| 1 | Supply, Installation, Testing & Commissioningin repair of Microprocessor based Networkable Analogue Addressable Fire Alarm Control Panel. The Panel shall be completed with EN54-2,EN54-4 and approved by LPCB. The Fire Alarm Control Panel shall have inbuilt 6 Loops & Expandable to 16 loops. The Panel must also have the capability to take Addressable intelligent Wired and Wireless Devices on same loop. Each loop shall have a capacity of 127 analogue Addressable devices and 127 Base sounders/Base Sounder Beacons. The panel shall have an event log of minimum 10,000 events @ 1 second resolution, Filterable and Printable. The Panel shall have Three access levels. Panel shall support upto 5000 Cause & Effects entries, with upto 20,000 inputs controlling & 20,000 Controlling outputs across the network. The Panel shall have capability for Peer to Peer networking through RS485 network card. The Panel must have 4 inbuilt programmable sounder circuits, each circuit rated at 2.5A.The Panel must have inbuilt 3 programmable inputs and 5 inbuilt Pgrammable relay outputs. The Panel shall have up to sub-addressable 512 programmable Inputs/Outputs via optional RS485 COMMS serially connected expansion cards. The Panel shall have 240 V AC power supply along with automatic Battery Charger. The Panel shall be fully expandable via common plug in loop driver boards. The user shall have a choice of using the panel with 5.25 Amp or 10.25 Amp power supply unit which is inbuilt in the FACP and should be approved to EN54-4. The Panel shall have configurable via USB port to PC or memory stick. The Panel shall have dedicated RS232 serial port for optional printerapproved by LPCB.Make-FAS Panel NFS 320 Notifier /Honeywell/Siemens/HFP/BOSCH |
| 2 | Supply, Installation, Testing & Commissioningin repair ofmulti spectrum (UV/IR) fire and flame detector with pneumatic cleaning complete with the following accessories and specifications :-(a) Mounting accessories included,(b) Operating Voltage- 24 Vdc nominal (18-32 Vdc) regulated ,(c) Communication RS-485 , Modbus protocol,(d) Enclosure type 4X, IP66 and NEMA 4 ,(e) Enclosure Materials - Copper free powder coated Aluminium ,(f) CERTIFICATIONS : ATEX/IECEx : II 2 Ex db IIC T4 (Ta :-40 to +100 degree celsius) , II 2 D Ex tb IIIC T135 degree celsius /ISI/ UL ,(g) SENSITIVITY : Switch Selectable - Very high (60m) , high (45m) , medium (30m) and low (15m), (h) RESPONSE TIME : 3-5 seconds to 0.1 sqm (1 sqft) n-heptane fire at 30 m (100ft) , 3-10 seconds to 0.1 sqm (1 sqft) n-heptane fire at 60 m (200m), (k) SPECTRAL SENSITIVITY : Ultraviolet 185-260 nanometres ,(l) With Canopy : Near Band IR: 0.7 - 1.1 microns and Wide Band IR: 1.1-3.5 microns Make: BOSCH / Notifier / Gemwell / Honeywell/SIEMENS |
| 3 | Supply and fix in repair Isolators module for isolating short/dewired/loose circuits with automatic resetting arrangement,with provision of isolators base . The device shall be have an LED which shall blinking normal state & get steady on activation to monitor the health status of the device and module shall be supplied with mounting plate from OEM for ease of Installation and maintenance complete all as specified and as directed . |
| 4 | Supply,Installation,testing and comissioning in repair of Beam Master detector with Transreceiver & receiverincluding control module, power supply module, monitor module, relay module suitable for 6 loop fire alarm system complete in all respect and all as specified and directed. |
| 5 | Supply,Installation,testing and comissioningin repair ofPower supply unitBox panel of 12 VOLT / 7 AH BATTERYsuitable for 6 loop fire alarm complete in all respect and all as specified and directed. |
| 6 | Supply,Installation,testing and comissioningin repair of PC NETWORK CARDsuitable for 6 loop fire alarm complete in all respect and all as specified and directed. |
| 7 | Supply,Installation,testing and comissioningin repair of Onyx workstation software suitable for 6 loop fire alarm complete all as specified and directed. |
| 8 | Supply,Installation,testing and comissioningin repair of Network Communication Modulesuitable for 6 loop fire alarm complete in all respect and all as specified and directed. |
| 9 | Supply,Installation,testing and comissioningin repair ofControl Modulesuitable for 6 loop fire alarm complete all as specified and directed.Make: BOSCH / Notifier / Gemwell / Honeywell/SIEMENSMake: BOSCH / Notifier / Gemwell / Honeywell/SIEMENS |
| 10 | Supply,Installation,testing and comissioningin repair of Relay Modulesuitable for 6 loop fire alarm complete in all respect and all as specified and directed. Make: BOSCH / Notifier / Gemwell / Honeywell/SIEMENS |
| 11 | Supply,Installation,testing and comissioning in repair ofMultidetector with basesuitable for 6 loop fire alarm complete in all respect and all as specified and directed.Make: BOSCH / Notifier / Gemwell / Honeywell/SIEMENS |
| 12 | Supply,Installation,testing and comissioningin repair of8 zone Intrusion Alarm systemsuitable for 6 loop fire alarm complete in all respect and all as specified and directed. Make: BOSCH / Notifier / Gemwell / Honeywell/SIEMENS |
| 13 | Supply,Installation,testing and comissioning in repair ofmotion sensor PIRsuitable for 6 loop fire alarm complete in all respect and all as specified and directed. Make: BOSCH / Notifier / Gemwell / Honeywell/SIEMENS |
| 14 | Supply,Installation,testing and comissioning in repair of Auto dialer with ethernet connectivitysuitable for 6 loop fire alarm complete in all respect and all as specified and directed. |
| 15 | Supply,Installation,testing and comissioningin repair of120 Lt PESO approved Cylinder assemblysuitable for 6 loop fire alarm complete in all respect and all as specified and directed. |
| 16 | Supply,Installation,testing and comissioning of Agent - HFC-227ea Gas (Hepta fluro propane)suitable for 6 loop fire alarmcomplete in all respect and all as specified and directed. |
| 17 | Supply,Installation,testing and comissioning in repair of Electric Cum Manual Actuator complete in all respect and all as specified and directed. Make: BOSCH / Notifier / Gemwell / Honeywell/SIEMENS |
| 18 | Supply,Installation,testingin repair50mm Discharge Hose Flexiblesuitable for 6 loop fire alarm complete in all respect and all as specified and directed. |
| 19 | Supply,Installation,testingin repairof Warning Signsuitable for 6 loop fire alarm complete in all respect and all as specified and directed. |
| 20 | Supply,Installation,testingof Pressure operated control head suitable for 6 loop fire alarm complete in all respect and all as specified and directed. |
| 21 | Supply,Installation,testingin repair of 50mm Discharge Hose Flexiblesuitable for 6 loop fire alarm complete in all respect and all as specified and directed. |
| 22 | Supply,Installation,testingin repairof Flexible Actuation Hosesuitable for 6 loop fire alarm complete in all respect and all as specified and directed. |
| 23 | Supply,Installation,testing in repairof Master Cylinder Adaptor kitsuitable for 6 loop fire alarm complete in all respect and all as specified and directed. |
| 24 | Supply,Installation,testing in repairof Elbow connectorssuitable for 6 loop fire alarm complete in all respect and all as specified and directed. |
| 25 | Supply,Installation,testingin repair of Manifold check valve, 50mmsuitable for 6 loop fire alarm complete in all respect and all as specified and directed. |
| 26 | Supply,Installation,testingin repairof Discharge Nozzle suitable for 6 loop fire alarmcomplete in all respect and all as specified and directed. |
| 27 | Supply,Installation,testingin repair of Cylinder Strap for 120 Lt IS Cylinder suitable for 6 loop fire alarm complete in all respect and all as specified and directed. |
| 28 | Supply,Installation,testingin repair of Manifold Discharge Pressure Switchsuitable for 6 loop fire alarm complete in all respect and all as specified and directed. |
| 29 | Supply,Installation,testing in repair of Cylinder Low Pressure Supervisory Switch (Optional)suitable for 6 loop fire alarm complete in all respect and all as specified and directed. |
| 30 | Supply,Installation,testingin repair of 2 Zone Conventional Gas Realease Panel (Gas suppression system )suitable for 6 loop fire alarm complete in all respect and all as specified and directed. |
| 31 | Supply,Installation,testing and comissioning in repair of ( Conventional smoke detectors)adressable smoke Detectors Complying with and type certified to EN-45 type multisensor detector with heat and smoke combination Photoelectric / Optical with base with self built intelligence as per IS: 11360all as specified. Make: BOSCH / Notifier / Gemwell / Honeywell/SIEMENS |
| 32 | Supply,Installation,testing and comissioningin repair ofManual Abbort switchadressable break glassExplosive proofManual Abbort switch pointincluding sunken boxes, with built in monitor module will all acessories and signal indicator complete as per tech specification and shall be UL listed complete.Make: BOSCH / Notifier / Gemwell / Honeywell/SIEMENS |
| 33 | Supply,Installation,testing and comissioningin repair of Manual Release Switchadressable break glassExplosive proofmanual call pointincluding sunken boxes, with built in monitor module will all acessories and signal indicator complete as per tech specification and shall be UL listed complete. Make: BOSCH / Notifier / Gemwell / Honeywell/SIEMENS |
| 34 | Supply and Installationin repair of Conventional Hooter Fire Alarm Sounders / Sirens Electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of +5 DB 1500 mtrs range with starter and all connected items all as specifiedMake: BOSCH / Notifier / Gemwell / Honeywell/SIEMENS |
| 35 | Supply, laying & testingin repair PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,2 core, 1100 Volts grade with Stove enamelled, blank, rigid steel conduit, welded 25 mm dia complete in all respect and all as specified and directed |
| 36 | S & F in repair of LED light fitting 1/2x 16 watt flame proof , CMRI certified recommended for gas / vapour/ group of IIA& IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixture , driver, holder, connector etc . complete with all accessories prewired and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.Make : Shyam, Sudheer |
| 37 | Note for Srl No 1 to 36The quoted rate shall include all works required for connecting, testing, and commissioning all parts of fire alram system including submission of layout plan,Conduct of Training on Operation and Minor maintenance of fire alram systemat NGCCM and MPU section and deploying One Service Engineer, One Electrician and two helper complete all as specified and as directed .Note :-(i) all items to be executed through OEM or OEM certified agencies as approved by GE and as per OEM recommendation and OEM authorisation certificate to be submited to the dept before commencement of work .(ii) Complete layout plan for installation of fire alarm system is to be submited to the dept (iii) Any other parts/ items not specified above but have been required essential for this panel system shall be considered in quoted rate |
| 38 | M&L for Welding, Testing and Commissioning of gas suppression system and other works complete in all respect and all as specified and directed |
| 39 | Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth and getting out soft /loose soil complete all as specified and as directed |
| 40 | Returning, filling in, including spreading, levelling, watering and well remmining in layers not exc 25 cm complete all as specified and as directed |
| 41 | Removing excavated material n.exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point all as directed. |
| 42 | M & L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as inhold fast filling etc complete all as specified and directed. |
| 43 | M&L 100mm thick PCC 1:2:4 type B-1, using 20mm graded stone aggregate as in flooring/hard standing/paved area etc finished even and smooth without using extra cement including spike rolling to surface or making impression of expanded metal whilst the concrete is green complete and all as specified and directed. |
| 44 | M & L for 100 mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as insub base etc complete all as specified and directed. |
| 45 | M & L Machine pressed precast concrete interlocking paver block vibro compacted rubber moulded with greay cement and pigment any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade over sand cushion of 50 mm thick completeall as specified and directed |
| 46 | M&L plain cement concrete (1:2:4) type B-0 using 12.5 mm graded stone aggregate as in coping complete all as specified and directed. |
| 47 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 etc complete all as specified and directed. |
| 48 | M&L for Preparation of new steel surface applying two coats of synthetic enamelled paint over a one coat of redoxide primercomplete all as specified and directed. |