| 1 | Demolition of brick work/solid block workbuilt in cement mortar including all quoins, pillars etc. complete all as specified and as directed |
| 2 | Demolition of unreinforced cement concrete of any description as in coping over compound wall complete all as specified and as directed |
| 3 | Material and labour providingPCCsolid blocksmasonry exc. 10cm in widthtype C1 1:3:6, 20mm graded aggregate and setting in cement mortar 1:6 complete all as specified and as directed |
| 4 | Taking down cement plastering any description on brick or stone walls including raking out joints, hacking for key, scrubbing down with water etc completed all as specified and directed. |
| 5 | Material and labour for cement concrete type – B-1 (1:2:4) using 20mm graded stone aggregate as in coping over compound wall complete all as specified and directed |
| 6 | Rendering 8mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 with approved water proofing compound over backing coat of 12 mm thick in CM 1:6 finished even and smooth with out using extra cement completed all as specified and directed |
| 7 | Rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth with out using extra cement complete all as specified and directed. |
| 8 | Rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:3 finished even and smooth with out using extra cement for ceilingcompleted all as specified and directed. |
| 9 | Material and labour forFinishing walls with two coat of Acrylic Smooth exterior emulsion ( Anti Fungal Nature ) paint of ( as approved/ required shade) ofNew workover a coat of exterior grade primer (Two coat applied @ 1.67 ltr/10 sqm over andexterior primer applied @ 2.20 kg/10 sqm)completed all as specified and directed. |
| 10 | Material and labour for preparation of old painted surfaces with complete removal of existingtreated walls and applying two coat of Acrylic Smooth exterior emulsion paint ( Anti Fungal Nature ) of ( as approved/ required shade) ofexisting surface over a coat of exterior grade primer(Twocoat applied @ 1.67 ltr/10 sqm over and exterior primer applied @ 2.20 kg/10 sqm)completed all as specified and directed. |
| 11 | Material and labour for preparation of newly plastered wall surfaces and applying two coats of oil emulsion distemper over a coat of alkali resistant primer including 1.5mm wall care putty complete all as specified and directed. |
| 12 | Complete removal of existing treatment preparation of old decorated surfaces (White/Colour wash/distemper) of walls including cornices plasters etcincluding washing rubbing & scraping down and applying two coat of acrylic based distemper over a coat ofalkali resistant ( acrylic based )primerincl 1.5mm thick wall care putty on oldplastered surface wall complete all as specified and directed.. |
| 13 | Material and labour for preparation ofold decorated ceiling surfaces and applying two coats of white wash on ceiling surfaces completed all as specified and directed. |
| 14 | Material and labour for complete removal of existing treatment and applying two coat of oil bound distemper over a coat of alkali resistant (acrylic based) primer on ceiling complete all as specified and directed. |
| 15 | Material and labour preparation of newly plastered ceiling undecorated with two coats of oil bound distemper over a coat of alkali resistant primer (acrylic based) complete all as specified and directed. |
| 16 | Dismantling wrought iron or mid steel work of any description not otherwise provided for complete all as specified and directed |
| 17 | Material and labour for framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc, complete, drilled for fixing of steel sheeting or other covering. Doors etc to be prepared for hanging orsliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete confirming to Fe -410 W Garde E-250(Quality B) complete all as specified and directed. |
| 18 | Material and labour for preparation ofnew steel and iron surfaces of any description n. exc 10cm in width or girth and apply two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed. |
| 19 | Material and labour for preparation of new steel /iron surfaces of any description exc 10cm in width or girth and apply two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed. |
| 20 | Material and labour for preparation of old painted steel/iron surfaces exc 10cm width or girth and applying one coat of synthetic enamel paint oncomplete all as specified and directed. |
| 21 | Material and labour for preparation of old treated wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 22 | Supply only Liquid water proofing compound complete all as specified and directed. |
| 23 | Material and labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sq. mm 3 1/2 core fixed on walls with proper clamps, laid under floor or fixed in existing cable trays with cable ties complete all as specified and directed. |
| 24 | All as per item No 23 here-in-before but armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm 3 1/2 core complete all as specified and directed. |
| 25 | Supply and fixon load Change over switch with enclosure 4 Pole, 250 Amps,415 V , complete all as specified anddirected including SS enclosure .HAVELLS Make cat part no IHCNF00250 and IHCNFE0250 or L&T, Indo Asian complete all as specified and directed. |
| 26 | Taking down existing outdoor typeLT panel board / bus bar bhamber with main switches,MCCB\"s etc. after disconnecting the incoming and out going cables, earthing stripswith angle iron frame etc and removing to store including transportation, loading, unloading etc complete all as specified and directed. |
| 27 | Supply and fixing , design, erection and commissioning of LT panel board outdoor type platform mounted fabricated through CPRI approved factory manufacturersand type tested for IP-65 protection totally enclosed dust and vermin proof openable from both front and rear side made out of self supported 3.00 mm thick CRCA (Cold Rolled Cold Annealed) MS sheet of suitable length, width and height as per IE rule to accomodate all the items and conforming to IEC-61439 and built upon 40 x 40 x 6 mm size angle frame work and lugs fixed on existing cable trenches having fron t and rear hinged doors with neoprene rubber gasket, danger plate, GI earthing strips at rear side, bottom detachable gland plate complete with suitable size single plated and passivated nuts, bolts, spring washers. The cabinet and all members shall be chemically treated with MSR solution for aircorrosive treatment and powder coated (shade RAL - 7032) with 9 tank process and shall be with IP-65 grade protection. The panel shall be suitable for 415 volts, 50 Hz 3 phase 4 wire system and internal connections which shall be provided with aluminium strips of suitable size and comprising of the following accessories complete all as specified and directed.BUS BAR CHAMBER : (i) Sheet steel bus bar chamber having front hinged covers with a set of electrolytic grade high conductivity TP&N solid Aluminium bus bars, rated 400 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - 01 No (Set of 04) (i) MCCB, 4 pole, 250 Amps, 50 KA (Incomer) -1 N0(ii) MCCB, 4 pole, 125 Amps - 8 Nos9One standby)(iii) Digital volt meter 500 V - 1 nos(iv)Digital Ampere meter wih CT\"s 1 - nos(v) Indicator lamps - 1 set (vi) All electrical connections with proper cable thimbles, cable glands etc as per site requirement. |
| 28 | Material and labour for earthing completewith copper earth plate electrode 60cm x 60cm x 3mm thick buried directly in ground (earth pit not less than 2.25 Mtrs below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to copper strip 20x3 mm by means of nuts, bolts, thimbles, chuck nuts, washers of Cu or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-Iand specified includingprovision of earth strip protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation andearth work & connecting the earthing to an earthing test point /transformer nuetral/body/ Lt panel/DG set etc. and testing on completion, complete all as specified and directed. |
| 29 | Supply and fix Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20x3 mm copper strip complete all as specified and directed. |
| 30 | Material and labour for earthing completewith galvanized iron or steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtrs below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to galvanized iron strip 32x6 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-Iand specified includingprovision of earth wire protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation andearth work & connecting the earthing to an earthing test point /transformer nuetral/body/ Lt panel etc. and testing on completion, complete all as specified and directed. |
| 31 | Material and labour for cutting existing road/hardstand/concrete blocks/slabs/brick work or stone masonry of any type by using crow bar chisel up to adepth of 30 cm for layingGI pipe including making good the surface by returning filling watering ramming in layers cold mix bitumen over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed. |
| 32 | Supply and fix GI tubing medium grade (ISI marked) with all fitting/acessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc ofsize 50mm dia complete all as specified and directed. |