| 1 | M&L for preparation of old decorated surfaces of wall and applying one coat of cement base paint complete all as specified and as directed. |
| 2 | M&L for preparation of old decorated surfaces of wall after complete removal of fungus etc and applying two coat of cement base paint complete all as specified and as directed. |
| 3 | M&L for preparation of old decorated surfaces of wall after removal of fungus etc and applying one coat of exterior grade emulsion paint including making good the surface by filling with wall care putty complete all as specified and as directed. |
| 4 | M&L for preparation of old decorated surfaces of wall and applying two coats exterior grade emulsion paint over a coat of primer complete all as specified and as directed. |
| 5 | M&L for complete removal of existing treatment and applying two coats exterior grade emulsion paint over a coat of primer over a coat of 1 mm thick exterior wall care putty including preparation of surface complete all as specified and as directed. |
| 6 | M&L for preparation of old painted wooden surfaces over 10cm in width or girth and applying one coat of synthetic enamel paint of any description/any height complete all as specified and as directed. |
| 7 | M&L for preparation of old painted wooden surfaces over 10cm in width or girth and applying two coats of synthetic enamel paint of any description/any height complete all as specified and as directed. |
| 8 | M&L for preparation of old painted steel surfaces over 10cm in width or girth and applying one coats of synthetic enamel paint of any description/any height, complete all as specified and as directed. |
| 9 | M&L for preparation of oldpainted steel surfaces over 10cm in width or girth and applying two coats of synthetic enamel paint. of any description/any height, complete all as specified and as directed. |
| 10 | Demolition of brick work built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 11 | M&L for brick work with sub class \"B\" bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 12 | Taking down cement plaster including raking out joints hacking for key, scrubbing down with water, complete all as specified and as directed |
| 13 | M&L for rendering 10mm thick plaster in CM (1:4) on brick or concrete surfaces of wall finished even & fair complete all as specified and as directed. |
| 14 | M&L for rendering 10mm thick plaster in CM (1:6) on brick or concrete surfaces of wall finished even & fair complete all as specified and as directed. |
| 15 | M&L for rendering 10mm thick plaster in CM (1:3) on brick or concrete surfaces of ceiling finished even & fair complete all as specified and as directed. |
| 16 | M&L for preparation of newly plastered surfaces of wall and applying two coat of cement base paint over a coat of primer complete all as specified and as directed. |
| 17 | M&L for preparation of newly plastered surfaces of Ceiling and applying two coat of cement base paint over a coat of primer complete all as specified and as directed. |
| 18 | M&L for applying two coats exterior grade emulsion paint on newly plastered surface of wall over a coat of primer over a coat of 1 mm thick exterior wall care putty including preparation of surface complete all as specified and as directed. |
| 19 | M&L for writing letters or figures (block, Roman, Italic or Indian) 10 Nos per CM height not exc 30cm high with one coat of synthetic enamel paint complete all as specified and directed. |
| 20 | M&L for Re-writing stops, commas, short-line, dashes, hyphens, brackets etc complete all as specified and directed. |
| 21 | Dismantling asbestos cement (corrugated, semi-corrugated etc) sheets in roof coverings complete all as specified and directed. |
| 22 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of old sheet complete all as specified and as directed. |
| 23 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of colour having tensile strength of 550 Mpa as in plain sheet as in ridges, gutters, facia bd etc, fixed with self tapping screws or \"J\" /\"L\" hooks including dismantling old sheet complete all as specified and as directed. |
| 24 | Dismantling timber scantling in fillets, rails, posts, rafters, purlins, etc. under 40 sqcm in section as in framed work complete all as specified and directed. |
| 25 | S&F Roof trusses (framed), trussed, Purlins, Crane Gantries, Rails and Fastenings and Heavy Bracket framing (Beam, Tee, Angle, Channel or Flat Sections) including distance pieces, cleats etc. incl necessary welding/ fabrications using Fe 290 (Gde-E-165) complete all as specified and directed. |
| 26 | M&L for preparation of new or previously untreated steel surfaces over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 27 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for cement concrete, complete all as specified and as directed. |
| 28 | M&L for PCC 1:2:4 type B0 (Using 12.5mm graded agg) in roof kerbs or mud stops, rounded or chamfered on edges chajjas complete all as specified and directed. |
| 29 | S&F in repair 15 mm bore GI water tubemedium grade with all fittings and fixed to wall, floor and ceiling etc including taking down, complete all as specified and as directed. |
| 30 | S&F in repair 20 mm bore GI water tubemedium grade with all fittings and fixed to wall, floor and ceiling etc including taking down, complete all as specified and as directed. |
| 31 | S&F in repair 25 mm bore GI water tubemedium grade with all fittings and fixed to wall, floor and ceiling etc including taking down, complete all as specified and as directed. |
| 32 | Disconnecting existing tanks, setting aside (for lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position (Cleaning repairing etc measured separately) capacity 500 ltrs complete all as specified and directed. |
| 33 | M&L for preparation of old surfaces of bands, fins, facias, floors, paths etc and applying one coat of terracota of selected colour / shade of 1st qualityor equivalent paint as approved by engineer-in-charge of matching shed as directed complete all as specified and directed. |