| Sl. No. | Item Description |
| 1 | Excavation in trenches n exc 1.50m wide and n exc 1.50m in depth for foundation, fixing of pole, laying of cable etc getting out in any type of soil, complete all as specified and directed. |
| 2 | Returning filling, in including spreading , levelling, watering and well ramming in layers not exc 25 cm each complete all as specified and directed. |
| 3 | Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 4 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n.exc 1.50 sqm each complete all as specified and directed. |
| 5 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm and n.exc 4 Sqm each complete all as specified and directed. |
| 6 | Taking down cement plaster on brick walls or stone walls of any description etc including raking out joints, hacking for key, scrubbing down with water etc, rubbish off the premises complete all as specified and directed. |
| 7 | Taking up or down steel water tubing and connections including cleaning for refixingof pipe 15mm bore or removal to store complete all as specified and directed. |
| 8 | Taking up or down steel water tubing and connections including cleaning for refixingof pipe 20mm bore or removal to store complete all as specified and directed. |
| 9 | Dismantling of brick work built in cement mortar including all quoins, arches, pillars etcand removal of debris/rubbish off the premises etc complete all as specified and directed. |
| 10 | Demolition of cement concrete (unreinforced) of any description and in any position and removal of rubbish beyond MOD land complete all as specified and directed. |
| 11 | Hacking out old broken glass ( any thickness , size, quality, or description) from metal frame glazed with putty or fixed with beads/ clips, rubbish off the premises complete all as specified and directed. |
| 12 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etccomplete all as specified and directed. |
| 13 | Repair to old steel window not exc 1 sqm including replacement of unserviceable/ damagedhinges, all handles, necessarywelding to shutters and chowkhat for making window in serviceable condition including two coats of synthetic enamel paint, complete all as specified and directed. |
| 14 | S&F Box type Steel windows and ventilators comprised of tubular frameand shutters made out of 1.25mm thick MS steel tube factory made with double side shutters wire gauged shutter & glass glazed shutter with side hung shutters with steel handle and steel peg staydovetailedor welded including 2 Nos tower bolts 150mm long for each leaf and 8mm square bar grills at spacing as shown on drg welded to FI frame work, including other fittings, hinges, handles, tarred hold fasts, PCC blocks (1:2:4 type 12.50mm graded crushed stone aggregate) including wire mesh and plain/ frosted glass &two coats of synthetic enamel paint over a shop coat of red oxide primer etc. all as shown on drg No CEPZ /TD-354/09 sheet 1/3 to 3/3 complete all as specified and directed. |
| 15 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 65x100 mm (double rebate) comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/ moisture proof and fire retardant, fixed in position with and including MS hold fast/lugs/SS dash fasteners of required dia and length completeall as specified and directed.Note: (i) For WPC solid door/window frames minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. (ii) Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified and directed. |
| 16 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 50x75 mm (single rebate) comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/ moisture proof and fire retardant, fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length completeall as specified and directed.Note: (i) M.S. hold fast/ lugs or SS dash fasteners shall be paid separately.(ii) For WPC solid door/window frames minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. (iii) Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified and directed. |
| 17 | Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately). |
| 18 | M&L 20 mm thick cement plaster in cement mortar 1:4 on brick or concrete surface of sunken floor finished even and smooth using WPC liquid of make Dr. Fixit or STP as per manufacturer instruction @ 0.200 ltr in 50 Kg of cement complete all as specified & directed (WPC shall be measured and paid separately) |
| 19 | M&L 10 mm thick cement plaster in cement mortar 1:4 on brick or concrete surface of sunken floor finished even and smooth using WPC liquid of make Dr. Fixit or STP as per manufacturer instruction @ 0.200 ltr in 50 Kg of cement complete all as specified & directed (WPC shall be measured and paid separately) |
| 20 | M&L forcement concrete 1:2:4 Type B1 (using 20 mm graded crushedstone aggregate) as seismic, plinth and similar bands, coping, kerbs, cills, steps, parapets, apex stones, bed plates, kerbs, railings upto 60 cm in height,water troughs and the like rounded or chamfered on edges including necessary form work complete all as specified and directed |
| 21 | M&L PCC 1:2:4 type BI (using 20mm graded stone aggregate) as in coping, benching for manholes including necessary form work complete all as specified and directed. |
| 22 | M&L for preparation of surfaces and apply first coat fiber reinforced elastomatic liquid water proofing membrane formulated with PU hybrid ploymersand reinfoecing acrylic fibers with sun reflective index(SRI) of 100-110 having maximumelongation of 350% tensile strength od 2.9 Mpa and shall have crack bridging ability upto 2.5mm and shall resist 10 bars of hydrostatic presure and reduce surface temprerature upto 10 degree celsius with 33% ditution of priming coat. Laying of fiber mesh of 0.3mm thickness weave in leno pattern having 45 grm/sqm and pastinf it properly with overlaping of 50mm and allow it to dry, Apply second coat of undiluted coat @ 0.45 ltr/ Sqm . Apply third and final coat undiluted @ 0.45 ltr/sqm complete application to be done by the manufacture of authorised applicator complete all as specified and directed. |
| 23 | Note for item No 22 :-(a) Cleaning of dust, removal for all loose existing bituminous material manually with heat torch gun to get smooth plain finished surface, removing of vegetation/plantaion with no loose material on surface.(b) Conduct ponding test after 7 days, continnue curing of 14 days.(c) All Shifting/ removing of any wire/cable/AC unit/Water tank of any capacity or other any object as per site requirement an re-fixing the same, if needed shall deemed to be included in the quoted rates by the contractor. (d) Removal of any loose/packed items such as mud phuska, terrace tiles, cement screed bed shall be removed and surface shall be made free from depressions before applying treatment to the roof. Quoted rates shall deemed to be includedthis fact into account and no extra payment shall be made on this account. (e) Contractor shall verify availability of the materials in full qty from market before quoting the rates as no extension of time on this ground shall be granted.(f) All the sample/ make for water proofing material mentioned in item shall be got approved from the GE before procuring bulk quantity of material. |
| 24 | Supply only liquid water proofing compoundcomplete all as specified and directed. |
| 25 | S&F in repair for Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture1.40 mm fixed with tinned tacks, or stainless steel wire staples complete all as specified & directed. |
| 26 | S&F 3mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exc 0.50 Sqm in each pane including hacking out old broken glass complete all as specified and directed. |
| 27 | S&F 3mm thick frosted/pin head glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exc 0.50 Sqm in each pane complete all as specified and directed. |
| 28 | S&F 100 mm size butt hinges (as per sample) medium weight, cold rolled mild steel complete all as specified and directed. |
| 29 | S&F aluminiumanodized barrel tower bolts 200 mm of extruded section (as per sample) fixed complete all as specified and directed. |
| 30 | S&F 150 mm size aluminium alloy handles, febricated type extruded section(as per sample), complete all as specified and directed. |
| 31 | S&F in repair forPeg set of Six powder coated fixed with chromium plated brass screws and wooden and plastic cleats(min wt 190 gm) complete all as specified and directed. |
| 32 | S&F for 300 mm long aluminium alloy, sliding door bolt withhasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts complete all as specified and directed |
| 33 | M&L for Brick work with fly ash bricks (Old Size bricks), sub class\"B\" bricksstraight or curved on plan exc 6 mtr mean radius built in CM 1:4 complete all as specified & directed. |
| 34 | M&L for Brick work with fly ash bricks (Old Size bricks),straight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified & directed. |
| 35 | M&L Brick work with fly ash bricks straight or curved on plan to any radius in half thick walls,built in CM 1:4complete all as specified and directed. |
| 36 | M&L for Rendering 10mm thick on fair faces of brick work, concrete sruface in cement mortar (1:6), finished even and smooth without using extra cement complete all as specified and directed. |
| 37 | M&L for Rendering 5mm thick cement plaster on fair faces of brick work, concrete sruface in cement mortar (1:3) as in ceiling finished even and smooth without using extra cement complete all as specified and directed. |
| 38 | M&L for rendering 15 mm thick cemet plster on fair faces of brick work or concrte surfacesin CM 1:4 in two layers(5mm finishing layer over 10mm base layer) finished even and surface without using extra cemen with WPC over finishing layercomplete all as specified and directed.Note: WPC shall be measured and paid seperately) |
| 39 | M&L for rendering 10 mm thick in CM 1:3 in fascia / edging / ceiling of Chajjas,roof projections, drainge etc, making the edges in line, in true shape and finishing the surface without using extra cement complete all as specified and directed. |
| 40 | M&L for cleaning, breaking, loose concrete, changingofcorressive reinforcement with new reinforcement (if required) and filling plain cement concrete 1:1 1/2 :3 type B0 using 12.5mm graded aggregate 75mm using approved bonding chamical(from Fosroc/STP/Sikka/ Dr. Fixit) at places like chajja, sunchades, roof projection, fascia, etc beams, columns etc including necessary scafolding, formwork (upto G+2 floor) etccomplete all as specified and directed. Note :- The cost of scafoldings, formwork, reinforcement etc shall deemed to be included in the quoted rate of item. Reinforcement shall be measured and paid for seperately. |
| 41 | M&L for preparation of new plastered surface of external wall and chajjas,making surface smooth using sand paper, priming the surface with alkali resistance primer paintfor external surface, applying two coats of exterior emulsion (weather coat) paint complete all as specified & directed. |
| 42 | M&L for preparation of new plastered surface of walls and applying three coats of white wash complete all as specified and directed. |
| 43 | M&L for preparation of new plastered surface of ceiling and applying three coats of white wash complete all as specified and directed. |
| 44 | M&L two caot of white wash on surface of wall including preparation of old plastered surface after complete remvoal of existing treatment complete all as specified & directed |
| 45 | M&L two caot of white wash on surface of ceiling including preparation of old plastered surface complete all as specified & directed |
| 46 | M&L for complete removal of old existing treatment including preparation of plaster/unplaster surfaces ofwalls, chajja, fascia etc and applying two coat of exteior emulsion paint (weather coat) over a coa of primer any shade or any colour complete all as specified and directed. |
| 47 | M&L for Cement concretetype C-1, 1:3:6 (using 20mm graded crushedstone aggregate) as in plinth protection and paving 75mm thick laid in slope finished even and fair including making joints not more than 2.5 m (or as directed) and at corner, filled with bitumen 85/25 and sand in ratio 1:2 by weight complete all as specified and directed. |
| 48 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqmbut not exceeding 0.18 sqmin floors and skirting etc set and jointed in neat cement slurry and pointed in coloured cementlaid over 15mm thick screed bed in CM (1:4)including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises all as specified and directed . |
| 49 | M&L for glazed ceramic coloured tiles in vertical surface 450x350x7mm or 450x300x7mm thick set and jointedin neat cement slurry and pointed in white or coloured cement to match over 10mm thick screed bed or bedding layer of mortar in CM 1:4 including dismantling floor, hearth or walls tilling and terrazo topping including cement mortar bedding ( but not backing),rubish off the premises complete all as specified and directed. |
| 50 | M&L for glazed ceramic coloured tiles in vertical surface 450x300x7mm set and jointed (joint free) in neat cement slurry and pointed in white or coloured cement to match over 10mm thick screed bed or bedding layer of mortar in CM 1:4 including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises all as specified and directed . complete all as specified and directed. |
| 51 | M&L green Marble work 18-20mm thick (table rubbed and polished) in cooking plateform,window cill, steps, stair case trade & riser etc in 15 mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of Bhaislana Zebra including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises all as specified and directed . complete all as specified & directed. |
| 52 | Surface dressing not exc. 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 53 | M&L for 80mm thickness M-40 grade Machine pressed precast concrete factory made interlockingpaver block confirming to IS-15658-2006 (topping thickness not less than 5mm thick with white cement and colour pigment non fadable epoxy coating) complete all as specified & directed. |
| 54 | M&L for 100mm thick PCC 1:4:8 typeD-2 (using 40mm graded crushedstone aggregate) as insub bases and pavings etc complete all as specified and directed. |
| 55 | M&L for25mm thick PCC type B-1, 1:2:4 ( using 20mm graded crushedstone aggregate) as in sub floors for laying floor finish complete all as specified and directed. |
| 56 | M&L for PCC 1:4:8 type D-2 (using 40mm graded crushedstone aggregate) as in foundation, filling and mass concretecomplete all as specified and directed. |
| 57 | M&L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc., Brushing neat cement slurry with 3.0kg of cement per sq. meter complete all as specified and directed |
| 58 | M&L for Round chamfering to the edgesof marble/granite slabs not exc 15 mm wide complete all as specified and directed. |
| 59 | M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface broken stone or boulders complete all as specified and directed. |
| 60 | M&L 25-40mm thickSand filling under floors or paving including levelling , watering and consolidationand complete all as specified and directed. |
| 61 | M&L for screed bed or bedding layers of mortar 15 mm thick in CM 1:4 for layingfloor finishes, rough finished surfacecomplete all as specified and directed. |
| 62 | M&L for RCC M-25 ( Nominal mix)as in Slabs supported on walls, beams and columns in floors roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed |
| 63 | M&L for RCC M-25 ( Nominal mix)as infoundations including rafts, footings, foundations beams, plinth beams, basesfor columns and basement slabs etc complete all as specified and directed. |
| 64 | M&L for RCC M-25 ( Nominal mix)as incolumns, pillars, piers, posts and strutsetc complete all as specified and directed. |
| 65 | M&L for RCC M-25 ( Nominal mix)as inbeams, cantilever, bressummers, lintels over 1.50m span complete all as specified and directed. |
| 66 | M&L for RCC M-25 ( Nominal mix)as in Chajja complete all as specified and directed |
| 67 | TMT Bars of 5mm dia in stirrups, spacers and binders, cut to length bent to shape requiredincluding cranking, bindingspirally for hooping for columns hooking ends and bindingwithand including MS wire annealed not less than 0.9 mm dia or securining with clip complete all as specified and directed. |
| 68 | TMT bars 10mm dia and over cut to length, bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not les than 0.9 mm dia or securing with clips quality conforming tocomplete all as specified and directed. |
| 69 | Formwork to soffits of flat surface suspended slabs, floor slabs, landings and similar work not exc 200mm thick (Horizontal or sloping) with fair finished surfaces of concrete complete all as specified and directed. |
| 70 | Formwork to sides of concrete foundation, footing with rough finished surface of concrete complete all as specified and directed. |
| 71 | Formwork to sides of beams and lintels with rough finished surface of concrete complete all as specified and directed. |
| 72 | Formwork to sides of columns with fair finished surface of concrete complete all as specified and directed. |
| 73 | Formwork to edges of concrete in roof slab etc similar work n.exc 20cm wide with rough finished surface of concrete complete all as specified and directed. |
| 74 | S&F15mm bore mild steel tubes medium grade galvanized ISI marked with all fittings, short pieces and fixed to walls, floor, ceiling etc complete all as specified and directed. |
| 75 | Refixing of old steel tubing 15 mm medium grade galvanized ISI marked with new all fittings short pieces and fixed complete to walls, floor etc complete all as specified and directed. |
| 76 | M&L for cutting chases, pinning in brick work,making good to facing where required, pointing in CM 1:3, cutting n.exc. 10cm in girth complete all as specified and directed. |
| 77 | S&F20mm bore tubes medium grade galvanized ISI marked with all fittings, short pieces and fixed to walls, floor, ceiling etc complete all as specified and directed. |
| 78 | Refixing of old steel tubing 20 mm medium grade galvanized ISI marked with new all fittings short pieces and fixed complete to walls, floor etc all as specified |
| 79 | S&F in repair 15mm bore dia angle valve / stop valve cast copper alloy capston head chromium plated (as per sample), fancy type ISI marked with crutch or butter fly handles screwed down, screwed for iron pipe complete all as specified and directed. |
| 80 | S&F Stop valve concealed cast copper alloy (ISI Markd) fancy type, chromium plated with long shank and cup (concealed type) screwed down high pressure with crutch lever handle screwed both ends for iron pipe 15mm bore dia fixed in repair, complete all as specified and directed. |
| 81 | S&F in repairbib taps for 15 mm bore pipe, cast copper alloy fancy type chromium platedcomplete all as specified & directed. |
| 82 | S&Fcounter type Vitreous china wash basin, white flat back, size 550 x 400 mm (as per sample), brackets, CP waste coupling and cutting for and pinning in ends of brackets or errecting standincluding 32 mm diawaste pipe fixed in repair including waste copling 32mm size full thread, complete all as specified and directed. |
| 83 | S&F 15mm bore pillar cock fancy swan neck type, screwed down high pressure crutch lever handle with or without letters hot or cold with long screwed shank and fly nuts screwed for iron pipe ISI marked fixed in repairs complete all as specified & directed. |
| 84 | S&F in repairtowel rail, brass, CP 600 mm long 20mm dia pipe of 1mm thick complete all as specified and directed. |
| 85 | S&F in repairPVC shelf of PTMT fixed with and including chromium plated brass screws and wooden and plastic cleats ( min wt 300 gms) complete all as specified & directed. |
| 86 | S&F in repairbrass CP Shower rose with or without swivel joints (any size) including fixing to steel pipe or union complete all as specified & directed. |
| 87 | S&F in repair glass shelf assembly consisting of 5.5mm thick sheet glass 12cm wide (as per sample) with chromium plated brackets double guard and railing 60cm long, complete all as specified and directed. |
| 88 | S&F in repair600 mm x 450 mm bevelled edge mirror of selected quality glass mounted on 6 mm thick AC building board or BWP commercial plywood and fixed to wooden plugs/PVC rawl plug with chromium plated brass screws and cup washers complete all as specified and directed. |
| 89 | S&F in repair Vitreous China squatting pan of orissa pattern, size 580x440mm white with CI ‘P’ or ‘S’ trap, front or back inlet and foot rests, any pattern(including fixingofflush pipe) including provision of cement concrete bedding, in repair complete all as specified & directed. |
| 90 | S&F Health foucet 8mm dia 1.20m stainless steel flexible hose with wall hook and making connection including taking out existing health foucet of any description complete all as specified & directed. |
| 91 | S&F in repairs Vitreous china wash down water closet pan pedestal pattern , white (excluding supply of flushing cistern and flush pipes, but including fixing thereof),including making connections to trap, and to flush pipe incl plastic seat and cover ( As per sample ) with stainless steel or aluminised hinging device and health foucet/jet spray complete all as specified and directed. |
| 92 | S&F in repair Vitreous china bowl urinal half stall type, white complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing flush pipe, grating and union for discharge pipe including providing and fixing of PTMT urinal spreader with 15mm dia pipe, complete all as specified and directed. |
| 93 | PCC 1:5:10 type E-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete (sunken floors etc) including demolition of PCC complete all as specified. |
| 94 | Rendering 15mm thick on brick work or concrete surfaces in CM 1:4 mixed with water proofing compound to sunken portion with proper slope towards outside, finishing cement concrete or brick work surface even and smooth using extra cement, provide 90 micron polythene film duly applying bitumen coating @ 3.00 Kg/Sqm complete all as specified and directed. Note: WPC shall measured and paid for separately. |
| 95 | S&F in repair10 litre capacity PVC valveless, low level, synphonic action type, flushing cistern, with inlet, ball valve, float valve, handle including brackets including 32mm dia PVC flush pipe of suitable size and making necessary connections to water supply pipe line and jointing to WC,complete all as specified and directed. |
| 96 | S&F in repairPVC connection 15mm size with PTMT nuts of length 450mm,complete all as specified and directed. |
| 97 | Rotational moulded polyethlene water storage tanks of capacity exc 500 litres three layers(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete including 20mm dia ball brass valve high pressure with polythene float and dismantling of existing PVC/RCC tank of any capacity complete all as specified & directed. |
| 98 | S&F 20 mm size gun metal globe or gate valves with iron wheel head, screwed both end for iron pipe and fixedcast copper chromium plated fancy type alloy ISI marked with crutch or butter fly handles screwed down screwed for iron pipe of 20mm bore complete all as specified and directed. |
| 99 | S&F in repair corner glass shelf assembly (as per sample) consisting of 5.5mm thick sheet glass size not less then 300x300x70mm with chromium plated brackets double guard and railing complete all as specified and directed. |
| 100 | 110mm bore dia PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls with clamps, complete all as specified and directed. |
| 101 | S&F in repair 75mm bore dia PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls with clamps, complete all as specified and directed. |
| 102 | S&F in repair 110mm bore dia PVC (SWR) reducers, complete all as specified and directed. |
| 103 | S&F in repair 110mm bore dia PVC (SWR) branch piece, single (single Y) equal or unequal with parrallel branches fitted with oval access doors, fixed in repairs complete all as specified and directed. |
| 104 | S&F in repair 110mm bore dia PVC (SWR) bends,any radius (larger bore measured), complete all as specified and directed. |
| 105 | S&F in repair 75mm bore dia PVC (SWR) bends,any radius (larger bore measured), complete all as specified and directed. |
| 106 | S&F in repair cast iron 75mm bore Branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, fitted with ovel access doors, fixed in repair complete all as specified and directed. |
| 107 | S&F in repair 75mm bore pipe PVC (SWR) vent cowl, fixed in repair, complete all as specified and directed. |
| 108 | S&F in PVC floor trap 75mm with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1 with CP grating with or without hole for waste pipe complete all as specified and directed. |
| 109 | S&F Cast iron soil, waste and vent pipes, sand cast, 75mm bore in any length with or without ears with cement joints, as in floor with all fittings complete all as specified and directed |
| 110 | S&F 50mm bore cast iron soil, waste and vent pipes, sand cast, in any length with or without ears fixed to walls with clamps and cement jointcomplete all as specified and directed. |
| 111 | S&F 100 mm boreCast iron bends (any radius) diminishing pieces or tapers (larger bore measured) with ovel asses door complete all as specified and directed. |
| 112 | S&F in repair cast iron 100mm bore Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, fitted with ovel access doors complete all as specified and directed. |
| 113 | S&F in repairs 75mm diaCast iron bends (any radius) diminishing pieces or tapers (larger bore measured) complete all as specified and directed. |
| 114 | S&F Cast iron floor trap 75mm with grating including jointing to waste pipe fixed in cement concrete 1:2:4 typeB-1 with CP grating with ot without hole for waste pipe complete all as specified and directed. |
| 115 | S&F Cast iron cowl of 50mm bore complete all as specified and directed. |
| 116 | M&L for preparation of new steel or steel based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primercomplete all as specified and as directed. |
| 117 | M&Ltwo coat synthetic enamel paint of old steel or steel based surfaces steel based surfaces of any description over 10 cm width or girth including preparation of surfaces, complete all as specified and as directed. |
| 118 | M & L preparation of old wood or wood based surfaces of any descriptionover 10 cm width or girth and applying two coats of synthetic enamelpaint complete all as specified & directed. |
| 119 | RCC NP3 150mm diameter pipes laid on 150mm thick PCC cradle 1:4:8 bed with excvation in any type of soil including manholes/ drop manhole of standard size made of brick masonary/RCC/Precast RCC with SFRC ventilting cover and frame including all items and activites to execute and make sewer line funtional for depth 0.7m - 1.65m |
| 120 | Soakage wells excavation in any type of soil, foundation in PCC 1:3:6 walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonary in CM, RCC cover slab in M-25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.4M dia x 4.5M effective depth |
| 121 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including unscrewing from board fitting and fixturesuch as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody for reuse if serviceable or for taking credit and making good disturbed surfaces of walls, floors, etc with cement mortar and finishes to match existing surface complete all as specified and directed. |
| 122 | M&L for point wiringusing 3x1.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade (Phase, neutral and earth wire) with proper colour coding drawn through and incl PVC rigid concealed conduit medium grade (ISI Marked) of dia not less than 20mm and 1.6mm thick and connected to common earth dolly with 1.2mm thick CI/GI pressed steel sunken boxes of adequate size,3mm thick plastic laminated sheet cover fixed with brass screws including cutting chases grooves for concealed wiring for light/fan/bell point controlled by one switch and making good (in CM 1:4) the surface as per existing complete all as specified and directed. Note: 1) Conduit shall be fixed on surface/ceiling with necessay saddles where concealing of conduit is not feasible. |
| 123 | All as per Ser item No 121 but for one5/6 Amp socket outlet points on independentboard controlled by one switch. |
| 124 | M&L for point wiringusing 3x1.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade (Phase, neutral and earth wire) with proper colour coding drawn through and incl PVC rigid concealed conduit medium grade (ISI Marked) of dia not less than 20mm and 1.5mm thick and connected to common earth dolly with and including 1.2mm thick GI/MS pressed steel sunken box of pressed steel sunken boxes of adequate size,3mm thick plastic laminated sheet cover fixed with brass screws including cutting chases grooves for concealed wiring for light/fan/bell point controlled by one switch wiring for light/fan/bell point controlled by one switch and making good (in CM 1:4) the surface as per existing complete all as specified and directed. Note:- 1) Conduit shall be fixed on surface/ceiling with necessay saddles where concealing of conduit is not feasible.2) Rate of supplying and fixing modular GI/MS pressed sunken box with support frame deemed to be included in the quoted rates. |
| 125 | All as per Ser item No 123 but for one5/6 Amp socket outlet point on same board controlled by one switch. |
| 126 | All as per Srl item No 123 here-in-before for one 15/16 amp socket point with 3x2.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor. |
| 127 | S&F switch piano flush button single pole one way 5/6 Amp 240 volts complete all as specified and as directed. |
| 128 | S&F socket outlet 2 in 1, 3 pin, 5/6 Amps, flush type with shutters, 240 volts complete all as specified and as directed. |
| 129 | S&F socket outlet 2 in 1, 6 pin, 6/16 Amp flush type, 240 volts complete all as specified and as directed. |
| 130 | S&F switch 15/16 Amps, flush type, 240 volts complete all as specified and as directed. |
| 131 | S&F ceiling rose PVC/polycarbonate, insulated body surface Bakelite 65mm dia three terminals. |
| 132 | S&FLamp holder jumbo modular type, PVC/Polycarbonate type with back plate suitable for batten fitting including 15 W LED Lamp complete all as specified. |
| 133 | S&F LED Lamp 12 watt 230 volts retfrofit suitable of any type lamp holder complete all as specified. |
| 134 | S&F 20W surface / wall mounted box type batten LED fitting having polycarbonate housing and diffuser and integrated electronic driver with system luminous efficacy ≥ 100 lumens/Watt operating voltage 140V-240V complete with all accessories internally prewired and including connecting up with suitable size flexible copper conductor cable from ceiling rose to connector of LED fitting complete all as specified and directed. |
| 135 | All as per ser item No 133 but for 10 W LED batten fitting 2 feet long. |
| 136 | S&F LED wall security lights of 35 Watthaving pressure die cast aluminium housing with system lumens efficacy≥100 lumen/W,IP65 protection, IK07 rating,inbuilt electronic driver withPF>0.95 incl GI bracket of suitable dia bend to shape and fixed to wall by means of clamps or nuts bolts and connecting up with three core twisted flexible copper conductor cable complete all as specified and directed. |
| 137 | S & F for sub Main Wiring with two single core FRLS PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x4 Sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 4 Sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in and including suitable size concealed rigid medium grade PVC conduit not less than 25mm dia 1.5mm thickwith all accessories incl cutting chases on wall andmaking good to the disturbed surface of wall/floor with cement mortar 1:4 and finishes to match existing surface complete all as specified and directed. |
| 138 | Disconneting & taking down exhaust fan any type/ cap refixing to the same/other location after replacing rubber reel, fixing bolts and nuts with lock pins, connectors complete all as specified and directed. |
| 139 | Disconneting & taking down geyser any type/capacity complete,refixing to the same/other location with all connected accessories afer cleaning replacing anchor bolts complete all as specified and directed. |
| 140 | MCB DB, SPN, 4 way sheet metal enclosures double door 230 V AC, 50 Hz AC with IP 43 and IK 09 rating having fully insulated copper busbar, neutral bar, earth bar and cable ties for cable management including polyuthrene gasket complete complete in all respect flushed in wallincluding cutting chases on wall for taking out old unsv DB and fixing of new DB and making good disturbed surface of wall with cement mortar 1:4 and finishes to match exisiting surface, complete all as specified and directed. |
| 141 | S&F MCB SP 240V, 50Hz of rating6 to 32 Amp, \"B\" curve using suitable size copper thimbles complete all as specified and directed. |
| 142 | S&F MCB SPN 240V, 50Hz of rating 40 Amp, \"B\" curve using suitable size copper thimbles complete all as specified and directed. |
| 143 | S&F MCB SPN 240V, 50Hz, 10 KA of rating32 Amp\"C\" series complete all as specified and directed. |
| 144 | S&F MCB SP 240V, 50Hz, 10 KA of rating5 to 32 Amp\"C\" series complete all as specified and directed. |
| 145 | S&F in replacement LED mirror light 1x10 Watt 2\" feet prewired with all accessories including lamp complete with all accessories internely pre wired and including connection up with 3 core twisted flexible copper conductor cable of suitable size complete all as specified and directed. |
| 146 | S&F in repalcement surface mounted, bulk head LED luminaire 10 W with and integrated electronic driver with system luminous efficacy ≥ 100 lumens/Watt operating voltage 140V-240V, IP 65 protectioncomplete with all accessories internally prewired and including connecting up with suitable size flexible copper conductor cable from ceiling rose to connector of LED fitting complete all as specified and directed. |
| 147 | S&F in repalcement of intenso LXS LED Batten 20 watt of size not less than 3\"7\", 6500 K, 230 volts, PF-0.95, CRI-80, life 25000 burning hours, wall mounted complete with all accessories internely pre wired and including connecting up with 3 core twisted flexible copper conductor cable of suitable size complete all as specified and directed. |
| 148 | S&F heavy duty metallic exhaust fan AC single phase 230/240 Volt of size 230mm sweep with louver\"s incluidng grouting nut bolt and making the suitable hole of suitable size by breaking the existing wall and making good the disturb surface by plastering and matching with existing specifiction with suitable finishes and connectiong up including privision of flexible copper wire 3 core of suitable size from ceiling /PVC connector to exhust fan complete all all as specified and directed. |
| 149 | Supply, laying, jointing and testing ofXLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts gradewith aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 10 Sqmm 2 core, including taking down old, complete, all as specified and directed.Note : All the cable entires should be through proper metallic cable gland. |
| 150 | M&L for sand filling in trenches as cushion to under ground cables 8 cm thick before laying the cable and 15 cm thick when cables are laid and tested complete all as specified and directed. Note: Only punned thickness i.e 18cm shall be measured and paid. |
| 151 | S&F for galvanised GI tubing light grade 40mm bore with fittings, laid in trenches including all fittingscomplete all as specified and as directed. |
| 152 | M&L for well burned bricks, laid flat (old size) sub class \"B\" designation 75 for cable protection complete all as specified and directed. |
| 153 | Earthing complete in repair with galvanized steel earth plate electrode60cm x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead GI wire 4mm dia by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvd iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of2009.Note : RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmmin lieu of CI cover. |