| Sl. No. | Item Description |
| 1 | Petty repair to door shutters for easy closing/opening(size upto 3 Sqm) including minor repair and easing, adjustment/aligmentto openable with accessories and including taking down and refixing, tightening of hinges or changing the position of hinges,welding of hinges door to frame adjustment of tower bolts, sliding bolts with new screws etc,complete all as specified and directed. |
| 2 | Petty repair to wooden door,skelton door,flush door, wooden window, wooden ventilator, cupboard door, wardrobe door,PVC door with shutter (size upto 3 Sqm) including roller, windows, etc with minor repair and easing and adjustment/alignmentto openable with assessories and including taking down and refixing complete all as specified and directed. |
| 3 | Taking down chowkhat or frame (wooden/steel) exceeding 1.50 Sqm not exceeding4.0 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed. |
| 4 | Taking down shutters of any description exc 1.0 Sq.m andn.exc 2.0 Sq.m each complete all as specified and directed. |
| 5 | M&L Second class hard wood plain, solid, straight Chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at jointscomplete all as specified and directed. |
| 6 | S&F 2nd class hard wood 35mm thick Factory made plain framed panelled shutter any number of panelswith lock rail and panel of 9mm BWP commercial ply or 12mm veneered partical board with commercial veneering on both faces. The size of rail and stile as per IS 1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 7 | S&F Factory made 35mm thick Glazed and skeleton shutters/windows, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a);all as specified and directed. |
| 8 | S&F aluminium handles cast type anodised 200 mm long complete all as specified and as directed. |
| 9 | Supply and fixing 100mm long Butt hinges medium weight cold rolledstainless steel, and fixed complete all as specified and as directed. |
| 10 | Supply and fixing 200 mm long aluminium anodized barrel tower bolt extruded section complete all as specified and as directed. |
| 11 | S&F 250mm aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extrudud sections or cast aluminium alloy and fixed complete all as specified and as directed. |
| 12 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete all as specified and directed. |
| 13 | Preparation of new wood orwoodensurface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed |
| 14 | Supply and Fixing 30 mm thick factory made flush shutter solid core construction with block board core and plywood face panels, comercial type on both faces complete all as specified and directed. |
| 15 | S&F decorative laminate type -1, 0.90mm thick of surface finish, colourand pattern as approved, fixed with approved adhesive as per manufacturer\"s instructions complete all as specified and directed. |
| 16 | Supply and fixing in repairs 150 mm long aluminum anodized barrel tower bolt extruded section complete all as specified and as directed. |
| 17 | S&F in repairs 300mm, ordinary Mild steel rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 18 | S&F 5mm thick rubber beading strips of entrance doors having width exc 3cm and not exc 5cm to arrest entry of insects including taking down existing one complete all as specified and as directed |
| 19 | Supply and fixing in repairs aluminum handles cast type anodised 150 mm long complete all as specified and as directed. |
| 20 | Supply and fixing in repairs butt hinges 75 mm long medium weight cold rolled stainless steel complete all as specified and as directed. |
| 21 | M&L for 22mm to 25mm dia mild steel powder coated drapery rod cut to length required without joint in between and including Mild steel powder coated fancy type brackets etc and fixed at openings including taking down existing old one complete as directed. |
| 22 | Applying silicon sealent on joints of wall, cill, jambs, roof etc complete all as specified as directed |
| 23 | Taking down chowkhat or frame (wooden/steel/aluminium) not exceeding1.5 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed. |
| 24 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube complete all as specified and directed. |
| 25 | S&F Factory made Solid PVC Door Shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails.MS frame shall be covered with heat moulded plain colour PVC\"C\"channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail.Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitablePVCsheetbeadingand jointed together with solvent cement complete all as specified and directed. |
| 26 | S&F Butt hinges 75 mm long medium weight cold rolled stainless steel complete all as specified and as directed. |
| 27 | Supply and fixing aluminium handles cast type anodized 150 mm long complete all as specified and as directed. |
| 28 | Supply and fixing 150 mm long aluminium anodized barrel tower bolt extruded section complete all as specified and as directed. |
| 29 | S&F in repairs Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete all as specified and directed. |
| 30 | M&L Hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel frames glazed with putty or fixed with beads and material and labour for4mm thick plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area not exc 3 Sqcm and glass not exc 0.5 Sqm in each pane complete all as specified and directed. |
| 31 | M&L Hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel frames glazed with putty or fixed with beads and material and labour for4mm thick plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area not exc 3 Sqcm and glass exc 0.5 sqm in each pane complete all as specified and directed. |
| 32 | Providing and injecting chemical for post constructional Anti TermiteTreatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same all as specified and directed. |
| 33 | Supply & Fixing of UPVC glazed 3 track-2 panel sliding windows with mesh made out of multi chambered uPVC sections with TPE gaskets having isolated drainage and reinforced with Galvanized iron profiles throught out the window. The outer frame having an overall size of 108 x 48 mm with reinforcement of 1.2mm thickness and sash with overall size of 38 x 61 mm with reinforcement of 1.2 mm thickness mesh sash of overall size 38 x 58mm Fiber mesh reinforced with 1.2 mm of GI. Glazing bead for fixing of glass shall be of size 16mm x 19mm and TPV gasket. Windows will be provided with 5mm thick plain float glass, With \"Astrapia\" hardware or equivalent & Single point locking system of flush lock. Wall thickness of frame & sash shall be 2-2.2mm complete all as specified and directed. |
| 34 | Petty repair to toilet floor, bathroom, kitchen, etc seepageincluding sunken portion treatment with apply water proofing compound including repair and arrest the leakage to floor trap,nahani trap , grating and applying white cement etcmaking good to the damaged portion of flooring, laying and matching of existing flooring, complete all as specified and directed. |
| 35 | Treating the sunken floor slab comporising of the following specifications all as specified & directed:- |
| 36 | (a) Demolition of cement concrete of any description in sunken portion of toilet and removing debris outside MD land. |
| 37 | (b) Cleaning the sunken/ lowered portion of RCC slab surfaces (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely and providing 40mm thick (avg) PCC 1:2:4 type B-1 using 20mm graded aggregate as in padding concrete to achieve proper slope including cutting holes in bricks or RCC wall for provision ofspout (WPC measured and paid separately) |
| 38 | (c) Rendering of uneven surfaces with 10mm thick CM 1:4 mixed with required water proofing compound as per manufacturer instruction. Fill it with water and check dampness and seepage. Where dampness/ seepage is noticed, nozzles shall be fixed and grouting carried out. (WPC shall be measured and paid separately). |
| 39 | (d)All junctions points of side wall spout where CI/ GI pipes are passing through shall be sealed with epoxy putty. |
| 40 | (e)After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. |
| 41 | (f) Applying two coats of polymer modified cementious water proof coating as per manufacture instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed. |
| 42 | (g)Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound as per manufacturers specification including rounding of corners and junctions sloping towards spout. (WPC shall be measured & paid separately). |
| 43 | (h)Material and labourfor PCC 1:5:10 type E2, using 40mm thick aggregate n exc 150mmthick as in filling of sunken floor portion complete all as specified & directed. |
| 44 | (j) Material and labourfor PCC 1:2:4 type B1 using 20mm graded aggregate, 50mm tnick as in floor etc complete all as specified & directed. |
| 45 | Note :- (a)Testing of water proof area (ponding test) shall be done by filling water for at least 72 hours and tested for leakage, seepage to the entire satisfaction of GE. |
| 46 | (b) Test shall be done in presence of Engineer-in-Charge. |
| 47 | (c)The treatment shall be carried out by authorised applicator of chemicals. |
| 48 | (d)Cost of testing is included in the unit quoted rate above. |
| 49 | Material and labourfor Water proofing treatment to the sunken portion applying two coat of two component (1 part Polymer and second part cementations powder) cementations, polymer modified elastomeric, water proofing coating composed of cement, properly selected and graded aggregates, additive and acrylic emulsion polymer as a binder apply first coat of (mix and application as per manufacturer’s instructions) all over floor surface. Prepared surface and apply to vertical surface up to 15cm from tiling level, allow to dry 4 to 6 hours. Prepare for apply 2nd coat perpendicular to first coat and allow to dry 4 to 6 hours. All joints to Trap/WC/Soil pipe shall be properly sealed with sealing compound/polymer modified mortar using Dr Fixit Pidicrete UBP or equivalent in M/s Pidilite orM/s Sika Chemical, Slope of slab shall be towards and including GI pipe 50mm dia of suitable length Spout pipe. Providing 15mm protective screed with cement mortar in 1.3 with WPC (Make : Dr Fixit LW + or equivalent in M/s Pidilite orM/s Sika Chemical) within 2 to 3 days of second coat complete all as specified as per manufacturer instructions. Make : Dr Fixit Pidfin 2K or equivalent in M/s Pidilite orM/s Sika Chemical complete all specified and directed by Engineer-in-Charge. |
| 50 | Note :- The work shall be carried out by authorised and qualified applicators of the above mentioned manufacturer. |
| 51 | S & F in repair vitreous china squatting pan \"Orissa pattern \" size 580 x 440mm white with integral foot rests incl connecting to \"P\" or \"S\" trap and to flush pipe anti syphonage pipe etc compete including provn of lime concerte bedding and making good to floor complete all as specified and as directed. |
| 52 | S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/trenchesbore of pipe 75 mm with PVC clamps and saddles including taking down existing pipes and Dismantling of old unserviceable cast iron/RCC/PVC drain pipes jointed in cement mortar and taking out from trenches or walls of any bore including fittings complete all as specified and as directed |
| 53 | S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/trenchesbore of pipe 110 mm with PVC clamps and saddles including taking down existing pipes and Dismantling of old unserviceablecast iron/RCC/PVC drain pipes jointed in cement mortar and taking out from trenches or walls of any bore including fittings complete all as specified and as directed |
| 54 | S & F in repairs PVC (SWR) bends of any radius with access door bore of pipe 75 mm complete all as specified and as directed. |
| 55 | S & F in repairs PVC (SWR) bends of any radius with access door bore of pipe 110 mm complete all as specified and as directed. |
| 56 | S & Fin repairs PVC (SWR)junction single (single T)equal or unequal with access door bore of pipe 75 mm complete all as specified and as directed. |
| 57 | S & Fin repairs PVC (SWR)junction single (single T)equal or unequal with access door bore of pipe 110 mm complete all as specified and as directed. |
| 58 | S & F in repairs 125/ 110 mm bore PVC (SWR) floortrap plain with grating incl jointing with solvent cement complete all as specified and as directed. |
| 59 | S&F in repairs PVC (SWR) floor trap 75mm dia of outlet pipe, plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 60 | S&F in repair stack clamps made out of 50 mm x 5 mm flat iron and 110 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or rooffor 110 mm bore complete all as specified and directed. |
| 61 | S&F in repair stack clamps made out of 50 mm x 5 mm flat iron and 75 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or rooffor 75 mm bore complete all as specified and directed. |
| 62 | Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) and removing rubbish off from premises & M&L for joint free non skid coloured ceramic tiles 7 to 8 mm thick area of each tile not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointedin white or coloured cement to match incl 15 mm thick screed bed in cement mortar 1:4 for layingfloor finishes complete all as specified and directed. |
| 63 | Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) and removing rubbish off from premises & M&L forceramic coloured tiles of size 350mmx250mm/ 300mm X 450mmx7 to 8 mm thick, on vertical surfaces, set and jointed in neat cement slurry and pointed in coloured / white cement to match the tiles inc rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces as in backing coat to receive wall tiles etc complete all as specified and directed. |
| 64 | M&L Repair to ends of chajjas/ parapets by removing old concrete,loose material &cleaning of the reinforcement and finishing the surface with rich cement mortar 1:3 , finished fair & even and making good with existing finishes complete all as specified and as directed.Note: Rate quoted by the tenderer shall be deemed to inclusive of double steel scaffolding. |
| 65 | Taking down cement plaster on brick or stone walls, or concreteetc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises and leaving the work clear of any plastering and Material and labour for Rendering 15 mm thick in two layers onbrick or stone or concrete surfaces,first coat 10mm thick in cement mortar1:4 and 2nd coat 5mm thick in cement mortar1:4 finished even and smooth without using extra cement completeall as specified and directed.Note :-(a) The unit rate quotedis deemed to include for removal of accumulated earth of any width and depth upto 15 cm cleaning/cutting the grass with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 3 m from plinth protectionto outside MD land. |
| 66 | M&L rendering 10 mm thick in CM 1:6 on brick/stone/concrete surfaces finished even and smooth without using extra cement incl taking down cement plaster on brick or stone walls, or concreteetc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premisesall as specified and directed. |
| 67 | SupplyOnly integral water proofing compound complete all as specified and as directed.Make:-Dr. Fixit Pidi Proof and equivalent. |
| 68 | M&L preparation of newly plastered surfaces and applying three coats of white washing on walls surfaces complete all as specified and directed. |
| 69 | M&L applying two coat of cement based paint over a coat of primer, including preparation of newly plastered wall surfaces of any description, complete all as specified and as directed. |
| 70 | M&L for Preparation of old decoratedplastered or unplastered surfaceof wall, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spots and applying one coat ofoil bound distemper complete all as specified and as directed. |
| 71 | Material and labourfor Preparation of old decoratedplastered or unplastered surfaceof wall, chajja,ceiling, balcony, facia etc., brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent, trading, oil, greasy spots and applyingone coat of whitewashcomplete all as specified and directed. |
| 72 | M&L for Preparation of old painted wooden surface of any description and applying one coat of synthetic enamel paint, not otherwise described over 10 cm width or girth, complete all as specified and directed. |
| 73 | M&L for Preparation of old painted surfaces of steel and applying one coat of synthetic enamel paintover 10 cm width or girth, not other wise describedcomplete all as specified and as directed. |
| 74 | Petty repair to internal/external water inlet GI/CPVC pipe line of any size coming from over head tank to the quarter including socket,elbow,nipple ,with repair to water blockage , pipe line leakage, cleaning internally , removing of air/dust blockageincluding concealed water tubing etc n exc 3m length of any height using scaffolding as required and making the water supply functional complete all as specified and directed. |
| 75 | Supply and fixing 15mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing and connection complete all as specified and directed.. |
| 76 | Supply and fixing 20 mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing and connection complete all as specified and directed. |
| 77 | Petty repairs to leaking water in bib taps, pillar cock, stop cock, angle valve, concealed stop valve, bottle trap of any description by changing thePVC washers/ Sheet washers,spindle brass,jumper brass or any other minor accessories items etc (incl taking down and refixing) complete all as specified and directed |
| 78 | S&F in repairs pillar tap standard of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-110gms) complete all as specified and directed. |
| 79 | S & Fin repair bib tap standard of PTMT any colour screwed for iron pipe and fixed,15 mm bore (minimum weight 90gms) complete all as specified and as directed. |
| 80 | S&F in repairs Vitreous China urinals, half stall Urinal type (back or corner wall type), complete including providing and fixing plugs, Urinal spreader, CP push cock, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe, complete all as specified and directed. |
| 81 | S&F in repairs 40 mm Waste coupling fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed one complete all as specified and as directed. |
| 82 | S & F in repairs pillar tap with capstan heads chromium plated fency type screwed down high pressure with or withoutletter \"Hot\" or \"Cold\" with long screwed shanks and flynuts screwed for galvanised iron pipe and fixed complete for 15 mm bore complete all as specified and as directed. |
| 83 | S&F in repairs grating doom 125mm dia with waste hole of Chromium plated (Min wt 40 gms) complete all as specified and as directed. |
| 84 | S&F in repair vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, Urinal spreader, CP push cock, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and directed. |
| 85 | S&F in repairs of Push tap any colour high pressure of PTMT screwed for iron pipe and fixed, (Minimum weight 15mm-47gms)and complete all as specified and as directed. |
| 86 | S&F in repairs of swivel Shower with arm of PTMT any colour and 195mm long bend of 45 degree with flange for fixing with 15mm pipe (Minimum weight 15mm-90gms) complete all as specified and directed. |
| 87 | Supply and fixing in repairs plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device all as specified and directed. |
| 88 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including taking down existing one complete all as specified and as directed. |
| 89 | S&F in repairs 40mm bore unplasticised PVC pipe of pressure rating 10 kgf/Sqcm fixed complete to walls, ceiling or laid in floors complete all as specified and directed. |
| 90 | S&F in repairs Stop Valve standard of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-90gms) and directed. |
| 91 | S & F in repairs bib taps short/long body cast copper alloy chromium plated fancy type screwed down screwed foriron pipe or for brass ferrule and fixed for 15 mm bore complete all as specified and as directed. |
| 92 | S&F Rotational moulded polyethylene water storage tank of500 Ltrs capacity cylindericalvertical with closed top including 3 Nos GI check nuts and tank nipple of 25mm bore for inlet and outlet, 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball hoisted and fixed in position all as specified in SSR part -I including taking down old unserviceable tank complete all as specified and directed. |
| 93 | Taking down & re fixing high or low level flushing cistren 10 ltrs capacity & connections to pipes & fixing of chain & pull or lever after cleaning inside of all dirt, scale formation, replacement of rubber washers, syphon set, flush handle, float valve,stopping of leakage etc complete all as specified and as directed. |
| 94 | S & F in repairs PVC low level flushing cistern 10 Lit capacity including necessary brackets incl connecting flush pipe etcand making good the disturbed surfaces complete all as specified and as directed. |
| 95 | S&F in repairs Overhead Shower rose ø125mm (Brass Chrome Plated)complete all as specified and as directed. |
| 96 | S&F in repair Chromium platedsoap dishincluding fixing arrangement complete all as specified and directed . |
| 97 | S&F Towel Ring roundn exc 20cm dia stainless steel material fixed to wall with brackets including taking down existing one all as specified and as directed. |
| 98 | S&F in repair Toilet paper holder box type of vitreous china fixed to walls with chromium plated (CP) brass screwsand complete all as specified and as directed. |
| 99 | S&F in repairs of chromium plated tubular towel rail 20 mm dia brass D type 60 cm long between flanges complete all as specified and as directed. |
| 100 | S & F in repairs 15 mm dia stop valves of cast copper alloy fancy type chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and as directed. |
| 101 | Supplying and laying of 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and including taking out old steel/plastic/cpvc water tubing and connections complete as directed. |
| 102 | Supplying and fixing in repairs of 25mm outer dia Female Brass Threaded Adaptor (FTA/ FBTA CPVC complete all as specified and directed. |
| 103 | Supplying and fixing in repairs 25mm outer dia CPVC brass elbow all as specified and directed. |
| 104 | S&F Rotational moulded polyethylene water storage tank of1000 Ltrs capacity cylindericalvertical with closed top including 3 Nos GI check nuts and tank nipple of 25mm bore for inlet and outlet, 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball hoisted and fixed in position all as specified in SSR part -I including taking down of old unserviceable tank complete all as specified and directed. |
| 105 | S&F PVC connections 15mm size with PTMT nuts of length 450 mm including taking down existing old one complete all as specified and directed. |
| 106 | S&F 32 mm Waste Coupling fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed including taking down existing old one complete all as specified and as directed. |
| 107 | S&F CP sink cock with swinging casted round shape spout screwed down screwedfor iron pipe in repairs 15mm bore including taking down existing one complete all as specified and as directed. |
| 108 | S&F in repairs Wash basin vitreous china (flat back or angle back type) size 580x400mm including taps wastechain and plug and porceline stopper but brackets including cutting for and pinning inends of brackets or erecting stand with waste pipe, complete all as specified and directed. |
| 109 | S &Fin repairs PVC connection pipe 15 mm dia, 600 mm long with check nut and bolt with washer complete all as specified and as directed. |
| 110 | S & F in repairs vitreous china wash down water closet (Pedestral pattern) EWC white incl plastic water closet seat cover and mild steel chromium plated or aluminium hinging device and connecting to \"P\" or \"S\" trap incl connecting flush pipe with flushing rim complete all as specified and as directed. |
| 111 | S&F in repairs PVC waste pipe 32/40mm bore for WHB, Urinal & Sink complete all as specified and as directed. |
| 112 | S&F in repairs CP 2 way bib cock with wall flange fancy type chromium plated screwed down screwedfor iron pipe for 15mm bore complete all as specified and as directed. |
| 113 | S&F CP Concealed stop cock, Regular body with adjustable wall flange screwed down screwedfor iron pipe15mm bore including taken down existing one complete all as specified and as directed. |
| 114 | Supply and fixing in repairs 20mm dia gun metal gate valve with iron wheel screwed both ends for iron pipe complete all as specified and directed. |
| 115 | Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and taking out old steel/plastic/cpvc water tubing and connections complete all as specified and directed. |
| 116 | Supplying and fixing in repairs of 20mm outer dia Female Brass Threaded Adaptor (FTA/ FBTA CPVC complete all as specified and directed. |
| 117 | Supplying and fixing in repairs 20mm outer dia CPVC brass elbowall as specified and directed. |
| 118 | S&F in repairs Glass self assembly of 12mm thick andn exc 60cm length, 15cm wide with stainless steel brackets, stainless steel railing in bathroom and fixed to wall with brackets complete all as specified and as directed |
| 119 | S&F 300mm arc size, 5mm thick corner glass shelf with stainless steel brackets, stainless steel railing in bathroom and fixed to wall with brackets including removing the existing fitting as per manufacturer\"s instructions and as required at site complete all as specified and as directed |
| 120 | S&F PVC body cabinet box mirror of size 350mm X 450mm X 100mmPTMT alloy of approved pattern and design including taking down existing one complete as directed. |
| 121 | Petty repair to wall mixer,basin mixer,sink mixer etc including replacement of spindle brass, Jumper brass, rubber washer, head included taking down and refixing etc all as directed. |
| 122 | S&F in repair Brass Chromium plated wall mixer for mixing hot & cold water screwed down for 15mm bore iron pipecomplete all as specified and directed . |
| 123 | M&L Machine cut kota stone slab 20-22 mm thick as in flooring, laid over and incl 20 mm thick screed bed in CM 1:3 set and jointed in neat cement slurry and pointed with cement and pigment to match the shade of the slab incl rubbing and polishing including demolition of existing cement concrete and disposal of demolished material upto MD land complete all as specified and directed. |
| 124 | M&L 18 to 20 mm thick sadarhalli stone polished in floors/wall set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over andincluding screed bed or bedding layer, 15 mm thick in Cement Mortar 1:6complete including dismantling of existing stone slab and disposal to outside MD land complete all as specified and directed. |
| 125 | Supply and fixing in repairs 7 feet 4 pipespulley operated cloths drying system consisting of aluminium pipe of outer dia 22mm, inner dia 19.80mm,made up of detrin with rope guide mounted on channel pair of length 24 feet (distance between two pipes is adjustable) locking system to hide rope knot, channel to be mounted or fixed with self taping screws provided in kit. Rope will be HDPE double core of 4mm dia fixing to ceiling as specified and directed by Engr-in-Charge and minimum weight of one pipe shall not be less than 0.20kg/, minimum weight of rope shall not be less than 7700Gms/unit. Make : Easydry or equivalent. |
| 126 | Petty repairs to refixing the existing Wash hand basin and Sinks made of stainless steel 1mm thick kitchen flat back including fixing cantilever CI/Angle iron brackets embedded in concrete block including connecting waste coupling 32mm bore, including bedding, waste fitting, waste pipe in cement mortar on to dwarf wall and connecting union to pipe, filling gap in white cement and all necessary fittings to fixed in repair(including taking down and refixing the same position) complete all as specified and directed. |
| 127 | S&F sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortarto dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm fixed in repairsall as specified and directed. Make : M/s Diamond / Nirali / Amco / TATA or equivalent |
| 128 | S&F Sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall orincluding fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm fixed in repairsall as specified and directed. |
| 129 | Removing plant/Uprooting of vegetation growth including roots on wall/roof/parapet near pipes etc and applying acid treatment afterremoving roots for preventing regrowth and making good disturbed surfaces/area in superficial area exc 150sq.cm but n.exc 400 sq.cm and averaging depth not exceeding 10 cm by using PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) or 10mm thick plastering in cement mortar 1:3 as required and finishing the surfaces to match with the existing surface complete all as specified and directed. |
| 130 | M&L for providing and laying / fixing TPO membrane of non-flammable waterproofing of roof which shall be 1.5mm thick loose laid membrane using Fosroc Proofex ORG membrane, layers are overlaped to achieve a minimum weld of 110mm. Hot air welding can be either hand applied or by means of automatic machines and the roll\"s either end are overlapped with 110mm are in staggered position and the membrane shall be laid over the layers of non-woven geotextile fiber. The seperation layer provided to prevent the mechanical abrasion and cushioning between the fosroc proofex ORG membrane and the concrete substructure . The termination of fosroc proofex ORG by aluminium strip anchoring.Note: Work shall be executed directly by manufacturer or through their authorized and qualified applicators,of any following manufacturer only. M/s Fosroc chemicals, M/s Thermax Limited, M/s Tiki Tar Danosa India Ltd |
| 131 | Grinding of existing mozaic/kota stone/tiles in wall/flooring including mirror polishing, cleaning of tiles/granite and joints filling and apply white cement,including grouting of floor trap surroundings with white cement complete all as specified and directed. |
| 132 | M&L Vitrified Ceramic tiles 8-10 mm thick, lightshade (square/ rectangular) polished, area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over andincluding screed bed or bedding layer, 15 mm thick in Cement Mortar 1:6complete including dismantling of existing old flooring tiles and disposal to outside MD land complete all as specified and directed. |
| 133 | M&L Vitrified Ceramic tiles 8-10 mm thick, lightshade (square/ rectangular) polished, area of each tile not exceeding 0.36 sqm, in vertcal surfaces such as skirting/ dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over andincluding screed bed or bedding layer ,15 mm thick in Cement Mortar 1:6complete including dismantling of existing old tiles and disposalto outside MD land all as specified and as directed. |
| 134 | Material and labourfor 25 mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in flooring surface as in level course etc including demolition of existing old cement concrete, including disposal of demolition material upto 500mtr from MD land complete all as specified and directed. |
| 135 | Material and labourfor Preparation of old decoratedplastered or unplastered surfaceof wall, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spots and applying one coat of cement based paint complete all as specified and as directed. |
| 136 | M&L for Preparation of old decorated surfaces of wallsby using pressure washer, remove all dirt & dust ,applying 1mm thick wall care putty and two coats of premium oil bound distemper over one coat of primer as per manufauturer instruction of required shade complete all as specified and directed. |
| 137 | M&L for Preparation of old decorated wall surfaces including cleaning with water, rubbing offungus complete removal,applying two coat of weather proof paint \"APEX\"exterior wall paint including necessary preparation to give uniform and smooth finish all as specified and directed. |
| 138 | S & F MS Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161-1979 grade St.-240 complete all as specified and directed. |
| 139 | M & L for 0.50mm thick Pre painted Galvalume aluminium zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of old corrugated AC/fibre/GI sheet of any pattern in roof including ridge complete all as specified and directed. |
| 140 | M & L Providing two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces over 10 cm width or girth including preparation of new steel surfaces all as specified and directed. |
| 141 | M & L for 75 mm thick PCC type C1, 1:3:6 (using 20 mm graded aggregate) in plinth protection,finishing the surface even and smooth with using extra cement, including necessary demolition of old concrete all as speecified and as directed. |
| 142 | Supply and fixingAnodized aluminium size 605 x 605 mm snap grid frame work for false ceiling as per manufacturer instructions, with suitable size GI wire Hangers (up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long and6mm thick Non asbestos fibre cement building boards, fixed to sheet suitably placed in false ceiling grid made of Aluminium as per specification and drawing and including dismantling old unservicable ceiling board & frame of any type and description, complete all as specified and directed. |
| 143 | Taking down andre-fixing the same existing aluminium door/window/partitions (each shutter arean. exc 5sqm) after carrying out ceratin repairs as required, removing the existing beading and fixing new (i.e. included change of Handles, hinges, star lock, rubber beadings, bottom bearing, clips etc) rubber beading of suitable size with adhesive, overhauling of floor springs including repairing/cleaning/ greasing etc and make the same fully functional all as specified and directed. |
| 144 | Taking down and refixing MS window shutters n. exe 1.5 sqm through cutting of existing any type of hinges, handle and tower bolt and fixing new box type hinges, MS handle and MS tower bolt the same window by necessary welding.The quoted rates shall be included the following aspect:-(a) Cutting of existing piano hinges, handle and tower bolt from window frame and shutter.(b) Fixing of removed shutter in the same frame on MS box type hinges 100mm, MS handle 100mm and MS tower bolt 100mm by welding.(c) Easing and adjusting the shutter before re-fixing if required.(d) Finishing the window frame and shutter with two coat of synthetic enamel paint.(e) Necessary scaffolding material to be included as the building height is more than 10mtr.Note :Box type hinges, handle and tower bolt shall be measured separately as supply only and labour element is deemed to be included in this item. |
| 145 | Supply only MS Handle 100mm. |
| 146 | Supply only steel window peg stay all as specified and directed. |
| 147 | Supply only MS Box type hinges 50mm. |
| 148 | Supply only MS tower bolt 75mm |
| 149 | Supply and Fix in repair for 10-12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work including taking down old one of any description complete all as specified and directed. |
| 150 | S & F in repair 18/19 mm thick ,water proof plywood , fixed to Cupboard work in any position with nails including removal of old boards of any description complete all as specified and as directed. |
| 151 | S&F Steel windows with side hung shutters including projecting type hinges, frame with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed. |
| 152 | S&F 4 mm thick sheet glass ordinary quality and glazing complete in square n exc 0.50Sqm in each pane complete all as specified and directed. |
| 153 | Petty repair to aluminium section/glass doors, windows, ventilators, partitions and making good the same size upto 5 Sqm(i.e. including change of Handles, hinges, star lock, rubber beadings, bottom bearing, clips etc) including taking down and refixing complete all as specified and directed. |
| 154 | S&F in repair powder coatedaluminium framewith all fixing arrangementsfor doors, sliding windows andventilators/ partitions etcwith one or more rebates including joining cleat for fixing etc aluminium section of powder coating not less than 50 micron including taking down old one of any description completeall as specified and directed. |
| 155 | S&F in repair Powder coated anodised aluminium windows, and ventilator shutters (thickness of powder coating not less than 50 micron), sliding type without sash bars, aluminium sections weighing 0.55 Kg/m inculding necessary joining cleats glazing clips, rubber packing, anoised aluminium fittings suitable lock with roller complete all as specified and directed. |
| 156 | Supply and fixing in repairs aluminium handles cast type anodised 200 mm long complete all as specified and as directed. |
| 157 | Supply and fixing in repairs 200 mm long aluminium anodized barrel tower bolt extruded section complete all as specified and as directed. |
| 158 | S&F in repairs floor door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor overall 140mm complete including taking down existing oneall as specified and as directed. |
| 159 | S&F Aluminium body door closer hydraulically regulated,designation No.3, universal type, suitable for door shutters of 851 to1000 mm in width and of weight between 61 to 80 kg and fixed including taking down existing one complete all as directed. |
| 160 | Supply and fixing in repair 100mm long Butt hinges medium weight cold rolledstainless steel, fixed in repair to wooden frame/welded to metal frame complete all as specified and as directed. |
| 161 | Supply and Fixing in repairs 250mm Aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extrudud sections or cast- aluminium alloy and fixed complete all as specified and as directed. |
| 162 | S&F in repair looking mirror of size 600mm x 450mm on commerical ply wood 6mm thick with PVC/ wooden moulding beading fixed to wooden plugs with chromium plated brass, screws and cup, washers, aluminium frame and fixed complete all as specified and directed. |
| 163 | S&F PVC beading for cupboard work, colour and pattern as approved including taking down existing one complete all as specified and as directed |
| 164 | S&F Decorative laminates of 0.90 mm thick type matt finish, colour and pattern as approved. including taking down existing one complete all as specified and as directed. |
| 165 | S&F Continuous (piano) hinges, stainless steel bright finish or electrogalvanised of 40mm width of flaps (when open) complete including taking down old all as specified and as directed. |
| 166 | S&F Magnetic catches with 8mm dia steel ball and brass body and striking plate including taking down old complete all as specified and directed. |
| 167 | S & F SS auto closing hinges 35mm length 8 crank bright finish fixed to CB incl screws, plugs etc all as specified and directed |
| 168 | S&F Stainless steel handles of size 100 mm of approved pattern and make suitable for Base/Wall unit of modular kitchen including taking down the existing one complete all as specified and directed. |
| 169 | S&F in repairsstainless steel wire Bottle pull out basket (storagebasket) pull out type, of suitable size 100mm height of grade 304 with necessary fixing clips etc complete all as specified and directed. |
| 170 | S&F in repairs stainless steel wire Thali basket (storagebasket ) pull out type,of suitable size 150mm height of grade 304 with necessary fixing clips etc complete all as specified and directed. |
| 171 | S&F in repairs stainless steel wire saucer basket (storagebasket) pull out type, of suitable size 200mm height of grade 304 with necessary fixing clips etc complete all as specified and directed. |
| 172 | S&F Stainless steel telescopic slider of 500 mm of approved pattern and make suitable fordrawer in base unit of modular kitchen including taking down the existing old one complete all as specified and directed. |
| 173 | S&F Stainless steel handles of size 150 mm of approved pattern and make suitable for Base/Wall unit of modular kitchen Including taking down the existing old one complete. |
| 174 | Supply and fix in repair 40 mm dia cupboard knobs brass polished, complete all as specified and directed. |
| 175 | S&F Plate rack of size 65 cm x 96 cm heavy duty made of stainless steel fixed in repairs complete all as specified and directed. |
| 176 | M&L for 18-20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills,cooking platforms, shelves in cupboard,handwash places and like including necessary cutting and grooving to wallsand making good by pointing in cement mortar (1:2) using admixture of pigment to match with shade of graniteover andincluding cement screedbed Cement Mortar (1:6) 15 mm thickcolourof granite as approved incl removal of old flooring of any description all as specified and directed.NOTE : (i)Dismantling of oldstone slab and tiles etc laid, bedded and pointed in any mortar of any discription of thickness in floor(ii)The unit rate is deemed to be included for rounding to edges of stone slabs. |
| 177 | M&L in Repair of leakage/seepage from the Nahani trap/ floor trap of kitchen/ bathroom/ washbasin of the upper Qtr, in any position at any height, complete including change of floor trap, PVC horizontal pipe embeded in floor in bathroom or kitchen making good to the damaged portion of flooring, laying and matching of tiles in the existing flooring, complete all as specified and directed. |
| 178 | M&L in Repair of leakage/seepage from the wall/ door bend /door tee/\"Y\" junction/ \"T\" Junction of soil pipe / waste pipe/ vent pipe of kitchen/ bathroom/WC of the upper Qtr or at the ground floor Qtr including change of any damaged soil waste pipes or fittings of any shape, specification and size, making good to the damaged portion of wall with brick work in cement mortar 1:6 or cement concrete 1:2:4 and plastering to wall in CM 1:4 and finished the surfaces matching to existing wall complete to avoid the leakage/ seepage at the site of work as directed and as specified. |
| 179 | Note for item No 177 & 178 :- (a)Find out main cause of leakage and take necessary steps to resolve / rectify.(b)Replace existing tiles in case leakage through NT/FT.(c)The rate also include for provision of new NT/FT.(d)The unit rate is also deemed to be included for reqd bonding chemicals to arrest the leakage/seepage as directed by the manufacturer\"s specification. Make : M/s Sika Chemical, M/s Pidilite, M/s Dr Fixit |
| 180 | Material and labourfor taking down of ceiling fan of size 1200/1400mmsweep for safety checking by replacingdefective parts/painting/rewinding and re-fixing the ceiling fan after repairs, all as specified and as directed by Engr-in-charge. (Note:- The replacement of unserviceable items like capacitor, Bearings, Bush, Canopy, down rod etc. shall be made as directed which will be measured and paid separately under respective items as Supply only. However,parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional andmaking connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) including cost of labour for above replacement aredeemed to be inclusive in quoted rate all as directed. |
| 181 | Note:- The following items shall be deemed to be inclusive in the unit rate quoted against Sl Item No 180(a) In each job, checking the functioning of fan including its connections, cleaning of fan, greasing of fan and mechanical check i.e. tightening of loose screw, nuts, bolts, etc are inclusive in unit quoted rate. |
| 182 | (b)The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced to the Engr-in- Charge, before commencement of work. |
| 183 | (c)Replacement of unserviceable parts like rubber bush, clamps, bolts, nuts, washers, safety pin, bearing etc shall be paid under respective item here-in-after as supply only through proper documentation. |
| 184 | (d)The entire job shall be carried out inAir Force stn Jalahalli |
| 185 | (e)Necessary T&P such as ladder, required manpower for taking down and refixing after repair shall be of contractor\"s responsibility. |
| 186 | (f)All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any extra cost to the department. |
| 187 | (g)Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing. |
| 188 | (j)In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered. |
| 189 | (k) In case of minor defects, entire job shall be completed within12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered. |
| 190 | Supply onlyfan bearing suitable forceiling fan 1200mm /1400 mm sweep (bearing with 8 balls shall be used ) Make:- NBC/TATA/SKF |
| 191 | Supply onlygun metalbush of suitable size for ceiling fan 1200mm /1400 mm sweep complete all as specified and directed. |
| 192 | Supply only fan canopies for ceiling fan size of 1200mm/1400mm sweep complete all as specified and directed. |
| 193 | Supply only rotor of ceiling fan of any size complete all as specified and directed. |
| 194 | Supply onlydown rod for ceiling fan with 15mm dia (of length not less than 45cm and not more than 60cm) with hanging clamps for ceiling fan complete all as specified and directed. |
| 195 | Supply only Rubber reel bushes for ceiling fan of size 1200/1400mm sweep complete all as specified and directed. |
| 196 | Supply onlyouter body of ceiling fan of any size complete all as specified and directed. |
| 197 | Supply only steel screw (for fixing of fan blade) as per site requirement for any make of ceiling fan complete all as specified and directed. |
| 198 | Supply only \"U\" clamp for hanging ceiling fan with all nuts, bolts and washers complete all as specified and directed. |
| 199 | Supply onlydown rod for ceiling fan with 15mm dia (of length not less than 180cm and not more than 210cm) with hanging clamps for ceiling fan complete all as specified and directed. |
| 200 | Supply onlyblades (made of aluminium) suitable for 1200/1400mm sweep ceiling fan of any make with set of screws complete all as specifiedand directed . |
| 201 | Supply onlydown rod for ceiling fan with 15mm dia (of length not less than 90cm and not more than 120cm) with hanging clamps for ceiling fan complete all as specified and directed. |
| 202 | Supply only safety cotter pins 40mm to 50mm longwith nuts and bolt with washers for ceiling fan of size 1200/1400mm sweep complete all as specified and directed. |
| 203 | Supply and fixing in replacement of unserviceableCeiling fan 1200mm sweep, energy efficient ISI marked withstar rating 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt andflexible copper cable 3 core of size 1.5 sqmm not less than 0.5 m long complete including taking down existing one, writing MES No. with synthetic enamel paint complete all as specified and directed. Make : Havells/ Bajaj/ OrientNote:-(a)Old Unserviceable ceiling fan shall be deposited to MES store yard by the contractor. |
| 204 | Taking down ofexhaust fan any size/capacity after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling including replacement of parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional andmaking connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) aredeemed to be inclusive in quoted rate all as specified and as directed. Note:- (a)Rewinding, and materials to be replaced are measured separately.) |
| 205 | (b)The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced to Engr-in-Charge before commencement of work. |
| 206 | (c)Defective unserviceable part like fan bush,bearing etc. will be paid under respective item here-in-after as supply only through proper documentation. |
| 207 | (d)The entire job will be carried out inAir Force stn Jalahalli |
| 208 | (e) Necessary T&P such as ladder, helper shall be contractor responsibility. |
| 209 | (f)All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any extra cost to the department. |
| 210 | (g)Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing. |
| 211 | (j)In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered. |
| 212 | (k) In case of minor defects, entire job shall be completed with 12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered. |
| 213 | Supply only 3.15 mfd capacity exhaust fan condenser complete all as specified and directed. |
| 214 | Supply only fan bush of suitable size for exhaust fan of the any sweep complete all as specified and directed. |
| 215 | Supply only metal louvers of suitable size for exhaust fan of the 250mmsweep complete all as specified and directed. |
| 216 | Supply only fan bearing of suitable size for exhaust fan of 250mmsweepincluding greasing complete all as specified and directed. |
| 217 | Supply only fan bearing of suitable size for exhaust fan of 300mmsweepincluding greasing complete all as specified and directed. |
| 218 | Supply only 4 mfd capacity ceiling /exhaust fan condensers complete all as specified and directed complete all as specified and directed. |
| 219 | Supply only 2.5 mfd capacity ceiling /exhaust fan condensers complete all as specified and directed. |
| 220 | Supply only metal louvers of suitable size for exhaust fan of the 300 mmsweep complete all as specified and directed. |
| 221 | Supply only metal louvers of suitable size for exhaust fan of the 450 mmsweep complete all as specified and directed. |
| 222 | Supply only fan bearing of suitable size for exhaust fan of 450mmsweepincluding greasing complete all as specified and directed. |
| 223 | M&L for cutting of hole through stone wall with the help of Core cutting machineincluding providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed. |
| 224 | Supply and fixingExhaust fan250 mm sweep 230/ 240 volt AC single phase PVC body1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells /bajaj/ Crompton Greaves.Note:-Old Unserviceable Exhaust fan shall be deposited to MES store yard. |
| 225 | Material and labour for winding of Exhaust fan 250mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i)Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. |
| 226 | M&L in repairfor stainless steel wire cloth 0.63 mm dia of wire and average width of aperture 1:40 mm for covering of exhaust fan hole in wall of size 450 mm X450 mm with PVC/woodenbeading fixed on wall including necessary fixing arrangement up to hight 11 mtrcomplete all as specified and directed.Note : All safety measures is the responsible of the contractor |
| 227 | Supply and fixingExhaust fan 300 mm sweep 230/ 240 volt AC single phase PVC body 1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells /bajaj/ Crompton Greaves.Note:-Old Unserviceable Exhaust fan shall be deposited to MES store yard. |
| 228 | Material and labour for winding of Exhaust fan 300mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i)Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. |
| 229 | M&L for cutting of hole through brick wall with the help of Core cutting machineincluding providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed. |
| 230 | Supply and fixingExhaust Fan 300 mm sweep, 230/240 volt AC single phase, heavy duty,1400 RPM, corrosion less mild steel body of motor, suitable hold fast with necessary nut, bolts / screws with louver including taking down existing one,writing MES No. with synthetic enamel paint all specified and directed. Make- Havells /Bajaj/ Almonard.Note:-Old Unserviceable domestic exhaust fan shall be deposited to MES store yard. |
| 231 | M&L for repair louver made of galvanised steel suitable for 300 mm size exhaust fan, fixed on wall including necessary fixing arrengement up to height 11 mtrcomplete all as specified and directed.Note : All safety measures shall be the responsible of the contractor. |
| 232 | Material and labour for winding of Exhaust fan 450mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i)Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. |
| 233 | M&L for Sub main wiring with PVC insulated unsheathedFRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 4 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.Note: (a)2 runs of 4 Sqmm cable along with onerun of 4 Sqmm cable for earth conductor shall be measured as one length.Make:- Havells/ Polycab/ Plaza. |
| 234 | S&F in replacementfactory madepowder coated distribution board VTPN, 6 way double doorMCCB DB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as directedMake : Indoasian/ Havells/ Legrand. |
| 235 | S&F in replacement distribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KAconforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 236 | S&F in replacementfactory madepowder coated distribution board TPN, 4 way double doorMCBDB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as directedMake : Indoasian/ Havells/ Legrand. |
| 237 | S & F in replacement TPN, MCB63 Amp, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996, all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 238 | Taking down aluminium/copper point wiring & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete and making good the disturbed plaster surfaces of wall, floor, ceilingand painting 2 coat of white wash/distamber to match the existing surface, complete all as specified and directed. |
| 239 | M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including concealedrigid non mettalic PVC conduit/casing caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes, concealed in wall/surface/roofs/floor/ceiling etc as per site requirement and making & maching the existing surface ) white bakelite sheet cover for mounting switches, Sockets, Fan regulators etc or modular cover plate with frame including sunken boxes suitableto fix modular cover plate with frame , concealed in wall or 1.5 sq mm multi stranded copper conductor cable as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following :- Make of wire: Polycab/Plaza/HavellsNote:Blanking plate,Modular cover plate ,Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely). |
| 240 | All as per item No. 239 here in before but for one light point/fan point controlled by one wayswitch. |
| 241 | All as per item No. 239here in before but for one light point controlled by twowayswitch. |
| 242 | All as per item No. 239here in before but for one bell point controlled by one bell push. |
| 243 | All as per item No. 239 here in before but for one 3 pin socket out 5 Ampon the same board |
| 244 | All as per item No. 239 here in before but for one switch socket outlet 3 pin 5 Amps on independent board |
| 245 | All as per Sl No 239 above but Wiring with 4 Sqmm copper multistranded unsheathed FRLS cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently complete all as specified and directed. |
| 246 | Supply and Fix switch piano flush type 5 Amps240 volts single pole one way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 247 | Supply and Fix switch piano flush type 5 Amps240 volts single pole two way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 248 | Supply and Fix switch piano flush type 5 Amps240 volts bell push, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 249 | Supply and Fix shuttered socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 250 | Supply and Fix shuttered switch socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 251 | Supply and Fix shuttered socket outlet 2 in 1, 3 pin, 5 and 15 Amps, complete all as specified and directed.Make : Anchor/Havells/L&T/Indoasian |
| 252 | S & F in repairs 3.0 mm thick hylum sheetof size 4\"x 4\" forfixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete all as specified and directed. |
| 253 | S & F in repairs 3.0 mm thick hylum sheetof size 6\"x 8\" forfixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete all as specified and directed. |
| 254 | S & F in repairs Modular flush metal box 4 module in the existing wall for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with screws complete all as specified and directed. Note : Concealed the Modular flush metal box on wall all including making good and matching with existing surface included in the quoted rate. |
| 255 | S & F in repairs Modular flush metal box 6 module in the existing wall for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with screws complete all as specified and directed. Note : Concealed the Modular flush metal box on wall all including making good and matching with existing surface included in the quoted rate. |
| 256 | S & F in repairs Modular flush metal box 8 module in the existing wall for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with screws complete all as specified and directed. Note : Concealed the Modular flush metal box on wall all including making good and matching with existing surface included in the quoted rate. |
| 257 | Supply and Fixing in repairs of 4 feet surface mounted batten type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability .The luminaire and driver shall be BIS approved, complete all as specified and directed.Make : Philips/ Bajaj / CG/Havells. |
| 258 | Supply and Fixin replacement ofsurface mounted Square/Roundfor LED 18W Watt downlights made of extruded Aluminium housing and high power LED light source withDriver clear diffuser with separate electronic driver with complete accessories all as specified and directed .Make : Philips/ Bajaj/ CG/Havells. |
| 259 | Supply & Fixing in replacement of electronic LED driver 18/20 W suitable for round ceiling light indoor fitting of make Philips/ crompton/ Bajaj, complete all as specified and directed . |
| 260 | S&F as in repair PVC casing capping medium grade of size 25 mm on wall /roofwith help of screw including serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping,completeall as specified and as directed. Make: Polycab/ Modi/ Presto Plast |
| 261 | M&L for Sub main wiring with PVC insulated unsheathedFRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable sizesurface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 4 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.Note: (a)2 runs of 4 Sqmm cable along with onerun of 4 Sqmm cable for earth conductor shall be measured as one length.Make:- Havells/ Polycab/ Plaza. |
| 262 | S&F in replacementfactory madepowder coated distribution board VTPN, 4 way double doorMCCB DB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as directedMake : Indoasian/ Havells/ Legrand. |
| 263 | S&F in replacement on distribution board MCCB four pole, 63 Amp ultimate breaking capacity 16 KA conforming to IEC -61439-1, complete all as specified and directed.Make : Havells/ L&T/ Indoasian |
| 264 | S&F in replacement factory madepowder coated distribution board SPN 12 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 265 | S & F in replacement ofMCB SPN 240 volts 63 Amps \"C\" curve 10 KA breaking capacity including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian |
| 266 | Supply and Fix in repair switch piano flush type 5 Amps240 volts single pole one way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 267 | Supply and Fix in repair shuttered socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 268 | Supply and Fix in repair shuttered switch socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian |
| 269 | Supply and Fix in repair shuttered switch socket outlet 2 in 1, 5 pin, 5 and 15 Amps, complete all as specified and directed.Make : Anchor/Havells/L&T/Indoasian |
| 270 | Supply and Fixing in repairs of 2 feet surface mounted batten type luminaire , lumen output of 1000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability .The luminaire and driver shall be BIS approved, complete all as specified and directed.Make : Philips/ Bajaj / CG/Havells. |
| 271 | Refixingexisting serviceable LED light fitting fixture any capacity and of any type complete with all accessories internally pre-wired and including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size after cleaning all dust etc. completeall as specified and as directed . |
| 272 | Supply and fixing in repair building security/ LED street light fitting 36 Watt, 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal, management in multiple optics complete, with IP 65/66 protection complete all as specified and directed. Make: Philips/Bajaj/CG |
| 273 | Supply and fix GI pipe 32 mm dia, medium grade for mounting bracket, bent to shape 1.5 meter length and fixing arrangement with two Nos ofclamps set, nut, bolts, washers, andincl taking down old unserviceable GI pipe complete all as specified and directed |
| 274 | S&F in repairs 36 W (WW/WH) LED recessed2x2 luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens.Make : Philips/ Bajaj/CG/Havells. |
| 275 | S & F in repairs 3.0 mm thick hylum sheetof size8\"x 8\" forfixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete all as specified and directed. |
| 276 | S & F in repairs 3.0 mm thick hylum sheet of size 8\"x 12\" forfixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete all as specified and directed. |
| 277 | S & F in repairs Modular flush PVC box 4 module in the existing wall for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with screws complete all as specified and directed. |
| 278 | S & F in repairs Modular flush PVC box 6 module in the existing wall for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with screws complete all as specified and directed. |
| 279 | S & F in repairs Modular flush PVC box 8 module in the existing wall for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with screws complete all as specified and directed. |
| 280 | M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn through and including surface PVC conduit/existing concealed conduit/PVC casing-caping ets as per site requirement onwalls / roofs / floors / ceiling etc and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly with all fitting and fixing accessories including sunk in cast iron / pressed steel terminal boxes (duly painted with two coats of anti corrosive paint out side and two coats of aluminium paint inside ) with 3.0 mm thick hylum brand laminated white bakelite sheet cover for mounting switches, sockets, fans regulators etccomplete for the following :-Make of wire: Polycab/Plaza/HavellsNote: (a) Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely). |
| 281 | All as per item No. 280here in before but forOne light point/fan point controlled by one way 5 Amp switch. |
| 282 | All as per item No. 280here in before but forOne light point controlled by two way 5 Amp switch. |
| 283 | All as per item No. 280here in before but for one bell point controlled by one way bel push. |
| 284 | All as per item No. 280here in before but forOne 3 pin socket out let 5 Ampon the same board |
| 285 | All as per item No. 280here in before but for one switch socket outlet 3 pin 5 Amps on independent board |
| 286 | All as per item No. 280here in before but for Wiring with 4 Sqmm copper multistranded unsheathed FRLS cable and4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently complete all as specified and directed. |
| 287 | Supply and Fixmodular switch1 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 288 | Supply and Fixmodular switch2 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian |
| 289 | Supply and Fixmodular switchbell push .1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian |
| 290 | Supply and Fixmodular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 291 | Supply and Fixmodular switch1 way 16 Amp.1 module, complete all as specified and directed. Make :Legrand/ Crabtree/ Anchor /Indoasian |
| 292 | Supply and Fix modular Socket, 16A - 3/5 pin combined 2 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 293 | Supply and fix White cover plate with frame,2/3 module |
| 294 | Supply and fix White cover plate with frame,4 module |
| 295 | Supply and fix White cover plate with frame,8 module |
| 296 | Supply and fix White cover plate with frame,6 module |
| 297 | Supply and fix White cover plate with frame,12 module |
| 298 | S & F ceiling rose surface bakelight two to three terminal complete all as specified and directedMake : Anchor/Havells/L&T |
| 299 | S & Ffan regulator 120W,for ceiling fan complete all as specified and directed Make : Anchor/Havells/L&T |
| 300 | S & F2.5 mfd condensor for ceiling fan, complete all as specified and directed. Make : Epcos/ Asian/ Tyton |
| 301 | S & Felectric bell, AC 230 volt, single pole Ding Dong type complete all as specified and directed. Make :Anchor/Havells/L&T |
| 302 | S & F Modular fan regulator 120W, 2 Module for ceiling fan complete all as specified and directedMake : Legrand/ Crabtree/ Anchor |
| 303 | M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 Sqmm drawn through in and incl suitable size surface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 6 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.Note: (a)2 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one lengthMake:- Havells/ Polycab/ Plaza. |
| 304 | M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 Sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 6 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.Note: (a)2 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one lengthMake:- Havells/ Polycab/ Plaza. |
| 305 | S&F in replacement factory madepowder coated distribution board SPN 8 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBconforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 306 | S & F in replacement ofMCB SPN 240 volts 16 to 40 Amps \"C\" curve 10 KA breaking capacityincluding taking down unserviceable fitting complete all as specified and as directed. Make : Legrand/ L&T/ Indo Asian |
| 307 | Supply & fix in repair decorative surfacemountedultra slim Square/Roundprofile 18 W LED(WW/WH) lighting fixture Square shape with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of18 Watt and includingcosidering material & labour forfixing ceiling hight upto 7.5 Mtr, complete all as per site requirementand directedMake : Philips/ Bajaj / CG/Havells. |
| 308 | S&F in repairs LED bed side light /wall light/study lightenvironmentel friendly energy effcient of capacity3 W warm whiteetc,inbuilt drivercomplete with all accessories internally pre-wired swing type and including connecting up towith twin core twisted flexible copper conductor cable with suitable size complete all as directed . Make : Bajaj/ Philips / Wipro/CG |
| 309 | Supply & Fixing in replacement of electronic LED driver 2/3 W suitable for bed side light fitting as per site requirement complete all as specified and directed . |
| 310 | S&F in replacement factory madepowder coated distribution board SPN 6 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBconforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 311 | S&F in replacement factory madepowder coated distribution board SPN 4 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 312 | S & F in replacement of MCB single pole 240 volts 6 to 40 Amps \"C\" curve 10 KA breaking capacityincluding taking down unserviceable fitting complete all as specified and as directed. Make : Legrand/ L&T/ Indo Asian |
| 313 | S & F in repairs Modular Switch 1 way 6 A, 1 Module complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 314 | S & F in repairs Modular Switch 1 way 16 A, 1 Module complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 315 | S & F in repairs Modular socket 6 A, - 2/3 pin combined 2 module complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 316 | S & F in repairs Modular socket 6/16 A, - 3/5 pin combined 2 module complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 317 | S & F in repairs modular White cover plate with frame, 1 module |
| 318 | S & F in repairs modular White cover plate with frame, 2 module |
| 319 | S & F in repairs modular White cover plate with frame, 3 module |
| 320 | S & F in repairs modular White cover plate with frame, 4 module |
| 321 | S & F in repairs modular White cover plate with frame, 6 module |
| 322 | S & F in repairs modular White cover plate with frame, 8 module |
| 323 | S & F in repairs modular White cover plate with frame, 12 module |
| 324 | S & F in repairs Modular blank plate one modulecomplete all as specified and directed. |
| 325 | S&F in repairs 36 W (WW/WH) LED surface mounted2x2 luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) all as pecified and directedMake : Philips/ Bajaj/CG/Havells. |
| 326 | M&L for Inspection, checking adjustments and minor repairs of storage water heater 25/50 ltr capacity of any type any make vertical/ horizontal type which includes the following :-(a) Inspection, taking out of drain plug & dewatering and re-fixing the same complete all as directed .(b) Checking water tightness of storage tank . (c) Checking stop cocks with outlet/inlet pipe of geysers, pressure reducing valves etc to ensure free movement of water and easy functioning of parts.(d) Inspecting over flow vent pipe connections to ensure water-tightness and proper flow.(e) Checking and correct earth continuity of electrical items.(f)Checking functioning of heating elementand correct setting adjustment of thermostat.(g) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness.(h) Replacement of defective spares shall be measured and paid under relevant items mentioned below separately as supply and fix. |
| 327 | Note : The following deemed to be inclusive in quoted rate :- |
| 328 | The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced to the Engr-in-Charge before commencement of work. |
| 329 | In case of major defects, entire job shall be completed within 15 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered. |
| 330 | In case of minor defects, entire job shall be completed with in 12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered. |
| 331 | The entire job will be carried out in entire area of Air Force stn Jalahalli |
| 332 | All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any extra cost to the department. |
| 333 | Supply and fixingHeating element1.5 KW 230 volts (ISI marked) suitable for 25/50 ltrs geysers any type and any make including taking down old one including washer/ packing suitable complete all as specified and as directed. |
| 334 | Supply and fixingPVC connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 450 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe including taking down existing one complete all as specified and as directed. |
| 335 | Supply and fixingin replacement pressure relieving valve CP brass confirming to relevant IS with washer suitable for 15mm bore GI pipe suitable for 25/50 ltrs geysers complete all as specified and as directed. |
| 336 | Material and labour forCutting and screwing existing steel water tubing 15/20/25 mm bore for addition /alteration required for connections to geysers etc including taking down existing one complete all as specified and directed. |
| 337 | Supply and fixingin replacement thermostat switch range of 30-80 degree celsiussuitablefor geysers of 25/50 ltrs capacity (ISI marked) complete all as specified and as directed. |
| 338 | Supply and fixingin replacement brass non return valves, screwed down, high pressure, screwed both ends for 15mm bore iron pipe or for union, ISI marked, complete all as specified and as directed. |
| 339 | Supply and fixingOuter body of MS sheet not less than 20 gauge suitable for 25 ltr geyser with white synthetic enamelled paint including taking down existing one complete all as specified and as directed. |
| 340 | Material and labour for Grouting 4 Nos of M12 X100mm bolt in stone /brick masonry wall with 1:4 CM suitable for hanging geysers complete all as specified and as directed. |
| 341 | Supply and fixing Indicator lamp for geyser 25/50 ltr capacity ofcolour green & red complete all as specified and as directed. |
| 342 | Supply and fixingHeating element2.0 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity ,any type and any make including taking down old one including washer/ packing suitable complete all as specified and as directed. |
| 343 | Supply and fixingin replacement bottom cover of MS sheet 20 gauge suitable for 25 ltrs capacity geysers and providing a coat of red oxide to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified and as directed. |
| 344 | Material and labourfor painting of outer surface of 50 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No. on the geyser complete all as specified and as directed. |
| 345 | Taking down carefully storage water heater (geyser) 25 ltr capacity of any type, any make from the location by removing the electric & water supply connection and shifted to work shop/MES store yard for repair and re-installation at any location including Supply and fixingin repair of heavy duty pin type fastener 4\" long and making necessary inlet/outlet electric & water supply connection from existing source to geyser complete all as specified and as directed.Note :- Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. |
| 346 | Supply and installwater heater storage type (Geyser) vertical of capacity 25 Ltr, suitable for high pressure up to 8 barpowder coated metal body, temperature indicating dial , glass line coated tank, magnesium anode,efficient long life copper heating element, wattage 2 KW electrically operated, AC 230 Volt, BEE5 Star Rated with complete fittings/partsand accessories for fixing on wall/surfaceall as per site requirement andspecified anddirected Make:- Bajaj / Racold / Havells |
| 347 | Material and labourfor painting of outer surface of 25 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No on the geyser complete all as specified and as directed. |
| 348 | Taking down carefully storage water heater (geyser) 50 ltr capacity of any type, any make from the location by removing the electric & water supply connection and shifted to work shop/MES store yard for repair and re-installation at any location including Supply and fixingin repair of heavy duty pin type fastener 4\" long and making necessary inlet/outlet electric & water supply connection from existing source to geyser complete all as specified and as directed.Note :- Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. |
| 349 | Supply and fixing Stop valves, 15 mm bore fancy type, chromium plated , high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 350 | Supply and fixingin repair 20 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed. |
| 351 | Supply and fixingin repair Chlorinated PVC (CPVC) Gate Valve of size 20 mm dia, (ISI marked) complete all as specified and as directed. |
| 352 | S&F in repair PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 2.5 Sqmm 3 core,complete all as spcified and directed. Make : Havells/ Polycab/ Plaza |
| 353 | Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth for laying of cables up to proper level and laying of pipelines etcinsoft/loose soil, complete all as specified and directed. |
| 354 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed. |
| 355 | Removing surplus excavated material (soil) not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point, complete all as specified and directed. |
| 356 | Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed.Note :- (i)Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment. |
| 357 | Material and labour for well burnt bricks ‘B’ class as mechanicalprotection to under ground cables laying with length of the bricks equal to the width of the trench, complete all as specified and directed. |
| 358 | Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earthwork, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :-The tenderer shall take into consideration for following points while quoting rate for this item andthe unit rate is deemed to be inclusive for :-(i) Earth work and excavation in any type of soil(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick ,complete all as specified and as directed.(iii) Removing excavated material out side MD land.(iv)Laying of any type/any bore of pipe in trenches including taking down existing unserviceable pipe. Supply of pipe shall be measured and paid separately(v)150 mm thickPCC 1:2:4 type B1 using 20mm graded stone aggregate as inroad to make good existing disturbed surfaces. |
| 359 | Supply only of GI pipe light grade for cable protection of size 50 mm bore with fittings, complete all as specified and directed. |
| 360 | Material and labour forBoring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine including supply of HDPE pipes upto 50 mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed. |
| 361 | Material and labour in repair for 4 core 10 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian |
| 362 | Material and labour in repair for 4 core 16 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian |
| 363 | Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for thecable sizefrom 10Sqmmto 16 Sqmm 4 core of underground LT armoured cables.Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted. |
| 364 | Material and labour in repair for 3 ½ core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian |
| 365 | Material and labour in repair formaking straight through joint with suitablejointing kit consisting of water proof adhesivesfor UG cable of size 3.50/ 4 core 16 Sqmm to 25 Sqmm, complete all as specified and directed. |
| 366 | Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for thecable sizefrom 25Sqmmto 35 Sqmm 3.5 core of underground LT armoured cables.Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted. |
| 367 | Supply, installation, testing & commissioning of maintenance free chemicalearthing system comprising of 17mm dia copper bondedrod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducingliquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed..Make : Model HTSP 317 of safeTrode or equivalent in Snaga/ Cubes 6 Global |
| 368 | The quoted rate shall also deemed to be included the following :- (i)Prior toinstallation of maintenance free chemicalearthing, soil resistivity test to be carried out at the location where earthingwork to be donein presence of Engr-in- Charge/JE (E/M),user and the report has tosubmitto Garrison Engineer with recommendation of manufacturer, if required additional interconnection ofearthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testingandsubmission of report with recommendationdeemed to be included in the quoted rate. |
| 369 | (ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors. |
| 370 | (iii) Rateofearth energizer compound of 25 Kg of 02 bags and earthresistance reducingliquid 10 litre per cane for each pit deemed to be included in the quoted rate. |
| 371 | (iv)Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval |
| 372 | (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete. |
| 373 | (vi) Copper strip of size 20 x 3 mm shallbe fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately). |
| 374 | (vii)Testing of earth shall be carriedout in presence ofdepartmental and user representativeand report shall be submitted to Garrison Engineer duly signed by all concerned. |
| 375 | (viii)Earth resistance tester will be provided by the contractor.Tester should be calibrated from authorised company/ lab. |
| 376 | (ix)Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained. |
| 377 | (x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion. |
| 378 | (xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock. |
| 379 | (xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained. |
| 380 | (xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period. |
| 381 | (xiv) The electrode shallcarry manufacturer\"s name . |
| 382 | (xv) The connection clamp shall be permanentlly welded to the copper boundedrodto avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination. |
| 383 | (xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm. |
| 384 | (xvii)Earth work such as auguring andmaking good the surrounding area shall carried out in any type of soil. |
| 385 | (xviii)The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material. |
| 386 | (xix) Sign boardof mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxideZinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge. |
| 387 | M&L in repair Earth pit cover madeof heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mmfor each electrode pit, including taking down old u/s earth pit cover, complete all as specified and directed. |
| 388 | S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing old unserviceable copper strip of any description, complete all as specified anddirected. Note : - All Joints should be joined by Exothermic Welding or Brazing. |
| 389 | Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india. The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one Nopolycarbonate IP 65, 9 W LED translucent bulk head luminaire color lemp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32Amp 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel boardand remove from site reconnecting existing LT UG Cable with new panel board, complete all as specified and directed and comprising of the following:- |
| 390 | (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA- 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 125 Amp, 25 KA- 03 Nos.(c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amp, 10 KA- 01 No.(d) Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 No.(e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set(f) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). |
| 391 | Note :- An amount of Rs 1,49,628.00 on account of credit schedule for schedule \"A\" part II shall be deducted from the total amount of BOQ to arrive at the contract sum. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail