| 1 | Supply and fix as in repair BIS certified pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.55 mm of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed.Note:The contractor shall produce necessary Manufacturer test certificate for TCT and MCT to the Engineer-In-Charge for future reference. |
| 2 | Supply and fix as in repair BIS certified pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.55 mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed.Note:The contractor shall produce necessary Manufacturer test certificate for TCT and MCT to the Engineer-In-Charge for future reference. |
| 3 | Supply and fix as in repair roof truss (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to Fe-410W (Gde-E- 250) quality-A including cutting, welding & necessary fittings such as nut, bolts, plates etc. complete all as specified and directed.Note:During payment of RAR the contractor shall produce necessary Manufacturer test certificate for grade of structural steel. Under graded and under weighted material shall not be paid. Without production of MTC no RAR/ Bill will be paid. |
| 4 | Supply and fix as in repair suspended false ceiling using grid 180 GSM (exposed ceiling suspension system ) of grid size 605 mm x 605 mm with main runner 38 mm x 24 mm and wall angle 24 mm x 24 mm using 10 mm thick PVC laminated decorative Board in a grid of powder coated GI system duly suspended with 6 mmdia GI bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc. The main runners to be secured to structural soffits by hanger @ 1210 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450 mm from the adjacent wall, Flush fitting 1210 mm cross tee to be interlocked between main runners @ 605 mm c/c,so as to form 600 mm x 600 mm grid complete all as specified . Note: (a) Colour and pattern shall be approved by GE after physical verification(b) The runner and wall angles will be seamless type. |
| 5 | Demolition of existing roof padding including roof treatment complete carefully by cutting, chiselling etc cleaning the surfaces by scrapping, booming brushing etc and removing the rubbish from site to a distance exc 50m and n.exc 100m all as directed by the Engineer-in-Charge and M&L for applying roof treatment as under :-(i)30 mm thick plain cement concrete 1:2:4 type B1 using 20 mm graded crushed stone aggregates as in levelling course/ roof padding complete(ii) Providing 10mm thick (average) rendering in cement mortar 1:3 mixed with WPC as per manufacture\"s instruction (to be measured and paid including this item) for levelling to a true surface and to receive new roof treatment complete.(iii) Providing coat of bitumen primer @ 0.40 Kg/Sqm complete .(iv) Providing coat of hot blown bitumen of grade 85/25 @ 1.2 Kg/Sqm over primer surfaces alongwith aluminium paint @ 0.11 Kg/Sqm over the APP.(v) Providing a layer of APP based polymeric membrance of approved manufacturer, 3mm thick reinforced with polyester non wooven fabrix (weighing not less than 150 gm/ Sqm) laid by torch application method, side overlaps shall be minimum 75mm and end laps shall be minimum 100 mm and sealing all overlaps and joints as manufacturer\"s insructions and provided upto a height of 60 cm in the parapets and inserted inside the parapets by cutting a groove and finished by membrane flashing complete all as directed.Make of APP Membrane: M/S BENGAL BITUMEN/ M/S SIKA INDIA PVT LTD/ M/S FOSROC CHEMICALS/ M/S STP LTD |
| 6 | Supply and fix as in repairs vitreous china squatting pan of Orrisa pattern size 580 mm x 440 mm, white, with integral foot rests including 10 ltr flushing cistern, flush pipe and \"P\" or \"S\" trap and lime concrete bedding connection making good to floor all as specified. Make ParrywareCat No C0117* / Cera Cat No COVY S3010104/ Johnshon Cat No P0461PW |
| 7 | Supply, lay and fix as in repair 15 mm bore galvanized iron water tubing medium grade including all fittings and fixed complete to walls and ceiling or laid in floors all as specified.Make: Surya Roshni ltd/ Tata/ Jindal Steel/ Prakash/ Bansal/ Zenith/ Nezone Tubes Ltd |
| 8 | Supply, lay and fix as in repair 20 mm bore galvanized iron water tubing medium grade including all fittings and fixed complete to walls and ceiling or laid in floors all as specified.Make: Surya Roshni ltd/ Tata/ Jindal Steel/ Prakash/ Bansal/ Zenith/ Nezone Tubes Ltd |
| 9 | Material and labour for 7 to 8 mm thick joint free premium quality double charged anti skid colour ceramic tiles size of each tiles should be 600 mm x 600 mm as in floors set and jointed and pointed in white or colour cement to match existing surfaces including 20 mm thick screed bed in cement mortar 1:4 inclusive dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified.Make: Somani Ceramic Ltd/ Kajaria Ceramic Ltd/ Varmora Granito Pvt Ltd./ H&R Johnson India/ Orient Bell/ Nitco/ AGLNote: (i) The colour, shade and quality of tiles shall be approved after physical verification of GE.(ii) The manufacturer test certificate for double charged tile for consignment of manufacturing alongwith Purchase Voucher shall be produced by the contractor to the Engineer-In-Charge for future reference. |
| 10 | Material and labour for joint free premium quality double charged glazed ceramic colourtiles of size 600x300x7mm/ 450x300x7mm thick as in skirting / dado and in vertical surfaces set and jointed and pointed in white or colour cement to match existing surfaces including 10 mm thick rendering in cement mortar 1:3 inclusive dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified. Make: Somani Ceramic Ltd/ Kajaria Ceramic Ltd/ Varmora Granito Pvt Ltd./ H&R Johnson India/ Orient Bell/ Nitco/AGLNote: (i) The colour, shade and quality of tiles shall be approved after physical verification of GE.(ii) The manufacturer test certificate for double charged tile for consignment of manufacturing alongwith Purchase Voucher shall be produced by the contractor to the Engineer-In-Charge for future reference. |
| 11 | Supply and fix as in repairs white vitreous china counter shank wash basin ,including 32 mm dia chromium plated waste coupling and waste pipe, cutting for and pinning in ends of brackets or erecting stand complete all as per manufacturer instruction including taking out old existing basin including all fixtureres.Make Johnshon Cat No P1614PW0301/ Cera Cat No S2030115/ Parryware Cat No C0431 |
| 12 | Supply and fix as in repairs 110mm dia PVC (SWR) pipes single socketed in any length with rubber ringjoints fixed to walls with PVC clamps complete all as specified.Make: Jain Irrigation/ Kisan/ Supreme/ Prince/ Reliance/ OriplastNote: Quoted rate is deemed to be included for necessary Bend, Junction, branch piece, reducer and any other fittings required for fixing. |
| 13 | Supply and fix as in repairs 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ringjoints fixed to walls with PVC clamps complete all as specified.Make: Jain Irrigation/ Kisan/ Supreme/ Prince/ Reliance/ OriplastNote: Quoted rate is deemed to be included for necessary Bend, Junction, branch piece, reducer and any other fittings required for fixing. |
| 14 | Supply and fix as in repairs 75mm dia PVC (SWR) floor trap, plain with gratings including jointing to waste pipe fixed in cement concrete 1:2:4 type B0 using 12.50 mm graded crushed stone aggregates complete all as specified and directed.Make: Jain Irrigation/ Kisan/ Supreme/ Prince/ Reliance/ Oriplast |
| 15 | Supply and fix as in repairs 15 mm bore CP pillar tap,pressmatic with aerator complete as per manufacturer instruction.Make:- Jaquar Cat No PRS-031/ Johnson Cat No T2001C/ Cera Cat No F9020101 |
| 16 | Supply and fix 15 mm bore quarter turn Bib taps, chromium plated, cast copper alloy, with wall flange concealed type screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified.Make JohshonCat No T3305C/ Jaquar Cat No FUS-29037/ Marc Cat No MCT-1030 |
| 17 | Supply and fix as in repairs15 mm dia cast copper alloy chromium plated Angle valves, with wall flange concealed type screwed down for iron pipe of for unions complete all as specified and directed. Make :- ParrywareCat No T3907A1/ Cera Cat No F1016201/ Johnson Cat No T5310C |
| 18 | Supply and fix vitreous China urinals, with sensor flushing valve for urinal with complete kit, with all fixing accessories as per manufacturer instruction, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including brass screws, pointing around urinal back in cement including taking out existing urinal with all taps and fixtures.Make of Urinal: JaquarCat No URS-WHT-13255 / Parryware Cat No C0586/ Cera Cat No S4020107Make of Sensor Flushing Valve: JaquarCat No URS-WHT-0704/ Parryware Cat No C05901C/ Cera Cat No B2050104 |
| 19 | Supply and fix as in repairs 600 mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 12 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified.Make: Jaquar & Company Private Limited. / Cera/ Saint Gobain/ Modiguard/ Prayag Polymer Pvt. Ltd. |
| 20 | Supply and fix as in repairs 10 ltrs capacity PVC valveless syphonic action type, low level flushing cistern, white with inlet, ball valve float and handle including brackets and 32 mm dia PVC low or high density flush pipe complete all as per manufacturer instructionMake ParrywareCat No E8109 / Cera Cat NoB1020101/ Johnshon Cat No P2831PW |
| 21 | Supply and fix as in repair 30 mm thick factroy made solid panel PVC door shutter(style) consisting of frame made out of MS tube for top and bottom rails MS frame shall be covered with neat moulded plain colour PVC channel having a PVC sheet strip of 20mm width stuct inside the solvent cement forstyle and single side pre laminatedPVC sheet for top rails, lock rails and bottom rails on either side and as gap insert for top railsand bottom rail panelling of plain colour PVC sheet to be fitted in the MS frame welded to the style and rails with suitable PVC sheet beading and jointed together with solvent cement supplying and fixing in the frame of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube at site as per specificationincluding 02 nos of 125 mm long aluminium anodised handle both side of each shutter, 02 nos of 75 mm long aluminium anodised tower bolt both side of each shutter and 03 nos 100 mm size stainless steel butt hinges fixed to each shutter complete all as directed by Engineer-In-Charge.Note: (a) The frame and shutter shall be measured to a unit.(b) Contractor shall produce necessary Manufacturer Test Cretificate to the Engineer-In-Charge for future reference.(c) Colour and type shall be approved by GE after physical verification. |
| 22 | Material and labour for 10 mm thick renderingin cement mortar 1:6 on fair faces of brick wall or concrete surfaces, finished the surfaces even and smooth without using extra cement including taking down of cement plaster and preparation of old surfaces by brushing with steel brush and hacking the surface for applying new plaster after completing the rendering work preparation of newly plastered surfaces applying distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre of approved manufacturer of required shade and colour complete using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface with using auto roller for making the surface uniform over Two or more coats over a coat of wall care putty and finished by mechanically complete all as specified and directed.Note : - (a) Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. Proper mashking to be carried out before primer and paint application. complete all as specified. |
| 23 | Material and labour for 5 mm thick renderingin cement mortar 1:3 on fair faces of ceiling surfaces, finished the surfaces even and smooth without using extra cement including taking down of cement plaster and preparation of old surfaces by brushing with steel brush and hacking the surface for applying new plaster after completing the rendering work preparation of newly plastered surfaces applying distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre of approved manufacturer of required shade and colour complete using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface with using auto roller for making the surface uniform over Two or more coats over a coat of putty and finished by mechanically complete all as specified and directed.Note : - (a) Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. Proper mashking to be carried out before primer and paint application. complete all as specified. |
| 24 | Material and labour for 15 mm thick renderingin cement mortar 1:4 in two layers (10 mm +5 mm) on external faces of brick wall or concrete surfaces, finished the surfaces even and smooth without using extra cement with using approved LWPC on second layer (5 mm) as per manufacturer instruction including taking down of cement plaster and preparation of old surfaces by brushing with steel brush and hacking the surface for applying new plaster including preparation of new plastered surface and applying two coat water based premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI.Allow 6-8 hrs to dry the surface in both the coats of paint with using auto roller for making the surface uniform complete all as directed. complete all as specified. Note: (a) Liquid Water Proofing Compound shall be measured and paid including this item |
| 25 | Additional Notes for BOQ SL No 22 to 24 (a.) The prepatory and application work pertaining to periodical services & Water Proofing shall be executed from authorized applicator duly certified by manufacturer of the Paint, Distemper, Putty etc. Before execution of work necessary approval shall be taken from Garrison Engineer with all documentary evidances. (b) Necessary scaffolding and ladder of approx. 10 m height shall be provided by the contractor in his own arrangement. Green cloth shall be provided all around the work site for any position/ height with all safety precaution (i.e Safety Jacket, Safety Shoes, Safety Masks, Safety Helmet, Safety harness, Safety Goggles etc.) Without safety precaution this work not been commenced as decided by Engineer-In-Charge/ by Garrison Engineer. No extra cost shall be paid for such precaution. Such precaution shall be deemed to be included in the quoted rate.(c.) The contractor shall upload along with the documents under cover-I (i.e Technical Bid), ‘Memorandum of Understanding’ (MOU) duly notarised not later than 03 months with only one manufacturer mentioned in the Contract Agreement, failing which the bid shall be liable to be rejected and Cover-II ( i.e. Financial bid) will not be opened. Validity of MOU shall be valid during the currency of the work.During currency of the work only those worker shall be worked at site who will be duly cerified by the Manufacturer. Both side affidavit of Rs/- 10 stamp paper i.e. from the side of Manufacturer and from the side of worker shall be provided during the currency of work.(d) Insurance for each worker shall be provided during currency of the work and no extra cost shall be paid. The same shall be deemed to be included in the quoted rate.(e) No work shall be commenced without furnishing above documents to the concerned authority. (f) Masking of window/doors during spray painting using polythine film shall be deemed to be included in the quoted rate.(g) No payment for additional height shall be paid to the contactor.(h) Cleaning and clearing site of paint, mats etc. are deemed to be included in the quoted rate. No completion will be issued without proper cleaning of site as per direction of Garrison Engineer or by the Engineer-In-Charge. |
| 26 | Material and labour for preparation old plastered or unplastered wall surfaces including brooming down or steel wire brushing , scrapping down smoke, soot , moulds , moss and efflorescent salts and trading oil and greasy spots etcand and applying distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre of approved manufacturer of required shade and colour complete, as per manufacturer\"s specification. One or more coats over a coat of wall care putty complete all as directed.Make: Berger (Silk)/ Dulux (Velvet Touch)/ Shalimar Paints Ltd (Superlac Stay clean)/ Asian Paints Ltd, (Royal Aspira)/ Nerrolac Paints Ltd (Impression) |
| 27 | Material and labour for preparation old plastered or unplastered ceiling surfaces including brooming down or steel wire brushing , scrapping down smoke, soot , moulds , moss and efflorescent salts and trading oil and greasy spots etcand and applying distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre of approved manufacturer of required shade and colour complete, as per manufacturer\"s specification. One or more coats over a coat of putty complete all as directed.Make: Berger (Silk)/ Dulux (Velvet Touch)/ Shalimar Paints Ltd (Superlac Stay clean)/ Asian Paints Ltd, (Royal Aspira)/ Nerrolac Paints Ltd (Impression) |
| 28 | Material and labour for complete removal of existing wall surfaces for applying two or more coatsof 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS-15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm over wall surfaces complete all as specified and as directed.Make: Berger (Silk)/ Dulux (Velvet Touch)/ Shalimar Paints Ltd (Superlac Stay clean)/ Asian Paints Ltd, (Royal Aspira)/ Nerrolac Paints Ltd (Impression) |
| 29 | Supply and fix as in repairs Rotational moulded polyethylene water storage overhead tanks (cylindrical vertical with closed top) multi layered 2000 ltr capacity hoisted and fixed in position including25 mm dia Ball valves (Minimum weight of valve 455 gms) high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe complete all as specified.Make:Sintex/ Astral/ Finolex/ Supreme |
| 30 | Taking down chowkhats with shutters (without taking off shutters from the frames) & removing from site area exc 1.5 Sqm & n. exc 4.00 sqm each complete all as directed. |
| 31 | Supply and fix Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe-410W Grade E-250 (quality A) complete all as specified.Note:During payment of RAR the contractor shall produce necessary Manufacturer test certificate for grade of structural steel. Under graded and under weighted material shall not be paid. Without production of MTC no RAR/ Bill will be paid. |
| 32 | Supply and fix 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides is covered with decorative face veneer with lipping/frame to match complete all as specified. |
| 33 | Supply and fix 125 mm long stainless steel, Butt hinges with MS hinge pins complete all as specified. |
| 34 | Supply and fix 150 mm long aluminium anodised barrel tower bolts of extruded section all as specified. |
| 35 | Supply and fix 150 mm long aluminium alloy handles, fabricated type, anodized all as specified. |
| 36 | Supply and fix 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified. |
| 37 | Material and labour for prepration new or previously untreated wood or wood base materials of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified. |
| 38 | Material and labour for preparation of old painted wooden surfaces of any description exceeding 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified. |
| 39 | Supply and fix,3 ways sliding anodized aluminium powder coated (of minimum powder coating 50 micron) glazed window shutter with frame with the following specification (a) Frame 91.80 mm x 31.75 mm x 1.20 mm Thick (b) 35 mm x 35 x 1.5 mm Z section in stiles, rails(c) 35 mm x 35 mm x 1.5 mm T section mullion (d) one/ two shutter with PVC gasket with 4.80 mm thick tinted glass including black flim/ 4.80 mm thick frosted glass as per requirement properly fitted with shutter, including decorative type aluminium handles of size 200 mm with necessary locking arrangement as per manufacturer instruction and one shutter with stainless steel wire cloth. 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staples.Note: (i) Manufacturer test cetificate for MCT and TCT shall be produced to the Engineer-in-Charge for future reference.(ii) The gap between wall and frame shall be properly filled by putty.(iii) The weight of wire cloth shall be minimum 3.97 Kg/ Sqm. (iv) Holdfast concreting with 1:3:6 type C0 using 12.50 mm crushed stone aggregates shall be measured and paid including this item |
| 40 | Supply and fix as in repair Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified.Note:During payment of RAR the contractor shall produce necessary Manufacturer test certificate for grade of structural steel. Under graded and under weighted material shall not be paid. Without production of MTC no RAR/ Bill will be paid. |
| 41 | Material and labour for preparation of new and previously untreated steel or ironsurfaces of any description, not otherwise described exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over one coat ofred oxideprimer all as specified. |
| 42 | Supply and fix powder coated aluminium window and ventilator shutters powder coating of any colour (Thickness or powder coating not less than 50 micron), side hung/ sliding type without sash bars, aluminium sections weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified.Note: (i) Manufacturer test cetificate for MCT and TCT shall be produced to the Engineer-in-Charge for future reference.(ii) The gap between wall and frame shall be properly filled by putty.(iii) Holdfast concreting with 1:3:6 type C0 using 12.50 mm crushed stone aggregates shall be measured and paid including this item |
| 43 | Material and labour for anodised aluminium doorand chowkhatsmade out of hollow extruded aluminium section as mentioned below. Each door shall beprovided with 02 Nos disc or Dtype aluminium handles, 02 Nos aluminium tower bolts 200 mm long, one brass mortice lock of six levers with key in duplicate and shallbe regulated by provided double action hydraulic floor doorspring/hydraulic door closer.Shutter to be glazed with andincluding 5.5 mm thick tinted glass, rubber beading/gasket, anodised aluminium beading, screws complete in all respect all as directed by the Engineer-in-charge.(a) Chowkhat/frame: 101.6 mm x 44.45 mm x 1.5mm thick(b) Shutter top and bottom rail: 114.3 mm x 44.45 mm x 1.5 mm thick(c) Shutter middle rail : 83.5 mm x 44.45 mm x 1.5 mm thick(d) Shutter vertical/style : 83.5 mm x 44.45 mm x 1.5 mm thickMAKE : (i) Anodised aluminium section : JINDAL/ HINDALCO/ INDALCO(ii)Glass : Saint Gobin/ Modi Guard/ TATA. |
| 44 | Taking down carefully aluminium/copper point wiring (light,fan,socket or power) of any type complete, including fixtures and fittings such as switches,ceiling roses,pendants,regulators sockets, light fittings etc. removing materials to stores for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls,floors,ceiling etc.,all as directed |
| 45 | Material and labour for point wiring with 1.50 Sqmm PVC insulatedun sheatned multi stranded copper conductor cable (FRLSH) 1100 volts grade two single core conforming to IS-694-1990 and one run of continious earth wire with 1.50 Sqmm PVC insulated unsheatned stranded copper conductor cable (FRLSH) draw in and including heavy duty 20 mm dia PVCconduit(ISI marked) in concealed with all necessaryfittings and fixures and switch, socket, regulator, fan point, exhaust fan point etc. including making good disturbed surface with CM (1:4) to match with the existing surface complete all as specified for the following :- Note:-(a) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing.Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.(b) Quoted rates shall be deemed for conduit,cutting chases of wall, making good disturbed wall.(c) The metal flush box with modular cover plates with frame measured and paid separately.Make: Finolex(ISI Marked)/ Polycab(ISI Marked)/ Nicco (ISI Marked)/ Havells (ISI Marked)/ RR Cable(ISI Marked)/ KEI (ISI Marked) |
| 46 | One light/ fan point/ call bell/ exhaust fan controlled by one, one way switch |
| 47 | One light point controlled by one nos, two way switch |
| 48 | One 5 pin 6 Amps switch socket outlet point controlled by one switch on same board with other switches |
| 49 | One 5 pin 6 Amps switch socket outlet point controlled by one switch on independent board. |
| 50 | All as per Item No 44.00 but One socket outlet point 6 pin, 15 amps, independent, with cables 4.00 sq. mm size complete all as specified. |
| 51 | Supply and fix modular metal flush box with modular white cover plate with frame , 3 module complete all as specified.Make: L&T/ Legrand/ Havells/ Anchor/ Schneider/ Hager |
| 52 | Supply and fix modular metal flush box with modular white cover plate with frame , 4 module complete all as specified.Make: L&T/ Legrand/ Havells/ Anchor/ Schneider/ Hager |
| 53 | Supply and fix modular metal flush box with modular white cover plate with frame , 6 module complete all as specified.Make: L&T/ Legrand/ Havells/ Anchor/ Schneider/ Hager |
| 54 | Supply and fix modular metal flush box with modular white cover plate with frame , 8 module complete all as specified.Make: L&T/ Legrand/ Havells/ Anchor/ Schneider/ Hager |
| 55 | Supply and fix as in repairs Modular type Switch 1 module, flush type single pole one way 6 Amps 240V.Make: L&T/ Legrand/ Havells/ Anchor/ Schneider/ Hager |
| 56 | Supply and fix as in repairs Modular type Switch 1 module, flush type single pole one way 20 Amps 240V.Make: L&T/ Legrand/ Havells/ Anchor/ Schneider/ Hager |
| 57 | Supply and fix as in repairs Modular type Switch 1 module, flush type single pole two way 6 Amps 240V.Make: L&T/ Legrand/ Havells/ Anchor/ Schneider/ Hager |
| 58 | Supply and fix as in repairs socket outlet modular type 2 module , 2/3 pin 6 Amps 240 V flush type.Make: L&T/ Legrand/ Havells/ Anchor/ Schneider/ Hager |
| 59 | Supply and fix as in repairs Modular type socket 2 module, 2 in 1 (multipurpose), 6 pin 6 Amps and 16 Amps 240 V ,flush type.Make: L&T/ Legrand/ Havells/ Anchor/ Schneider/ Hager |
| 60 | Supply and fix as in repairs Modular bell push 1 module flush type 6 Amps.Make: L&T/ Legrand/ Havells/ Anchor/ Schneider/ Hager |
| 61 | Supply and fix as in repairs Moodular call bell ding dong type 1 module SP 230V.Make: L&T/ Legrand/ Havells/ Anchor/ Schneider/ Hager |
| 62 | Supply and fix as in repairs ceiling rose surface baklite with three terminals 240 V.Make: L&T/ Legrand/ Havells/ Anchor/ Schneider/ Hager |
| 63 | Supply and fix as in repairs fan regulator electronics modular type 230 V stepped type 120 Watt all as specified.Make: L&T/ Legrand/ Havells/ Anchor/ Schneider/ Hager |
| 64 | Supply and fixing sub-main wiring with PVC insulated & unsheathed two run of 10.00 Sqmm single core multistrand copper conductor cable (FRLSH), 1100 Volt grade alongwith single run of 10.00 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH) 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through minimum 32 mm PVC conduit including taking down existing wiring complete all as specified and directed.Note:- (a)PVC conduit in concealed including accessories shall be measured and paid including the item.(b) 2 Run of line conductor and 1 Run of earth continuity conductor shall be measured as one unit length.(c) Cable requireds for connection to MCBs/DBs shall be deemed to be included in the unit rate.(d) Rate shall be included for cutting, pinning in, making good to facings where required for pointing in cement mortar 1:3 and cutting chases for concealed conduit wiring and making good, and cutting not exceeding 10 cm girth.Make:Finolex(ISI Marked)/ Polycab(ISI Marked)/ Nicco (ISI Marked)/ Havells (ISI Marked)/ RR Cable(ISI Marked)/ KEI (ISI Marked) |
| 65 | Supply and fixing sub-main wiring with PVC insulated & unsheathed two run of 6.00 Sqmm single core multistrand copper conductor cable (FRLSH), 1100 Volt grade alongwith single run of 6.00 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH) 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through minimum 25 mm PVC conduit including taking down existing wiring complete all as specified and directed.Note:- (a)PVC conduit in concealed including accessories shall be measured and paid including the item.(b) 2 Run of line conductor and 1 Run of earth continuity conductor shall be measured as one unit length.(c) Cable requireds for connection to MCBs/DBs shall be deemed to be included in the unit rate.(d) Rate shall be included for cutting, pinning in, making good to facings where required for pointing in cement mortar 1:3 and cutting chases for concealed conduit wiring and making good, and cutting not exceeding 10 cm girth.Make:Finolex(ISI Marked)/ Polycab(ISI Marked)/ Nicco (ISI Marked)/ Havells (ISI Marked)/ RR Cable(ISI Marked)/ KEI (ISI Marked) |
| 66 | Supply and fixing sub-main wiring with PVC insulated & unsheathed two run of 4.00 Sqmm single core multistrand copper conductor cable (FRLSH), 1100 Volt grade alongwith single run of 4.00 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH) 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through minimum 25 mm PVC conduit including taking down existing wiring complete all as specified and directed.Note:- (a)PVC conduit in concealed including accessories shall be measured and paid including the item.(b) 2 Run of line conductor and 1 Run of earth continuity conductor shall be measured as one unit length.(c) Cable requireds for connection to MCBs/DBs shall be deemed to be included in the unit rate.(d) Rate shall be included for cutting, pinning in, making good to facings where required for pointing in cement mortar 1:3 and cutting chases for concealed conduit wiring and making good, and cutting not exceeding 10 cm girth.Make:Finolex(ISI Marked)/ Polycab(ISI Marked)/ Nicco (ISI Marked)/ Havells (ISI Marked)/ RR Cable(ISI Marked)/ KEI (ISI Marked) |
| 67 | Supply and fixing sub-main wiring with PVC insulated & unsheathed two run of 2.50 Sqmm single core multistrand copper conductor cable (FRLSH), 1100 Volt grade alongwith single run of 2.50 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH) 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through minimum 25 mm PVC conduit including taking down existing wiring complete all as specified and directed.Note:- (a)PVC conduit in concealed including accessories shall be measured and paid including the item.(b) 2 Run of line conductor and 1 Run of earth continuity conductor shall be measured as one unit length.(c) Cable requireds for connection to MCBs/DBs shall be deemed to be included in the unit rate.(d) Rate shall be included for cutting, pinning in, making good to facings where required for pointing in cement mortar 1:3 and cutting chases for concealed conduit wiring and making good, and cutting not exceeding 10 cm girth.Make:Finolex(ISI Marked)/ Polycab(ISI Marked)/ Nicco (ISI Marked)/ Havells (ISI Marked)/ RR Cable(ISI Marked)/ KEI (ISI Marked) |
| 68 | Supply and fix as in repairs 3 pin metal plug and socket complete with one single pole MCB \"C\" Series 20 Amps, 240 Volts complete all as directed.Make: ABB/ Siemens/ Schneider/ Legrand/ Hagger/ L&T/ GE |
| 69 | Supply and fix exhaust fan of 300 mm sweep,metal body,heavy duty, double ball bearing, 1400 RPM,70 watt, 4 blades, air delivery 1770 m3 /h, suitable for SP 230/250 Volts, 50 Hz AC supply complete with louver shutter including fixing/ grouting of frame & louvers in wall & connecting with and including 3 Nos 1.5 Sqmm single core, PVC insulated but unsheathed FRLS 1100 Volts grade cable with multistranded copper conductor from ceiling rose to fan complete all as directed.Make : Havells / Bajaj/ Crompton/Usha/Orient |
| 70 | Supply and fix 4\" 20W LED batten surface/ wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronics driver duly wired upto terminal block, power consumption<20W, luminarie lumen> 1000 lumen, system efficiency of> 100 lumens/W, LED with LED binning as per ANSI Bin C78.377A, photo biological safety report as IEC624718 & electrical insulation class 1, Ingress protection IP 2, colour rendering index CRI>80, temp range 0 to 450C, driver efficiency>85%, power factor>0.9, THD<20% as per IEC 61000-3-2, colour temp-6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level < 60V DC as per IEC standard with LM70 & LM80 certification.Make:- Crompton / Bajaj/ Philips/ Havells/ Osram/ Wipro/ GE |
| 71 | Supply and fixas in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC tri-colour (warm white, pure white and natural white) decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specifed and directed.Make:- Crompton / Bajaj/ Philips/ Havells/ Osram/ Wipro/ GE Note:- (a) LM-80 certificate from NABL accredited Lab shall be submitted for LED light fittings.(b) Warranty certificate shall be submitted for LED light fitting as per standered format for minium 50000 Hrs.(c) LED light fitting and drivers shall be of same make. |
| 72 | Supply and fixing as in replacement LED luminaire 600mm x 600mm square type 34 to 36 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three flexible copper conductor cases of suitable size complete all as directed.Note:- (a) LM-80 certificate from NABL accredited Lab shall be submitted for LED light fittings.(b) Warranty certificate shall be submitted for LED light fitting as per standered format for minimum 50000 Hrs.(c) LED light fitting and drivers shall be of same make. |
| 73 | Material and labour for earthing complete with galvanised earth plate 60 cm X 60 cm X 6.00 mm thick buried vertically in ground to depth not less than 2.25 metres deep below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to connected to galvanised earth lead wire 4.0mm dia by means by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe light grade 40mm bore for protection of earth wire and connected to continous earth lead on pole/test point, supplying and laying charcoal dust common salt PCC 1:2:4 type B1, chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI/CI funnel and wire mesh, 20mm dia GI pipe medium grade for watering all as shown in electrical plate No 5 on srl page No 497 of SSR Part I (2009)drawing and connection to earth test point including testing and including dismantling and taking out old earthing complete all as specified and directed.Note : (i) The cost of earth lead /strip and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate.(ii)The cost of excavation, earth work is included in the quoted rate. |
| 74 | Material and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire including taking out existing conductor complete all as specified and directed. |
| 75 | Supply and fix as in replacement LED Bldg security luminaire 35 W Aluminium PDC housing, toughened glass cover, IP 65 protection, pre-wired and including GI bracket, clamp, nut, bolts, etcof suitable size, connecting up with twin core twisted flexible copper conductor cable with suitable size all as directed.Make: Crompton / Bajaj/ Philips/ Havells/ Osram/ Wipro/ GE Note:- (a) LM-80 certificate from NABL accredited Lab shall be submitted for LED light fittings to the Engineer-In-Charge.(b) Warranty certificate shall be submitted for LED light fitting as per standered format for minimum 50000 Hrs to the Engineer-In-Charge.(c) LED light fitting and drivers shall be of same make. |
| 76 | Supply and fix MCCB V TPN DB 08 waySuitable for Flush Mounting and Surface MountingWith 200 A Copper Busbar for each phase with 2 Neutral bar, 2 Earthbar and Cable ties for Cable management Fully insulated busbar & shrouded Neutral bars improved Pan assembly for ease of installationPrefitted masking sheet Reversible Door IP 54 DB\"s With MCCB adjustable type thermal magnetic release type,4 poles, 415 Volts,Ics = 100% Icu, Lcu = 25 KA breaking capacity, rating 100 A including all fixing accessories with both ends spreader links as incomer andSP/DP MCB\"s as outgoing complete all as specified and directed.Make: ABB/ Siemens/ Schneider/ Legrand/ Hagger/ L&T/ GENote: (a) Quoted rates shall be deemed for brick wall / concrete wall cutting and making good as per existing surfaces.(b) MCCB shall be measured and paid including this item but MCB shall be measured and paid separately(c) Fixing of MCB shall be included under this item(d) Blank space shall be covered with blank plates and cost for same shall be deemed to be included under this item. |
| 77 | Supply and fix as in replacement MCCB 4 Pole 100 Amps confiming to IEC 60947-2 * IS 13947-3 thermal magnetic release and adjustable over load setting 0.8- 1.0 x In and adjustabgle short circuit setting 5-10 x In and rupturing capacity 16 KA at 415 V AC, 50 HzMake: ABB/ Siemens/ Schneider/ Legrand/ Hagger/ L&T/ GE |
| 78 | Supply and fix as in replacement sheet metal enclosure MCB DB TPN with din rail 04 way 240 V (double door type) with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonry etc. and making good of disturbed surface to match with existing colour of wall complete all as specified.Make: ABB/ Siemens/ Schneider/ Legrand/ Hagger/ L&T/ GENote: (a) Quoted rates shall be deemed for brick wall / concrete wall cutting and making good as per existing surfaces. |
| 79 | Supply and fix as in repair MCB TP 415 volts, 50 Hz capacity 63 Amps \"C\" curve all as specified.Make: ABB/ Siemens/ Schneider/ Legrand/ Hagger/ L&T/ GE |
| 80 | Supply and fix as in replacement sheet metal enclosure MCB DB SPN with din rail 08 way 240 V (double door type) with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonry etc. and making good of disturbed surface to match with existing colour of wall complete all as specified.Make: ABB/ Siemens/ Schneider/ Legrand/ Hagger/ L&T/ GENote: (a) Quoted rates shall be deemed for brick wall / concrete wall cutting and making good as per existing surfaces. |
| 81 | Supply and fix as in replacement sheet metal enclosure MCB DB SPN with din rail 04 way 240 V (double door type) with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonry etc. and making good of disturbed surface to match with existing colour of wall complete all as specified.Make: ABB/ Siemens/ Schneider/ Legrand/ Hagger/ L&T/ GENote: (a) Quoted rates shall be deemed for brick wall / concrete wall cutting and making good as per existing surfaces. |
| 82 | Supply and fix as in repair MCB SPN 240 volts, 50 Hz capacity 40 Amps \"C\" curve all as specified.Make: ABB/ Siemens/ Schneider/ Legrand/ Hagger/ L&T/ GE |
| 83 | Supply and fix as in repair MCB SP 240 volts, 50 Hz capacity 6-32 Amps \"C\" curve all as specified.Make: ABB/ Siemens/ Schneider/ Legrand/ Hagger/ L&T/ GE |
| 84 | Supply and fix as in repair MCB TPN/FP 415 volts, 50 Hz capacity 63 Amps \"C\" curve all as specified.Make: ABB/ Siemens/ Schneider/ Legrand/ Hagger/ L&T/ GE |