Tender For Special Repair To Building No P- 16 At Guwahati Under Ge Guwahati.; 1 Taking down old defective chowkhats with shutter (without taking off shutters from the frame) n.exc 1.5 sq.m eachand removing away from site, complete all as specified and as directed. 2 Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed 3 Taking down old defective shutters of any description (wooden or aluminium) n. exc 1.0 sq.m each complete all as specified and as directed. 4 Taking down old defective shutters of any description (wooden or aluminium) exc 1.0 sqm but n. exc 2.0 sqm each complete all as specified and as directed. 5 Taking down cement plaster, any description, on brick or stone walls, etc.including racking out joints, hacking for key, scrubbing down with water, etc. including removal of rubbish material away from site, complete all as specified and as directed. 6 Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 finished even and fair complete all as specified and as directed. 7 Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and fair complete all as specified and as directed. 8 S&F 2nd class hardwood plain, solid, straight chowkhats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and as directed. 9 S & F flush door shutters, 30 mm thick, solid core of particle board construction, FAT-I or XPS designation, bonded with BWR adhesive with stiles, rails and lipping of timber as given in Group 2A and Group 2B of Annex B of IS 2202 (Part 1): 1999, both sides face panels of plywood as per IS 710: 2010, internally lipped complete all as specified and as directed. 10 S&F 35mm thick, 2nd class hard wood, Glazed andskeleton door shutters, open rebated and prepared to receive glass, gauze, etc. (with sash bars), but divided into squares, with plain, chamfered or rounded,mitred and rebated sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified inSSR Part I, Section 8, clause 8.24(a); supplied and fitted to chowkatscomplete all as specified and as directed. 11 Supply and fixing solid PVC door frames of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube all as per specification & drawing complete all as specified and directed. 12 S&F of Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC C channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rails on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying & fixing in the frame at site as per specification & drawing, complete all as specified and as directed. 13 M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. 14 S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 200 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed. 15 S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. 16 S & F cast aluminium alloy handle, cast type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. 17 S & F cast aluminium alloy handle, cast type, 100 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. 18 S & F 100 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed. 19 S & F 75 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed. 20 M & L for powder coated (colour) aluminium frame for doors, windows, ventilators (thickness of powder coating not less than 50 micron) with one or more rebates including joining cleat for fixing including handle, tower bolt, door stopper, grills etc. complete all as specified and as directed. Note:- Design/ pattern, profile sizes and other dimensions shall be of standard size and as directed. 21 M & L for powder quoted (colour) anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified and as directed. Note:- Design/ pattern, profile sizes and other dimensions shall be of standard size and as directed. 22 M & L for anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. including provn of glazing with 5mm thk glass fixed to frame, complete all as specified and as directed. Note- Note:- Design/ pattern, profile sizes and other dimensions shall be of standard size and as directed. 23 Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed. 24 Supply & fix sheet glass, ordinary quality, 3 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed. 25 Supply & fix tinted sheet glass, ordinary quality, 4 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed. 26 S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed. 27 S & F butt hinges, cast brass with galvanised mild steel wire pin, bright finished, hinge designation 100B11 as per IS 205: 1992 complete all as specified and as directed. 28 S & F exposed type hydraulically regulated door closers, universal closer, bottle type (type A), Designation No. 2, suitable for 36 kg to 60 kg mass of doors & 701 mm to 850 mm width of door, aluminium extruded sectioon bodycomplete all as specified and as directed. 29 Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc. 30 Demolition of cement concrete(unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) and complete all as specified and as directed. 31 M & L for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate, 25 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed. 32 M&L for 20mm thick granite (of any type as approved by Engineer-in-charge), work in cooking platform, in toilets for fixing wash hand basin, counter slab (table rubbed and polished), in steps, jambs, pillars, window cills and like, fixed in cement mortar 1:4 including pointing in white cement 1:2 using granite / marble dust with admixture of pigment to match with shade of granite, laid over and including 15 mm thick cement screed in CM 1:6, complete all as specified and as directed by Engineer-in-charge at site. 33 M & L for 20 mm thick marble (Makrana doongri Adanga) tiles machine cut, in skirting/dado laid over and including 15 mm thick backing in cement mortar 1:6 cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of marble stone including grinding and polishing complete all as specified and as directed. 34 M & L 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair as in plinth protection and making 50mm deep joints at every 3 mtr enterval and at every corners and filling the joints with bitumen grade 85/25 and sand mixture 1:3 complete all as specified and as directed. 35 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises 36 M&L for light shade vitrified ceramic tiles 10 mm thick (square / rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tile, laid over and including 15mm thick screed bed in CM 1:6, complete all as specified and as directed. 37 M & Lvitrified ceramic tiles light shade 9 to 10mm thickarea of each tile notexceeding 0.36 sqm, in skriting dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles, over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed. 38 M&L Non-skid ceramic colour tiles 7 to 8 mm thick , (square/rectangular), area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 15 mm thick screed bed in cement sand mortar 1:4 complete all as specified and as directed. 39 M&L for Glazed ceramic tiles on vertical surface of size 450X 350X 7-8mm or 300x200x7-8mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with shade of the tiles laid over and including 10mm thick rendering as backing coatin CM 1:4 with wire markings to receive tile over it, complete all as specified and as directed. 40 M & L for machine cut Kota stone slab flooring 20 to 25 mm thick over cement screed bed of 15 mm thick in cement mortar 1:3, laid and jointed with grey cement slurry, mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. 41 M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and directed. 42 S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. not exceeding 10 kg each brackets (Brackets over 10 kg each to be measured under Structural Steel) complete all as specified and as directed. 43 S & F for steel work of grade-3 as per IS 10748 in tubular trusses including special shaped washer etc. complete using ERW or HRIW welded tubes conforming to IS 1161: 2014 (Yst 240 Grade) complete all as specified and directed. 44 M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering/ wall clading fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. 45 M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. 46 S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge. 47 S & F hexagonal wire netting, size of aperture 20 mm, dia of galvanised steel wire 1.40 mm fixed with tinned tacks of wire staples complete all as specified and as directed. 48 Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. 49 M&L for preparation of old painted surface of steel and iron of any description, not otherwise described, over 10cm in width or girth and applying one coat of synthetic enamel paint, white or tinted complete all as specified and as directed. 50 S & F brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and as directed. 51 M & L in repairs for PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed. 52 Supply and fix in repairs PVC SWR Nahani/ Floor trap plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 50 mm, complete all as specified and directed. 53 S&F in repair PVC(SWR) pipes 75mm dia single socketed in any length with rubber ring joints fixed to walls/floor complete including clamps for securing pipe, complete all as specified and as directed. 54 S&F in repair PVC (SWR) Pipes single socketed in any length with rubber ring joints, 110 mm bore fixed to walls/floor, complete all as specified and as directed. 55 Cutting chases in brick walls to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., not exceeding 10 cm girth and making good the same with cement concrete M15 (Nominal Mix) using 12.5 mm nominal size coarse aggregate or cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 complete all as specified and as directed. 56 Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified. 57 Supplying & fixing to walls and ceilings or laid in floors 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. 58 Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified. 59 Supplying & fixing to walls and ceilings or laid in floors 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. 60 Taking up or down steel tubing and connections, bore of pipes 25 mm and removing away from site, complete all as specified and as directed. 61 Supplying & fixing to walls and ceilings or laid in floors 25 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. 62 S&F in repair rotational moulded polyethylene water storage tank 500 litre capacity of triple layered layer wall construction (Cylindrical, vertical with closed top) hoisted and fixed in position including 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule all as specified and as directed 63 S&F in repair rotational moulded polyethylene water storage tank 1000 litre capacity of triple layered layer wall construction (Cylindrical, vertical with closed top) hoisted and fixed in position including 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule all as specified and as directed. 64 S & F in repairs vitreous china wash basin, white, flat back, size 550 mm X 400 mm excluding taps but including CI brackets and waste pipe complete all as specified and directed. 65 M & L for 12mm thick, Block boardsgrade 2 quality, interior grade, decorative type with decorative face veneer on both face, commercial type, fixed with screws to timber frame-work fixed with screw/nails including 4mm thick teak wood lipping complete all as specified and as directed. 66 S & F in repairs brass chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed. 67 S&F vitreous china wash down water closet pan (Pedestal pattern) with P or S trap white, including connection to trap and cistern, flush pipe including PVC valveless syphonic action type flushing cistern 10 lit capacity low level white with inlet ball valve, float and handle, white plastic water closet seat cover, closed pattern with flat bottom & cover and aluminium anodised hinging device, 32mm dia PVC flush pipe and making good disturbed surface of floor, complete all as specified and as directed. 68 S & F in repairs vitreous china squatting pan, Orissa pattern, size 580 mm X 440 mm white with ‘P’ or ‘S trap, front or back inlet and integral foot rests, any pattern and including valveless syphonic action type flushing cistern 10 lt capacity low level white with inlet ball valve, fixing bolt, connector to flush pipe, lime concrete bedding and making connections to flush pipe, connector to branch pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed. 69 S & FVitreous China Urinal, full stall type, white of size 310x700mm including 40mm dia waste coupling and push cock (excluding flushing cistern, flush pipe and waste pipe), etc complete all as specifed and directed. 70 S & F in repairs 10 litres capacity, low level, syphonic type, white, plastic flushing cistern as per IS 7231: 1994 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed. 71 S & F in repairs 15 mm nominal size, pillar taps, cast copper alloy body and body components with capstan heads, spindle, washer plate and nut, with screwed shanks and back nut, with or without lettered hot or cold, nickel-chromium plated finish complete all as specified and as directed. 72 S&F bib taps with wall flange, fancy type, quarter / half turn, chromium plated, long body with capstan head and cup, screwed down, screwed for iron pipe or for brass ferrule including accessories, suitable for bore of pipe 15 mm, complete all as specified and as directed. 73 S & F 15 mm nominal size, nonrising spindle type fancy concealed stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed. 74 S & F in repairs sink made of stainless steel 1 mm thick sheet kitchen or laboratory with plugs, washers & 40 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant; including bedding in cement mortar to draft wall or including fixing cantilever brackets & connecting union to pipe, overall size 495 mm X 420 mm, bowl size 410 mm X 330 mm X 160 mm complete all as specified and as directed. 75 S & F sinks with drainage board made of stainless steel 1 mm thick sheet kitchen or laboratory with plugs, washers and 40 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipes overall size 915 mm X 460 mm bowl size 410 mm X 330 mm X 160 mm complete all as specified and as directed. 76 M&L for complete removal of existing treatment and applying two coats of 100% Premium acrylic emulsion paint havingVOC less tham 50 gm/ltrs and UV resistance as per IS 15489:2004, alkali and fungal resistanxe dirt resistance exterior paint of required shade with silicon additives @1.43 ltrs/10sqm over and including priming coat of exterior primer applied @0.90 ltrs/10 sqm over new surfaces complete all as specified and directed. 77 Material & Labour for complete removal of existing treatment of ceiling and applying two coats of oil bound distemper over a coat of compatible primer over a coat of 1.5 mm thick wall care putty complete all as specified and directed. 78 M&L for preparation of new surfaces and applying two coats of 100% Premium acrylic emulsion paint havingVOC less tham 50 gm/ltrs and UV resistance as per IS 15489:2004, alkali and fungal resistanxe dirt resistance exterior paint of required shade with silicon additives @1.43 ltrs/10sqm over and including priming coat of exterior primer applied @0.90 ltrs/10 sqm over new surfaces complete all as specified and directed. 79 Complete removal of existing treatment of wall and M & L for applying two coats of distemper oil emulsion over one coat of primer over 1mm thick POP to make smooth surfaces complete all as specified and as directed. 80 M & L for cutting out cracks to V section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand in ratio 1:1 (by weight) complete all as specified and as directed. 81 M & L for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate, 40 mm thick as levelling course of roof padding after roughening and cleaning of existing surface and brushing with neat cement slurry with 3kg of cement per sqm complete all as specified and as directed. 82 Material and labour for plastering 20 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound shall be measured and paid for separately. 83 M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top: (i) Taking out old roof tratment and roughening tha same old concrete slab by picking, sweepingc clean and washing down with water to remove dust etc. (ii) Screed bed or bedding layer of mortar 15mm thick in CM 1:4 for laying as in roof slab with mixing of WPC and surface finished fare and smooth without using extra cement (WPC shall be measured and paid seperately) (iii) Cleaning the plastered roof surface and applying one coat of cold bituminuous primer @ 0.25 ltr/Sqm confirming ti IS: 3384 -1986 (iv) APP based polymeric menbrane 3mm thick (minimum) weighing 3.5 kg/Sqm reinfiorced with polyster non woven fabric (weighing not less than 160gms/Sqm) shall be less appliedb over bituminous primer as specified above over a application of polymeric membrane shall by torch application. The overlaps shall be minimum 100mm on the teransverese direction and 75mm on longitudinal direction. (v) Applying one coat of aluminium paint over the APP modified membrane @ 0.11Kg/sqm. 84 S&F in repair reflection looking mirror of size 600x450mm fixed to wall with chromium plated brass screws and cup washers complete all as specified and directed. 85 Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed. 86 M & L for brick work with sub class B bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed. 87 M & L for anodised aluminium snap grid frame work for false ceiling of size 605 mm x 605 mm in true horizontal level complete all as specified and as directed. 88 M & L for 4 mm thick plain fibre cement flat sheets type B, any category as per IS 14862: 2000 (non-asbestos) building boards, fixed to timber/GI /Aluminium framework with screw complete all as specified as directed. 89 M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height complete all as specified and as directed. 90 M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and as directed. 91 M & L for cement concrete in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) in M5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 92 S & F in repairs 20 mm dia harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and as directed. 93 S & F brass chromium plated brackets decoorative for curtain rods complete all as specified and as directed. 94 M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. 95 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. 96 Taking down main switch/MCB DB/ sheet metal enclosure by disconnecting the electric supply including MCB/MCCB/Cut out etc. any type and size complete all as specified and as directed. 97 M & L for point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC concealed conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk type pressed steel / welded MS terminal boxes made out of 1.20mm MS sheet, 3mm thick modular top cover for mounting of modular fittings, switches, sockets, regulators etc suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.Note:- Cutting chases and making good in CM (1:3) are deemed to be included in quoted rate. 98 M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC concealed conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 99 M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC concealed conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 100 M & L for point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 4 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 101 Supply and fix sub main wiring complete with and including four Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 10 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC concealed conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 10 sqmm two Nos single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed. Note (i) Four runs of 10 sqmm cable, two runs of 10sqmm cable and one run of conduit shall be measured and paid as one unit length. (ii) Cutting chases and making good in CM 1:3 and finishing to match with the existing surfaces are deemed to be included in the quoted rate. 102 Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including taking down old sub main wiring complete all as specified and directed. Note - (i) Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length.(ii) Cutting chases and making good in cement mortar 1:3 and finishing the surfaces to match with the existing are deemed to be included in the quoted rate. 103 Supply and fixing of concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 4 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including taking down old sub main wiring complete all as specified and directed. Note - (i)Two runs of 4 sqmm cable, one run of 4 sqmm cableand one run of conduit shall be measured and paid as one unit length. (ii) Cutting chases and making good in CM 1:3 and finishing to match with existing surfaces are deemed to be included in the quoted rate. 104 S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. 105 Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. 106 Supply and fixingLED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. 107 S & FLED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. 108 S & F Bayonet plastic lamp holder, 2 A, 250 V, ordinary, backplate, non-switched, unenclosed, without T marking, B22d complete all as specified and as directed. 109 Supplying, installing, testing & commissioning, storage water heater (geyser), 50 litres capacity, standing loss less than 0.742 Kwh per day for 45⁰C difference of temperature as per IS 2082 (five-star rated as per BEE), reheating time less than 60 minutes, mixing factor less than 20%, shock proof high density PUF insulation body material, glass lined inner tank material having warranty 7 years on tank material, 4 years on heating element and 2 years on other spares parts comprising following fittings (a) glass coated incoloy element (b) capillary type thermostat (c) digital display unit (d) thermal cutout (e) multifunction valve (f) earth leakage circuit breaker (g) magnesium anode rod cathodic protection (h) flexible cable of suitable length with 3-pin plug of 16A capacity (i) drain plug (j) fusible plug fitted on the crown of water heater with operating temperature between 100⁰C to 110⁰C including fixing by grouting and fastener complete all as specified and as directed. 110 S & F exhaust fan, AC, 50 Hz, single phase, 230 V, 450 mm sweep, 4 pole, heavy duty, metal body, 4 Nos blades, Insulation Class A, ISI marked including capacitor to ensure power factor more than 0.9 including louvers complete all as specified and as directed. 111 Taking down ceiling fan, any sweep by unscrewing the U clamp, cleaning the ceiling fan with moist cloth with detergent powder, scrubbing the old paint with sand paper and painting it with super quality synthetic enamel paint of white colour and rehanging the same after replacing the flexible copper conductor of suitable dia, new fan hook of suitable length and down rod complete all as specified and as directed. 112 S & F modular switch, 1 way, 6 A, 1 module complete all as specified and as directed. 113 S & F (3 pin and 2 pin) combined modular socket outlets (ISI Marked), 6A, 2 modules, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed. 114 S & F modular switch, 1 way, 16 A, 1 module complete all as specified and as directed. 115 S & F (3 pin and 3 pin) with common earthing pins, combined modular socket outlets, 6A & 16A, 2 modules, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed. 116 S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed. 117 S & F in repair Modular fan regulator, 120 W, 2 modules complete all as specified and as directed. 118 S & F in repair of vertical double door MCB Distribution board of sheet metal enclosure, triple pole and neutral, 4 way with 200 Amps rated bus bar, 415 volt, IP42 protection grade for housing MCCB as incomer (except MCCB) inclluding cutting chases for sinking of boxes and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 119 S & F in repair double door MCB Distribution board of sheet metal enclosure, triple pole and neutral, 4 way with 200 Amps rated bus bar, 415 volt, IP43 protection grade and fixed with MS hold fast and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate,including taking down old unsv DB, complete all as specified and as directed. 120 S & F in repair double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 8 way with 200 Amps rated bus bar, 240 volt, IP43 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 121 S & F MCCB, Fixed Thermal & Fixed Magnetic setting, 4 pole, 415 volts, 16 kA, 125 A complete all as specified and as directed. 122 S&F MCB TPN 63 Amp C series 10KA 415 volts complete all as specified and as directed. 123 S&F MCB, SPN, 240 volts, C Curve, 32 Amps 10 KA complete all as specified and directed. 124 S & F circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. 125 M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 15 mm dia GI pipe light grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed. 126 Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed. 127 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed. 128 Removing excavated material (excluding hard rock) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. 129 Supplying & laying in trenches 80 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. 130 Supplying & laying in trenches 40 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. 131 M & L for non-rising stem type sluice valves having double flanged for connections of nominal pressure (PN 1.6) as per IS 14846: 2000 of preferred materials, nominal size 80 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed. 132 S & F 40 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete 133 M&L for bricks, common burnt clay building bricks, sub- class B designation 75 complete all as specified and directed. 134 Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 70 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.