Tender For Special Repair To Bldg No Tr-70,Tr-71,Tr-72 (Or Single Living Lines) Of Engr Regt At Oaf, Srinagar Under Ge 970 Ews.; 1 Taking down chowkats or frames with shutter (without taking off shutter from the frames) n. exc 1.50 Sqm each complete all as specified and directed. 2 Taking down chowkats or frames with shutter (without taking off shutter from the frames) exc. 1.50 Sqm n.exc 4 Sqm each complete all as specified and directed. 3 Material & labour Pressed steel frames (Factory made) made out of 1.25 mm thick black MS sheet for doors, with one or more rebates including necessary s&f lugs, Butthinges, lock strike plate, etc complete, size of frame 125x60mm incl bottom of each chowkat to be welded with 2 nos 25x25x3mm thick flat iron projecting 10 cm on either sidecomplete all as specified and directed. 4 M & L PCC 1:2:4type B0 12 .5 mm graded aggregatecement concrete as filling to pressed steel frames complete all as specified and directed. 5 S&F factory made Box Type mild steel windows side hung glazed shutters with chowkets with glazing bars to receive glass and other side of the window wire mesh shutters to receive wiremesh orwire guage dovetailed or welded and steel peg stay with and including necessary welding, reveting, tower bolt, hanlde, holdfast & hinges as per Drg No.CESZ/TD-1018/2011 Sheet No 1/3 complete all as specified and directed. (Note : Guard barsshall be mensurementand paid separately). 6 M&L PCC 1:2:4 type B0 12.5mm graded aggregatte as in hold fasts and bed blocks etc including necessary form work complete all as specified and directed. 7 Dismantling wrought iron or mild steel work (used in framework for stageing of water tank) of any description not otherwise providedcomplete all as specified and directed. 8 M&L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed. 9 S&F 35 mm thick, factory made 2nd class hardwood glazed and skeleton shutters, open rebated and prepare to receive gauge etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for secruing glass/gauge etc size of member of shutter as specified in SSR Part-I Section 8 Clause 8.20(a), fitted to chowkats complete all as directed. 10 S&F 35mm factory made shutters plain framed, panelled shutterwith lock rail and panel of 9 mm BWP commercial ply or 12 mm to 15mm veneered particle board with commercial veneering on both faces.The size of rail and stile as per IS-1003 (Part - I) kiln seasoned and chemically pressure treated complete all as specified and directed. 11 S & F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. 12 S&F sheet glass 4.00 mm thick ordinary quality and glazing with oil putty in square, rectangle n.exc 0.5 Sqm in each pan complete all as specified and directed. 13 S&F Floor door stopper of aluminum alloy body and tongue anodized with hard drawn steel spring fixed in floor of length 150mm complete all as specified and directed. 14 S&F mild steel 300mm, ordinary rat rail rod pattern springs, including roller and roller plate complete all as specified and directed. 15 S&F 200mm size aluminium anodised, barrel tower bolt of extruded section complete all as specified and directed. 16 S&F 250 mm long aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixingclips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified directed. 17 S&F Extruded aluminium alloy handles 150 mm long fabricated type anodised complete all as specified and directed . 18 S&F in repair Curtain rod or Harrison rails, mild steel chromium plated with fixing brackets, stops, rollers etc. complete all as specified and as directed. 19 Dismantiling timber scantling 40 sqcm and over insection in any position for framed work all as specified and directed. 20 S&F for 2nd class hardwood (wrought) in scantling for timber frame and fixed complete all as specified and directed. 21 Refixing of timber scantling obtained from dismantling complete all as specified and directed. 22 M&L preparation of new / old or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. 23 M&L two coats of synthetic enamel paint over a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm in width and girth complete all as specified and directed. 24 M&L for Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with Creosoting complete all as specified and directed. 25 Demolition of unreinforced cement concrete in ground floors and paving n. exc 15cm thickness (below or above ground level) complete all as specified and directed. 26 Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed. 27 M&L for 75mm thick (1:3:6) Type-C-2 (using 40mm graded crushed stone aggregate) as in plinth protection or paving, finishing cement concrerte surface even and smooth without using extra cement complete all as specified and directed. 28 M&L for 25mm thick (1:2:4) Type-B-1 (using 12.5mm graded crushed stone aggregate) as in sub base of flooring complete all as specified and directed. 29 Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. 30 M&L non skid coloured designer ceramic tiles7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15mm thick screed bed in CM (1:6)complete all as specified and directed. 31 -ditto- all as per item No.30 above but on skirting over with and including 10mm thick backing coat in CM 1:4 complete all as specified and directed. 32 M&L rendering 15 mm thick in CM 1:6 on brick/concrete/stone wall surfaces of any description, and finishing the surfaces even and smooth without using extra cement complete withand including taking down cement or lime plaster of any description from stone /brick/concrete wall etc incl raking out joints hacking for key scrurbbing down with water and disposing of the rubbish complete all as specified and directed. 33 M&L rendering 15 mm thick in CM 1:4 with and including mixing of liquid WPC of approved make @ 200ml per bag of cement on brick/concrete/stone wall surfaces of any description, and finishing the surfaces even and fair complete withand including taking down cement or lime plaster or racking of pointing and scrubbing out existing finishes on wall of any for three storey bldg incl all necessary arrangement like scaffolding and masonry complete all as specified and directed. 34 M&L brick work with sub class B bricks straight or curved in plan exc 6 mtr mean radius built in CM (1:6) using old size bricks with and including demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. 35 M&L brick work with sub class B bricks straight or curved on plan to any radius in half brick thick wall built in CM 1:4 with and including demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. 36 M&L rendering 15 mm thick in CM 1:6 on brick/concrete/stone wall surfaces of any description, and finishing the surfaces even and smooth without using extra cement complete all as specified and directed. 37 M&L rendering 15 mm thick in CM 1:4 with and including mixing of liquid WPC of approved make @ 200ml per bag of cement on brick/concrete/stone wall surfaces of any description, and finishing the surfaces even and fair complete complete all as specified and directed. 38 M&L for preparing new/old plastered or unplastered surfaces on walls & other surface and applying two coats of oil emulsion distemper over a coat of 3 mm wall care putty with rubbing or smoothing of surface upto ture finish over a coat of water base primer complete all as specified and directed. 39 M&L preparing new/old plastered surface of walls and applying two coats of cement based paint over a coat of cement base primer complete all as specified and directed complete all as specified and directed by Engr -in-Charge.. 40 S&F 12mm thick Gypsum board for ceiling fixed with GI Powder coated snap grid 605 x 605mm frame work as in false ceiling including hangers 4mm dia GI wire (upto 1200mm centre to centre upto length as required at site) and adjusting level fixed to roof wooden member by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners complete with and including dismantling ceiling baords of any description of any thickness incl cover fillets complete all as specified and directed. 41 M&L for factory made 60mm thick non skid pre-polished coloured interlocking paver block made with grey Cement and pigment not less than compresive strength 35 Kg/Cm (M-35) sqm laid over and including 25mm thick dry sand coushoining complete all as specified and directed. 42 S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550mpa as in roof covering /cladding to wall, fixed with self tapping screws complete with and including dismantling corrugated steel sheeting, any gauge, thickness, including nainital or similar roof coverings complete all as specified and directed.completed all as specified and directed by Engr-in-Charge. 43 S&F for pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550mpa as in roof covering /cladding to wall, fixed with self tapping screws as in ridge,eaves boards, hips, velly gutter drip and straight flushing of reuired machine moulded shape and size complete with and including dismantling plain steel sheeting, any gauge, thickness, including nainital or similar roof coverings and eaves boards of any description complete all as specified and directed.complete all as specified and directed. 44 Taking down carefully copper/aluminium point wiring from woodenbattan/ conduits or from the wall by chasing/cutting (light, fan, socket or power) completely including (fittings such as switches, ceiling roses, pendants, regulator, sockets etc. to be measured separately) and making good disturbed surfaces of walls, floor etc.complete all as specified and directed. 45 Taking down old MCCB,TPN DBs , SPN DBs,SP MCB & Main Switch/enclosure box of any make and type from the site and making good surface complete all as specified and directed. 46 Taking down old submain wiring of any size and make from the site and making good surface complete all as specified and directed. 47 M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through new PVCconduit20 mm dia medium grade ISI marked and all conduit accessories concealed in walls/ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded modular metal flush box duly make embossed, concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc, complete all as specified and as directed for the followings:- 48 (a)One light/fan point controlled by one by one way switch ( switch to be measured and paid separtely) 49 (b)One 5 pin socket outlet 5 hole 5 Amp independent including PVC unsheathed copper conductor 1.5 Sqmm cable asearth wire connected to common earth and to earth dully socket & switches to be measured and paid separately. 50 (c)-ditto- as above item No 49but Same board complete all as specified and directed. 51 One power point with insulated stranded copper conductor cable 4 Sqmm single core and PVCinsulated FRLS 1100 Volts unsheathed copper conductor 4 Sqmm stranded conductor as earth wire connected to dolly complete (socket and switches to be measured and paid separately)Note for Item 5 & 6 : (i) In case the wiring is encountered with any beam/column, then the wiring will run on PVC casing/caping to avoid any damage to the RCC portion.(ii) No cutting shall be done in the roof for laying PVC conduit for ceiling fan point wiring, in this specified portion wires shall run through the surface new conduit shall be provided as mentioned in note (i) above.(iii) Proper colour code will be used for wiring as per the electrical rule and as directed by EIC. 52 M & L Submain wiring with two run single core 6 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100volts grade in and including PVC conduit ISI marked alongwith one run of 6 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main DB and testing on completion etc complete all as directed. 53 S&F in Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls complete all as specified and directed. 54 M&L in replacementswitch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed. 55 M&L in replacement switch Modular type 16 Amps 1Way, 1 module with modular plate light marking 230V AC complete all as specified and directed. 56 M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed. 57 M&L in replacement Modular socket outlet 2/3 pin 6/16Amp universal socket 2 modulecomplete all as specified and directed. 58 M&L ceiling rose 3 phase PVCpolycorbonate,isolated body complete all as specified and directed. 59 Supply and fix LED batten luminaire surface mounted T-8, 4 feet system wattage of not less than 20 Watts with lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1,Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 100 Lumens/watt andincluding connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed completeallas specified and directed. 60 Supply and fix LED batten luminaire surface mounted 2 feet system wattage of not less than 10 watts and not less than 1000 lm with life time of 25000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, Class - 1, SDCM <5 short circuit and over circuit protection, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥80 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. 61 S&F 70 W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover.System level efficacy of the Luminarie should more than 80lm/W. The color temperature is around 6500 K with a color rendering index of 70.The luminaire is IP:66 protected.It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of sutable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed. 62 S&F factory made epoxy powder coated Distribution board (MCCB DB) TPN 4 way vertical type, IP - 43 Protection made out of min 1.6 mm thick CRCA sheet, fabricated, metal double door fixed to wall and suitable for universal mounting and including 200 Amps rated copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removeable gland plated with knockouts and suitable for TPN MCCB 125/160 Amps as incomer and 12 SP or 04 Nos TP MCBS as outgoing complete all as specified. 63 M&L for earthing complete with galvanized steel earth plate 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized iron strip 25x4 mm size as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel besides welding at all joints including excavation and earth work, GI pipe light grade 15mm bore for protection of G.I. strip from earth electrode to the earth test point of galvanized Iron/steel of size 75 x 75 x 25 mm, supplying and laying charcoal dust, common salt, PCC 1:2:4 typeB-1 using 20mm graded stone aggregate chamber and MS angle iron frame 40 x 40 x 3 mm and RCC cover 40 mm thick RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, round, PGI funnel and wire mesh, 20 mm dia GI pipe Med grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified & directed. 64 S&F MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCBSPN as incomer and SP MCBs as out going with 200 Amp rated bus bar,neutral link earth link complete 65 S&F sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 220 volts, 50 Hz, 10KA breaking capacity complete all as specified and directed. 66 Taking down carefully the existing ceiling fan of 1200mm from its position after disconnecting electric connectionand checking its for its serviceability and deposite to MES store complete all as specified and directed. 67 Hanging only ceiling fan any size (M.D.supply) and connecting up including provision of cable from ceiling rose or connector to fan. 68 Taking down carefully the existing Geyser of 25/50 ltr from its position after disconnecting electric connectionand checking its for its serviceability and re-fixing with connection pipe hot/cold complete all as specified and directed. 69 Supply and fix MCCB 160 Amps, FP 415 volts 36 50 HZ with thermal magnetic setting complete all as specified and directed. 70 Supply and fixMCB DP 32 Amps240 volts 10 KA 50 HZB curve complete all as specified and directed by Engineer in charge 71 Supply and fixMCB SP 5-32 Amps 240 volts 10 KA 50 HZ B curve complete all as specified and directed. 72 Taking down old unservicable cable of any size or typefrom any description (trenches, walls, ceilings., etc) from various locations, including any short length,all as specified & directed. 73 Supply and Layingjointing & testing XLPE insulated PVC sheathed armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade, cross sectional area 35 Sqmm 3.5 core complete fixed to floor/walls/ceiling with suitable size of clamp/saddles complete all as specified and directed. 74 Excavation in trenches in soft/loose soil n. exc 1.5 Mtr wide and not exc. 1.5 M deep and getting out including forming bottom surface for laying of pipes complete all as specified and directed. 75 Returning filling in including spreading, leveling, watering and well ramming in layers not exc 25 mm thick complete all as specified and directed. 76 Removal of excavated material to a distance not exc 50 Meter and depositing wheredirected at a level not exc 1.5 M above the starting point complete all as specified and directed. 77 Supplying, laying and cushioning for cable protection in trenches 8 cm deep before laying cable and 15 cm deep over the cable including well punning complete all as specified and dierected 78 Supplying, laying sub class B bricks old size with axis of the bricks perpendicularto the axis of the cable as in cable protection complete all as specified and directed. 79 Supply & Fixingin replacement GI tubing light grade in trenches/fixed to wall/ceiling including required GI fitting of size 40mm dia complete all as specified and directed 80 Taking out/taking down old unserviceable damaged GI/PPR pipe of size 25 to 32mm from trenches/Wall/roof including removing of fittings complete all as specified and directed. 81 Supply & Fix 3-layer PP-R P o l y p r o p y l e n e random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply of external dia 25 mm including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings, band, elbow, union,nipplesand short piecesfixed complete to walls, ceilings or in floors etc complete all as specified and directed. 82 M&L Lagging on pipes of internal dia upto 25 mm, used in external water supply or plumbing all round with, 40mm thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842, provided with chicken mesh wire netting 25 gauze 20mm mesh and finally covering with plaster of pairs , complete, all as specified and directed. 83 Making connection of PPR distribution branch with PPR main ofsizes 16 mm to 40 mm by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed. 84 Supply & Fix PP-R Gate valves (brass insert) ISI markedof external dia 25 mm as per requirement of the site and as complete all as specified and directed.