Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 25-12-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 30-12-2025 |
| 2 | 18-12-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 25-12-2025 |
| Sl. No. | Item Description |
| 1 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engineer-in-Charge. |
| 2 | M&L for providing pre-cast cement concrete landing, cover slabs (for man holes etc), chullah hoods, chajjas, water troughs, mangers, shelves and similar items with plain faces in cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregates) and setting in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge. |
| 3 | use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc. also splayes between floors and beams in rough finished flat surface of concrete complete all as specified and as directed by Engineer-in-Charge. |
| 4 | M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge. |
| 5 | M&L for mild steel TMT bars 6 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge. |
| 6 | Demolition of brickwork or stone boulder masonry built in cemnt mortar including all quions, arches pillars etc but excluding ashlar facings including removing debris from the site complete all as specified and as directed by Engineer-in-Charge. |
| 7 | M&L for Brick work built in CM (1:6) straight or curved on plan exceeding 6 metre mean radius using sub class \"B\" bricks (old size bricks) complete all as specified and as directed by Engineer-in-Charge. |
| 8 | Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thick above or below ground level complete all as specified and as directed by Engineer-in-Charge. |
| 9 | M&L for plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregates) as in foundation, filling and mass concrete complete all as specified and as directed by Engineer-in-Charge. |
| 10 | M&L for 75 mm thick cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregates) as in floors, plinth protection (finished even and fair) laid in panels including joints filled with sealing compound grade \"A\" complete all as specified and as directed by Engineer-in-Charge. |
| 11 | Providing and laying 80 mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50 mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paverblocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed by Engineer-in-Charge. |
| 12 | M&L for plain cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregates) as incopings and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and as directed by Engineer-in-Charge. |
| 13 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons laid, bedded and pointed in any mortar etc. complete all as specified and as directed by Engineer-in-Charge. |
| 14 | M&L for 18-20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window sills, cooking platforms and like in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge. |
| 15 | Extra over Granite or marble slabs as in rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations etc complete all as specified and as directed by Engineer-in-Charge. |
| 16 | M&L for Green Marble work 18 to 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window sills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed by Engineer-in-Charge. |
| 17 | S&F in repairs PVC wall panelling, hollow cored, 5 mm thick, decorative designs with smooth surfaces, fire resistant, water and heat proof, tongue and groove edge for easy assembly with all accessories such as U cap, end cap, tee, plugs, fillets and screws etc as per manufactures instructions and fixingcomplete all as specified and as directed by Engineer-in-Charge. |
| 18 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed by Engineer-in-Charge. |
| 19 | Excavating in post holes in soft/ loose soil (or similar holes) each not exceeding 0.5 CUM, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed by Engineer-in-Charge. |
| 20 | Steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240, including shop coat of zinc chrome red oxide primer complete all as specified and as directed by Engineer-in-Charge. |
| 21 | Supply and fixing mild steel screw bolt (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut not exceeding 5 cm long, diameter of shank/ neck 05-10 mm, complete all as specified and as directed by Engineer-in-charge. |
| 22 | S&F Mild steel works as in Plates (plain or chequered), channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment with Fe-410-W (Gde E-250) quality B complete all as specified and as directed by Engineer-in-Charge. |
| 23 | M&L for preparation of new steel surfaces of any descripetion over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces of any descriptionincluding preparation of surface complete all as specified and as directed by Engineer-in-Charge. |
| 24 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering including stacking properly for reuse complete all as specified and as directed by Engineer-in-Charge. |
| 25 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm of mangalore pattern of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-Charge. |
| 26 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in valley/ gutter/ eve board fixed with self tapping screws etc., ccomplete all as specified and as directed by Engineer-in-Charge. |
| 27 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets all as specified and directed by Engineer-in-Charge. |
| 28 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of semi perforated perforated 12 mm thickmicro tegular edged GRG false ceiling tiles of size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of mainT runners of size 15 x 32 mm of length 3000mm,cross-T of size 15 x 32mm of length 1200 mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600 x 600mm,Contd... |
| 29 | Contd…suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50 mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000 mm length and L shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24 x 24 x 0.40 mm of length 3000 mm to be fixed on periphery wall partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in Charge. |
| 30 | Taking down cement plaster of any description on brick or stone walls/ chipping off cement concrete in any situation etc. including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed by Engineer-in-Charge. |
| 31 | M&L for rendering 15 mm thick in CM 1:4 mixed with WPC at 3% by weight of cement on concrete wallsurfaces, finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.Note: (WPC to be measured and paid for separately) |
| 32 | M&L for Rendering 5 mm thick on ceiling surfaces in cement mortar 1:3 on fair faces of brick work or concrete surfaces and finishing the surface even and smooth complete all as specified and as directed by Engineer-in-Charge. |
| 33 | M&L for rendering 10 mm thick in CM 1:6 on concrete/ wall surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. |
| 34 | Supply only integral water proofing compound, ISI Marked, complete all as specified. |
| 35 | M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over 01 mm thick cement based wall putty complete all as specified and as directed by Engineer-in-Charge. |
| 36 | M&L for preparation of plastered or unplastered new decorated surfaces of ceiling and applying three coat of white lime wash complete all as specified and as directed by Engineer-in-Charge. |
| 37 | M&L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre / 10 sqm over 01mm thick water proof based wall puttyincluding preparation of new wall surface complete all as specified and directed |
| 38 | M&L for preparation of old treated surface of ceiling & applying one coat of white wash complete all as specified and as directed by Engineer-in-Charge. |
| 39 | M&L for preparation of old treated wood or wood based surface of any description exceeding 10 cm width or girth and applying one coat of synthetic enamel paintcomplete all as specified and as directed by Engineer-in-Charge. |
| 40 | M&L for complete removal of existing treatment of old surfaces of wall including cornices, pilasters and other wall features etc by washing, rubbing down and applying two coat of oil bound distemper over 01 mm thick cement based wall putty complete all as specified and as directed by Engineer-in-Charge. |
| 41 | M&L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less thatn 50 Gm/litre and UV resistance as per IS-15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre / 10 sqm over 01mm thick water proof based wall putty including preparation of surface by complete removal of existing treatment complete all as specified and directed |
| 42 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engineer-in-Charge. |
| 43 | M&L for 25 mm thick Cement Conrete 1:2:4, type B–0 (using 12.5 mm graded stone aggregates) as infloor finishes including finishing the surface even and rough to receive topping layer complete all as specified and as directed by Engineer-in-Charge. |
| 44 | M&L for Non-skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge. |
| 45 | M&L for Glazed digital designer, colored ceramic tiles of size 300 x 450 mm, 7mm thick, of concept pattern on vertical surfaces, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge. |
| 46 | M&L for double charged vitrified ceramic tiles, light shade, coloured with matt finish, 8-9 mm thick (square/ rectangular) polished, area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement paste pigmented to tile shade over and including 15 mm thick cement and sand screed bed in CM 1:6 complete all as specified and as directed by Engineer-in-Charge. |
| 47 | All as per Srl item No. 45.00 here-in-before but on vertical surface such as skirting, dado over and including 10 mm thick rendering in CM 1:4 etc complete all as specified and as directed by Engineer-in-Charge. |
| 48 | Dismantling of cast iron drain pipes 100 mm bore, with fittings, jointed in cement mortar and taking out of trenches complete all as specified and as directed by Engineer-in-Charge. |
| 49 | Dismantling of cast iron drain pipes 75 mm bore, with fittings, jointed in cement mortar and taking out of trenches complete all as specified and as directed by Engineer-in-Charge. |
| 50 | S&F PVC (SWR) soil or waste pipe, 110 mm bore, single socketed, in any length type \"B\" with rubber ring joints laid in trenches or floor/ wall complete all as specified and as directed by Engineer-in-Charge. |
| 51 | All as per Serial Item No. 49.00 here-in-before but 75 mm bore complete all as specified and as directed by Engineer-in-Charge. |
| 52 | S&F PVC (SWR) bends in any radius, 110 mm dia. complete all as specified and as directed by Engineer-in-Charge. |
| 53 | S&F PVC (SWR) bends in any radius, 75 mm dia. complete all as specified and as directed by Engineer-in-Charge. |
| 54 | Taking down chowkhats or frames of area not exceeding 1.5 Sqm each (without taking off shutters from the frame) complete all as specified and as directed by Engineer-in-Charge. |
| 55 | Taking down chowkhats or frames of area exceeding 1.5 Sqm but not exceeding 4.00 sqm each (without taking off shutters from the frame) complete all as specified and as directed by Engineer-in-Charge. |
| 56 | S&F 105 x 60 mm pressed steel frames 1.25 mm thick for doors, windows with one or more rebates incl necessary fixing hinges, lugs, hinges lock, strike plate, hold fasts, Peg etc complete all as specified and as directed by Engineer-in-Charge. |
| 57 | S&F flush shutters, 35 mm thick, solid core construction with particle board core and plywood face panels commercial type on both sides with lipping/ frame to match complete all as specified and as directed by Engineer-in-Charge. |
| 58 | S&F solid PVC door frame of size 50 x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, fixing in openings as per specifications complete all as specified and as directed by Engineer-in-Charge. |
| 59 | S&F factory made particle board core solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed. |
| 60 | M&L for 18/ 19 mm thick MDF board, commercial type, fixed with screws to timber framework as in linings, panelling, cupboard shutter, shelf, kitchen cabinets etc. complete all as specified and as directed by Engineer-in-Charge. |
| 61 | S&F Solid PVC Wall Lining consisting of 5 mm thickcoloured PVC sheet inclusive of solvent cement and preparing existing surface and fixing at site as on cupboard etc complete all as specified and as directed by Engineer-in-Charge. |
| 62 | S&F 18 mm thick coloured solid PVC Board suitably fixed as in shelving of cupboard etc as per direction and specifications complete all as specified and as directed by Engineer-in-Charge. |
| 63 | M&L for preparation of wooden surfaces of any description over 10 cm width or girth and applying two coats of synhetic enamel paint over a coat ofpink primer complete all as specified and as directed by Engineer-in-Charge. |
| 64 | S&F 100 mm sizebutt hinges \"medium weight\" stainless steel complete all as specified and as directed by Engineer-in-Charge. |
| 65 | S&F 100 mm long stainless steel barrel tower bolts complete all as specified and as directed by Engineer-in-Charge. |
| 66 | S&F 150 mm stainless steel handles complete all as specified and as directed by Engineer-in-Charge. |
| 67 | S&F 250 mm long stainless steel sliding door bolt with hasp, staple (bolt type) and fixing clips complete all as specified and as directed by Engineer-in-Charge. |
| 68 | S&F framed work such as grills, grating, etc., with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work for water tanks and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed by Engineer-in-Charge. |
| 69 | S&F anodized aluminium frame with Powder Coating (minimum thickness of powder coating 50 micron) for doors, windows, ventilators, partitions etc. with one or more rebates including joining cleat for fixing etc complete all as specified and as directed by Engineer-in-Charge. |
| 70 | S&F Anodised aluminium door shutters with Powder Coating (minimum thickness of powder coating 50 micron), aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed by Engineer-in-Charge. |
| 71 | S&F anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.) hinges type B-21 100mm long (2 No.) suitable handle (1 No.) complete all as specified and directed. |
| 72 | S&F anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design /pattern, with approved standard section and fixed to the existing window frame with C.P. brass /stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. |
| 73 | S&F 4.8 mm thick Sheet glass, tinted, of size exceeding 0.5 sqm in each pane, ordinary quality and glazing with and including aluminium beading and rubber gasket for aluminium Doors and windows complete all as specified and as directed by Engineer-in-Charge. |
| 74 | M&L for 4 mm thick Aluminium Composit panel (ACP) of approved colour as in doors, windows & partitions fixing with aluminium beading or as manufacturers instructions including joint filling and tapping, with necessary arrangement complete all as specified and as directed by Engineer-in-Charge. |
| 75 | S&F 3.0 mm thick sheet glass, figured, pin head type, of size in squares not exceeding 0.50 sqm in each pane incl glazing with oil putty complete all as specified and as directed by Engineer-in-Charge. |
| 76 | S&F stainless steel wire cloth, 0.36 mm nominal dia. of wire and average width of aperture 1.40 mm fixed with tinned tacks or stainless steel wire staples including all cuttings, wastage, etc complete all as specified and as directed by Engineer-in-Charge. |
| 77 | S&F in repairs aluminum (extruded section body) door closer, hydraulically regulated, universal type suitable for door 61 to 80 Kg of approved make including fixing in doors complete all as specified and as directed by Engineer-in-Charge. |
| 78 | S&F floor spring, double action hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box main body with steel cover, governing pivot made of brass, other parts made of MS heavy duty fixed complete all as specified and as directed by Engineer-in-Charge. |
| 79 | Taking up or down steel tubing of 15/20 mm bore & connection including cleaning for or removal from site complete all as specified and as directed by Engineer-in-Charge. |
| 80 | Supplying and laying 20 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings including cutting, threading and fixing as required on walls/ ceiling or laying in floors complete all as specified and as directed by Engineer-in-Charge. |
| 81 | Supplying and laying 25 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings including cutting, threading and fixing as required on walls/ ceiling or laying in floors complete all as specified and as directed by Engineer-in-Charge. |
| 82 | S&F brass elbow suitable for 20 mm CPVC Pipe complete all as directed. |
| 83 | S&F brass elbow suitable for 25 mm CPVC Pipe complete all as directed. |
| 84 | S&F brass Tee suitable for 20 mm CPVC Pipe complete all as directed. |
| 85 | S&F brass Tee suitable for 25 mm CPVC Pipe complete all as directed. |
| 86 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, sills, sunsheds, shelves, lintel etc. and cutting chases for concealed water tubing or concealed conduit wiring etc. complete all as specified and as directed by Engineer-in-Charge. |
| 87 | S&F in repair vitreous china wash down water closet pan (Pedestal Pattern), white, including plastic water closet seat cover, black, closed pattern with flat bottom with mild steel chromium plated or aluminised hinging device and fixing with all joints to WC pan complete all as specified and as directed by Engineer-in-Charge. |
| 88 | S&F in repair PVC 10 litres capacity syphonic action type flushing cistern, low level with inlet, ball valve and floatincluding brackets, flush pipe of PVC 32 mm bore and connection to WC pan complete all as specified and as directed by Engineer-in-Charge. |
| 89 | S&F in repair vitreous china wash hand basin, white, flat back, size 550 x 400 mm including waste fitting brass chromium plated and fixing with new brackets including cutting and pinning in ends of brackets complete all as specified and as directed by Engineer-in-Charge. |
| 90 | S&F in repair Pillar tap 15 mm bore dia, fancy type, cast copper alloy with capstan heads chromium plated screwed down hidh pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and as directed by Engineer-in-Charge. |
| 91 | S&F in repair soap dish, brass chromium plated, fixed to plugs with brass chromium plated screws complete all as specified and as directed by Engineer-in-Charge. |
| 92 | S&F in repair two way Bib taps, 15 mm bore, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed by Engineer-in-Charge. |
| 93 | S&F in repair 15 mm bore bib taps, cast copper alloy fancy type, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by Engineer-in-Charge. |
| 94 | S&F in repair Stop valves/ Angle Valve, 15 mm bore, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unionsand fixed complete all as specified and as directed by Engineer-in-Charge. |
| 95 | Supply and Fixing in repair brass, CP, fancy wall mixer with L bends (including provision of overhead shower & hand shower) for mixing hot & coldwater screwed down for iron pipe 15 mm bore and fixed, with including hand shower and tube complete all as specified and as directed by Engineer-in-Charge. |
| 96 | Supply and Fixing in repair brass chromium plated shower rose, 125 mm size, with swivel joints, fixed to steel pipe or union 15 mm bore, complete all as specified and as directed by Engineer-in-Charge. |
| 97 | S&F PVC (SWR) floor trap 100 mm dia, plain with grating including jointing to waste pipe fixed in solvent cement complete all as specified and as directed by Engineer-in-Charge. |
| 98 | S&F in repair Tolilet paper holder, with flat recessed type stainless steel complete all as specified and as directed by Engineer-in-Charge. |
| 99 | S&F Sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with CP bracket guard & railing 60 cm long complete all as specified and as directed by Engineer-in-Charge. |
| 100 | S&F bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood & fixed to wooden plugs with CP brass screws & cup washers complete all as specified and as directed by Engineer-in-Charge. |
| 101 | S&F Brass chromium plated towel rail, D type, 600 mm long between flanges complete all as specified and as directed by Engineer-in-Charge. |
| 102 | S&F in repair curtain rod 20 mm dia, mild steel chromium plated with fixing brackets, stop rollers etc. complete all as specified and as directed by Engineer-in-Charge. |
| 103 | Cutting into existing manholes for connecting new drains 100 mm dia, making good to pipe & rendering, cutting out existing benching for & forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4, type B-1 smooth finished & reforming benching as required complete all as specified and as directed by Engineer-in-Charge. |
| 104 | Supply and fixing in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position, complete all as specified and directed by Engineer-in-charge. |
| 105 | Supply and fixing in repair toilet paper holder, cast copper alloy, chromium plated fixed in position, complete all as specified and as directed by Engineer-in-Charge. |
| 106 | S&F in repair PVC flexible waste pipe of standard length, 25 mm dia with PVC cap suitable for waste coupling 32/ 40 mm complete all as specified and as directed by Engineer-in-Charge. |
| 107 | S&F in repairs 1000 litres capacity rotational moulded polythylene water storage tanks, tripple layered (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including tank nipple- 04 Nos and 20 mm bore dia brass Ball valves, high pressure with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc complete all as specified and as directed by Engineer-in-Charge. |
| 108 | S&F in repair sinks made of stainless steel l mm thick for kitchen or laboratory use with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 510 mm x 510 mm with bowl size 460mm x 460 x 230mm complete all as specified and as directed by Engineer-in-Charge. |
| 109 | S&F in repair vitreous china bowl urinal, half stall type, white with grating and union for discharge pipe, PVC connection fixed complete to walls complete all as specified and as directed by Engineer-in-Charge. |
| 110 | S&F vitreous china urinal partition white of size 310 x 700 mm, urinal partitions slabs terminating about 40 cm above floor line complete all as specified and as directed by Engineer-in-Charge. |
| 111 | M&L for Shotcreting 25mm thick as in RCC columns, beams and slabs etc in layers with approved M-25 design mix concrete having the specified minimum characteristic compressive strength (with ordinary Portland cement, coarse sand and grade stone aggregate of 10mm maximum size in proportion as per design criteria with wet mix process) including the cost of centring and shuttering at edges and corners etc as directed by Engineer-in-Charge including chipping of unsound / weak concrete material 25mm average thickness from slabs, beams, columns etc with manual chisel and /or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes and thoroughly washing with water and allowing it to dry etc incl Dr Fixit epoxy zinc primer @ 6sqm/ litre at DFT of 100 microns as per specifications and disposal of debris for all lead and lifts all complete all as specified and directed by Engineer-in Charge. |
| 112 | M&L for shotcreting 50mm thick as in RCC columns, beams and slabs etc in laying with approved M-25 design mix concrete having the specified minimum characteristic compressive strength (with ordinary Portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria with wet mix process) including the cost of centring and shuttering at edges and corners etc as directed by Engineer-in-charge including chipping of unsound / weak concrete material 50mm average thickness from slabs, beams, columns etc with manual chisel and /or by standard power driven percussion type or of approved make including tapering of all edges, making concrete surface and reinforcement with wire brushes and thoroughly washing with water and allowing it to dry etc incl Dr Fixit epoxy zinc primer @ 6sqm/litre at DFT of 100 microns as per specification and disposal of debris for all lead and lifts all complete all as specified and directed by Engineer-in-Charge. |
| 113 | Providing and fixing hard drawn 4mm thick wire fabric of size 75x25mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of “L” shaped mild steel shear key welder with existing reinforcement including the cost of materials, labour, tool & plants as approved by Engineer-in Charge. |
| 114 | Taking down carefully old and unserviceablecopper/ aluminium point wiring for light/ fan/ socket or power point complete including fittings such as switches, ceiling rose, pendents, regulators, sockets, bell, distribution boards andMCB\"s etc and making good disturbed surface of walls, floors etc to match with the existing surface complete all as specified and as directed by Engineer-in-Charge. |
| 115 | Point wiring complete with 1.5 sq.mm PVC insulated unsheathed multi-stranded FRLSH copper conductor 1100 Volts grade, ISI marked, drawn through in and including suitable dia of rigid PVC conduit medium grade and conduit accessories, concealed in stone / brick masonry walls, roofs, floors etc, by means of saddles and clips etc, including provision of modular metal flush boxes with modular frame plate and white cover of required modules for housing switches, sockets, regulators etc., including 1.5sq.mm PVC insulated unsheathed multi-stranded FRLSH copper conductor cable as earth continuity conductor for following points and connecting to common earth dolly, complete all as specified and directed. |
| 116 | NOTE for serial item no 114.00: (i) The quoted rate shall deemed to include the cost of metal flush boxes, modular white cover plate, provision of blank plates as per site requirement etc.(ii)Quoted rate shall also deemed to include cost of making necessary chases in walls for inserting metal boxes and making good the disturbed surfaces to match with existing.(iii) Instruction for point wiring to be followed/compiled strictly as per Para 1 (a) to (q), Page Ser No 439 of SSR Part-II of 2020. |
| 117 | One light point controlled by modular switch 6 Amp, single pole, one way, one module, 240V, complete all as specified and as directed by Engineer-in-Charge. |
| 118 | One ceiling Fan/ Exhaust Fan/ Wall fans point controlled bymodular switch 6 Amp, single pole, one way, one module, 240V, complete all as specified and as directed by Engineer-in-Charge. |
| 119 | One5 Amp socket outlet point on independent board controlled bymodular switch 6 Amp, single pole, one way, one module, 240V, complete all as specified and as directed by Engineer-in-Charge. |
| 120 | One5 Amp socket outlet point on same board controlled bymodular switch 6 Amp, single pole, one way, one module, 240V, complete all as specified and as directed by Engineer-in-Charge. |
| 121 | One light point controlled bymodular switch 6 Amp, single pole, two way, two module, 240V, complete all as specified and as directed by Engineer-in-Charge. |
| 122 | All as per Serial Item No. 114.00 here-in-before but for One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sq.mm size complete all as specified and as directed by Engineer-in-Charge. |
| 123 | All as per Srl item No. 114.00 here-in-before but with 2.5 Sqmm single core multi stranded copper conductor of 1100 volts grade PVC FRLSH insulated and sheathed cable for one multipurpose switch socket outlet 6 pin6/16 Amps on independent board including 2.5 Sqmm single core solid copper conductor 1100 volts grade PVC insulated and sheathed cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed by Engineer-in-Charge. |
| 124 | S&F Modular switch 1 way 6A,1 module, one way complete all as specified and as directed by Engineer-in-Charge. |
| 125 | S&F Modular switch 1 way 16A,1 module, one way complete all as specified and as directed by Engineer-in-Charge. |
| 126 | S&F Modular Bell push 6A, 1 module, single pole one way, complete all as specified and as directed by Engineer-in-Charge. |
| 127 | S&F switch modular two way 6A,1 module complete all as specified and as directed by Engineer-in-Charge. |
| 128 | S&F electric call bell/ buzzer, AC, 230 volts, single pole, complete all as specified and as directed by Engineer-in-Charge. |
| 129 | S&F modular socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed by Engineer-in-Charge. |
| 130 | S&F modular socket 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed by Engineer-in-Charge. |
| 131 | S&F modular fan step type regulator, 120W - 2 module complete all as specified and as directed by Engineer-in-Charge. |
| 132 | S&F ceiling rose 65 x 50mm three terminals PVC/ polycorbonate, isolated body complete all as specified and as directed by Engineer-in-Charge. |
| 133 | Supply and fix in repair LED light fitting mirror type with high out put diffuser, 2 feet, 10 Watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge. |
| 134 | Supply and fix in repair LED light fitting 1 x 20 Watt, 220V, AC decorative box type with driver, holder includig LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engineer-in-Charge. |
| 135 | S&F in repair LED Slim Panel CRCA housing, white powder coating with PC diffuser, wattage 36 Watt± 10%, rated luminaire efficacy 100 lm/W, CRI ≥80 Ra,beamangle 120° suitable for armstorng/ grid ceilling, of size 2\"x2\" with its super bright LED life span not lessthan 50000 hrs, including LED strip, recess mounted with driver efficiency ≥85%and others accessories as per manufactures recommendation including fixing arrengement complete all as specified and as directed by Engineer-in-Charge. |
| 136 | S&F in repair surface/ recess mounted (As per site requirement) slim square/roundtype LED panel with die cast aluminium housing and smooth powder coated finish with antiglare UV stabilized diffuser and separate energy efficient eletronic driver having wattage 15 watt LED panel light having dimensions 120x120mm and making connection accessories complete all as specified and as directed by Engineer-in-Charge. |
| 137 | S&F in repair decorative wall mounted lamp with1 light Opal Glass with Chrome Finish (SS) including 1 x 7 watt LED lamp complete all as specified and as directed by Engineer-in-Charge. |
| 138 | S&F in repair span recessed and surfaceLED 1\" x 4\"ft panel ceiling light with high performance, commercial grade solution suitable for hospitals, schools, offices and so much more (> 120lm/W)having white powder coated CRCA housing, antiglare diffuser with separate energy electronicdriver of capacity 40 Watt including fixing arrangement with existing complete all as specified and as directed by Engineer-in-Charge. |
| 139 | S&F in repair downlights orbit LED 15 Watt cylinders employ the same quality lighting and design configuration to ensure consistent colour point between luminaries within a lighting application with colour option in 3000K CCT beam angle 36 degree including fixing arrangement with existing complete all as specified and as directed by Engineer-in-Charge. |
| 140 | Supply and fixing in repair building security light fittings LED 30 W, including suitable dia of GI brackets with necessary clamp, nuts and bolts, etc complete all as specified and as directed by Engineer-in-Charge. |
| 141 | S&F MCB distribution board sheet metal single pole and neutral (SPN) 8 way, double door, with 200 Amp rated bus bar 240 volt, including taking down of exisitng old DBs complete all as specified and as directed by Engineer-in-Charge. |
| 142 | S&F sheet metal enclosure distribution board triple pole and neutral (TPN) 8 way, double door,415 volt, including taking down of exisitng old DBs complete all as specified and as directed by Engineer-in-Charge. |
| 143 | S&F VTPN DB, 8 way, with MCCB as incommer, metal door, ready to use DBs provided with Neutral Bar, Mechanical Impact Strength IK-08, Insulated busbar assembly, cement spill protector, color-coded interconnecting wire set, cable ties blanking plates and circuits identification labels suitable for3 pole and 4 pole MCCB\"s upto 125 Amp as Incommer and MCBs (TP/SP) as outgoing, IP 43 protection, conforming to IS 8623-1 & 3, IEC 61439-1 & 3 including complete including taking down of exisitng old DBs complete all as specified and as directed by Engineer-in-Charge. |
| 144 | Supply and fix MCCB 125 Amp, 415 Volt, 4 Pole, Ics=100% of Icu with spreader & rom,16 KA complete including taking down of exisitng old MCCBs complete all as specified and as directed by Engineer-in-Charge. |
| 145 | S&F RCBO, Three Pole and Neutral (TPN) 63-100 Amps, 415 Volt, electromechanical FP RCBOs used as TPN /FP RCBOs with rupturing capacity not less than 10 KA, and IS 12640-2 & IEC 61009-1 complete all as specified and as directed by Engineer-in-Charge. |
| 146 | S&F MCB Three Pole and Neutral (TPN) 63-100 Amps, 415 Volt, \"C\" Curve with rupturing capacity not less than 10 KA, including taking down of exisitng old MCBs complete all as specified and as directed by Engineer-in-Charge. |
| 147 | S&F MCB Single Pole and Neutral (SPN) 32-63 Amps, 240 Volt, \"C\" Curvewith rupturing capacity not less than 10 KA, including taking down of exisitng old MCBs complete all as specified and as directed by Engineer-in-Charge. |
| 148 | S&F RCBO single Pole and Neutral (SPN) 32-63 Amps, 240 Volt, electromechanical DP RCBOs used as SPN /DP RCBOs with rupturing capacity not less than 10 KA, and IS 12640-2 & IEC 61009-1 complete all as specified and as directed by Engineer-in-Charge. |
| 149 | S&F MCB Single Pole (SP) 06-32 Amps, 240 Volt \"B\" Curve with rupturing capacity not less than 10 KA,including taking down of exisitng old MCBs complete all as specified and as directed by Engineer-in-Charge. |
| 150 | Supply and fixing single pole and neutral enclosures with two pin and earth plug and socket complete with single pole MCB 20 Amps, 240 V,including taking down of exisitng old SPN enclosure complete all as specified and as directed by Engineer-in-Charge. |
| 151 | S&F in replacement of MS down rod for ceiling fans, heavy duty 15mm nominal dia 24\" long duly painted in matching colour complete all as specified and as directed by Engineer-in-Charge. |
| 152 | S&F in replacement of MS down rod for ceiling fans heavy duty 15mm nominal dia 36\" long duly painted in matching colourcomplete all as specified and as directed by Engineer-in-Charge. |
| 153 | Dismantling and taking down ceiling fans of any size for servicing by cleaning dust, filling cavities with filler and painting complete with synthetic enamel paint by spraying and re fixing the same in position, connecting and testing complete all as specified and as directed by Engineer-in-Charge. |
| 154 | Dismantlingand taking down wall fans/ exhaust fans ofany size for servicing by cleaning dust, filling cavities with filler and painting complete with synthetic enamel paint by spraying and re-fixing the same in position, connecting and testing complete all as specified and as directed by Engineer-in-Charge. |
| 155 | Dismantling of existing Split/ window type ACs 1.5/ 2.0 TR capacity for servicing by water cleaning dust, filling cavities with filler complete and re-fixing the same position after completion of civil work, connecting and testing completecarefully, complete all as specified and as directed by Engineer-in-Charge.Note: Rate of minor parts shall deem to be included in overall cost of item rate to smooth functioning of the ACs.Miner parts includes bracket with fixtures, nuts, bolts etc. |
| 156 | Dismantling of existing water heater (Geyser) of 25-35 ltr capacity for servicing by water cleaning dust, filling cavities with filler complete and re-fixing the same position after completion of civil work, connecting and testing ccomplete all as specified and as directed by Engineer-in-Charge.Note: Rate of minor parts shall deem to be included in overall cost of item rate to smooth functioning of the water heaters.Miner parts includes nuts, bolts, clamp, thermostat, indicator lamp etc. |
| 157 | S&F security light bracket made out of 25mm bore GI light grade 1.00 metre long to required shape as in bracket for building security light fittings fixed with two pair of MS flat iron clamp of size 32mm x 5 mm thickness of required shape with nuts, bolts and washers suitable for fixing in outer wall of building including painting of mild steel flat iron surface with two coats of synthetic enamel paint over a coat of red oxide primer complete including taking down of unserviceable one complete all as specified and directed. |
| 158 | S&F submain wiring with four single core cables PVC FRLSH insulated unsheathed 16.0 Sqmm stranded copper conductor drawn in and including PVC conduit and its accessories with and including PVC FRLSH insulated one run single core cables 16.0 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete including taking down of exisitng old wires of any type/ any size complete all as specified and as directed by Engineer-in-Charge. |
| 159 | S&F submain wiring with four single core cables PVC FRLSH insulated unsheathed 10.0 Sqmm stranded copper conductor drawn in and including PVC conduit and its accessories with and including PVC FRLSH insulated one run single core cables 10.0 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete including taking down of exisitng old wires of any type/ any size complete all as specified and as directed by Engineer-in-Charge. |
| 160 | S&F submain wiring with four single core cables PVC FRLSH insulated unsheathed 6.0 Sqmm stranded copper conductor drawn in and including PVC conduit and its accessories with and including PVC FRLSH insulated one run single core cables 6.0 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete including taking down of exisitng old wires of any type/ any size complete all as specified and as directed by Engineer-in-Charge. |
| 161 | NOTE for serial Item no 151.00 to 153.00:- (i) Four runs of copper conductor wire, one runs of copper earth continuity conductor and PVC conduitshall be measured as one unit length.(ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.(iii) Instruction for submain wiring to be followed/compiled strictly as per Para 1 & 2, Page Ser No 461 of SSR Part-II of 2020. |
| 162 | S&F submain wiring with Two single core cables PVC FRLSH insulated unsheathed 4.0 Sqmm stranded copper conductor drawn in and including PVC conduit and its accessories with and including PVC FRLSH insulated one run single core cables 4.0 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete including taking down of exisitng old wires of any type/ any size complete all as specified and as directed by Engineer-in-Charge. |
| 163 | NOTE for serial Item no 154.00- (i) Two runs of copper conductor wire, one runs of copper earth continuity conductor and PVC conduitshall be measured as one unit length.(ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.(iii) Instruction for submain wiring to be followed/compiled strictly as per Para 1 & 2, Page Ser No 461 of SSR Part-II of 2020. |
| 164 | M&L for earthing complete with GI earth plate electrode 600mm x 600mm x 6.0 mmthickburied directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip of size 25 mm x 4 mm by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 40mm dia GI pipe \"medium grade\", watering pipe 20mm dia GI pipe \"light grade\", GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 50mm thick RCC cover (1:2:4) type B1 mix with 8mm dia nominal reinforcement @ 100mm c/c both ways etc complete all as shown in electrical plate No. 3 connected to earthing test point, including testing on completion, including taking down of old earthing any type complete all as specified and as directed by Engineer-in-Charge. |
| 165 | M&L for earthing complete with GI earth plate electrode 600mm x 600mm x 6.0 mmthickburied directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth wire of size 4 mm by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 40mm dia GI pipe \"medium grade\", watering pipe 20mm dia GI pipe \"light grade\", GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 50mm thick RCC cover (1:2:4) type B1 mix with 8mm dia nominal reinforcement @ 100mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, including taking down of old earthing any type complete all as specified and as directed by Engineer-in-Charge. |
| 166 | NOTE for serial item no 155.00 & 156.00:- (a) Rate quoted shall deemed to include cost of testing, excavation in any type of strata, RFR and removal upto 50 metre, PCC pit, funnel and RCC cover plate.(b) Rate quoted shall deemed to include GI earth strip/ wire and GI protection pipe light grade of upto 7.5 meter length.(c) Rate quoted shall deemed to include taking down old Earthing.(d) Minimum 100 Kg salt and 100 Kg charcoal granual type to be used for each earth pit. The bed to be done in 3 x 15 cm depth of salt and 3 x 15 cm depth of charcoal in aternate layer.(e) PVC type DC insulators with screws, nuts, bolts etc to be used in suface/ wall/ floor for mounting of wire and distance between two insulator shall not be less than 1.0 mtr. |
| 167 | M&L for galvanised iron strip 25 x 4 mm buried in ground with saddles and fixing screwes etc for roof conductors and down conductors including removing and replacement of deterioted SS bolts, nuts and washers as required at site etc in the existing GI strip of any size from the starting point to upto the end connected points all as specified and directed by Engr-in-Charge. Note 1. PVC type DC insulators with screws, nuts, bolts etc to be used in suface/wall/floor for mounting of strip and distance between two insulator shall not be less than 1.0 mtr.Rate quoted shall deemed to be included the PVC DC insulators. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy