| Sl. No. | Item Description |
| 1 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n.exc 1.50 sqm each complete all as specified and directed. |
| 2 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm and n.exc 4 Sqm each complete all as specified and directed. |
| 3 | Taking down cement plaster on brick walls or stone walls of any description etc including raking out joints, hacking for key, scrubbing down with water etc, rubbish off the premises complete all as specified and directed. |
| 4 | Dismantling of brick work built in cement mortar including all quoins, arches, pillars etcand removal of debris/rubbish off the premises etc complete all as specified and directed. |
| 5 | Dismantling floor, hearth or walls tilling and terrazo topping including cement mortar bedding ( but not backing),rubish off the premises complete all as specified and directed. |
| 6 | Taking up or down steel water tubing and connections including cleaning for refixingof pipe 15mm bore or removal to store complete all as specified and directed. |
| 7 | Taking up or down steel water tubing and connections including cleaning for refixingof pipe 20mm bore or removal to store complete all as specified and directed. |
| 8 | Surface dressing n.exc (not exceeding) 30cm deep and averaging 15 cm deep and getting out in soft/loose soil, complete all as specified and directed. |
| 9 | Excavation in post holes (or similar holes) each n.exc. 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50m, in soft/loose soil and making good surfaces, complete all as specified and directed. |
| 10 | Excavating in trenches n exc 1.5m wide and n exc 1.5m depth for foundation etc or for shafts, well, cesspits, manholes, pier holes, cable tranch, pole, drain etc n exc 10 sq m on plan and n exc 1.5m depth and getting out in soft/loose soil complete all as specified and directed. |
| 11 | All as per item No 10 above but exc. 1.5m but n exc 3m depth |
| 12 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed. |
| 13 | Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point, complete all as specified and directed. |
| 14 | Hard core of broken stone or boulders of guage n. exc 63mm but exc 100mm, deposited, spread and levelled in layers n. exc 15 cm thick, watered and rolled/rammed to a true surface,complete all as specified and directed. |
| 15 | M&L 25mm thick Sand filling under floors or paving including levelling, watering and consolidationand all as specified complete all as specified and directed. |
| 16 | 100mm thick PCC 1:4:8 Type D-2 (40 mm graded stone aggregate) as insub-base of floors, sub-bases, floors, pavings etc., complete all as specified and directed. |
| 17 | PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps;kerb stoneseismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork, complete all as specified and directed. |
| 18 | M&L for PCC 1:4:8 type D-2 using (40mm graded crushedstone aggregate) in foundation, filling and mass concrete complete all as specified and directed. |
| 19 | M&L for cemnent concrete 1:2:4 type B-2 using (40mm graded crushedstone aggregate) in foundation, filling and mass concrete, surface bed to drain complete all as specified and directed. |
| 20 | PCC1:2:4 type B-0 (using 12.5mm graded crushedstone aggregate) as in benching etc complete all as specified and directed |
| 21 | M&L forPCC 1:3:6 Type C1 (using 20 mm graded crushedstone aggregate) as in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, benching to manholes, kneelers, apex stones,bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed |
| 22 | M&L for Brick work with fly ash bricks (Old Size bricks), sub class\"B\" bricksstraight or curved on plan exc 6 mtr mean radius built in CM 1:4 complete all as specified & directed. |
| 23 | M&L for 15mm thick cement plastering on concrete surface in CM 1:4 surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 24 | Extra for forming fair finished drain or channel 60cm inner girth in cement concrete, using extracement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed |
| 25 | S&F Mild Steel posts and struts in fencing including cutting top to shape as directed, drilling holes, notiching for wire etc, flat iron 40x6 mm fillet (for securing wire mash etc) including all necessary drilling bolting or revetting etc including tarring to embaded steel work and similar work conforming to Fe 410-0 or Fe-310-0 complete all as specified and directed. |
| 26 | S&F framed work such grill of angle iron or other section with guset plate door grills, framed, drain cover etc, conforming to Fe 410-0 or Fe-310-0 complete all as specified and directed. |
| 27 | M&L for Providing, precast cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates), as in cover slabs (for septic tanks, manholes and the like) and similar articles including necessary moulds/fromwork etc, set and jointed in cement mortar (1:6) complete all as specified and directed. |
| 28 | M&L for PCC type C-1, 1:3:6 (using 20mm graded crushedstone aggregate) as in plinth protection and paving 75mm thick laid in slope finished even and fair including making joints not more than 2.5 m (or as directed) and at corner, filled with bitumen 85/25 and sand in ratio 1:2 by weight complete all as specified and directed. |
| 29 | M&L for rendering 5mm thick in CM 1:3 on concrete surface of ceiling, chajja etc, finishing the surfaces even and smooth without using extra cementcomplete all as specified and as directed. |
| 30 | M&L for Rendering 10mm thick on fair faces of brick work/ concrete sruface in cement mortar (1:6), finished even and smooth without using extra cement complete all as specified and directed. |
| 31 | M&L for Rendering 15mm thick on fair faces of brick work, concrete sruface in cement mortar (1:4), finished even and smooth without using extra cement complete all as specified and directed.Note : (WPC will be measured and paid seperately) |
| 32 | M&L for rendering or plastering 10 mm thick in CM 1:3 in fascia / edging / ceiling of Chajjas,roof projections, drainge etc, making the edges in line, in true shape and finishing the surface without using extra cement complete all as specified and directed. |
| 33 | Preparation of new plastered surfaces of walls and applying 2mm thick wall care putty, making the surface smooth & applying two coats of oil emulsion paint over a coat of priming paint , complete all as specified and directed. |
| 34 | M&L for preparation of new plastered surface of external wall and chajjas,making surface smooth using sand paper, priming the surface with alkali resistance primer paintfor external surface, applying two coats of cement base paint including curing complete all as specified & directed. |
| 35 | M&L for preparation of new plastered surface of walls and applying three coats of white wash complete all as specified and directed. |
| 36 | M&L for preparation of new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primercomplete all as specified and as directed. |
| 37 | M&L for two coats of white wash on surface of wall including preparation of new plastered surface complete all as specified and as directed. |
| 38 | M&L for three coats of white wash on surface of ceiling including preparation of new plastered surface complete all as specified and as directed. |
| 39 | M&L for three coats of white wash on surface of wall including preparation of new plastered surface complete all as specified and as directed. |
| 40 | M&L for three coats of white wash on surface of wall including preparation of old plastered surface complete all as specified and as directed. |
| 41 | Supply only 3.15mm dia,galvanized steel wire chain link fencing 50mm x 50mm mesh, including binding wire / line wire etc complete all as specified and as directed. |
| 42 | Fixing only 3.15mm dia,galvanized steel wire chain link fencing 50mm x 50mm mesh, foxed to RCC fencing post with bolts etc including fixing of binding wire/line wire, mild steel round bar etc complete all as specified and directed. |
| 43 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm but n exc 10cm long (dia of shank 11-15mm) complete all as specified and directed. |
| 44 | S&F only 10 mm dia mild steel round bars as in stiffener to chain link fencing including necessary cutting bending etc. conforming to Grade-I, IS 432-2000 (Part-I) complete all as specified and as directed. |
| 45 | S&F Mild steelTMT bars 08mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 46 | S&F Mild steelTMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 47 | M&L for rolled mild steel as in roof trusses (framed), trussed, purlins, rafters, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, hollow section square/rectangular) or flat sections including distance pieces, cleats, MS plate, welding, bolts etc, Fe 410-W (Gde- E-250) quality-A including one shop coat of zinc chromate primer paint beofre fixing in position complete all as specified & directed. |
| 48 | S&F Pre-painted galvalume aluminum zinc coating( zinc coating 275) GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to walls, fixed with self tapping screws complete all as specified and directed. |
| 49 | All as per item No 48 but 0.50mm thick plain pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet. |
| 50 | M&L for Reinforced cement concrete (nominal mix) in 1:2:4 type B-1 using 20mm graded crushedstone aggregate in foundation, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 51 | M&L for Reinforced cement concrete (nominal mix) in 1:2:4 type B-1 using 20mm graded crushedstone aggregate in Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 52 | M&L for Reinforced cement concrete in chajjah, slab supported on walls, beams, columns complete all as specified and directed. |
| 53 | Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, includingflat rough finished surafaces of concrete complete all as specified and directed. |
| 54 | Use and waste of formwork to sides and soffits of floor and roof beams, beams haunching, girders, bressummers, lintels and cantilever, shelves including supports over hangs etc rough finished surfaces of concrete (flat) complete all as specified and directed. |
| 55 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar works,flat, rough finished surafaces of concrete; not exceeding 200mm thick (horizontal or sloping) complete all as specified and directed |
| 56 | Use and waste of formwork to chullah hoods, chajjas, troughs & similar items including edges rough finished surfaces of concrete (flat) complete all as specified and directed. |
| 57 | Use and waste of formwork to sides of pillars, posts, struts, piers, columns, and stanchions, square, rectangular or polygonal in shape, including flat rough finished surafaces of concrete complete all as specified and directed. |
| 58 | Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floors & roofs n exc 20cm wide & sides of RCC/PCC bands in walls, horizontal or sloping, & similar work exc 10cm but exc 20cm wide, rough finished surfaces of concrete complete all as specified and directed |
| 59 | S&F 35mm thick factory made 2nd class hard woodglazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (divided into squares with plain chamfered or rounded, mitred and rebated without sash bars any umbers), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads and fitted to chowkats for securing glass/gauge. Size of stiles rails and other parts as per clause 8.24 (a) of SSR Part-Icomplete all as specified & directed. |
| 60 | M&Ltwo coat synthetic enamel paint over a coat of red oxide primer on old steel or steel based surfaces of any description over 10 cm width or girth including preparation of surfaces, complete all as specified and as directed. |
| 61 | Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately). |
| 62 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 65x100 mm (single rebate) comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/ moisture proof and fire retardant, fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length completeall as specified and directed.Note: (i) M.S. hold fast/ lugs or SS dash fasteners shall be paid separately.(ii) For WPC solid door/window frames minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. (iii) Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified and directed. |
| 63 | S&F 35mm thick factory made plain framed panelled shutters of2nd class hard wood, two panels with lock rail and panel of 9mm thick BWP commercial ply.The size of rail and stile as per IS-1003 (Part-I), Kiln seasoned and chemically pressure treated factory made shutters wood is to be incorpated complete all as specified and directed. |
| 64 | S&F pressed steel frames for doors/windows of size size 125x60 mm (1.25mm thick MS sheet)with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc,painted with a coat of primer and two coats of synthetic enamel paints complete all as specified and directed. |
| 65 | S&F Box type Steel windows and ventilators comprised of tubular frameand shutters made out of 1.25mm thick MS steel tube factory made with double side shutters wire gauged shutter & glass glazed shutter with side hung shutters with steel handle and steel peg staydovetailedor welded including 2 Nos tower bolts 150mm long for each leaf and 10mm square bar grills at spacing as shown on drg welded to FI frame work, including other fittings, hinges, handles, tarred hold fasts, PCC blocks (1:2:4 type 12.50mm graded crushed stone aggregate) including 3mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/galzing pins i squres n.exc 0.5 sqm in each plane, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperature 1.4mm and fixed with stainless steel wire staplesincluding two coats of synthetic enamel paint over a shop coat of red oxide primer etc. all as shown on drg No CEPZ /TD-354/09 sheet 1/3 to 3/3 complete all as specified and directed. |
| 66 | Hacking out old broken glass ( any thickness , size, quality, or description) from metal frame glazed with putty or fixed with beads/ clips, rubbish off the premises complete all as specified and directed. |
| 67 | S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture1.40 mm fixed with tinned tacks, or galvanized wire staples complete all as specified & directed. |
| 68 | S&F in repair Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture1.40 mm fixed with tinned tacks, or stainless steel wire staples complete all as specified & directed. |
| 69 | S&F 3mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exc 0.50 Sqm in each pane complete all as specified and directed. |
| 70 | S&F 3mm thick Figured glass , pin head type & glazing with oil putty o in squares not exc 0.50 Sqm in each pane complete all as specified and directed. |
| 71 | M & L preparation of old wood or wood based surfaces of any descriptionover 10 cm width or girth and applying two coats of synthetic enamelpaint over a coat of pink primer complete all as specified & directed. |
| 72 | S&F for 300 mm long aluminium alloy, sliding door bolt withhasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts complete all as specified and directed |
| 73 | S&F15mm bore mild steel tubes medium grade galvanized ISI marked with all fittings, short pieces and fixed to walls, floor, ceiling etc complete all as specified and directed. |
| 74 | S&F20mm bore tubes medium grade galvanized ISI marked with all fittings, short pieces and fixed to walls, floor, ceiling etc complete all as specified and directed. |
| 75 | S&F 20mm bore dia gun metal globe or gate valves (as per sample) cast copper alloy chromium plated fancy type,ISI marked with crutch or butter fly handleswith iron wheel head, screwed both ends for iron pipe and fixedcomplete all as specified and directed |
| 76 | S&F in repairs 20mm bore dia gun metal globe or gate valves (as per sample) cast copper alloy chromium plated fancy type,ISI marked with crutch or butter fly handleswith iron wheel head, screwed both ends for iron pipe and fixedcomplete all as specified and directed |
| 77 | S&F Rotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top) three layers, Capacity 1000 litres, ISI Marked including all accessories, hoisted and fixed in position all as specified in SSR Part-Icomplete including 20mm dia ball brass valve high pressure with polythene floatcomplete all as specified and directed.. |
| 78 | Rotational moulded polyethlene water storage tanks of capacity exc 500 litres three layers(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete including 20mm dia ball brass valve high pressure with polythene float and dismantling of existing PVC/RCC tank of any capacity complete all as specified & directed. |
| 79 | S&F 100mm bore cast iron soil, waste and vent pipes, sand cast, in any length with or without ears fixed to walls with clamps and cement jointcomplete all as specified and directed. |
| 80 | S&F 75mm bore cast iron soil, waste and vent pipes, sand cast, in any length with or without ears fixed to walls with clamps and cement jointcomplete all as specified and directed. |
| 81 | S&F 75mm bore cast iron soil, waste and vent pipes, sand cast, in any length with or without ears laid in floor with cement jointcomplete all as specified and directed. |
| 82 | S&F 100 mm boreCast iron bends (any radius) diminishing pieces or tapers (larger bore measured) complete all as specified and directed. |
| 83 | S&F 100 mm boreCast iron bends (any radius) diminishing pieces or tapers (larger bore measured) with ovel asses door complete all as specified and directed. |
| 84 | S&F 75mm boreCast iron bends (any radius) diminishing pieces or tapers (larger bore measured) complete all as specified and directed. |
| 85 | S&F 75 mm boreCast iron bends (any radius) diminishing pieces or tapers (larger bore measured) with ovel asses door complete all as specified and directed. |
| 86 | S&F110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. |
| 87 | 110mm bore dia PVC (SWR) bends,any radius (larger bore measured), complete all as specified and directed. |
| 88 | S&F in repair Cast iron floor trap 75mm with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1 with CP grating with ot without hole for waste pipe complete all as specified and directed. |
| 89 | S&F in repair Cast iron cowl of 50mm bore complete all as specified and directed. |
| 90 | M&L for glazed ceramic coloured tiles in vertical surface 300x450x7mm thick set and jointedin neat cement slurry and pointed in white or coloured cement to match over 10mm thick screed bed or bedding layer of mortar in CM 1:4complete all as specified and directed. |
| 91 | Non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqmbut not exceeding 0.18 sqmin floors etc set and jointed(joint free) in neat cement slurry and pointed in coloured cementover 15mm thick screed bed or bedding layer of mortar in CM 1:4 including taking down of existing surfaces complete all as specified and directed. |
| 92 | Glazed ceramic coloured tiles 450mm x 350mm x 7mm thick as in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry,pointed in white or coloured cement to matchover and including 10mm thick renderingin cement mortar 1:4 to receive tiles complete all as specified and directed. |
| 93 | S&F Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm wood grain printedPVC sheet used instead f plain colour PVC sheet & edges will be painted to matc wit printed sheet reinforced with MS square tube, supplying and fixing in opening as per specification and drawing |
| 94 | S&F Factory Made Solid PVC Moulded door Shutter With wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick prelam Moulded PVC Sheet on the front face & 2mm plain colour prelaminated PVC sheet on back face complete all as specified and directed. |
| 95 | S&F15mm bore mild steel tubes medium grade galvanized ISI marked with all fittings, short pieces and fixed to walls, floor, ceiling etc complete all as specified and directed. |
| 96 | Refixing of old steel tubing 15 mm medium grade galvanized ISI marked with new all fittings short pieces and fixed complete to walls, floor etc complete all as specified and directed. |
| 97 | M&L for cutting chases, pinning in brick work,making good to facing where required, pointing in CM 1:3, cutting n.exc. 10cm in girth complete all as specified and directed. |
| 98 | S&F20mm bore tubes medium grade galvanized ISI marked with all fittings, short pieces and fixed to walls, floor, ceiling, in trenching etc complete all as specified and directed. |
| 99 | Refixing of old steel tubing 20 mm medium grade galvanized ISI marked with new all fittings short pieces and fixed complete to walls, floor etc complete all as specified and directed. |
| 100 | S&F 100 mm long Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed. |
| 101 | S&F aluminiumanodized barrel tower bolts 150 mm of extruded section (as per sample) fixed complete all as specified and directed. |
| 102 | S&F aluminiumanodized barrel tower bolts 200 mm of extruded section (as per sample) fixed complete all as specified and directed. |
| 103 | S&F 150 mm size aluminium alloy handles, febricated type extruded section(as per sample), complete all as specified and directed. |
| 104 | S&F 300mm, MS rat tail door springs for door closer complete all as specified and directed. |
| 105 | S&F 15mm bore dia angle valve / stop valve cast copper alloy capston head chromium plated (as per sample), fancy type ISI marked with crutch or butter fly handles screwed down, screwed for iron pipe complete all as specified and directed. |
| 106 | S&F Stop valve concealed cast copper alloy (ISI Markd) fancy type, chromium plated with long shank and cup (concealed type) screwed down high pressure with crutch lever handle screwed both ends for iron pipe 15mm bore dia fixed in repair, complete all as specified and directed. |
| 107 | S&F 15mm bore dia Bib taps long body, cast copper alloy, chromium plated fancy typeISI marked (as per sample) with crutch or butter fly handles, screwed down, screwed for iron pipe complete all as specified and directed. |
| 108 | S&F in repair 15mm bore dia Bib taps long body, cast copper alloy, chromium plated fancy typeISI marked (as per sample) with crutch or butter fly handles, screwed down, screwed for iron pipe complete all as specified and directed. |
| 109 | S&F towel rail, brass, CP 600 mm long 20mm dia pipe of 1mm thick complete all as specified and directed. |
| 110 | S&Fin repairs towel rail, brass, CP 600 mm long 20mm dia pipe of 1mm thick complete all as specified and directed. |
| 111 | 125mm size brass chromium plated shower rose with or without swivel joints, any size including fixing to steel pipe of 15mm diaor union, complete all as specified and as directed. |
| 112 | S&F in repirsbrass chromium plated shower rose with or without swivel joints, any size including fixing to steel pipe of 15mm diaor union, complete all as specified and as directed. |
| 113 | S&F in repair glass shelf assembly consisting of 5.5mm thick sheet glass 12cm wide (as per sample) with chromium plated brackets double guard and railing 60cm long, complete all as specified and directed. |
| 114 | 600 mm x 450 mm bevelled edge mirror of selected quality glass mounted on 6 mm thick AC building board or BWP commercial plywood and fixed to wooden plugs/PVC rawl plug with chromium plated brass screws and cup washers, complete all as specified and directed. |
| 115 | S&F 15mm bore pillar cock fancy swan neck type, screwed down high pressure crutch lever handle with or without letters hot or cold with long screwed shank and fly nuts screwed for iron pipe ISI marked fixed in repairs complete all as specified & directed. |
| 116 | S&F Vitreous China squatting pan of orissa pattern, size 580x440mm white with CI ‘P’ or ‘S’ trap, front or back inlet and foot rests, any pattern (including fixingofflush pipe) including provision of cement concrete bedding complete all as specified and as directed. |
| 117 | S&F in repairsVitreous China squatting pan of orissa pattern, size 580x440mm white with CI ‘P’ or ‘S’ trap, front or back inlet and foot rests, any pattern (including fixingofflush pipe) including provision of cement concrete bedding in repair complete all as specified and as directed. |
| 118 | S&F in repair PVC flushing cistern 10 ltr capacity incl PVC connection inlet and and outletconnections,brackets, PVC flush pipe with bend 32 mm dia of suitable length including making necessary connections to water supply pipe line and jointing to WC all as specified and directed. |
| 119 | PVC connection 15mm size with PTMT nuts of length 450mm,complete all as specified and directed. |
| 120 | S&Fin repairs counter type Vitreous china wash hand basin, white flat back, size 550 x 400 mm (as per sample), including brackets, CP waste coupling and cutting for and pinning in ends of brackets or errecting standincluding 32 mm diawaste pipe complete all as specified and directed. |
| 121 | S&F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe including Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified & directed. |
| 122 | PCC 1:5:10 type E-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete (sunken floors etc) complete all as specified. |
| 123 | M&L for bitumen blown any grade, applied hot, two coats, to concrete/plastered surfaces @ 1.5 Kg per sqm per coat and applying polythene film black, 50 micron complete for sunken floor slab and embedded in side wall / covered fillet complete all as specified and directed. |
| 124 | M&L for bituminous road cutting to a width of 45cm and depth of 50cm for laying of sewage pipe, culverts etc and making good with PCC (1:3:6) type CI (using 20mm grade stone aggregate) complete all as specified and as directed. |
| 125 | M&L for 200 mm bore reinforced cement concrete pipes, class NP2, laid and jointed complete with collars including demolition and breaking up existing RCC/SWG/AC/PVC drain pipes and removal of rubbish complete all as specified and directed. |
| 126 | M&L for Concrete bed todrain pipes 200 boreincluding packing under, and haunching against the sides& surrounding of pipes after they are laid and tested; in cement conctrete type C-2, 1:3:6, using 40 mm graded crushedstone aggregate complete all as specified & directed. |
| 127 | M&L for Dismantling existing undulated interlocking tile (paver) of any descripion/thicknessincluding sand cushion, providing 75mm thick (avg thickness) PCC sub base 1:4:8 type D2 using 20mm graded stone aggregate (to maintain with adjacent sub base top level), laying of old interlocking tiles(paver) using old sand as sand cushion as per site condition complete all as specified and directed. |
| 128 | M&L cement plaster 10mm thick CM (1:4) with WPC on roof suraface and finished even and smooth w/o using extra cement complete all as spd (WPC shall be masured and paid seperately). |
| 129 | 80mm thick factory made machine pressed precast concrete, coloured interlocking paver blockwith cement and coloured pigment (topping thickness not less than 5mm thick with white cement and non-fadable epoxy coated colour pigment), any shape,size and design as approved by Engr-in charge confirming to IS 15658-2006, M-40 grade, complete all as specified and directed. |
| 130 | Machine cut kota stone slab flooring of size not less than 53x53cm and 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with mirror cut including 50 mm thick screed bed in cement mortar 1:4 complete all as specified and directed. |
| 131 | M&L for preparation of surface and apply first of coat fiber reinforced elastomeric liquid water proofing membrane formulated with PU hybrid ploymers and reinforcing acrylic fiber with sun reflective index (SRI) of 100-110 having minium elongation of 350% tensile strenght of 2.9 Mpa and shall have cracks briding ability upto 2.5mm and shall resist 10 bars of hydrostatic presssure & reduce surface temperature upt to 10 degree celsius with 33% dilution of priming coat. Laying of fiber mesh of 0.3mm thickness weave in leno pattern having 45 gsm/sqm and pasting it properly with overlap of 50mm and allow it to dry. Apply second of undiluted coat @ 0.45 ltr/sqm. Apply third and final coat undiluted @ 0.45 kre/sqm complete appliction to be done by the manufacturer or authorised applicator complete all a specified and directed. |
| 132 | Note for item No 131 :-(a) Cleaning of dust, removal for all loose existing bituminous material manually with heat torch gun to get smooth plain finished surface, removing of vegetation/plantaion with no loose material on surface.(b) Conduct ponding test after 7 days, continnue curing of 14 days.(c) All Shifting/ removing of any wire/cable/AC unit/Water tank of any capacity or other any object as per site requirement an re-fixing the same, if needed shall deemed to be included in the quoted rates by the contractor. (d) Removal of any loose/packed items such as mud phuska, terrace tiles, cement screed bed shall be removed and surface shall be made free from depressions before applying treatment to the roof. Quoted rates shall deemed to be includedthis fact into account and no extra payment shall be made on this account. (e) Contractor shall verify availability of the materials in full qty from market before quoting the rates as no extension of time on this ground shall be granted.(f) All the sample/ make for water proofing material mentioned in item shall be got approved from the GE before procuring bulk quantity of material. |
| 133 | Supply onlyIntegral water proofing admixture liquid |
| 134 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including unscrewing from board fitting and fixturesuch as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody for reuse if serviceable or for taking credit and making good disturbed surfaces of walls, floors, etc with cement mortar and finishes to match existing surface complete all as specified and directed. |
| 135 | Point wiringusing 3x1.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade (Phase, neutral and earth wire) with proper colour coding drawn through and incl PVC rigid concealed conduit medium grade (ISI Marked) of dia not less than 20mm and 1.5mm thick and connected to common earth dolly with and including 1.6mm thick GI/MS modular sunken box of required size with support frame (inner/outer) for mounting modular switch , sockets etc including cutting chases grooves for concealed wiring for light/fan/bell point controlled by one switch and making good (in CM 1:4) the surface as per existing complete all as specified and directed. |
| 136 | Modular one way switch 10 Amp, 1 module, complete all as specified and directed. |
| 137 | M&L for point wiringusing 3x1.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade (Phase, neutral and earth wire) with proper colour coding drawn through and incl PVC rigid concealed conduit medium grade (ISI Marked) of dia not less than 20mm and 1.5mm thick and connected to common earth dolly with and including 1.2mm thick GI/MS pressed steel sunken box of pressed steel sunken boxes of adequate size,3mm thick plastic laminated sheet cover fixed with brass screws including cutting chases grooves for concealed wiring for light/fan/bell point controlled by one switch wiring for light/fan/bell point controlled by one switch and making good (in CM 1:4) the surface as per existing complete all as specified and directed. Note:- 1) Conduit shall be fixed on surface/ceiling with necessay saddles where concealing of conduit is not feasible.2) Rate of supplying and fixing modular GI/MS pressed sunken box with support frame deemed to be included in the quoted rates. |
| 138 | All as per Ser item No 136 but for one5/6 Amp socket outlet point on same board controlled by one switch. |
| 139 | All as per Ser item No 136 but for one5/6 Amp socket outlet points on independentboard controlled by one switch. |
| 140 | All as per Srl item No 136 here-in-before for one 15/16 amp socket point with 3x2.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor. |
| 141 | S&F switch piano flush button single pole one way 5/6 Amp 240 volts complete all as specified and as directed. |
| 142 | S&F socket outlet 2 in 1, 3 pin, 5/6 Amps, flush type with shutters, 240 volts complete all as specified and as directed. |
| 143 | S&F socket outlet 2 in 1, 6 pin, 6/16 Amp flush type, 240 volts complete all as specified and as directed. |
| 144 | S&F switch 15/16 Amps, flush type, 240 volts complete all as specified and as directed. |
| 145 | S&F ceiling rose PVC/polycarbonate, insulated body surface Bakelite 65mm dia three terminals. |
| 146 | S&FLamp holder jumbo modular type, PVC/Polycarbonate type with back plate suitable for batten fitting including 15 W LED lamp complete all as specified. |
| 147 | S&Fmodular switch one way 10 Amp one module, front operated complete all as specified and directed. |
| 148 | S & F for sub Main Wiring with two single core FRLS PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x4 Sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 4 Sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in and including suitable size concealed rigid medium grade PVC conduit not less than 25mm dia 1.5mm thickwith all accessories incl cutting chases on wall andmaking good to the disturbed surface of wall/floor with cement mortar 1:4 and finishes to match existing surface complete all as specified and directed. |
| 149 | S&F 20W surface / wall mounted box type batten LED fitting having polycarbonate housing and diffuser and integrated electronic driver with system luminous efficacy ≥ 100 lumens/Watt operating voltage 140V-240V complete with all accessories internally prewired and including connecting up with suitable size flexible copper conductor cable from ceiling rose to connector of LED fitting complete all as specified and directed. |
| 150 | All as per ser item No 148 but for 10 W LED batten fitting 2 feet long. |
| 151 | S&Fsurface mounted, bulk head LED luminaire 10 W with and integrated electronic driver with system luminous efficacy ≥ 100 lumens/Watt operating voltage 140V-240V, IP 65 protectioncomplete with all accessories internally prewired and including connecting up with suitable size flexible copper conductor cable from ceiling rose to connector of LED fitting complete all as specified and directed. |
| 152 | Disconneting & taking down exhaust fan any type/ cap refixing to the same/other location after replacing rubber reel, fixing bolts and nuts with lock pins, connectors complete all as specified and directed. |
| 153 | Disconneting & taking down geyser any type/capacity complete,refixing to the same/other location with all connected accessories afer cleaning replacing anchor bolts complete all as specified and directed. |
| 154 | Supply and fixing of 5 star rated BLDC (Brush less direct current motor) ceiling fan 230 volts,single phase of 1200mm sweep duble ball bearing tyoe with minimum air delivery 210 CFM & service value shall not be less than 6.0 B.E.E including blade, down rod, bldc refulator and canopy cover etc, including connecting with 3 core flexible copper conductor cable of size 0.50 Sqmm and including writing of MES Number with synthetic enamel paintcomplete all as specified and directed. |
| 155 | Supply and fix electric water heater, storage type ABS body type with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc including steel braided flexible connection for pipe of size 15mm bore with GI hexagonal adopters/Nuts on both sides for inlet ( cold water supply) and out let (hot water supply), provision of wall mountingarrangement , mounted on wall with suitable sige of anchor bolts, making connection including testing complete all as specified and directed. |
| 156 | Supply and fixing of exhasut fan 250 mm sweep , double bearing copper wounded plastic body, AC single phase 230/240 Volts having 1200 +/- 50RPM and power consumption not more than 50 watt including box type square shaped metallic louvers made out of powder coated CRCA sheet of thickness not less than 01 mm and fixed with grouting nut & bolts and making the suitable hole of suitable size by breaking the existing wall and making good the disturbed surface by plastering and matching with existing specifications with suitable finishes as per site requirement complete all as specified and as directed. |
| 157 | Supply and fixing of exhasut fan 230 mm sweep , double bearing copper wounded plastic body, AC single phase 230/240 Volts having 1400 +/- 50RPM and power consumption not more than 45 watt with minimum air delivery 700 CMH including box type square shaped metallic louvers made out of powder coated CRCA sheet of thickness not less than 01 mm and fixed with grouting nut & bolts and making the suitable hole of suitable size by breaking the existing wall and making good the disturbed surface by plastering and matching with existing specifications with suitable finishes as per site requirement complete all as specified and as directed. |
| 158 | MCB DB, SPN, 8 way sheet metal enclosures double door 230 V AC, 50 Hz AC with IP 43 and IK 09 rating having fully insulated copper busbar, neutral bar, earth bar and cable ties for cable management including polyuthrene gasket complete complete in all respect flushed in wallincluding cutting chases on wall for taking out old unsv DB and fixing of new DB and making good disturbed surface of wall with cement mortar 1:4 and finishes to match exisiting surface, complete all as specified and directed. |
| 159 | MCB DB, SPN, 4 way sheet metal enclosures double door 230 V AC, 50 Hz AC with IP 43 and IK 09 rating having fully insulated copper busbar, neutral bar, earth bar and cable ties for cable management including polyuthrene gasket complete complete in all respect flushed in wallincluding cutting chases on wall for taking out old unsv DB and fixing of new DB and making good disturbed surface of wall with cement mortar 1:4 and finishes to match exisiting surface, complete all as specified and directed. |
| 160 | S&F MCB SP 240V, 50Hz of rating6 to 32 Amp, \"B\" curve using suitable size copper thimbles complete all as specified and directed. |
| 161 | All as per Ser item No 159 but for size 32 Amps MCB SPN. |
| 162 | All as per Ser item No 159 but for size 40-63 Amps MCB SPN. |
| 163 | Cutting old GI pipes 25/40/50/100mm bore dia only and reducing to required length, before laying in positon for insertion of new tees, branches etc for repair works complete all as specified and directed. |
| 164 | Supply, laying and testing XLPE insulated, screened, PVC beded galvanized steel strip or wire armoured, electric cable heavy duty 1100 volts grade wirh stranded aluminium conductor of size 16 Sqmm 4 core including making good all distributed wall surfaces/ flooring/tilling/road to match with existing specifications complete all as specified and directed. |
| 165 | Supply, laying and testing XLPE insulated, screened, PVC beded galvanized steel strip or wire armoured, electric cable heavy duty 1100 volts grade wirh stranded aluminium conductor of size 10 Sqmm 2 core including making good all distributed wall surfaces/ flooring/tilling/road to match with existing specifications complete all as specified and directed. |
| 166 | S&F flood light fitting LED 100 Watt , 240 volts, IP65 Energy saving & environmental friendly long life Versatile pressure die-cast alumimium housing with high power LEDs PC lens with toughned glass and electronic driver fixed on pole/ wall along with clamps, nuts , bolts and washers as directed including making electric connectioncomplete all as specified and directed. |
| 167 | S&F flood light fitting LED 90 Watt , 240 volts, IP65 Energy saving & environmental friendly long life Versatile pressure die-cast alumimium housing with high power LEDs PC lens with toughned glass and electronic driver fixed on pole/ wall along with clamps, nuts , bolts and washers as directed including making electric connectioncomplete all as specified and directed. |
| 168 | M&L for sand filling in trenches as cushion to under ground cables 8 cm thick before laying the cable and 15 cm thick when cables are laid and tested complete all as specified and directed. Note: Only punned thickness i.e 18cm shall be measured and paid. |
| 169 | M&L for Sub class ‘B’ bricks (fly ash bricks) old size laid dry, flat over the cable abutting each other, length of cable equal to width of brick complete all as specified and directed. |
| 170 | M&L for PCC 1:4:8 type D-2 (using 40mm graded crushedstone aggregate) as in foundation, filling and mass concrete including necessary form work complete all as specified and directed. |
| 171 | M&L for plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregrate for pole coping complete all as specified and directed. |
| 172 | 40mm dia GI tubing, light grade with all fitting laid in trenches or fixed on wall/under road/ floor or pole by means of GI/MS clamps, nut bolts and washers complete all as specified and directed. |
| 173 | S&F LED wall security lights of 35 Watt, 230 voltshaving pressure die cast aluminium housing with system lumens efficacy≥100 lumen/W,IP65 protection, IK07 rating,inbuilt electronic driver withPF>0.95 incl GI bracket of suitable dia bend to shape and fixed to wall by means of clamps or nuts bolts and connecting up with three core twisted flexible copper conductor cable complete all as specified and directed. |
| 174 | S&F automatic timer switch astro type of ON/Off street lights based on lux level of natural light with current rating of 20 Amps 2 Pole 230 V AC, 50 Hz max and sensor based timer having over voltage and low voltage trip with auto reset facility complete with MCB 20 Amp, single pole, contactor of rating 20 Amp suitable for5KW to 4KW load fixed in suitable size of SMC/Pollycarbonate box IP-65 etc, making all electric connection complete all all as specified and directed. |
| 175 | Supply, erection and installation of steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long)duly painted with two coats of black bituminous paint through out, internally and externally up to planning depth, and painting remaining portion of pole with two coats of aluminium paint to the entire exposed surfaces over one coat of red oxide primer, making/painting three Nos circular strips each of 30 cm wide with one yellow and 02 Nos black colour strip with synthetic enamel paint,marking pole number with black paint complete all as specified and directed. Note : Excavation, earth work, PCC work shall be measured and paid for separately. |
| 176 | Cross arms, bracings, supports, clamps and back plates fabricated form structural steel sections includiing nuts, bolts, washers, welding, bending, hot or cold drilling holes for bolts in any size or shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed. |
| 177 | M&L for Earthing complete with galvanised cast iron earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit alongwith angel iron 40x40x3mm frame and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil remaing surplus excavated material all as required at site and specified in EP No 3 of SSR part I or directedand testing on completion. |