| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 02-12-2025 | BOQ AND OTHER CORRIGENDUM 01 | Other | 13-12-2025 |
| 2 | 02-12-2025 | BOQ AND OTHER CORRIGENDUM 01 | BOQ | 13-12-2025 |
| Sl. No. | Item Description |
| 1 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as per specified and as directed by Engineer-in-charge. |
| 2 | Dismantling framed trusses span n exc 10 mtr, complete all as per specified and as directed by Engineer-in-charge. |
| 3 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation board/Slabs/blankets of any thickness including cover fillets, complete all as specified and as directed by Engineer-in-charge. |
| 4 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and as directed by Engineer-in-charge. |
| 5 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) not exceeding 1.5 Sqm each and removing from site, complete all as specified and as directed by Engineer-in-charge. |
| 6 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm but not exceeding 4 Sqm each and removing from site, complete all as specified and as directed by Engineer-in-charge. |
| 7 | Taking up or down 15 mm steel tubing and connections, including cleaning for refixing or removal to store, complete all as per specified and as directed by Engineer-in-charge. |
| 8 | Taking up or down 20 mm steel tubing and connections, including cleaning for refixing or removal to store, complete all as per specified and as directed by Engineer-in-charge. |
| 9 | Taking up or down 25 mm steel tubing and connections, including cleaning for refixing or removal to store, complete all as per specified and as directed by Engineer-in-charge. |
| 10 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in hard/dense soil complete all as per specified and as directed by Engineer-in-charge. |
| 11 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in hard/dense soil, complete all as per specified and as directed by Engineer-in-charge. |
| 12 | Removing excavated materials to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point, complete all as per specified and as directed by Engineer-in-charge. |
| 13 | Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engineer-in-charge. |
| 14 | M&L for PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as per specified and as directed by Engineer-in-charge. |
| 15 | M&L for fly ash brick work with Modular bricks, straight or curved on plan exc. 6m mean radius in cement mortar 1:6, complete all as per specified and as directed by Engineer-in-charge. |
| 16 | M&L for brick work with fly ash Modular bricks straight or curved on plan in CM 1:4 as in half brick thick walls, complete all as specified and as directed by Engineer-in-charge. |
| 17 | M&L for external rendering 20 mm (10+10) thick in two layer, first layer shall be of 10 mm thick CM 1:6 and second layer of finishing coat shall be 10 mm thick in CM 1:4 mixed with WPC@ 200 ml per 50 Kg cement bag or as per manufacturer\"s instructions on brick work or concrete surfaces of wall including finishing the surface even and fair without using extra cement complete all as specified and as directed by Engineer-in-charge.(Note: WPC shall be measured and paid separately as supply only under relevant item.) |
| 18 | Supply only Liquid water proofing compound confirming to IS complete all as per specified and as directed by Engineer-in-charge. |
| 19 | M&L for 15 mm thick rendering in CM (1:6) on fair faces of brick work or concrete surfaces and finished the surface even & smooth without using extra cement, complete all as specified and as directed by Engineer-in-charge. |
| 20 | Material & Labour for preparing of new plastered surface of wall and applying finishing walls with Acrylic Smooth exterior paint of required shade : New workTwo or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and as directed by Engineer-in-charge. |
| 21 | M&L for preparation of newly plasteredsurfaces of walls and applying two coats of oil bound distemper over a coat of primer after applying 2 coats of cement based wall putty 1 mm eachto wall surface, complete all as specified and as directed by Engineer-in-charge. |
| 22 | M&L for RCC (nominal Mix) type A-1, 1:1.5:3 (20 mm graded aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc, complete all as per specified and as directed by Engineer-in-charge. |
| 23 | M&L forRCC type A-1, 1:1.5:3 (20 mm graded aggregate) (using 20 mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and as directed by Engineer-in-charge. |
| 24 | M&L for formwork to sides and soffits of floor or roof beams, beam haunching\"s, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. rough finished surfaces of concrete flat etc., complete all as per specified and as directed by Engineer-in-charge. |
| 25 | M&L for formwork to sides of concrete foundation, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter rough finished surface of concrete flat complete all as per specified and as directed by Engineer-in-charge. |
| 26 | M&L forRCC type A-1, 1:1.5:3 (20 mm graded aggregate) (using 20 mm graded aggregate) as in chajjas, beam, column, roof, landing, shelf, platform, facia and like, complete all as per specified and as directed by Engineer-in-charge. |
| 27 | M&L for Formwork to chullah hoods, chajjas, weather shades, corbels, water troughs and similar items including edges, rough finished surfaces of concrete flat etc., complete all as per specified and as directed by Engineer-in-charge. |
| 28 | M&L for precast cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar 1:6, complete all as specified and as directed by Engineer-in-charge. |
| 29 | M&L for Mild steel TMT bars 10 mm dia. and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as per specified and as directed by Engineer-in-charge. |
| 30 | M&L for Mild steel TMT bars 6 to 8 mm dia. cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as per specified and as directed by Engineer-in-charge. |
| 31 | M&L for mild steel TMT bars 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders, complete all as per specified and as directed by Engineer-in-charge. |
| 32 | S&F of roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Confirming to Fe 410-W (Gde E- 250) quality-A, includingsteel is painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication complete all as per specified and as directed by Engineer-in-charge. |
| 33 | M& L for MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to Fe 410-W (Gde E- 250) quality-A, includingsteel is painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication complete all as per specified and as directed by Engineer-in-charge. |
| 34 | S&F of screw bolts (machine made) (diameter = 16 to 20 mm) with hexagonal or square head at one end and screwed the other or screwed both ends to be fitted with washers and one hexagonal or square nut exc. 22.5 cm but n.exc. 30 cm long MS Work as in bands , straps, supports or stays incl bolts, if reqd. , hold fasts, wall ties and similar small articlesconforming to Fe-290 Gde E-165 complete all as specified and as directed by Engineer-in-charge. |
| 35 | S&F of bands, straps, supports or stays for rainwater and ventilating pipes, including bolts where required; hooks (stay type) for large gates; hook and pintle hinges; heavy hasps and staples; chains; hand-made sliding bolts; clamps; holdfasts; wall ties; fan hooks; plain angle cleats for securing purlins to wooden trusses or rafters; knee piece inserts; two-way and three-way straps; plate washers; and other similar small fittings, all fabricated from Fe-290, Grade E-165 steel, complete all as specified and as directed by the Engineer-in-Charge. |
| 36 | S&F of Pre-painted galvalume aluminium zinc coating GI based corrugated or semi-corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as specified and as directed by Engineer-in-charge. |
| 37 | S&F of Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as specified and as directed by Engineer-in-charge. |
| 38 | S&F of Anodised aluminium snap grid frame work for false ceiling confirming IS 733,737 & IS:1285, complete all as specified and as directed by Engineer-in-charge. |
| 39 | M&L for 4mmthick non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws fixed in ceiling flat or sloping, complete all as per specified and as directed by Engineer-in-charge. |
| 40 | Demolition of unreinforced cement concrete in ground floors and paving\"s nexc 15 cm thickness (below or above ground level) complete all as specified and as directed by Engineer-in-charge. |
| 41 | M&L for 100 mm thick PCC 1:4:8, type D2 (using 40mm graded agg) as in sub base, complete all as per specified and as directed by Engineer-in-charge. |
| 42 | M&L for sand filling under floors or in foundations spreading and levelling in layers not exc. 25 cm thick including watering and consolidation, complete all as per specified and as directed by Engineer-in-charge. |
| 43 | M&L for hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface, complete all as per specified and as directed by Engineer-in-charge. |
| 44 | M&L for 40mm thick for cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates) as in floor finished even and smooth without using extra cement, complete all as per specified and as directed by Engineer-in-charge. |
| 45 | S&F of coloured non-skid ceramic tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exceeding 0.18 sqm but notexceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles over 15 mm thick screed bed or bedding layers in CM 1:6 complete all as per specified and as directed by Engineer-in-charge. |
| 46 | S&F of coloured non-skid ceramic tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exceeding 0.18 sqm but notexceeding 0.38 sqm, on vertical surfaces such as skirting, dados and risers to stepsetc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match including 10mm thick rendering in cm(1:4) on surfaces as backing coat of dado/skirting etc., complete all as specified and as directed by Engineer-in-charge. |
| 47 | M&L for coloured glazed ceramic tiles 350x 250x 7 mm/ 450X 350X 7mm thick, on vertical surfaces such as skirting, dados and risers to steps etc conforming to IS - 13712 grade IB-III, set and jointed in neat cement slurry and pointed in white or Coloured cement to match over 10 mm thick screed bed or bedding layers in CM 1:4 complete all as per specified and as directed by Engineer-in-charge. |
| 48 | M&L for 75 mm thick PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection with saucer drain / footpath laid in panels and finished even and smooth with using extra cement including necessary form work complete all as specified and as directed by Engineer-in-charge.Note : Joints 12mm wide to the full depth of PCC shall be provided at every 3 meters and at every change of direction and shall be filled with mixture of bitumen and sand 1:3 by weight. Cost of this provision shall be deemed to be included in the quoted rate for concrete in plinth protection. |
| 49 | M&L for 75 mm thick PCC type C-2, 1:3:6 (using 40 mm graded aggregate) as in flooring, plinth protection/footpath finishing cement concrete surface even and fair without using extra cement, complete all as specified and as directed by Engineer-in-charge. |
| 50 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as per specified and as directed by Engineer-in-charge. |
| 51 | S&F of Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as per specified and as directed by Engineer-in-charge. |
| 52 | Supply and fixing of factory made solid panel factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as per specified and as directed by Engineer-in-charge. |
| 53 | S&F of 150 mm long aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge. |
| 54 | S&F of 125 mm long aluminium handles, cast type, anodised, complete all as per specified and as directed by Engineer-in-charge. |
| 55 | S&F ofPressed steel frames of size 125x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as per specified and as directed by Engineer-in-charge. |
| 56 | M&L for providing plain cementconcrete type C-1, 1:3:6, (using 20 mm graded stone aggregate), as in copings, bed block for filing hollow space of steel chowkhats, fixing of hold fast, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work, complete all as per specified and as directed by Engineer-in-charge. |
| 57 | S&F of30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as per specified and as directed by Engineer-in-charge. |
| 58 | Supply and fixing of factory made partly glazed i.e. upper panel will be wire mesh fitted externally in the clear space & lower panel will be plain colour PVC sheet 5mm thick PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail,; Panelling of plain colour PVC sheet to be fitted in the M.S.frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as per specified and as directed by Engineer-in-charge. |
| 59 | S&F of floor door stopper 14cm long of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor complete all as per specified and as directed by Engineer-in-charge. |
| 60 | S&F of 100 mm butt hinges, medium weight, cold rolled mild steel and fixed complete all as per specified and as directed by Engineer-in-charge. |
| 61 | S&F of 200 mm long aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge. |
| 62 | S&F of 150 mm long aluminium handles, cast type, anodised, complete all as per specified and as directed by Engineer-in-charge. |
| 63 | S&F of 300 mm long mild aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as per specified and as directed by Engineer-in-charge. |
| 64 | S&F of Powder coatedaluminium window sliding type three track (2 glazed & one gauzed shutter ) aluminium sections weighing not less than 1.67kg/m for frame and 0.55 kg/m for shutter including necessary jointing cleats, glazingcleats, rubber packing , screws, handle, locking arrangement and 5.5mm thick plain/tinted glass and aluminium mosquito proof gauge including taking down of old existing steel window and making good disturbed surfaces of wall complete all as per specified and as directed by Engineer-in-charge. |
| 65 | S&F Powder coated aluminium louvered ventilators of size n exc 0.50 Sqm area with glass louvers, without sash bars of aluminium sections weighing not less than 0.605kg/m for frame of size 40x20x2mm including necessary jointing cleats, glazingcleats, rubber packing , anodised aluminium snap beading, screws, anodised aluminium fittings and 5.5mm thick tinted glass fixed in panels with suitable locking arrangementsincluding taking down of old existing steel ventilator and making good disturbed surfacesof wall complete all as per specified and as directed by Engineer-in-charge. |
| 66 | M&L for providing & fixing factory made solid PVC cup board frame of size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5 mm thick prelam/plain colour PVC sheet reinforce with 19mm x 19mm MS square tube of 19 gaugethickness throughout the frame and metre cut at two cornersand jointed with 2 no\"s of 150mm long brackets of 15mm x 15mm MS square tubes. The door frame shall be fixed to the wall using 100mm long MS screws through the frame by using PVC fasteners. A minimum 4 no\"s of screws to be provided for each vertical member and minimum 2 no\"s of screws to be provided to the horizontal member etc., complete all as per specified and as directed by Engineer-in-charge. |
| 67 | M & L for providing & fixing factory made solid PVC two track sliding type cup board shutter (Flush type) of 24 mm thick made from co-extruded 3 layer rigid PVC foam sheet (single extruded) with density not less than 600kg/cob outer layer (.8-1mm) thick should be of rigid PVC with density of not less than 1400kg/cob manufactured bayan ISO 9001-2015 certified company. Door should be water proof, termite proof, fire retardantand having good screw holding capacity , with all sliding and locking arrangement including taking down old unserviceable, complete all as per specified and as directed by Engineer-in-charge. |
| 68 | S&F in repair of providing and fixing factory made PVC shelf/ partition of required size consisting of20mm thick Solid PVC Sandwich Panel with 1mm Plain PVC Sheet on both sides suitably fixed in M.S. angle frame work as per specification & drawing, complete all as per specified and as directed by Engineer-in-charge. |
| 69 | S&F of for 75 mm Hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws, complete all as per specified and as directed by Engineer-in-charge. |
| 70 | S&F of 75 mm long aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge. |
| 71 | S&F in repair of Harrison rails curtain rod, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as per specified and as directed by Engineer-in-charge. |
| 72 | S&F in repair of MS 300mm, ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and as directed by Engineer-in-charge. |
| 73 | S&F of Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed, complete all as specified and as directed by Engineer-in-charge. |
| 74 | S&F in repair of stainless steel wire cloth, 0.36 mm dia of wire and average width of aperture 1.40 mm and fixed with tinned stacks, or galvanized wire staples complete all as per specified and as directed by Engineer-in-charge. |
| 75 | M&L for preparation of new or previously untreated wood or wood based surfaces of any description, exceeding 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed by Engineer-in-charge. |
| 76 | S&F in repair of sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, complete all as per specified and as directed by Engineer-in-charge. |
| 77 | S&F in repair of Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size(flat back or angle back type) including cutting for and pinning ends of brackets and including, waste pipe, CP waste coupling etc., complete all as per specified and as directed by Engineer-in-charge. |
| 78 | S&F in repair of 15mm dia bore fancy type pillar tap cast copper alloy with capstan heads chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly-nuts, screwed for iron pipe complete all as per specified and as directed by Engineer-in-charge. |
| 79 | S&F in repair of toilet paper holder with flat recessed type stainless steel including all necessary fittings, complete all as per specified and as directed by Engineer-in-charge. |
| 80 | S&F in repair of 600x450mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as per specified and as directed by Engineer-in-charge. |
| 81 | S&F in repair of PVC valveless, symphonic action type 10 litre capacity low level flushing cistern, white, with inlet, ball valve, float and handle including brackets and 32 mm bore PVC flush pipe, complete all as per specified and as directed by Engineer-in-charge. |
| 82 | S&F in repair of Vitreous China wash down water closet pan (pedestal pattern), white, including connection to drain (or outgoing pipe) and to flushing pipe, anti siphonage pipe, etc., complete all as per specified and as directed by Engineer-in-charge. |
| 83 | S&F in repair of plastic water closet seat cover, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, complete all as per specified and as directed by Engineer-in-charge. |
| 84 | S&F in repair of Bib taps fancy type cast copper alloy, chromium plated for 15mm bore pipe, screwed for iron pipes or for brass ferrule, complete all as per specified and as directed by Engineer-in-charge. |
| 85 | S&F in repair of Stop valves, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as per specified and as directed by Engineer-in-charge. |
| 86 | S&F in repair of Gun-metal 20 mm bore pipe, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as per specified and as directed by Engineer-in-charge. |
| 87 | S&F in repair of 15mm dia PVC connection pipe with PTMT nuts of length 600mm complete all as specified and as directed by Engineer-in-charge. |
| 88 | S&F in repair of two way bib cock with wall flange chromium plated with crutch or butterfly handle screwed down screwed for iron pipe 15 mm bore and fixed, complete all as per specified and as directed by Engineer-in-charge. |
| 89 | S&F in repair 15 mm bore angle cock CP with flange complete all as per specified and as directed by Engineer-in-charge. |
| 90 | S&F in repair of Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position, complete all as per specified and as directed by Engineer-in-charge. |
| 91 | S&F in repair of brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges, complete all as per specified and as directed by Engineer-in-charge. |
| 92 | S&F in repair of Soap dish, vitreous China white, approximate size 160x 160x90 mm, complete all as per specified and as directed by Engineer-in-charge. |
| 93 | S&F in repair of towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms), complete all as per specified and as directed by Engineer-in-charge. |
| 94 | S&F in repair of Brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union, complete all as per specified and as directed by Engineer-in-charge. |
| 95 | S&F in repair of glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard & railing 60 cm long, complete all as per specified and as directed by Engineer-in-charge. |
| 96 | Dismantling water tanks of capacity exc. 500 and not exc. 1000 litres, complete all as per specified and as directed by Engineer-in-charge. |
| 97 | S&F of rotational moulded PVC water storage tank 1000 litres capacity conforming to IS-12701(1989) cylindrical vertical type multi-layered with closed top including inlet, outlet and wash out holes of approved make hoisted and fixed in position all as specified in SSR Part-I, 2009 etc., complete all as specified and as directed by Engineer-in-charge. |
| 98 | Demolition of stone slabs and tiles laid dry or laid dry and pointed of any description or thickness in floors, approaches, dado/Partitionsetc, complete all as per specified and as directed by Engineer-in-charge. |
| 99 | M&L for 18 to 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite stone including griding & polishing with complete all as specified and as directed by Engineer-in-charge.Note : Hole to be provided in granite slab for gas pipe in kitchen platform etc. |
| 100 | Supply and laying of GI tube 15 mm bore medium grade with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by Engineer-in-charge. |
| 101 | Supply and laying of GI tube 20 mm bore medium grade with fittings and fixed in trenches complete all as specified and as directed by Engineer-in-charge. |
| 102 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as per specified and as directed by Engineer-in-charge. |
| 103 | S&F of 75 mm dia PVC (SWR) pipes single socketed, in any length,laid in trenches or in floors, complete all as per specified and as directed by Engineer-in-charge. |
| 104 | S&F 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls, complete all as per specified and as directed by Engineer-in-charge. |
| 105 | S&F of PVC (SWR) 75 mm bore bends complete all as per specified and as directed by Engineer-in-charge. |
| 106 | S&F of 110 mm dia bore PVC (SWR) junction (single T) equal or un-equal with access door, complete all as per specified and as directed by Engineer-in-charge. |
| 107 | S&F of 110 mm dia bore PVC (SWR)bends, complete all as specified and as directed by Engineer-in-charge. |
| 108 | M&L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement, complete all as per specified and as directed by Engineer-in-charge. |
| 109 | S&F in repair of 75mm PVC (SWR) floor trap with grating including jointing with solvent cement complete all as per specified and as directed by Engineer-in-charge. |
| 110 | M&L for 100 mm dia (internal) salt glazed stone ware drain pipes (Grade A) ISI Marked as in sewage lines laid in trenches and jointed complete all as specified and as directed by Engineer-in-Charge. |
| 111 | M&L for concrete bed 1:3:6 type C2 (40 mm graded stone aggregate) to 100 mm dia. drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested, complete all as per specified and as directed by Engineer-in-charge. |
| 112 | Excavation for soakage well in any type of soil; providing foundation in PCC 1:3:6; constructing walls in honey-combed masonry with a top ring in M-25 concrete; providing intercepting chamber and screen chamber in brick masonry in cement mortar; supplying and fixing RCC cover slab in M-25 grade/SFRC cover; laying interconnecting pipes of RCC/DWC; and filling the soakage well completely with brick bats. The soakage well shall be of size 1.2 m × 1.5 m with effective depth as specified. Complete all as specified and as directed by the Engineer-in-Charge |
| 113 | Dismantling wrought iron or mild steel work of any description not otherwise providedcomplete all as specified and as directed by Engineer-in-charge. |
| 114 | M&L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as per specified and as directed by Engineer-in-charge. |
| 115 | M&L for preparation of new or previously untreated steel or iron surface of any description and applying two coats of synthetic enamel paint over a coat of red oxide, primer over 10cm width or girth complete all as specified and as directed by Engineer-in-charge. |
| 116 | M&L for Anti-termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as per specified and as directed by Engineer-in-charge. |
| 117 | M&L for Providing and injecting chemical emulsion for Post Constructional Anti-termite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as per specified and as directed by Engineer-in-charge. |
| 118 | M&L for Providing and injecting chemical emulsion for Post Constructional Anti-termite Treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same, complete all as per specified and as directed by Engineer-in-charge. |
| 119 | M&L for plain cement concrete type C-2, 1:3:6 (using 40 mm gradedstone aggregate) as in surface channels and drains, complete all as specified and as directed by Engineer-in-charge. |
| 120 | M&L forRCC type A-1, 1:1.5:3 (20 mm graded aggregate) (Nominal Mix)(using 20 mm graded aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc, complete all as per specified and as directed by Engineer-in-charge. |
| 121 | S&F MS steel work in tubular trusses including special shaped washersetc., complete using ERW or induction butt welded tubes confirming to IS 1161- 1979 graded St 240 including steel is painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication complete all as per specified and as directed by Engineer-in-charge. |
| 122 | M&L for Moorum/red bajri filling in floors or paving\"s, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering, complete all as specified and as directed by Engineer-in-charge.Note :The Moorum/red bajri work shall be measured after consolidation. |
| 123 | M&L for 25 mm thick for cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates) as in floor finished even and smooth without using extra cement, complete all as per specified and as directed by Engineer-in-charge. |
| 124 | S&F in repair of 20 mm ballvalves, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 15mm-142gms/ 20 mm - 210gms/25mm-455gms/ 40mm - 690 gms) and fixed in position complete all as per specified and as directed by Engineer-in-charge. |
| 125 | S&F of 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls, complete all as per specified and as directed by Engineer-in-charge. |
| 126 | S&F of PVC (SWR) 110 mm bore bends with access door complete all as per specified and as directed by Engineer-in-charge. |
| 127 | S&F of 110mm dia PVC (SWR) branch piece single (single \"Y\") equal or unequal with access door complete all as per specified and as directed by Engineer-in-charge. |
| 128 | S&F of 110mm dia PVC SWR vent cowl complete all as per specified and as directed by Engineer-in-charge. |
| 129 | S&F of 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls, complete all as per specified and as directed by Engineer-in-charge. |
| 130 | S&F of 75 mm bore PVC (SWR) junction single (Single `T\") equal or unequal with access door complete all as per specified and as directed by Engineer-in-charge. |
| 131 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engineer-in-charge. |
| 132 | M&L for salt-glazed stoneware gully traps, square or round mouthed, type `P\" 150x100mm complete all as directed by Engr-in-Charge |
| 133 | Removing building materials and debris (other than excavated earth) to a distance of 5 KM inside MD Land at locations specified including loading and dumping/ levelling at thedestination complete all as specified and as directed by Engineer-in-charge. |
| 134 | M&L for 75 mm thick cement concrete (1:2;4) type B2 (40mm graded broken stone aggregate) as in floor of platform over cement concrete, brick work, hard standing laid in bays, finished even and smooth using extra cement, complete all as specified and as directed by Engineer-in-charge. |
| 135 | M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick set jointed and pointed in with grey cement and no pigmentlaid over floor and pointed in neat cement slurry in floors including 15 mm thick screed in CM (1:6), complete all as specified and as directed by Engineer-in-charge. |
| 136 | M&L for brick work with sub-class `B\" old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge. |
| 137 | M&L for 25 mm thick PCC (1:2:4) type B-0 (12.50 mm graded stone aggregate) , as in under layer levelling course for Bath, WC floor below tiles finished even and rough, complete all as specified and as directed by Engineer-in-charge. |
| 138 | Taking down carefully old unserviceable copper/ aluminium point wiring (light, exhaust fan, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, bells, sockets, tube light fittings etc., and making good disturbed surface of walls & Floors etc., complete all as specified and as directed by Engineer-in-charge. |
| 139 | M&L for concealed point wiring with two single core PVC insulated, unsheathed, multistranded copper conductor FRLS of size 1.5 Sq. mm and one single core PVC insulated unsheathed stranded copper conductor of size 1.50 Sq. mm green in colour as earth lead in and including PVC rigid conduit (medium grade) with all fittings & accessories for mounting switch, sockets, fan regulators etc. for one light, complete all as specified and as directed by Engineer-in-charge. |
| 140 | All as per serial item No. 139 as above but for one fan point controlled by one switch, complete all as specified and as directed by Engineer-in-charge. |
| 141 | All as per serial item No. 139 as above but for socket outlet 5/6 AMPs point on independent board, complete all as specified and as directed by Engineer-in-charge. |
| 142 | All as per serial item No. 139 as above but for socket outlet 5/6 AMPs point on same board, complete all as specified and as directed by Engineer-in-charge. |
| 143 | All as per serial item No. 139 as above but wiring with single core, multistranded copper conductor of size 2.5 sqmm for socket out let point on independent board, complete all as specified and as directed by Engineer-in-charge. |
| 144 | All as per serial item No. 139 as above but for one Bell point controlled by one switch, complete all as specified and as directed by Engineer-in-charge. |
| 145 | All as per serial item No. 139 as above but for one light point controlled by two way switch, complete all as specified and as directed by Engineer-in-charge. |
| 146 | S&F of switch piano flush type, 6/5 Amps 240 volts single pole one way, complete all as specified and as directed by Engineer-in-charge. |
| 147 | S&F of switch piano flush type, 16/15 Amps 240 volts single pole two way, complete all as specified and as directed by Engineer-in-charge. |
| 148 | S&F of Bell push, flush type, 5 Amp 240 volts, complete all as specified and as directed by Engineer-in-charge. |
| 149 | S&F of Buzzer, Ding Dong AC 230 volts, single pole, complete all as specified and as directed by Engineer-in-charge. |
| 150 | S&F ofSocket outlet 2 in 1, 3 pin, 5/6 Amp, complete all as specified and as directed by Engineer-in-charge. |
| 151 | S&F of Socket outlet 2 in 1, 3 pin, 6 and 16 amp flush type, complete all as specified and as directed by Engineer-in-charge. |
| 152 | S&F of Switch piano, flush type single pole, one way 16 Amp, complete all as specified and as directed by Engineer-in-charge. |
| 153 | Supply and fixing of fan regulator electronic type, rotary step(speed regulation in 5 steps), SP 240 Volt, suitable for ceiling fans complete all as specified and as directed by Engineer-in-charge. |
| 154 | Supply and fixing of ceiling rose surface PVC three terminals, PVC/ polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge. |
| 155 | Supply and fixing of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed by Engineer-in-charge. |
| 156 | Supply and fixing in repair of LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engineer-in-charge. |
| 157 | Supply and fixing in repair of LED light fitting 1x9W/1X10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-in-charge. |
| 158 | Supply and fixing in repair of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and as directed by Engineer-in-charge. |
| 159 | Supply and fixing of sheet metal enclosure powder painted for MCB SPN 8 way double door DB, 240 Volts, 200 Amp with din rail and bus bar including making good to the disturbed surface matching including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge. |
| 160 | Supply and fixing of amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SPN 40 to 63 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge. |
| 161 | Supply and fixing of amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SP 6 To 32 AMP current carrying capacity in the MCB DB complete with connection testing and commissioning including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge. |
| 162 | Taking down carefully Ceiling fan from its original position and refixing / hanging after plaster work after cleaning all dust etc, complete all as specified and as directed by Engineer-in-charge. |
| 163 | Supply and fixing in repair of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and as directed by Engineer-in-charge. |
| 164 | S&F of street light bracket made out of GI tubing 25 mm bore medium grade 1.20 Mtr long bend to required shape as in bracket for street light fittings fixed with two No of MS flat iron 25mm x 5mm size and 30cm long clamp of required shape with bolts nuts and washers suitable for building security light including painting of mild steel flat iron surfaces with two coats of synthetic enamel paint over a coat of red oxide primer including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge. |
| 165 | Supply and fixing of electric water heater, storage type, ABS plastic body with steel inner tank with fero-glass coating and heating element up to 2 KW, capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection pipes, connection plug, hanging accessories with 6-inch expansion anchor bolt etc. including taking down of old unserviceable geyser and deposited to MES store yard complete all as specified and as directed by Engineer-in-charge. |
| 166 | S&F of exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers including taking down of old unserviceable fan and deposited to MES store yard complete all as specified and as directed by Engineer-in-charge. |
| 167 | Supply and fixing in repair of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-in-charge. |
| 168 | M&L for sub main wiring two run of size 6 sqmm PVC insulated, ISI marked, FRLSH unsheathed, electric power cable (heavy duty) 1100 volts grade with stranded copper conductor with 6.0 sqmm PVC insulated stranded copper conductor earth wire in PVC casing caping of suitable size (two run of 6 sqmm cable and one of 6.0 sqmm wire and one run of PVC conduit will be measured as one unit), complete all as specified and as directed by Engineer-in-charge. |
| 169 | Supply and fixing of energy-efficient ceiling fan, 230 V, 1200 mm sweep, complete with blades, down rod, remote control unit, and all necessary accessories. Fan shall have a minimum air delivery of 210 CMM and a minimum service value of 6.00 as per BEE 5-Star rating, equipped with a brushless direct current (BLDC) motor includes taking down the old unserviceable fan and depositing the same in the MES store yard, complete all as specified and as directed by the Engineer-in-Charge. |
| 170 | Excavation in trenches n. exc 1.5m wide and n. exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n. exc 10 sqm on plan and n. exc 1.5m in depth and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge. |
| 171 | Supply & Laying of Sub-Class B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.(Note. The painting shall be carried out through mechanical appliances by the company\"s approved applicator). |
| 172 | M&L for sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 8cm deep before laying and 15cm covering above the top edge of cable after laying, complete all as specified and as directed by Engineer-in-charge. |
| 173 | Supply, laying & testing of XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100Volt grade on walls with fixing accessories of size 16 Sqmm 2 Core cable including taking down old unserviceable, complete all as specified and directed by Engineer-in-charge.Note:- Excavation & earth work, sand cushioning, bricks protection & GIpipe where required shall be measured & paid separately. |
| 174 | S&F of GI tube 40 mm bore light grade for cable protection, complete all as specified and as directed by Engineer-in-charge. |
| 175 | Material and labour for earthing complete with galvanized steel plate electrodes of size 600x600x6 mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, checknuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, including necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 5 of SSR Part- I including testing including taking down old unserviceable, complete all as specified and directed by Engineer-in-charge. |
| 176 | Supply, laying of XLPE insulated PVC inner sheathed, armoured with galvanized steel strip or wire heavy duty underground cable withstranded aluminiumconductor 1100 volt grade of size 25 Sqmm 2 Core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing including testing including taking down old unserviceable, complete all as specified and directed by Engineer-in-charge.Note:- Excavation & earth work, sand cushioning, bricks protection & GIpipe where required shall be measured & paid separately. |
| 177 | Supply and laying of GI tube 25 mm bore medium grade with all fittings and fixed in trenches complete all as specified and as directed by Engineer-in-charge. |
| 178 | Supply and fixing in repair of Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed by Engineer-in-charge. |
| 179 | M&L for Cutting existing steel tubing 25 or 32 mm bore for alterations or additions (Each cut measured) complete all as per specified and as directed by Engineer-in-charge.NOTE:-The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule \"A\"/BOQ. |