| Sl. No. | Item Description |
| 1 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 2 | Dismantling framed trusses span n.exc 10 mtr complete all as specified and directed. |
| 3 | Dismantling of wall and ceiling Boards (Fiber, pulp, Insulation etc) or insulation Board/ slab/ blankets any thinkness including cover fillets complete all as specified and directed. |
| 4 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 5 | Taking down chowkats or frames with shutters (with out taking off shutters from the frames) area not exc 1.5 Sqm each complete all as specified and directed. |
| 6 | Taking down chowkats or frames with shutters (with out taking off shutters from the frames) area exc 1.5 sqm but not exc 4.0 Sqm eachcomplete all as specified and directed. |
| 7 | Takingup or down GI15mm bore pipe and connection including cleaning for refixing or removal from site as directed. |
| 8 | Taking up or down GI 20mm steel tubing and connections incl cleaning for refixing or removal to store. |
| 9 | Demolition of cement concrete of any position and description complete all as specified and directed. |
| 10 | M&L for PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 11 | M&L for brickwork with burnt fly ash old size bricks, straight or curved on plan exc 6m meanradius, built in cement mortar (1:6) complete all as specified and directed. |
| 12 | M&L for brickwork with burnt fly ash old size bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar (1:4) complete all as specified and directed. |
| 13 | M&L for external rendering 20 mm thick in two layers, first layer shall be of 10 mm thick in CM (1:6) and second layer of finishing coat shall be 10 mm thick in CM (1:4) mixed with WPC@ 200 ml per 50 Kg of cement bag on brick work or concrete surfaces of wall and finished even and fair complete all as specified and directed.Note-WPC shall be measured and paid seperately. |
| 14 | Supply only liquid water proofing compound all as specified and directed. |
| 15 | M&L for rendering 15 mm thick in CM (1:6) on fair faces of brick or concrete surface of wall and finished even and smooth without using extra cement complete all as specified and directed. |
| 16 | M&L for preparing new plastered surfaces of walls and finishing the walls with Acrylic smooth exterior paint of required shade : New work (Two or more coats applied @1.67 Ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/ 10 sqm).Make of Weather proof exterior acrylic emulsion and primer : Asian Apex Ultima/Berger weather coat long life 10 all as specified and directed. |
| 17 | M&L for preparation of newly plasteredsurfaces of walls and applying two coats of oil bound distemper over a coat of primer after applying 2 coats ofcement based wall putty 1 mm thick (Avg thickness) eachto wall surface complete all as specified and directed. |
| 18 | M&L for RCC (1:1.5:3) nominal mix type A1 (using 20 mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed.Note - Reinforcement and form work shall be measured and paid separately. |
| 19 | M&L for RCC (1:1.5:3) nominal mix type A1 (using 20 mm graded stone aggregate) as inbeam, cantilevers, bressummers, lintels over 1.5 m span and similar work complete all as specified and directed.Note - Reinforcement and form work shall be measured and paid separately. |
| 20 | Use and waste of form work to sides and soffits of floor or roof beam, beam hauchings, girders, bressummers,lintels, cantilevers, shelves,for flatrough finished concrete surfaces complete all as specified and directed. |
| 21 | Use and waste of form work to sides ofconcrete foundation, footings, bases ofcolumns, raft and raft beams sides and soffits (if any) of foundation and plinth beams for flat rough finished concrete surface complete all as specified and directed. |
| 22 | M&L for RCC (1:1.5:3) nominal mix type A1 (using 20 mm graded stone aggregate) as in chajjas and similar work complete all as specified and directed.Note - Reinforcement and form work shall be measured and paid separately. |
| 23 | Use and waste of form work to chullah hood, chajjas, troughs and similar items including edges etc for rough finished flat concrete surface complete all as specified and directed. |
| 24 | M&L for Precast cement concrete (1:1.5:3) nominal mix type A1 (using 20 mm graded stone aggregate) as in landings, cover slab (for manholes etc)/ septic tank covers slab and similar work including necessary form work and set in CM 1:4 complete all as specified and directed. |
| 25 | M&L for mild steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 26 | M&L for mild steel TMT bar 6 to 8 mm dia cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 27 | M&L for mild steel TMT bar 5mm dia and over upto and including 10mm dia as in stirrups, spacers & binderscut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 28 | S&F rolled mild steel in structural steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe 410-W (Gde -E-250 quality- A) duly painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication all as specified and directed. |
| 29 | S&F rolled mild steel MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachmentconfirming to Fe-410-W (Gde E-250 quality B) complete all as specified and as directed by Engineer-in-charge. |
| 30 | S&F Mild steel screw bolts (machine made) with hexagonal / square heads at one end & screwed the other/ screwed both ends, each screwed end to be fitted with washers & one hexagonal or square nut, length of bolt exc 22.5cm & n exc 30cm long dia of shank 16 to 20 mm. |
| 31 | S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength 550 Mpa as in roof covering/ cladding/ eaves board fixed with selp tapping screw complete all as specified and directed. |
| 32 | S&F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength 550 Mpa as in roof covering/cladding/eaves board fixed with selp tapping screw complete all as specified and directed. |
| 33 | S&F anodised aluminium snap grid frame work of size 605x605mm for false ceilingall as specified and as directed |
| 34 | M&L for 4mm thick non asbestos, fibre reinforced standard cement board as in celiling, designer board complete all as specified and as directed |
| 35 | Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 36 | M&L for 100 mm thick Cement concrete (1:4:8)type D-2 (using 40 mm graded crushed stone aggregate) as in sub base complete all as specified and directed. |
| 37 | M&L for sand filling under floor or in foundations including watering and consolidation complete all as specified and directed. |
| 38 | M&L for broken stone or boulders hardcore of gauge exceeding 63 mm but not exceeding 100 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 39 | M&L for 40mm thick PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in floors, finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 40 | M&L for non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed. |
| 41 | M&L for non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in vertical surface /skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed. |
| 42 | M&Lfor glazed ceramic coloured tiles450 x 300 x 7 mm thick on vertical surface such as dado / skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed.Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment. |
| 43 | M&L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate), 75mm thick in plinth protection and footpath laid in panels and finished even and smooth without using extra cement including necessary form work complete all as specified and directed. Note : Joints 12mm wide to the full depth of PCC shall be provided at every 3 meters and at every change of direction and shall be filled with mixture of bitumen and sand 1:3 by weight. Cost of this provision shall be deemed to be included in the quoted rate for concrete in plinth protection. |
| 44 | S&F Solid PVC door frame of size 50x47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube, supplied and fixed incl fixing of hold fast as per specification and drawing complete all as specified. |
| 45 | S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 4mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification with Wood free EPS complete all as specified. |
| 46 | S&F 150 mm long aluminium anodised barrel tower bolts complete all as specified and directed. |
| 47 | S&F aluminium handles 125 mm size cast type anodised complete all as specified. |
| 48 | S&F 75 mm size butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 49 | S&F pressed steel frames of size 125 mm x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc including one shop coat of priming complete all as specified and directed. |
| 50 | M&L for providing plain cement concrete (1:3:6) type C-1, (using 20 mm graded stone aggregate), as in copings, bed block for filing hollow space of steel chowkhats, fixing of hold fast, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. |
| 51 | S&F 30mm thick flush shutter, solid core construction, with block board core and plywood face panel, commercial type on both side etc complete all as specified and directed. |
| 52 | Supply and fixing of factory made partly glazed three panels i.e. upper panel will be wire mesh and further divided into two panels fitted externally in the clear space & lower panel will be plain colour PVC sheet 5mm thick PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail,; Paneling of plain colour PVC sheet to be fitted in the M.S.frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as per specified and as directed. |
| 53 | S&F 140 mm size floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 54 | S&F 100 mm size butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 55 | S&F aluminium anodised barrel tower bolts of extruded section 200 mm long all as specified and directed. |
| 56 | S&F aluminium handles 150mm size cast type anodised complete all as specified and directed. |
| 57 | S&F aluminium anodised, Sliding door bolt of 300mm long, fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 58 | S&F Powder coatedaluminium window sliding type three track (2 glazed & one gauze shutter ) aluminium sections weighing not less than 1.67kg/m for frame and 0.55 kg/m for shutter including necessary jointing cleats, glazingcleats, rubber packing , screws, handle, locking arrangement and 4 mm thick plain/tinted glass and aluminium mosquito proof gauge including taking down of old existing steel window and making good disturbed surface of wall complete all as specified and as directed. |
| 59 | S&F Powder coated aluminium louvered ventilators of size n exc 0.50 Sqm area with glass louvers, without sash bars of aluminium sections weighing not less than 0.605kg/m for frame of size 40x20x2mm including necessary jointing cleats, glazingcleats, rubber packing , anodised aluminium snap beading,screws, anodised aluminium fittings and 5.5mm thick tinted glass fixed in panels with suitable locking arrangementsincluding taking down of old existing steel ventilator and making good disturbed surface of wall complete all as specified and as directed. |
| 60 | S&F in repair stainless steel curtain rods 20-25 mm dia, anodised aluminium alloy with fixing brackets, stops, and complete fitments all as specified and directed. |
| 61 | S&F in repair MS 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed. |
| 62 | S&F Ball catches with 8mm dia steelball, and brass body and striking plate including letting in complete all as specified and as directed. |
| 63 | S&F stainless steel wire cloth 0.36 nominal dia wire & average width of aperature 1.40 mm fixed with stainless steel wire staples complete all as specified and directed. |
| 64 | M&L for preparation of new wooden surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as Specified. |
| 65 | S&F in repairs vitreous china wash basin, white, flat back, size550x400m excluding taps, waste, including chain & plug & porcelain stopper, brackets, cutting for pinning in ends of bracketes or erecting standand fixing and supply and waste pipe complete all as specified and directed |
| 66 | S&F15 mm fancytype swan neck pillar taps, cast copper alloy with capston heads, chromium plated, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe 15mm bore.(Make : ESSCO/Marc/Cera). |
| 67 | S&F in repairCP toilet paper holder with flat recessed type stainless steelcomplete all asspecified and as directed. |
| 68 | S&F in repairs 600mm x 450 mm bevelled edge mirrorof selected quality, mounted on 6 mm thick AC plain building board and fixed to wall on wooden plugs with chromium plated brass screws and cup washers all complete as specified and as directed. (Make :ATUL / MODI GUARD / SAINT GOBAIN). |
| 69 | S&F in repair 10 ltr capacity dual type PVC flushing cistern low level white colour incl PVC connection PVC flush pipe of reqd length complete all as specified and directed. |
| 70 | S&F in repair vitreous china wash down water closet pan (pedestal pattern), white including connection trap and to flushing pipe, anti-syphnoge pipe etc complete |
| 71 | S&F in repair PVC seat cover for pedestal pan, white closed pattern with flat bottom and cover and mild steel chromium plated or aluminiumisedhanging device complete all as directed. |
| 72 | S&F in repairs Bib taps long body fancy type cast copper alloy, chromium plated for 15mm bore pipe, screwed for iron pipes or for brass ferrule all complete as specified and as dierected. (Make : ESSCO/Marc/Cera). |
| 73 | S&F in repairs stop valves fancy type cast copper alloy, chromium plated with long shank and cup (concealed type) for 15mm bore pipe, screwed both ends including necessary fittings such as sockets for pipe or for union all complete as specified and as directed. (Make : ESSCO/Marc/Cera). |
| 74 | S&F 20mm bore Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all complete as specified and as directed. (Make : ESSCO/Marc/Zoloto). |
| 75 | S&F in repair 15mm bore PVC Connection with PTMT nut of length 600 mm complete all as specified and directed |
| 76 | S&F in repair 15 mm bore two way bip taps CPwith flage complete all as specified and direcrted. (Make : ESSCO/Marc/Cera). |
| 77 | S&F in repair 15 mm boreangle cock CPwith flage complete all as specified and direcrted (Make : ESSCO/Marc/Cera). |
| 78 | S&F in repairCP health faucet (ABS body)mild steel chromium plated suitable for 15 mm dia pipe with 1.25 m long flexible tube and ABS wall hook in cluding making connections and fixed in position complete in all respect and specified (Make : ESSCO/Marc/Cera). |
| 79 | S&F in repair for brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges. (Make : ESSCO/Marc/Cera). |
| 80 | S&F Soap dish, vitreous China white of approximate size 160 x 160 x 90 mmembeded in the wall all as specified and directed. |
| 81 | S&F in repair PTMT towel ring complete all as specified and directed. |
| 82 | S&F in repair swivel shower of CP with shower arm 150 mm size for fixing with 15 mm bore GI pipe complete all as specified and as directed(Make : ESSCO/Marc/Cera). |
| 83 | S&F sheet glass shelf assembly consisiting of 5.5 mm thick sheet glass shelf 12mm wide with CP brass bracket guard railing 60cm long, complete all as specified. |
| 84 | Dismantling water tanks and removing to store of capacity exc 500 & n.exc 1000 ltrs. |
| 85 | S&F 1000 ltrs capacity rotational moulded polyethelene water storage tanks (cyclindrical vertical with closed top) double layered ISI marked incl connecting up pipes securing access covers etc as specified and as directed. |
| 86 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc.complete all as specified. |
| 87 | M&L for 20 mm thick granite(of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified. |
| 88 | S&F GI tubes medium grade with all fittings fixed to walls and ceilings or laid in floors of 15 mm bore of pipe complete all as specified and directed. |
| 89 | S&F GI tubes medium grade with all fittings laid in trenches of 20 mm bore of pipe complete all as specified and directed. |
| 90 | Taking down eaves gutter, rain water pipes, CI/ PVC/ AC soil pipe with fittings from wall, treches of any description including fittings. |
| 91 | S&F PVC (SWR) pipessingle socketed, in any length with rubber ring joints, laid in trenches or in floors of 75 mm bore of pipe etc complete all as specified and directed. |
| 92 | S&F PVC (SWR) pipessingle socketed, in any length with rubber ring joints, laid in trenches or in floors of 110 mm bore of pipe etc complete all as specified and directed. |
| 93 | S&F PVC (SWR) bends any radius of 75 mm borewithoutaccess door complete all as specified and directed. |
| 94 | S&F PVC (SWR) branch pieces/junction single, (single Y/T) equal or un equal of 110 mm bore of pipewith access door complete all as specified and directed |
| 95 | S&F PVC (SWR) bends any radius of 110 mm bore complete all as specified and directed. |
| 96 | S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed. |
| 97 | S&F PVC (SWR) floor trap, plain with grating including jointing with solvent cement outer dia 75 mm cement concrete (1:2:4), type B1 including complete all as specified and as directed. |
| 98 | M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2 M dia X 1.5 M effective depth Complete all as specified and as directed |
| 99 | Dismantling wrought iron or mild steel work of any description complete all as specified and as directed. |
| 100 | S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings,frame work of watertanks and similar work conforming toFe -290 Gde E-165 complete all as specified and directed. |
| 101 | M&L for two coats of synthetic enamel paint over a coat of red oxide on new steel surfaces of any description over 10cm in width or girthincl preparation of surfaces complete all as specified and as directed. |
| 102 | Material and labour for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in surface channels and drains complete all as specified and as directed. |
| 103 | M&L for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand. |
| 104 | S&F PVC (SWR) 110 mm dia vent cowl complete all as specified and directed. |
| 105 | S&F 150mm bore reinforced concrete pipes, class NP2, laid and jointed complete with collars all as specified and directed. |
| 106 | M&L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested dia of pipe 150 mm complete all as specified and directed. |
| 107 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, poles, stays, cables etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed. |
| 108 | M&L for PCC (1:3:6) type C2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 109 | Returning, filing in, including spreading, levelling, watering and well rammingin layers not exceeding 25 cm thick in any type of soil etc complete all as specified and directed. |
| 110 | Removal of excavated materials not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed. |
| 111 | Demolition reinforced cement concrete of any description and in any position such as precast manhole cover slab or septic tank cover slab etc complete all as specified. |
| 112 | M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-l smooth finished, and reforming benching as required dia of pipe 150 mm complete all as specified and directed. |
| 113 | Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed. |
| 114 | M&L for point wiring complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sundn terminal box made out of GI sheet steel not less than 1.63mm thick for boxes upto a size of 200 x 300mm and above this size not less than 1.63 mm thick duly painted with aluminum inside and anticorrosive paint outside, concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications.Connections of cable with MCBs or bus bar shall be done through proper size copper/brass thimbles. Where concealing of conduit is not feasible ie on surface of roof etc, conduit shall be fixed on surface with necessary saddles at no extra cost all as specified and as directed for the following :- |
| 115 | One light point controlled by one, one way switch 5/6 amps. |
| 116 | One ceiling fan/ Exhaut fan point controlled by one, one way switch 5/6 amps. |
| 117 | One socket outlet 5/6 amps point on the independent board |
| 118 | One socket outlet 5/6 amps point on the same board |
| 119 | Ditto all as per serial item No 114.00 described here-in-before but wiring with 2.5 sqmm single core copper conductor for one socket outlet 15/16 amps point on the independent board complete all as specified and directed. |
| 120 | S&F switch piano flush type 5/6 amps single pole one way complete all as specified and directed. |
| 121 | S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flush type complete all as specified and directed. |
| 122 | S&F socket outlet 2 in 1, 5 Pin, 5/15 amp,multipurpose 230 volt flush type complete all as specified and directed. |
| 123 | S&F switch piano flush type 15/16 amps single pole one way complete all as specified and directed. |
| 124 | S&F deluxe fan electronic regulator 120/180volts AC 50 Hzs rotary step white/ivory finish complete all as specified and directed. |
| 125 | S&F ceiling rose, bakelite, surface type, 220/240 volts, three terminal /PVC/ polycarbonate, isolated body complete all as specified and directed. |
| 126 | S&F lamp holder, isolated body, with back plate suitable for batten/ angle fittings complete all as specified and directed. |
| 127 | S&F wall monted slim LED batten 20W 4\" long, min output 120 Lumen/ watt PF>0.95, surge protection,> 4KV, THD:<10% with extruded aluminium housing, with integrated LED driver complete all as specified and directed. |
| 128 | S&F LED luminaire 600 mm x 600 mm, 35/36 watt, min 110 Lumen/ watt PF>0.95 surge protection>4 KV, THD:<10% with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 129 | S&F LED street light fittins 35 watt min output 110 Lumen/ watt PF>0.95, surge protection>5 ,THD: <10%in aluminium PDC housing, toughned glass cover with IP66 protection complete all as spedified and as directed. |
| 130 | S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), single door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCBs/ lsolators complete including taking down the old one complete all as specified and directed. |
| 131 | S&F MCB, triple pole & neutral 63 amps, 415 volts, ‘C’ curve, 10 KA including taking down the old one complete all as specified and directed. |
| 132 | S&F MCB, Single pole & neutral 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA including taking down the old one complete all as specified and directed. |
| 133 | S&F MCB, Single pole, 6 to32 amps, 240 volts, ‘C’ curve, 10 KA including taking down the old one complete all as specified and directed. |
| 134 | Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. complete all as specified and directed. |
| 135 | M&L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/ loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and saltPCC pit (1:3:6) type C1( using 20mm graded stone aggregate) and 50mm thick RCC (1:2:4) type B0 (using 20mm graded stone aggregate) cover reinforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No. 3 of SSR part-1 and connected to the earth point and testing complete including taking out the old one complete all as specified and directed. |
| 136 | M&L for sub main wiring concealed type with two run single core cable PVC insulated cable with6.0Sqmm (Nominal area) multi stranded copper conductor FRLS cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of multistranded copper conductor of size 6.0 Sqmm connected to common earth dolly anddrawing into rigidPVC conduit of size 25 mm medium gradesize,making good the disturbed surfacescomplete including taking down old submain wiring. (NOTE : Two run of submain wiring cable alongwith one run of earth wire and PCV conduit shall be measured as one length.complete all as spedified and as directed. |
| 137 | M&L forstreet light bracket, made out of GI pipe (light grade) 25mm bore, 1.2 m long bend to shape and fixing/ grouting with wall using 2 Nos 25 x 5 mm size MS FI clamps with bolts, nuts & washers complete including drilling as necessary and two coats ofAluminium paint over a coat of Red oxide primer all as specified & directed. |
| 138 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 4 core all fixing and connecting accessories such as cable lugs, cable glands, nut, bolts, etc complete all as specified and as directed. |
| 139 | M&L for sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed by Engr-in-Charge. Note:- Punned down thickness 18 cm shall be considered for payment as per para 19.75 of SSR Part-I |
| 140 | Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trenchcomplete all as specified and directed. |
| 141 | S&F 40mm dia GI tubing medium grade ISI marked laid in trenches / laid under floor for protection of cable including all fittings such as elbow, bends, etc and short length complete all as specified and as directed. |