Tender For Special Repair To Bldg No. P-12/1 To 08 Of Or Md Accn Of Zone Wksp At Damtal Under Ge South Pathankot; 1 Taking down chowkat or frame with shutter (without taking off shutter from the frame) not exceeding 1.50 Sqm each including taking out hold fast embedded in PCC, complete all as specified and directed. 2 Taking down chowkat or frame with shutter (without taking off shutter from the frame) exceeding 1.5 Sqm and n.exc 4 Sqm each, complete all as specified and directed. 3 S&F pressed steel frame for doors made out of MS sheet 1.25mm thick of size 125mmx60mm for with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. including filling of concrete 1:3:6 type C-1 back of chowkhats complete all as specified and directed. 4 S&F pressed steel frame for door made out of MS sheet 1.25mm thick of size 105mmx60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. including filling of concrete 1:3:6 type C-1 back of chowkats complete all as specified and directed. 5 S&F 35mm thick, 2nd class hard wood plain framed, panelled (factory made) shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated, fitted to chowkats complete all as specified and directed. 6 S&F 35mm thick 2nd class hard wood in glazed and Skelton factory made shutters open rebated and prepared to receive glass/wire gauge etc. with sash bars edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass/wire mesh etc. sizes of members as per clause 8.20(a) of SSR Part-I complete all as specified and directed. 7 S&F floor door stopper of overall length of cover plate 140mm aluminium alloy body and tongue, anodised, with hard drawn steel spring fixed in floor complete all as specified and directed. 8 S&F Factory made Solid PVC Moulded Door Shutterwith wood free EPS, 28 to 30mm thick (stiles) with 5 mm thick moulded prelam PVC sheet on the front face and 5 mm prelam PVC sheet on back face, supplying & fixing in the frame at site as per specification & drawing complete all as specified and directed. 9 S&F 100mm long butt hinges medium weight cold rolled ISI marked mild steel complete all as specified and directed including necessary welding if required . 10 S&F 125mm extruded aluminium alloy handle fabricated anodized ISI marked, complete all as specified and directed. 11 S&F 150mm extruded aluminium alloy handle fabricated anodized ISI marked, complete all as specified and directed. 12 S&F 150mm long aluminium, anodized barrel tower bolts of extruded section ISI marked, complete all as specified and directed. 13 S&F in repair, 300mm, Mild steel spring for door, ordinary rat tail rod pattern springs, including roller and roller plate complete all as specified. 14 S&F for 300 mm long mild steel sliding door bolts, plate type, with stainless steelbright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified and directed. 15 S&F Mild steel framed work such as grills, gratings using square/round bar with ends of bars shoulders/welded drilling holes for fixing of guard bars, complete all as specified and directed. 16 S&F Windows, Ventilators fabricated from roll formed sections made of Galvanized Steel Colour Coated/ Powder Coated (Base Steel as per IS 513 “D” quality, Galvanized as per IS 277 with Zinc of 120 grams/ Sqr. Mtr.) with total coated thickness of 0.60 mmPaint specifications: -Coated Sections should be coated with Primer Coat of Epoxy Primer of 5-7 microns thick, finish painted with Polyester paint of 12-16 microns thick and back coated with Alkyd backer of 5-7 microns, or Powder Coated with pure Polyester Powder up to 50-60 microns thick.Dimensions of Sections: -Sections for Frame should be of 72mm X 50mm, Section for Mullion should be of 72mmX50mm, Section for Shutter Frame should be of 47mm X 20mm, Section for Fixed Glass Bead should be of 12mmX12mm, and Section for Fly mesh should be of 40mm X 20mm.Fixing Details:-Section for Frame Glazed Shutters and Mesh Shutters should be cut to length and miter joined with Polypropylene Corner Brackets, Mullion Section should be joined to the Frame/ Mullion using Nylon cap. Ethyl Propylene Diamine Monomer (EPDM) Gasket should be used all around glass in shutter and Fixed Glass. Spoon profile should be used around Fly mesh to fix Mesh in Mesh Shutter.Accessories:-Each Glazed Shutter should be provided with S.S. Pivot Hinges-1set, Seccolor Handle & Seccolor Stay.Window frame should be fix to brick/concrete masonary by using Nylon-self expanding caps & driving MS electroplated 80mm long screws into the caps through frame.Glass:- Glass shutter & fixed glass portions should be provieded with a glass of 5mm plain float glass.Mesh:- Mesh shutter should be provided with a stainless steel 32 Gauge fly mesh of 304 grades with 144 holes per square inch.Grill:- Window should be provided with grill made of 10 mm Sq MS bars welded to at 150 mm centre to centre, 6mm x 12mm MS flat. Total grill unit should be powder coated and fixed to window frame with screws. 17 S&F galvanized mild steel wire cloths 0.56mm nominal dia and average width of aperture 1.18mm & fixed with tint tacks or galvanized wire staples complete all as specified and directed. 18 M&L for two coats of synthetic enamelpaint on new wooden surfaces including preparation of surface and one coat of pink primer all as specified. 19 M&L for Preparation of new painted steel surface of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. 20 Demolition of brick work stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc, complete all as specified and directed. 21 M&L for brick work in cement mortar 1:4 of old size sub class ‘B bricks straight or curved on plan exceeding 6mtr mean radius, complete all as specified and directed. 22 M&L for brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick wallsbuilt in cement mortar 1:4, complete all as specified and directed. 23 M&L rendering 15 mm thick on concrete in CM 1:3 in facia or ediging of chajjas, ceiling and roof projection etc incl taking taking out pealed off plaster/concrete and making good to crackes in RCC surfaces in true line/shape by providing RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate including all necessary from workto thickness at required at GF and FF finish even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge. NOTE - The rate will inclussive of scafolding for single or double story including making holes in brickwork and making good in cement mortor. 24 S&FRotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted fixed in position all as specified in SSR part-I, capacity of tank 1000 ltr incl inlet and outlet connection 20mm dia and 15mm dia GI pipes medium grade respectively, 20mm GI pipe medium grade over flow pipe 15cm long and PTMT valve 20mm high pressure with polyethylene float and fly nuts including dismantling water tanks (capacity of tank exc. 500 ltr but n. exc. 1000 ltr) and removing from site complete all as specified and directed. 25 M&L in repair 20mm dia Gun metal globe or gate walve with iron wheeled head, screwed both ends for iron and fixed in repairs complete all as specified and directed. 26 S&F PVC (SWR) pipes single sockets in any length with rubber ring joints fixed to walls with clamps as arain water pipes, 110mm bore with cement joints complete all as specified and directed. 27 Description all as per per item No. 26 here-in-above but laid in floor/trenches 28 S&F PVC (SWR) bends of 110mm bore any radius complete all as specified and directed. 29 Taking down old eaves gutters and rainwater pipes (any size or pattern) , including all fitting ,head ,shoes ,bend, swan-nacks etc., including cleaning or refixing or removal to store . 30 Taking down cement plaster on brick or concrete surfacesany description including raking out joints hacking for key scrubbing down with water complete all as specified and directed. 31 M&L for Rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finishing the surfaces even and smooth without using extra cement and curing the surface, complete all as specified and directed. 32 S&F of UPVC underground drawings pipe (UDS) type B160mm dia with wall thickness 4mm (min) and pressured 4 KN /Mtr Sq jointed in cement solvent completeincluding providing 100 mm thick cement concrete (1:4:8) type D-2 using 40mm graded crushed stone agg as in bed for 160mm bore pipes incl packing under and huaunching against the sides of pipes after they are laid tested including Taking down old damaged SGSW pipes from existing lines including necessary excavation of old fitted in trenches complete all as specified and directed . 33 M & L cutting into existing manholes for connecting new drains/ pipe of any dia, making good to pipe and making good of broken manhole. 34 M&L for Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finishing the surfaces even & smooth without using extra cement including scaffolding for single or double storey and curing the surface, complete all as specified and directed. 35 M&L for Rendering 5mm thick in cement mortar 1:3 on fair faces of brick work or concrete surfaces in ceiling finishing the surface even and smooth without using extra cement complete all as specified.. 36 M&L for preparation of new plastered or unplastered surfaces of ceiling including cornices plasters and applying two coats of oil bound distemper over a coat of primer on ceiling, complete all as specified and directed. 37 M&L for preparation of old plastered or unplastered surfaces of ceiling including cornices plasters by brooming down with steel wire brushing, scrapping down smoke soot moulds, moss and efflorescent salt and trading oil & greasy spots etc and applying two coats of oil bound distemper on ceiling, complete all as specified and directed. 38 M&L for applying 1mmwall care puttyon walls and make the surface of level, including preparation of new plastered surface of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed. 39 M&L for complete removal of existing treatment from internalsurfaces of walls by wire brushing and washing, rubbing down and stopping of surfaces , applying 1mmwall care puttyon walls and make the surface of level, clean and repair disturbededgs of bricks/concrete walls finish to even and smooth and applying two coats of oil bound distemper over old surface all as spd and directed by Engr-in-Charge. 40 Material & Labour for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.all as specified and directed 41 Material & Labour for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old plastered surfaces of wall .all as specified and directed 42 S&F in repair 32mm bore corrugated PVC waste pipe, complete all as specified and directed. 43 S&F in repair 38mm bore corrugated PVC waste pipe, complete all as specified and directed. 44 M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (sq/ rect) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, infloor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in cement mortar 1:6 including dismantling of floor tiling incl cement mortar bedding (but not backing)removing serviceable tiles to a store and rubbish off premises complete all as specified and directed. 45 M&L for 25 mm thick PCC 1:2:4 type B-0 (using 12.50 mm graded crushed stone aggregate) as in flooring and surface all as specified and as directed. 46 M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (sq/ rect) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, infloor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in cement mortar 1:6 including dismantling of floor tiling incl cement mortar bedding (but not backing)removing serviceable tiles to a store and rubbish off premises complete all as specified and directed. 47 Description all as per item No. 46 here-in-above but on vertical surface over rendering 10 mm thick in cement mortar 1:4 48 M&L for providing glazed ceramic colouredwall tiles of size 450mmx350mmx7mm thick, set, jointed in colour cement to match laid over and including 10 mm thick rendering in cement mortar 1:4 including dismantling ofwall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to a store and rubbish off premises, complete all as specified and directed. 49 Taking up or down GI pipes 20mm bore and connection including cleaning for refixing or removal un-serviceable pipe from site, complete all as specified and directed. 50 Taking up or down GI pipe 15mm bore and connections, including cleaning for refixing or removal unserviceable pipe from site, complete all as specified and directed. 51 S&F GI tube 20mm bore medium grade galvanized with all fitting and fixed to short length, complete all as specified and directed. 52 All as per description of serial item No. 51 here-in-above but except tubing. 53 S&F 15mm bore GI tubing medium grade galvanized ISI marked with all fittings, laid in trenches or ground in walls, complete all as specified and directed. 54 All as per description of serial item No. 53 here-in-above but except tubing. 55 M&L for water proofing treatment to sunken slab, walls, etc, and shall be carried out as specified below and as directed.(a) Clean the sunken portion of toilet / Baths/ WCs/ Kitchen thoroughly to remove laitance, dirt, dust etc.(b) Form angle fillet of size 40 mm x 40 mm along the junction of wall and floor using polymer modified mortar (“ Dr fixit” Pidicrete URP” or eqvt).(c) Sanitary pipes entering through walls and floor shall be sealed with “Dr Fixit Bath seal Tape” and the gaps to be grouted with non-shrink cementitous grout “Dr Fixit Bath seal Grout” or eqvt. Nahani traps etc to be fitted securely and the gaps around it to be grounted in the same manner.(d) Apply one coat of a Bitumen-modified polymer coating “Dr Fixit Bath seal Plus” or eqvt on all angle fillets by brush and cover it with 100mm open woven mesh when it is still wet. Apply second coat of the same coating on the angle fillets and allow it to dry completely.(e) In the remaining area, in dry substrate condition brush apply first coat of the same coating and further apply second coat when first is dry. Extend the coating upto150mm above the FFL. Above FFL, another cementitious waterproofing waterproof coating “Dr Fixit Pidifin 2 K” or eqvt can be further applied right upto 2.1 m to waterproof the shower area also, if it is a bathroom or bath cubicles of a sanitary annex and apply second coat after 6-8 hours and allow to dry completely.(f) After 2 to 3 days, sunken portion must be overlaid with a 50 mm thick concrete screed 1:3:6 type B0 mixed with integral WPC (Liquid) laid to slope 1:60 towards outer face of wall. Provide 40 mm OD UPVC pipe at the lowest point with 300 mm projection beyond the outer face of the wall. Then fill up the sunken portion with lean concrete 1:5:10 type E2.(g) After completing plumbing work in the toilet/WC/Bath/Kitchen floor, tiling work (floor and dado) can be carried out using suitable Tile Adhesives and ready to make tile grouts of approved makes such as Dr Fixit, FOSROC, SIKA etc. 56 S&F in repair vitreous China squatting pan Orissa pattern size 580 x 440mm white with integral foot rest (excluding flushing cistern and flush pipe), including connection to trap, and to flushing pipe, anty syphonage pipe etc. and including 110mm bore PVC P or S trap complete incl making good to floor complete all as specifed and directed. 57 S&F in repair vitreous china wash hand basin (flat back or angle back type)colouredof bowl size 550mmx400mm including waste coupling and wastepipe PVC 32mm dia to be fixed over marble slabs or mild steel brackets complete all as specified and directed. 58 S&F pillar tap, cast copper alloy, chromium plated, fancy type with capstan heads screwed down high pressure with or without lettered hot or cold with long screwed, shanked and fly nuts screwed for iron pipe 15mm dia complete all as specified and directed. 59 S&F in repair 5mm thick looking mirror of size 600x450mmof selected quality glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs withchromium plated brass screws and cup washers complete all as specified and directed. 60 S&F brass chromium plated tubular towel rail 20mm dia D type 60cm long between flanges, complete all as specified and directed. 61 S&F in repairs 10 liters PVC low level flushing cistern (white colour) syphonic action type with inlet ball valve float and push type handle including bracket, PVC 32mm diaflush pipe with coupling and fixed complete all as specified and directed. 62 S&F in repair sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes pipe and waste coupling including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe,overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. 63 S&F 75mm Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4), complete all as specified and directed. 64 S&F in repair PVC connection 15mm bore size with PTMT nuts of length 450mm complete all as specified and directed. 65 S&FSheet glass corner shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. 66 S&Ffor Cornerglass shelf assembly consisting of 5mm thick sheet glass shelf 30cm wide with chromium plated bracket guard and railing complete all as specified and directed. 67 S&F in repair bib taps, fancy type, chromium plated, cast copper alloy ISI marked with crutch or butter fly handle high pressure screwed down screwed for iron pipe of 15mm bore, complete all as specified and directed. 68 S&F in repair 15mm boreAngle valve fancy type chromium plated ISI marked with crutch or butter fly handle high pressure screwed both ends for iron pipe or for union and fixed complete all as specified and directed. 69 S&F in repair stop valves (ISI marked),15mm dia, cast copper alloy, chromium plated fancy type with long shank and cup(concealed type) screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipes or for unions and fixed in pipe, complete all as specified and directed. 70 S&F in repair Basin mixer tap cast copper alloy chromiun plated with capstan headsscrewed down high pressure or without lettered hot & cold with long screwed, shanked and fly nuts screwed for 15mm bore complete all as specified and as directed 71 S&F grating round 100 mm size of stain less steel as in repair, complete all as specified and directed. 72 S&F in repairshower 100mm fixing with 15mm pipe incl shower arm 15mm size complete all as specified. 73 S&F in repair Sink cock with regular swinging spout. Make Jaguar (cat part No.FLP 5347PM) or equaivalent. 74 S&F PVC (SWR) bends of 75mm bore any radius complete all as specified and directed. 75 M&L 75mm CI Branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed. 76 S&F PVC (SWR) pipes single sockets in any length with rubber ring joints fixed to walls as soil or waste pipes, 110mm bore with cement joints complete all as specified and directed. 77 S&F PVC (SWR) pipes single sockets in any length with rubber ring joints fixed to walls as soil or waste pipe, 75mm bore with cement joints complete all as specified and directed. 78 M&L 75mm PVC Bends (any radius), with oval access door diminishing pieces or tapers (larger bore measured), complete all as specified and directed 79 S&F in repair Stain less steelcurtain rods 25mm dia factoryfixed, complete all as specified and directed. 80 S&F insteel bracketsfor 25 mm dia rod fixed with screws and gutties in wall and fixed to curtain rod with screws of design/shape, complete all as specified and directed. 81 M&L for Jet Black granite18- 20 mm thick Machine cut , pre polished, bedded and jointed with grey cement slurry and pointedwith white cement with admixture of pigment to match the shade of granite stone as in kitchan plateform , flooring including grinding mirror polishing and half moulding laid over 15 mm thick screed bedding in cement mortor 1:6 and all other similar works complete all as specified and directed. 82 S&F in repair 20mm ball valve high pressure with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified. 83 Demolition of cement concrete (unreinforced)in ground floor and paving n.exc 15 cm thicknss (below or above ground level) complete all as specified and directed. 84 Demolition of cement concrete (reinforced)of any description and in any position not otherwise sepecifically provided for complete all as specified and directed. 85 M&L 50mm thick plain cement concrete type C-1 1:3:6 (using 20mm graded crushed stone aggregate) as in flooring/Sub base/Plinth protectionall as spd and directed. 86 M&L 75mm thick plain cement concrete type C-2 1:3:6 (using 20mm graded crushed stone aggregate) as in flooring/Sub base all as specified and directed. 87 M&L for Mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, bending, binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. 88 S&F in repair SS chromium plated, plated peg setfixed with screw complete all as specified and directed. 89 M&L for 40 mm thick brick tiles bedded in cement mortar (1:6), 15mm thickand joints grouted flush in cement mortar (1:3) mixed with 5% of cruded oil by weight of cement including dismantling brick tiles or terracing tiles, single layer on roofs complete all as specified and directed. 90 M&Lfor Non abrasive paving (rectified endura) heavy duty cement concrete coloured tiles 300x300mmx10mm thick set jointed and pointed in neat cement slurry mixed with pigment laid over 15mm thick screed bed in cement mortar 1:4 including demolition/dismantling old surface/tiles complete all as specified and directed. 91 Description all as per item No 90 here in before but on vertical surfaces on 10 mm thick CM 1:4. 92 M&L for PCC padding in roof slabs/chhajjas in PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate with and incl integral waterproofingcompound @ 3% weight of cement and providingnecessary slope towards outside complete all as specified and directed. 93 S&F in repair mild steel, chromium plated Soap Dish fixed with and incl CP screws all as specified and directed. 94 M&L reinforced cement concrete as in shelf (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in cover slabs kitchan platform, shelves and similar articles including necessary moulds/formwork set in cement mortar (1:6) incl demolition of RCC shelf of any description, complete all as specifed and directed. 95 Formwork to soffits of Kitchen cooking platform slabs and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed 96 M&L for liquid water proofing treatment to RCC roof slab incld dismantling of existing treatment of any description in following procedure : (a) Laying 10mm thick rendering in Cement mortar 1:4 mixed with WPC 3% by weight of cement onfair faces of concreteroof surfaces , finished even and fair to receive treatment on roof Complete (b) Applying first coat fiber reinforced elastometic liquid water proofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibers with sun reflective index (SRI) of 100-110, having minimum elongation of 350%, tensile strength 2.9 Mpa and shall have reack bridging ability upto 2.5mm and shall resist 10 bars of hydrostatic pressure reduce surface temperature upto 10 degree celsius with 3.3% dilution as priming coat (c) laying of fiber mesh 0.3mm thickness weave in leno pattern having weight 4.5 gm/ Sqm and pasting it properly with overlap of 50mm and allow it to dry (d) Applying second coat undiluted @ 0.45 ltr/ sqm as directed by Engr-in-Charge (e) Applying third and final coat undiluted @ 0.45 ltr/ sqm as directed by Engr-in-Charge. (The rate includes for filling cracks in existing roof with cement putty using suitable bonding agent (shalcrate 42) before laying cement plaster) 97 S&F prelaminated 18 mm thick lead free factory made 100 % solid WPC (wood polymer composite) sheet having high natural fiber content 25 to 30 % wood colour sheets with densitynot less than 500 Kg/Cum and the weight of sheet of 1 Sqm should be 11 Kg(+- 5%) manufactured by ISO 9001-2015 certified company. The sheet should be 100 % water proof, termite proof ,fire retardant, manufactured by singlelayer extrusion process with excellent screw holding capacityand shore D hardness, complete all as specified and directed. 98 S&F factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other frame/Chowkhat of size 45x70mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum , screw withdrawal strength of 2200N (Face) & 1100N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with properly of being termite/borer proof, water/moisture proof and fire retardant 152 Section 8 and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length, complete all as specified and directed. 99 S&F magnetic door catches with sticking plate of standard size for cupboard/cabinet doors aprooved by GE as specified and directed. 100 S & F continuouspiano hinges (30mm width of flaps when open) mild steel, bright finish complete all as specified and directed 101 S&F 100mm Hasp and staple, safety type, aluminum anodised including bolt to hinge plate and fixed with screws complete 102 M&L for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in coping, benching, PCC, block for hold fast including all necessary from work complete all as specified and directed. 103 Dismantling boarding, any description, fixed in any positionwith nails complete all as specified and directed. 104 S&F Stainless steel plate rack of size (900mm x 750mmx250mm ) made out of AISl 304 stainless steel 0.63 mm thick sheet fixed with screw of required size including necessary fittings/nuts, bolts & washers complete all as specified and directed. 105 Supply and fixing in repairs CP wall mixture, valve cast copper alloy fancy type for mixture hot and cold water screwed down high pressure with capstan head screwed both ends for iron pipe 15mm bore dia complete all as specified and directed. 106 S&F 125mm size stainless steel bright finish handle as approved by GE, fixed with Nut and bolt complete all as specified and directed. 107 S&F of stainless steel 304 grade electro-polished for corrosion resistance modular thali holder /basket having size of 42 x 58.5 x 20 cm including telescopic drawer channel having weighing capacity of 6 kg complete all as specified and directed. 108 S & F of stainless steel 304 grade electro-polished for corrosion resistance modular cup & saucer holder / basket size of 52 x 53.5 x 10 cm with telescopic drawer channel having weighing capacity of 4kg complete all as specified and directed. 109 S & F SS 304 grade 200mm length stainless steel cabinet drawers handlescomplete all as specified and directed. 110 S & F in repairs of stainless steel grain trolley SS 304 grade having size of 525x485x350mm, with heavy duty and grade steelwith finish of zinc, corrosion resistance with telescopic drawer channel having weighing capacity of 25 kgcomplete all as specified and directed. 111 S & F in repairs of stainless steel Plane wire Basket/ trolley SS 304 grade having size of 506x480x200mm, with heavy duty and grade steelwith finish of zinc, corrosion resistance with telescopic drawer channel having weighing capacity of 25 kgcomplete all as specified and directed. 112 S&F stainlesss steel modular perforated cutlery basket SS 304 grade of size 52x48.5x10 cm with telescopic drawer channel having weighing capacity of 6 kg complete all as specified and directed. 113 S&F stainless steel 304 grade Size 180x515x485 mm pull out detergent rack Cat No ASSEDP180510485 having two shelf spaces with telescopic drawer channel having weighing capacity of 6 kg complete all as specified and directed. 114 Supply and laying in replacement of cable XLPE insulated armoured heavy duty electric cable with extruded insulation aluminium counductor, 1100 volts grade of cross sectional area 35 Sqmm 3.5 Core, complete all as specified and directed. 115 Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for laying of cables, pipes etc and getting out in any type of soil complete all as specified and directed. 116 Returning filling in including spreading, leveling and well ramming, in layers not exceeding 25 cm each layer of any type of soil complete all as specified and directed. 117 Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed. 118 M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified and directed. Note: Punned thickness of sand shall be measured. 119 Supply and laying sub class B bricks of old size (230x115x75 mm) or of size locally available ,laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge 120 Material and labour for replacement of GI tubing light grade 50 mm borefor passing through cables under the floor, along the wall or along the pole complete all as specified and directed . 121 S&F GI tubing medium grade Galvanized of size 25 mm bore laid in trenches or ground/ in wall surfaces with and including all fitting complete all as specified and directed. 122 S&F GI tubing medium grade Galvanized of size 40 mm bore laid in trenches or ground/ in wall surfaces with and including all fitting, allas specified by Engr-in-charges. 123 M&L for cutting existing GI/CI pipe line of size 40/25 mm dia pipe making new connection for GI pipe including short pieces , inserting tees, bends ,sockets, unionetc with existing water line, complete all as specified and directed 124 S&F stop valve 25 mm dia cast copper alloy screwed on high pressure with crutch or butterfly handle screwed bolts ends, for iron pipe or for union and fixed complete all as specified and directed. 125 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed 126 Taking down distribution boards/wooden board ,switch fuse units,steel enclosures for MCB of any type and removing from site complete all as specified and directed. 127 Taking down existing unserviceable submain wiring of any size and making good the disturbed surface complete all as specified and directed. 128 M&L for modular point wiring for light point with 1.5 sqmm (nominal area) PVC insulatedFRLS and unsheathed multistranded copper conductor cable 1100 volts grade drawn through and including PVC rigid concealed conduit not less than 1.8 mm thick (ISI marked)with all accessories including suitable modular plate (Inner + Outer) and modular metalic boxes of suitable sizes including 1.5 sqmmPVCFRLS insulated unsheathed copper conductor multistranded cable for continuous earth conductor connectedto common earth dolly, complete all as specified & directed. Note:- Proper colour coding is to be followed as per IS Specification. 129 All as per item No. 128.00 here-in-before but for one light point controlled by two switch 6 Amp SP, two way, 240 Volts. 130 All as per item No. 128.00 here-in-before but for one 5 pin 6 Amp socket outlet point on same board controlled by one way switch SP, one way 6 Amp, 240 Volts 131 All as per item No. 128.00 here-in-before but for one 5 pin 6 Amp socket outlet point on independent board controlled by one way switch SP, one way 6 Amp, 240 Volts 132 All as per item No 128.00 here-in-before but using 2.5 Sqmm (nominal area) multistranded copper conductor cable including 2.5 Sqmm size FRLSH PVC insulated and sheathed copper conductor cable as earth conductor (green colour) connected to common earth dolly for one 6 pin socket outlet 16 Amps multi purpose on independent point complete all as specified and directed. 133 All as per item No 128.00 here-in-before but using 4.00 Sqmm (nominal area) multistranded copper conductor cable for geyser sheet metal plug socket outlet/metal plug topincluding 4.00 Sqmm size FRLSH PVC insulated and sheathed copper conductor cable as earth conductor (green colour) connected to common earth dolly for geyser on independent point complete all as specified and directed. 134 M&L in replacement ofSub main wiring intwo single run FRLS PVC insulated cable 6 Sqmm (Nominal dia) copper conductor (multistrand) and drawing in and including new PVC concealed non metallic conduit pipe ISI marked including one run 6 Sqmm multistranded copper conductor FRLS PVC green colour insulated unsheathed cable for earth continuity complete all as spd and directed. 135 M&L in replacment for Modularswitch 1 way 6A, 1 module complete all as specified and directed. 136 M&L in replacment for Modular switch, 2 way 6A, 1 module complete all as specified and directed. 137 M&L in replacment for Modular 1 way 16A, 1 module complete all as specified and directed. 138 M&L in replacment for Modular socket out let, 6 pin 5/6 and 15/16 amps multipurpose, 2 module 2 in 1 flush type, 240 volts with polycarbonate body complete all as specified and directed. 139 M&L in replacment for Modular socket 2 in 1, 6 amps 2/3 pin Combined 2 Module , 240 volts. with polycarbonate body complete all as specified and directed. 140 M&L in replacement of Modularbell push flush button,SP one module 5 amps 240 volts with polycarbonate body complete all as specified and directed. 141 S&F in replacement of MCB Protected Socket With sheet steel Enclosure single pole 20 Amp with 3 pin plug topfor AC connection from Socket point to stabilizer complete all as specified and directed. 142 S&F in replacement of Buzzer, Bell Ding Dong, AC 230 volt, Single Pole complete all as spd & directed 143 S & F in replacement of lamp holder batten type polycarbonate body with back plate for batten fitting, fixing with proper round block all as directed by Engr-in-Charge. 144 Supply and fixing in replacement of LED Lamp 9/10 watt B-22 holder base with polycarbonate body and aluminium heat sink warm white complete all as specified and directed by Engineer - in - Charge. 145 M&L in replacement ofceiling rosesurface bakelite 2 to 3 terminals with polycarbonate body complete all as specified and directed. 146 S & Fof decorative wall light white in colour made up of polycarbonnate body suitable for and including 9 watts retrofit LED lamp B 22 Base complete all as specified and directed. 147 S&F in replacment of LED lights fitting 1x 20W,minimum 3.5 feet 220V, AC decorative box type with driver, holder including LED tube light connecting up with flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. 148 S&F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. 149 S&F in replacement of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. 150 S&F of 5 star rated BLDC (Brush less direct current motor) ceiling fan 230 volts, single phase of 1200 mm Sweep with regulator doubleball bearing type with minimum air delivery 210 CFM with service value shall not less than 6.0 B.E.E including blade, down rod, canopy cover white colour etc, connecting 3 core flexible copper contuctor cable and dismantling of old unserviceable ceiling fans and depositing to MES store yard, complete all as specified and directed by Engr-in-Charge 151 Taking down the old unsv Geysers any size or type from the existing siteand depositing to MES store yard all as specified and directed by Engineer - in - Charge. 152 S&F exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers complete all as specified and directed. 153 M & L for cutting hole in brick/stone masonary wall and provision of PCC 1:3:6 for making proper suitable size of hole to matching with size of exhaust fan for proper ventilation including MS bolts 04 Nos forfixing exhaust fanall as spd and directed.Note : (i) Rates are deems to be included to making the cutting hole smoothly and colour wash as per exisiting colour.(ii) Rates are deems to be including charges of hiring T & P, i.e. ledder square foldingand insurance of labour deployed, being holes are made to be at mutlistorage bldgs of different height . 154 Supply and installing of the electric water storage heater of ABS body type of 25 ltr capacity with rated power 2 KW, 5 star rated, vertical type, thermally insulated mild steel tank with glass line coating inside the tank alongwith glass lined incoloy heating element with anti corrosive magnesium anode, NRV, thermostate, indicators and temprature adjustable knob including steel braided flexible connection for pipe of size 15 mm dia bore with G I hexagonal adopters/Nuts on the both sides for inlet ( cold water supply) & outlet ( hot water supply) and including provision of wall mounting arrangement and mounding wall with suitable size of anchor bolts with complete connection of water including testing after installation complete all as specified and directed by Engr-in-Charge . 155 Taking down electric enerty meter single phase any size or type form the existing site and refixing the same at same place after carrying out necessary repair work and making the surface good to match with existing surface all as specified and directed by Engr-in-Charge. 156 Supply and fixing LED security light fittings 35 watt, IP 65 having pressure die cast aluminium alloy housing, prismatic polycarbonate cover complete including making connection with 3 core copper flexible cable of suitable size including galvanised iron pipe bracket 0.90 mtr long of 25 mm dia and fixing with bldg for fixing of street light fitting all as directed. 157 S & F SPN 8 waysheet metal enclosures factory made DB double door 230 V AC, 50 Hz AC 200 Amp rated bus bar complete all as specified and directed 158 S&F240V, 10 KA B curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioningcomplete all as specified and directed. 159 S&F 240V, 10 KA B curve miniaturecircuit breaker (MCB) of single poles and current carrying capacity 40 AMP, in the MCB DB Complete with connection testing and commissioningcomplete all as specified and directed. 160 S&F amp rating 240V, 10KA C curve miniature circuit breaker (MCB) of SPN 40 Amp current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. 161 S&F MCCB TP 125 Amp 415V 16KA fixed type suitable for VTPN DB complete with connection testing and commissioning complete all as specified and directed. 162 S & F VTPN DBs Double Door4 way suitable for MCCB incomer, IP 43 protection 415 V AC, 50 Hz AC appropriate size of bus bar and neutral link complete all as specified and directed 163 M&L for earthing complete with galvanized steel earth plate electrode 60cmX60cm X6mm thick buried directly in ground (earth plate not less than 2.25 mtr deep below the normal ground level) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth lead wire of 4.0mm dia by means of nuts bolts, washers, check nuts of iron or steel includingPCC pits and RCC cover in PCC 1:2:4 (type B-1) and necessary earth work in any type of soil medium grade GI watering pipe 20 mm dia with funnel and wire mesh and 15mm bore GI pipe light grade protection pipe upto test point etc including excavation and charcoal, common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I. all specified 164 Note: (i) In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.(ii) The Schedule of Credit amount shall be deducted from the total of this schedule (BoQ) to arrive at Contract Sum.