}

Tender For Repair/Maintenance Of Fire Hydrant System At Mil Stn Kota, kota-Rajasthan

Tender Notice

52270227
Tender For Repair/Maintenance Of Fire Hydrant System At Mil Stn Kota
Tender
Indian
Rajasthan
Kota
26-11-2025

Tender Details

Tender For Repair/Maintenance Of Fire Hydrant System At Mil Stn Kota; 1 S&F in renewal of MS flanged pipe of 100mm nominal bore, heavy duty, for multistorey building duly painted with two coats of synthetic enamel paint (color as per IS norms of fire fighting color code) over a coat of Zinc chromate pirmer complete all as specified and directed. 2 S&F in renewal of Butterfly valve, 100 mm dia bore, heavy duty with CI body, liver operated IS-13095 marked including jointing materials i.e rubber gaskets, nuts, bolts etc complete all as specified and directed. 3 S & F in renewal of 3 phase contactor of suitable size and as per site requirment for pump motor of any capacities starters complete all as specified and directed. 4 S&F in renewal of existing single phase preventer complete all as specified and directed. 5 Supply only rubber gaskets for flanged joint superior quality for 100 mm dia flanges pipe complete all as specified and directed. 6 Dismantling carefully the AC electric motors of capacity upto 12.5 HP induction type, three phase, from the foundation, cutting down and removing the old burnt winding wire from the motor unit,rewinding the same with new super enameled copper winding wire as per existingsize/gauge of wire, providing necessary insulation by varnishing and drying the same upto specific temperature of heat, replacing insulation paper sleeves with connecting insulating material, tapping and providing necessary connection to the motors assembly reinstalling, commissioning and testing the pumping set upto good working performance complete all as specified and directed. 7 M & L for metal filling, welding, turning cutting, preparing the centrifugal pump/jockey pump shaft uptostandard size including hardening smoothing etc and bearing housings NDE andDE side, including checking & servicing of impeller and making pump fully functional for 440 volt 3 phase 50 Hz 35 M head 54 cubmetre per hr discharge complete on lath machineasper site requirement complete all as specified and as directed. 8 Supply only in renewal of following spare parts of existing make for centrifugal pump capacity upto 12.5 HP for srl item No 7.00 (here-in-before) : -Inter staging rings (Set of two Nos) 9 Inter casing rings (Set of two Nos) 10 Bushes Gun Metal 11 BearingNDE/DE 12 Motor terminal plate having Nuts and bolts studs. 13 Shaft sleeves mild steel. 14 Coupling set with nut bolt and washer. 15 S&F in renewal of Star-Delta Starter with sheet enclosure outdoor type 3mm thickof suitable size for 12.5 HP capacities motor in existing location incl making electric connections with PVC insulated 1100 volts grade single core multi stranded copper conductor complete all as specified & directed. 16 S&F in renewal of cast iron non return valve ball type, heavy duty both ends flanged drilled holesincluding two nos of flanged ends including 2 flanged joints and jointing material i.e. nuts, bolts, washers, rubber gaskets etc of size 100 mm dia NRV complete all as specified & directed. 17 M&L for Earthing with galvanized steel earth plate electrode of size 600 mm x 600mm x 6.0 mm, buried directly in ground (earth plate not less than 2.25 Mtr below normal ground level) connected to galvanized earth strip of 25x4 mm dia by means of bolts, buts, check nuts and washers of galvanized iron on steel including 50 mm bore light grade GI tubing for protection of earth strip, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm bore, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type 75 mm thick precast RCC (1:2:4) type B1 pit cover reinfored with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar including GI earth strip of 25x4 mm size for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spolis to a distance not exc 50 Mtr and necessary connection and testing complete all as shown in electrical plate No. 3 and including dismantling of old unserviceable earthing complete all as specified and directed. (Earth lead strip and GI protection pipe beyond 7.50 m shall be measured and paid separately). 18 M & L for repair of Non return valvevalve alongwith its gasket & connected accessories upto 100 mm dia complete all as specified and directed. 19 M & L in renewal of worn out MS sheet portion of hose window framelocated at shaft of building using 18 SWG MS sheetdouble door& fixing of glass in replacement of brokenwith 4 mm thick glasses including painting of MS sheet with fire red outside and brilliant white inside complete all as specified and directed. 20 S & F in renewal of Hose reel drum for upto length 36 m, ISI Marked complete all as specified and directed. 21 M & L for painting MS pipe 100 mm dia, hose reel drum & metallic accessorieswith two coats of synthetic enamel paint (color as per IS norms of fire fighting color code) over a coat of Zinc chromate pirmer complete al as specified and as directed. Note :- Cost of T&P required for painting fire structure shall be included in the rate quoted. 22 M & L for welding, cleaning and any other minor repairrequired for smooth functioning ofAir Cushioin Tank/Air vessel upto 400 mm dia & upto 1500 mm high with dished top, made of minimum 6 mm thick MS Pipe/Plate complete including replacement (if required) of stop valve, pressure gauge and all accessories as per existing arrangement required including mounting bracket complete all as specified and as directed. ` 23 Attending complaints to pump & motors by qualified mechanic to check and test DOL/star-delta starter connections including settings of relay and timer, NO & NC contacts, main power connections, fixing of cable joints,fixing gland packing of approprate size to the pump motors, rectifying pump leakages alongwith pipe line leakges then welding, filling the leakage/gap including replacing flange, rubber packing and nut bolts of existing size and cleaning of pump motors to confirm the satisfactory running with replacement of following items. The cost of minor spares such as lugs of all size, wires, nut, bolts, washer, Flanges, rubber packing, gland packing, cable joints etc are included in quoted rate bycontractor.Note:-Repair to defects after informing within 24 hours, in case of failure noticed more than 24 hrs recovery shall be effected @ Rs.500/- per hour beyond 24 hrs. 24 Supply and fixing in renewal of hose reel of 20 mm innerdia and 30 meter length complete all as specified and as directed. 25 Supply and fixing in renewal of branch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090 (one FHC each floor) complete all as specified and as directed. 26 Providing and fixing in renewal of High Pressure – 10L Water Mist And CAF Fire Extinguisher Constant operating pressure of 34 bar with negligible recoil, Light weighted gun of 750 grams, Suitable for Class A, Class B and Live Electrical Fire, Ý System suitable for 35 KV as per EN 3 standard & 36 KV as per IS:15683:2006, Backpack and Hand Held System, Light weight anti corrosive aluminum alloy vessel/ CFRP - Carbon.,Fiber Reinforced PolymerPressure gauge on the vessel as per EN 3 standard cmplete all as specified and as directed. 27 Providing and fixing in renewal of 6 kg capacity Multipurpose dry chemical powder (ABC) type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged complete all as specified and as directed. 28 Providing and fixing in renewal of CO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683.Extinguisher shall be painted with red enamel apint and fixed to wall with bracket complete all as specified and as directed. 29 Supply, installing, testing and commissioning in renewal of microprocessor based Single-loop, True Peer-to-Peer Networkable Addressable Fire Alarm Control Panel with 600 characters LCD display, 4000 event plus 1000 alarm log history events, QWERTY keypad for programming. The panel equipped with sufficient numbers of loops considering 10% spare capacity in each loop. Each loop shall have a capacity of minimum 399 analog addressable devices. 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition. Communication Fire Fighters System capable of supervising all the speaker circuits with adequate zone control and accessories, wires, circuits, fasteners, clamps etc., complete all as specified and as directed with following specifications :- • Features & Benefits: Optional 40 or 80 zone alarm LEDs, Easy 5 key-press set-up, Large blue LCD display, Supports USB upload/download, Battery backed real-time clock (2 & 4 loop), 2 independent sounder circuits 500mA, multi-protocol loop driver, PC configuration software (supplied with panel), Sensitivity adjustment e.g. between day and night Input/output logic, Indicators: Fire, Fault, Disablement, Test, Buzzer Muted, Delayed Mode, Sounders Silenced, Sounders Disabled and Power. Also dedicated fault LEDs for System Fault, Sounder Fault, Supply Fault and Earth Fault. (F)Loop Capacity: 500mA per loop(G) NUMBER OF DEVICES CONNECT:Total number of devices 399 (199 NOS. MCPs, Modules & AV product + 200 SENSORS)MAKE: HONEYWELL MORELY- IAS DX MODEL-DXC4 (Networkable multi-protocol, analogue addressable fire alarm control panel). 30 Supply, installing, testing and commissioning in renewal of Sounder cum Strobe (Hooter) rated at 75 dBA @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication. Wall Mount Sounder by KAC’s base sounder, high quality loop powered device designed to alert building occupants of an emergency. It utilizes the System Sensor B501AP base for improved installation flexibility and integrates seamlessly with SS intelligent detectors. Triggered by the fire panel its powerful sounder gives an audible warning. A choice of output levels and tones make the device suitable for a wide variety of applications., complete all as specified and as directed with following Features & Benefits:- -Reduced install errors and easy fault finding-Reduced full life costs-Excellent system performance-Reduced inventory countCertifications:• EN54-3• VdS• LPCB 31 Supply, installing, testing and commissioning in renewal of Addressable Manual Call Point (Pull down / Break Glass Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the health status of the device.UL and FM ApprovedInstallation efficiency, compliance with the latest standards are at the heart of the call point range LED Status The LED status is controlled by fire panel and shows blinking RED each time the device is polled, or continuous RED to indicate fire complete all as specified and as directed with following :- FEATURES & BENEFITS• Unique ‘Plug & Play’ installation concept • Analogue addressable communications • Fully compliant with EN54, Part 11 • Integral LEHM-MCP-GLASS SPECIFICATIONS MECHANICAL Dimensions Semi-flush mounting: 89 x 93 x 27.5 (WxHxD) Surface mounting : 89 x 93 x 59.5 (WxHxD) Weight IP Rating Operating Temperature Relative Humidity: 110g IP24D 0°C to 49°C 10% - 93% non condensing PART NUMBERS HM/MCP/GLASS Addressable break glass manual call point Operating Voltage 15V to 32Vdc max Current Consumption Quiescent: 385µA Alarm Current: 7.8 mA With TEST KEYS. 32 Supply, installation, testing & commissioning in renewal of HPSR 2C x 1.5sq.mm. MICA taped fire survival cable insulated overall shielded BASEC & LPCB certified cable conforming to BSL7846 & BS6837 CWZ, BSEN 50200. The cable shall withstand 950 degree centigrade for 3 hours conforming to BSL6387 standard with mounting accessories required for mounting & tagging with clamps, plastic pipes, fasteners and all accessories. (FOR Fire Alarm and Detection System) complete all as specified and as directed.MAKE: POLYCAB/KEI/RR. 33 Supply, installation, testing & commissioning in renewal of FIRE SIGNAGES for indication / information of fire exit, alarm panel, fire extinguishers fire axe, hose reel, hydrents, lifts etc of size 12×4inches complete all as specified and as directed. 34 Supplying and fixing in renewal of Stainles Steel Single headed oblique pattern hydrant landing valve (internal/external) with 75 / 100 mm dia flanged inlet & 63 mm dia instantaneous type female outlet coupling with cast iron wheel complete with ABS cap and chain and all accessories as per IS:5290-93 (Type-A) in cluding matching flange (14 mm thick),nuts, bolts, washers, gaskets,etc as required complete all as specified and as directed & as per approved by GE. (Make -Safex) 35 Supplying and fixing in renewal of flexible hose made with 100% polyester, black EPDM internal rubber lining with External coat of canvass (IS:636, type-A)63 mm dia, 15 mtr. Long RRL hose pipe with instanteneous type 63 mm dia SS-304male and female couplings(IS:903) duly bound and riveted to hose pipes with GI rivets and GI wire etc. as required. Appropriate Test Certificate/ report with liable warranty of product/accessories from OEM shall be submitted., complete all as specified and as directed & as per approved by GE. (MAKE-SAFEX) 36 Supplying & fixing in renewal of SS-304 Short Branch Pipe conforming to IS: 903:93 fitted with 20mm (nominal internal diameter)bore nozzle, for projecting water in form of solid jet. The Branch shall have 63mm Male Instantaneous Inlet, suitable for use with 63 mm size Fire fighting hoses. H.P. tested to 21 kgf/cm² for 2.5 minutes complete all as specified and as directed & as per approved by GE. (MAKE- SAFEX) 37 Supplying and fixing in renewal of Single Door Hose Box Outdoor application Fire Hose Cabinet made of 1.6 mm thick MS sheetDuly powder coated in red color externally and white internally with 6 mm thick glazeddoors with Expanded Metal 2 mm thick Jali including necessary locking arrangement suitable to accommodate 1 Nos 15 Mtr.Long RRL Hose and 1 NoS. branch pipe on Existing Wall / Angle Iron Frame as required. (Cost of MS structure for mounting Frame is to be Paid Extra) complete all as specified and as directed & as per approved by GE. (MAKE-SAFEX) 38 Supply and fixing in renewal of water pressure gauge 0-300 Psiincl necessary valves reducers and nipple pipe as per existing complete all as specified and directed. (Make: H-Guru) 39 Supply, installation, testing & commissioning in renewal of Pressure switch For auto start/OFF of fire hydrant system complete all as specified and directed. (Make: DANFOSS) 40 S & F in renewal of feeder pillar box of outdoor type fabricated out of 3.0 mm thick CRCA sheet double door (front & back opening),CPRIapprovedcomplete with powder coating with seven tank process mounted on M.Sangle Iron frame of size 40x40x6mm, duly grouted with PCC reqd complete all as specified and directed with the following:-(a) Aluminium bus bar 400 Amp (R Y B & N) with colouredheat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set.(b) MCCB FP 250 Amps, 415 V, 25 KA- 01 No for main in coming (c) MCCB FP 100 Amps25 KA- 02(d) MCCB FP 63 Amps25 KA- 02(e) MCB SPN 6-32 A 10 kA-01 Nos(f) LED indicator for RYB of size 22.5 mm- Set of 3(g) Multifunctional meter forfreq, power factor, amperes, voltage etc.- 01 setNote: All MCCBs must conforms Fixed thermal and fixed thermal magnetic setting and Ics= 100% of IcuNote: Leg height of angle iron frame for panel must not be less than 100 cm above the PCC base to avoid water logging. 41 S& F in renewal of feeder pillar box of outdoor type fabricated out of 3.0 mm thick CRCA sheet double door(front & back opening),CPRIapprovedcomplete with powder coating with seven tank process mounted on M.Sangle Iron frame of size 40x40x6mm, duly grouted with PCC reqd complete all as specified and directed with the following:-(a) Aluminium bus bar 400 Amp (R Y B & N) with colouredheat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set.(b) MCCB FP 160 Amps, 415 V, 25 KA- 01 No for main in coming(c) MCCB FP 100 Amps25 KA- 02(e) MCB SPN 25 A 10 kA-02 Nos(f) LED indicator for RYB of size 22.5 mm- Set of 3(g) Multifunctional meter forfreq, power factor, amperes, voltage etc.- 01 setNote: All MCCBs must conforms Fixed thermal and fixed thermal magnetic setting and Ics= 100% of IcuNote: Leg height of angle iron frame for panel must not be less than 100 cm above the PCC base to avoid water logging.

Key Value

Document Fees
INR 500 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail