| 1 | SCHEDULE \"A\" SECTION-I(BUILDINGS/STRUCTURE WORKS) |
| 2 | Construction of block of ‘GUARD ROOM WITH TOILET (S/S)’ complete all as specified and shown on drawings. |
| 3 | SCHEDULE ‘A’ SECTION-II (PART-I) (INTERNAL WATER SUPPLY WORKS) |
| 4 | Lump sum price worked out by the Contractor for “Internal Water Supply Works” as listed in Schedule ‘A’ Section-II (Part-I). |
| 5 | SCHEDULE ‘A’ SECTION-II (PART-II) (INTERNAL WATER SUPPLY WORKS) |
| 6 | Supply & fixing 15mm bore Angle stop valve, fancy type with long shank and cup of cast copper alloy chromium plated, screwed down, high pressure with capstan heads, screwed both ends for iron pipe or for union complete all as specified & as directed. |
| 7 | S&F wall mixer,telephonic type, brass, chromium plated,fancy type, with capstan head handles with lettered \"hot\" and \"cold\", screwed down high pressure, including CP brass wall flanges and necessary extension nipples screwed for 15mm bore pipe connection,complete all as specified as directed.Make : Cat Part No. ‘G4916A1’ of ‘Parryware’ / Cat Part No. ‘F2002401’ of ‘Cera’ / Cat Part No. ‘CQT-23281UPR’ of ‘Jaquar’ / Cat Part No. ‘9275’ of ‘Prayag’ or equivalent in makes mentioned in Appendix ‘B’ here-in-after. |
| 8 | S&F Centre hole mixer for mixing hot & cold water for wash hand basin, cast copper alloy, with dual capstan heads, chromium plated, screwed down high pressure, with lettered \"Hot\" & \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe suitable for 15mm bore, complete all as specified as directed.Make : Cat Part No. ‘G4914A1’ of ‘Parryware’ / Cat Part No. ‘F2002461’ of ‘Cera’ / Cat Part No. ‘CQT-23167B’ of ‘Jaquar’ / Cat Part No. ‘9250’ of ‘Prayag’ or equivalent in makes mentioned in Appendix ‘B’ here-in-after. |
| 9 | Supply & fixing stainless steel Peg Set of Six of standard size (not less than 300mm long) fixed to wall with two rawl plugs and chromium plated brass screws complete all as specified & as directed.Make :- Cat Part No BEA-30 of make – Prayag or equivalent in makes mentioned in Appendix \"B\" here-in-after. |
| 10 | S&F 20mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, complete all as specified & directed. |
| 11 | Supply & fixing spray jet, brass chromium plated with and including 1.5 metre long PVC flexible reinforced pipe for EWC for 15mm bore pipe complete all as specified & as directed. |
| 12 | Subtotal {Total of Schedule \"A\" Section-II (Part-II)} |
| 13 | SCHEDULE ‘A’ SECTION-III (PART-I) (INTERNAL ELECTRIFICATION WORKS) |
| 14 | Lump sum price worked out by the Contractor for “Internal Electrification Works” as listed in Schedule ‘A’ Section-III (Part-I). |
| 15 | SCHEDULE ‘A’ SECTION-III (PART-II) (INTERNAL ELECTRIFICATION WORKS) |
| 16 | Material & labour for point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium grade, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etcall as per IS, terminated in & including new sunk type pressed steel terminal boxes concealed in wall for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover, complete all as specified and as directed.Note : (i) Cost of cutting/leaving forming chases for conduits, sinking for boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item.(ii) The quoted rates of this item shall be deemed for include for modular metal flush boxes of requisite module and modular cover plate with frame of requisite module of colour as approved by GE. |
| 17 | All as per serial item No. 16.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches. |
| 18 | All as per serial item No. 16.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board. |
| 19 | All as per serial item No. 16.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.5 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 2.5 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour. |
| 20 | All as per serial item No. 16.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour. |
| 21 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 5 watt, 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & as directed. |
| 22 | S&F LED tube light fitting, 1x20 Watt, 230 Volts, basic all purpose surface and wall mounted LED batten type with driver & polycarbonate housing including tube rod and all accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ ceiling rose, complete all as specified and as directed.Make : Philips, Cat Part No. LED 20S PSU CW GR S2/ Crompton Greaves, Cat Part No. LDDR20-CDL Dazzle Ray/ Bajaj, Cat Part No. BCLAB 20W or equivalent make here-in-after in appendix \"B\" |
| 23 | Supply and fixing LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder and connecting up with three core flexible copper conductor cable of suitable size complete all as specified & as directed. |
| 24 | Supply, installation, commissioning & testing Light Emitting Diode (LED) based street/security light fitting, 35 Watt with & including LED lamp, housing made up of LM6 pressure die cast aluminium alloy with effective thermal management, sturdiness, monolithic construction, totally enclosed, dust and water proof, system luminous efficacy of minimum 100 lumens per watt and a minimum system lumen output of not less than 3500 lumens, correlated colour temperature shall be minimum 5700 degree Kelvin, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, ingress protection of IP-65 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 270 V, AC, frequency 50-60Hz, potted type for humming free operation, driver shall withstand upto 400 V for 08 hours, surge protection not less than 10 KV, Power factor > 0.95, Total Harmonic Distortion (THD) shall be less than 15%, double phase protection, no load, open circuit and short circuit protection, suitable for ambient temperature from (-)10°C to 50°C and humidity level 10% to 90% RH, cool white colour and lamp starting time shall not be more than 10 second, PMMA/polycarbonate/toughened glass heat resistant cover, prewired and connecting up to street light feeder/junction box with & including 2.5 Sqmm 3 core PVC insulated, weather proof, multistranded copper conductor cable of 1100 Volt grade (ISI marked), complete all as specified and as directed. |
| 25 | NOTES FOR LED LIGHT FITTINGS :(i) All LED light/luminare shall meet the provision laid down in IS - 16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part -II / Section 13.(ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80.(iii) Contractor has to furnish a on site replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced free of cost in the following case :-(a) Manufacturing defects.(b) Failure due to mechanical and electrical impact.(c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries. |
| 26 | Supply and fixing wall mounting bracket (suitable for fixing/holding street/security light fittings) made of 40mm bore GI pipe ‘light grade’ not less than 1.20m long, bent to shape at required angle, fixed to wall with & including mild steel clamps (02 Nos) made out of flat iron 50x6mm with nuts, bolts & washers, complete all as specified and as directed. |
| 27 | Supply and fixing sheet metal enclosure, double door type, suitable for fixing MCBs, VTPN with 200 Amps rated copper bus bar, 4 way, 415 Volts, flushed in wall, fixed, complete all as specified and as directed.Note : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item. |
| 28 | Supply and fixing MCB, 6 to 32 Amps, Single Pole & Neutral, 240 Volts, 16 kA, ‘C’ Curve, with over load and short circuit protection, complete all as specified and as directed. |
| 29 | Supply and fixing MCB, 6 to 32 Amps, Single Pole, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, complete all as specified and as directed. |
| 30 | Supply and fixing MCCB, 4 Pole, 63 Amps, rupturing capacity 16 KA, 415 Volt grade, AC, 50 Hz, fixed Thermal - Magnetic, complete all as specified and as directed. |
| 31 | M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLSH with multi-stranded copper conductor, 1100 Volts grade, ISI markedcables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling complete all as specified & as directed.Notes :-(i) 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item. |
| 32 | Supply, assembling, hanging, fixing & testing Ceiling Fan of size 1200 mm sweep, minimum air delivery 210 CMM with service value 6.00 BEE, 5 star rated, with brushless direct current (BLDC) motor, single phase, AC supply, 230 Volt, with & including down rod, canopies, three number blades, capacitor 2.5 mfd, hook, rubber reel, safety pins, nuts, bolts, washers, cable connector and making connection with PVC insulated & sheathed 1 Sqmm three core flexible copper multistranded conductor cable (ISI marked) from ceiling rose to connector of ceiling fan including marking of SM / MES number with thick synthetic enamel paint of approved tint complete all as specified and as directed.Note :- The font, style & place of writing SM/ MES number with synthetic enamel paint on ceiling fan shall be as directed by the Engineer-in-Charge and cost thereof shall deemed to be included in quoted rates. |
| 33 | Supply and fixing Exhaust Fan made of sturdy Engineering plastic complete with louvers shutter, 300mm sweep, 230V, 50 Hz, 1200 RPM, Copper winding and connecting with & including 1 Sqmm, three core, flexible multistranded copper conductor cable and connected from ceiling rose to fan complete all as specified & as directed. |
| 34 | Material and labour Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI wire 4 mm dia (upto the test point / cross arms earth lead upto 7.5 meter length from top of earth plate) by means ofGI bolts/nuts/washers, protected by 15 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, Pit cover & frame including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of SSR Part-I. Notes :- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earth lead upto 7.5 meter length from top of earth plate. |
| 35 | Supply, fixing and testing of automatic operation single phase naturally air cooled indoor type Voltage stabilizer and designed for input variation between 170 volt to 250 volts with out put voltage stabilized 230 volt with accuracy of + 2.5% of capacity 1 KVA with mounting bracket complete with time delay relay complete all as specifief and as directed. |
| 36 | Supply, installation, testing and commissioning desert cooler (overall minimum size 26”x26”x33”) made of 18 Gauge galvanised sheet, depth of water tank shall be 11” (Minimum), electric driven, 230 Volt, Single Phase, 50 Hz, AC supply having nominal Air flow of 4000 cubic metre per hour, placed on platform/ stand including provision of PVC braided connection heavy duty 750mm long with brass union at both end for necessary water connection, Desert cooler comprising of the following:-(a) Float valve shall be deemed to be inclusive with cost of desert cooler.(b) Cooler fan motor, 145 watt, 1400 RPM, Single Phase, 450mm sweep, aluminium blades (Three number) Make : Crompton Greeeves Ltd/ Khaitan/ Cool home with standered clamps fixing to body of desert cooler.(c) ON/OFF switch for pump and motor along with three speed selector switch for fan.(d) Submersible pump 23 watt (Minimum) capacity, 220/240 Volts, Single phase, 50 Hz having lifting height 2 metre of make : Crompton/Bajaj as approved by GE.(e) Front adjustable grill both side i.e horizontally & vertically (f) Necessary cord with plug top for electric connection.(g) Three side slotted shutter with suitable pad as per standard practice.(h) Spray painting to external surface of cooler and anticorrosive rubber paint to internal surface of water tank portion. |
| 37 | Subtotal {Total of Schedule \"A\" Section-III (Part-II)} |
| 38 | SCHEDULE \"A\" SECTION-IV (ROAD/PATH WORKS) |
| 39 | Lump sum price worked out by the Contractor for “Road/ Path Works” as listed in Schedule ‘A’ Section-IV |
| 40 | SCHEDULE \"A\" SECTION-V (SEWAGE DISPOSAL WORKS) |
| 41 | Lump sum price worked out by the Contractor for “Sewage Disposal Works” as listed in Schedule ‘A’ Section-V. |
| 42 | SCHEDULE \"A\" SECTION-VI, Part-I (EXTERNAL WATER SUPPLY WORKS) |
| 43 | Lump sum price worked out by the Contractor for “External Water Supply Works” as listed in Schedule ‘A’ Section-VI (Part-I). |
| 44 | SCHEDULE \"A\" SECTION-VI, Part-II (EXTERNAL WATER SUPPLY WORKS) |
| 45 | M&L for tapping of 40mm water supply line connection from existing 150/100mm bore DI line including socket/Clamp/Tee including jointing complete all as specified and as directed. |
| 46 | Subtotal {Total of Schedule \"A\" Section-VI (Part-II)} |
| 47 | SCHEDULE \"A\" SECTION-VII, Part-I (EXTERNAL ELECTRIC SUPPLY WORKS) |
| 48 | Lump sum price worked out by the Contractor for “External Electric Supply Works” as listed in Schedule ‘A’ Section-VII (Part-I). |
| 49 | SCHEDULE \"A\" SECTION-VII , Part-II(EXTERNAL ELECTRIC SUPPLY WORKS) |
| 50 | Boring holes under main road, pavements, hardstanding by trenchless technology using ultra sound technique and necessary machine for accommodating upto 150mm bore pipe including all necessary returning filling & removal of surplus soil upto 50 m distance complete all as directed.Note : Pipe shall be measured & paid for separately under respective item of BoQ/Schedule \"A\". |
| 51 | Supply & fixing HDPE DWC pipe of outer dia 110mm and inner dia 95 mm for laying of cable laid in trenches complete all as specified and as directed.Note : Necessary earthwork shall be measured and paid seperately under respective item. |
| 52 | Subtotal {Total of Schedule \"A\" Section-VII (Part-II)} |
| 53 | SCHEDULE \"A\" SECTION-VIII (HOT WATER SUPPLY AND COOLING APPLIANCES WORKS) |
| 54 | Lump sum price worked out by the Contractor for “HOT WATER SUPPLY AND COOLING APPLIANCES WORKS” as listed in Schedule ‘A’ Section-VIII |
| 55 | SCHEDULE \"A\" SECTION-IX (EXCAVATION AND EARTH WORK) |
| 56 | Lump sum price worked out by the Contractor for “Excavation and Earth Work” as listed in Schedule ‘A’ Section-IX. |