Tender For Special Repairs To Bldg No P- 468 And P- 469 Dhruva Enclave At Cdm Secunderabad Under Age B/R (N) Ii Of Ge (N) Secunderbad.; 1 Demolition of cement concrete in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work otherwise specifically provided for roof treatment complete all as specifiedand directed. 2 M & L for 25 mm thick PCC (1:2:4) Type B-0 by using 12.50mm graded stone aggregate as in roof where require over slabs and finishing the exposed surfaces fair even without using extra cement complete all as specified and directed 3 M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed 4 M & L for water proof plastering 10mm thick on fair faces of brick work or concrete or roof terrace surfacesin CM 1:3 with WPC @3% by weight of cement including finishing the surfaces all as specified and directed. 5 Supply only Integral waterproofing compound for waterproof plastering complete all as specifiedand directed. 6 M & L for priming the plastered roof surfaces with bituminous primer @ 0.3 Kg/Sqm and laying the APPmodified water proofing membrane as perIS 16540-2017/ IS 16532-2017mineral finish, 3 mm thick and weighing not less than 3.8 Kg/Sqmreinforced with non woven Polyester /HMHDPE matt black finished over compatible primer/bonding bitumen with 100 mm overlap after necessarypreparation of surface complete as per manufacturer’s instructions with bituminous aluminium paint on top @ 0.1Ltr/Sqm complete all as specified. 7 Demolition of Concrete in ground floors and pavings n exc 15 cm thicknesscomplete all as specified. 8 M & L for Cement concrete type C-2, 1:5:10 (using 40mm graded aggregate) 50 mm thickness as in sub base complete all as specified. 9 M & L for Cement concrete type C-2, 1:3:6 (using 40mm graded aggregate) 75 mm thickness as in plinth protection complete all as specified. 10 M & L for Forming 12 mm thick expansion joints filled upto full depth with pre-formed bituminous filler and top 30mm primed and sealed with sealingcompound, Grade ‘A’complete all as specified and directed. 11 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing servicable tiles to store and rubbish off the permises complete all as specified. 12 M & L for Virified Ceramic tiles Dark shade double charged 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles over and including 15 mmthick screed bed in CM 1:4 all as specified and directed. 13 M & L for Virified Ceramic tiles Dark shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles over and including 10 mmthick rendering in CM 1:3 all as specified and directed. 14 M & L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tileexceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed incoloured cement to match the tiles over and including 15 mmthick screed bed in CM 1:4 all as specified and directed. 15 M & L for dark shade Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles over and including 15 mmthick screed bed in CM 1:4 all as specified and directed. 16 M & L for dark shade Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles over and including 10 mmthick rendering in CM 1:3 all as specified and directed. 17 M & L forcoloured Glazed ceramic tiles in vertical surface 300 x 600 x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including PVC tile beading of matching colour as and where requiredover 10 mm thick backing coat in CM (1:3) complete all as specified and directed. 18 Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc laid in any mortar complete all as specified and directed. 19 M & L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, flooring/tread of stairs& riser of steps in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete over and including 20 mmthick screed bed in CM 1:6 all as specified and directed. 20 Labour only for full round moulding to 18 to 20mm thick granite slab complete all as directed. 21 Demolition of RCC Concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified . 22 Providing cement concrete Type B0 1:2:4 (12.5mm Aggregate) in roof kerbs or mud stops, watertank platform as complete all as specified . 23 Taking down Chowkhats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 Sqm each complete all as specified and directed. 24 Taking down Chowkhats or frames with shutters (without taking off shutters from the frames) but exc 1.5 Sqm and n exc 4 Sqm each complete all as specified and directed. 25 Taking down shutters of any description n exc 1 Sqm each complete all as specified and directed. 26 Taking down shutters of any description exc 1 Sqm and n exc 2 Sqm each complete all as specified and directed. 27 S & F Powder coated anodised aluminium window and ventilator shutters, side hung/ sliding type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed.Note: Glass pane and wire mesh shall be measured and paid seperatly 28 S & F Powder coated anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed.Note: Glass pane and wire mesh shall be measured and paid seperatly 29 S & F powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. 30 S & F 4.8 mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.5 sqm complete all as specified and directed. 31 S & F 5 mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed. 32 S & F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS:1868 with minimum anodic coating of grade AC 15) of approved design/ pattern, with approved standard section and fixed to the existing window frame with CP Brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size of fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engr-in-Charge. 33 S & F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. 34 S & F in repairs 35 mm thick flush shutters, solid core construction, with decorative face veneer with lipping/frame to match on both sides complete all as directed by Engr-in- Charge. 35 S & F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 Kg/Cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being teRmite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately)Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable.Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified. 36 S & FProviding and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 Kg/Cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being teRmite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately). 37 S & F II nd class hardwood 35mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats 38 All as per Item No 35 above except size of the frame/chowkhat is 65 X125 mm and double extuded section 39 S & F in repair Aluminium Door closerhydraulically regulated designation No.3,universal type ,suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg. 40 S&F in repair Stainless steel Handle of 150 mm long fixed with Self Tapping screws complete all as specified and directed. 41 S & F in repair Stainless steel butt hinges 100mm complete all as specified and directed.NOTE :- All screws shall be self tapping chrome plated and length ofscrew not less 38 mm. 42 S & F in repair Stainless steel Tower Bolt of 200 mm longfixed with Self Tapping screws complete all as specified and directed. 43 S & F in repair Stainless steel sliding door bolts, plate type,bright bolt not less than 12mm dia with and incl a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate 250 mm long (selected quality as approved) complete all as specified and directed. 44 S&F in repair floor door stopper of Stainless steel body and tongue 135 mm anodised with hard drawn steel spring fixed in floor complete all as specified and directed. 45 S & F in repair 18mm thick UV Coated Prelaminated MDF Board of decorative type on both sides fixed with screws to walls by inserting rawl plugs in the wall/ column surfaces. 46 Extra over rates of block board or veneered particle board for external teak wood lipping, 6mm thick fixed with nails complete all as specified and directed. 47 Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed. 48 S & F 12 mm thick plywood BWR type fixed with screws to timber frame work complete all as specified and directed. 49 S & F 18 mm thick plywood BWR type fixed with screws to timber frame work complete all as specified and directed. 50 M & L for 0.9 mm thick colour/ white laminated sheet fixed to wooden surface with glue complete all as specified and directed. 51 S & F 40mm flap width continuous (piano) hinges, mild steel, bright finish or electro-galvanised 52 S & F in repairs stainless steel heavy duty tubular curtain rod of 20mm dia (weighing not less than 1.03Kg/Rm) and fixed brackets complete all as specified and as directed. Note : Brackets will be measured and paid under separate item 53 S &Fstainless steel brackets/end globes designer type suitable for 20mm dia stainless steel heavy duty curtain rod as per Srl. Item No.52 here-in-before, fixed to wall with PVCrawl plug and brass screws etc., complete all as specified and as directed. 54 S & F 200mm long SS decorative handle fixed with screw complete all as specified and directed. 55 S & F 200mm long SS decorative hinge for cabinets auto closed concealed type complete all as specified and directed. 56 S & F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles confoRming to Fe-290 Gde-E-165 all as specified 57 M & L for providing, cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate as in copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, hold fast blocks.- 58 S & F in replacement stainless steel plate rack of size 609mm X 914mm X 254 mm complete all as specified and directed.Make:Hindustan or equivalent as approved 59 S & F stainless steel auto lid waste bin 5 litre capcity complete all as specified and directed. 60 S & F in repairs 600mm long stainless steelwall hook rail set for hanging clothes complete all as specified and directed. 61 S & F Vitreous China wash down water closet pan, divine P Trap 180 mm (pedestal pattern),wall hung type (one piece set) white (incl fixing bolts, inbuilt flushing cistern and flush pipe) incl seat cover complete all as specified and directed.Make : Cat No: VGS-WHT-81953UF of Jaquar or equivalent in ROCA/KOHLER . 62 S & F in repair CP health faucet with 01 Mtr tube and hook complete all as specified and directed.Make : Cat No: K-12925IN-CP of Kohler or equivalent in ROCA/Jaquar . 63 S & F in repairs WHB white of size 565 x 450 x 195 mm or required size as approved and complete all as specified and as directed.Make : Cat No: CNS-WHT-811 of Jaquar or equivalent in ROCA/KOHLER 64 S & F in repairs 15 mm bore Fancy type pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all asspecified and directed Make: Cat No. FUS-CHR-29023B of Jaquar or equivalent in ROCA/KOHLER 65 S & F in repairs 32mm bore brass CP bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed Complete all as specified and directed. 66 S & F in repairs PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed. 67 S & F in repair bathroom mirror cabinet made up of rust proof aluminium with aMirror-front door and reflective mirrored interiorof size 380 X 610 mm fancy type complete all as specified and as directed .Make :K-81144-DA1 Maxtow of Kohler or equivalent . 68 S & F in repairs bib tap fancy type chromium plated, crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all asspecified and directed Make : Cat No. FUS-CHR-29037 of Jaquar or equivalent in ROCA/KOHLER 69 S & F in repairs wall mixer with provision of over head shower with 115mm long bend pipe on upper side connecting legs and wall flanges complete all as specified and directed.Make :- Cat No FUS-CHR-29273UPR of Jaquar or equivalent in ROCA/KOHLER 70 S & Fin repair 150 X150 mm overhead shower completed all as specified and directedMake :- Cat No OHS-CHR-1605 of Jaquar or equivalent in ROCA/KOHLER 71 S & F in repairs Stop/angle valves fancy type 15mm dia, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed. Make : Cat No:FUS-CHR-29053 of Jaquar or equivalent in ROCA/KOHLER 72 S & F in repairs 15mm size two way bib tap fancy type chromium plated, crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all asspecified and directed .Make: cat no: FUS CHR 29041of Jaquar or equivalent in ROCA/KOHLERas approved. 73 S & F in repairs brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed.Make: Cat Part No ACN-CHR-1111SM of Jaquar or Equivalent in Roca/Kohler 74 S & F in repairs Soap dish, vitreous China white, approximate size 160x 160x90mm embedded in the wall complete all as specified and directed.Make: CatPart No ACN-CHR-1131N of Jaquar or Equivalent in Roca/Kohler 75 S & F in repairs rotational moulded polyethylenewater storage tank 3 layer white colour waterr tank , non- toxic effect, algea formation protection (made from Virgin grade of polyetjylene material which is duly stablized with anti-oxidentPlastic) of capacity 1000 litres, (cylindrical vertical one piece moulded with closed top), the internal and external surfaces of tanks are smooth, clean and free from any hidden internal defects, hoisted and fixed in position including S & F necessary GI fittings, inlet/outlet washout, overflow pieces long nipples, checknuts & washer, 20mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 210gms) and stop valves for 20mm bore pipe, cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both endsetc complete including dismantling existing water tank all as specified and directed.MAKE :- Cat No. HSWS-0100-01-Pure of M/s SINTEX 76 All as per Item No 75 above except capacity of tank 500 LitresMAKE :- Cat No. HSWS-0050-02-Pure of M/s SINTEX 77 S & F in repairs sinks without drainage board made of stainless steel l mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 405mm x 460mmx 203mm, bowl size 405mm x 354mm x 203mmincl waste pipe and waste coupling complete all as specified and directed. 78 S & F in repairs 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. 79 S & F in repairs 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. 80 S & F in repairs 110 mm bore PVC (SWR) bends any radius complete all as specified and directed 81 S & F in repairs 75 mm bore PVC (SWR) bends any radius complete all as specified and directed 82 S & F in repairs 110 mm bore PVC (SWR) door bends any radius complete all as specified and directed 83 S & F in repairs 75 mm bore PVC (SWR) door bends any radius complete all as specified and directed 84 S & F in repairs 75 mm bore PVC (SWR) T junction single, (Single T) equal or unequal any radius complete all as specified and directed 85 S & F in repairs 110 mm bore PVC (SWR) T junction single, (Single T) equal or unequal any radius complete all as specified and directed 86 S & F PVC (SWR) floor trap 75mm dia, plain withSS grating including jointing with solvent cement complete all as specified and directed 87 S & F in repairs Grating doom 100mm dia of PTMT/ SS. (Minimum weight 85gms) complete all as specified and directed 88 S & F 16 mm CPVC pipes SDR 11& Plain CPVC SDR 11fittings in trenches complete all as specified and directed 89 S & F 20 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and directed 90 S & F 25 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and directed 91 Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed 92 Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed 93 Taking up or down 25 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed 94 S & F sheet glass shelf assembly consisting of 5.50mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing fixed in repairs complete all as specified and directed 95 Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed 96 Dismantling wrought iron or mild steel work of any description complete all as specified and directed 97 S & F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confoRming to I. S.1161- 1979 grade St.-240 complete all as specified and directed 98 S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed 99 M & L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement. 100 M & L for Post Construction Anti termite treatment Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc in apron complete all as specified and directed 101 M & L for Post Construction Anti termite treatment of soil under existing floorsusing emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with CM 1:2to match the existing floors complete all as specified and directed 102 M & L for Post Construction Anti termite treatment ofvoids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with CM 1:2to match the existing floors complete all as specified and directed 103 M & L for Post Construction Anti termite treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and directed 104 Taking down cement plaster on brick or stone walls/ceiling, etc. including raking out joints, hacking for key, scrubbing down with water, etc. 105 M & L for 15mm thick Rendering on fair faces of brick work or concrete surfaces of walls in CM1:4 with WPC @3% by weight of cement including finishing the surfaces all as specified and directed. 106 M & L for 10mm thick Rendering on fair faces of brick work or concrete surfaces of wall in CM1:6 all as specified and directed. 107 M & L for 5mm thick Rendering on fair faces of brick work or concrete surfaces of ceiling in CM1:3 all as specified and directed. 108 M & L for preparartion of new wall surfaces & applyingtwo coat of distemper oilemulsion over a coat of alkali resistant primer over 3mm thick wall care putty in two layer complete all as directed. 109 M & L for preparation of newwall surfaces &applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 Sqm over wall/concrete surfaces of any height complete all as directed. 110 M & L for preparartion of new ceiling surfaces & applying two coats of OBD over a coat of primer complete all as specified and directed. 111 M & L for Complete removal of existing treatment of external wall surfaces &applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 Sqm over wall/concrete surfaces of any height complete all as directed. 112 M & L for Complete removal of existing treatmentof old plastered internal surfaces of wall and applying two coats of OBD over a coat of primer including 3mm thick wall care putty in two layers complete all as specified and directed.. 113 M & L for Complete removal of existing treatmentof old plastered ceiling surfaces and applying two coats of OBD over a coat of primer complete all as specified and directed.. 114 M & L for Preparing old steel surfaces of any description exc 10cm width or grith and applying one coat of synthetic enamel paintcomplete all as specified and directed. 115 M & L for Preparing old wooden surfaces of any description exc 10cm width or grith and applying one coat of synthetic enamel paintcomplete all as specified and directed. 116 M & L for Preparing new wooden surfaces of any description exc 10cm width or grith and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. 117 M & L for Preparing new steel surfaces of any description exc 10cm width or grith and applying two coat of synthetic enamel paint over a coat of aluminium red oxide primer complete all as specified and directed. 118 S & F in repair vitreous China squatting pan Orissa pattern size 580 x 440mm white with integral foot rest (excluding flushing cistern and flush pipe), including P-trap (PVC) 100 mm dia., connection to flushing pipe, anti-syphonage pipe complete including making good to floor complete all as specified and directed.Make: Cera/Prayag/Johnson Pedder. 119 S & F in repair 10 ltr capacity PVC valveless syphonic action type flushing cistern low level white with inlet ball valve float and handle including brackets and PVC flushing pipe of polyethylene of low or high density or PVC 32mm dia complete all as specified and directed.Make: Cera/Prayag/Johnson Pedder. 120 S & F in repairs CP Stop/angle valves fancy type 15mm dia, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed.Make: Cera/Prayag/Johnson Pedder. 121 S & F in repairs 15mm bib tap fancy type chromium plated, crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all asspecified and directed 122 S & Flooking mirror of size 600mm x 450mm x 5 mm thick bevelled edge mirror of selected quality glass, itched designed corners, fixed to wall with 12mm dia spacers at each corner complete all as specified and as directed 123 Demolotion of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed 124 M & L for brick work with fly ash bricks straight or curved on plan exceeding 6 metre mean radius with old size bricks built in CM 1:6 complete all as specified and as directed. 125 Taking down existing unserviceable point wiring of any description/type/ size of light/ fan/tube/power/two way/bell point etc on TW batten/conduit includingremovalof batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified. 126 Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as per existing at site including making good the disturbed surfaces to match with the existing finishes all as specified. 127 M & L for Point wiring on concealed conduit with 1.5 Sq mm FRLS copper conductor single core PVC insulated sheathed 1100 V multistranded drawn through conduit and including rigid 20 MM PVC conduit and conduit accessories of suitable dia medium grade and modular accessories including fixing/grouting sunken/ surface along with modular flush box of sutiable thickness covered with suitable modular cover plate including running up of 1.5 Sq mm FRLS copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly for fixing the switches/ sockets/ regulators etc all as specified for One light/fan/bell point controlled by one, one way switch 5 Amps SPNote : Rate of Modular flush box & Modular cover plates and Cutting chases shall be inclusive of rate quoted by the contractor. 128 All as Sl Item No 3 above but One 2/3 pin 5 Amps switch socket outlet point controlled by one switch on the same board . 129 All as Sl Item No 3 above but One 3 Pin 5 Amps switch socket Independt board. 130 Description all as per item No 3 here-in-before but using 2.5 Sq mm FRLS single core copper conductor cable of multistranded PVC insulated unsheathed 1100 Volts grade for 6/16A Amps switch socket combination point including running of 2.5 Sq mm FRLS copper conductor PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly. 131 S & F Modular switch 1 way 10 A, 1 Module capacity 230 volts. 132 S & F Modular switch 1 way 16 A, 1 Module capacity 230 volts. 133 S & F Modular Bell push 10 A, 1 Module capacity 230 Volts. 134 S & F Modular Socket, 6A - 2/3 combined 2 module of capacity 230 volts. 135 S & F Modular Socket outlet multipurpose 3 pin 6/16A Amp 2 module of capacity 230 volts. 136 S & F Call bell ding dong complete all as specified and directed by Engg in Charge. 137 S& F sheet steel enclosure fitted with plug and socket of AC Box with MCB 20 Amps complete all as specified and directed by Engg in Charge. 138 S & F Modular ceiling fan regulator 5 stepped type 2 Moduleheavy duty suitable to work on 230 volts complete all as specified. 139 S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified. 140 S and F sheet metal enclosure MCBDB SPN 12 way with suitable rated bus bar 240 Volts double door with magnetic locking system complete all as specified. 141 Supply, fix, connecting and testing MCB, Single Pole (SP), 6-32 Amps, 240 volts of rupturing capacity 10 KA, C series complete all as specified and as directed. 142 Supply, fix, connecting and testing MCB, Single Pole Neutral (SPN), 40 to 63 Amps, 240 volts of rupturing capacity 10 KA, C series complete all as specified and as directed. 143 S & F in replacement of wall mounted batten type LED light of 20/22 watts with aluminium extruded batten and system lumens of 2200 lm minimum with IP & surge protection alongwith driver efficiency >85% and power factor >0.95 , colour rendering index CRI>80 along with integrated driver completeand connecting to the point wiring with necessary flexible copper conductor of multistrand three core of suitable length from fitting to the ceiling roseall as directed by Engineer-in-charge. 144 S & F in replacement of wall mounted batten type LED light of 12 watts with aluminium extruded batten and system lumens of 1200 lm minimum with IP & surge protection alongwith driver efficiency >85% and power factor >0.95 , colour rendering index CRI>80 along with integrated driver completeand connecting to the point wiring with necessary flexible copper conductor of multistrand three core of suitable length from fitting to the ceiling roseall as directed by Engineer-in-charge. 145 Supply and fixing in replacement of surface round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engg-in-Charge 146 S & F in replacement of Decorative wall mounted fixture of 09 watts LED including LED 09 watts lamp complete with all accessories all as specified and directed by Engg-in-Charge. 147 S & F in replacement of LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed 148 S & F in replacement of Security Lights of 1x30 watt LED light with high power LED and unique peanut lens to ensure uniform distribution with suitable pipe bracket 32 mm dia 0.60 Mtr length fixed on wall with suitable flat iron clamps and nut bolts including provision of 1.5 sqmm 3 core multistranded copper conductor cable from light fitting to junction box complete all as specified and directed by Engg-in-Charge. 149 M & L for Submain wiring with two single core 4 Sq mm FRLS PVC insulated copper conductor multistranded 1100 Volts grade drawn through andincluding rigidPVC conduit and concealed conduit accessories of suitable dia medium grade including running up of one runs of4 Sq mm FRLS copper conductor multistranded PVC insulated cable as earth continuity conductor along the wiring and connected to the common earth dolly completeincludingremovingtheexistingunserviceablesubmain wiringandmakinggood thedisturbed surfaceto match with the existing all as specified.Note:-two runs of cable, one run of earth contuinity conductor and one run of conduit shall bemeasured and paid as one unit length. 150 M & L for Submain wiring with two single core 6 Sq mm FRLS PVC insulated copper conductor multistranded 1100 Volts grade drawn through andincluding rigidPVC conduit and concealed conduit accessories of suitable dia medium grade including running up of one runs of6 Sq mm FRLS copper conductor multistranded PVC insulated cable as earth continuity conductor along the wiring and connected to the common earth dolly completeincludingremovingtheexistingunserviceablesubmain wiringandmakinggood thedisturbed surfaceto match with the existing all as specified.Note:-two runs of cable, one run of earth contuinity conductor and one run of conduit shall bemeasured and paid as one unit length. 151 M & L for Submain wiring with two single core 10 Sq mm FRLS PVC insulated copper conductor multistranded 1100 Volts grade drawn through andincluding rigidPVC conduit and concealed conduit accessories of suitable dia medium grade including running up of one runs of10 Sq mm FRLS copper conductor multistranded PVC insulated cable as earth continuity conductor along the wiring and connected to the common earth dolly completeincludingremovingtheexistingunserviceablesubmain wiringandmakinggood thedisturbed surfaceto match with the existing all as specified.Note:-two runs of cable, one run of earth contuinity conductor and one run of conduit shall bemeasured and paid as one unit length. 152 Earthing complete with galvanised steel earth plate electrode 60cm x60cm x6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth earth lead 4 mm dia, by means of nuts, bolts,check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe light grade 15mm bore from earth elelctrode to test pointincl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25x6mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI pipelight grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point made out of Bronze/Gun metalwith fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, all as per electrical plate No 5 of SSR Part-I and connection to earth test point all as specified incl testing on completion. Note :- Item of Earthing includes cost of 7.5m long galvanised iron earth lead 4 mm size and protection pipe of 15 mm bore GI light grade. 153 Disconnecting and removingceiling/exhaust fan of any capactiy any height from electrical connection bringing down, dismantling, cleaning internally and externally thoroughly examine replacement of split pins, cotter pins and check nuts etc overhauling, lubricating with approved lubricants, reassembling, includingreplacement of wornout/defective parts, refixing in original position includingminor repairs for the smooth functioning and provision of new flexible wire of size 23/0.0076 multistranded copper conductor cable from ceiling rose to fan NOTE :- (1)Necessary repairs/ replacement of unserviceable parts shall be measured and paid seperately.(2)Labour element for replacing of u/s parts deemed to be included in rate quoted. 154 Material and labour for rewinding of the ceiling/exhaust fan complete with equivalent new super enamelled copper wire of existing gauge and weight as per manufacturers design and instructions including varnishing of ceiling fan of any make and any sweep complete all as specified and directed including taking out burnt copper wire. Note: old winding material is property of the contractor 155 Supply & Fix in repair of Ball bearing/Brass bushof Ceiling Fan/Exhaust Fan 156 Supply & Fix in repair of Capacitor Ceiling Fan/Exhaust Fan 157 Painting of ceiling fans 48”/56” size complete at site, with super synthetic enamel paint by spraying incl filling cavities with filler, one coat after cleaning all dust etc complete,all as specified and as directed by Engr-in-Charge. 158 Taking down the geysers of capacity 25 Ltrs from its mounting position by removing all water and electric connections and de-assembling the geyser and carrying out the following works, (a)Descaling, cleaning the inner tank thoroughly and there should not be any bad taste of water.(b)Examining the water tightness of storage tank after cleaning.(c)Examining the physical condition of thermostat, base assembly fusible plug and outer tank for its serviceability.(d)Inspection of pilot lamps.(e)Reassembling the geyser parts and testing including checking all electrical system (ensuring there is no current leakage) and also conducting hydraulic testing.(f)Re-fixing the Geyser and making electric connections,inlet and outlet water connections and testing and checking of all water inlet, outlet valves connected with geysers.Note : Defective /worn outpartsif required shall be measured and paid separetely under relevant items in this schedule. 159 Supply and fixrubber PVC connection of 2 feet complete, all as specified and as directed by Engr-in-charge. 160 Supply & fix rubber PVC connection of 3 feet complete, all as specified and as directed by Engr-in-charge 161 Supply & fix MS base plate cup any type with screws of suitable size as per requirement complete, all as specified and as directed by Engr-in-charge. 162 Supply & fix heating element of the 2 KW rating as required at site including rubber washers of any make and type complete as per sample, all as specified and as directed by Engr-in-charge 163 Supply & fix Steel inner tank of 25 litre capacity geyser tank by made out of copper sheets appropriate thickness complete, all as specified and as directed by Engr-in-charge. 164 Supply & fix thermostat for the geysers of the 25 Liters capacities complete, all as specified and as directed by Engr-in-charge 165 Supply & Replace Air Release Valve of Existing Size all as specified and directed by Engg in Charge 166 Supply and Replace Indication lamp of Existing Size/Model (Set of Two) Red & Green 167 S&F in replacement of 1100 Volt grade cable flexible 3 core PVC insulated PVC sheathed with stranded copper conductor of size 2.5 sqmm all as specified and as directed by Engr-in-charge 168 S&F in replacement of metallic louvers mounted suitable for exhaust fan of 300 to 450 mm on wall all as specified and as directed by Engr-in-charge 169 Supply and Fix Rigid non-metallic PVC conduit 20 mm inclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.complete all as specified and directed 170 Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed by Engineer-in-Charge.