| 1 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m for all Kinds of soil by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level 1:5:10 (1 Cement : 4 fine sand : 8 graded stone aggregate 40 mm nominal size). by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level 1:4:8 (1 Cement : 4 fine sand : 8 graded stone aggregate 40 mm nominal size). by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item |
| 4 | Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand). by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item |
| 5 | providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | Providing and laying in position specified gradereinforcedcement concrete, excluding the cost of centering,reinforcement - Allwork up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 9 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item |
| 10 | providing and fixing upto floor five level precast cement concrete solid block including hoisting and setting in position cement mortar 1 5 (1 cement 5 course sand ) cost of centering shuttering complete |
| 11 | Providing and laying cement concrete in retaining returnwalls, walls thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: |
| 12 | Centring and shuttering including strutting,ropping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item |
| 13 | Centring and shuttering including strutting,ropping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform . by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item. |
| 14 | Centring and shuttering including strutting,ropping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers . by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item. |
| 15 | Centring and shuttering including strutting,ropping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item |
| 16 | Structural steel work riveted, bolted or welded in built kilogram up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: |
| 17 | Marble stone flooring with 18 mm thick marble stone, as sampleof marble approved by Engineer-in-charge, over 20 mm (average)thick base of cement mortar 1:4 (1 cement : 4 coarse sand) jointed with grey cement slurry, including rubbing and polishingcomplete with :udaipur green marble |
| 18 | providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 19 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). |
| 20 | Cement plaster 1:6 (1 cement: 6 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster |
| 21 | cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 22 | providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick |
| 23 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. |
| 24 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:3 0 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 25 | Providing and fixing panelled or panelled and glazed shutters for d and clerestory windows including ISI marked black enamelled M.S necessary screws excluding panelling which will be paid for separa Chir Wood 30 mm thick shutters |
| 26 | providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.Float glass panes 4 mm thick mm thick glass pane (weight not less than 10 kg/sqm). |
| 27 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm as per directions of Engineer-in-charge work to be execuated as per specification a rate of above given item |
| 28 | Providing and fixing aluminium tower bolts, 150x10 mm ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 29 | Providing and fixing aluminium handles, 100 mm ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 30 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Twin rubber stopper . as per directions of Engineer-in-charge work to be execuated as per specification a rate of above given item |
| 31 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item (110 mm diameter ) |
| 32 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 33 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 34 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 35 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item |
| 36 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item |
| 37 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 38 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. ixed to steel windows by welding Please Enable Macros to View BoQ information |