling to FRPbased cooling tower of 3 X 25.5 TR capacity by dismantlinlg fins, couplings, cooling fan, draining out of water movingalgey deposited and cleaning,servicing of mechanical components, welding wherever necessary, scraping out 1ust/ sludge including putting descaling solution and replacing of gear box, bearings, gear oil, mechanical couplings as per site requirement and over-hauling the complete transmission system of cooling tower and painting the complete system as per existing duly approved by GE and reassembling all the dismentled components and testing on completion for satisfactory operation complete all as specified & directed. |
| 234 | M&L for PVC mat of size not less than 2.0M X 1.0M X 20-25mm thick of colour and design as approved GE complete all as specified & directed.Make:- CELLO or SUPREME or AMKO as approved by GE. Note:- Mat shall be of standard class PVC but not re-cycled. |
| 235 | Supply and fix in Repairpressure gauge of size4\"dial 0-10 kg/cm2 rating including fixing accessories valve ,threads ,pop and checking for leakages if any,as per existing make duly approved by GE complete all as specified & directed. |
| 236 | Supply and fix in Repairpressure gauge of size4\"dial 0-15 kg/cm2 rating including fixing accessories valve ,threads ,pop and checking for leakages if any, as per existing make duly approved by GE complete all as specified & directed. |
| 237 | Supply & fix in repairdischarge non return sluice valve of dia 80 mm as per existing duly approved by GE suitable for Air Conditioning Plantafter shut down the air conditioning unit & opening of compressor and taking out of old unserviceable discharge NRV and leakage testing on completion at desired pressure and commissioning complete all as specified & directed. |
| 238 | Supply and fix in repairs, 35/36 watt new generation energy saving and environmental friendly long life LED security light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening seperate driver compartment with IP66 protection and impact resistance of IK07 on bldg wall with and including pipe bracket made out of G.I tubing 32/40 mm dia bore medium grade ISI marked 1.20m long bent to shape & providing clamps 2 Nos made out of 50 x 6 mm Flat iron/ MS clamps & 12mm dia bolts, nuts & washers etc and two coat painting of approved colour on brackets compltely with and including synthetic enamel paint and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed.Make:- Havells Cat part No. ENDURAPEARLNEOSL40WLED757PASYTOPC or equivalent model of make- Philips or Crompton or WIPRO or Bajaj as approved by GE. |
| 239 | Supply and fixing in repairRELATIVE HUMIDITY-TEMPERATURE INDICATOR CUM CONTROLLER-Model No. : LIM N480D- PID Control: ON/OFF- double LED display 4-digits- Auto Tuning- adjustable offset for the sensor- programmable outputs- 3 programmable control/alarm outputs- heating function- ramping: 1x9 segments- sensor damage detection- sampling rate: 5 measurements per second- simple configuration menu- front panel: IP65, Polycarbonate UL94 V-2- USB inter phase for configuration- 15 bit analog-to-digital transmitter |
| 240 | Earthing complete for various equipments with galvanised steel earth plate electrode600 x 600x 6mm thick directly burried in the ground (earth pit not less than 2.25 metre deep below ground level) with top edge of earth plate not less than 1.5 m below the ground level, connected to G.I Strip 32 x 6 mm by means of bolts, nuts, chuck nuts and washers of galvanised iron or steel, GI pipe 40mm bore light grade for protection of earthing strip, PCC chamber 1:4:8, type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 12mm thick plaster in CM 1:4, funnel with wire gauge of 22 gauge (0.63) 8 mesh per linear inch, 50mm thick cover of RCC 1:2:4, type B-1, using 20mm graded stone aggregate reinforced with 8mm TMT bar at 100mm centerto center both ways and charcoal dust and common salt all as shown in electrical plate No.3 of MES SSR Part-I and as specified including excavation and earth work and connecting the earthing to an earthing test point as specified and testing on completion all as directed.Note:- Unit rate quoted is inclusive of earth lead and protection pipe upto 7.5 metre from earth plate. |
| 241 | Schedule of credit of amount Rs. 93881.00 to de deducted during SOC |