Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 09-12-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 16-12-2025 |
| 2 | 24-11-2025 | Amendment to BOQ and tender documents | BOQ | 09-12-2025 |
| Sl. No. | Item Description |
| 1 | Taking down chowkats or frames with shutters (without taking off shutters from the frames), area not exceeding 1.50 Sqm each including cutting holes for taking out hold fasts or dismantling brick work or cut holes for taking out hold fasts and making good disturbed surface to match with existing surface, complete all as specified and directed. |
| 2 | Taking down chowkats or frames with shutters (without taking off shutters from the frames), area exc 1.50 Sqm but not exc 4.0 Sqm each including cutting holes for taking out hold fasts or dismantling brick work or cut holes for taking out hold fasts and making good disturbed surface to match with existing surface, complete all as specified and directed. |
| 3 | S&F solid PVC door frame of size 50mm x 47mm, made out of 5mm plain colour PVC sheet reinforced with MS Square tube in opening and fixed at site, complete all as specified and directed. |
| 4 | S&F factory made solid panel PVC door shutter, 30mm thick (style), consisting of frame made out of MS tubes for top and bottom rail, MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, suppling & fixing in the frame at site, complete all as specified and directed. |
| 5 | S&F pressed steel frames of size 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. (thickness ofsheet shall be 1.25mm) and making good the wall with plaster in CM 1:6, complete all as specified and directed. |
| 6 | S&F pressed steel frames of size 105mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. (thickness ofsheet shall be 1.25mm) and making good the wall with plaster in CM 1:6, complete all as specified and directed. |
| 7 | M&L for mild steel framed work as in doors or gates of angle or other section withgusset plates, rails, braces, etc. complete, drilled for fixing of steel sheeting or other covering. Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging and also fastening and fixing complete angles as in cup boards (40x40x5mm), conforming to FE-410-W Gde-E-250 Quality A, complete all as specified and directed. |
| 8 | M&L for mild steel framed work such as grills, gratings etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work including welding, conforming to Fe-290 Gde-E-165, complete all as specified and directed. |
| 9 | M&L for PCC 1:3:6 type C-0 (using 12.5mm graded stone aggregates) as filling in hollow pressed steel frame, hold fasts and similars articles, complete all as specified and directed. |
| 10 | S&F plain framed, panelled shutter 35mm thick, 2nd class hard wood (two panel) with lock rail and panel of 9mm thick BWP commercial ply or 12mm thick veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (Part I), kiln seasoned and chemically pressure treated, complete all as specified and directed. |
| 11 | S&F 35mm thick 2nd class hardwood glazed and Skelton shutter, open rebated and prepared to receive glass, gauge etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, stiles and rails as specified in SSR Part-I Cection 8 Clause 8.20 (b), complete all as specified and directed. |
| 12 | M&L for 18/19mm thick prelaminated particle board, medium density, flat pressed single layer type or three layer type with BWR type adhesive, complete all as specified and directed. |
| 13 | S&F stainless steel wire cloth, 0.36mm dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed. |
| 14 | S&F 150mm size helical double action door spring, mild steel with steel wire spring, stove enameled black, complete all as specified and directed. |
| 15 | S&F 75mm long mild steel butt hinges, medium weight, cold rolled, complete all as specified and directed. |
| 16 | S&F 300mm long aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) andfixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolt of extruded sections or cast aluminium alloy, complete all as specified and directed. |
| 17 | S&F 250mm long aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) andfixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolt of extruded sections or cast aluminium alloy, complete all as specified and directed. |
| 18 | S&F aluminium anodised barrel tower bolts of extruded section of size 200mm, complete all as specified and directed. |
| 19 | S&F aluminium anodised barrel tower bolts of extruded section of size 150mm, complete all as specified and directed. |
| 20 | S&F 100mm long alunminium handle, cast type, oval shape, complete all as specified and directed. |
| 21 | S&F 150mm long alunminium handle, cast type, oval shape, complete all as specified and directed. |
| 22 | S&F 100mm size hasp and staple, safety type, aluminium anodised including bolt to hinge plate and fixed with screws, complete all as specified and directed. |
| 23 | S&F 125mm long alunminium handle, cast type, oval shape, complete all as specified and directed. |
| 24 | S&F aluminium anodised barrel tower bolts of extruded section of size 125mm, complete all as specified and directed. |
| 25 | S&F 30mm (when opened) continuous (piano) hinges, mild steel, bright finish or electrogalvanised, complete all as specified and directed. |
| 26 | S&F 150mm size door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, complete all as specified and directed. |
| 27 | S&F powder coated aluminium frame for doors, sliding windows, ventilators with one or more rebates including joining cleats for fixing etc, complete all as specified and directed. |
| 28 | S&F powder coated (of approved colour) aluminium (minimum thickness of powder coated 50 micron) as in shutter of windows, ventilators, openable/ louvers, fixed/sliding type without sash bars, aluminium section not less than 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, aluminium snap beading, screws, rolling for smooth moving & locking arrangement etc. fixed to wall including preparation of disturbed portion both side (internal & external surfaces of wall) to match with existing surface and all sides of aluminium frame shall be sealed with silicon sealent (inner/outer face), complete all as specified and directed. |
| 29 | S&F 4mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane, complete all as specified and directed. |
| 30 | S&F 4mm thick figured glass, pin head type and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane, complete all as specified and directed. |
| 31 | Cutting holes in brick walls in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required, exc half brick but not exc one brick thick wall, complete all as specified and directed. |
| 32 | M&L for preparation of new steel or iron surfaces of any description, exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed. |
| 33 | M&L for preparation of new or old surfaces of wood and wood based materials or steel / iron work of any description and girth and treated with tar or coal tar black paint, complete all as specified and directed. |
| 34 | Demolition of cement concrete of any description and in any position, not otherwise specifically provided for, complete all as specified and directed. |
| 35 | Demolition of cement concrete (un-reinforced) as in roofs of existing water proofing treatment of any type and thickness, complete all as specified and directed. |
| 36 | M&L for 25mm thick plain cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) as floor, sub base etc, finished the surface even and smooth, complete all as specified and directed. |
| 37 | M&L for 7-8mm thick non skid ceramic coloured tiles (square / rectangular), area of each tile exceeding 0.11 Sqm but not exc 0.18 Sqm as in floors with skirtings, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid/ fixed over and including 15mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 38 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), terrazo, dado and skirting etc. on brick, concrete or stone walls including racking out joints, hacking for key and scrubbing down and removing serviceable tiles to store and rubbish off the premises etc, complete all as specified and directed. |
| 39 | M&L for glazed ceramic coloured tiles of size 450mm x 300mm x 7mm, fixed on verticle surfaces, fixed over and including 10mm thick plaster/ backing coat in CM 1:3, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, complete all as specified and directed. |
| 40 | M&L for 18-20mm thick granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window cills, cooking platforms and the like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and including grinding and polishing with rounding to edges of stone slabs one edg complete, laid/ fixed over and including 20mm thick screed be/ plaster CM 1:4, complete all as specified and directed. |
| 41 | M&L for 18-20mm thick machine cut kota stone slab flooring, jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, grinding and polishing complete and rounding of edges, laid over and including 20mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 42 | M&L for 18-20mm thick machine cut kota stone slab as in skirtings, dados, walls, jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, grinding and polishing complete and rounding of edges, fixed over and including 10mm thick plaster in CM 1:3, complete all as specified and directed. |
| 43 | S&F in replacement PVC connection of 15mm dia with PTMT nuts of length 600mm, complete all as specified and directed. |
| 44 | S&F in replacement stop valve, chromium plated, cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends, fixed to 15mm bore iron pipe, complete all as specified and directed. |
| 45 | S&F in replacement shower rose, brass, chromium plated, 125mm dia with or without swivel joint, with and including CP brass arm and wall flange, fixing to steel pipe or union, complete all as specified and directed. |
| 46 | S&F in replacement stop valve (concealed type), fancy type, chromium plated, cast copper alloy with long shank & cup etc, fixed to 15mm bore iron pipe, complete all as specified and directed. |
| 47 | S&F in replacement chromium plated tubular towel rail, \"D\" type, 600mm long between flanges, complete all as specified and directed. |
| 48 | S&F in replacement soap dish of stainless steel, size 160x160x90mm, fixed to wall with chromium plated brass screws, complete all as specified and directed. |
| 49 | S&F in replacement of 15mm dia bib tap, cast copper alloy, fancy type, chromium plated with crtuch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule, complete all as specified and directed. |
| 50 | S&F brass CP mixer for mixing hot & cold water,screwed down for 15mm bore iron pipe and fixed, suitable for wash hand basin, complete all as specified and directed. |
| 51 | S&F sink mixture with regular swinging spout wall mounted with connecting legs and wall flanges, fixed to 15mm bore iron pipe, complete all as specified and directed. |
| 52 | S&F brass CP wall mixer for mixing hot & cold water, screwed down for 15mm bore iron pipe and fixed with wall flange, complete all as specified and directed. |
| 53 | S&F stainless steel plate rack of size 750mm x 900mm x 250mm, made out of 1.0mm thick stainless steel sheet with steel shelves and hanging arrangement for utensil with SS screws, complete all as specified and directed. |
| 54 | S&F in replacement kitchen sink with drainage board, made of stainless steel 1mm thick, overall size 915mm x 460mm, bowl size 410mm x 330mm x 160mm with plugs including bedding in cement mortar and fixing cantilever brackets, 32mm dia CP waste coupling & PVC waste pipe, complete all as specified and directed. |
| 55 | S&F bevelled edge looking mirror of size 600mm x 450mm of selected quality glass, mounted on 5mm thick PVC sheet and fixed to rawl plugs with chromium plated brass screws and cup washers, complete all as specified and directed. |
| 56 | S&F mirror cabinet PTMT of size 450mm x 600mm with magnetic looking arrangements, fixed with and including chromium plated brass screws and PVC rawl plugs, complete all as specified and directed. |
| 57 | S&F 25mm dia stainless steel curtain rod with brackets/ wall brackets and knobs at both ends as per site requirement including taking down old existing PVC conduit pipes with accessories, complete all as specified and directed.Note :- The cost of brackets and knobs shall be deemed to include in the quoted rates. Nothing extra shall be paid on this account. |
| 58 | Taking up or down 15mm bore steel tubing and connections including cleaning for refixing or removal to store, complete all as specified and directed. |
| 59 | Taking up or down 20mm bore steel tubing and connections including cleaning for refixing or removal to store, complete all as specified and directed. |
| 60 | Taking up or down 25/32mm bore steel tubing and connections including cleaning for refixing or removal to store, complete all as specified and directed. |
| 61 | S&F 15mm bore steel water tubing, medium grade, galvanised with all fittings and fixtures, fixed to wall or ceiling or laid in floors, complete all as specified and directed. |
| 62 | S&F 20mm bore steel water tubing, medium grade, galvanised with all fittings and fixtures, fixed to wall or ceiling or laid in floors, complete all as specified and directed. |
| 63 | S&F 25mm bore steel water tubing, medium grade, galvanised with all fittings and fixtures, fixed to wall or ceiling or laid in floors, complete all as specified and directed. |
| 64 | Re-fixing of old 15mm bore steel water tubing and connections in new or old position (walls, ceiling, floors etc.) including required GI fittings, complete all as specified and directed. |
| 65 | Re-fixing of old 20mm bore steel water tubing and connections in new or old position (walls, ceiling, floors etc.) including required GI fittings, complete all as specified and directed. |
| 66 | Re-fixing of old 25mm bore steel water tubing and connections in new or old position (walls, ceiling, floors etc.) including required GI fittings, complete all as specified and directed. |
| 67 | S&F 32mm bore steel water tubing, medium grade, galvanised iron for spout, laid in sunken portion / floors, complete all as specified and directed. |
| 68 | Taking down rain water pipes and eaves gutters (any size and pattern) including all fittings, heads shoes, bends, swan necks etc. including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and directed. |
| 69 | S&F in replacement cast iron floor trap with SS grating including jointing with solvent cement, 75mm diameter of outlet, complete all as specified and directed. |
| 70 | Dismantling of 100mm bore cast iron or RCC drain pipes including all fittings and accessories and in any position, complete all as specified and directed. |
| 71 | Dismantling of 75mm bore cast iron or RCC drain pipes including all fittings and accessories and in any position, complete all as specified and directed. |
| 72 | S&F 75mm bore cast iron spun pipes, double socketed in any length with cement joints, fixed to walls with MS clamps of suitable size, complete all as specified and directed. |
| 73 | S&F 100mm bore cast iron spun pipes, double socketed in any length with cement joints, fixed to walls with MS clamps of suitable size, complete all as specified and directed. |
| 74 | S&F cast iron bend, any radius, suitable for 100mm bore cast iron pipe, complete all as specified and directed. |
| 75 | S&F cast iron bend, any radius, suitable for 75mm bore cast iron pipe, complete all as specified and directed. |
| 76 | S&F cast iron branch piece single (single \"T\"), equal or unequal, ordinary or inverted (spigot or socket type) or with parallel branches, suitable for 100mm bore cast iron pipe, complete all as specified and directed. |
| 77 | S&F cast iron branch piece double (double \"T\"), equal or unequal, ordinary or inverted (spigot or socket type) or with parallel branches, suitable for 100mm bore cast iron pipe, complete all as specified and directed. |
| 78 | S&F cast iron branch piece single (single \"T\"), equal or unequal, ordinary or inverted (spigot or socket type) or with parallel branches, suitable for 75mm bore cast iron pipe, complete all as specified and directed. |
| 79 | S&F cast iron branch piece double (double \"T\"), equal or unequal, ordinary or inverted (spigot or socket type) or with parallel branches, suitable for 75mm bore cast iron pipe, complete all as specified and directed. |
| 80 | S&F cast iron vent cowl, suitable for 100mm bore cast iron pipe, complete all as specified and directed. |
| 81 | S&F cast iron vent cowl, suitable for 75mm bore cast iron pipe, complete all as specified and directed. |
| 82 | S&F in replacement gun metal globe or gate valve with iron wheel head, screwed both ends for 20mm bore iron pipe, complete all as specified and directed. |
| 83 | S&F in replacement wash down water closet pan (pedastal pattern) complete with \"P\" trap including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc. including PVC seat cover with aluminium hinging device, complete all as specified and directed. |
| 84 | S&F in replacement PVC low level cistern of 10 ltrs capacity with top push button inclusive of brackets and PVC bend long type and connecting to flush pipe of any size and pattern with inlet ball valve, float and handle, complete all as specified and directed. |
| 85 | S&F glass corner set of three of size 12\"\" x 9\"\" x 6\"\" with stainless railling and fixed with stainless steel screws, complete all as specified and directed. |
| 86 | S&F in replacement wash hand basin of size 550mm x 400mmm vitreous china, white, pedestel type including MS brackets, 32mm dia brass chromium plated waste coupling, CP fancy type pillar tap and PVC waste pipe of 32mm dia, complete all as specified and directed. |
| 87 | Taking down old PCC tiles form roof and removing bedding of any description, complete all as specified and directed. |
| 88 | M&L for 15mm thick rendering in cement mortar 1:3 as on roof (Accessable / Non Accessable) surfaces with using water proofing compound, finished the surface even and smooth without using extra cement, complete all as specified and directed.Note :- WPC shall be measured and paid separately under respective items of BOQ. |
| 89 | M&L for factory made, glossy finish, coloured chequred cement concrete tile of size 30cm x 30cm x 25mm thick each, machine pressed as in floors, set and jointed in neat cement slurry and jointing with white/ grey cement & pigments to match with tiles, laid/ fixed over and including 15mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 90 | Dismantling or taking down existing roof treatment of any description and any type, complete all as specified and directed. |
| 91 | Roughening surfaces of old concrete floor by picking, sweeping, clean and washing down with water to remove dust etc. and brushing neat cement slurry with 3.0 Kg of cement per Sqm, complete all as specified and directed. |
| 92 | Supply only integral water proofing compound. |
| 93 | M&L for apply bituminous primer confirming to IS-3384 @ 0.40 Kg/Sqm on prepared surface on sunny day. After the primed surface has dried then apply a coat of hot blown 85/25 penetration grade blown bitumen, confirming to IS-702 @ 1.20 Kg/Sqm on the surfaces then provide APP (Atactiic Polypropylene) modified polymeric five layered membrane with central core of 100 micron high molecular high density firm, minimum weight of membrance shall be 3 Kg/Sqm. APP membrance will be laid across the slope from lowest line sloping roof towards ridge with minimum end lap of 150mm & side lap of 75mm bonded with hot blown bitumen, over the APP membrance apply semi hot blown 85/25 penetration grade bitumen @ 1.20 Kg/Sqm and blinded with fine sand in dry condition @ 0.50 Kg/Sqm dusted over the bitumen coat with two coats of aluminium paint, complete all as specified and directed.Note :- The laying of the membrane shall be got done by authorized applicator of the membrane manufacturer. |
| 94 | Making benching with and including PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) with using WPC along side wall, adjoining to roof kerb in concave shape, complete all as specified and directed.Note :- WPC shall be measured and paid separately under respective items of BOQ. |
| 95 | Taking down cement plaster on brick walls, stone masonry/ walls, concrete surfaces etc. including raking out joints, hacking for key, scrubbing down with water etc., complete all as specified and directed. |
| 96 | M&L for 10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6, finished the surface even and smooth without using extra cement, complete all as specified and directed. |
| 97 | M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 with using water proofing compound, finished the surface even and smooth without using extra cement, complete all as specified and directed.Note :- WPC shall be measured and paid separately under respective items of BOQ. |
| 98 | M&L for 5mm thick rendering in CM 1:3 as on ceiling, finished the surface even and smooth without using extra cement, complete all as specified and directed. |
| 99 | M&L for cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in chajjas, roof projections, drops and similar work, complete all as specified and directed. |
| 100 | Demolition of brick work or stone boulder masonry, built in cement mortor including all quoins, arches, pillars etc, complete all as specified and directed. |
| 101 | M&L for half thick brick work with sub class \"B\" brick, old size, built in CM 1:4, complete all as specified and directed. |
| 102 | M&L for brick work with sub class ‘B’, old size bricks, straight or curved on plan exc 6 mtr mean radius, built in CM 1:6, complete all as specified and directed. |
| 103 | M&L for 75mm thick cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in plinth protection, laid in alternate ways (not exc 2.0 Sqm each) and finished the surface even and smooth without using extra cement, complete all as specified and directed. |
| 104 | Demolition of RCC of any description such as kitchen chimney, chajja, shelves, OHT Tanks etc. and in any position, not otherwise specially provided for(reinforcement cut as required to facilitate demolition), complete all as specified and directed. |
| 105 | M&L for reinforced cement concrete 1:1.5:3 (Nominal Mix) type A-1 as in slabs supported on walls, beams and column in floors, roofs, landings, balconies, deck slabs and in shelves etc, complete all as specified and directed. |
| 106 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips, complete all as specified and directed. |
| 107 | M&L for mild steel TMT bars, 6-8mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips, complete all as specified and directed. |
| 108 | Use and waste of formwork to rough finished concrete soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or sloping), complete all as specified and directed. |
| 109 | Use and waste of formwork to edges of concrete (rough finished) flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work, exc 10cm but not exc 20cm wide, complete all as specified and directed. |
| 110 | Dismantling water tank and remove to store of capacity exc 500 ltrs but not exc 1000 Ltrs with all necessary fittings, complete all as specified and directed. |
| 111 | S&F 1000 ltrs capacity tripple layered rotational moulded polyethylene water storage tank, white colour (cylindrical vertical with closed top) with, hoisted and fixed in position including nipple inlet and outlet and conneting pipes, complete all as specified and directed. |
| 112 | S&F ball valve high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball, screwed for 20mm bore iron pipe (min weight 210 gms), complete all as specified and directed. |
| 113 | M&L for preparation of newly plastered surfaces of walls and smoothening the surface with sand paper / mechanised sanding and applying two coats of oil bound distemper over and including a coat of primer over and 2-3mm thick wall care putty, complete all as specified and directed. |
| 114 | M&L for preparation of new plastered surfaces of ceiling and applying two coats of white wash, complete all as specified and directed. |
| 115 | M&L for preparation of new or old surfaces of any description and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 Gram/litre and UV resistance as per IS-15489:2004, alkali & fungal resistance, dirt resistance, exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer @ 0.90 litre/10 Sqm over and including 2-3mm thick wall care putty, complete all as specified and directed. |
| 116 | S&F in replacement brass eye door viewer (magic eye), fixed in position for door shutters, complete all as specified and directed. |
| 117 | S&F 50mm wide rubber sheet of thickness not less than 3mm, fixed with stainless steel screws at the bottom of door shutters as in door cill, complete all as specified and directed. |
| 118 | S&F stainless steel fancy type peg set of four, fixed in position with SS screws and wooden/PVC gutties, complete all as specified and directed. |
| 119 | M&L for rubbing, grinding and polishing existing (old) kota stone flooring, complete all as specified and directed. |
| 120 | S&F 110mm bore PVC (SWR) pipes in any length with rubber ring joints, fixed to walls with MS clamps of suitable size, fixed at any height, complete all as specified and directed. |
| 121 | Taking down carefully the existing copper / aluminium point wiring of any size and type by disconnecting from the either terminals complete with switches, sockets, ceiling rose, regulators, bell etc. by unscrewing and removing materials to store for keeping in safe custody for re-use or for taking credit and making good to disturbed surface of walls, floors etc. to match with existing surfaces, complete all as specified and directed. |
| 122 | M&L for point wring for one light / fan point, controlled by one switch with 1.5 Sqmm (nominal area) PVC insulated and PVC unsheathed multi-stranded copper conductor cable FRLSH and including concealed PVC conduit of 25mm dia, medium Grade ISI marked and including suitable size new steel sunken boxes, laminated sheet cover plate for fixing of switches, sockets as required, flush to surface and including PVC insulated unsheathed 1.5 Sqmm copper conductor cable FRLSH connected to common earth dooly complete including cutting, chasing and making good disturbed surfaces of walls, floors etc. to match with existing surfaces, complete all as specified and directed. |
| 123 | All as per serial item No. 122.00 here-in-above but for one bell / buzzer point, controlled by one other switch or independent one bell switch. |
| 124 | All as per serial item No. 122.00 here-in-above but for one 3/5 pin socket outlet, 6 Amps on independent board. |
| 125 | All as per serial item No. 122.00 here-in-above but wire size 2.5 Sqmm to controlled the 3/5 Pin 5/15 Amps socket outlet on independent board and providing earth continuity wire using PVC insulated, FRLSH 1100 volts grade unsheathed single core multistranded copper conductor cable of size 2.5 Sqmm. |
| 126 | All as per serial item No. 122.00 here-in-above but for 3 pin socket outlet 5 Amps on same board. |
| 127 | All as per serial item No. 122.00 here-in-above but one light/ fan point, controlled by two way switch. |
| 128 | S&F switch piano, flush type, single pole, one way, 5 Amps, complete all as specified and directed. |
| 129 | S&F socket outlet, 2 in 1, 3 pin, 5 Amps, complete all as specified and directed. |
| 130 | S&F switch piano, flush type, single pole, one way, 15 Amps, complete all as specified and directed. |
| 131 | S&F socket outlet, 2 in 1, 3 pin, 5 and 15 Amps, flush type, complete all as specified and directed. |
| 132 | S&F bell push, flush type, 5 Amps, complete all as specified and directed. |
| 133 | S&F switch piano, flush type, single pole, two way, 5 Amps, complete all as specified and directed. |
| 134 | S&F ceiling rose, 3 terminal, PVC / polycarbonet, isolated body, complete all as specified and direcetd. |
| 135 | S&F electronic fan regulator, stepped type, 240 Volt, flush type, suitable for 1200/1400mm sweep ceiling fan, complete all as specified and direcetd. |
| 136 | S&F bell, ding dong type, AC, 230 volts, single pole, complete all as specified and directed. |
| 137 | S&F in replacement 20/22 Watt LED light fitting, 230 Volts, high quality LED batten with aluminum extrusion housing with PC diffuser, CRI > 80, efficacy : 120 Lm/W, IP-20 complete including connecting up with flexible copper wire of suitable size from ceiling rose to LED, complete all as specified and directed. |
| 138 | S&F in replacement LED light fitting mirror type with high out put diffuser, 2 feet, 10/12 Watt, 220 V, AC, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, with CRI >, 80 efficacy : 120 Lm/W , IP-20, complete all as specified and direcetd. |
| 139 | S&F in replacement LED light fitting with high out put diffuser, 1 feet, 5 Watt, 220 V, AC, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, with CRI >, 80 efficacy : 120 Lm/W , IP-20, complete all as specified and direcetd. |
| 140 | S&F ceiling fan complete with blades, down rod with remote control opetated and accessories, 230 Volts, 1200mm sweep, min air delivery 210 CFMwith service value 6.00 BEE Five star rated with brushless direct current (BLDC) motor, complete all as specified and directed. |
| 141 | S&F in replacement LED bulk head (6500K) fitting of 10 Watt with CRI >, 80 efficacy : 120 Lm/W , IP-20, surface mounting type extruded aluminium body with diffuser, complete all as specified and directed. |
| 142 | S&F in replacement building security LED light 45 Watt, 230 Volts AC (110 Ln/W), AC, enegry saving long life, made up pressure die cast aluminum housing with separate driver, compartment toughened glass having efficacy with IP-66 complete alongwith suitable size bracket, nuts, bolts and clamps, complete all as specified and directed. |
| 143 | Taking down ceiling / exhaust fan, ceiling cable end, dismantling blades and removing fan and blades to and deposit to MES store or handover to unit MES NCO for kept in safe custody, complete all as specified and direcetd. |
| 144 | S&F exhaust fan, heavy duty, steel body, copper windind, double bearing, AC, single phase, size 300mm sweep, 4 blades with iron frame and iron louver and connection, complete all as specified and directed. |
| 145 | S&F PVC body air freshner fan, copper winded, AC, single phase, size 150mm sweep with louver including making necessary hole for fixing of fan, complete all as specified and directed. |
| 146 | Hanging / fixing only ceiling fan and connecting up and including provision of cable from ceiling rose or connector to fan obtained from serial item No. 143.00 here-in-above, complete all as specified and direcetd. |
| 147 | M&L for earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm x 6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to earth plate with GI wire of 4mm dia by means of nuts, bolts and washers, check nuts of galvanized iron or steel including 15mm dia GI pipe light grade upto 1.5 mtr below GL for protection pipe, excavation and earth work, charcoal dust, common salt, PCC 1:3:6type C-1 chamber with cover and RCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates), reinforced with 6mm dia round bars @ 75mm c/c both way with MS handle 12mm dia, PGI funnel and wire mesh all as shown in electrical plate No. 3 of SSR Part-I, connected to earthing test point terminal including testing on completion, complete all as specified and directed. |
| 148 | S&F sheet metal VTPN DB, suitable for 125 Amps MCCB, double door, 04Way (optimum F1+12) with metaldoor,415 Volts grade, IP-42 Protection Grade, fixed/ flush to wall and connections should be provide with necessary reducer lugs and making good disturbed surface to match with existing surfaces, complete all as specified and directed. |
| 149 | S&F MCCB 4 Pole, 415 Volts, adjustable type, 125 Amps with breaking capacity, 16 KA, complete all as specified and directed. |
| 150 | S&F in replacement SPN sheet metal steel powder coated distribution board for MCBs fitted with bus bar neutral link earth bar and din rail suitable for use on 240 Volts, 50Hz, double door, DB system, 8 way, complete all as specified and directed. |
| 151 | S&F in replacement of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps, 240 Volt, complete all as specified and directed. |
| 152 | S&F MCB SPN 40 Amps, 240 Volts, repturing capacity 10 KA, \"C\" Series, complete all as specified and directed. |
| 153 | S&F MCB SP, 6 to 32 Amps, 240 Volts, repturing capacity 10 KA, \"C\" Series, complete all as specified and directed. |
| 154 | S&F MCB SP, 63 Amps, 240 Volts, repturing capacity 10 KA, \"C\" Series, complete all as specified and directed. |
| 155 | Taking down serviceable/ unserviceable electric meter including meter box from existing position carefully for refixing including making good to disturbed surfaces to match with existing surfaces, complete all as specified and directed. |
| 156 | M&L for submain wiring with two run single core 6.0 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 Volts grade including 25mm dia in PVC concealed conduit/ PVC casing & caping, medium grade, ISI marked with all accessories such as Tees, elbows, junction boxes etc. as required, fixed on wall alongwith one run of 6.0 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board, complete including taking down unserviceable submain of any type/size and testing on completion, complete all as specified and directed.Note :- Two run of 6.0 Sqmm and one run 6.0 Sqmm cable and one run of PVC conduit / PVC casing & caping shall be measured as one unit/RM. |
| 157 | M&L for submain wiring with two run single core 4.0 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 Volts grade including 25mm dia in PVC concealed conduit/ PVC casing & caping, medium grade, ISI marked with all accessories such as Tees, elbows, junction boxes etc. as required, fixed on wall alongwith one run of 4.0 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board, complete including taking down unserviceable submain of any type/size and testing on completion, complete all as specified and directed.Note :- Two run of 4.0 Sqmm and one run 4.0 Sqmm cable and one run of PVC conduit / PVC casing & caping shall be measured as one unit/RM. |
| 158 | Supply, laying/ fixing and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 Core, as in trenches/ floor/ pole/ GI pipe complete including cutting/ chasing to any surface and making good to the disturbed surface to match with existing surfaces and including taking out/ down existing cable, complete all as specified and directed. |
| 159 | Excavation in trenches in any type of soil, not exc 1.5 mtr deep and not exc 1.5 mtr wide for laying of under ground cable, pipe, electric pole and getting out, complete all as specified and directed. |
| 160 | Returning, filling in including spreading, leveling and well ramming in layers not exc 25cm in thick, complete all as specified and directed. |
| 161 | Removing excavated material to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed. |
| 162 | Supply and laying 20 to 100mm dia DWC pipe (double wall corruguated) HDPE, PE-100, PN-4, confirming to IS:14930 (Part-II) alongwith necessary snap fit coupler for inter connection andsize suitable protection for LT cable, complete all as specified and directed.Note :- Dia of DWC pipe shall be decided by EIC as per site requirement and cost for the same shall be deemed to include in the quoted rates. |
| 163 | S&F in repair rigid non - metalic PVC casing caping of 25/12mm inclusive of all elbow, tees,etc complete all as per the direction of Engr-in-Charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail