| 1 | Supply of impeller casing /propeller casing (materialSS-304) 1 to 2.15 cumec pump of static head 9 to 12 meter |
| 2 | Supply of impeller shaft fitted with shaft sleeves forfollowing rating pump (material SS-410)1 to 2.15 cumec pump of static head 9 to 12 meter |
| 3 | Supply of Top shaft fitted with shaft sleeves forfollowing rating pump (material SS-410)1 to 2.15 cumec pump of static head 9 to 12 meter |
| 4 | Supply of intermidiate shaft fitted with shaft sleeves for following rating pump (material SS-410)1 to 2.15 cumec pump of static head 9 to 12 meter |
| 5 | Supply of shaft sleeve (material SS-316)Inner Diameter 50-70 mm |
| 6 | Supply of Rubber bearing (bush) of Material cutlessneoprene rubber without Gun metal/Bronze shellInner Diameter 50-70 mm |
| 7 | Supply of Link Assembely complete set0.57 cumec to 1.7 cumec pump |
| 8 | Supply of Rachet pin for VT pump0.57 cumec to 1.7 cumec pump |
| 9 | supply of Grease Graphite gland packing |
| 10 | Repairing of suction bell with insertion of existing type shell/bush with cutless neoprene rubber bearing as per existing size and shape with proper locking arrangement and Cap ,repairing of Oval holes of flange,repairing of flange, Welding work, Machining, sanding by sand paper, grinding, painting inside and outside with applying inner coat of zinc chromate red oxide primer and than outer coat of synthetic black enamel paint 0.57 cumec to 1.7 cumec pump |
| 11 | Repair of shaft of VT pump by Groove making at bearing points of shaft for making equal depth for welding, Welding at bearing points of shaft, Machining and grinding at bearing points of shaft to bring its original iameter, Bend removal of shaft to bring it prefect straightness, Repair of key way of shaft according to keys and Repair of threads. 0.57 cumec to 1.7 cumec pump |
| 12 | Rebuilding of impeller blades of VT pump with welding, machining and grinding upto original diameter,Balancing of impeller and shape of impeller blades. 0.57 cumec to 1.7 cumec pump |
| 13 | Bearing 29324 E1 |
| 14 | Bearing 6318 C3 |
| 15 | Providing and Fixing of Spring Charging motor forVCB Aux supply 220V AC including makingconnections testing at site |
| 16 | Providing and Fixing of Manual Spring ChargedMechanism for VCB |
| 17 | Supply of Kilo Watt Hour Meter, IS-722 (415 Volt,3 Phase) |
| 18 | Supply of Digital Type Multi Function Meter ,96X96Sq.Mm, Class: 1, 3 Phase |
| 19 | Providing and Fixing of Power Pack for output supply 30V DC ,Input Supply 230V AC, Impulse 500W for existing Panel |
| 20 | Supply of Closing coil for VCB 30V DC |
| 21 | 6.6/7.2 KV 125 Amp HRC fuse For Capacitor Bank |
| 22 | 6.6/7.2 KV 80 Amp HRC fuse For Capacitor Bank |
| 23 | 6.6/7.2 KV 50 Amp HRC fuse For Capacitor Bank |
| 24 | Supply of 6.6/7.2 KV, 50 Hz Bare capacitor unit for existing HT capacitor bank ( As per IS-13925) at site external fuse design, complete with all accessories as per specification and approved make 175 KVAR HT capacitor 3-phase Voltage 6.6/7.2 KV |
| 25 | Providing & Fixing of Street light bracket made out from following size of \" B \" class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .25 mm Dia. |
| 26 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .LED Street Light fixture with Minimum lumen output 11225 lm |
| 27 | P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc.,complete of approved design: 750 (litres capacity.) |
| 28 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall) 15 mm nominal size |
| 29 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it\"s own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. 1.5 Sq. mm X 2Core |
| 30 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. 20 mm |
| 31 | Refilling of fire extinguisher |
| 32 | Re-barring/ Rewinding of the rotor of 6.6 KV Vertical squirrel cage three phase induction HT motor 300 KW |
| 33 | P and F of 11 KV end termination kit (150/185 sq. mm heat shrinking) |
| 34 | Transportation charges for 6.6 KV HT Motor repair/servicing/rewinding from site to workshop and from workshop to site 150 KW-300 KW |
| 35 | Dynamic balancing of rotor of 6.6 HT induction motoras per grade G2.5 150 KW |
| 36 | Dynamic balancing of rotor of 6.6 HT induction motor as per grade G2.5 300 KW |
| 37 | Shaft Metalizing of rotor shaft of 6.6 KV HT induction motor 150 KW |
| 38 | Shaft Metalizing of rotor shaft of 6.6 KV HT induction motor 300 KW |
| 39 | Rewinding of 6.6 KV HT induction Motor stator with Global VPI system , testing of motor at test bench, testing and trial of motor at site. Scrap will be retained by firm and rates are inclusive of scrap generated in rewinding. 150 KW |
| 40 | Rewinding of 6.6 KV HT induction Motor stator with Global VPI system , testing of motor at test bench, testing and trial of motor at site. Scrap will be retained by firm and rates are inclusive of scrap generated in ewinding. 300 KW |
| 41 | Rewinding of single phase/3phase submersible motor including all necessary material and of the same characteristics as original with required size of super enamelled wire \"E\" class insulation material and testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. From7. 5 HP to 10.0 HP |
| 42 | Repairing of submersible pump of with replacement of broken impellers ,diffuser,bush/bearing set , oil seal complete with testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. From7. 5 HP to 10.0 HP |
| 43 | Painting of machinery, including gearing, housing, shafting, Painting of machinery, including gearing, housing, shafting, bearing, pedestals, oil tanks, control cabinets, hoist beams, pipe support, clamps, ladders etc., of hoists and supporting structures, as per IS 14177, for which surface preparation by blast cleaning of class \"B\", primer coat (one coat) of Zinc phosphate paint to give a minimum dry film thickness of 50 ± 5 microns and finish coat (three coats) of aluminium paint or synthetic enamel paint, using airless spray, to provide a dry film thickness of 25 ± 5 microns per coat. Thus, total dry film thickness of all the coats, including primer coat, should not be less than 125 microns. This will include expenses on mobilization and demobilisation of equipments. For maintenance painting, the surface preparation shall be done by appropriate hand and power tool cleaning. Prior to hand and power tool cleaning, any heavy layer of rust should be removed by chipping. Visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylol or white gasoline. After hand and power tool cleaning, the surface should be cleaned of loose dust and debris and / or blast cleaned as laid down in para 7.0 of IS Code14177. After the surface preparation, the primer and finishing coats shall be carried out as provided above for painting etc. completeUp to 1.5m height |
| 44 | Maintenance of centrifugal pump sets and motor including cost of rewinding of motor, material components and accessories required to repair pumpsets, starters etc. of electric panels, deinstallation and re-installation of pump sets complete in all respect for per centrifugal pump set with panel per month, maintenance of history sheet as directed by Engineer-in-charge for centrifugal pump set per month. Operated load of centrifugal pump sets (HP) 6.0 HP to 12.5 HP |
| 45 | Maintenance of centrifugal pump sets and motor including cost of rewinding of motor, material components and accessories required to repair pumpsets, starters etc. of electric panels, deinstallation and re-installation of pump sets complete in all respect for per centrifugal pump set with panel per month, maintenance of history sheet as directed by Engineer-in-charge for centrifugal pump set per month. Operated load of centrifugal pump sets (HP)13.0 HP to 20.0 HP |
| 46 | Maintenance of centrifugal pump sets and motor including cost of rewinding of motor, material components and accessories required to repair pumpsets, starters etc. of electric panels, deinstallation and re-installation of pump sets complete in all respect for per centrifugal pump set with panel per month, maintenance of history sheet as directed by Engineer-in-charge for centrifugal pump set per month. Operated load of centrifugal pump sets (HP)21.0 HP to 30.0 HP |
| 47 | Maintenance of centrifugal pump sets and motor including cost of rewinding of motor, material components and accessories required to repair pumpsets, starters etc. of electric panels, deinstallation and re-installation of pump sets complete in all respect for per centrifugal pump set with panel per month, maintenance of history sheet as directed by Engineer-in-charge for centrifugal pump set per month. Operated load of centrifugal pump sets (HP)41.0 HP to 50.0 HP |
| 48 | Beldar/women Cooli/ Chowkidar/Water man / Earth dresser |
| 49 | Helper for Mason/Mistri/Painter/Carpenter/Electrician/BlackSmith / Plumber / Survey Work/Fitter |
| 50 | Mason/ Painter/ Carpenter/ Electrician-I /Black smith / Plumber |
| 51 | Welder/Fitter/Line-man/Turner/Wireman/Driller |
| 52 | Driver for pumps/Concrete Mixers/ Pumping Station Operator |
| 53 | Work Agents/Surveyors/Supervisors. Civil / Mechnical Engineer Possessing Diploma or equivalent. |
| 54 | Tractor upto 40HP |
| 55 | Tractor Trolly above 2 cum capacity (without staff) with hydraulic lift |
| 56 | Inspection Vehicle such as Jeep |
| 57 | cost of diesel Please Enable Macros to View BoQ information |