| 1 | Attending of day to day complaints, petty repair wks of E/M nature pertains to internal electrification/ external electrification/ internal electric wiring, comprise of checking of existing electrical circuits / items i.e. various lighting luminaries, appliances, exhaust fan, switch/socket & other accessories, DB / MCCB incomer, MCB / MCCB etc for continuous electrical supply; checking of LT/ HT overhead/underground electric lines with necessary excavation/ refilling as required, checking of LT Panels for detection of nature of fault / defect; carrying out minor repairs etc as required to make the items functional or to restore electric supply with and incl tightening of loose/broken connections/ overhead/underground electric lines, insulating the naked wire, opening of bakelite sheet/cover plates/DB etc and refixng the same after necessary repairs, checking of street/security lights by taking down and refixing the same after necessary repair, replacing defective items provided under relevant item(s) here-in-after or any item issued under Sch \"B\" free for fixing, with and incl petty repairs items/materials i.e. fuses, thimbles (upto 10 sqmm single core wire), small wires of any size and description upto 1.5 m, lugs, screw, washer, nut bolts etc with and including cutting of bakelite sheet for fixing of accessories, making all electric connection etc, in Md/OTM Accn andin any location within the area of Ranikhet Cantt (Half Moon, Alma, S&T, Butchry, Adm top, DHQ, MH area, Jhula Devi area, Ranijheel, Dulikhet, walna range, Majhkhali and Ghingharikhal area) and, by deploying sufficient number of qualified electricians & helpers alongwith suitable T&P, safety equipment & other necessary devices, every day including Sunday and Holiday, during time from 7:00 AM to 11:00 PM, complete all as specified and directed. |
| 2 | Note for item No 01 : (i) All the complaint(s) received will be lodged & rectified by the contractor rep and will have to maintain a proper record as directed in complain register and in complain slip.Note: (a) Complain slip and complain register will be provided by the contractor without any extra charge.(b) Complain register will be produced on daily basis to JE and Engineer-in-charge(c) Contractor or his tradesmen fails to attend and rectify the complaint(s), as described earlier, on same day or any stipulated time given by the JE/ Engineer-in-charge, the penal recovery / penalty of Rs. 200.00 (Rupees Two Hundred only) per complaint per day for first day and after that Rs. 500.00 (Rupees Five Hundred only) per complaint per day shall be recovered from the contractor’s dues. |
| 3 | Contractor shall provide and deploy adequate experienced professional to carry out day to day complaints and tradesman will remain present in the station in 2 shifts, shift1 from 0700Hrs to 1500 Hrs from Monday to Sunday and shift 2 from 1500Hrs to 1100Hrs from Monday to Sunday.In case of any breakdown/ emergency, contractor shall make arrangement to attend and rectify the complaints in odd hours on Sunday/ holiday also.The rates quoted in sch \"A\" respective items shall be deemed to be included and nothing extra shall be admissible on this account. Note: whatever be the nature of electrical complaint the whole sole rectification responsibility lies with the contractor. |
| 4 | The quoted rate are deemed to be inclusive of petty repairs items/materials i.e. fuses, small wires single / twin / three core up to 1.0 sqmm, MCB connecting links, DIN rails, screws, nuts, bolts & washers, aluminium / copper lugs / thimbles, insulation tape, CTC and cotton waste for cleaning burnt area etcas required at site, during execution of petty repair wks or attending complaints. Nothing extra shall be admissible on this account at any stage.Any major items/materials which are required to be replaced with new one i.e. switch, socket, bell push, lamp holder, ceiling rose, fan regulator, modular accessories, ballast / chock, lamp, bakelite sheet, MCCB, MCB, casing & caping, plug top, light luminaries, PVC box, conduits etc shall be either measured & paid separately under respective item(s) or issued for \"Free for Fixing only\". |
| 5 | Quoted rate shall deemed to be inclusive of cutting chases for concealed conduit and insertion of metal boxes in the wall wherever required and making good of disturbed wall surfaces with cement plaster, putty and OBD etc to match with the existing surfaces and nothing extra shall be admissible on this account.The cost of transportation (to and fro) and other necessary T&P (i.e. screw driver set each sizes, line tester, combination and cutting pliers, cutting knife, hand gloves suitable for available voltages, Test lamp with conductor and holder etc), equipment and safety gear shall be arranged / brought by contractor to complete the job and no extra cost shall be paid to the contractor in this effect. |
| 6 | All as per item no 1 here in before but for area Chaubattia Cantt (Hanuman mandir, Bde, 23WEU, 15 Garh, Bde signal, 232 Fd Wksp, MES area, Ht Point and Nagpani) |
| 7 | All as per item no 1 here in before but for area Kausani cantt |
| 8 | All as per item no 1 here in before but for area Almora cantt |
| 9 | Supply & Fix in replacementcall bell ding dong AC, 230V single pole complete all as specified and directed, |
| 10 | Supply & Fix in replacementbell pushpiano flush type single pole, one way 5 Amp complete all as specified and directed. |
| 11 | Supply & fix in replacement MCB single pole, 240 volts, 5 to 32 Ampere, rupturing capacity 10 KA, ‘B’ curve type including taking down complete all as specified and directed. |
| 12 | Supply & fix in replacement MCB single pole and neutral, 240 volts, 25-32 Ampere, rupturing capacity 10 KA,\"B’ curve type including taking down complete all as specified and directed. |
| 13 | Supply & fix in replacement MCB TPN, 415 volts, AC, B curve, 10 KA , 63 to 100Amps. |
| 14 | Supply & fix in replacement service connection cable, 1100 volts grade heavy duty PVC insulated aluminium conductor, 16 Sqmm 2 core size, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mmsuspensionwire, one twin core cable flat or circular, complete all as specified and directed. |
| 15 | Supply & fixHigh in replacement quality LEDlighting fixture mirror type with high output diffuser 2 feet 1x 10 Watt. 220V AC,complete with polycarbonate tube, white/warm white suitable for mirror light internally pre wired of 1.5 sqmm three core flexible cable complete all as specified & directed. |
| 16 | Supply & fix in replacement High quality LED T8tube rod 20 Watt (with inbuild driver) with single side connection including connection with wire of 1.5 sqmm twin twisted flexible cable complete all as specified & directed. |
| 17 | Supply & fix switch piano flush type single pole, one way 5/6 Amp complete all as specified and directed. |
| 18 | Supply & fix socket out letmulti 5 pin, 5/6 Amps, flush type complete all as specified and directed. |
| 19 | Supply & fix switch piano flush type single pole, one way 15 Amp complete all asspecified and directed. |
| 20 | Supply & fix socket out let 2 in1,3 pin, 5 and 15 Amp, flush type complete all as specified and directed. |
| 21 | Supply & Fixlamp holder angle type PVC/Poly carbonate type insulated body with back plate suitable for batten/wall fitting complete all as specified and directed. |
| 22 | Supply & Fixmodular switch 6/10 A , 1 module, one way complete all as specified and directed. |
| 23 | Supply & Fixmodular socket out let6/10 Amps,2module 2/3 pin combined complete all as specified and directed. |
| 24 | Supply & Fixmodular switch 16/20A , 1 module, one wayomplete all as specified and directed. |
| 25 | Supply & Fixmodular socket out let16/20 Amps,2module,2/3 pin combined complete all as specified and directed. |