Tender For Construction Of Academic Block Building In University College Of Engineering, Bit Campus, Trichy District.; 1 Earth work excavation for foundation by Mechanical means for Isolated & Combined Footing etc in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers.- 2.40m-3.30M Footing Depth.Data worked out for 48 m3 per day/8 hrs. 2 Earth work Open excavation by Mechanical Means for Open Earthwork in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers.A). Upto 2.40m Depth.Data worked out for 64 m3 per day/8 hrs 3 Refilling with excavated earth other than sand with an initial head load of 100 mts and depositing the earth as shown by the departmental officers in layers of not more than 15cm thick well rammed with surface vibrator, watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers. 4 Supply and filling in foundation and basement with Gravel in layers of not more than 15cm.thick well rammed watered and compacted with surface vibrator, watered and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 5 Supplying and Filling in foundation and basement and trenches with M-Sand in layers of not more than 15cm thick well rammed watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers. 6 Supplying and filling of 40mm HBGS metal in dispersion trench around the stoneware pipe or in the leach pit or rain water harvesting pit or soak pit to the required thickness complete complying with standard specification and as directed by the departmental officers. (The rate including cost of metal filling etc. complete complying with standard specification.. 7 Supplying and filling of 20mm HBGS metal in dispersion trench around the stoneware pipe or in the leach pit or rain water harvesting pit or soak pit to the required thickness complete complying with standard specification and as directed by the departmental officers. (The rate including cost of metal filling etc. complete complying with standard specification. 8 Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers -Mixing by mechanical means 9 Providing Anti – termite treatment to soil adjacent and under building foundation, plinth periphery of the building by application of chemicals of IS 6313 part I to IV in stage to suit the progress of work consist as per the detailed specification as below (Measurements taken for the plinth area for the purpose of payment) including braking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport & storing etc., complete and as directed by the departmental officers.(The chemical should be got approved by Executive Engineer before use on work).Stage -1 : Spraying Anti –termite chemical solution for the foundation before laying concrete, in bottom and sides of foundation.Stage-2 : Spraying Anti –termite chemical solution to the grade beam level, spraying has to done for to grade beam brick masonry contact with the back fill earth.Stage-3 : Spraying Anti –termite chemical solution on the sand for the flooring before laying the flooring concrete. This treatment has to be carried out and sand filling by making holes with crow bar to a depth of 60cms and at 60cms intervals on both direction and at junction of wall and flooring throughout.Stage -4 : Spraying Anti –termite chemical solution alround building outside by making holes with crow bar before laying plinth protection and the holes to be close after the treatment. etc., complete complying with standard specification and as directed by the departmental officer. 10 Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost ofreinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). 11 For Foundation & Basement 12 For Super structure in Ground Floor 13 For Super structure in First Floor 14 For Super structure in Second Floor 15 Providing and laying in position, Standardised Concrete Mix M-25 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS:456- 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kglm3 and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). 16 For Foundation & Basement 17 For Super structure in Ground Floor 18 For Super structure in First Floor 19 Providing and laying in position, Standardised Concrete Mix M-35 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS:456- 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 425 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability withoutimpairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). 20 For Super structure in Ground Floor 21 Post Tensioning Work: Design and execution of post tensioning work, including decoiling, the strands, cutting to the required lengths, supplying, laying of HT strands sheathing (GI corrugated ducts 0.3mm thick) jointing with couplers and inserting the strands, profiling, fixing liveend anchorages, including supply of stressing anchorages, suitable for 5-5 & 5-4 tendons, grout vents,making dead end anchorages, including flowering the strands, fixing tendon support bars, supervising the fixing of antibursting reinforcement, stressing the cables, end trimming, grouting the cables, with cement slurry, mixed with admixtures with required tools, plants, and machineries, and consumables etc. (Shuttering,concreting & reinforcement steel shall be paid under respective items) at all heights including all leads, lifts, coordination, with the post- tensioning agency, preparation of drawings, obtaining approval from the Employer / Architect etc. Rate to include providing water, power, cement and admixture for grouting, packing of sheathing and anchorages blockings, filling of recess pockets after stressing using grouts (cement slurry mixed with approved admixtures) including providing access to post tensioning at all heights including all leads, lifts etc., all complete and as approved and as directed by the Employer Architect but excluding shuttering, concreting & reinforcement steel which shall be payable under respective items separately. 22 Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two crushed st one sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed by the departmental officers. 23 50mm thick 24 75mm thick 25 Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) 26 For Foundation & Basement 27 For Super structure in Ground Floor 28 For Super structure in First Floor 29 For Super structure in Second Floor 30 Finishing the top of roof with Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.-Mixing by mechanical means 31 For Foundation & Basement 32 For Super structure in Ground Floor 33 Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner , vertical stiffener , side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). 34 Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). 35 Supplying and erecting steel centering including necessary supports For plane surfaces such as rectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick).etc..complete in all floors complying with standard specifcation. Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). 36 Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc. using mild steel sheets of size 1200cm x 60cm and 10 BG stiffened with welded mild steel angles of size 40mm x 40mm x 5 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner, Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals. MS Channel Section (ISMC 100) shall be provided as a vertical support @1.20m C/C and with Lateral support of Steel Adjustable Telescopic Props of Size 2m x2m (expandable upto 3.60m) & steel pipes of 20mm dia @ required level/spacing etc. complete complying with standard specifcation and as directed by the departmental officers. (Payment for centering shall be given after the concrete is laid) 37 Supplying and erecting centering for plane surfaces such as RCC Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks etc.. with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over Steel adjustable Span of Size 2m x 2m(expandable upto 3.60m) and Silver Oak Joists of Size 10 x 5 cm spaced at 50cm to 60cm c/c and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) Spaced at not more than 50 to 60cm c/c , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). 38 Brick work in 1:6 Cement Mortar using best quality Fly ash Brick of size 230x110x70mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge. 39 For Foundation & Basement 40 For Super structure in Ground Floor 41 For Super structure in First Floor 42 For Super structure in Second Floor 43 Brick work in 1:5 Cement Mortar using best quality Fly ash Brick of size 230x110x70mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge. 44 For Foundation & Basement 45 Brick work in 1:3 Cement Mortar using best quality Fly ash Brick of size 230x110x70mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge. 46 For Foundation & Basement 47 Damp proof course as per IS 3067:1988 with Cement Mortar 1:4 (One Cement and Four crushed stone sand) 12mm thick mixed with best approved quality Integral liquid water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used , finishing and curing etc. complete complying with standard specification - Machine Mixing 48 Brick partition walls of 11.50cm thickness using best quality Fly ash Brick of size 230x110x70mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 in Cement Mortar 1:3 (One Cement and Three CS Sand) using hoop iron reinforcement if found necessary including Cost of Mortar Plasticizer, curing etc. complete complying with standard specification and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) 49 For Super structure in Ground Floor 50 For Super structure in First Floor 51 Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers 52 Stucco plastering 12mm thick using blue granite chips of size 10mm and below over a base plastering with cement mortar 1:5, 12mm thick, etc., complete complying with standard specifications 53 Plastering the surface of walls with Cement Mortar 1:5 (One cement and Five plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used , curing etc., complete complying with standard specification andas directed by the departmental officers. 54 Plastering with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 12mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including mortar plasticizer at 200ml per 50Kg of cement used, finsihing, curing, etc., complete in all floors complying with standard specification and as directedby the departmental officers. 55 Painting two coats of newly plastered wall surface with ready mixed plastic Interior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed by the departmental officers. 56 Painting the wall two coats with approved weather proof Exterior Emulsion paint over one primer coat on cement plastered wall surface ect., complete complying with standard specification and as directed by the departmental officers. 57 Paving the Top of roof with Solar refelective ceramic tiles of approved quality and colour laid in Cement mortar bed in 1:3 (One cement and three crushed stone sand) 12mm thick and pointed with water resistant tile epoxy grout for joint, curing etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by the Executive Engineer beforeuse on works) 58 Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessory PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of “U” clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification and as directed by the departmental officers 59 160mm dia PVC Pipe - For One Floor 60 160mm dia PVC Pipe for Two Floors 61 160mm dia PVC Pipe for Three Floors 62 110mm dia PVC Pipe for One Floor 63 Paving the floor with best quality Double charged Vitrified tiles 600 x 600 x 8mm size of approved colour and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) 64 Paving pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in accordance with IS 1443 in Cement Mortar 1:3 (One Cement and Three crushed stone sand), with required Cement Slurry and Mortar Plasticizer, 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) 65 Paving the floor with Tactile paver type of new tack BT yellow colour ceramic tiles of approved quality and colour of size 305 x 305 x 15mm in all floors over a base layer of cement mortar 1:3 (one cement and three M sand) 20mm thick and pointing with white cement using 0.30kg/m2 including adding suitable colour pigments to suit the colour of tiles finishing perfectly and curing etc., including cost of tiles, all materials and incidential charges, transportation charges and labour charges for laying tiles etc., complete complying with standard specification and as directed by the departmental officers . (The tiles should be got approved by the departmental officers before use on works). 66 Paving the floor with best approved quality fine polished Granite Synthetic Slabs of 1200 x 600 of 16/ 18 mm thick size and synthetic grey, Paradise of similar Variety with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., complete complying with standard speicification and as directed by the departmental officers.(The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work) 67 Labour charges for finishing the top of working tables and staircase step portion with nosing arrangements in Granite slab tiles including cutting the edges and polishing including cost of polishing materials complete complying with standard specification and as directed by the departmental officers. 68 Flooring with ceramic tiles of Colour and Design Ceramic Tiles of size 305x305x6mm and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m.etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) 69 Dadooing walls with following best approved quality, printed design colour glazed tiles of size 150mm x 150mm x 6mm glazed tiles conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) 70 Supplying and fixing of PVC corner size beeding of best approved quality of 25 x 75 mm size and thickness of required height of walls using cement mortar 1:2 (One cement and two sand) and finishing the surface smooth with ceramic tiles etc., complete complying with standard specification and as directed by the departmetal officers. 71 Providing granolithic floor finish of the 20mm thickness with plain cement concrete 1:2:4 (One Cement, Two Crushed Stone Sand and Four aggregate) using 6 to12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trowel, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers) 72 Supplying ,fabricating and fixing in position of steel frame without bottom frame, of size 100X60mm rectangular section with necessary rebate 30mmX15mm, to host the shutter,using 1.25mm thick (18 guage) CRCA cold rolled frame steel plate confirming to ISI specified ensured of right butt joint riveted hold assembly with nylon insert,not be welded with special purpose hard ware.Proclaimed including phopating as per ISI with rust preventive primer ready to assemble condition for easy installation at site including dismantling,making necessary chipping and holes in RCC columns, walls with power drills to the extent required ,including providing concrete 1:2:4 inside the box curing etc... complete complying with standard specification and as directed by the departmental officers. 73 Supplying and fixing in postion of 35mm thick solid core flush door shutters with following specification. with TW ply on both sides and with TW lipping of size 35x12mm on all edges with necessary adhesives and C.P. Screws Alu. Butt Hinges (6 nos. 250 x 16 mm Size) Alu. Aldrop1 No. 250 x 16 mm Size, Alu. Tower Bolt 2 No. 250 x12 mm size, alu. Tower Bolt 2 No. 200 x 12 mm size, D type alu. Handle 200mm length 2 No., alu. door stopper with rubber bush 2 No. shall be provided, as directed by the departmental officers etc., complete. 74 Single Leaves 75 Double Leaves 76 Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work 77 Manufacturing, supplying and fixing of 1/3 panelled and 2/3 grilled steel doors with the following specification M.S angles of a size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames stiffeners with 32x6mm M.S. flat is provided at required intervals in the shutter frames 18 gauge C.R. sheet is laid as panel in the shutter and welded intact for 1/3 bottom portion of the shutter. M.S. flat 18x5mm is welded over the 32x6mm M.S. flat sandwitching the CR sheet in between. Additional stiffener with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter. The balance 2/3 portion at top is provided with grill at an average weight of 20kg/sq.m and 3 Nos Steel Parliament Hinges of Size 125mm x 150mm incase single leaves shutter to be provided, 6 Nos Steel Parliament Hinges of Size 125mm x 150mm for double leaves shutter to be provided, 6nos of holdfasts 200mm in length made of angle section spliced at the ends are welded to the outer frame of the door. Tower bolts 3 nos, one at the top, one at lock rail(Inner) and the other at the bottom are provided. one aldrop is provided at on appropriate place in the door. 2Nos of handle are to be provided. A Tie bar is provided at the bottom of the outer frame to prevent twisting of frame during transportation or fixing. All members are given one coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, taxes, transportation to site of work, loading, unloading and all other incidental charges etc., complete complying with standard specification and as directed by the departmental officers. - Single leaf of size 1.00m x 2.10m. 78 FRP Door Sutter with FRP Door Frames made out of FRP Sheets of 3mm thick of over all size 65mm x 50mm with rebate suitably reinforced using MS Angle / Flats, cost of holdfasts and Solid Core FRP Shutter Panel of 5mm thick and hollow core frames of 3m wall thickness for styles and rails etc., of sizes specified by Engineers 79 Supplying and fixing of PVC Sliding Door with Roller using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC Sheets. Shutter using 5mm thick solid PVC Sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter 80 UPVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work. 81 Supplying and fixing MS grills to doors, windows and ventilators etc. using necessary MS flats (or) square rods for inner members and outer members which should be fixed to window frames as directed and design given by the departmental officers inclusive of cost of providing one coat of best quality red oxide primer etc., complete complying with standard specification and as directed by the departmental officers . 82 Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with One coats of best approved first quality and colour of synthetic enamel paint over the priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) 83 Painting the new wood work two coats with best approved first quality and colour of synthetic enamel paint over a priming coat of approved quality in all floors including cost of paint, labour and other materials like brushes, putty and scaffolding charges etc., complete complying with standard specification and as directed by the departmental officers. (The make quality and colour of paint should be got approved by the departmental officer before use on work). 84 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete 85 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete 86 Providing expansion joint of 12.5mm wide in between RCC twin columns from top of pedastal to full height including filling the inner space with suitable nonabsorbent, flexible and well compressible filler materials of approved quality and brand; finishing the sides of RCC columns with polysulphide sealents for a depth of 7.5mm on either side covering the inner space filled with filler materials as above etc., complete complying with standard specifications and as directed by the departmental officers. 87 Providing expansion joint in RCC floor slab for 12.5mm width using polysulphide as sealent on the top and bottom for a depth of 7.5mm each and packing the inner space using compressible non-absorbent filler materials including cost of labour for cutting and fixing filler materials and laying polysulphide sealent with necessary spatula etc., complete complying with standard specifications and as directed by the departmental officers 88 Providing expansion joint 12.5mm width in RCC roof slabs between RCC twin beams using PVC water bar of 150mm wide centre bulb of 4mm to 6mm thickness of approved quality and brand and including filling the inner space with suitable non-absorbent flexible and well compressible filler materials of approved quality and covering the top surface with GI sheet 30cm wide and 1.6mm thick using phill plugs, GI screws, limpet cup washers, bitumen washers, etc., complete complying with standard specifications and as directed by the departmental officers. 89 Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete. 90 Brick Jelly Lime Concrete 1:2:5 using 40mm brick jelly in Lime Mortar 1:2 using limestone and sand - 10 Cu.m for sunken portion etc. complete complying with standard specifications and as directed by the departmental officers. 91 Supplying and fixing in position CI manhole covers with CI frames (Heavy duty) of size 60cm x 60cm of best approved quality as per standard specification etc., complete compying with standard specifications 92 Supplying and fixing PVC ventilating shaft of 110mm dia (having working pressure 4 kg. / sq.cm) with 3 metre height including cost of PVC cylindrical cowl of best approved quality etc., complete complying with standard specifications and as directed by the departmental officers 93 Supplying and fixing of RCC hume pipe of flush joint to a size 300mm RCC wall with 25mm thick to a length of 30cm in RCC M 35 with nominal special reinforcement as directed by the departmental officers etc., complete complying with standard specification. 94 Supplying and installation of Ceramic Steel chalk writing board with the following specification. The 2mm GI Sheet is placed with wall side over the GI sheet necessary adhesive is spreaded and fixed the 9mm MDF board on the GI sheet 0.40mm thick ceramic steel chalk board is provided over the MDF board and the whole arrangements are fixed to the frame using heavy anodized Aluminium section and Chromium plated provided in the corners. The whole arrangement are fixed to the wall using wooden plugs and screws etc., The rate includes all above materials, labour charges and taxes etc., complete complying with standard specification and as directed by the departmental officers. 95 Supplying and fixing of good quality and best make of Chalk Piece and Duster Holder of size 300 x 200mm made up of stainless steel in the places shown by the departmental officers including transporting to the work site, fixing in position etc., complete complying with standard specification. 96 Supplying, fabricating, erecting and fixing Hilux (or) equivalent board false ceiling upto a ceiling height of 4.5m from floor level.etc., complete complying with standard specification and as directed by the Departmental officers 97 Supplying and fixing Gyp-board designed Cornices of 100x60mm width in the edges of the false ceiling wherever necessary as per the direction of the filed officers. The rate includes the cost of materials, transportation charges and fixing charges and other incidental charges etc., the pattern of the cornice has to be approved by the Executive Engineer before used on work etc., complete complying with standard specification and as directed by the departmental officers. 98 Supplying and fixing ornamental Brass-in-lay Burma Teak Wood Entrance Door with a size of 2.10 m x 2.55m with six leaves as per the drawing and design as approved by the departmental officers.The clear opening of each door shall be of 2.00m. The outer frames are of finished size 175mm x 125mm.The Each door shall have two leaves of 1/3 panelled and 2/3 glazed. The Outer frame of the shutter of finished size of 150mm x 50mm.All the Panels shall be of finished 50mm thick. The main outer frame, shutter frame and panels shall be engraved with computer design ornamental carving works of approved pattern with skilled carpenter as directed by departmental officers. All the glazing works shall be done with design painting works.Necessary grill protection arrangements shall be made for the glass portion. The door frame and shutters shall given two coats of best and approved quality of high Glossy Polyurethane finish.The rate includes cost of best and approved quality of Burma Teak wood,design painted glass, Brass hinges,Tower bolts, Aldrop, locking arrangments,ornamental handles,brass screws and labour charges, transportion charges, all taxes, etc., complete. 99 Drilling 150mm dia vertical bore well to the required depth as directed by the departmental officers including labour charges inserting pipes assembly in the drilled pit including welding the joints wherever necessary and grouting the casing pipe if necessary in hard rock etc. complete and including transportation charges for the rigs and supporting vehicles from one place to another etc. complete as directed by the Executive Engineer. 100 Upto 150m BGL 101 Upto 150m to 180m BGL 102 Upto 180m to 210m BGL 103 Supplying 160mm dia Special Blue Slotted Pipes for Bore Wells of pressure 6kg/m2 in the drilled hole of the following dia in 3m length with screwed and socket ends and centering guide for every 15 m length of pipes as per I S I 12818/1992 inclding welding the joints supplying and poeting the annular space with pebbles of size and quality etc complete as directed by the departmental officer 104 Supply of 160 mm dia PVC End cap of best approved quality having pressure of 6 kg/sq.cm. etc. complete as directed by the departmental officers. The pipe should be got approved by the Executive Engineer before use on works. 105 Supplying and delivery of best and approved quality of 40mm dia HDPE pipe of 10kg/m2 size including laying in the basement and tying with copper wire etc., complete complying with standard specification for delivery line from the bore from submersible pump in borewell and as directed by the departmental officer. 106 Supplying and fixing of MS borewell clamp suitable for 40mm dia pipe and 4 Nos. of bolts and nuts of best approved quality etc. complete and complying with standard specification and as directed by the departmental officers . 107 Supplying, fixing and Erecting in position of single phase 5.00 H.P Submersible Pumpset suitable for 150mm dia Borewell with ISI IS 8034 with 3 phase Panel Board - Star Delta with two level guard and Auto start including Transport charges etc., complete complying with standard specification. 108 Supplying and tying of Nylon rope of 18mm dia thread make with best quality for holding submersible pump etc., complete as directed by the Executive Engineer. The Rope should be got approved by the Executive Engineer before use on works. 109 Supply of 2.50 Sq.mm PVC insulated and shethed 3core flat type finolex copper cable for motor pump electrfication confirming tro IS 694/1996 including conveyance to work site etc.. 110 Supplying, laying and jointing UPVC pipes of Class 6 (having working pressure of 12.50 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety conforming to BIS of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works - External water supply Below ground level. 111 50mm dia UPVC pipe 112 Supplying, laying and jointing UPVC pipes of Class 6 (having working pressure of 12.50 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety conforming to BIS of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works - External water supply Above ground level. 113 40mm dia UPVC pipe 114 32mm dia UPVC pipe 115 Supplying, laying and jointing UPVC pipes of Class 6 (having working pressure of 12.50 kg/ sq.cm) conforming to IS 4985- 2000 of approved quality and best variety of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works - Internal water supply above ground level. 116 25mm dia UPVC pipe 117 20mm dia UPVC pipe 118 Supplying and fixing the following UPVC specials of heavy type and approved quality and good variety excluding the fixing charges but including necessary cutting and threading on UPVC pipes for jointing UPVC Specials and providing two coats of painting with good variety of paint over a coat of priming coat in the case of pipes line above ground level and one coat of tarring in case of the pipelines above ground level and one coat of tarring in case of the pipelines below ground level etc,complete 119 50mm dia UPVC Union 120 40mm dia UPVC Union 121 32mm dia UPVC Union 122 25mm dia UPVC Union 123 50mm dia UPVC Elbow 124 40mm dia UPVC Elbow 125 32mm dia UPVC Elbow 126 25mm dia UPVC Elbow 127 40mm dia UPVC Hex Nipple 128 32mm dia UPVC Hex Nipple 129 25mm dia UPVC Hex Nipple 130 25x20mm UPVC Reducer Elbow 131 20x15mm UPVC Reducer Elbow 132 40mm dia UPVC Tee 133 32mm dia UPVC Tee 134 25mm dia UPVC Tee 135 25x20mm UPVC Reducer Tee 136 20x15mm UPVC Reducer Tee 137 Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the departmental officer before use on work. 138 32 mm dia Gate Valve 139 25 mm dia Gate Valve 140 Supplying and fixing in position 15mm dia brass CP screw down tap tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works) 141 Supplying and Fixing of PVC ready made water tank of approved quality with standard specification and best brand including testing for leakages after making installations and connections. The cost inclusive of lid and lock with bolt and nuts for PVC tank, transportation, loading, unloading, lifting, installation and necessary connections etc., complete complying with standard specifications and as directed by the departmental officers.(The PVC Water Tank should be got approved by the Executive Engineer before use on works). 142 Supplying and fixing in position Indian water closet oriya type of size 580x440mm white glazed earthernware of approved quality with P trap or S trap conforming to IS 2556-Part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to PVC. pipes by dismantling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specification and as directed by the departmental officers.(The Oriya type Water Closet and all accessories should be got approved by the departmental officers before use on work) 143 Supplying and fixing in position White Glazed European water closet of best quality and approved make with 100mm P or S trap with double flapped rigid PVC.seat cover with chromium plate brass hinges, including supplying and fixing PVC. Low level flushing tank 10 litre capacity of approved quality on wall with teak wood plugs, brass screws and 2 numbers 15mm dia gun metal wheel valve, 15mm dia nylon connection and giving necessary water supply connection as directed by the departmental officers. The rate includes cost of 100mm dia PVC.Pipe 60cm long including cost of 3 Kg.of white cement 6Kg.of cement, spunyarn, shellac, thread ball, teak wood plugs, brass screws 75mmx10mm etc., complete complying with standard specification and as directed by the departmental officers. (The European Water Closet and flushing tank should be got approved by the Departmental Officers before use on work.) 144 Flooring with Snow White Marble Slab (Adanga) 18mm to 20mm thick and above free from all defects in all floors over a base layer of CM 1:3, 20mm thick including Mortar Plasticizer. The marble slab shall be laid over the cement mortar by applying cement slurry in between base mortar and marble slab and pointed with white cement neatly including polishing with polishing stone and oxalic acid etc. so as to perfectly smooth and glossy and including hire charges for polishing machine and power consumption charges etc. complete complying with standard specification and as directed by the departmental officers. (The marble slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work). 145 Supplying and fixing Stainless steel health faucet of best quality with control valve etc., complete complying with standard specification and as directed by the departmental officers (The materials should be got approved by the Executive Engineer before use on works). 146 Supply and fixing in position of best Indian make white glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers. (The urinal should be got approved by the Executive Engineer before use on works.) 147 Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia “B” class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). 148 Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 5.5mm thick mirror of following size , Shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc.,complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks) Size :600 x 450 mm / 500 x 400mm / 1000 x 780 mm. 149 Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works). 150 Supplying and fixing position CI Nahani Trap of size 100 x 75mm sizes with pvc gratings with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of crushed stone sandand five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving conne tion to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works) 151 Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the departmental officer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level 152 75 mm dia PVC soil waste pipe 153 110 mm dia PVC soil waste pipe 154 160 mm dia PVC soil waste pipe 155 Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and redoing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works). 156 110mm dia PVC door Tee 157 110mm dia PVC Door Y 158 75mm dia PVC door Elbow 159 75mm dia PVC plain Bend 160 PVC Cowl 110mm dia 161 PVC Cowl 75 mm dia 162 Supplying and fixing of Incinerator for Ladies Toilet etc., complete complying with standard specification and as directed by the departmental officers. 163 Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. 164 Supply and fixing of Water CO2 Stored Pressure Type 9 litres capacity Fire Extinguisher as per new IS 15683 complete with control valve, gun metal cap, pressure gauge, operation sticker, discharge hose, wall mounting bracket, safety clip, etc., as directed by the Departmental Officers. 165 Supplying and fixing of Hylem sheet 3mm thick for expansion joint etc., complete complying with standard specification and as directed by the Departmental officers 166 Construction of INSPECTION CHAMBER of clear size of 600x600mm including earth work excavation, CC 1:5:10 of 10 cm thick and brick work in Cement Mortar 1:5 [One cement and Five M sand] using best quality of second class Table Mould Bricks of size 9 x 43/8 x 23/4 with Plastering with Cement Mortar 1:3 [One Cement and Three Plastering Sand] 12 mm thick to inner and outer sides and wearing coat 1:3:6 [One Cement, Three crushed stone sand and Six Aggregate] 15 cm thick and covered with precast slab 5 cm thick etc., complete complying as directed by the departmental officers as per standard specification. 167 Providing granolithic floor finish of the following thickness with Combination Mortor (Cement:Lime:Sand) 1:1:7 including laying, finishing and the top rubbed smooth with power trowel, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers) 168 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) ( 4 points / Coil) Higher End etc., complete complying with standard specification and as directed by the Departmental officers 169 Wiring with 2 x1.5 sq.mm PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sqmm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End ) etc., complete complying with standard specification and as directed by the Departmental officers 170 Wiring with 2 x1.5 sq.mm PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sqmm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End etc., complete complying with standard specification and as directed by the Departmental officers 171 Supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (Higher End) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting. etc., complete complying with standard specification and as directed by the Departmental officers 172 Supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (Higher End) complete with conduit pipe suspension from the ceiling with PVC unsheathed FRLS copper leads from terminals to the fitting with tube etc., complete complying with standard specification and as directed by the Departmental officers 173 Supply and fixing of 2 x 22W 4 Feet LED Fitting with 2Nos. of 2Mts. conduit pipe suspension from ceiling with 2Nos. of 18w crystal glass LED tube with PVC unsheathed Copper leads from terminals to the fitting. etc., complete complying with standard specification and as directed by the Departmental officers 174 Supply and fixing of WT bulk head fitting with guard (Higher end) suitable for 7W/9W LED Bulb etc., complete complying with standard specification and as directed by the Departmental officers 175 Supply and fixing of 18W LED square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting etc., complete complying with standard specification and as directed by the Departmental officers 176 Supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting etc., complete complying with standard specification and as directed by the Departmental officers 177 supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting .etc., complete complying with standard specification and as directed by the Departmental officers 178 Supply and fixing of 1200 mm (48) AC ceiling fan complete 2 module 100W fan step regulator with 500 mm down rod on the existing clamp. etc., complete complying with standard specification and as directed by the Departmental officers 179 Supply and fixing of 1200mm (48) ceiling fan complete 2 module 100W fan step regulator with 2mts. down rod on the existing fan clamp. etc., complete complying with standard specification and as directed by the Departmental officers 180 Supply and fixing of 400mm (16) sweep Wall mounting fan with necessary connection etc., complete complying with standard specification and as directed by the Departmental officers 181 Supply and fixing of 300 mm (12 inch) sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall.etc., complete complying with standard specification and as directed by the Departmental officers 182 Supply and fixing of louvers shuters arrangements for 300mm (12 inch) sweep (light duty) AC exhasut fan etc., complete complying with standard specification and as directed by the Departmental officers 183 Supply and fixing of 150W LED flood light fitting with Integrated driver (Higher end) complete suitable angle iron frame work on wall with unsheathed Cu Leads with MS clamps and aluminium painting complete etc., complete complying with standard specification and as directed by the Departmental officers 184 Supply and fixing of 1 no.6A two module 3 pin socket , 1 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End etc., complete complying with standard specification and as directed by the Departmental officers 185 Supply and Run of 2 of 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion etc., complete complying with standard specification and as directed by the Departmental officers(For 1No.6A plug) 186 Supply and fixing of 3nos.6A two module 3 pin socket , 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End etc., complete complying with standard specification and as directed by the Departmental officers) 187 Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End etc., complete complying with standard specification and as directed by the Departmental officers 188 Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion etc., complete complying with standard specification and as directed by the Departmental officers(For 3Nos.6A computer plug set & 16A Plug) 189 Supply and fixing of 25 Amps flush type wall Socket with 25A DP MCB in flush with wall with earth connection (For AC Plug) [Higher end make] etc., complete complying with standard specification and as directed by the Departmental officers 190 Supply and fixing of 6 A to 32 A DP MCB in 2 way sheet steel enclosure in flush with wall and making good of the concealed portion and earth connection. (Higher End) etc., complete complying with standard specification and as directed by the Departmental officers 191 Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB as incoming and 6 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only Higher End etc., complete complying with standard specification and as directed by the Departmental officers (Lighting only) 192 Supply and run of 2 of 4 sqmm PVC insulated SC unsheathed FRLS copper conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 sqmm PVC insulated sc unsheathed copper wire and making good of the concealed portion with suitable colour. etc., complete complying with standard specification and as directed by the Departmental officers(For 25A AC Plug, 32A DP MCB & 8W SPN) 193 Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 40A DP MCB Isolator as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End etc., complete complying with standard specification and as directed by the Departmental officers(For Computer plugs) 194 Supply and run of 2 of 6 sqmm PVC insulated SC unsheathed FRLS copper conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 6 sqmm PVC insulated sc unsheathed copper wire and making good of the concealed portion with suitable colour etc., complete complying with standard specification and as directed by the Departmental officers(12W SPN DB) 195 Supply and fixing of 32A FP MCB in sheet steel enclosure in flush with wall and making good of the concealed portion with earth connection. (Higher end) etc., complete complying with standard specification and as directed by the Departmental officers 196 Supply and run of 4 of 4 sqmm PVC insulated SC unsheathed FRLS copper conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 sqmm PVC insulated sc unsheathed copper wire and making good of the concealed portion with suitable colour. etc., complete complying with standard specification and as directed by the Departmental officers(For 32A FP MCB) 197 Supply and fixing of 7 segment 4 way TPN MCB sheet steel distribution board (Higher end) with metal /acrylic door cover flush type /surface type fitted with busbars and neutral links with single / Three phase MCB outgoings and seperate 4 way provision for accomodating one no 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one no. 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 4 ways in each segment) and seperate provision for MCB / Isolators (totally 12 nos) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq mm with the following in flush with wall with earth connection only.i) 63A 4P MCB - 1 no.ii) 63A 4P 30MA RCCB/ELCB - 1 no.iii) 63A DP MCB Isolator -3 nos.iv) 6A to 32A SP MCB - 12 nos. etc., complete complying with standard specification and as directed by the Departmental officers (Lighting Distribution DB) 198 Supply and fixing of 7 segment 6 way TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one No 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one No 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 6 ways in Each segment) and seperate provision for MCB / Isolators ( totally 18 Nos) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm. with the following in flush with wall with Earth connection only. i) 63A 4P MCB - 1 no.ii) 63A 4P 30MA RCCB/ELCB - 1 no.iii) 63A DP MCB Isolator -3 nos.iv) 6A to 32A SP MCB - 18 nos.etc., complete complying with standard specification and as directed by the Departmental officers (c.plugs,16A plugs- Distribution DB) 199 Supply and run of 4 of 10 sqmm PVC insulated SC unsheathed FRLS copper conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sqmm PVC insulated sc unsheathed copper wire and making good of the concealed portion with suitable colour. (For 63A FP MCB) etc., complete complying with standard specification and as directed by the Departmental officers(4w 7seg.63A TPDB) 200 Supply and fixing of vertical type 4 way triple pole MCB DB with metal door cover with IP 42 protection in sheet steel enclosure with 1No. 100A 4 pole MCB isolator as incoming 4Nos. 63A TP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCB DB and MCBs should be with the ISI mark (Higher End) etc., complete complying with standard specification and as directed by the Departmental officers 201 Supply and fixing of 8 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 100 A 4P MCB Isolator as incoming and 3 nos. 32A 3P MCB, 15 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End etc., complete complying with standard specification and as directed by the Departmental officers 202 Supply and run of 4 of 16 sqmm PVC insulated SC unsheathed FRLS copper conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 16 sqmm PVC insulated sc unsheathed copper wire and making good of the concealed portion with suitable colour.etc., complete complying with standard specification and as directed by the Departmental officers (4w (V) 100A TPDB & 8w (V) 100A TPDB) 203 Sub switch Panel: Supply and Erection of 250A capacity dust and vermin proof cubical panel board made up of 16 SWG CRCA sheet steel with supply and fixing of the following interior mounting fuse switch with HRC fuses arrangement in two Horizontal rows with one switch over the other, with a central bus bar chamber and two ends one on each side next to the fuse switch chamber and cable alloy conforming to IE rulesEB INCOMER: 250A FP switch disconnector fuse units interior only with HRC fuse Double Break Switch -1 NoOUTGOING:100A TPN switch disconnector fuse units interior only with HRC fuse Double Break Switch -4Nos63A TPN switch disconnector fuse units interior only with HRC fuse Double Break Switch -6 Nos(All the TPN Switch should be Siemens with Front Handle) Suitable The bus bar chamber will consist of suitable size of tinned copper flat for phase and neutral buses on epoxy moulded bus insulated at proper and sufficient spacing between the buses as per IE Rules. This bus bar chamber should be segregated from the adjacent chamber by providing hylem sheet of suitable thickness as partisans. 2 Nos 25x3mm tinned copper flats should be provided all round the panel for earth bus. 204 The fuse Switches should be connected with the phase and natural buses with suitable size of rigid copper flat/rod and each switch should be connected with the 2 Nos earth bus with 2 runs of No.8 SWG rigid Tinned copper rod with suitable lugs. Phase and neutral tinned buses should be tinned properly.The panel should have a separate metering chamber at the top side consisting of 0-600V Voltmeter with Selector Switch, 0-400A Ammeter with Selector Switch and C.T arrangement Pilot lamps, toggle switches, fuse unit(Siemens) indicator lamps should be provided with control switches and fuse unit The panel should be Powder Coat paint of approved colour, approved by the site officer and also the danger board .The capacity of the switches size of incoming and out going cable the place to which the supply is feed shall be mounted on switch chamber. The pannel board should be mounted on 75mm x37mm MS channel provided all round at bottom of the panel. The whole arrangement should be erected on a masonry pedestal to be constructed with suitable foundation bolts and nuts such that the lowest switch handle is at a height of 0.75 m from the ground level with necessary earth connection. (DATA-11) 205 Supply and Laying of 31/2 x 185 sq.mm. PVC armoured LTUG cable in120mm/103.50mm dia size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good etc., complete complying with standard specification and as directed by the Departmental officers(Existing MV panel to Academic block-New 250A Panel)(Existing MV panel to Seminor Hall -New 250A Panel) 206 Supply and clamping of 3½ X 185 sq.mm PVC LTUG armoured cable on post or on wall with MS clamps.etc., complete complying with standard specification and as directed by the Departmental officers 207 Supply and fixing of brass cable gland for 3-1/2 x 185 sq.mm. PVC LTUG aluminium armoured cable with earth connection. etc., complete complying with standard specification and as directed by the Departmental officers 208 Supply and providing cable end termination of 3½ x185sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete etc., complete complying with standard specification and as directed by the Departmental officers 209 Supply and fixing of LT cable route indicator with suitable angle not less than 38mm x 38mm 6mm and 0.6mtr long excavation of earth to a depth of 0.6 mtr and concreting the ground level and making good of the ground as directed by the departmental officers. etc., complete complying with standard specification and as directed by the Departmental officers 210 Earthing as per the ISI specification with an earth electrode of 2.1mt class B GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry. etc., complete complying with standard specification and as directed by the Departmental officer 211 Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection. etc., complete complying with standard specification and as directed by the Departmental officers 212 Supply and Run of 1 of No.8 SWG copper wire for earth connection. etc., complete complying with standard specification and as directed by the Departmental officers 213 Supply and fixing of 200 A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with earth connection only. etc., complete complying with standard specification and as directed by the Departmental officers 214 Supply and clamping of 3 1/2 x 70 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps.etc., complete complying with standard specification and as directed by the Departmental officers 215 Supply and fixing of brass cable gland for 3 1/2 x 70 sqmm PVC armoured LTUG cable with earth connection. etc., complete complying with standard specification and as directed by the Departmental officers 216 Supply and providing cable end termination of 3 1/2 x 70 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete etc., complete complying with standard specification and as directed by the Departmental officers 217 Supply and fixing of 32A TPN MC switch on suitable angle iron frame work with MS cable entry box with earth connection only. etc., complete complying with standard specification and as directed by the Departmental officers 218 Supply and fixing of 4 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 No 32A 4P MCB as incoming and 12 Nos 6A to 32A SP MCB as outgoing in flush with wall with Earth connection only. Higher End etc., complete complying with standard specification and as directed by the Departmental officers 219 Supply and Laying of 31/2 x 25 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. etc., complete complying with standard specification and as directed by the Departmental officers 220 Supply and clarnping of 31/2 x 25sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps. etc., complete complying with standard specification and as directed by the Departmental officers 221 Supply and fixing of brass cable gland for 31/2 x 25sq.mm. LTUG armoured cable with earth connection etc., complete complying with standard specification and as directed by the Departmental officers 222 Supply and fixing of 250 Amps TPN sheet double break switch with HRC fuse and neutral on suitable angle iron frame work with MS cable entry boxes and with earth connection only etc., complete complying with standard specification and as directed by the Departmental officers 223 Supply and Errection of 2Nos. 250A TPN switch disconnector fuse units interior only with HRC fuse Double Break in the existing MV panel board made up of 16 SWG CRCA sheet steel with supply and fixing of the following interior mounting fuse switch with HRC fuses arrangement in two Vertical rows with one switch over the other, with a central bus bar chamber and two ends one on each side next to the fuse switch chamber and cable alloy conforming to IE rules.The bus bar chamber will consist of suitable size of tinned copper flat for phase and neutral buses on epoxy moulded bus insulated at proper and sufficient spacing between the buses as per IE Rules. This bus bar chamber should be segregated from the adjacent chamber by providing hylem sheet of suitable thickness as partisans. 2 Nos 50x6 mmand 2 Nos 25x3mm tinned copper flats should be provided all round the panel for earth bus.The capacity of the switches size of incoming and out going cable the place to which the supply is feed shall be mounted on switch chamber with necessary earth connection etc., complete complying with standard specification and as directed by the Departmental officers 224 Supply and Fixing of AC/DC 2 Module Gang Bell suitable for 230Volts 50c/s single phase AC supply on suitable angle iron frame work with 1/2 module flush mounting box (GI) and 2 module white cover plate with frame (Plastic) with 6A Bell Push-1 Module with necessary connection. (Higher End) etc., complete complying with standard specification and as directed by the Departmental officers 225 Supply and run of 2 of 1.5 sq mm (22/0.3) PVC insulated SC unsheathed Cu Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling and making good of the concealed portion with painting of suitable colour etc., complete complying with standard specification and as directed by the Departmental officers