| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-12-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 23-12-2025 |
| Sl. No. | Item Description |
| 1 | Taking down chowkats or frames with shutter (without taking off shutter from the frame) n. exc 1.5 sqm each including cutting holes for taking out hold fast or dismantling brick work and removing from site complete all as specified and directed. . |
| 2 | Taking down chowkats or frames with shutter (without taking off shutter from the frame) exc 1.5 sqm & n. exc 4 sqm each includingcutting holes for taking out hold fast or dismantling brick work and removing from site complete all as specified and directed. |
| 3 | S&F steel window/ventilator 1.25 mm thick Box type (Double Shutter) ERW hollow P section of size 60 mm x 25 mm single rebated comprises glazed & wire gauged skelton shutter ERW sec 50 mm x 20 mm and 1 mm thick with two Nos sash bar of T- section 20 mm x 3 mm complete welded to frame with one vertical mullion of ERW box type T- section of size 60 mm x 25 mm and 1.25 mm thick including cutting holes and making good dismantled portion in PCC 1:2:4 type B-1 four No for each window including following fitting welded to frame shutter hold fast of 150 mm long of 12 mm x 3 mm FI made to shape 4 No, handle of Z section 20 mm x 25 mm x 100 mm long 1 No per leaf, MS tower bolt 150 mm long 2 No per leaf, Z sec 20 mm x 25 mm, 100 mm long stopper 1 No on per leaf, MS pintal hinges of size 75 mm x 12 mm 2 No per leaf fabrication, as per drg No CEPZ/TD-324,325 complete all as specified and directed. Note: - The quoted rate shall be deemed to include:-(i) 04 Nos MS steellugs of MS flat 20 x 5mm& 20 cm long over all welded to frames (ii) PCC block for embedding lugs. |
| 4 | S&F pressed steel frames of size 125mm x 60 mm made out of size 1.25 mm thick MS sheet for doors with one or more rebate including mild steel hinges, 100 mm long , medium weight and 25 mm x 3 mm flat iron as in hold fast , tie bar including necessary fixing lugs, lock strike plate and fixing arrangement and making good the disturbed surfaces in cement mortar 1:3 or cement concete 1:2:4 type B-1 including PCC 1:3:6 type C1 as in back fill to chowkats complete all as specified and directed. |
| 5 | S&F pressed steel frames of size 105mm x 60 mm made out of size 1.25 mm thick MS sheet for doors with one or more rebate including mild steel hinges, 100 mm long , medium weight and 25 mm x 3 mm flat iron as in hold fast , tie bar including necessary fixing lugs, lock strike plate and fixing arrangement and making good the disturbed surfaces in cement mortar 1:3 or cement concete 1:2:4 type B-1 including PCC 1:3:6 type C1 as in back fill to chowkats complete all as specified and directed. |
| 6 | M&L for 30mm thick flush shutters, solid core construction with block board core and plywood face panels commercial type on both sides complete all as specified and directed. |
| 7 | S&F 35 mm thick 2nd class hard wood , glazed and skelton shutters, open rebated and prepared to receive glass, gauze etc divided into squares with plain, chamfered or rounded, mitred and rebated sash bars, any numbers size of members of shutters as specified in SSR Part-I Section-8 clause 8.24 (a) fitted to chowkats complete all as specified and directed. |
| 8 | S&F SolidPVC door frame of size 50mm x 47 mm made out of 5mm wood grain printed PVC sheet reinforced with M.S. square tube, egdes will be painted to match printed sheets completeall as specified and directed .. |
| 9 | S&F Factory Made Solid PVC Moulded Door Shutter, with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm Plain colour PVC Sheet on back face, supplying & fixing in frame at site as per specification & drawing all as specified and directed |
| 10 | S&F aluminium anodised barrel tower bolts, 200mm long of extruded section, fixed to doors with screws complete all as specified and directed. |
| 11 | S&F aluminium anodised , cast type handle 150mm size complete all as spcified and directed. |
| 12 | S&F aluminum alloy, anodised, sliding door bolt of length 250mm with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolt and sliding bolts of extuded sections or cast aluminum alloy and fixed complete all as specified and directed. |
| 13 | S&F140 mm floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 14 | S&F300 mm mild steel, ordinary rat tail rod pattern spring including roller and roller plate including fixing to pressed steel frames with necessary welding work complete all as speciied and directed |
| 15 | S&FButt hinges 100mm extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 fixed with screws complete all as specified and directed. |
| 16 | M&L for 4 mm thick, plain sheet glass, ordinary quality and glazing with glazing pins, oil putty or with any type of beadsin squares n. exc 0.5 sqm each pane complete all as specifiedand directed. |
| 17 | S&F 4mm thick, figured glass, pin head type, ordinary quality and glazing with oil putty or any type of beadsin squares n.exc 0.5 sqm each pane complete all as specified and directed. |
| 18 | S&F galvanised mild steel wire cloth , 0.56 mm normal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or stainless steel wire staples complete all as specified and directed. |
| 19 | M&L for pressed steel cup board frame made out of MS sheet 1.25mm thick, size of frame 60 x 40 mm with rebate of 20 mm wide and 12 mm deep including PCC 1:2:4 type B-1 as in filling to back of chowkatscomplete all as specified & directed. |
| 20 | S&F Prelaminated MDF board 19 mm thick ,exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,as in shutters/ shelves fixed with screws to timber frame work including lipping (15 mm thick three sides and 20 mm thick lipping hinge side) around the shutter complete all asspecified and as directed . |
| 21 | S&F continuous (piano) hinges,width of flaps (when open) 30 mm,heavy duty, mild steel, bright finish or electrogalvanised sutable for 19mm thick shutter and fixed, complete all as specified and directed. |
| 22 | S&F aluminium anodised , fabricated type handle 100mm size complete all as spcified and directed. |
| 23 | S&F in repair 25mm outer dia stainless steel decorative drapery rod of thickness 20gauge with stainless steel brackets near toends with stainless steelfinialsat both ends and necessary fittings complete all as specified and directed. |
| 24 | Demolition of brick work or stone/boulder masonry , built in cement mortar or cement lime mortar including all quoins, arches & pillars etc of any description and in any position and removingunserviceable material from work site to outside defence premises complete all as specified and directed |
| 25 | M&L for brick work with sub class \"B\" bricks, using old size bricks, straight or curved on plan exceeding 6m mean radius , built in cement mortar 1:6 complete all as specified and directed |
| 26 | All as per Srl item No -25 here-in-before but except bricks complete all as specified and directed |
| 27 | M&L for brick work with old size sub-class \"B\" bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed . |
| 28 | Taking down cement plaster of any description on brick or stone walls or from concrete surface including raking out joints, hacking for key, scrubing down with water etc and removing unserviceable material outside defence land complete all as specified and directed. |
| 29 | M&L for rendering 10mm thick in cement mortar 1:6 on brick work or concrete surfaces, surface finished even and smooth without using extra cement complete all s specified and directed. |
| 30 | M&L for rendering 15mm thick in cement mortar 1:4 on brick work or concrete surface,surface finished even and smooth without using extra cementcomplete all as specified and directed. |
| 31 | M&L for rendering 5 mm thick in cement mortar 1:3 on ceiling, surface finished even and smooth without using extra cement complete all as specified and directed. |
| 32 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceabletiles to store and rubbish off the premises complete all as specified and directed |
| 33 | M&L for 7 to 8mm thick non skid colouredceramicjoint less tiles (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding0.18 sqm, in floors etc, set and jointed in neat cement slurry and poined in white or coloured cement to match the colour of tiles over and including 15mm thick screed bed in cement motar 1:4 complete all as specified and directed. |
| 34 | M&L for glazed ceramic coloured digital tiles,300x600x7 to 8 mm thick, as in vertical surfaces, set and jointed in neat cement slurry and pointed in white or colored cement to match the colour of tile over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 35 | M&L for 8 to 9 mm thickvitrifiedceramic , coloured or printed light shade,joint less,edge cut tiles (square/ rectangular) polished,area of each tiles not exceeding 0.36 sqm , in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed. |
| 36 | M&L for 8 to 9 mm thickvitrifiedceramic , coloured or printed light shade,joint less,edge cut tiles (square/ rectangular) polished,area of each tiles not exceeding 0.36 sqm ,as in vertical surfaces, set and jointed in neat cement slurry and pointed in white or colored cement to match the colour of tile over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 37 | Demolition of plain cement concrete (un-reinforced)of any description and in any position not otherwise specifically provided and including removing from site to a distance n exc 500 mtrs , complete all as specified and as directed. |
| 38 | M&L for 75 mm thick plain cement concrete 1:3:6, type C2 (using 40mm graded crushed stone aggregates)as in sub base offloors/hardstanding, finished even and faircomplete all as specified and as directed. |
| 39 | M&L for machine pressed chequered cement concrete tiles 30cmx30cmx25mm thick, with grey cement and pigment, set ,jointed and pointed in neat cement slurry & polished as in floors, laid over and including 20mm thick screed bed in cement mortar 1:4 complete all as specified and directed. |
| 40 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. and brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified and directed |
| 41 | S&F machine cut kota stone slab in flooring, treads of steps(one piece including rounding/ mouldings of edges of treads), 20-25 mm thick, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing cutting and mirror polishing over and including 15 mm thick screed bedin cement mortar 1:4 complete all as specified and directed. |
| 42 | M&L for machine cut kota stone slab 20-25 mm thick in riser of steps, skirting , dado and pillar, laid and jointed with grey cement slurry mixedwith pigment to match the shade of the slab including rubbing, cutting and mirror polishing over and including 10 mm thick rendering in cement mortar 1:4 after roughing surfaces of old concrete /any type of plaster by picking sweeping down with water to remove dust etc complete all as specified and directed. |
| 43 | M&L for glass fibre reinforced modified cementitious coating system before the final coat of Latex Shield 2K (or equivalent).Base coat: Berger HS Latex plus (or equivalent) both on wall (upto 1 mtr min height) and floor.Consumption base coat: 0.3 kg/sqmReinforcement: Glass fiberSecond and Third coat: Latex sheild 2K (or equivalent) both on wall (upto 1 mtr min height) and floor.Consumption top coat: 3 kg/sqmSystem requirements: density: 2.00 kg/ltrcompressive strength: 0.5 N/mm².• Wall penetration through the RCC slab must be sealed using Berger HS RepirO(or equivalent).• Intersection of base slab with wall must be provided with a 50 mm fillet using Berger HS Latex plus(or equivalent) modified mortar with a bonding coat of Berger HS Latexplus(or equivalent) modified cement slurry upto 5ft.• All depressions, unevenness, surface honeycombing shall be repaired using Berger HS Latex plus (or equivalent) modified polymer mortar with a bonding coat of Berger HS latex plus(or equivalent)modified cement slurry including cleaning ofRCCsurface to remove dust, loose particles, etc with compressed air or any other suitable technique depending on site conditions, grinding any sharp edges, etc |
| 44 | M&L for rendering 10mm thick in cement mortar 1:4 as in sunken floors/walls , surface finished even and smooth without using extra cement including mixing of water proofing compound complete all as specified and directed Note :- WPC shall be measured and paid separately. |
| 45 | M&Lfor plain cement concrete 1:5:10 type E2 (using 40 mm graded crushed stone aggregates) in sunken filling(upto 2nd floor) and mass concrete complete all as specified and directed |
| 46 | Supply only liquid water proofing compound. |
| 47 | S&F 20 mm dia High density polyethylene pipes (HDPE) of pressure rating 6 Kgf/cm2 laid in as spout pipes to pour out residual water out from the treated area complete all as specified and directed. |
| 48 | M&L for capillary rise treatment of walls with following specification:-Base coat: Berger HS Latex plus or equivalent in make specified in PSConsumption base coat: 0.3 kg/m2Second and Third coat: Latex sheild 2K or equivalent in make specified in PSConsumption top coat: 3 kg/m2System requirements: density: 2.00 kg/ltrcompressive strength: 0.5 N/mm2. |
| 49 | M&L for 50mm thick PCC 1:3:6 , type C-1 (using 20 mm graded crushed stone aggregate) as in plinth protection, laid in slope in 1:30 in alternative bays not exceeding 3 mtr in length. surfaces finished even and fairincluding raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:2 complete all as specified and directed . |
| 50 | M&L for rolled mild steel as in compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc of Fe 410-W (Gde 250) quality A complete all as specified and directed . |
| 51 | Dismantlingwall and ceiling boards (fibre,pulp, insulation) or insulation boards/ slabs/ blankets, any thickness, including cover fillets etc complete all as specified & directed. |
| 52 | S&FGI snap grid frame work (Grid size 605mm x 605mm) for false ceilingconsisting of main runner \"T\" of size 24mm x 32mm and 0.3mm thick , Secondary runner \"T\" of size 24mmx25mm and 0.3mm thick,GI angle24mmx24mm and 0.4mm thick,Bottom exposed capping of width 24 mm of all T-sections shall be of 0.25mm thick PPGI, hot dipped galvanised steel with zink coating not less than 120gm / Sqm ,ceiling grid system duly suspended by 4mm dia GI wire hanging from existing purlins /roof slab with butterfly clipsincluding Gypsum ceiling tilesof size 595 x 595 x 9 mm laminated with 0.07 mm thick polyvinyl film on the face side and 10 micron metalized polyester film on the back side fixed on GI snap gridcomplete all as specified and directed .. |
| 53 | Taking up or down 15mm dia GI tubing and connections including cleaning for refixing or removal to store complete all as specified and directed |
| 54 | Taking up or down 20mm dia GI tubing and connections including cleaning for refixing or removal to store complete all as specified and directed |
| 55 | M&L for cutting (in brick walls) chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sun shades, shelves, Iintels etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting exc 20cm grith complete all as specified and driected. |
| 56 | S&F Galvanised steel tubing, 15mm bore, medium grade with all fittings, fixed to wall/ceiling and or in floors complete all as specified and directed |
| 57 | S&F Galvanised steel tubing, 20mm bore, medium grade with all fittings, fixed to wall/ceiling or laid in floors complete all as specified and directed |
| 58 | M&L for dismantling of water tank of capacity exc 500 n. exc 1000 ltrs and removing complete all as specified and directed. |
| 59 | S&F Rotational moulded polyethlene water storage tanks of 1000 litres capacity (cylindrical vertical with closed top) with plastic lid cover, hoisted and fixedin position including PTMT Ball valves high pressure with epoxy coated aluminum rod & high density plastic ball complete, screwed for iron pipeor brass ferrule and fixed for 20 mm bore pipe including making connections complete all as specified and directed. |
| 60 | S&F20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed . |
| 61 | Dismantling PVC/Cement/CI pipes 50 to 110 mm dia including all fittings and removing from site complete all as specified and directed |
| 62 | S&F UPVC (SWR) type B pipes, 110 mm bore, single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 63 | S&F UPVC (SWR) type B pipes, 110 mm bore, single socketed, in any length with rubber ring joints fixed to walls with nail at spacing of 1m center to center including stack clamp of GI flat 30mm wide 2mm thick complete all as specified and directed. |
| 64 | S&F UPVC (SWR) type B pipes, 75 mm bore, single socketed in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed. |
| 65 | S&F UPVC (SWR) type B pipes, 75 mm bore, single socketed, in any length with rubber ring joints fixed to walls with nail at spacing of 1m center to center including stack clamp of GI flat 30mm wide 2mm thick complete all as specified and directed. |
| 66 | S&F UPVC (SWR) bends any radius, 110 mm bore complete all as specified and directed |
| 67 | S&F UPVC (SWR) bends any radius, 75 mm bore complete all as specified and directed |
| 68 | S&F UPVC (SWR), junction single, (single \"T\")equal or unequal for 110 mm bore complete all as specified and directed |
| 69 | S&F UPVC (SWR), junction single, (single \"T\")equal or unequal for 75 mm bore complete all as specified and directed |
| 70 | S&F UPVC (SWR) bends with access door any radius, 110 mm bore complete all as specified and directed |
| 71 | S&F UPVC (SWR),branch single, (single \"Y\") with access door equal or unequal for 75 mm bore complete all as specified and directed |
| 72 | S&F UPVC (SWR),branch single, (single \"Y\") with access door equal or unequal for 110 mm bore complete all as specified and directed |
| 73 | S&F UPVC (SWR), reducers 110 mm dia complete all as specified |
| 74 | S&F UPVC (SWR) vent cowl 75 mm dia complete all as specified |
| 75 | S&FUPVC (SWR) multi floor trap plain with grating having diameter of outlet 75 mm including jointing with solvent cement to waste pipe, laid in cement concrete 1:2:4 type B-1 complete all as specified and directed. |
| 76 | S&F UPVC (SWR) floor trap plain with grating having diameter of outlet 63 mm including jointing with solvent cement to waste pipe, laid in cement concrete 1:2:4 type B-1 complete all as specified and directed. |
| 77 | S&F UPVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed. |
| 78 | S&F bib tap with long body, chromium plated, fancy type, cast copper alloy , screwed down, screwed for 15 mm bore of iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 79 | S&F angle valve with flange,cast copper alloy , fancy type, chromium plated, screwed down for high pressure , screwed both ends for iron pipe of 15mm bore complete all as specified and directed. |
| 80 | S&F central hole basin mixer without popup waste system with 450mm long braided hoses, screwed down for 15mm bore iron pipe complete all as specified and directed. |
| 81 | S&F wall mixer 3-in-1 system with provision of overhead& hand shower complete with 115mm long bend pipe, connecting legs & wall flange fancy type complete all as specified and directed. |
| 82 | S&F brass chromium plated shower rose 125 mm of size with arm and with or without swivel joints to steel pipe or union complete all as specified and as directed. |
| 83 | S&F PTMT cabinet with mirror of size 330x430mm fixed with screws complete all as specified & directed |
| 84 | S&F in repair vitreous china wash hand basin, white, flat back of size 550x400mm including cutting for and pinning in ends of brackets or erecting stand including cast iron brackets, brass chromium plated waste coupling 32mm bore, waste pipe PVC 32mm bore complete all as specified and directed |
| 85 | S&F vitreous china wash down water closet pan (pedestal pattern)of size 520x360x390mm , white in colour including connection pipe to union of flushing cistern, inlet and overflow pipes, connecting only to flushing cistern, anti-syphonage pipe with PVC flush pipe of 32mm dia including plastic seat with cover, white in colour with mild steel chromium plated hinging and \"P\" or \"S\" trapcomplete all as specified and directed |
| 86 | S&F 10 litres PVC, valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float 32mm PVC \"L\" bend and handle including brackets complete all as specified and directed |
| 87 | S&FChromium plated soap dish of size 160x160x90mm, any type, fixed to plugs with chromium plated brass screwscomplete all as specified and directed. |
| 88 | S&F brass chromium plated tubular rail 20mm dia, D type , 600 mm long between flanges fixed with CP brass screws including wooden/plastic beads complete all as specified and directed. |
| 89 | S&F brass chromium plated tubular towel ringof 150mm dia, fixed with CP brass screwsincluding wooden/plastic beads complete all as specified and directed. |
| 90 | S&F stainless steel square foldable towel rack,600mm size complete all as specified and directed. |
| 91 | S&F sheet glass shelf assembly consisiting of 5.5 mm thick sheet glass, shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed. |
| 92 | S&Fcorner glass shelf of size 30cm with chromium plated bracket guard and railing fixed with and including screws and wooden/plastic cleats complete all as specified and directed . |
| 93 | S&F health faucet (ABS Body) mild steel chromium plated suitable for 8mm dia pipe with 1.20 metre long flexible tube and ABS wall hook including making connectios and fixed in position complete all as specified and directed. |
| 94 | S&FPVC connection 15 mm x 600 mm including PVC check nut at both ends complete all as specified and direced. |
| 95 | S&F600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed |
| 96 | M&L for plain cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregates) as in padding over roof, finished & laid to required slope complete all as specified anddirected . |
| 97 | M&L for rendering 15mm thick in cement mortar 1:4 on concrete surfaces of roof finished even and fair including mixing of water proofing compound as per manufacturer\"s instructions complete all as specified and directed. Note : Water proofing compound shall be measured and paid separately as supply only. |
| 98 | Complete removal of existing water proofing treatment of any description including under layer, taking downcement plaster & concrete, any thickness and preparation of concrete surfaces by scrubbing down with steel brushes and cleaning with water to remove all loose dirt/dustand removal of debris off the premisesincluding grubbing up of trees complete all as specified and directed. |
| 99 | M&L for water proofing treatment to roof surface (in four coat) with fibre reinforced elastometic liquid water proofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibres with sun reflective index (SRI) of 100-110 having minimum elongation of 350%, tensile strength 2.9 MPa and shall have rack bridging ability upto 10 degree celcius to RCC roof slabs, roof treatment shall be carried out in four coats to newly plaster roof surface as per the procedure given below :-(a) Apply first coat of fibre reinforced elastometic liquid water proofing membrane as described above with 33% dilution as priming coat as directed and allow it to dry before next coating. (b) Laying second coat of fibre mesh 0.3 mm thickness weave in leno pattern having weight 45 gms per sqm and pasting it properly with overlap of 50 mm as directed and allow it to dry before next coating.(c) Apply third coat of fibre reinforced elastometric liquid water proofing membrane as described in para (a) above but undiluted @ 0.45 litre per sqm of roof surface as directed.(d) Apply fourth and final coat of fibre reinforced elastometric liquid water proofing membrane as described in para (a) above but undiluted @ 0.45 litre per sqm of roof surface as directed.(e) Ther water proofing treatment shall be carried out by the authorised applicator of manufacturer and shall be approved by the GE before commencement of roof treatment work. |
| 100 | M&L for preparation of new or previously untreated steel surface of any description over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed |
| 101 | M&L for preparation of new or previously untreatedwood or wooden based surfaces of any description not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 102 | M&L for preparation of old painted steel surfaces of any description over 10cm width or girth not otherwise described to make surface even and smooth & apply primer where required and applying one coats of synthetic enamel paint complete all as specified and directed. |
| 103 | M&L for preparation of old painted wooden surfaces of any description over 10cm width or girth not otherwise described to make surface even and smooth and apply putty & primer where required and applying one coats of synthetic enamel paint complete all as specified and directed. |
| 104 | M&L for complete removal of existing treatment on wall/ceilling,roof projectios,Including facia,cornices etc by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7\"/9\" to make the surface free from dust, loose paint etc. by skilled labour complete all as specified and directed . |
| 105 | M&L for water proof cement based putty @ 1kg (undiluted) per sqm of average thickness 1 mm over the plastered painted exterior wall surfaces of walls (upto 4th storey with necessary scaffolding )including prepartion of surfaces by scarpping to prepare the surface and sanding of the putty surfaces with mechanical wall sander (having mechanical vaccum mechanism ) having RPM not less than 1500 ,sanding pads of 240 Grit or above to make the surface free from dust etc by skilled llabour as per following steps:-Steps 1:- Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of minimum 2.5 kg putty per minute.Step 2:- Apply the first coat of prepared mixer with the manually required help of fully automatic airless spary machine of putty application, finishing the surface even and smooth in level without any undulation.Step 3:- Allow 6 to 8 hour time to dry the putty surface, Apply the further more coat of preparaed mixer with the help of fully automatic airless spary machine of putty application, finishing the surface even and smooth in level without any undulation. |
| 106 | M&Lfor one coat of acrylic water based exterior grade primer @ 0.9 ltrs (undiluted) per 10 sqm, diluted with water in 1.1 ratio to be applied with fully automatic airless spary machine of paint application with a flow speed of min 1 litres per mintues having a pressure of 3300 PSI and Allow 6 to 8 hours to dry surface for painting of subbsequent coats (walls up to 4th storey with necessary scaffolding)complete all as specified and directed . |
| 107 | M&L for water based premium acrylic smooth exterior emulsion of approved colour with silicon additive excellent dirt pick up resistance with low VOC less than 50 Antifugal, Anti Algai properities in two coats @ 1.79 lites (undiluted) per 10 Sqm diluted with water as per manufacturer instructions applied over priming surface in between subsequent coats of paint (upto 4th storey with necessary scaffolding) complete all as specified and directed . |
| 108 | M&L for water based premium acrylic smooth interior emulsion of approved colour with silicon additive excellent dirt pick up resistance with low VOC less than 50 Antifugal, Anti Algai properities in two coats @ 1.79 lites (undiluted) per 10 Sqm diluted with water as per manufacturer instructions applied over priming surface in between subsequent coats of paint (upto 4th storey with necessary scaffolding) complete all as specified and directed .Notes for Srl item No 104to 108 of BOQ :- (a) The work for periodical services shall include the under mentioned aspects and the rates quoted by the bidder shall includes and the same & nothing extra shall be payable.(i) Workshall be carried out by the authorised applicator of manufacturer of water based premium acrylic smooth exterior emulsion, contractor shall submit a triparty agreement MoU (between contractor ,said manufacturer and their authorities appicator ) on Non judicial stamp paper to GE and shall be approved by the GE before commecement of work at site. (ii) Workshall be carried out up to 4th storey height buildings and the necessary scaffolding , trestles , ladders ,cradles & safety measures shall be arraged by the contractor for labour and their own .(iii) Removing of nails & making good holes, cracks etc. (iv) Work in patches and in narrow /widths ,bands ,cornises ,plasters etc shall also be carried out and cutting in edge of line where ncessary. (v) Spreading and removing covering to doors ,windows ,floor ,fittings etc to protect them from splashes.(vi) Washing floors , cleaning glass ,joinery, fittings, wiring etc from drops and splashes of paint to be cleaned to the statisfaction of Engineer-in-charge.(vii) Sample patch of 10 sqm be prepared considering all the items of periodical and shall be got approved from GE prior to carrying out further work. |
| 109 | Taking down carefully existing aluminium/copper point wiringfor light, fan, socket or power bell complete with fittings such as Switches, sockets, ceiling roses, holders, call bells etc & making goodthe disturbed surfaces of walls/ceiling, matching the colour with existing surface complete all as specified and directed.Note : Rate for making good shall be deemed to be included in above item rate. |
| 110 | Taking down ofunserviceableMCB DB, SPN /TPN along with MCB\"s complete all as specified and directed |
| 111 | Taking down ofunserviceablesub main wiring of any size complete all as specified and directed |
| 112 | Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable(ISI marked) 1100 volts grade FRLSH with multistranded copper conductor, drawn through concealed / surface in wall / roof/ceiling surface and its accessories on the surface etc including PVC rigid medium grade concealed conduit of suitable size with all accessories such as bend, reducers, MS hooks including modular galvanisedflush boxes of suitable size and white cover plate with frame as per relevant ISfor mounting modular switches, sockets, fan regulators etc including continuous earth wire of size 1.5 Sqmm PVC FRLSH stranded copper conductor unsheathed, insulated, strandedconnected to common earthpoint dolly for one light point/fan point/call bell point, 230 voltscontrolled by one switch complete all as specified and directed . Note:- Proper colour coding is to be followed as per IS specifications. |
| 113 | All as per Srl item No 112.here-in-before but for onesocket outlet, 3 Pin 5 Amps, 230 Volts on independent board complete all as specified and directed |
| 114 | All as per Srl item No.112here-in-before but for one three pin socket outlet 5 Amp on the same board with other switches complete all as specified and directed |
| 115 | All as per Srl item No 112 here-in-before but for one 3 pin socket outlet 16 Amp independent with cable of size 2.5 Sqmm for point wiring and 2.5 sqmm as in continuous earth wire complete all as specified and directed |
| 116 | S&F modular type switch, one way 6 Amps , 1 module complete all as specifieds and directed . |
| 117 | S&Fmodular type socket 3 pin, 6 Amps, 2 module complete all as specifieds and directed . |
| 118 | S&F modular type switch, one way, 16 Amps, 1 module complete all as specifieds and directed . |
| 119 | S&Fmodular type socket 3 pin, 6 A/16 Amps,2 module complete all as specifieds and directed . |
| 120 | S&F ceiling rose, surface backelite,two/three terminal, 240 volts complete all as specifieds and directed . |
| 121 | S&F LED lightfitting 1x18Watt, 220V, Integrated batten type with driver, holder including LED tube light, connecting up with three core flexible copper conductor cable of suitable size from ceiling rosewith all fixing arrengenmentcomplete all as specifieds and directed .. |
| 122 | S&F energy saving new generation 10W LED bulk head luminaire with opal diffuser, IP 65 and including connecting up with twin core twisted flexible copper coductor cable with suitable size of 230 volt,50 Hz complete all as specified and directed. |
| 123 | S&FSheet metal enclosure for DBs,SPN, double door,IP-43 protected, 415 Volts,8 ways with 100 amps rated copper bus bar complete all as specified and directed |
| 124 | S&F MCB SPN, 32 Amp, 240 Volts withrupturing capacity 10 KA, \"C\" series, complete all as specifieds and directed . |
| 125 | S&F MCB Single pole, 6 to 32 Amp, 240 Volts withrupturing capacity 10 KA, \"C\" series, complete all as specifieds and directed . |
| 126 | S&FSubmain wiring with two runs of single core PVC FRLSH unsheathed, insulated, copper cable of 6 Sqmm size, multi stranded, 1100 volts grade with PVC insulated,unsheathedFRLSH copper wire 6 Sqmm for continous earth wire drawn into and includingconcealed PVC conduit of suitable sizecomplete all as specifiedand directed . Note :- Two runs of 6 Sqmm copper cable and one run of 6 sqmm copper wire earth continuty conductor in conduit with accessories shall be measured as one length) |
| 127 | Taking down existing ceiling fan of any size/sweep including oiling, greasing, cleaningand applying two coats of synthetic enamel paint after preparation of surface and refixingthe same complete all as specified and directed . |
| 128 | S&Fexhaust fan, steel body, AC single phase. 230 V of size 300 mm sweep with, blades and frame and louvers, hanging on wall with 4 Nos steel fasterners 10mm dia & 100mm long includingwall hole and making good the disturbed surfaces as per existingcomplete allas specified & directed |
| 129 | S&FSheet metal enclosure for DBs,TPN, double door,IP-43 protected, 415 Volts,4 ways with 100 amps rated copper bus bar complete all as specified and directed |
| 130 | S&F MCB four pole, 40 to 100 Amp, 415 Volts withrupturing capacity 10 KA, \"C\" series, complete all as specifieds and directed . |
| 131 | M&L for complete earthingwith galvanised mild steel earth plate electrode of size600x600x6mm thick, burried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC 1:2:4 type B-1, precast RCC cover slab using reinfocement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12mm round bar including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh ,15mm dialight grade galvanised steel tubing upto 7.5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specifieds and directed .. |
| 132 | Supply, laying, jointing, testing and commissioning of Low Tension (LT)XLPEinsulated, armoured, heavy duty, electric power cable, cross sectional area 25 Sqmm, 4 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, alongpolesorpassing through pipes or laid under floor or through walls etc, complete including taking out old cable & bricks all as specified anddirected. Note:(i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately. |
| 133 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth in any type ofsoilfor laying of cables, pipes etc. and getting out complete all as specified and directed . |
| 134 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified and as directed. |
| 135 | Removing excavated material or surplus soil to a distance not exc 50 meter and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed . |
| 136 | M&L for sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment. |
| 137 | M&L for factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dryin trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed. |
| 138 | S&F Galvanised steeI tubing, light grade, 40mm bore, for cable protection, fixed to pole/wall with MS clamps, nuts, bolts etc or laid under floor/road/pavementcomplete all as specified and directed. |
| 139 | Disconnecting, dismantling and taking down carefully ACSR conductor ofany size fromLT/HTpoles complete all as specified and directed.. |
| 140 | Dismantling and taking down old cross arms, clamps, braces, brackets of MS channel or angle section including nut boltswashers etc from poles complete all as specified and directed. |
| 141 | Dimantlingand taking down old Insulators of any types complete all as specified and directied. |
| 142 | Supply, laying, jointing, testing and commissioning of Low Tension (LT)XLPEinsulated,armoured, heavy duty, electric power cable, cross sectional area 10 Sqmm, 2.0 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, alongpolesorpassing through pipes or laid under floor or through walls etc, completeall as specified and as directed. Note:(i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately. |
| 143 | Supply, laying, jointing, testing and commissioning of Low Tension (LT)XLPEinsulated,armoured, heavy duty, electric power cable, cross sectional area 16 Sqmm, 2.0 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, alongpolesorpassing through pipes or laid under floor or through walls etc, completeall as specified and as directed. Note:(i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately. |
| 144 | Supply, laying, jointing, testing and commissioning of Low Tension (LT)XLPEinsulated,armoured, heavy duty, electric power cable, cross sectional area 25 Sqmm, 4.0 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, alongpolesorpassing through pipes or laid under floor or through walls etc, completeall as specified and as directed. Note:(i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately. |
| 145 | Supply, laying, jointing, testing and commissioning of Low Tension (LT)XLPEinsulated,armoured, heavy duty, electric power cable, cross sectional area 70 Sqmm, 3.5 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, alongpolesorpassing through pipes or laid under floor or through walls etc, completeall as specified and as directed. Note:(i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately. |
| 146 | Supply, laying, jointing, testing and commissioning of Low Tension (LT)XLPEinsulated,armoured, heavy duty, electric power cable, cross sectional area 185 Sqmm, 3.5 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, alongpolesorpassing through pipes or laid under floor or through walls etc, completeall as specified and as directed. Note:(i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately. |
| 147 | Supply, laying, jointing, testing and commissioning of Low Tension (LT)XLPEinsulated,armoured, heavy duty, electric power cable, cross sectional area 50 Sqmm, 3.5 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, alongpolesorpassing through pipes or laid under floor or through walls etc, completeall as specified and as directed. Note:(i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately. |
| 148 | Supply, laying, jointing, testing and commissioning of Low Tension (LT)XLPEinsulated,armoured, heavy duty, electric power cable, cross sectional area 95 Sqmm, 3.5 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, alongpolesorpassing through pipes or laid under floor or through walls etc, completeall as specified and as directed. Note:(i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately. |
| 149 | S&F Galvanised steeI tubing, light grade, 80mm bore, for cable protection, fixed to pole/wall with MS clamps, nuts, bolts etc or laid under floor/road/pavementcomplete all as specified and directed. |
| 150 | M&L for factory made bus bar chamber of size 750 x 600 x 500 mm, outdoor type, pedestal type, powder coated, made out of 3.15 mm thick CRCA sheet duly powder coated, dust and vermin proof complete with openable shutter in front & rear having proper locking arrangement duly mounted on angle iron frame 50x50x6 mm including necessary earth work & PCC in foundationin all respect including400 Amp, 415 Volt,36 KA, 4 pole MCCB withthermal magnetic protection as incommer control and aluminium bus bar mounted on insulator, 500 Amps, 4 pole, suitable for 3 phase, 415 volts, 50 Hz AC supply including control wiring to panel with suitable size of PVC insulated and sheathed copper cablewith phase indicator lamps (R, Y. B) – 01 Set. complete all as specified and directed. |
| 151 | M&L for factory made bus bar chamber of size 750 x 600 x 500 mm, outdoor type, pedestal type, powder coated, made out of 3.15 mm thick CRCA sheet duly powder coated, dust and vermin proof complete with openable shutter in front & rear having proper locking arrangement duly mounted on angle iron frame 50x50x6 mm including necessary earth work & PCC in foundationin all respect including100 Amp, 415 Volt,36 KA, 4 pole MCCB withthermal magnetic protection as incommer control and aluminium bus bar mounted on insulator, 500 Amps, 4 pole, suitable for 3 phase, 415 volts, 50 Hz AC supply including control wiring to panel with suitable size of PVC insulated and sheathed copper cablewith phase indicator lamps (R, Y. B) – 01 Set. complete all as specified and directed. |
| 152 | M&L for factory made bus bar chamber of size 750 x 600 x 500 mm, outdoor type, pedestal type, powder coated, made out of 3.15 mm thick CRCA sheet duly powder coated, dust and vermin proof complete with openable shutter in front & rear having proper locking arrangement duly mounted on angle iron frame 50x50x6 mm including necessary earth work & PCC in foundationin all respect including250 Amp, 415 Volt,36 KA, 4 pole MCCB withthermal magnetic protection as incommer control and aluminium bus bar mounted on insulator, 400 Amps, 4 pole, suitable for 3 phase, 415 volts, 50 Hz AC supply including control wiring to panel with suitable size of PVC insulated and sheathed copper cablewith phase indicator lamps (R, Y. B) – 01 Set. complete all as specified and directed. |
| 153 | M&L for factory made bus bar chamber of size 750 x 600 x 500 mm, outdoor type, pedestal type, powder coated, made out of 3.15 mm thick CRCA sheet duly powder coated, dust and vermin proof complete with openable shutter in front & rear having proper locking arrangement duly mounted on angle iron frame 50x50x6 mm including necessary earth work & PCC in foundationin all respect includingaluminium bus bar mounted on insulator, 600 Amps, 4 pole, suitable for 3 phasex1 neutral, 415 volts, 50 Hz AC supply including control wiring to panel with suitable size of PVC insulated and sheathed copper cablewith phase indicator lamps (R, Y. B) – 01 Set. complete all as specified and directed. |
| 154 | M&L for factory made bus bar chamber of size 750 x 600 x 500 mm, outdoor type, pedestal type, powder coated, made out of 3.15 mm thick CRCA sheet duly powder coated, dust and vermin proof complete with openable shutter in front & rear having proper locking arrangement duly mounted on angle iron frame 50x50x6 mm including necessary earth work & PCC in foundationin all respect includingaluminium bus bar mounted on insulator, 200 Amps, 4 pole, suitable for 3 phasex1 neutral, 415 volts, 50 Hz AC supply including control wiring to panel with suitable size of PVC insulated and sheathed copper cablewith phase indicator lamps (R, Y. B) – 01 Set. complete all as specified and directed. |
| 155 | S&F thermoplastic polystyrene polycarbonate junction box of size 210 X 155X 92 mm, shock proof with IP 66 protectionwith suitable connector for three phase loop in loop out branch out and vibration proof connection and fixing on LT/HTpoles using MS clamp made out of 25mm x 3mm MS flat (02 Nos) and nuts & bolts of required size complete all as specified and directed |
| 156 | M&L in repairfor complete earthingwith galvanised mild steel earth plate electrode of size600x600x6mm thick, burried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the earth plate not less than 1.5 mtr below ground level connected to GI strip 25x4mm by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC 1:2:4 type B-1, precast RCC cover slab using reinfocement with XPM weighing not less than 4.00 kg/Sqm with suitable handle made of 12mm round bar including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh ,40mm diamedium grade galvanised steel tubing upto 7.5 m length for drawing earth strip protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and directed. |
| 157 | M&L for cutting of bituminous road / floor for laying of pipe / cables, not exceeding 1.5 meter wide and not exceeding 1.5meter deep including refilling the material ,watering, well ramming / compacting and making good with 100 mm thick PCC 1:2:4,type B-1 complete all as specified and directed. |
| 158 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium solid conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sqmm 2 corenominal cross section in service connection complete all as specified and directed. |
| 159 | S&FSubmain wiring with two runs of single core PVC FRLSH unsheathed, insulated, copper cable of 2.5 Sqmm size, multi stranded, 1100 volts grade with PVC insulated,unsheathedFRLSH copper wire 2.5 Sqmm for continous earth wire drawn into and includingconcealed PVC conduit of suitable sizecomplete all as specifiedand directed . Note :- Two runs of 2.5 Sqmm copper cable and one run of 2.5 sqmm copper wire earth continuty conductor in conduit with accessories shall be measured as one length) |
| 160 | S&FSheet metal enclosure for DBs,SPN, single door,IP-43 protected, 240 Volts,2 wayscomplete all as specified and directed |
| 161 | S&F electric water heater of capacity 25 litres,BEE 5 Star rated,storage type, steel body vertical type with glass lined /porcelain enamel coated steel inner tank and glass line double ceramic heating element upto 2 KW complete with all accessories such as safety valve,thermostate NRV,connection piece etc and fixing with 04 Nos nut bolt grouting in wall in PCC(1:2:4) using 12.5mm graded stone aggregate for hanging the geyser and making good the disturbed surface complete all as specified and directed |
| 162 | S&F pillar taps, chromium plated, fancy type, cast copper alloy with capstan heads, screwed down high pressure with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly nuts screwed for iron pipe of 15mm bore complete all as specified and directed. |
| 163 | S&F Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe of 15mm bore or for unions and fixed complete all as specified and directed. |
| 164 | Supply, laying, jointing, testing and commissioning of Low Tension (LT)XLPEinsulated,armoured, heavy duty, electric power cable, cross sectional area 240 Sqmm, 3.5 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, alongpolesorpassing through pipes or laid under floor or through walls etc, completeall as specified and as directed. Note:(i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately. |