| 1 | M&L for surface excavation not exc. 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed. |
| 2 | Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying of cables, etc. not exc.10 sqm on plan and not exc. 1.5m in depth and getting out soft/loose soil complete all as specified and as directed. |
| 3 | M&L for hardcore of gauge not exc. 63mm of broken stone boulders, deposited, spread and levelled in layers not exc. 15cm thick, watered, levelled and well rammed to a true surface complete all as specified and as directed. |
| 4 | M&L for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete, etc. complete all as specified and as directed. |
| 5 | M&L for PCC (1:2:4) type B-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete, etc. complete all as specified and as directed. |
| 6 | Use & waste formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete (square, rectangular or polygonal) complete all as specified and as directed. |
| 7 | S&F for hold fasts, fastener, bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required:hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed. |
| 8 | S&F structural steel work in hollow tubular section (RHS or SHS) including special shaped washer, etc. complete using ERW or induction butt welded tubes as in purlin, rafter, posts, etc. confirming to IS : 4923 grade Yst 310 complete all as specified and as directed. |
| 9 | M&L for preparation of new steel surfaces of any description over exc. 10cm girth or width and applying two coats of synthetic enamel paint over and including one coat of red oxide primer complete all as specified and as directed. |
| 10 | M&L for brickwork (old size) with sub class ‘B’ bricks, straight or curved on plan, exc. 6m mean radius, built in cement mortar (1:6) complete all as specified and as directed. |
| 11 | M&L for 15mm thick rendering on fair faces of brick work or concrete surface of walls in cement mortar (1:4), finished even and smooth without using extra cement complete all as specified and as directed. |
| 12 | M&L for 15mm thick rendering on fair faces of brick work or concrete surface of walls in cement mortar (1:6), finished even and smooth without using extra cement complete all as specified and as directed. |
| 13 | M&L for preperation of new surfaces of walls andapplying two coats of oil bound distemper over and including one coat of alkali resistant primer complete all as specified and as directed. |
| 14 | M&L for preperation of new surfaces of walls and applying two coats of cement base paint over and including one coat of alkali resistant primer complete all as specified and as directed. |
| 15 | M&L for removing of excavated soil/material exc. 250m but not exc. 500m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and as directed. |
| 16 | S&F pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, etc. fixed with self tapping screws complete all as specified and as directed. |
| 17 | S&F pre-painted galvalume aluminium zinc coated GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, etc., fixed with self tapping screw complete all as specified and as directed. |
| 18 | M&L for MS flat iron as wind ties for roof including, securing bolts cutting tops to shape as directed drilling holes including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 19 | S&F for powder coated aluminium window and ventilator glazed/gauged shutters sliding type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittingscomplete all as specified and as directed. |
| 20 | S&F powder coated anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws, etc. complete all as specified and as directed. |
| 21 | S&F for powder coated aluminium anodised frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed. |
| 22 | M&L for providing cement concrete type B-0 (1:2:4) (using 12.50mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed. |
| 23 | Cutting holes in brick walls in cement mortar for inserting holdfasts and making good to dismantled portion in cement mortar (1:3) or cement concrete (1:2:4) Type B-1 as required depth of embedded portion of holdfasts exc. half brick but not exc. one brick thick complete all as specified and as directed. |
| 24 | M&Lfor vitrified coloured tiles, 10mm thick (square/rectangular), area of each tile not exceeding 0.36 sqm,fixed as on floors, etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed. |
| 25 | M&L for glazed ceramic coloured tiles of size 450x300x6/7mm thick, fixed as on vertical surfaces, set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick screed bed/bedding in cement mortar (1:4) complete all as specified and as directed. |
| 26 | S&F false ceiling with aluminium anodised snap grid of size 605x605mm to support the boards/tiles including proper hanging arrangement with anodised galvanised iron wire and adjuster complete all as specified and as directed. |
| 27 | M&L for 6mm thick high pressure steam cured non asbestos fibre cement designer ceiling board of size to suit grid mould (605x605mm as specified above) and fixed in grid mould with necessary fixing arrangement as per manufacturer\"s instructioncomplete all as specified and as directed. |
| 28 | S&F plates/base plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes without any attachment or gusset plate conforming to Fe-410-W (Gde-E-250) quality-B complete all as specified and as directed. |
| 29 | S&F mild steel bolts (machine made) with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc. 15cm but not exc. 22.50cm (dia of neck 11 to 15mm) complete all as specified and as directed. |
| 30 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished surfaces of concrete complete all as specified and as directed. |
| 31 | S&F PVC (SWR) half round gutters drain pipe of size 180mm bore complete all as specified and as directed. |
| 32 | S&F PVC (SWR) joint socket as in gutters drain pipe of size 180mm bore complete all as specified and as directed. |
| 33 | S&F PVC (SWR) joint tee with end cap as in gutters drain pipe of size 180mm bore complete all as specified and as directed. |
| 34 | S&F PVC (SWR) pipe single socketed in any length, fixed to wall of size 110mm bore with rubber ring joint complete all as specified and as directed. |
| 35 | S&F PVC (SWR) bends of size 110mm bore (any radius) complete all as specified and as directed. |
| 36 | S&F rolled mild steel of Fe 410-W (Gde-E- 250) quality-A in stairs (framed) including stringers, treades, landing, balusters, hand rails, etc. including cleats, brackets, etc. complete all as specified and as directed. |
| 37 | M&L for PCC M-10 (1:3:6) (Nominal mix, using 20mm graded stone aggregate) as in foundation, filling and mass concrete, etc. complete all as specified and as directed. |
| 38 | M&L for PCC M-15 (1:2:4) (Nominal mix, using 20mm graded stone aggregate) as in foundation, filling and mass concrete, etc.complete all as specified and as directed. |
| 39 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 40 | Taking down chowkhat or frame with shutter (without taking off shutters from the frame) area not exc. 1.5 sqm each and removing item from site complete all as specified and as directed. |
| 41 | All as per Serial item No. 40 here-in-before but area exc. 1.5 sqm but not exc. 4 sqm each. |
| 42 | Dismantling timber scantling 40 sq.cm and over in section, in any position, in unframed work complete all as specified and as directed. |
| 43 | Dismantling timber fillets, rails, posts, rafters, purlins, etc. under 40 sq.cm in section as in any position, in unframed work complete all as specified and as directed. |
| 44 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed. |
| 45 | Demolition of brick work built in cement mortar complete all as specified and as directed. |
| 46 | Demolition of unreinforced cement concrete in ground floors and pavings not exc. 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 47 | Supply and installation hi wall split units (indoor & outdoor) AC with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 5.0.of capacity 1.5 TR with sufficient length of copper pipe including shed for outdoor unit complete all as specified and as directed. |
| 48 | S&F voltage stabilizer for automatic operation, single phase, naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage stabilzed at 230 volt with accuracy of +2.5% and of capacity 4.0 KVA complete all as specified and as directed. |
| 49 | M&L for submain wiring with two run single core 4 sq.mm FRLS PVC insulated copper cable 1100 vots grade multistrand, un-sheathed conductor, drawn into PVC casing and caping alongwith all necessary fittings including 4 sq.mm multi strand FRLS PVC insulated copper wire for earth continuty conductor connected to common earth dolly and making good disturbed surfaces complete all as specified and as directed. |
| 50 | S&F single pole and neutral (SPN) enclosure with a two pin and earth plug and socket with one single pole MCB 20 Amps, 240 volt AC and electrically connecting up complete all as specified and as directed. |
| 51 | S&F for MCB single pole, 240 volts, 6 - 32 Amps, 10 KA, \"C\" curve complete all as specified and as directed. |
| 52 | M&L for point wiring with 1.5 sq.mm of FRLS grade PVC insulated and unsheathed stranded copper conductor cable, 1100 volts grade as per IS-694 drawn through and including PVC cassing and capping (not less than 20mm wide) /conduit complete with all acessoriesincluding PVC board/ box of suitable size for mounting of switches, sockets, regulators, etc. including 1.5 sq.mm stranded copper conductor cable FRLS grade PVC insulated and unsheathed as earth continuity conductor, fabricated steel sunken terminal box duly painted made out of 1.60mm thick MS sheet concealed in walls with 3mm thick/bakelite/PVC sheet ISI marked top cover with brass/chromium plated screws and cup washers for housing switches, socket outlets, fan regulators, etc. for one LED tube light/LED lamp/ building security light point controlled by one way switch complete all as specified and as directed. |
| 53 | All as per Serial item No. 45 here-in-before but for one ceiling / exhaust fan point controlled by one, one way switch. |
| 54 | All as per Serial item No. 45 here-in-before but for 5 amps socket point on independent board. |
| 55 | All as per Serial item No. 45 here-in-before but with 2.5 sq.mm cable for 15 amps socket outlet on independent board, using 2.5 sq.mm earth continuity conductor. |
| 56 | S&F ceiling rose surface backelite three terminals, PVC / polycarbonate insulated body complete all as specified and as directed. |
| 57 | S&F switch piano modular type, 6 Amps 240 volts single pole one way complete all as specified and as directed. |
| 58 | S&F socket outlet, 5 pin 6 Amps, modular type complete all as specified and as directed. |
| 59 | S&F socket outlet 15/16 Amps, 6 in 1, modular type complete all as specified and as directed. |
| 60 | S&F switch piano modular type,15/16 Amps 240 volts single pole one way complete all as specified and as directed. |
| 61 | S&F modular plates with frame (white colour) 4 module complete all as specified and as directed. |
| 62 | S&F modular plates with frame (white colour) 6 module complete all as specified and as directed. |
| 63 | S&F modular plates with frame (white colour) 8 module complete all as specified and as directed. |
| 64 | S&F LED light fitting 1x20 watt decorative box type with driver holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 65 | S&F LED light fitting 1x20 watt decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 66 | S&F wall mounted fan of size 400mm sweep, AC single phase, 230 volts with blades, frame and providing connection with and including 3 core flexible copper conductor cable of suitable size and length including taking down and depositing the same into MES store yard complete all as specified and as directed. |
| 67 | S&F sheet metal enclosure TPN DB, 4 ways double door having facility to fix MCB in incommer and MCBs in outgoing, IP-43 type complete fitted with bus bars, neutral links, blanking plates complete all as specified and as directed. |
| 68 | S&F MCB 415 volts, 10 KA, \"C\" curve miniature circuit breaker (MCB) of TPN 40 to 100 amps and current carrying capacity in the DB with connection testing and commissioning complete all as specified and as directed. |
| 69 | S&F MCB single pole & neutral 240 volts, 32 Amps, \"C\" curve in the MCB, DB with connection includingtestingcomplete all as specified and as directed. |
| 70 | M&L for submain wiring with two runs of single core 6 sq.mm FRLS PVC insulated copper cable 1100 vots grade multistrand, unsheathed conductor drawn into PVC casing and capping and all necessary fittings including 1x4 sq.mm multi strand FRLS PVC insulated copper wire for earth continuty conductor connected to common earth dolly complete all as specified and as directed.Notes : (a) Extra length of cables/ wire required for connection to MCBs/DBs shall not be measured and the rate quoted by the contractor for per unit shall be deemed accordingly.(b) Cuttings/ chasing of wall etc. and making good to the disturbed surface shall be measured and paid seperately. |
| 71 | Excavation in trenches over area not exc. 1.5m deep and getting out in soft/loose soil complete all as specified and as directed. |
| 72 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 250mm in soft/loose soil complete all as specified and as directed. |
| 73 | M&L for removing of excavated material (soil)not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and as directed. |
| 74 | M&L for sand cushioning (dry) in trenches for protection of UG cables (below, above and around the UG cable laid in trenches) of 230mm spread thickness and consolidated (punned) upto 160mm thickness complete all as specified and as directed. Note: For the purpose of payment, punned thickness of sand cushioning only shall be measured and paid. |
| 75 | S&F sub-class \"B\" bricks, well burnt, laid breadth-wise along the length of cable laid in trenches over sand cushion laid for UG cable protection complete all as specified and as directed. |
| 76 | M&L for cable in trenches/passing through pipe/on wall, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade of cross sectional area 16 sq.mm, 4 core complete all as specified and as directed.Note: Rate of the saddle and clamp for fixing of cable on wall is deemed to be included with the quoted rate. |
| 77 | S&F voltage stabilizer of capacity 10 KVA for automatic operation, three phase, naturally oil cooled indoor type and designed for input variation between 340 to 460 volts with output voltage stabilzed at 4150 volt with accuracy of +2.5% and speed of correction 8 Volts per second complete all as specified and as directed. |
| 78 | S&F air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified and as directed. |
| 79 | S&F thermoplastic weather proof empty box (IP-65) with plane wall of adequate size , fixed on wall with provision of nuts, bolts, washer, etc. including fixing of test point terminal block inside the box made out of gun metal or phosphorous bronze of size 75x75x25mm, drilled and screwed including 3 Nos 8mm dia, 25mm long hexagonal head screw and including taking down old unserviceable one complete all as specified and as directed. |
| 80 | S&F for50mm high density polyethylene pipe (HDPE) of pressure rating 6 kgf/Sqcm with all fittings, laid in trench or fixed in wall for protection of earth strip complete all as specified and as directed. |
| 81 | S&F 20mmx3mm copper strip as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing,etc. complete all as specified and as directed. |
| 82 | M&L for copper/brass nuts, bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exc. 5cm long and diameter of neck 5mm to 10mm for connection of earthing strip including making necessary hole of required diameter complete all as specified and as directed. |
| 83 | S&F tripale pole and neutral enclosure with a 5 pin and earth plug and industrial female socket complete with one TNP 20/25 amps, 415 volt, AC MCB complete all as specified and asdirected. |
| 84 | M&L for earthing with copper earth plate electrode of size 600x600x3mm thick buried directly in ground vertically to a depth of not less than 2.25m below ground level, connected to copper strip of size 20x3mm as earthing lead means of nut, bolts and washers, made out of copper/brass and 32mm dia GI pipe \"medium grade\" for protection of earth lead and connected to test point or as directed including PCC pit in cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) and RCC cover of size 450x450x50mm in RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) reinforced with and including 8mm dia TMT bars @100mm centre to centre both ways, galvanised iron wiremesh, funnel, galvanised iron watering pipe 20mm bore \"medium grade\", including necessary excavation and earth work in soft/loose soil complete, returning, filling in and removal of surplus soil upto a distance of 50m all as shown in Electrical Plate No. 5 of MES Schedule Part-I and testing on completion including taking down old existing unserviceable earthing complete all as specified and as directed. Note : Copper strip upto 7.5m including testing is deemed included in the item. |
| 85 | M&L for chemical earthing electrode advance encapsulated compound based CPRI tested maintanance free pipe-in-pipe technology upgraded (Zinc & Alloy Coated), zinc coated (80-100) microns with pure zinc (99.9%) and alloy coating (200-250) microns, earthing system confirming IS 3034. The outer & inner pipe should be 76.2mm& 41.9mm dia (dimention may vary + 1mm) , 3M length,zinc coated with additional special alloy coating 300mm on the topside for additional corrosion protection of the terminal. The annular space between the pipes being filled up with COMPACT FILL (CF) (crystalline conductive compound). The compact fill (CF) misture which is machine pressed in the pipes should not disintegrate or collapse when outer pipe corrodes. The inner pipe should be extended with terminals for connectivity, the job includes digging the pits and refilling the same by electrodite/conductolite back fill compound (Ground Enhancer), the BFC should be eco friendly, it should not contain enviromentally hazardous material/metal having RoHS certification from NABL Accredited Lab. Good earth is to be arranged to fill the excavated pits by mixing the same with BFC 3 bags (25 KG each) including PCC pit in cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) and RCC cover of size 450x450x50mm in RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) reinforced with and including 8.0mm dia TMT bars @ 100mm centre to centre both ways including taking down old existing unserviceable earthing complete all as specified and as directed. |
| 86 | S&F 10 KVA online UPS 01 Nos. along with 26 AH 12V SMF battery : 16 Nos. and battery rack & interlinks, input power factor corrector 0.99 PFC, automatic bypass, single phase input and output with inbuilt isolation transformer and having inbuilt manual bypass in 6 & 10 KVA complete all as specified and as directed. |
| 87 | S&F powder fire extinguisher (store pressure type) capacity 02 Kg dult ISI marked conforming to IS-15683:2018 with IS 4308, ISI marked ABC powder complete with squeeze grip release valve, locking arrangement, pressure gauge, operation manual and bracket. Operating temperature : -30C + 3060c including fixing the same in wall etc. complete all as specified and as directed. |
| 88 | S&F LED aviation light luminaries comprising of alluminium housing with polycarbonate encloser with 302 Nos LED including cable for connection after and including taking down old unserviceable light fittings complete all as specified and asdirected. Make : Bajaj, Cat No. BGAV302 LED or equivalent model of make specified in Particular Specifications.NOTE:- The contract sum shall be derieved by deducting the amount shown in chedule of Credit attached to this tender from total amount of Schedule \"A\"/BOQ. |