| 1 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings and removal from sitecomplete all as specified and as directed. |
| 2 | Dismantling Floor, Paver Tiles, Hearth or Wall Tiling,etc. including Cement Mortar Bedding (but not backing) and removing debris, etc. to Outside MD/AF Land, complete all as specified and directed. |
| 3 | Taking down Cement Plaster including raking out Joints, hacking for Key, scrubbing down with Water and removing Debris, etc. to Outside MD/AF Land, complete all as specified and directed. |
| 4 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion alongwith PCC foundation and making good disturbed ground and removal from site complete all as specified and directed. |
| 5 | Demolition Cement Concrete (un-reinforced) of any description in Ground Floors, Pavings, etc. not exc. 150mm thickness (above or below Ground Level) and removing debris, etc. to Outside MD/AF Land, complete all as specified and directed. |
| 6 | Demolition Cement Concrete (un-reinforced) of any description and in any position not otherwise specifically provided for and removing debris, etc. to Outside MD/AF Land, complete all as specified and directed. |
| 7 | Dismantling wrought iron or mild steel work of any description in rafters, purlins and wind ties wtc and removal from site complete all as specified and directed.NOTE: If the planned MS structure, truss, etc is different from the existing structure, proper measurement of the existing structure to be demolished, shall be recorded in MB duly signed by the Engineer-in-Charge. |
| 8 | Excavating in post holes (or similar holes) each n exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed. |
| 9 | M&L cement concrete 1:2:4 of type B1 (using 20 mm graded stone aggregate) as in filling and mass concrete complete all as specified and as directed. |
| 10 | M&L for Rolled mild steel in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes without any attachment Gde Fe 410W complete all as specified and directed. |
| 11 | M&L for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut, exc 15 cm but n exc 22.5 cm long, diameter 16 to 20 mm complete all as specified and directed. |
| 12 | M&L for steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 or RHS/SHS Sections conforming to IS 4923:1997 grade YST 210 complete all as specified and directed.(NOTE: Quoted rates shall be deemed to include for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete. No extra measurement for the same will be considered except for anchor bolts and base plates at top & bottom of columns) |
| 13 | S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheetinghaving 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 smallstiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof completeall as specified and directed. |
| 14 | All as per Item No. 13 above but 0.50 mm thick colouredplain galvalume sheet as in ridge/valley gutter of roof. |
| 15 | Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and directed. |
| 16 | Removing excavated materialto a distance exc 250m but not exc 500m and depositing where directed at a level n exc 1.5m above the starting point. complete all as specified and directed. |
| 17 | M&L for Hardcore of broken stone or boulder of gauge not exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 18 | M&L for Cement concrete, 75mm thick, type C-2, 1:3:6 (40mm graded aggregate) in sub floors, sub bases, pavings etc., complete all as specified and as directed. |
| 19 | M&L for providing rubber moulded cement concrete coloured chequered tiles 300x300x22-25mm thick, set, jointed and pointed in neat cement slurry in floors, with grey cement and pigment, laid over and including 20mm thick screed bed in cement mortar 1:4 complete all as specified and directed.NOTE : Quoted rate shall deem to include the cost of cement screed bed. |
| 20 | M&L for Cement Concrete 1:2:4 type B1 (20mm graded stone aggregate) as in Coping, Bed Plates, Holdfast, Bed Block, Kerb Stonesincluding necessary Formwork and weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed. |
| 21 | M&L for Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.(NOTE: Quoted rate shall deemed to include for the cost of all GI anchor bolts & nuts, screws, rawl plugs, etc as required for fixing the grills/MS structure to walls or openings. No claim shall be entertained during currency of work. |
| 22 | M&L for Mild steel framed works such as grills, gratings etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tanks and similar works conforming to Fe-290 Gde E-165 complete all as specified and directed.(NOTE: Quoted rate shall deemed to include for the cost of all GI anchor bolts & nuts, screws, rawl plugs, etc as required for fixing the grills/MS structure to walls or openings. No claim shall be entertained during currency of work. |
| 23 | S&F Wire netting of galvanised steel wire 1.40 mm dia fixed with tinned tacks of wire staples, size of mesh 12 mm complete all as specified and directed. |
| 24 | M&L for complete removal of existing treatment on old painted surfaces of walls by scrapping andremoving layers of all wall finishes including cleaning, watering to make the surface clean and free from dust, etc including necessary scaffolding, safety and protective measures complete all as specified and directed. |
| 25 | Taking down old Steel / Wooden Chowkat or Frame not exc. 1.50 Sqm Each with shutter (without taking off shutter from the frame) and removal from site incl cutting holes in brickwork for removal of holdfasts complete all as specified and directed. |
| 26 | M&L for Brick Work with Fly-AshBricks (Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and directed. |
| 27 | M&L for Rendering (Internal) 15mm thick in cement mortar 1:6 on Brick Walls or on Concrete Surfaces, Plastered Surfaces finished Even and Smooth without using Extra Cement complete all as specified and directed. |
| 28 | M&L for preparing New/Undecorated Plastered Surfaces of Walls, applying a coat of suitable cement primer followed by a Coat of 1.50 mm thick Wall Putty (in two layers) including rubbing down with Sand Paper to obtain a smooth finish surface and finishing with Two Coats of Acrylic Distemper (as approved) as per desired shade/tint complete all as specified and as directed. |
| 29 | M&L preparing new or previously untreated Steel and Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a coat of Red OxidePrimer, complete all as specified and directed. |
| 30 | M&L for paintingtwo coats of synthetic enamelpaint over a coat of red oxide primer on new steel surfaces not exc. 10 cm width or girth including preparation of surfaces complete all as specified and as directed. |
| 31 | M&L for Cement concrete, 75 mm thick, type D- 2, 1:4:8 (40mm graded aggregate) in sub floors, sub bases, pavings etc., complete all as specified and as directed. |
| 32 | M&L for Cement concrete, 25 mm thick, type B-0, 1:2:4 (12.5mm graded aggregate) in sub floors, sub bases, pavings etc., complete all as specified and as directed. |
| 33 | M&L for providing Non-skid/matt finish Ceramic tiles, coloured, joint free,7-8 mm thick (Square / rectangular), area of each tile exceedig 0.11 Sqm but not exceeding 0.18 Sqmin Flooring, set and jointed in Neat Cement Slurry and pointed in White or Colour Cement to match the tiles, laid over and including Screed Bed 15mm thick in Cement Mortar 1:4, complete all as specified and as directed.NOTE : Cost of Cement Screed Bed shall deem to be included in the Quoted Unit Rate. |
| 34 | M&L for providingMachine cut Pre-Polished Kota Stone Tiles, 18-20mm thick in Flooring, laid over including 20mm thick screed base of cement mortar 1:6 and joined with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified and directed.NOTE : Cost of Cement Screed Bed shall be deemed to be included in the quoted rate. |
| 35 | M&L for Coloured Glazed Ceramic Tiles in vertical surface 450mm X 350mm X 6-7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the Tiles, laid over and including 10mm thick rendering as Screed or backing coat of wall tilein Cement Mortar 1:4, complete all as specified and directed.NOTE : Cost of Cement Screed Bed shall deem to be included in the Quoted Unit Rate. |
| 36 | Excavating in trenches, in soft/loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and as directed. |
| 37 | -ditto- but for depth exceeding 1.5 m deep & upto 3.00 m deep |
| 38 | M&L for Brick Work with Fly-AshBricks (Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:4, complete all as specified and directed. |
| 39 | M&L for Rendering (Internal) 15mm thick in cement mortar 1:4 on other than fair faces of Brick Work, Plastered Surfaces finished Even and Smooth without using Extra Cement complete all as specified and directed. |
| 40 | M&L for Cement concrete, 75 mm thick, type B-2, 1:2:4 (40mm graded aggregate) in sub floors, sub bases, pavings etc., surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 41 | M&L Pre-cast Reinforced Cement Concrete 1:2:4 (20mm graded stone aggregate) in Slabs, Manhole Cover Slabs, etc., set in Cement Mortar 1:4, with necessary formwork complete all as specified and as directed.NOTE : Reinforcement will be Measured and Paid separately under relevant Item. |
| 42 | M&L RCC 1:1½:3, type A1 (using 20mm graded crushed stone aggregates) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like. incl properly curing complete all as specified and as directed.(NOTE: Reinforcement & formwork shall be measured and paid separately) |
| 43 | M&L forformwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping for rough finished surfaces complete all as specified and directed |
| 44 | M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm widefor rough finished surfaces complete all as specified and directed |
| 45 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping forcolumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 46 | M&L for Mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary gusset plates, riveting etc. n. exc 10 kg each brackets, conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 47 | S&F PVC (SWR) 110mm bore (dia) Soil, Waste and Ventilating Pipe, single socketed, in any length with PVC Joints, with or without Ears, laid on floors, trench etc complete all as specified and directed. |
| 48 | Returning, filling in approved Soft/Loose Soil including spreading leveling, watering and well ramming in layers not exc. 25 Cm thick, complete all as specified and as directed. |
| 49 | Removing Excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point including spreading over ground, complete all as specified and as directed. |
| 50 | M&L Cutting into existing Manholes for Connecting New Drain Pipes of 150mm (Internal dia), Making Good to Pipe and rendering, cutting out existing Benching for and forming Branch Channel (½ Round or ¾ Section) in Cement Concrete 1:2:4 (20mm graded stone aggregate), Smooth Finished and Reforming Benching as required, complete all as specified and as directed. |
| 51 | Supply and laying Reinforced Concrete Pipes 150mm (internal dia), Class NP-3, laid in Trenches on Concrete Bed, to required Slope, jointed with jute & cement mortar 1:1, complete with collars all specified and as directed. |
| 52 | M&L Cement Concrete 1:3:6 (40mm graded stone aggregate) as in Concrete Bed to Drain Pipes of 150mm bore (dia), including packing under, and haunching against the sides of pipes after they are laid and testedcomplete all as specified and as directed. |
| 53 | M&L for construction of new Soakage well, 3.60m dia and 3.0m deep with permanent specifications including necessary earthwork complete all as shown on drawings and as specified and directed. |
| 54 | M&L for Mild steel works for framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and directed.(NOTE: Quoted rate shall deemed to include for the cost of all GI anchor bolts & nuts, screws, rawl plugs, etc as required for fixing the grills/MS structure to walls or openings. No claim shall be entertained during currency of work. |
| 55 | M&L for Rolled mild steel framed work, Fe-410W(Gde-E-250) quality-B as in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering), running rails and guides) and hanging; also fastening and fixing completeall as specified and directed.(NOTE: Quoted rate shall deemed to include for the cost of all GI anchor bolts & nuts, screws, rawl plugs, etc as required for fixing the grills/MS structure to walls or openings. No claim shall be entertained during currency of work. |
| 56 | Supply and fixing mild steel Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed.(NOTE: Quoted rate shall deemed to include for the cost of all GI anchor bolts & nuts, screws, rawl plugs, MS clamps, etc as required for fixing the collapsible gate to walls or openings. No claim shall be entertained during currency of work. |