}

Tender For Provn Of Signal Equipment Store In Training And Institutional Area At Certain Units Of Misa Camp Under Ge(S) Tezpur, Nagaon-Assam

Tender Notice

52269833
Tender For Provn Of Signal Equipment Store In Training And Institutional Area At Certain Units Of Misa Camp Under Ge(S) Tezpur
Tender
Indian
Assam
Nagaon
28-11-2025

Tender Details

Tender For Provn Of Signal Equipment Store In Training And Institutional Area At Certain Units Of Misa Camp Under Ge(S) Tezpur; 1 Surface excavationin soft/loose soil n.exc 30cm deep and averaging 15 cm deepand getting out soft / loose soil complete all as specified and as directed. 2 Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m depth; n exc 10 sq m on plan and n exc1.5 m in depth and getting out soft/loose soil complete all as specified and as directed. 3 M&L for cement concrete Type D2 1:4:8 (40mm graded aggregate) in foundations, filling and mass concrete. complete all as specified and as directed. 4 M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical complete all as specified and as directed 5 M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions. 6 M&L RCC- M25 design mix Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete omplete all as specified and as directed 7 M&L for RCC M-25 design mix for columns, pillars, piers, posts and struts complete all as specified and as directed 8 M&L for TMT Bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips 9 M&L for TMT Bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required,including cranking, bending spirally for hooping for columns, hooping ends and binding 10 Returning filling inl.spreading, levelling, watering and well ramming in layers n. exc. 25 cm in hard/dense soilcomplete, all as specified. 11 Removing excavated material (Soil) n exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting pointcomplete, all as specified. 12 M & L foruse and wasteformwork to sides and soffit of suspended slabs such as roof slab, floor slabs, etc. with rough finished square/rectangular surfaces of concrete complete all as specified and as directed. 13 Material & labour for formwork to sides and soffits of concrete of beam, lintels, cantilevers etc. with rough finished square/rectangular surfaces of concrete complete all as specified and as directed. 14 Material & labour for formwork to as in chajjas with rough finished square/rectangular surfaces of concrete complete all as specified and as directed. 15 M&L for RCC M-25 design mix for Slabs supported on walls,beams and columns in floors, roofs, landings, balconies,canopies, deck slabs and in shelves and the like 16 M&L for RCC M-25 design mix for Slabs Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified & directed. 17 M&L for RCC M-25 design mix for Chajjas and similar works complete all as specified and as directed. 18 M&L for cement concrete Type C2 1:3:6 (40mm graded aggregate) in floor, filling and mass concrete. complete all as specified and as directed. 19 M & L Hardcore of guage exc 63mm but n exc 150mm deposited spread and levelled in layers n. exc 7.5cm thick, with broken stone, watered and rolled/rammed to a true surface, complete all as specified and as directed. 20 M&L for Sand fillingunder floors or infoundations and subbase etc including watering and consolidation ,complete all as specified and as directed. 21 M & L for Polythene film, black, 150 micron laid in floor ,complete all as specified and as directed. 22 M&L for 75mm thick P.C.C 1:4:8 type D-2 using 40mm graded stone aggregatefinished even and smoothas in plinth protection / sub base/ etc complete all as specified and directed. 23 M&L for Forming contraction(Dummy) joints 65 mm deep x 10 mm wide filled with Grade A sealing compound complete all as specified and as directed. 24 S&F vitrified Ceramic tiles 10 mm thick area of each tile not exceeding 0.36 sqm, in floors etc. set OVER 15mm thick screed bed in CM 1:6 and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed 25 All as per item no 24 abovebut on skirting over 10mm thick backing coat in CM 1:4 complete all as specified and directed 26 M&L for 15 mm thick screed bed in cm 1:4 mixed with WPC as per manufactures instruction finished even and smooth over RCC roof slab without using extra cement (WPC shall be measured seperately) complete all as specified & directed 27 M & L for water proofing treatment on existing cleaned RCC roof with the following specification and manufacturings instruction complete all as specified and as directed:-(a) Preparing and clening of fully dry surfaces as per IS3067-1966(b) Applying bitumen primer conforming to IS:3384-1968 over the cleaned plaster surface @ 0.5 Ltr per sqm(c) Applying a layer of APP based polymeric membrance 3.0mm thick (minimum) weight 3.6 Kg per sqm (reinforced) with polyster Non woven fabric weighing not less than 160gms per sqm by torch application.The over laps shall be minimum 100mm on the transverse direction and 75 mm on longitudinal direction.(d) Applying one coat of aluminium paint @0.10 ltr per sqm over APP based polymeric membrane.Notes:- WPL work shall be executed by authorised applicator of approved product. 28 M & Lfor AAC (Autoclaved Aerated Concrte) block masonary, blocks(Block size 600x200x100mm or 600x200x150mm) having compressive strengthas per IS-2185 :1984 (Part-III) and set in Chemical mortar of BRIKOFIX or equivalent as per Mfr directions complete all as specified. 29 M & L for Rendering 10mm thick cement mortar 1:6 on fair faces of brick work or concrete surfaces even and smooth,complete all as specified and directed. 30 M&L for rendering 15 mm thick in CM 1:4 on other than fair faces of brick or concretesurfaces with water proofing compound @3% of weight of cement and finishing the surface even and smooth (without using extra cement) complete all as specified and directed.Note : Water Proofing compound shall be measured and paid separately 31 Supply only integral WPC 32 M & L for rendering 5mm thick cement mortar 1:4 on fair faces of brick work or concrete surfaces even and smooth on ceiling including prepation of new plastered surface complete all as specified & directed 33 Material & Labour for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. 34 M&L for three coats of white washing to ceiling including preparation of new surfaces.complete all as specified & directed 35 M&L for Distempering on new plaster surface with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturers specification. Two or more coats on new work applying a coat of 3mm thick alayer of wall care puttyon walls ofcomplete all as specified & directed 36 S & F powder coated Anodised aluminium frame for doors, three trackwindows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified 37 S & F powder coated Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified 38 S&F powder coating of any colour (Thickness or powder coating not less than 50 micron). Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified 39 Materials and Labour for mid steel framed work such as grills, gratings, gate, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed. 40 S&F 4mm thick ordinary quality sheet glass in squares exc 0.5 sqm in each pane fixed in aluminium frame complete. 41 S&F Galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperature 1.18 mm fitted with tinned tacles or galvanised wire staplescomplete all as specified and as directed. 42 M&L for preparation oldpaintedsurfacesof steeland ironsurfaces over 10 cm width or girthand applyingone coat ofsynthetic enamel paint complete all as specified and as directed 43 S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor overall length 150mm complete all as specified 44 S&F 300 mm Aluminium alloy anodisedsliding door bolt, plate type and fixing clip of sheet cast of extruded section and fixing bolt and sliding bolt of extruded section and fixed in position complete 45 S&F 200 mm aluminium anodisedbarrel tower bolt, of extruded sectionand fixed in position 46 M&L for extruded aluminium alloy handle fabricated type of 150 mm long 47 S&F 100 mm Butt hinges medium weight cold rolled mild steel and fixed. 48 Supplying and fix aluminum (extruded section) door closer hydraulically regulated designation No-1 universal type suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed. 49 Excavation in post holes (or similar holes ) each nexc 0.5 cum , getting out , returning , filling in and ramming earth or rubble mixed with earth around , in layers nexc 25 cm watering , and removing surplus soil to a distance nexc 50m and making good surface ofsoft/loose soil complete all as specified and directed 50 M&L brick work unsing sub class B brick curved or straight in plan exc 6 mtr mean radius in cm (1:6).complete all as specified and directed 51 M & L for PCCcopingtype B1 (1:2:4) using 20 mm graded stone aggregate 52 M & L for 20mm thick Granite (of any type) work (table rubbed and polished)in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed 53 S&F posts and struts in fencing including cutting tops to shape as directed , drilling holes , notching for wire , etc , flat iron fillets ( for securing wire mesh etc ) including all necessary drilling , bolting riveting etc and similar work confirmingto Fe-290 Gde E-165 Complete all as specified and directed. 54 M&L 25 x6mm thickflat iron fillets fixed to the fencing posts incl all necessary drilling bolting or riveting etc and similar work conforming ot Fe 410-0 or Fe 310-0.complete all as specified and directed 55 S&F 12 mm dia Mild screw bolts machine made) with hexagonal or square heads at one end and screwed the other, or screwed on both ends each screwed end to be fitted with washers and one hexagonal or square nut but length of bolt exc 10cm but n exc 15cm long.complete all as specified and directed 56 Suply onlychain link fencing 100x100x3.15mm, size to any type of standards, rails, straining bolts, etc incl provision of binding wire complete all as specified and directed 57 Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire 58 S&F 10mm diaMS roundbar fixed to chain link fening Top and bottom complete all as specified and directed 59 Preparation of newly steel surfaces nexc10cm and applying 2 coats of synthatic enamel paint over primer complete all as specified and directed 60 Preparation of newly steel surface exceeding 10 cm and applying two coats of synthetic enamel paint over primer complete all as specified and directed 61 M&L fornewly plaster surface and applying two coatsof cement base paint complete all as specified and directed 62 M & L for 75mm thickPlainCement concrete 1:3:6 type C 2 using 40mm gradded agg as inbedding of foothpath complete all as specified & directed 63 S & F Machine pressed precast concrete interlocking paver block gloosy fineshed of any shape and design complete all as specified and directed. size confirming to IS 15658-2006 of80 mm thickness, M-40 Grade. 64 M&L for Providing, cement concrete type B-1 (1:2:4) 20 mm graded aggregatein rounded or chamfered on edges Ditto, in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones,bed plates, kerbs not provided for in Itemwater troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed 65 M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium dutywith all accessories including modular GI boxes of suitable sizesincluding 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fanpoint controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan/call bell point/ Switch socket outlet 5 amps complete all as specified and as directed.Note: (i) Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (Rate deemed to be inclusive of cutting chases and making good disturbed surface). 66 All as per item No. 65 here-in-before but one 3 pin 5 ampsswitch socket commbination on the independent board with other switch complete all as specified and directed by Engineer-in-charge. 67 All as per item No. 65 here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge. 68 M & L for point wiring for socket out let on 16 Amps independent Boards controlled by one, one wayswitch using 2.5 sqmm nominal cross sectional areamultistrandedcopper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including metal flush box suitable for modular cover plate with frame of suitable size of 3M and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLS PVC insulated unsheathed earth wire and connecting to earth dolly andbrass screws, washers etc. complete all as specified and directed.Note: (i) Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (Rate deemed to be inclusive of cutting chases and making good disturbed surface). 69 S&FModular type switch6 Amps 230V AC single module one way complete all as specified and as directed. 70 S&F Modular socket out let 3 pin 10 Amps shuttered type 230V AC 2 module complete all as specified and as directed. 71 S&F Modular socket out let 3 pin 16 Amps shuttered type 230V AC 2 module complete all as specified and as directed. 72 S&FModular type switch16 Amps 230V AC single module one way complete all as specified and as directed. 73 Material and labour for ceiling rose polycarbonate isolated body 3 ways terminals complete all as specified and as directed.. 74 Supply and fix modular type electronic fan regulator 1/2 Module complete all as specified and as directed.. 75 Supply and fixing modular white cover plate with frame 3 modules complete all as specified and as directed. 76 Supply and fixing modular white cover plate with frame 4 modules complete all as specified and as directed. 77 Supply and fixing modular white cover plate with frame 6 modules complete all as specified and as directed. 78 Supply and fixing modular white cover plate with frame 8 modules complete all as specified and as directed. 79 Supply and fixing modular metal flush box 3 modules complete all as specified and as directed. 80 Supply and fixing modular metal flush box 4 modules complete all as specified and as directed. 81 Supply and fixing modular metal flush box 6 modules complete all as specified and as directed. 82 Supply and fixing modular metal flush box 8 modules complete all as specified and as directed. 83 Supply & fixing Modular type 25 Amps power unit combine with on/off switch complete all as specified and directed. 84 Supplying and fixing two single core ,6 sqmm nominal cross sectional areamultistrandedcopper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts gradedrawing in and including nd including suitable size PVC conduit (ISI marked) concealed including6 sqmm nominal cross sectional areamultistrandedcopper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earthwirecomplete all as specified. Note : Two run of 6 sqmm wire with one run of 6 sqmm and one run of conduit pipe shall be measured against one unit. 85 Supply and fixed18 W LED light fitting wall mounted batten 4ft ,minimumm lumen output 100 lumen/Wat, extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 18 watt,6500K including necessary connection complete all as specified and directed. 86 Supply and fixed security light fittings 30 watts, minimumm lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete including 25mm dia light grade GI bracket with nut bolt and clamp complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as directed. 87 Supply and fixed epoxy powder coated sheet metal enclosure for DBs, double door, Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed. 88 Supply and fixed epoxy powder coated sheet metal enclosure for DBs, double door, Triple pole and neutral 415 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed. 89 Supply and fixed MCB SP,6 to 32 Amps, C series 10kA, 240 Volts and to be housed in DBs including necessry connection complete all as specified and directed. 90 Supply and fixed MCB SPN 6-32 Amps,C series 10kA, 240 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed. 91 Supply and fixed MCB TPN 63 Amps,C series 10kA, 415 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed. 92 Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased inand including 40 mm dia GI lightgrade pipe from upper end of earth plate upto equipments,20 dia bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe andPCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as describedin electric plate of SSR Part I completeall as specified and directed and testing on completion. 93 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) all as directed. 94 S & F ventilating exhaust fan300 mm sweep 230 volt AC complete with louver and all accessories including cutting hole of suitable size, making good surface by doing plaster and applying two coat of distemper complete with fixing arrangement to wall connected with twin core twisted flexible copper conductor (23/.0076) of suitable size all as directed.

Key Value

Document Fees
INR 500 /-
Tender Value
INR 22 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail