| 1 | WIRING IN STEEL & PVC CONDUIT |
| 2 | Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopper conductor,single core cable in surface/ recessed steel conduit as required. |
| 3 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable insurface /recessedmediumclassPVCconduit,withmodular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 4 | Group C |
| 5 | Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopper conductor,single corecableinsurface/recessedmediumclassPVCconduitas required. |
| 6 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 7 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 8 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 9 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 10 | SupplyinganddrawingfollowingsizesofFRLSPVCinsulated copperconductor, singlecorecableintheexistingsurface/ recessed steel/ PVC conduit as required. |
| 11 | 3 x 2.5 sq. mm |
| 12 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 13 | 20 mm |
| 14 | Supplying and fixing following modular switch/ socket on the existing modularplate&switchboxincludingconnectionsbutexcluding modular plate etc. as required. |
| 15 | 3 pin 5/6 A socket outlet |
| 16 | Supplyingand fixingtwo module steppedtypeelectronicfan regulatorontheexistingmodularplateswitch boxincluding connections but excluding modular plate etc. as required. |
| 17 | Supplyingandfixingfollowingsize/modules,GIboxalongwith modular base & cover plate for modular switches in recess etc. as required. |
| 18 | 1 or 2 Module (75mmX75mm) |
| 19 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit,and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 20 | Group A |
| 21 | Supply and fixing following size DLP plastic trunking including all necessory accessories. |
| 22 | wiring accessories suitable for DLP trunking |
| 23 | Supply and fixing following size DLP plastic trunking including all necessory accessories - Supplying and fixing suitable size modular plate and cover in front on existing DLP trunking, including providing and fixing 6 pin 5/6 &15/16 A modular socket outlet (3 modular) and 15/16 A modular switch, connections etc. as required. |
| 24 | Supply and fixing following size DLP plastic trunking including all necessory accessories - Supplying and fixing suitable size modular plate and cover in front on existing DLP trunking, including providing and fixing 3 pin 5/6 A modular socket outlet (3 modular) and 5/6 A modular switch, connections etc. as required. |
| 25 | DLP Pastic Trunking150x50mm including all accessories (end cap, junctions, joints, wall crossing, VDI accessories etc. as per site condition)with flexible cover and clipon partition. |
| 26 | MCCB, MCB & DB\"S |
| 27 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar,interconnections,powderpaintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 28 | 12 way , Double door |
| 29 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles intheexistingMOBDBcompletewithconnections,testingand commissioning etc. as required. |
| 30 | Single pole |
| 31 | Double pole |
| 32 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V,residual current circuit breaker (RCCB),having a sensitivity current 30mA inthe existingMCBDBcomplete with connections, testing and commissioning etc. as required. |
| 33 | 25A |
| 34 | Supplying and fixing followingrating, four pole, (threephase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existingMCBDB complete with connections, testing and commissioning etc. as required. |
| 35 | 63A |
| 36 | Supplying and fixing 40 A to 63 A rating, 240 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles intheexistingMCBDBcompletewithconnections,testingand commissioning etc. as required. |
| 37 | 40-63 A Double pole |
| 38 | 40-63 A Single pole |
| 39 | CABLE TRAYS |
| 40 | Supplying and installing following size of perforated Hot Dipped GalvanisedIron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joinedwithconnectors,suspendedfromtheceilingwithG.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 41 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 42 | MISC. CIVIL ITEMS |
| 43 | Supplying and fixing Cable protector FollowingHeavy duty Flip open cover, Material Durable Industrial Grade Rubber Base & polyurethane Lid, Wear proof and non-deforming for long-lasting use |
| 44 | Two channel Cable protector |
| 45 | ELECTRICAL FIXTURES |
| 46 | Supply and fixing of following Wall mount Fan with necessory arrangement |
| 47 | Supply and fixing of 450 mm sweep wall mount fan with Aluminium blades, 1350RPM, minimum 100 CCM air delivery Wall mount Fan with necessory arrangement (Crompton Sstorm2 Wall mount or equvalent ) |
| 48 | LABOUR |
| 49 | Removing of following items and handing over to EMU safely. |
| 50 | Removing tube light and fixture with/with outrad/clamp from cealing/wall handing over to EMU store safely as required. |
| 51 | Removing cealing/wall fan withrad, regulator from switch board, handing over to EMU store safely including stacking of fan leafs as required. |
| 52 | Removing of point wiring including cealing rose, conduit, wires, switches(modular/piano type) switch board, clamps etc. as required and handing over to the store/yard. |
| 53 | Removing of submain wiring including conduit, wires, clamps etc. as required and handing over to the store/yard. |
| 54 | Removing of switch board of any size including wires, switches(modular/piano type) switch board, clamps etc. as required and handing over to the store/yard. |
| 55 | Removing of Vertical/Horizondal type SPN/TPN MCCB/MCB DB including connections MCBs MCCB\"s, Insulating open terminals etc. as required and handing over to the store/yard. |
| 56 | Removing of Centralized AC duct of maximum 0.5 m.sq. size (cross section) including dismantling, supports, clamps, any other related items etc. as required making good damages and handing over to the store/yard. |
| 57 | LEDDownlighter(SMD Type)(Systemlumenefficacy≥ 105 < 120 lm/Watt ) Supplying, installation, Testing & Commissioning ofLED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD typeof following body materialwith PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 degto40degcentigrade,internalsurgeprotectionof2.5KV withShort&Opencircuit protection ,THD < 10% , P. F.≥0.95,IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%),life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with70% of initial Lumenmaintained tilllife ends , CCT 3000°K /4000°K/ 5700°K / 6000°K / 6500°K (AsperANSIBin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumptionshouldnotmorethan the specified rating and Fixture shall be confirming to relevant BIS standards andtrade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Completeinallrespecti/cconnectionswith1.5sqmmFRLS, PVCinsulatedcopper conductor single core cable and earthing etc. as requiredwith Minimum 5 year OEM warranty.System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test reportfromNABLlab forall testingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkofaluminumhousing such that LED junction temperature shall not rise above 90°C) Powdercoateddiecast/Extruded aluminum Body including trim |
| 58 | 18 watt |