| 1 | Surface dressing n exc 15 cm deep in soft/loose soil, complete all as specified and directed. |
| 2 | Excavation in trenches for n.exc 1.50m wide not exceeding 10 Sqm on plan and n.exc 1.5m in depth in soft/ loose soil and getting out, complete all as specified and directed. |
| 3 | Excavating over areas hard & dense soil, n. exc 1.5 m deep and getting out, complete all as specified and directed. |
| 4 | M&L for PCC 1:4:8 type D2 graded stone aggregate cement concrete in flooring, foundation, filling and mass, complete all as specified and directed. |
| 5 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed. |
| 6 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m. complete all as specified and directed. |
| 7 | M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed. |
| 8 | M& L for RCC Type B1, (1:2:4) nominal mix (20mm grade aggregate) Foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc., basement slabs, complete all as specified and directed. |
| 9 | M&L for RCC (20mm grade aggregate type B1 (1:2:4) nominal mix Columns, pillars, piers, posts and struts, complete all as specified and directed. |
| 10 | M&L for RCC Type B1, (1:2:4) nominal mix (20mm grade aggregateslabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed. |
| 11 | M&L for RCC Type B1, (1:2:4) nominal mix (20mm grade aggregate) Beams, cantilevers, bressummers, lintels over 1.5m span all as specified and directed. |
| 12 | M&L for RCC Type B1, (1:2:4) nominal mix (20mm grade aggregateto chajjas, complete all as specified and directed. |
| 13 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter, complete all as specified and directed. |
| 14 | M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions, complete all as specified and directed. |
| 15 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), complete all as specified and directed. |
| 16 | M&L for Formwork to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed. |
| 17 | M&L for Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide, complete all as specified and directed. |
| 18 | S&F for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, includingcranking, bending spirally for hooping for columns, hooking ends and bindingwith and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 19 | S&F for mild steel TMT or twisted bars 6 to 8 mm dia as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia as in stirrups etc. complete all as specified and directed. |
| 20 | M& L for PCC 75mm thick type C-1 ,1:3:6 using 20mm graded stone aggregate as in plinth protection, complete all as specified and directed. |
| 21 | M&L for brick work with sub class \"B\" bricks, straight or curved on plan exc. 6 m mean radius, built in CM (1:6), complete all as specified and directed. |
| 22 | M&L for rendering 5mm thick in CM 1:3 finish even and smooth without using extra cement in ceiling, complete allspecified and directed. |
| 23 | M&L for PCC padding 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) of uniform thickness 25 mm average top surface of pain cement concrete padding shall be furnished even and smooth without using extra cement, complete all as specified and directed. |
| 24 | M&L for 15 mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 25 | M & L for applying Bituminious primer on roof surface conforming to IS-3384 bof 1986 @ 0.70 Kg/sqm and applying APP based polymeric membrane minimum weighing 3 Kg/sqm and minimum 3 mm thick reinforced with non-woven polyster matt laid on primed surface by torch application complete all as specified with overlap of 100 mm overlap to be thermo fushed by flame, complete all as specified and directed. |
| 26 | M&L for applying one coat of aluminium paint at the rate of 100 gms/sqm as per manufacturers instructions over bituminous layer,complete all as specified and directed. |
| 27 | M & L for Granite18- 20 mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of graniteflooringincluding 15 mm thick screed bedding in cement mortar 1: 6 and all other similar works,complete all as specified and directed. |
| 28 | M&L for rendering 15mm thick on faces of brick work or concrete surfaces finished even and smooth without using extra cement in CM 1:4, all as specified and directed. |
| 29 | M&L Liquid water proofing compound, complete all as specified and directed. |
| 30 | M&L for 15mm thick rendering in CM 1:6 on fair faces of brick work, surfaces finished even and fair without using extra cement, complete all as specified and directed |
| 31 | M&L for preparation of new plastered ceiling surface and applying three coat of white wash of ceiling, all as specified and directed. |
| 32 | M&L for preparation of new plastered surfaces of wall and applying two coats distemper over a coat of primer birla white wall care putty on wall to obtain smooth finish. completeall as specified and directed. |
| 33 | Preparation of new plastered surface of wall and applying two coats of cement base paint over a coat of primer including balance area complete removal, all as specified and directed. |
| 34 | M&L for Non skid ceramic jointless coloured tiles 7 to 8mm thick (square/ rectangular) area of each tiles exceeding 0.11 sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed with white as coloured cement to match over and including 15mm thick screed bed in cement mortor (1:6), complete all as specified and directed. |
| 35 | M&L for 25mm thick cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as in leveling course etc., complete all as specified and directed. |
| 36 | M&L for glazed ceramic tiles in vertical surfaces of size 450x350x7mm thick set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including rendering 10 mm thick in cement mortor (1:4) on vertical surface as in backing coat, all as specified and directed. |
| 37 | Material and labour in reapair for rubber bead/seal 40mm wide and 3-4mm thick to cover doors/window gap fixed with nails and make good to doors as in repair, complete all as specified and directed. |
| 38 | S & F of framed work such as grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes , framed guard bars, barred iron doors, ladders,windows, balcony in ground floor, framed balusters, walk ways, railings, framework of watertanks and similar work conforming to FE 290 Gde -E-165, complete all as specified and directed. |
| 39 | M&L for preparation of new steel surfaces of any description not otherwise described over 10cm in widht or girth and applying two coat of synthetic enamel paintover a coat of red oxide primer,complete all as specified and directed. |
| 40 | S&F for powder coated anodised aluminium frame/shutters for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified and directed. |
| 41 | S&F in repair for powder coated aluminium anodised three track sliding window weighing not less than 1.35 Kg/RM including 5mm thick glass fixed with rubber gasket. The aluminium member of shutter is 65x40mm alongwith aluminium handle & tower bolt etc., complete in all as specified and directed. |
| 42 | M&L for Anodised aluminium powder coateddoor shutters with frame, aluminium section weighing 1.5 kg/m ( minimum) including 5.5 mm thick glass/ 12 mm thick laminated particle board as per user requirement and all necessary fittings,4 lever locks and two nos tower Bolts size 150mm, two nos handles size 150mm incl joining cleats, glazing clips, rubber packing, anodised alumnium snap beading, screws and lock etc., complete all as specified and directed. |
| 43 | S&F for 2nd class hardwood plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints, complete all as specified and directed. |
| 44 | S&F for 30 mm Flush shutters, solid construction, with block board core and playwood face panels, commercial type on both side, complete all as specified and directed. |
| 45 | S&F for cast brass handles, each 150mm long, complete all as specified and directed. |
| 46 | S&F for cast brass handles, each 100mm long, complete all as specified and directed. |
| 47 | S & F for cast brass butt hinges medium weight cold rolled 100 mm long, complete all as specified and directed. |
| 48 | S & F for cast brass butt hinges medium weight cold rolled 75 mm long, complete all as specified and directed. |
| 49 | S&F in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplesetc., complete all as specified and directed. |
| 50 | Demolition of PCC in ground floor & pavings n.exc 15 cm thickness below or above GL, complete all as specified and directed. |
| 51 | M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified as directed. |
| 52 | M&L forPCC 1:4:8 type D-2 (40mm graded aggregate) Cement concrete in foundations filling and mass concrete etc., complete all as specified as directed. |
| 53 | M&L for Chequered cement concrete tiles 20cmx20cmx25mm thick set and jointed in neat cement slurry including 15 mm thick screed in CM(1:6) and pointed in white or colour cement to match with grey cement and no pigment, complete all as specified and directed. |
| 54 | M & L formachineprecast concrete Hydraulic pressed rubber mouldedinterlocking coloured paver block glossy finish any shape and size confirming to IS 15658 - 2006 of 80 mm thickness, M- 40 grade with grey cement and pigment including 40 mm thick sand cushioning layer, complete all as specified and directed. |
| 55 | M&L for PCC 1:2:4 Type B, using 20mm graded aggregate as in kerb stone in sides of inerlocking tiles including slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 56 | Demolition of cement concrete (Un reinforced)in ground floor & pavings n.exc 15 cm thickness (below or above GL) and removing debries out side MOD land, complete all as specified and directed. |
| 57 | M&L for Pre- painted galvatume aluminum zinc coating GI basedcorrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all specifiedas directed. |
| 58 | M&L for Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all specifiedas directed. |
| 59 | S&F for Rolled mild steel sections conforming to Gde Fe-290 (Gde-165-E) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails & guides for sliding doors, fixed with angle cleats or other, connecting plates complete all as specified. |
| 60 | M&L for 15mm thick rendering in CM 1:4 on fair faces of brick work, with mixing WPC @ 3% by wt of cement surfaces finished even and fair without using extra cement, complete all as specified and directed. |
| 61 | M&L for preparation of new plaster surfaces of walls and applying two coats of oil bound distemper over one coat of primer including 1 mm thick wall care putty car, complete all as specified and directed by Engg-in-Charge. |
| 62 | Material and Labour for preparing newly & Old plastered surfaces of walls / ceilings by scrapping / rubbing and applying two coats of weather proof acrylic exterior paint (100% Acrylic)Base coat of Apex ultima protek duralife and top coat of Apex Ultima protek, Make : Asian Paints) over a coat of alkali resistent primer through authorized applicator onlyincluding use of scaffoldings from Ground floorupto 04 storeys height of bldgs bldgs complete all as specified and directed.Make: \"Apex Ulitima\" of Asian Paints \"trucare\" Primer / \"Weather coat all Guard\"of Berger Paints/Dulux weather shield Max of Dulux Paints/Excel top Guard of Nerolac paints as approved by GE complete all as specifeid. |
| 63 | S&F forpower coated anodised aluminium doors (sliding/ hanging type) with frame size 101.60 x 44.45 x 2.00 mm thick and shutter aluminium anodised and top rail 47.62 x 44.45 x 1.50 mm style 47.5 x 44.5x1.5mm, lock rail 83.50 x 44.45 x 1.50 mm and bottom rail 150.00 x 44.50 x 2.50 mm including necessary aluminium fittings like aluminium butt hinges 04 Nos, aluminium handle 150mm 02 Nos, aluminium tower bolts 200 mm 01 No, aluminium door stopper 01 Nos, jointing cleats glazing cleats, rubber packing, anodised aluminium shape beading screws etc with panelling in two parts with 5mm thick tinted glass in panels including all fittings & fixture, complete all as specified and directed. |
| 64 | S & F powder coated aluminium sections for doors, windows, ventilators, door partition including fabrication of frame shutters and fixing with necessary lugs, cleats, rollers, handles, locking arrangement etc. including all accessories such as glazings clips, and rubber beadings for fixing glass panes in frame, complete all as specified. Note : (i) Glass paneswill be measured & paid separately . (ii)The quoted rate shall be inclusive of cost of rubber beading however it will be not be weighed and not paid separately.(iii) All other minor details including cost of locking arrangement shall be included in the quoted rate.(iv) Windows all around will be sealed with silicon sealant. |
| 65 | S&F in repair for galvanised M S Wire cloth of 0.56 mm nominal dia of wire and average width of aparture 1.18 mm fixed with tinned tack for galvanized wire staple incl fixed in repair, complete all as specified & directed. |
| 66 | M&L for 5.0 mm thick sheet glass ordinary quality and glazing with oil putty in square exc 0.5 sqm in each pane, complete all as specified & directed. |
| 67 | S & F for aluminium grill of 7.5mm x 5.2mm bars of opening as per design No DG No 103 of M/s Decogrille/ RG-103 of M/s Royal Grill fixed with aluminium channel \"F \" 20mmx15mm fixed in position with screw, complete all as specified and directed. |
| 68 | S&F for Curtain rod side brackets anodised aluminium alloy of approved quality, complete all as specified and directed. |
| 69 | S&F in repair 25 mm dia decorative type chromium plated anodised aluminiumalloy with fixing brackts and all other connected works, complete all as specified and directed. |
| 70 | M&L for double chargedVitrified Ceramiccolouredtilesof size of tiles exc0.42 Sqm But Not Exc .1.0 Sqm in each tiles(square/ rectagular) polished,in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade tiles including 15mmthick screed bed layer in CM (1:6), complete all as specified and directed. |
| 71 | Providing & fixing for false ceiling at all heights with semi peforated 12 mm thick micro Regular edged GRG (Glass Fibre Reinforced Gypsum) falseeiling tiles of12mm Size 595 x 595 mm of approved texture,design and patterns having moisturecontent less than 2%, humidity resistance99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS tiles tiles 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of mainT runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length00mm to form grid module of s1ze 600x 600mm , suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1 OOOmm length and Lshape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. complete all as specified and directed. |
| 72 | S & F rolled mild steel Fe 410-W (Gde E-290) quality A in framing of wall cladding (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., complete all as specified and directed. |
| 73 | M&Lfor point wiring using approved colour coding as per IS, with Zero Halogen flame retardant (HFFR), smoke free, non toxic, non corrosive installation cable with UNILAY construction copper conductor 1.5 Sqmm (nominal area), single core, insulated and unsheathed stranded cable 1100 Volts grade ISl-694 marked in & including heavy duty, electric resistance welded (ERW) stove enameled surface mounted conduit, heavy duty ISI marked as per IS:9557 (Part I) 1980 for light points controlled by on switch, including HFFR insulated unsheathed unitary construction copper conductor 1.5 Sqmm nominal cross sectional area wire as earth continuity conductor up to common earth and connecting to earth dolly. Note :- Quoted rate shall deem to be included cost of cutting chasses in wall for concealing conduit and making good to match with existing finish. |
| 74 | Supply flame proof rotary type with termination box in LM6, 16 Amp, single pole 250V, complete all as specified and directed. |
| 75 | Supply and fixing for LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube right fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. |
| 76 | Supply and fixing for 240V, 10 KA \"C\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB, Complete with connection testing and commissioning. |
| 77 | Supply and fixing for 240V, 10 KA \"C\" curve miniature circuit breaker (MCB) of single poles & neutral and current carrying capacity 40 to 63 AMP, in the MCB DB, Complete with connection testing and commissioning. |
| 78 | S&F for MCB DB flame proof type 4 way, 220 V, 50 Hz, comprising 200 amps bus bar, neutral link, complete all as specified and directed. |
| 79 | Supply & fixing for exhaust fan flameproof 305 mm size 1500 RMP 1250 CFM, copper winding, power factor not less than 0.9 and all remaining accessories including safety pin, nut bolts, washers, suitable for 230 V, 50 Hz, single phase AC supply, earthing etc including necessary connection with flameproof conduit with 3 core 1.0 Sqmm flameproof wire and Including writing MES No all as specified and as directed. |
| 80 | M & L for shifting and refixing of split type AC (Indoor and Outdoor units) of any make and any type after servicing and charging of gas (M410a/R134a/R-22/r32) by testing the leakage in system by filling of Nitrogen gas upto 300 PSIG and repairing of leaking spot/joints with gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacuuming the system as existing and testing etc. complete all as specified & directed. Note : (a) Dismantling and refixing of split AC are including in quoted rate. (b) Drier capillary, copper tubing, refrigerant gas, insulation and LDPE pipe are inclusive in quoted rate. (c) Making hole and filling the hole on wall with PCC (1:2:4) type B0 (Using 12.5mm graded stone aggregate, 15mm thick rendering in cement mortar (1:3) good the disturbed surface with existing colour matching are inclusive in quoted rate. |
| 81 | M&L for sub main wiring using approved colour coding as per IS, with Zero Halogen Flame retardant (HFFR), smoke free, non toxic, non corrosive installation cable with UNILAY construction copper conductor 4.00 Sqmm (nominal area), single core, insulated and unsheathed stranded cable 1100 Volts grade 1S1-694 marked & including heavy duty, electric resistance welded (ERW) stove enameled surface mounted conduit, heavy duty ISI marked as per IS:9557 (Part I) 1980h , including HFFR insulated unsheathed unitary construction copper conductor 4.00 Sqmm nominal cross sectional area wire as earth continuity conductor up to common earth and connecting to earth dolly. Note:- (a) Two runs of 4.0 Sqmm cable and one run of 4 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment.(b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealing conduit and making good to match with existing finish. |
| 82 | M&L for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with andincluding PVC concealed conduit of medium grade with all fittingsincluding Modular metal flush box minimum 1.6 mm thick, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dollyand including cutting chases in walls / floors for concealed conduitandmaking good disturbed surfaces area by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash, complete all as specified and directed for the following:-Note: - Cutting chase to wall wherever required shall be included in the rate quoted for point wiring. |
| 83 | (a) One light, fan, bell point controlled by one switch single pole one way. |
| 84 | (b) One 3 pin switch socket outlet point 5 Amps on same board with other switch. |
| 85 | (c) All as per item No 81.01 here inbefore but with 2.5 sqmm copper conductor cable for One 5 Amps socket outlet on independent board. |
| 86 | All as per item No 81.02 here inbefore but with copper conductor cable for one 3 pin socket outlet, 15 amp independent, with cable 2.5 Sqmm size. |
| 87 | M&L for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 4 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with andincluding PVC concealed conduit of medium grade with all fittingsincluding Modular metal flush box, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 4 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dollyand including cutting chases in walls / floors for concealed conduitandmaking good disturbed surfaces by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash, complete all as specified and directed for Power socket 15 Amps on independent board. |
| 88 | M&L for Modular switch 1 way 6/10A, 1 module, flush button single pole, one way, complete as specified and directed by Engineer in Charge. |
| 89 | Supply and fixing of Modular socket outlet 2 in 1, 5 pin, 6/10 Amps flush type white finish, complete all as specifiedand as directed. |
| 90 | M&L for Modular socket outlet 2 in 1, 6 pins 6A and 16A, combined 2 module, complete all as specified and directed by Engineer in charge. |
| 91 | M&L for Modular switch 1 way 16A, 1 module, flush button single pole, one way, complete as specified and directed by Engineer in charge. |
| 92 | S & F for ceiling rose surface backlite 65x50mm 3 terminals, complete all as specified and directed. |
| 93 | S & F for Modular Fan step regulator, 120W - 2 module, complete all as specified and directed. |
| 94 | Supply and fixing 4 Module Gang box including Modular socket outlet 16 Ampsfor AC, 240 Volts flush type white finish including plug top 20 Amps with modular piano type switch 20 Amps and LED indicator (RED) incl concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 4 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with andincluding PVC concealed conduit of medium grade with all fittings and Modular white cover plate with frame 4 module to accommodate all theaccessories complete with internal connections, fixed with chromium plated screws and washers for switches and sockets, including 4 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dollyand including cutting chases in walls / floors for concealed conduitandmaking good disturbed surfaces by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash, complete all as specifiedand as directed. |
| 95 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed. |
| 96 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC |
| 97 | Supply and fixing factory made epoxy powder coated distribution board TPN way double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, stranded DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts, complete all as specified & directed. |
| 98 | Supply and fixing factory made epoxy powder coated distribution board SPN 08 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, stranded DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts, complete all as specified & directed. |
| 99 | Supply and fixing MCB single pole 240 volt \"C\" curve 10 KA 5 to 32 Amps capacity, all as specified and directed incl taking down old one. |
| 100 | Supply and fixing MCB single pole & neutral 240 volt \"C\" curve 10 KA 25 to 32Amps, complete all as specified and directed. |
| 101 | Supply and fixing MCB triple pole & neutral 240 volt \"C\" curve 10 KA 40 to 100Amps, complete all as specified and directed. |
| 102 | M&L for concealed sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6.0 Sqmm of voltage rating up to and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 25mm with all fittings and accessories, along with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6.0 Sqmm (green colour) as earth continuity conductor all as specified and directed. (Note : Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit) |
| 103 | M&L earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, buried directly in to ground ( earth pit) not less than 2.25 metres deep below GL with top edge of earth plate opt less attn. 1.50 m below ground levelsurrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, connected to GI lead strip of 32x6 mm dia.(7.50 m Long) by means of nuts, bolts and washers, check nuts of GIand protected by the GI pipe light grade 15 mm nominal bore(7.5 m long) for earth lead wire and watering pipe light grade of 20 mm nominal bore, 0.63 mm thick G I sheet funnel , wire mesh, earthing test pointetc complete including necessary earth work and excavation in any type of soil , PCC 1:2:4 type B1 earth pit and Precast RCC cover 65 mm thick duly reinforced with 6 mm dia. MS round bars @ 100mm C/C both ways, with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SI Part I, completeall as specified and directed and testing on completion.Note :- Ifthe desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. |
| 104 | Disconnecting & dismentling of damaged/unsv cable any type /make and Supply & laying (in repair) 35 Sqmm 4 core cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor using lugs/ferrul both end of cable and testing complete all as directed. |
| 105 | Excavation in trenches not exc 1.5 Mtr wide and n.exc 1.5 mtr in depth, getting out for electric cable complete in any type of soil, complete all as specified and directed.Note :-For the digging of soil , JCB machinewill not be allow at site, it will be done by labour only andcontractor will beresponsibleto repairthe existing cable, PCC plinth etc without extra cost which will be damaged during execution of work. |
| 106 | Supply and laying sub class \"B\" bricks laid dry and flat across the length of cable for protection of cable,complete all as specified and directed. |
| 107 | M & L for sand cushioning with Ganga Sand to underground cable (8 cm thick before laying and 15 cm thick after laying the cable, complete all as specified and directed. |
| 108 | M&L for boring under road horizontely of size 40 mm bore using GI pipe for passing of cable in road/path in hard/soft/ loose soil,complete all as specified and directed. |
| 109 | Supply, install,fixing and commissioning split type air conditioner of capacity 1.5 TR, five star rated, BEE 3.2 of capacity with cordless remote control unit and in built air ioniser, plasma filter for better indoor air quality, star rated suitable for wall mounted, single phase, 230/250 volt AC including breaking necessary hole in wall for fixing indoor and outdoor unit and making good to disturbed surfaces with cement mortar to match with existing finishes after commissioning, making necessary connections unplasticised PVC pipes medium duty 25 mm dia for draining out condensed water all as required including necessary connection, complete all as specified and directed. |
| 110 | S&F of type sheet metal single pole and neutral enclosure with two pin and earth plug and socket capacity 20-32 Amps modular type complete with one No SP MCB capacity 20-32 Amps, complete all as specified anddirected by Engineer-in-Charge. |
| 111 | Supply and fix of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 V to 270 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA, complete all as specified and directed. |
| 112 | Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. |