| 1 | Material & labour for brick work with fly ash bricks in CM 1:6 brickstraight or curved on plain exeeding 6m mean radius complete all as specified & directed. |
| 2 | Material & labour for 15 mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces, surfacesfinished even and smooth without using extra cement complete all as specified and directed. |
| 3 | Material & labour for preparation of new plastered surfaces of walls with wall care putty and applying two coats of Oil bound distemper to match the existing surfaces as required, complete all as specified & directed. |
| 4 | Use & waste of form work to sides and soffits of beams lintels etc finishedroughcomplete all as specified and directed. |
| 5 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 6 | M&L for mild steel TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required as in stirrups complete all as specified and directed. |
| 7 | M & L for RCC 1:2:4 Type B1 using 20 mm graded stone aggregate as in beams, lintels over 1.5 m span etc complete all as specified and directed. |
| 8 | Supply and fix 30 mm thick flush shutter solid core construction with particle board and plywood face panels commercial type on both side complete all as specified and directed |
| 9 | Supply & fixing pressed steel frames for doors with one or more rebates including necessary fixing lugs lugs, hinges, lock strike plates etc completed size of frame 125x60mm made out of 1.25mm MS sheets complete including fitting PCC 1:3:6 type C-O using 12.5 mm graded store aggregated all as specified & directed. |
| 10 | S &F MS Flat iron 25mm x 6mm as in hold fast welded to angle iron door frame as directed by Engr-in-Charge. |
| 11 | Supply & fix 125mm size aluminium alloy handles cast type anodized complete all as specified & directed. |
| 12 | S&F aluminium tower bolts 150mm long, of extruded section complete all as specified and directed. . |
| 13 | Supply & fix Aluminium sliding door bolts, plate type,complete, 250mm long complete all as specified and directed. |
| 14 | M&L for preparation of new or previously untreated wooden surfaces of any description, not other wise described over 10cm width or girth and apply two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 15 | M&L for preparation of new or previously untreated steel surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 16 | M&L for MS work as in angle iron fencing posts & strutsthick for Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors,balusters,nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to IS-15911-2010. completted all as specified and directed. |
| 17 | S &F for Rolled sections of Fe 410W (Gde 250 ) quality A as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates. completted all as specified and directed |
| 18 | Supply and fix Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpaas in roof covering/cladding to wall,fixed with self tapping screws as specified.complete all as specified and directed. |
| 19 | Surface excavation n.exc. 30cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as directed. |
| 20 | Excavation in trenches not exc. 1.5 metre wide and not exc. 1.50 metre in depth for foundation , laying cable/pipefor manholes etc n.exc. 10 Sqm on plan and n.exc. 1.5 metre depth and getting out in soft/loose soil complete all as directed. |
| 21 | Removing excavated materials (soils) to a distance not exc. 50 metre and depositing where directed at a level not exc. 1.50 above the starting point complete all as directed. |
| 22 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick as in soft/loose soil complete all as directed. |
| 23 | Approved soil filling under the floor, spreading and levelling in layers n.exc. 25cm thick, well ramming including watering as required complete all as specified and directed. |
| 24 | Material & labour for hardcore of broken bricks gauges n.exc. 63mm, deposited spread and leveled in layers n.exc. 15 cm thick watered and rammed to a true surface complete all as specified and directed. |
| 25 | Material & labour for plain cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete and sub base of floor complete all as specified and directed. |
| 26 | Use and waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter |
| 27 | Use and waste ofForm work of sides of pillars, posts, struts, piers, columns etcsquare or rectangular or polygonal rough surfaces of concrete |
| 28 | Use & waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick flat fair finished surfaces of concrete. |
| 29 | Use & waste ofform work to the edge of concrete flat n. exc 200 mm thick . |
| 30 | M&L for RCC 1:2:4 Tybe B1 using 20 mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete. complete all as specified and directed |
| 31 | M & L for RCC 1:2:4 Type B1 using 20 mm graded stone aggregate as in Columns, pillars etc. complete all as specified and directed. |
| 32 | M&L for RCC 1:1:5:3 type A-1 using 20 mm graded stone aggregate for roof slabs supported on walls, beams and the like Complete all as specified and directed. |
| 33 | Material & labour for 15 mm thickrendering on other than fair faces of brick work or concrete surfaces inCM 1:4, surface finished even and smooth without using extra cement complete all as specified and directed. |
| 34 | Material & labour for 5 mm thick plaster in CM 1:3 on ceiling surfaces, surfacesfinished even and smooth without using extra cement complete all as specified and directed. |
| 35 | M&L for 75 mm thick plain cement concrete 1:3:6 type C-2 using (40 mm graded stone aggregate) as in sub base for floor all as specified and directed. |
| 36 | M&L for Non Skid ceramic tiles10 mm thick (squares/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm, (400 x 400 x 10mm) in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement joint free non skid tiles.to match 15mm thick screed bed in CM 1:6 complete all as specified and directed |
| 37 | Material & labour for glazed coloured ceramic tiles of size450x300x7-8mm thick,on vertical surfaces set and jointed in neat cement slurry and pointed in white/ coloured cement to match with existing work over and including 10mm thick rendering in CM 1:4 complete all as specified & directed. |
| 38 | M&L for 75 mm thick PCC 1:3:6Type C-2 using 40mm graded stone aggregate as in plinth protection etc, laid to slope of 1:12 and shall be laid in alternate bays n.exc 1.5 m in length, joints 20mm wide will be provided every 1.5m and filled with ceiling compound grade ‘A’ the joints between external wall and plinth protection shall also be laid with ceiling compound grade ’A’, finishedcement concrete surface even and smooth all as specified & directed. |
| 39 | Material & labour for preparation of new plastered surfaces of walls etcand applying two coats of cement base paint over a coat of primercomplete all as specified & directed. |
| 40 | Material and labour for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified & directed. |
| 41 | Material & labour for cleaning of plastered /concrete surfaces and applying priming coat using bituminous primer @ 0.30 Kg/Sqm. followed by evenly a tack coat @ 1.20 Kg/Sqm. using with 85/25 grade bitumen, over laid with 3mm thick APP modified polymeric water proofing membrane with non woven polyester reinforced of weight not less than 3.6 Kg/Sqm. unrolled and bonded to substance with side and end laps 75mm and 100mm as per manufacturer’s instructions and finished top of APP water proofing polymeric membrane with a coat of hot blown industrial bitumen 85/25 grade @ 1.20 Kg/Sqm and finally finished with a coat of bituminous aluminium paint @ 0.20 Kg/Sqm complete all as specified and directed. |
| 42 | S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing |
| 43 | Supply & fix factory made solid panel PVC door shutter 30mm thick (style) consisting of frame, made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC , ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for to rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed to getter with solvent cement, supplying & fixing in the frame at site as per specification & drawing. complete all as specified and directed. |
| 44 | Supply and fixing PVC waste pipes of 40/32mm bore suitable for wash hand basins/sinks complete all as specified & directed. |
| 45 | Supply & fixing steel C.P. grating 100/125 mm dia as reqd at site complete all as directed by Engineer-in-Charge. |
| 46 | S&F for 110 mm bore PVCfloor traps plain with grating and 300 mm long out let including jointing with cement concrete type B -1 1:2:4 complete all as specified & directed. |
| 47 | Supply and fix PVC (SWR)bends 110mm bore, any radius complete all as specified & directed. |
| 48 | Supply & fix steel windows or ventilators fixed type, complete all as specified & directed. |
| 49 | Supply & fix mild steel framed work such as grills, gratings guard bar etc with ends of bars shouldered and/ or riveted etc completed all as specified & directed. |
| 50 | S&FGun -metal,globe or gate valves 15mm bore with iron wheel head ,screwed both ends for iron pipe and fixed. |
| 51 | Supply & fixbib taps cast copper alloychromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe of 15mm bore, complete all as specified & directed. |
| 52 | Supply & fix invitreous china wash hand basin, white, flat back of size 550x400mm (excluding taps, waste chain and plug and porcelain stopper) but including brackets suitable for 15mm dia pipe complete all as specified & directed. |
| 53 | Supply & fix angle valve, 15 mm bore, cast copper alloy, chromium plated, fancy type with long shank and cup, screwed down, high pressure screwed both ends for iron pipes or for unions and fixed in pipe complete all as specified & directed. |
| 54 | Supply & fix rotational moulded polyethylene water storage tanks 500 liters capacity double layer, (cylindrical, vertical in closed top) hoisted and fixed in position with all fittings all as specified directed. |
| 55 | Supply & fix inPVC low level flushing cistern of 9-10 ltrs capacity, ISI Marked, white, symphonic action type with inlet, ball valve, float and handle including brackets and PVC flush pipe of 32 mm bore, suitable for low level cistern complete all as specified & directed. |
| 56 | Supply, fix 15mm bore, tubes medium grade, galvanized with all fittings and fixed to walls and ceiling or laid in floors including testing complete all as specified & directed. |
| 57 | Supply, fix 20 mm bore, tubes medium grade, galvanized with all fittings and fixed to walls and ceiling or laid in floors including testing complete all as specified & directed. |
| 58 | Supply & fix 3mm thick sheet glass, pin headed, and glazing with oil putty/beading in square not exceeding 0.50sqm each pane complete all as specified & directed. |
| 59 | Supply & fix butt hinges, 100 mm long of stainless steel,complete all as specified & directed. |
| 60 | Supply & fix inPVC connections of 450mm longsuitable for 15mm dia iron pipe including PTMT nuts complete all as specified & directed. |
| 61 | Supply & fixPVC ball valves, high pressure with polyethylene float and fly nut complete screwed for iron pipe 20mm bore complete all as specified & directed. |
| 62 | Supply & fixvitreous china squatting pan of ‘Orrisa pattern’ size 580x440mm, white with, integral foot rest including replacement of ‘P’ or ‘S’ trap, lime concrete bedding and making good floor complete all as specified and directed. |
| 63 | Supply & fixpillar taps, fancy typecast copper alloy with capstan heads, chromium plated, screwed down, high pressure with or without lettered “hot” or “cold” with long screwed shanks and fly nut screwed for iron pipe of 15mm bore,complete all as specified & directed. |
| 64 | S&F PVC (SWR) pipes 110 mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors |
| 65 | S&F PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls |
| 66 | S&F PVC (SWR), junction single, (Single T) equal or unequal 110 mm bore |
| 67 | S&F 600mmx750mm fancy type bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers |
| 68 | S&F Tubular towel rail 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 69 | M&L for concrete bed for 150 mm bore pipe in PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) to drain pipes including packing under, haunching against the sides of pipes, after they are laid and tested complete all as specified and as directed. |
| 70 | M&L forSlat-glazed stoneware drain pipes 150 mm dia , grade \"A\" laid in trenches and jointed in CM 1:1 specified & directed. |
| 71 | M & L for construciton of Soakage wellsof size 1.8m dia and 3m effective depth includingexcavation and eath work in any type of soil, foundation in PCC 1:3:6, honey combed wallsmasonry with top ring of cement concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab , interconnecting pipes of RCC/DWC complete filled with brick bats complete all as shown in TD Drg No TD Drg No CEJZ/TD/58 ( SHEET NO 01/01) dt 05 May 2000 all as specified and directed. |
| 72 | M & L forconstruction of Septic tanks,100 user excavation and earth workin any type ofsoil, foundation in PCC 1:2:4,brick work in CM 1:4 RCC slab covers including RCC precast manhole cover having 6 mm plate embedded all round / fibre reinforced cover with iron frame Vent shaft and sludgechambers etc, complete complete all as shown in TD Drg No CEJZ/TD/57 ( SHEET NO 01/04 to 4/4) dt 05 May 2000 all as specified and directed |
| 73 | Excavating in post holes each not exc 0.5 Cum getting out any type of soil,returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exc 50m and making good surface all as specified and directed |
| 74 | M & L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in foundation filling mass concrete and packing of post etc .complete all as specified and directed |
| 75 | M&L forMild Steel work in tubular trussesFE-410-W (Gde E-250)Quality-A including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 allas specified and directed. |
| 76 | M&L forMS Plates (plain or chequered) FE-410-W (Gde E-250)Quality-A channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment. complete all as specified and directed. |
| 77 | S&F Mild steel screw bolts (machine made) 5 to 10mm dia with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,exc 5cm but 10cm long all as specified and directed |
| 78 | S & F pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 79 | M&L for broken stone hard core of gause n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick watered and rammed to a true surfaces complete all as specified and directed. |
| 80 | M&L for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed. |
| 81 | M & L for 100mm thick RCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in path/paving/hard standing and finishing the surfaces even and fair |
| 82 | Forming Construction joint 30mm deep x 10mm wide filled with sealing compound Grade `A\" complete all as specified & directed. |
| 83 | Forming Contraction (Dummy) joints 65 mm deep x 10mm wide, filled with sealing compound Grade `A\" complete all as specified and directed |
| 84 | M&L for pressed precast concrete interlocking paver block any shape and size confirming toIS 15658-2006 of 60mm thick M-35 grade with gray cement and pigment complete all as specified and directed |
| 85 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed |
| 86 | M & LforPCC (1:2:4), type B-1 using 20mm graded stone aggregate as in coping etc incl weathering, slightly rounded or chamfered and throating with necessary form works complete all as specified and directed. |
| 87 | S& FixVitreous China urinals, bowl type (back or corner wall type)complet including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing arround urinal back in cement fixing automatic flushing cistern withbrackets, flush pipe, grating and union for discharge pipe (exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) and providing urinal spreder of PTMT any colour for fixing with 15mm dia pipe (Minimum weight 60gms) and 50mm PVC pipe for discharge of urinal and PVC Connection of 15mm size with PTMT Nuts of length 300mm completed all as specified and directed |
| 88 | M&L for Ultra plus PE, DWCPE (Double wall corrugated)pipe conforming to IS -16098 Part-2:2013 pertaining Structured wall plastics pining system for Non-Pressure drainage and sewage 150mm bore pipe and fittings with non smooth surface, typeB complete all as specified and directed |
| 89 | Material and labour for pre-cast reinforced cement concrete 1:3:6 type C-1 (20mm graded crushed stone aggregate) as incover slab for manholes in any position and set in cement morter 1:4 including necessary form work complete all as specified and as directed |
| 90 | M&Lfor brickwork with fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed. |
| 91 | M&L forpoint wiringfor One light/Fan point controlled by onefive amps one way single pole switch complete with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn throughPVC concealed conduit 20/25 mm dia on wall/ceiling ,including replacement by new 3 mm thick phenolic laminated sheet top covers and sunk type CI/steel terminal boxes ,cromium plate screwas suitablesize for mounting ofswitch & scoketincluding 1.5 sqmm size pvc insulated unsheathed copperconductor to common earth and connecting to earth dolly complete all as specified and directed.Note: Therate quoted is deemed to be included for Penolic sheet (Hylem) and steel terminal box , cutting of hylem sheet for fixing ofswitch and scoket including cutting chases in wallmaking good to disturbed surface and matching with existing surfaces. |
| 92 | All as per Ser item No 91 here-in-before but one 3 Pin Socket out let 5 Amps on the same board. |
| 93 | All as per Ser item No 91 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board. |
| 94 | All as per Ser item No 91 here-in-before butpoint wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly. |
| 95 | Supply and fixSwitch Piano type, single pole, one way 5 Amp complete all as specified & directed. |
| 96 | S&F Switch pianotype , singlepole , one way 15 Amps complete all as specified and directed. |
| 97 | S&FSocket out let2-in-1 2/3 pin 5 Ampscomplete all as specified and directed. |
| 98 | S&F Socket outlet 2-in-1, 3 pin ,5 and 15 amps , flush type complete all as specified & directed. |
| 99 | S&FCeiling rose,3 terminal PVC/polycarbonatecomplete all as specified and directed. |
| 100 | Supply and fixMCBDB SPN 8 way double door with metal door suitable forhousing of MCBsgrouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed at site. |
| 101 | S&F MCB SP 6 to 32 Amps \"C\" Series 10 KAfixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed. |
| 102 | S&Fisolator DP 63 Amps \"C\" Series fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed. |
| 103 | S&F LEDtube light fitting 20 watt 230 Volt decorative ultra slim linear LED Lighting withaluminium housing & integrated electronic driver , including all internally pre-wired and inncluding connecting upwith twin core twisted flexible copper conductor cable with suitable sizecomplete all as specified and directed at site. |
| 104 | S&F PVC ventilating airfan single phase300 mm sweepcomplete with louver shutter and including makingof hole suitablesizefan base after cutting of brick/stone wall /suitable size of water proof ply wood complete all as specified and directed. |
| 105 | M&L for submain complete with 2x4 sqmm, single core, multi stranded copper conductor , PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn in with and including PVC concealed conduit 20/25 mm diaas per site requirement along walls/ceilingetc including 1x4 sqmm size PVC insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. Note:- (i) all three wire(Phase red colour,neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs(ii) painting over surfaceconduit to be done to match with walls/ceiling existing surfaces.(iii) Two run of wire (phase & neutral) and one run of wire (earth conductor)be measured as one length) |
| 106 | M &Lfor Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed by Engr in Charge. Note :- i) Earthing test must be carried out in presence of Engr-in-Charge.ii) The earthing resultnot more than 2 Ohms or disered earth resistance value.iii) Meggerrequired for testingwill bebe provided at site by the contractor.iv) Contractor shall submit earth resistance testing report before submission of bill. |
| 107 | Drilling and tapping cast iron water mains in osition for branch connections of internal dia 15 mm bore complete all as specified and directed. |
| 108 | S&F gun metal globe or gate valve with iron wheel jhead, screwed both ends with union, long screw with checjk nut for iron pipe of size 20 mm dia complete all as specified and directed. |
| 109 | S&F gun metal globe or gate valve with iron wheel jhead, screwed both ends with union, long screw with checjk nut for iron pipe of size 25 mm dia complete all as specified and directed. |
| 110 | S&F new generation , 10 W IP 65 LED Bollard garden light, energy saving,environmental friendly,height between 0.75-1.20 mt with soft 360 deg inverted pyramid tripod type with acrylic cover with LED lamp long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LEDs as light source including wiring for garden light from PVC junction box in the PCC foundation with 2.5 sqmm copper wire including appropriate PVC conduit connection inside PCC foundation for easy removal/fixing of cable complete all as specified and directed at site. Make : Crompton Cat Part No. LBLSN-10-CDL or its equivalent in Havells, Philips as approved by GE. |
| 111 | Supply, laying and jointing, in trenches / passing through pipes/ fixing on poles/fixing on wall with saddlesXLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 6 Sqmm, 2 coreincluding cable connecting lugs, glands, jointing fixing materials complete all as specified and directed. |
| 112 | Supply and fix cable junction box IP-55/IP-65 with metric knockouts for cable entry/cable out of size 139x119x70 mm with 4 pole connector with MCB of 06 Amp includingelectrical connections complete all as specified and directed at site. |
| 113 | Supply & Fix made up to 1 mtr long GI pipe light grade40 mm outer dia including two coats of synthetic enamel paint over a one coat of red oxide primer withincluding drilling of holes for incomer and outgoing of cable/service connections/ road crossing etc complete all as specified and directed at site. |
| 114 | Trenchless boring under road crossings/foot paths by manual / Boring machine complete all as specified and directed at site. |
| 115 | Supply only dry sand cushioning to underground cables with 8 CM thick before laying of cables and 15 CM thick after laying and stretching of cable complete all as specified and directed. Note:- Punned down thickness shall be considered for measurement. |
| 116 | Supply and laying Old size sub class ‘B’ bricks, laid in trenches as cable covers complete all as specified and directed. |
| 117 | M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping of garden light poles including necessary form work and fair finshing to exposed surface without using extra cement complete all as specified and directed. |
| 118 | S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998 |