| 1 | Taking down chowkhat or frame with shutters (without taking off shutters from the frame) n. exc. 1.5 Sqm each, complete all as specified and directed. |
| 2 | All as per item No 2.00 here inbefore but exc. 1.5 Sqm and not exc. 4 Sqm, complete all as specified and directed. |
| 3 | S & F of Aluminium window/ventilator (Powder coated ) double leaf /three leaf with anodized aluminium frame sliding/openable including wheel powder coated of section 62.5x37x2.5 mm thick shutter with bottom & middle rail of section 112.5x37x2.5mm and style & top rail of section 83x37x2.5mm thick with centrally locking arrangement with lock rail of rebate including joints cleat fixing of builders hardware fittings necessary and gazing with 5mm thick ordinary plain glass including wire mesh shutter necessary fittings fixuters & aluminium snap beads, complete all as specified and directed. |
| 4 | M&L powder coated anodised aluminium doors (sliding/hanging type) with frame size 101.60X44.45X 2.00 mm thick and shutter aluminium anodised and top rail 47.62X 44.45 X 1.50mm and style 47.5 x 44.5 x1.5 mm , lock rail 83.50X 44.45 X 1.50mm and bottom rail150.00X 44.50 X 2.50mmincl necessary aluminium fittings like aluminium butt hinges 04 Nos , aluminium handles 150mm 02 Nos,aluminium tower bolts 200mm 01No, mortice lock 4 lever MS, hydraulic door closer of suitable capacity 01 No, aluminium door stoper 01 Nos, jointing cleats,glazing cleats,rubber packing , anodised aluminium shape beading, screws etc with panelling in two parts with12mm thick prelaminated partical board in lower panel and 5mm thick tinted glass in upper panels incl all fittings& fixture, complete all as specified and directed. |
| 5 | S & F in repair powder coating anodised alumium glass partition wall with frames size 101.60x44.45x2.0mm thick and shutter alumium anodised and top rail 47.62x44.45x1.50mm and style 47.5x44.5x1.5mm, lock rail 83.5x44.45x1.50mm and bottom rail 150x44.50x2.50mm with 5.5mm thick plain glass including necessary fitting and fixture, complete all as specified and directed. |
| 6 | S&F in repair Brass chromium plated shower rose with swivel joints with shower arm 15mm size,195mm long, complete all as specified and directed. |
| 7 | Supply and fix in repair vitreous china wall hung wash hand basin with pedestal snow white miniumum size630mmx450mm including chromium plated brass coupling, bottle trap, chromium plated brass centre hole basin mixer, 450 mm PVC reinforced connection (two numbers), angular stop cockvalve) (two numbers), complete all as specified in particular specifications. |
| 8 | S&F in 15 mm bore bib taps, with wall flange long body, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed downscrewed for iron pipe or for brass furrel complete as in repairs all as specified and directed. |
| 9 | S&F in repair Chromium plated stainless steel (Grade S-304)(heavy) grating minimum 3 mm thick of size 125mm dia for trap, complete all as specified and directed. |
| 10 | S & F in chromium plated stainless steel towel rail with lower hanger with hooks fixed to wall with chromium plated brass screws 600mm long between flanges, complete all as specified and directed. |
| 11 | S&F in repair5 mm thickbevelled edge looking mirror of selected quality glass mounted with stainless steelstuds, complete all as specifiesd andas directed. |
| 12 | S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 120mm (minimum) wide with chromium plated brass bracket guard and railing 600mm long, complete all as specified and directed. |
| 13 | S&F in repair Chromium plated brass soap dish (oval shape) to walls (size not less than 125mm long), complete all as specified and directed. |
| 14 | S&F in repair Brass chromium plated mist wall mixer (hot and cold) 15mm bore non telephonic fixed to wall for bathroom, complete all as specified and directed. |
| 15 | Supply and fix in repair 5mm thick glass (selected quality) corner self size 250 mm wide rounded with stainless steel brackets (2 Nos), complete all as specified and directed.Note : Edges of glass shall be grounded/bevelled. |
| 16 | Supply and fix in repair kitchen plate rack made out 0.63mm thick stainless steel (Grade S-304) sheet, SS screwsround pipe of minimum size 600mm x900mmx250mm including fixing with rawal plug and screws, complete all as specified and directed. |
| 17 | Supply and fix in repair stainless steel kitchen sink with drainage board made of 1.00mm (minimum) thick stainless steel (Grade S-304) sheet with plug washer including bedding in cement mortar to wall or including fixing on RCC platform connecting union to pipe overall (minimum ) size 915mm x 460mm with bowl (minimum) size 410mmx330mmx160mm complete including waste coupling CP, 15 mm bore, sink mixer wall mounted with 150mm long swivel spout connecting legs & wall flanges, and waste pipe,all as specified in particular specifications. |
| 18 | 18mm thick celuka PVC sheet minimum 600 Kgbm density grade 1 quality of both side plain white colour rigidlam glossy finish fixed with screws, solvent cement/adhesive as per manufacturer instructions to make kitchen/Cupboard cabinet sides top and bottom and shelves inside the cabinet, complete as per specifications and as directed by the Engineer-in-Charge.Note:- (i) Cupboard accessories i.e. fittings,handles,hinges, will be measured and paid for seperately as supply only under respective of this schedule.(ii) Quoted rates deem to be include fixing of cabinet on wall with appropriate rawl plug/ dash through fastener (hammer type).(iii) Fabrication and installation of cabinet to be carried out by authorised vendor of manufacturer only. |
| 19 | 18mm thick celuka PVC sheet minimum 600 Kg/Cum density grade 1 quality one side pre-laminated and other side plain white colour to make kitchen cabinet/drawer shutters fixed with screws, solvent cement/adhesive as per manufacturer instructions, complete as per specifications and as directed by the Engineer-in-Charge.Note:- (i) Handles,hinges, will be measured and paid for seperately as supply only under respective of this schedule.(ii) Quoted rates deem to be include fixing of cabinet on wall with appropriate rawl plug/ dash through fastener (hammer type).(iii) Colour and design of prelaminated portionshall be as approved by GE.(iv) Fabrication and installation of cabinet to be carried out by authorised vendor of manufacturer only. |
| 20 | 12mm thick celuka PVC sheet minimum 600 Kg./Cum density grade 1 quality of one side plain white colour rigidlam glossy finish fixed with screws, solvent cement/adhesive as per manufacturer instructions to make kitchen cabinet back, completeas per specifications and as directed by the Engineer-in-Charge.Note:- (i) Modular kitchen accessories i.e. basket, cutlery baskets, fittings,handles,hinges, will be measured and paid for seperately as supply only under respective of this schedule.(ii) Quoted rates deem to be include fixing of cabinet on wall with appropriate rawl plug/ dash through fastener (hammer type).(iii) Fabrication and installation of cabinet to be carried out by authorised vendor of manufacturer only. |
| 21 | Supply only autoclosing hydrolic (soft closing) chrome finish stainless steel frog hinge openable at 110 degree, complete all as specified and directed. |
| 22 | Supply only 100mm long stainless steel (grade S-304) handle fancy type polished bright chrome finish, complete all as specified and directed. |
| 23 | Supply only 200mm long stainless steel (grade S-304) handle fancy type polished bright chrome finish, complete all as specified and directed. |
| 24 | Supply and fixed in repair One piece Vitreous china wash down water closet (Pedestal Pattern) size 645mmx35mmx730mm \"white\" with soft close seat cover & twin flush fittings, toilet paper holder, health faucet, PVC connection, angular stop cock (valve) (2 Nos) with flange etc., complete all as specified in Particular specifications. |
| 25 | Demolition & breaking AC drain pipes (salt glzed ware, AC,PVC) set in cement mortar,dia of pipe 100 mm, complete all as specified and directed. |
| 26 | S & F of 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls, complete all as specified and directed. |
| 27 | S & F of 110 mm dia(SWR) pipes single socketed, in any length with rubber ring joints fixed to walls, complete all as specified and directed. |
| 28 | S & F in 75 mm bore PVC (SWR) bends any radius, complete all as specified and directed. |
| 29 | S & F in 110 mm bore PVC (SWR) bends any radius, complete all as specified and directed. |
| 30 | Taking up or down 15 mm dia steel tubing and connections including cleaning for refixing or removal to store, complete all as specified and directed. |
| 31 | Taking up or down 20 mm dia steel tubing and connections including cleaning for refixing or removal to store, complete all as specified and directed. |
| 32 | Supply and fixing of 15 mm bore galvanised steel water tubing \"medium grade\" with all fittings and fixed to walls, ceiling or laid in floors etc., complete all as specified and directed. |
| 33 | Supply and fixing of 20 mm bore galvanised steel water tubing \"medium grade\" with all fittings and fixed to walls, ceiling or laid in floors etc., complete all as specified and directed. |
| 34 | M&L for cutting chases brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends and making good cutting not exceeding 10 cm girthfor concealed water tubing or concealed conduit wiring, etc., complete all as specified and directed. |
| 35 | S & F in drapery rod 25 mm dia with PVC pipe over MS conduit including curtain rings suitable for 25 mm dia pipe& side cups with brackets including fixing arrangements with drilling holes etc., complete of approved quality and colour, complete all as specified anddirected. |
| 36 | M&L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work con- forming to Fe.290. Gde-E-165, complete all as specified anddirected. |
| 37 | Disconnecting existing tanks of capacity exc 250 & n.exc 500 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required, reconnecting and re-fixing in position after cleaning andrepairing etc including cleaning, complete all as specifiedand directed. |
| 38 | S & F in repairs 500 litres capacity rotational moulded polyethylene water storage tanks triple layer,white colour (Cylindrical vertical with closed top) hoisted and fixed in position including dismantling all as specified in SSR Part I, complete all as specified anddirected. |
| 39 | S&F in flush shutters 30mm thick, solid core construction, with block board core & plywood face panels, commercial type on both sides, complete all as specified and directed. |
| 40 | S & F in 35 mm thick of first class hardwood Glazed and skeleton shutters, open rebated and prepare to receive glass, gauge, etc., (with sash bars) size of members of shutters as specified in SSR part-I section 8 clause 8.20 (a) supplied and fitted to chowkats complete all as specified and directed. |
| 41 | S & Fin 125 x 60 mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed. |
| 42 | S&F in MS flat iron as in hold fast etc and similar work incuding making shape, drilling holes etc, confriming to FE 290 Ged E-165, complete all as specified anddirected. |
| 43 | M&L for PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in bed plate for fixing holdfast etc., complete all as specified anddirected. |
| 44 | S&F in repairs Aluminium alloy wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.40mm and fixed with beading to wooden frames as in repairs all as specified and as directed. |
| 45 | Aluminium anodised barrel tower bolts of extruded section of length of bolt 200mm, complete all as specified anddirected. |
| 46 | S&F in Aluminium handles, cast type, anodised of size 100mm, complete all as specified anddirected. |
| 47 | S&F in 300 mm length aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed of length of bolt 300mm, complete all as specified anddirected. |
| 48 | Demolition of brickwork or stone boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified anddirected. |
| 49 | M & L for Brickwork with subclass \"B\" bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified and as directed. |
| 50 | Taking down cement plaster on brick or stone walls, etc, incl raking out joints, hacking for key, scrubbing down with water, etc & prepare to receive new plaster complete all as specified and directed. |
| 51 | M&L for rendering 5mm thick in CM 1:3 finishedin ceiling, complete all as specified and directed. |
| 52 | M&L for 15mm thick rendering in CM 1:6 on fair faces of brick work, surfaces finished even and fair without using extra cement, complete all as specified and directed. |
| 53 | M&L for 15mm thick rendering in CM 1:4 on fair faces of brick work, surfaces finished even and fair without using extra cement, complete all as specified and directed. |
| 54 | M&L for two coat of oil bound distemper on newly plastered surface on wall over 3mm thick wall care putty, complete all as specified anddirected. |
| 55 | Preparation of new plastered surface of ceiling and applying three coats of white wash, complete all as specified anddirected. |
| 56 | M&L for complete removing of existing treatment on wall surface and applyingtwo coat of OBD over 3 mm thick birla white care Putty on wall toobtain smooth finish etc., complete all as specified and directed. |
| 57 | Preparation of old distemper surface and applying one coat oil bound distemper on wall surfaceswhite or tinted, complete all as specified and directed. |
| 58 | All as per item No 57.00 here inbefore but above but one coat of Oil bound distemper on ceiling surface, complete all as specified and directed. |
| 59 | Preparation of old painted surfaces of wood and wood based materials of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enammel paint, complete all as specified and directed. |
| 60 | M&L for preparation of old painted steel surfaces and applying one coat of steel painting, complete all as specified and directed. |
| 61 | M&L for preparation of new steel surfaces and applying two coat of steel paint including primer on steel surfaces, complete all as specified and directed. |
| 62 | M&L for surface of any discription not otherwise describedover 10 cm width or girth on new untreated surface with two coats of synthetic enammelled painting over one coat pink primer on wooden surface, complete all as specified and directed. |
| 63 | M & L for preparation of old decorated surface of wall, roof or sheet any type and applying two coat of ACE exterior emulsion paint (Asian Paint) complete all as specified and directed |
| 64 | Dismantling of floor, hearth or wall tiling includinguding cement mortar bedding but not backing and rubbish off the premises, complete all as specified and directed. |
| 65 | M&L for glazed ceramic coloured tiles in vertical surfaces of size 450x350x7mm thick set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including rendering 10 mm thick in cement mortor (1:4) on vertical surface as in backing coat, complete all as specified and directed. |
| 66 | S&F in 300x300 mmx7-8 mm thick coloured ceramic non skid tilesin floor, set & jointed in neat cement slurry and pointed in white or colured cement to match over 15 mm thick screed bed in cement morta 1:6, complete all as specified and directed. |
| 67 | M&L for vitrified ceramic tiles 10mm thick dark shade(square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid in floors set and jointed as per manufacturer\"s instructions Over & including screed bed or bedding layer 15mm thick in CM (1:6), complete all as specified and directed. |
| 68 | M&L for vitrified ceramic tiles 10mm thick dark shade(square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skirting/dados etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid in floors set and jointed as per manufacturer\"s instructions Over & including rendering layer 10 mm thick in CM (1:4), complete all as specified anf directed. |
| 69 | M&L for granite (of any type) 16 to 20mm thick machine cut, bedded and jointed with white cement with admixture of pigmewnt to match the shade of granite stone incld griding and polishing including 15 mm thick screed bed in CM(1:6), complete all as specified and directed. |
| 70 | S&F in rubber bead for wooden door, complete all as specified and directed. |
| 71 | Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thickness (below and above ground level) and removing the unserviceable materials to a distance not exceeding 100m, complete all as specified and directed. |
| 72 | M&L for 75mm thick for PCC 1:3:6 type C-1 as in plinth protection, complete all as specified and directed. |
| 73 | S&F in Ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum weight 210 gms)of bore of pipe 20mm, complete all as specified and as directed. |
| 74 | Taking down carefully aluminium battenpoint, wiring for light/fan/socket/bell or power point including. All fittings i.e. switch, sockets, ceiling rose, regulators, batten holders, etc. Complete and making good disturbed surfaces of wall/floor to match with the surroundings of wall/ceiling/floor etc including taking down old light fittings. Note :- (i)Contractors quoted rate of this item deemed inclusive of unscrewing of the serviceable fittings and fixture as directed and deposit in MES store yard. (ii)Quoted rate also deem to be included cost of cutting chases for taking out concealed conduit and nitch for terminal box. (iii)Decision of GE shall be final and binding in respect of serviceability of fittings/fixture. (iv)Exhaust fan and ceiling fan shall be taken down in under separate item of this schedule. |
| 75 | M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through new PVC concealed conduit mediem grade, ISI markedand including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded modular metal flush box duly make embossed, concealed in walls with suitable modular inner and outer plate for housing switches , socket outlet and fan regulators etc, complete all as specified and as directed for the followings:- Note : Wiring colour code i.e. Red for Phase, black for Neutral and green for earth shall be maintained. The rate included for suitable sunken metal flux box cover plate blank plates etc for placin modulat fittings etc |
| 76 | (a)For one light/fan/bell point controlled by one switch single pole one way, complete all as specified and as directed. |
| 77 | (b) All as per item No 75.01here-in-before butone3 pin 5 amp switch socket out let on independent board, complete all as specified and as directed. |
| 78 | (c) All as per item No 75.01here inbefore but one 3 pin 5 amps socket outlet on the same board with other switch, complete all as specified and as directed. |
| 79 | All as per item No 75.02here-in-before but using 02 Nos. 4.0 sq mm size for main cable and 01 No.4.0 sq mm size as earth conductor for one 16 amp switch socket outlet on independent board, complete all as specified and as directed. |
| 80 | Supply and fix switch modular flush 6A single pole one way ISI marked (One module), complete all as specified and as directed. |
| 81 | Supply and fix switch modular flush type 15/16 Amp single pole one way 240 volt one module ISI marked, complete all as specified and as directed. |
| 82 | Supply and fix modular sockets 6 Amp 2 in 1 2/3 pin combined (Two module), complete all as specified and as directed. |
| 83 | Supply and fix modular sockets 16Amp 2 in 1 3/5pin combined (Two module), complete all as specified and as directed. |
| 84 | Supply and fix ceiling rose surface bakelite 60x25mm three terminal 240 V grade, complete all as specified and directed by Engr- in Charge. |
| 85 | Supply and fix electronic step type fan regulator 240 volt 50 Htz 120 watt (switch/sockets type in shape) modular type, complete all as specified and as directed. |
| 86 | Supply and fix in replacementcalling bell ding dong type 220 volt 50 Htz, complete all as specified and as directed. |
| 87 | Supply and fix white cover plate with frame one module for modular switches & sockets, complete all as specified and as directed. |
| 88 | All as per item No 84.00 here inbefore but two module, complete all as specified and as directed. |
| 89 | All as per item No 84.00 here inbefore but three module, complete all as specified and as directed. |
| 90 | All as per item No 84.00 here inbefore but four module, complete all as specified and as directed. |
| 91 | All as per item No 84.00 here inbefore but six module, complete all as specified and as directed. |
| 92 | All as per item No 84.00 here inbefore but eight module, complete all as specified and as directed. |
| 93 | Supply and fix metal flush box 1/2 module 1.6 mm for mounting switches & sockets, complete all as specified and as directed. |
| 94 | All as per item No 90.00 here inbefore but three module, complete all as specified and as directed. |
| 95 | All as per item No 90.00 here inbefore but four module, complete all as specified and as directed. |
| 96 | All as per item No 90.00 here inbefore but six module, complete all as specified and as directed. |
| 97 | Supply and fix metal flush box 8 module 1.6 mm for mounting switches & sockets, complete all as specified and as directed. |
| 98 | S&F of LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, system lumen efficiency >90 lumen/watt, 6500kandincluding connectingfrom ceiling rose to fitting, complete all as specified and as directed. |
| 99 | S&F of LED batten luminaire surface mounted 2 feet system wattage of 10 watts system lumen efficiency >90 lumen/watt, 6500kand including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. |
| 100 | S&F of surface /ceiling mounted, round LEDdown light fitting 15 watts with die cast aluminium housing and system wattage of 18W,including connecting up with PVC sheathed 3 core 1.5 Sqmmcopper conductor flexible wire fixed, complete all as specified and as directed. |
| 101 | S&F of surface /ceiling mounted, round LEDdown light fitting 8 watts with die cast aluminium housing and system wattage of 18W,including connecting up with PVC sheathed 3 core 1.5 Sqmmcopper conductor flexible wire fixed, complete all as specified and as directed. |
| 102 | Supply and fix of LED 2 X 2 ft backlite surface mounted fitting 36 Wattsnot less than 3200lm with Metallic CRCA powder coated body,complete all as specified and directed by Engr-in-charge. |
| 103 | S & F of bed side lamp LED 3 Watt, all as specified and directed by Engr in Charge. Make Philipis Model No 48042/30/3 and eqvt as per list of makes in particular specification. |
| 104 | M& L for sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 4 sqmm FRLS, 1100 Volts gradecable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 4 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete. Note:- (a) Two runs of 4.0 sqmm cable and one run of 4 Sqmm cable as earth leadwith conduit shall be measured as one unit length for payment.(b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealconduit and making good to match with existing finish. |
| 105 | Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 6 sqmm FRLS, 1100 Volts gradecable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 6 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete. Note:- (a) Two runs of6 sqmm cable and one run of 6 Sqmm cable as earth leadwith conduit shall be measured as one unit length for payment.(b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish. |
| 106 | S & F of sheet metal enclosure with socket and plug top and MCB single pole and neutral enclosure with two Pin and earth plug and socket complete with one single pole MCB, 240 V, 20 Amp., complete all as specified and as directed. |
| 107 | Supply and fix of wall mounted decorativefancy type bedroom light LED type with frosted glass singlemounted on metalic frame with holder including 12 watt LED bulb, complete all as specified and as directed. |
| 108 | Supply and fix in replacement MCB, SP, 6 to 32 Amp rating,230 volt, 10 KA,\"C\" seriesfixed in DBs catered herein before, complete all as specified and as directed. |
| 109 | Supply and fix of MCB, single pole and neutral, 230 volts, 40 to 63 Amp rating, \"C\" series fixed in DBs catered here-in-before, complete all as specified and as directed. |
| 110 | Supply & fix of MCB DB SPN 12 way, double door, IP-43, IK-09, Isolated Neutral Bar and fixed flush to wall and suitable for universal mounting, completeall as specified and directed. |
| 111 | Supply and fixing in repair Exhaust fan300 mm sweep(steel Body), 1250 RPM, non metallic resin body,single phase 240 volts AC 50 Hzincluding louvers andfor fixing of Exhaust fan and copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan, complete all aspecified and directed by Engineer-in-Charge. |
| 112 | S&F of Ventilating Fan250 mm sweep, 1250 RPM, non metallic resin body,single phase 240 volts AC 50 Hzand connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm size and making of holegrountig nut & bolt, complete all as specified and directed by Engr-in-Charge. |
| 113 | S & F of water heater storage type (Geyser) vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe suitable size with adopter for inlet and outlet water connection having adjustable knob for temperature control and inner tank should be glass line coated, complete all as specified of capacity 25 ltrs having element 1.5/2 KW BEE star rating incl taking down old and deposted to MES store yard. |
| 114 | Supply and fix in repair wall mounted fan 400mm size, 230 volts, 50 Hz 1420 RPM with 90 degree oscillation and having speed control by pull cord system complete all as specified and directed. |
| 115 | Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. |