Tender For Construction Of Ntphc Tikat Sankoo Under Sdp- 1 Earth work in excavation by mechanical means (Hydraulic excavator) infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2 All kinds of soil ( 80 %) 3 Ordinary Rock ( 20%) 4 Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20cm in depth, consolidating eachdeposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 5 Dry stone pitching (any thickness)excluding cost of stones. On Horizontal 6 Providing and laying in position specified grade of cement concrete excluding the cost of centering and , shuttering , 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 7 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thickbed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 8 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished 40 mm thick with 20 mm nominal size stone aggregate 9 Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 10 Providing and laying in position machine batched and machine mixed design mixM-25 grade cement concrete for reinforced cement concrete work, using cementcontent as per approved design mix, including pumping of concrete tosite oflaying but excluding the cost of centering, shuttering, finishing andreinforcement, including admixtures in recommended proportions as per IS: 9103to accelerate, retard setting of concrete, improve workability without impairingstrength and durability as per direction of Engineer-in-charge. (Note :- Cementcontent considered in this item is @ 330 kg/cum. Excess/ less cement used as perdesign mix is payable/recoverable separately). Concrete of M25 grade with minimum cement content of 330 kg /cum All works upto plinth level 11 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cementcontent as per approved design mix, including pumping of concrete to site oflaying but excluding the cost of centering, shuttering, finishing andreinforcement, including admixtures in recommended proportions as per IS: 9103to accelerate, retard setting of concrete, improve workability without impairingstrength and durability as per direction of Engineer-in-charge. (Note :- Cementcontent considered in this item is @ 330 kg/cum. Excess/ less cement used as perN design mix is payable/recoverable separately). All works above plinth level upto floor V level 12 Centering and shuttering including strutting, propping etc. and removal of form work for: 13 Foundations, footings, bases of columns etc. for mass concrete. 14 Walls (any thickness) including attached pilasters, buttresses, plinth andstring courses etc 15 Suspended floors, roofs, landings, balconies and access platforms 16 Edges of slabs and breaks in floors and walls Under 20 cm wide 17 Lintel, beams, plinth beams, girders, bressumers and cantilevers. 18 Columns, pillars, piers, abutments, posts and struts 19 Stairs (excluding landings) except spiral staircases 20 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete 21 Providing and Fixing factory made uPVC door frame, made of uPVC exturdedsections, of size 65 mm xplastic brackets and stainless steel screws, reinforcinghinge side vertical of the frames with PVC profileof Size 28 mm x 30 mm havingwall thickness 2 mm (±0.2 mm), including providing & fixing 3 nos of 126mm longstainless steel hinges to the frame, fixing the frame with jamb with requirednumber & size ofanchor dash fastners, all complete as per manufacturersspecification and direction of Engineer-in-charge. 22 Providing and fixing factory made uPVC white colour casement/casement cumfixed glazed windowscomprising of uPVC multi-chambered frame, sash andmullion (where ever required) extruded profilesduly reinforced with 1.60 ± 0.2mm thick galvanized mild steel section made from roll forming processofrequired length (shape & size according to uPVC profile), uPVC extruded glazingbeads of appropriatedimension, EPDM gasket, stainless steel (SS 304 grade)friction hinges, zinc alloy (white powder coated)casement handles, G.I fasteners100 x 8 mm size for fixing frame to finished wall, plastic packers, plasticcaps andnecessary stainless steel screws etc. Profile of frame & sash shall be mitred cutand fusionwelded at all corners, mullion (if required) shall be also fusion weldedincluding drilling of holes for fixinghardwares and drainage of water etc. Afterfixing frame the gap between frame and adjacent finished wallshall be filled withweather proof silicon sealant over backer rod of required size and of approvedquality,all complete as per approved drawing & direction of Engineer-in-Charge.(Single / double glass panes andsilicon sealant shall be paid separately). Variationin profile dimension in higher side shall be acceptedbut no extra payment on thisaccount shall be made. For uPVC frame, sash and mullion extruded profiles minus 5% tolerance indimension i.e. in depth& width of profile shall be acceptable.uPVC profile shouldbe tested by BSI(UK) & SKZ(Germany) @25000 weathering hours 23 Casement cum fixed panel window having both end single casement panel, middle fixed panels and at top completely fixed ventilator with S.S friction hinges (350 x 19 x 1.9) made of (big series) frame 67 x 60 mm , sash 67x 80 mm &mullion 67 x 80 mm all having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 3.00 sqmu pto 5.00 sqm). 24 Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm),made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wallthickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.) 25 Providing and fixing factory made uPVC white colour sliding glazed doorcomprising of uPVC multi-chambered frame with in-built roller track and sashextruded profiles duly reinforced with 1.60 ± 0.2 mmthick galvanized mild steelsection made from roll forming process of required length (shape & sizeaccordingto uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVCextrudedinterlock and uPVC extruded Inline sash adaptor (if required), EPDMgasket, wool pile, zinc alloy (whitepowder coated) handle with key on one side ofextreme panels along with zinc plated mild steel multipoint locking havingtransmission gear with keeps, zinc alloy (white powder coated) cresent lock(ifrequired), stainless steel (SS 304 grade) body with adjustable double nylonrollers (weight bearingcapacity to be 120 kg), G.I fasteners 100 x 8 mm size forfixing frame to finished wall and necessarystainless steel screws etc. Profile offrame & sash shall be mitred cut and fusion welded at all corners,includingdrilling of holes for fixing hardwares and drainage of water etc. After fixing framethe gapbetween frame and adjacent finished wall shall be filled with weatherproof silicon sealent over backerrod of required size and of approved quality, allcomplete as per approved drawing & direction ofEngineer-in-Charge. (Single /double glass panes, wire mesh and silicon sealent shall be paidseparately).Variation in profile dimension in higher side shall be accepted but noextra payment on this account shall be made. 26 Three track three panels sliding door made of (big series) frame 116 x 45 mm &sash 46 x 82 mm bothhaving wall thickness of 2.3 ± 0.2 mm and single glazingbead/ double glazing bead of appropriatedimension. (Area of door above 5.00sqm) 27 Two track two panels sliding door made of (big series) frame 67 x 50 mm & sash46 x 82 mm both havingwall thickness of 2.3 ± 0.2 mm and single glazing bead /double glazing bead of appropriate dimension.(Area of door above 2.00 sqm upto5.00 sqm) 28 Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm). 29 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be pai for separately).2nd Class Kail Wood 30 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)Second class kail wood9.5.5.1 35 mm thick shutters 31 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick :9.7.2.2 Second class Kail wood 32 Applying priming coat:13.50.1With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) 33 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :13.62.1Two or more coats on new work over an under coat of suitable shade withordinary paint of approved brand and manufacture 34 Providing and fixing Door windows Accessories of Approved Barand and manufacture incld. All fixture complete. 35 L-Drop for doors 36 Tower bolt 8 long for doors 37 Handle for Door 38 Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) : 39 Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average) thick cement mortar 1:3 (1 cement:3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing, polishing and curing complete. 40 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm 41 Providing and laying autoclaved aerated cement blocks masonry with 150 mm/230mm/300mm thick AAC blocks in superstructure above plinth level upto floor V level in cement mortar 1:4 (1 Cement : 4 coarse sand ) and curing complete. The rate includes providing and placing in position 2 nos. 6 mm dia M.S bars at every third course of masonry work.Extra for brick work/tile brick/AAC block masonry in superstructure above floor V level for each four floors or part thereof by mechanical means:Incld. all Carriage from source to site complete. 42 12mm Cement plaster on the rough side of single or half brick wall of mix:1 : 6 ( 1 cement : 6 coarse sand) 43 15mm Cement plaster of mix:1 : 6 ( 1 cement : 6 coarse sand) 44 Structural steel work riveted, bolted or welded in built up sections, trusses andframed work, including cutting hoisting ,fixing in position all carriage complete. 45 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 46 Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed withpolymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.63 mm thick with zinc coating not less than 275 gm/m3 47 Providing valleys of 90 cm wide overall in plain G.S. sheet fixed with polymer coated Jor L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete : 1.60 mm thick with zinc coating not less than 350 gm/m3 48 P/F of 12mm thick T&G planks made of imported wood (New zealand pine or equivalent) for roof soffits & Ceiling on wood work in false ceiling, partitions sawn and putup in position in budloo wood (Ceiling Joists). including cost of necessary adhesive & cost of nails etc. with necessary cornice of required size complete job. incl cost of nails / screws all complete as approved by Engineer-in-charge (including cost of all material, leads, lifts and carriages etc upto site of work complete).Soffits 49 Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete 2 mm thick 50 Finishing walls with water proofing cement paint of required shade New work (Two or more coats applied @ 3.84 kg/10 sqm) 51 Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) 52 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. Water thinnable cement primer 53 Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour Two coats 54 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 55 Providing and laying vetrified Glazed Ceramic floor tiles of size 300x300 mm ormore (thicknessto be specified by the manufacturer), of 1st quality conforming toIS : 15622, of approved make,in all colours, shades, except White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick CementMortar 1:4 (1 Cement : 4 Coarsesand), jointing with grey cement slurry @ 3.3 kg/ sqm includingpointing the joints with white cement and matching pigments etc., complete. 56 Providing & laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen & the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. Per sqm of area.(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). 57 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railingn with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement including king posts of required pattern as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered including fixing accessories such as nuts, bolts, fasteners etc.).6.75kg/Rft 58 Carrige of Sand /Stone Agg for an Avg lead of 15km by mt &100Mtr Head load 59 carriage of Stone Agg (Crushed) for an avg lead of 35 km and 100 mtr head load 60 Sanitary Fitting 61 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid. 62 Providingand fixingwater closet squattingpan (Indian typeW.C. pan )with 100mmsandcast IronPorStrap,10litrelowlevelwhiteP.V.C. flushing cistern with manually controlled device(handlelever) conforming to IS:7231,with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : 63 Providing and fixing white vitreous china flat back half stall size580x380x350mm with White P.V.C automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS:2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required:Range of four half stall urinals with 10 liter P.V.C automatic flushing cistern. 64 Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. 65 Providing and fixing 600x450 mm bevelled edge mirror of superior glass (ofapproved quality) complete with 6 mm thick hard board ground fixed to woodencleats with C.P. brass screws and washers complete. 66 Providing and fixing PTMT towel rail complete with brackets fixed to woodencleats with CP brass screws with concealed fittings arrangement of approvedquality and colour. 600mm long towel rail with total length of 645mm, width 78mm and effectiveheight of 88mm, weighing not less than 190gms. 67 Providing and fixing toilet paper holder : C.P. brass 68 Providing and fixing health faucet with concealed fitting arrangement of approved quality and make. 69 Providing and fixing 15mm nominal bore C.P brass bib cock of approved quality confirming to IS:8931 70 Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg. 71 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.(a) 15 mm nominal dia 72 Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 73 Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106gms. 74 Providing and installation of PUF (Puf Insulated Tanks ) with insulation thickness of 50 mm and density 40 kg/cu.m. UV protected with 0.5c Change in stored water after 6 hours in continous 50c or contionously in -20C with capacity of 1000 Ltrs of Approved Brand As per the directions of engineer incharge Complete Job including carriage upto side of work. 75 Providing and fixing PTMT grating of approved quality and colour150 mm nominal size square 100 mm diameter of the inner hinged round grating. 76 Providing and fixing Floor Traps including all fittings required complete job 77 Providing and fixing soil, waste and vent pipes : Prince Type B 78 75 mm dia. 79 100 mm dia. 80 160 mm dia. 81 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. Incld. Tee, elbow , sowket union, complete. 82 15mm nominal outer dia pipes. 83 20mm nominal outer dia pipes. 84 25mm nominal outer dia pipes. 85 32mm nominal outer dia pipes. 86 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 87 15 mm nominal bore 88 20 mm nominal bore 89 25 mm nominal bore 90 32mm nominal outer dia pipes. 91 Providing and fixing uplasticized PVC connection pipe with brass unions 45 cm length 92 15 mm nominal bore 93 20 mm nominal bore 94 25 mm nominal bore 95 Supply installation testing and commissioning of 1.5 HP water pump for lifting of water 96 Supply installation testing and commissioning of water heaters (Gysers) 50 litre capacity ISI marked 97 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required. 18.10.1 White glazed fire clay kitchen sink of size 600x450x250 mm 98 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) :3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand)finished with floating coat of neat cement and making channels in cementconcrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 99 Supply and installation of High Quality self Regulating heat Tracer of specialized Heating solution for winter isination of water pipe line including all accessories complete including supply and installation of circuit control panels with RCBO MCB, THERMOSTAT ()-@DEGC power connector - two way - 6 sqm w.p splice connector ,w.p tee connector,end seal,mounting kit-w.p,jb,g pipe strap4and adhesive tape roll (50mm x 20m)f.g adhesive tape of any approved brand as per the directions of engineer in charge complete job. 100 Supply and fixing of high quality 32 mm thick nitile insulation tube for water pipilines of approved brand 2 size rock wool of apparent dencity 128kg per cum on outer side of the nitrile tube of 50mm thickness including aluminium duct clading aluminium sheet guage thickness .46 mm to .71 mm of approved quality and finished as per direction of enginees incharge ( Nitrile Tube 32 mm > Rock wool 50mm > Aluminium duct clading .46mm - .71mm ) 101 Provinding and fixing PVc conduit25mm dia in slab incld. Tee, metal junction ,boxes ,Fan box bend etc complete 102 Septic Tank 103 Earth work in excavation by mechanical means (Hydraulic excavator) infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 104 All kinds of soil ( 80 %) 105 Ordinary Rock ( 20%) 106 Supply and laying of Soling stone dry stone pitching packed and ramming Excld. Cost of Stone 107 Providing and laying in position specified grade of cement concrete including the cost of centering and , shuttering , All work up to plinth level 1:2:4 (1cement: 2 coarse sand :4 graded stone aggregate (20mm nominal size) 108 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 109 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete 110 Centering and shuttering including strutting, propping etc. and removal of form work for 111 Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc 112 Suspended floors, roofs, landings, balconies and access platforms. 113 Provision for supply and laying of manhole cover heavy duty 114 Carrige of Sand /Stone Agg for an Avg lead of 15km by mt &100Mtr Head load 115 carriage of Stone Agg (Crushed) for an avg lead of 35 km and 100 mtr head load 116 Sockage Pit 117 Earth work in excavation by mechanical means (Hydraulic excavator) infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 118 All kinds of soil ( 80 %) 119 Ordinary Rock ( 20%) 120 Dry random rubble masonry with hard stone in foundation and plinth using quarry stone with bound stone. Incld. Carriage complete 121 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 122 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete 123 Centering and shuttering including strutting, propping etc. and removal of form work for 124 Suspended floors, roofs, landings, balconies and access platforms. 125 Provision for supply and laying of manhole cover heavy duty 126 Carrige of Sand /Stone Agg for an Avg lead of 15km by mt &100Mtr Head load 127 carriage of Stone Agg (Crushed) for an avg lead of 35 km and 100 mtr head load Please Enable Macros to View BoQ information