Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 01-12-2025 | date extension | Date | 05-12-2025 |
| 2 | 20-11-2025 | Prebid meeting minutes | Other | 01-12-2025 |
| Sl. No. | Item Description |
| 1 | SITE CLEARING AND DEVELOPMENT |
| 2 | Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth |
| 3 | Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth |
| 4 | Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyond 120 cm girth up to and including 240 cm girth |
| 5 | Cutting of earth by mechanical means (Hydraulic excavator)/manual means over areas for leveling the land to the required formation level, including getting out and disposal of excavated earth lead upto 50 m, sufficient arrangements to be made for preserving the top soil for landscaping purposes as directed by Engineer-in-charge. |
| 6 | Cutting of hard laterite by mechanical means (Hydraulic excavator)/manual means over areas for leveling the land to the required formation level, including getting out and disposal of excavated earth lead upto 50 m, as directed by Engineer-in-charge. |
| 7 | Open timbering in trenches including strutting and shoring complete ( measurements to be taken of the face area timbered ):Depth not exceeding 1.5 m |
| 8 | Open timbering in trenches including strutting and shoring complete ( measurements to be taken of the face area timbered ):Depth exceeding 1.5 m but not exceeding 3 m |
| 9 | CONSTRUCTION OF BUILDING |
| 10 | Cutting of hard laterite by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift from 3.0m to 4.5m, or part thereof in excavation / banking excavated or stacked materials. as directed by Engineer-in-charge. |
| 11 | Cutting of hard laterite by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift from 4.5m to 6.0m, or part thereof in excavation / banking excavated or stacked materials. as directed by Engineer-in-charge. |
| 12 | Cutting of hard laterite by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift from 6.0m to 7.5 m or part thereof in excavation / banking excavated or stacked materials. as directed by Engineer-in-charge. |
| 13 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size) and apply one coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 14 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 15 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) |
| 16 | Providing and laying in position machine batched and machine mixed design M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability and also include integral water proofing liquid admixture for concrete as per the direction of Engineer - in- charge. All work above All works upto plinth level |
| 17 | Providing and laying in position machine batched and machine mixed design M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability and also include integral water proofing liquid admixture compound as per the direction of Engineer - in- charge. All work above Plinth level up to floor V |
| 18 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate,retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. All work above plinth level upto floor V level |
| 19 | Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete |
| 20 | Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 21 | Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 22 | Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 23 | Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts |
| 24 | Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) |
| 25 | Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 26 | Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges |
| 27 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 28 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo - Mechanically Treated bars of grade Fe-500D or more |
| 29 | Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc must contain minimum 40% fly ash by weight etc complete. |
| 30 | Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure above floor two level up to floor V level thickness 20cm and above in: CM 1:6 ( 1 cement :6 coarse sand) etc must contain minimum 40% fly ash by weight etc complete. |
| 31 | Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding, must contain minimum 40% fly ash by weight etc complete. |
| 32 | Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding, must contain minimum 40% fly ash by weight etc complete. |
| 33 | Providing and laying autoclaved aerated cement blocks masonry with required thickness as per architectural drawing, having minimum 40% fly ash content by weight, AAC blocks in super structure above floor 2 level up to floor V level in cement mortar 1:4 (1 cement :4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. |
| 34 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 35 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 36 | Stone tile work for wall lining upto 10 m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade.8 mm thick (mirror polished and machine cut edge) Granite stone of any colour and shade |
| 37 | Providing and laying vitrified floor tiles size 600mm X 1200 mm (Glossy Finish) (Kajaria or equivalent) in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete including skirting, riser of steps, etc complete as per direction of Engineer-in-charge. Tile size 600mm X 1200 mm |
| 38 | Providing and laying vitrified floor tiles 800x800 mm Matt finish (Kajaria or equivalent) in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing , in skirting, riser of steps, etc complete as per direction of Engineer-in-charge. Tile size 800mm X 800 mm |
| 39 | Providing and fixing Ist quality ceramic glazed wall tiles (Kajaria or equivalent) of size 600x600 conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand),and Grouting the joints of wall tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge |
| 40 | Providing and laying Antiskid Ceramic floor tiles (Kajaria or equivalent) of size 600x600 mm or more(thickness to be specified by the manufacturer) of first quality, with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, in floors, laid with a 20 mm thick cement mortar 1:4(1 cement 4 coarse sand) including grouting of joints of 3 mm using epoxy grout mix of 0.7 kg of organic coated filler or desired shade (0.1 kg of hardener and 0.2 kg of resin per kg)including filling /grouting and finishing complete as per direction of engineer in charge Size of Tile 600x600 mm |
| 41 | Providing and laying Antiskid vitrified floor tiles size 600mm X 1200 mm (Kajaria or equivalent) in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete including skirting, riser of steps, etc complete as per direction of Engineer-in-charge. Tile size 600mm X 1200 mm |
| 42 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 43 | Providing and fixing to existing door frames. 30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge. |
| 44 | Providing and fixing factory made uPVC white colour 5mm toughened glass SHGC < 0.56 and VLT >=51% fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 � 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape &size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge.Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47x 68 mm both having wall thickness of 1.9 0.2 mm and single glazing bead of appropriate dimension. (Area up to 0.75 sqm.), including 5mm toughened glass SHGC < 0.56 and VLT >=51% and water proof silicon sealant. |
| 45 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows with 5mm toughened glass SHGC < 0.56 and VLT >=51% comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Including single glazing bead / double glazing bead of appropriate dimension and weather proof silicon sealent. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Casement window double panels with top fixed with S.S. friction hinges (350 x19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm &mullion 47 x 68 mm all having wall thickness of 1.9 � 0.2 mm and single glazing bead of appropriate dimension. ( Area of window upto 2.50 sqm). |
| 46 | Providing and fixing factory made uPVC white colour sliding glazed window with 5mm toughened glass SHGC < 0.56 and VLT >=51%upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) over backer rod touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Including glass panes, weather proof silicon sealent Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track two panels sliding window with 5mm toughened glass SHGC < 0.56 and VLT >=51%upto 1.50 m made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) |
| 47 | Providing and fixing factory made uPVC white colour sliding glazed window with 5mm toughened glass SHGC < 0.56 and VLT >=51% upto 1.80 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Including glass panes, weather proof silicon sealent Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Three track three panels sliding window with 5mm toughened glass SHGC < 0.56 and VLT >=51%made of (big series) frame 116 x 45 mm& sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and singleglazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) |
| 48 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) |
| 49 | Plastering with Cement mortar 1:4 ( 1 cement : 4 fine sand), 12 mm thick one coat for Out side walls, including cost and conveyance of all materials, Scaffolding and labour, floated hard and trowelled smooth, watering, curing etc. complete. as directed by the Engineer in charge (up to 10m height) |
| 50 | Plastering with Cement mortar 1:4 ( 1 cement : 4 fine sand), 12 mm thick one coat for Out side walls, including cost and conveyance of all materials, Scaffolding and labour, floated hard and trowelled smooth, watering, curing etc. complete. as directed by the Engineer in charge (10m - 13m height) |
| 51 | Plastering with Cement mortar 1:4 ( 1 cement : 4 fine sand), 12 mm thick one coat for Out side walls, including cost and conveyance of all materials, Scaffolding and labour, floated hard and trowelled smooth, watering, curing etc. complete. as directed by the Engineer in charge (13m - 16m height) |
| 52 | Plastering with Cement mortar 1:4 ( 1 cement : 4 fine sand), 12 mm thick one coat for Out side walls, including cost and conveyance of all materials, Scaffolding and labour, floated hard and trowelled smooth, watering, curing etc. complete. as directed by the Engineer in charge (16m - 19m height) |
| 53 | Plastering with Cement mortar 1:4 ( 1 cement : 4 fine sand), 12 mm thick one coat for Out side walls, including cost and conveyance of all materials, Scaffolding and labour, floated hard and trowelled smooth, watering, curing etc. complete. as directed by the Engineer in charge (19m - 22m height) |
| 54 | 12 mm cement plaster finished with a floating coat of neat cement of mix: 1:4 ( 1 cement : 4 fine sand) |
| 55 | 9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete |
| 56 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix:1:3 ( 1 Cement : 3 fine sand) |
| 57 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 58 | Wall painting with premium acrylic emulsion paint of interior grade, low VOC content less than 50g/l for flat finish and less than 150 g/l for non-flat finish and must be lead-free of approved brand and manufacture, including applying additional coats wherever required o achieve even shade and colour. Two coats, including applying one or two priming coats with water thinnable cement primer on walls primer of less than 50g/l for flat finish and less than 150 g/l for non-flat finish and must be lead-free of approved brand and manufacture. |
| 59 | Finishing walls with Acrylic Smooth Exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sq m), less than 50g/l for flat finish and less than 150 g/l for non-flat finish and must be lead-free of approved brand and manufacture etc. complete. |
| 60 | Providing & fixing suspended ceiling in flat, curved or other shapes as indicated in thedrawing including fixing of G I. perimeter channels of size 0.55mm thick having one flange of 20mm andanother flange of 30mm and web of 27mm along with perimeter of ceiling, screw fixed to be onto brick wall /partition with the help of nylon sleeves and screws, at 610mm centers. Then suspending G I. intermediatechannels of size 45mm, 0.9mm thick with two flanges of 15mm each from the soffit at 1220mm centers withceiling angle of width of 25mm X 10mm X 0.55mm thick fixed to soffit with Gig. cleat and steel expansionfasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip andindirection perpendicular to the intermediate channel at 457mm centers. all sections are gyprocultranew12.5 mm tapered edge Standard Gypsum board (confirming to IS: 2095- 1982 & 2542-1981)gyproc or equivelant is then screw fixed to ceiling section with 25mm drywall screws at 230mmcenters. Screw fixing is done mechanically either with screw driver or drilling machine with suitableattachment. Finally the standard gypsum boards are to be jointed and finished so as to have a flush lookwhich includes filling and finishing the tapered and square edges of the board with jointing compound, Jointpaper tape. Thecolour, shade and texture should be approved by Architect. Rate shall be include with allmaterial shifting with all lead and lifts, masking for fixtures& frames, cutting light & AC cut outs &temporary stand & scaffolding where ever required as per instruction by architect. |
| 61 | Supplying and fitting LESSO EITI /ALUPLAST /KOMMERLING or similar type uPVC double door of white colour for door opening 1.8 X 2.25 m , the door frames of size as directed by the engineer in charge has to be placed with a steel frame work of 2mm thick steel reinforcement inside upvc frame and glazing of 12mm toughened glass including fixing hinges,friction stays, screws, silicon sealant, single point lock/dead lock (godrej), handle, pedal, automatic door closer(godrej), including making charges,conveyance charges, installation charges etc complete as directed by the engineer in-charge |
| 62 | Supplying and fitting LESSO EITI /ALUPLAST /KOMMERLING or similar type uPVC Double Shutter Door , Wooden Finish with a fixed portion above the shutter area and single panel fixed portion on either side of the shutter, the door frames of size as directed by the engineer in charge has to be placed with a steel frame work of 2mm thick steel reinforcement inside upvc frame and glazing of 12mm toughened glass including fixing hinges, friction stays, screws, silicon sealant, single point lock/dead lock (godrej), handle, pedal, automatic door closer (godrej), including making charges, conveyance charges, installation charges etc complete as directed by the engineer in-charge |
| 63 | Supplying and fitting LESSO EITI /ALUPLAST /KOMMERLING or similar type uPVC double door for door opening 5.7 X 3.0 m of wooden finish with a fixed portion above the shutter area and double panel fixed portion on either side of openable shutter area, the door frames of size as directed by the engineer in charge has to be placed with a steel frame work of 2mm thick steel reinforcement inside upvc frame and glazing of 12mm toughened glass including fixing hinges,friction stays, screws, silicon sealant, single point lock/dead lock (godrej), handle, pedal, automatic door closer(godrej), including making charges,conveyance charges, installation charges etc complete as directed by the engineer in-charge |
| 64 | Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m2) suita2ble for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m2 . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded |
| 65 | Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately |
| 66 | Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealent shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm). |
| 67 | Providing and fixing factory made uPVC white colour casement/ Casement cum fixed Single Shutter/ glazed door 5mm toughened glass SHGC < 0.56 and VLT >=51% comprising of uPVC multi-chambered frame, sash and mullion(where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length(shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinge sand one handle on each side of panels along with zinc plated mild steel multipoint locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Including single glazing bead / double glazing bead of appropriate dimension and weather proof silicon sealent. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion67 x 80 mm all having wall thickness of 2.3 +/- 0.2 mm and single glazing bead /double glazing bead of appropriate dimension.(Area of door upto 2.50 sqm) |
| 68 | Supplying, commissioning, and erecting Godrej Defender Plus Strong Room Door with Grill Gate BIS (Class B) (H:2128mm W:1254mm D:192mm) TRTL 30 FR 30, including conveyance labour charge etc complete. |
| 69 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 70 | Providing and fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including providing and fixing top and bottom all patch fittings all complete as per direction of Engineer-in-charge |
| 71 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) |
| 72 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 73 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness |
| 74 | Providing and fixing aluminium mesh above aluminium partition work, including labour ,materials, conveyance etc complete as per the architectural drawings and the directions of Engineer - in -Charge. |
| 75 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides |
| 76 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 77 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 78 | Providing and fitting SS fan hook 10mm or nearest available size bend to shape with hooked ends. |
| 79 | Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc |
| 80 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). |
| 81 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin- Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub-head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories 1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr” 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.” 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testing method for a range upto 2000 ml” 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm” 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml” |
| 82 | Providing, assembling and supplying vision glass panels (IGUs) with SHGC ≤ 0.56 and VLT ≥ 51%, comprising of hermetically-sealed 6-12- 6 mm insulated glass vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance ( VLT ≥ 51%), Light reflection internal 10 to 15%, light reflection external 10 to 20 %, Solar Heat Gain Coefficient (≤ 0.56) and U value of 5.6 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. |
| 83 | Extra for openable side / top hung vision glass panels with Solar Heat Gain Coefficient of SHGC ≤ 0.56 and VLT ≥ 51% vision panel units of size and shape as required and specified,including providing and supplying at site allaccessories and hardwares for the openable panels as specified and of the approved make such asheavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles,buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts,washers etc. allcomplete as per the Architectural drawings, as per the approved shop drawings, as specified and asdirected by the Engineer-in-Charge. |
| 84 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts,locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer . |
| 85 | Providing Decorative wall with Terracotta Jally work of best quality (the exact pattern and quality to be approved by the engineer in charge) and the construction has to be done according to the architectural drawings in the courtyard space.including labour charge, adhesive used have low VOC content. |
| 86 | Providing, fabricating and supplying and fixing Perforated HPL sheet (6mm thickness) of approved make for all required portions of the building with ALSTONE/ GREENLAM CLADS/ FUNDERMAX or equivalent having 12 years Guarantee, colour of approved shades made out of 6mm thick, the sheet should be fixed to a frame work made of TATA GI pipe (2mm thickness,1.5\"X1.5\" including including application of primer to steel and synthetic enamel paint application) with SS screws to SS L / U clamp. The sheet should be cut in to sizes, chambered,using standard rolling machine to level the sheet with out leaving any mark on the sheet .The pre-fabricated frame work using 1.5\"X1.5\" placed horizontally and vertically with a spacing of 600mm and 1220 mm to be fixed on the wall or floor beams with normal Anchor bolt M8, Screw(13x6) etc. The Contractor shall provide cladding, having all the performance characteristics as per the Architectural drawings, item description as specified in the approved drawings, directed by the Engineer-in-Charge. The rate shall include all labour, material cost and conveyance of all materials to site, lead, lift, labour charge for erection, hire charges, for scaffolding, sealant if necessary in the site the sealant should be with low VOC, T&P, other incidental charges including wastage, enabling temporary services all fitting fixers etc. all complete etc completed as directed by the engineer in charge. However, for the purpose of payment, only the actual area on the external face shall be measured in sqm. up to two decimal places. |
| 87 | Providing, fabricating and supplying and fixing Aluminium fin louvers (3mm thickness) of approved make for all required portions of the building with ALSTONE/ GREENLAM CLADS/ FUNDERMAX or equivalent having 12 years Guarantee, colour of approved shades made out of 6mm thick, the sheet should be fixed to a frame work made of TATA GI pipe (2mm thickness) ,1.5\"X1.5\" including application of primer to steel and synthetic enamel application ) with SS screws and SS L / U clamp. The sheet should be cut in to sizes , chamfered, using standard rolling machine to level the sheet with out leaving any mark on the sheet .The pre fabricated frame work using 1.5\"X1.5\" placed horizontally and vertically with a spacing of 600mm and 1220 mm to be fixed on the wall or floor beams with normal Anchor bolt M8, Screw(13x6) etc .The Contractor shall provide cladding, having all the performance characteristics as per the Architectural drawings, item description as specified in the approved drawings, directed by the Engineer-in-Charge. The rate shall include all labour, material cost and conveyance of all materials to site, lead, lift, labour charge for erection, hire charges, for scaffolding, T&P, other incidental charges including wastage, enabling temporary services all fitting fixers etc. all complete etc completed as directed by the engineer in charge,. However, for the purpose of payment, only the actual area on the external face shall be measured in sqm. up to two decimal places. |
| 88 | RETAINING WALL |
| 89 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 90 | Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 91 | Providing and laying in position machine batched and machine mixed design M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability and also include integral water proofing liquid admixture for concrete as per the direction of Engineer - in- charge. All work above All works upto plinth level |
| 92 | Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 93 | Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 94 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 95 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2 |
| 96 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) |
| 97 | Providing and laying in position machine batched and machine mixed design M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability and also include integral water proofing liquid admixture for concrete as per the direction of Engineer - in- charge. All work above All works upto plinth level |
| 98 | Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 99 | Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 100 | Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 101 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 102 | Plastering with Cement mortar 1:3, 12mm thick two coats and adding water proofing compound best quality ( Dr. Fixit water proofing compound or equivalent in cement mortar and flushing coat ) available in the market inside walls of toilet rooms, inside of water tanks, Retaining wall, over Sunshade, Roof slab, Sump, Rainwater, Pump room etc etc. including cost and conveyance of all materials and labour, floated hard and trowelledsmooth, watering, curing etc. complete for all floors. |
| 103 | Providing 600x600mm(50 Kg or nearest available weight) size CI manhole cover with frame including locking arrangements to the top of the cover slab as directed by the dept. Engineers, etc. complete. |
| 104 | GATE AND COMPOUND WALL |
| 105 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 106 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) |
| 107 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 108 | Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 109 | Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 110 | Hollow block masonry using pre cast block (Factory made) of size 40x20x20 cm or nearest available size confirming to IS 2185 part 1 of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete |
| 111 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level |
| 112 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more |
| 113 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 114 | Finishing walls with Acrylic Smooth Exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sq m), less than 50g/l for flat finish and less than 150 g/l for non-flat finish and must be lead-free of approved brand and manufacture etc. complete.DeleteAdd Specification Below |
| 115 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 116 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture . |
| 117 | INCINERATOR |
| 118 | Supplying and installing Incinerator ETI-150 kg with volume 55 cu ft for treating 150 kg/hr, Single chamber (combustion chamber made of fine grain steel plates,quenched and tougher and higher impact energy) including fabrication, with thermal insulation refractory super cement inside, inner face lining refractory fire brick (IS 8), outer face lining with refractory ceramic fire blanket, outer layer of Aluminium cladding,waste loading door, stair with platform for waste loading,ash chamber with door, cleaning and inspection door, oxygen inlet ports, stainless steel chimney of thickness 8 mm, fasteners, chamber cleaning brush, quality epoxy and weather resist painting , transportation and erection. |
| 119 | BORE WELL |
| 120 | Boring / drilling bore well of required dia for casing / strainer pipe, by suitable method prescribed in IS: 2800 ( part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools plants & machineries required for the job, all complete as per direction of Engineer - in- Charge, upto 90 metre depth below ground level.All types of soil400 mm dia |
| 121 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS : 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer- in- Charge.200 mm nominal size dia |
| 122 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- charges |
| 123 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge |
| 124 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 125 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000x450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforation @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer - in- charge. |
| 126 | LANDSCAPING |
| 127 | Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge |
| 128 | Filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and leveling (cost of supplying earth and sludge or manure and mixing excluded). |
| 129 | Supplying and planting of Fiddle Fig or equivalent plants approved by the departmental officers in the ground, mixing the soil with manure, planting the saplings, backfilling the trench, watering etc. |
| 130 | Supplying and planting of Peace Lilly or equivalent plants approved by the departmental officers in the ground, mixing the soil with manure, planting the saplings, backfilling the trench, watering etc. |
| 131 | Supplying and planting of Peace Lilly or equivalent plants approved by the departmental officers in the ground, mixing the soil with manure, planting the saplings, backfilling the trench, watering etc. |
| 132 | Supplying and planting of Calathea or equivalent plants approved by the departmental officers in the ground, mixing the soil with manure, planting the saplings, backfilling the trench, watering etc. |
| 133 | Supplying and planting of Heliconia or equivalent plants approved by the departmental officers in the ground, mixing the soil with manure, planting the saplings, backfilling the trench, watering etc. |
| 134 | Supplying and planting of Calathea Lutea or equivalent plants approved by the departmental officers in the ground, mixing the soil with manure, planting the saplings, backfilling the trench, watering etc. |
| 135 | Supplying and planting of Finger Palm or equivalent plants approved by the departmental officers in the ground, mixing the soil with manure, planting the saplings, backfilling the trench, watering etc. |
| 136 | Supplying and planting of canopy tree saplings approved by the departmental officers in the ground, mixing the soil with manure, planting the saplings, backfilling the trench, watering etc. |
| 137 | SEWAGE TREATMENT PLANT |
| 138 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) |
| 139 | Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete |
| 140 | Centering and shuttering including strutting, etc. and removal of form for: Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 141 | Centering and shuttering including strutting, etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform |
| 142 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 143 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge.All wiork upto plinth level |
| 144 | Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster |
| 145 | Supply, installation, testing and commissioning of Sewage Treatment Plant (MBBR Type) of 30 KLD capacity with Ultra Filter. The work is inclusive of all necessary Plumbing and Electrical works including electrical control panel, Cabling work with all accessories required for complete installation as per the detailed technical specifications. |
| 146 | Supply and filling around the soak pit with 6mm metal as directed by the departmental officers at site |
| 147 | Providing 900x900mm(100 Kg or nearest available weight) size CI manhole cover with frame including locking arrangements to the top of the cover slab as directed by the dept. Engineers, etc. complete. |
| 148 | BIO WASTE MANAGEMENT |
| 149 | Providing and supplying Bio Composting Incubator / bin of Capacity : 30 Liter per day, 40\" Dia , 50\" height,Feeding from Top & Romoval from the bottom , Material: LLDPE (Plastic), Supply, including 3 Nos of Waste Bin & 3 buckets for feeding by removing watery portion in waste, Coir Pith 500 Liter & Start-up etc complete. |
| 150 | SIGNAGE |
| 151 | Designing, fabricating, installing and fixing in position of Titanium gold signage (Government of Kerala logo 1 nos and lettering in malayalam (Government of Kerala ) including design and preparation of shop drawings for the specified design, including fixing ss cleats and screws etc. and including cutting to size and shape wherever required and finishing complete as per direction of Engineer-in-charge. |
| 152 | Designing, fabricating, installing and fixing in position of Titanium gold signage (Government of Kerala logo 1 nos and lettering in malayalam (Government of Kerala ) including design and preparation of shop drawings for the specified design, including fixing ss cleats and screws etc. and including cutting to size and shape wherever required and finishing complete as per direction of Engineer-in-charge. |
| 153 | Designing, fabricating, installing and fixing in position of Titanium gold signage lettering in malayam, building name at top of the building (2nos)including design and preparation of shop drawings for the specified design, including fixing ss cleats and screws etc. and including cutting to size and shape wherever required and finishing complete as per direction of Engineer-in-charge. |
| 154 | Designing, fabricating, installing and fixing in position of Titanium gold signage lettering, KSHB & KIIFB logo, name of work in english lettering at entrance including design and preparation of shop drawings for the specified design, including fixing ss cleats and screws etc. and including cutting to size and shape wherever required and finishing complete as per direction of Engineer-in-charge. |
| 155 | Providing and fixing 4mm form sheet with UV sticker for Environmental, Informational, Toilet signage, including labour charge, fixing charge etc complete. |
| 156 | SANITARY FIXTURES, BATH FITTINGS AND ACCESSORIES |
| 157 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre /8 litres), including seat cover, and cistern fittings, nuts bolts and gasket etc complete. |
| 158 | Supplying, installing, testing & commissioning at site in position of sanitary fixtures for handicapped toilet including one number white vitreous china wall/floor mounted water closet with UF soft close seat cover and cistern, wash basin, one pair mounting brackets, one number elbow operated pillar cock and all other related fittings like waste coupling, one number hinged rail, 76 cm long & 4 sets of of grab rails, each of 60cm, long etc. designed for people with special needs comes with as per manufactures specification including cutting and making good the walls and floors wherever required as per drawing and as directed by Engineer in charge. |
| 159 | Providing and fixing white vitreous china water closet squatting pan ( Indian type):Orissa pattern W.C. pan of size 580x440 mm |
| 160 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes with a flush rate upto 1.5 LPF respectively. |
| 161 | Supplying, installing, testing & commissioning at site in position colour or white vitreous china following Wash Basin of approved make with C.I. brackets, 32 mm C.P. brass waste of standard pattern , with flow rate of 4 LPM at 45 psi with all accessories required for complete installation, including painting of fittings and brackets, cutting and making good the walls wherever require with all accessories required for complete installation as per the direction of Engineer in charge. Wash basin - Counter Top |
| 162 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps with flow rate of 4 LPM at 45 psi pressure, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x400mm with single 15 mmC.P.brasspillar taps |
| 163 | Supplying, installing, testing & commissioning at site in position of following basin / wall mixer / pillar Cock / Bib Cock / Sink Cock with exposed part kit and aerator, Connecting legs & wall flanges, 15mm. nominal bore with flow rate of 4 LPM at 45 psi pressure, including all necessary accessories required for complete installation, all as per manufacturer\"s instruction and to the approval of the Engineer-in-charge. |
| 164 | Supplying, installing, testing & commissioning at site in position approved make C.P. Ablution Spray Health Faucet with wall hook, 8 mm dia, 1 meter long spirochrome flexible tube, back flow preventer, etc. necessary nuts with all accessories required to complete including cutting and making good the walls wherever required and as per the direction of Engineer in charge. |
| 165 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore |
| 166 | Supplying, installing, testing & commissioning at site in position approved make Soap Dispenser etc. complete with all accessories required and as per the direction of Engineer in charge. |
| 167 | Supplying, installing, testing & commissioning at site in position approved make CP Towel Ring with CP wall flange etc. complete with all accessories required and as per the direction of Engineer in charge |
| 168 | Supplying, installing, testing & commissioning at site in position approved make following Flexible Braided Connectors, 15mm. nominal bore, 450mm. Long with higher thermal stability for cold and hot water, etc. complete with all accesories required and as per the direction of Engineer in charge. |
| 169 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 170 | Supplying, installation, testing, and commissioning of Water Meter with direct reading dial in kilo litres, with all integral parts made of GM/Brass, including flanged distance pieces and all necessary fittings for easy removal. For sizes up to 50 mm – screwed connection; above 50 mm – flanged connection. Class B type. Complete in all respects as per specifications, drawings, and the direction of the Engineer-in-Charge. Water meter 20 mm dia. |
| 171 | Supplying, installation, testing, and commissioning of Water Meter with direct reading dial in kilo litres, with all integral parts made of GM/Brass, including flanged distance pieces and all necessary fittings for easy removal. For sizes up to 50 mm – screwed connection; above 50 mm – flanged connection. Class B type. Complete in all respects as per specifications, drawings, and the direction of the Engineer-in-Charge. Water meter 25 mm dia. |
| 172 | Supplying, installation, testing, and commissioning of Water Meter with direct reading dial in kilo litres, with all integral parts made of GM/Brass, including flanged distance pieces and all necessary fittings for easy removal. For sizes up to 50 mm – screwed connection; above 50 mm – flanged connection. Class B type. Complete in all respects as per specifications, drawings, and the direction of the Engineer-in-Charge. Water meter 32 mm dia. |
| 173 | INTERNAL DRAINAGE |
| 174 | Supplying, laying, Testing and commissioning at site in position uPVC pipe of 32 mm OD, 10Kg/sq.cm (IS:4985) including injection moulded fittings with bosses where required eg 90 Degree bend, 45 Degree bends, \"Y\", couplings, adapters & clamping with Universal clamps 1metre spacing, Anchor fasteners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site(For sunken drain - Internal) 32 mm OD |
| 175 | Supplying, laying, Testing and commissioning at site in position uPVC pipe of 6 Kg/sq.cm (IS:4985) including injection moulded fittings with bosses where required eg 90 Degree bend, 45 Degree bends, \"Y\", couplings, adapters & clamping with Universal clamps/U bolt 1metre spacing, Anchor fasteners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site(For Soil & Waste pipes -Internal). 50mm dia OD uPVC pipe of 6Kg/sq.cm |
| 176 | Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type B (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site(For Soil & Waste pipes -Internal). 75 mm OD |
| 177 | Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type B (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters, rodding eye & clamping with Universal clamps, Anchor fastners (8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site(For Soil & Waste pipes -Internal).110 mm OD |
| 178 | Supplying, laying, Testing and commissioning at site in position uPVC pipe (SWR) of63mm dia OD uPVC pipe of 4Kg/sq.cm (IS:4985) including injection moulded fittings with bosses whererequired eg 90 Degree, 45 Degree bends, Y, couplings, adapters, rodding eye & clamping with Universalclamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approvedadhesive by manufactures including cutting and making good the walls and floors or surface mounted withclamps as required at site.(For Vent pipes -Internal) 63mm dia. |
| 179 | Supplying, laying, Testing and commissioning at site in position Ring uPVC pipe (SWR) of Type B (IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735) fittings with bosses where required eg. Door tees, Door bends, \"Y\", bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Universal clamps, Anchor fastners, Threaded rod, nuts, washers etc complete, including cutting and making good the walls and floors as required at site.(For Vertical & Horizontal Shaft piping). 75mm OD |
| 180 | Supplying, laying, Testing and commissioning at site in position Ring uPVC pipe (SWR) of Type B (IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735) fittings with bosses where required eg. Door tees, Door bends, \"Y\", bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Universal clamps, Anchor fastners, Threaded rod, nuts, washers etc complete, including cutting and making good the walls and floors as required at site.(For Vertical & Horizontal Shaft piping). 110mm OD |
| 181 | Supplying, installing, testing & commissioning at site in position 110mm dia deep seal PVC P Trap with boss tee and access cap including all necessary fittings and supports complete. |
| 182 | WATER SUPPLY |
| 183 | Supplying, laying, Testing and commissioning at site in position uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, with all specials etc. of approved make, complete with all necessary Fittings including elbows, unions, tees, reducers, couplings, nipples, brass threaded fittings, etc. for jointing pipes by solvent welding using manuacturer recomended solvent, exposed on walls complete with clamping in position with exposed on walls complete with clamping in position with G.I. \"U\" bolts (8 mm thick) on G.I. slotted rails (1.6 mm thick), Rail legs (2.5 mm thick) of approved make, as per specification, drawing and direction of Engineer in charge.Internal work - Exposed on wall - Ceiling and Shaft-20 mm dia. Pipes. |
| 184 | Supplying, laying, Testing and commissioning at site in position uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, with all specials etc. of approved make, complete with all necessary Fittings including elbows, unions, tees, reducers, couplings, nipples, brass threaded fittings, etc. for jointing pipes by solvent welding using manuacturer recomended solvent, exposed on walls complete with clamping in position with exposed on walls complete with clamping in position with G.I. \"U\" bolts (8 mm thick) on G.I. slotted rails (1.6 mm thick), Rail legs (2.5 mm thick) of approved make, as per specification, drawing and direction of Engineer in charge.Internal work - Exposed on wall - Ceiling and Shaft - 25 mm dia. Pipes. |
| 185 | Supplying, laying, Testing and commissioning at site in position uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, with all specials etc. of approved make, complete with all necessary Fittings including elbows, unions, tees, reducers, couplings, nipples, brass threaded fittings, etc. for jointing pipes by solvent welding using manuacturer recomended solvent, exposed on walls complete with clamping in position with exposed on walls complete with clamping in position with G.I. \"U\" bolts (8 mm thick) on G.I. slotted rails (1.6 mm thick), Rail legs (2.5 mm thick) of approved make, as per specification, drawing and direction of Engineer in charge.Internal work - Exposed on wall - Ceiling and Shaft-32 mm dia. Pipes. |
| 186 | Supplying, laying, Testing and commissioning at site in position uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, with all specials etc. of approved make, complete with all necessary Fittings including elbows, unions, tees, reducers, couplings, nipples, brass threadedfittings, etc. for jointing pipes by solvent welding using manuacturer recomended solvent, exposed on wallscomplete with clamping in position with exposed on walls complete with clamping in position with G.I. \"U\"bolts (8 mm thick) on G.I. slotted rails (1.6 mm thick), Rail legs (2.5 mm thick) of approved make, as perspecification, drawing and direction of Engineer in charge.Internal work - Exposed on wall - Ceiling andShaft-40 mm dia. Pipes |
| 187 | Supplying, laying, Testing and commissioning at site in position uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, with all specials etc. of approved make, complete with all necessary Fittings including elbows, unions, tees, reducers, couplings, nipples, brass threaded fittings, etc. for jointing pipes by solvent welding using manuacturer recomended solvent, exposed on walls complete with clamping in position with exposed on walls complete with clamping in position with G.I. \"U\" bolts (8 mm thick) on G.I. slotted rails (1.6 mm thick), Rail legs (2.5 mm thick) of approved make, as per specification, drawing and direction of Engineer in charge.Internal work - Exposed on wall - Ceiling and Shaft- 50 mm dia. Pipes. |
| 188 | Supplying, laying, Testing and commissioning at site in position uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, with all specials etc. of approved make, complete with all necessary Fittings including elbows, unions, tees, reducers, couplings, nipples, brass threaded fittings, etc. for jointing pipes by solvent welding using manuacturer recomended solvent, exposed on walls complete with clamping in position with exposed on walls complete with clamping in position with G.I. \"U\" bolts (8 mm thick) on G.I. slotted rails (1.6 mm thick), Rail legs (2.5 mm thick) of approved make, as per specification, drawing and direction of Engineer in charge.Internal work - Exposed on wall - Ceiling and Shaft- 65 mm nominal outer dia. Pipes. |
| 189 | Supplying, laying, Testing and commissioning at site in position uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, with all specials etc. of approved make, complete with all necessary Fittings including elbows, unions, tees, reducers, couplings, nipples, brass threaded fittings, etc. for jointing pipes by solvent welding using manuacturer recomended solvent, exposed on walls complete with clamping in position with exposed on walls complete with clamping in position with G.I. \"U\" bolts (8 mm thick) on G.I. slotted rails (1.6 mm thick), Rail legs (2.5 mm thick) of approved make, as per specification, drawing and direction of Engineer in charge.Internal work - Exposed on wall - Ceiling and Shaft- 80 mm nominal outer dia. Pipes. |
| 190 | Supplying, Installing, Testing & Commissioning at site in position of approved make full way lever operated Forged Brass Ball valve (PN 25) of brass body with forged brass hard chrome plate with all necessary fittings including Male Adapter (Brass Threads) in position as per specification, drawing and direction of Engineer in charge.20 mm dia. |
| 191 | Supplying, Installing, Testing & Commissioning at site in position of approved make full way lever operated Forged Brass Ball valve (PN 25) of brass body with forged brass hard chrome plate with all necessary fittings including Male Adapter (Brass Threads) in position as per specification, drawing and direction of Engineer in charge. 25 mm dia. |
| 192 | Supplying, Installing, Testing & Commissioning at site in position of approved make full way lever operated Forged Brass Ball valve (PN 25) of brass body with forged brass hard chrome plate with all necessary fittings including Male Adapter (Brass Threads) in position as per specification, drawing and direction of Engineer in charge. 32 mm dia |
| 193 | Supplying, Installing, Testing & Commissioning at site in position of approved make full way lever operated Forged Brass Ball valve (PN 25) of brass body with forged brass hard chrome plate with all necessary fittings including Male Adapter (Brass Threads) in position as per specification, drawing and direction of Engineer in charge. 40 mm dia. |
| 194 | Supplying, Installing, Testing & Commissioning at site in position of approved make full way lever operated Forged Brass Ball valve (PN 25) of brass body with forged brass hard chrome plate with all necessary fittings including Male Adapter (Brass Threads) in position as per specification, drawing and direction of Engineer in charge.50 mm dia. |
| 195 | Supplying, Installing, Testing & Commissioning at site in position of approved make Butterfly valve (PN-16) wafer type with all acessories required for complete installation including flanges, gaskets, nuts and bolts etc. complete within position as per specification, drawing and direction of Engineer in charge.80 mm dia. |
| 196 | Supplying, Installing, Testing & Commissioning at site, in position, of Automatic Air Release Valves made of Brass of approved make, for water supply pipes. The valve shall function to automatically release trapped air from the pipeline system, thereby ensuring smooth and efficient water flow. The work shall be carried out as per technical specifications, approved drawings, and the direction of theEngineer-in-Charge. 20 mm dia. |
| 197 | Supplying, Installing, Testing & Commissioning at site, in position, of CI Y-type Strainer of approved make, constructed with a drain plug and stainless steel (SS 304) screen, suitable for continuous water flow applications. The strainer shall be complete with all necessary accessories, nuts, bolts, gaskets, and supports, conforming to specifications, and as per the directions of the Engineer-in-Charge.80 mm dia. |
| 198 | Supplying, Installing, Testing & Commissioning at site in position of approved make Brass Float valve (PN 10)with PP float & nipple with brass threaded inser t, brass back nuts, piston and bolts etc. complete in all respect as per specification, drawing and direction of Engineer in charge, 65 mm dia. |
| 199 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore |
| 200 | EXTERNAL SEWARAGE & STORM WATER DRAIN |
| 201 | Supplying, laying, Testing & Commissioning at site in position of approved make PVC pipe of IS 4985 (6 kg/cm2), as per provisions of IS: 1742-1983 (Code of practice for building drainage), joining the pipes with all necessary Fittings including bends, couplers, sockets, connections, reducers, etc. by solvent welding using manuacturer recomended solvent, necessary PCC supports at every interval to maintain the to true lines and gradients through ground/trench, complete in all respects as per the specification drawing and direction of engineer in charge.75 mm dia 6 Kgf / cm2 |
| 202 | Supplying, laying, Testing & Commissioning at site in position of approved make PVC pipe of IS 4985 (6 kg/cm2), as per provisions of IS: 1742-1983 (Code of practice for building drainage), joining the pipes with all necessary Fittings including bends, couplers, sockets, connections, reducers, etc. by solvent welding using manuacturer recomended solvent, necessary PCC supports at every interval to maintain the to true lines and gradients through ground/trench, complete in all respects as per the specification drawing and direction of engineer in charge.110 mm dia 6Kgf /cm2 |
| 203 | Supplying, laying, Testing & Commissioning at site in position of approved make PVC pipe of IS 4985 (6 kg/cm2), as per provisions of IS: 1742-1983 (Code of practice for building drainage), joining the pipes with all necessary Fittings including bends, couplers, sockets, connections, reducers, etc. by solvent welding using manufacturer recommended solvent, necessary PCC supports at every interval to maintain the to true lines and gradients through ground/trench, complete in all respects as per the specification drawing and direction of engineer in charge. 160 mm dia 6 Kgf /cm2 |
| 204 | Providing, laying, and Testing & Commissioning at site uPVC Pipes, Schedule 40, conforming to ASTM D 1785, including all required uPVC fittings as per ASTM D 2466, for external water supply work. The scope includes cutting, jointing using one-step using manufacturer recommended solvent. Pipes to be laid to true line with proper PCC supports at appropriate intervals as required., earth work excavation, backfilling, compacting, and testing the pipeline for leak-proof performance, all complete as per drawings, specifications, and direction of the Engineer-in-Charge. External work- 65 mm nominal outer dia Pipes. |
| 205 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steeel bar conforming to IS:1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) Complete as per design |
| 206 | MISCELLANEOUS |
| 207 | Supplying, Installing & Testing at site in position Fabricated Astm Sch 80 Puddle flange in the overhead / sump water tanks as per the drawings and the requirement of the Project Manager.-80mm(3\") uPVC Astm Sch 80 Puddle flange |
| 208 | Providing and supplying scraper mat of size 1.8m length, including conveyance labour charges etc complete. colour and texture decided by the department official in charge. |
| 209 | Providing and supplying Toilet cleaner 5Ltr (Green cleaning products for housekeeping), including conveyance, labour charges etc complete. |
| 210 | Providing and supplying Floor cleaner 1000ml (Green cleaning products for housekeeping), including conveyance, labour charges etc complete. |
| 211 | PUMPS & ACCESSORIES |
| 212 | Installation, Testing and Commissioning 2 Nos, open well submersible pump set, having CI Impeller and Shafts, SS Casing, Mechanical Seal Each pumps should be capable to deliver 4.5 lps @ 22mtr head, \"\"F\"\" class Insulation, with Wall mounting Microprocessor based common control Panel to operate the pump set with (1Working + 1Standby) Star Delta / DOL starter, having features of automatic pump change over in every Start/Stop, Dry run, Overload, Phase Reversal Protections etc. including level controller with all accessories for Auto Start/ Stop Function, Digital display, Pressure gauge, Float Switches, Auto/Manuel Operation. (For Domestic Water - from Sump Tank to OH Tank) |
| 213 | Installation, Testing and Commissioning 2 Nos, open well submersible pump set, having CI Impeller and Shafts, SS Casing, Mechanical Seal Each pumps should be capable to deliver 2 lps @ 22 head, \"\"F\"\" class Insulation, with Wall mounting Microprocessor based common control Panel to operate the pump set with ( 1Working + 1Standby ) Star Delta / DOL starter, having features of automatic pump change over in every Start/Stop, Dry run, Overload, Phase Reversal Protections etc. including level controller with all accessories for Auto Start/ Stop Function, Digital display, Pressure gauge, Float Switches, Auto/Manuel Operation. (For Flush Water from Sump Tank to OH Tank) |
| 214 | Supply, Installation, Testing and Commissioning 1 No, Submersible Deep well Pump, having SS Impeller and Shafts, CI/SS Casing, Mechanical Seal Each pumps should be capable to deliver 3 lps @ 25 mtr head, \"\"F\"\" class Insulation, with Wall mounting Microprocessor based common control Panel to operate the pump with DOL starter including level controller and all accessories for Auto Start/ Stop Function, Digital display, Pressure gauge, Float Switches, Auto/Manual Operation. (For Water transfer from bore well to Sump Tank) |
| 215 | CIVIL ITEMS FROM PHE |
| 216 | 150x100 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 217 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 218 | Extra for depth for manholesSize 90x80 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5 |
| 219 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:All kinds of soilPipes, cables etc, not exceeding 80 mm dia |
| 220 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia |
| 221 | Supplying and laying interlocking Paver block of size 100 mm or nearest size thickness, with minimum 40% fly ash content by weight of block minimum strength M 40 including providing a layer of 6 mm aggregate for 5 cm thickness, then laying interlock cobbles in lines and levels, material approval as per the directions of the departmental officers at site inclusive of all cost & conveyance charges etc.; complete |
| 222 | WIRING |
| 223 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 224 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 225 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 226 | Wiring for stair case light points with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in and including surface / recessed medium class PVC conduit and all accessories required for complete installation etc , with 1 way modular switch, modular plate, suitable GI box medium class PVC conduit and all accessories required etc and earthing the point with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required and instructed by engineer in charge/consultant. (Note - Staircase light point shall be controlled by a single switch located inside fire control room in ground floor as per latest fire norms)-One light point controlled by one way switch (At ground floor) |
| 227 | Wiring for stair case light points with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in and including surface / recessed medium class PVC conduit and all accessories required for complete installation etc , with 1 way modular switch, modular plate, suitable GI box medium class PVC conduit and all accessories required etc and earthing the point with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required and instructed by engineer in charge/consultant. (Note - Staircase light point shall be controlled by a single switch located inside fire control room in ground floor as per latest fire norms)-Loop wiring for Light point |
| 228 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 229 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 230 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulatedcopper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 231 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 232 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 233 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm |
| 234 | PVC FLEXIBLE CONDUIT - Supply and clamping the following size of corrugated pvc flexible conduit with necessary locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc.as required- 20 mm dia |
| 235 | PVC FLEXIBLE CONDUIT - Supply and clamping the following size of corrugated pvc flexible conduit with necessary locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc.as required- 25 mm dia |
| 236 | PVC FLEXIBLE CONDUIT - Supply and clamping the following size of corrugated pvc flexible conduitwith necessary locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc.as required- 32 mm dia |
| 237 | PVC FLEXIBLE CONDUIT - Supply and clamping the following size of corrugated pvc flexible conduit with necessary locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc.as required- 40 mm dia |
| 238 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 239 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 240 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings). |
| 241 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required. |
| 242 | Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 243 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standardlength(upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc.as required. |
| 244 | DISTRIBUTION BOARDS |
| 245 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door |
| 246 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door |
| 247 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)-4 way (8 + 12), Double door |
| 248 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)-6 way (8 + 18), Double door |
| 249 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)- 8 way (8 + 24), Double door |
| 250 | Supplying and fixing of following ways surface/ recess mounting, Vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)-4 way (8+ 12), Double door |
| 251 | Supplying and fixing of following ways surface/ recess mounting, Vertical type, 415 V, TPN MCCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)-4 way (4+ 12), Double door |
| 252 | Supplying and fixing of following ways surface/ recess mounting, Vertical type, 415 V, TPN MCCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)-6 way (4+ 18), Double door |
| 253 | Supplying and fixing of following ways surface/ recess mounting, Vertical type, 415 V, TPN MCCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)-8 way (4+ 24), Double door |
| 254 | Supplying and fixing of following ways surface/ recess mounting, Vertical type, 415 V, TPN MCCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)-8 way (4+ 24), Double door |
| 255 | Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. |
| 256 | CABLE TRAY |
| 257 | Cable Management System - Supplying and fixing Wall trunking channels of following sizes shall be made of lead free polyvinyl chloride with ROHS compliance non fire propagating material complying to DIN EN 500085-1,2. With a standard length of 2 meter. The system must have a base perforation so as to allow installation in the wall. The WDK 60110 cover must have slide external locking; and with 4 cover clips each in every 2 meter length for a better locking with base trunk. The trunking shall have all accessories like partition, Internal corner cover, External corner cover, T intersection cover, Flat Angle cover, cover clip etc for cable management |
| 258 | Supply and fixing of Perforated Cable tray with horizontal & vertical bends, reducers, Tee\"s, cross over, suitable supports and brackets and other accessories as required confirming to IEC-61537. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461. The trays should be tested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. The perforated tray shall be supplied with the standard length of 3 Mtr. Make: OBO Bettermann or Equivalent- 100 mm width X 60mm Height |
| 259 | Supply and fixing of Perforated Cable tray with horizontal & vertical bends, reducers, Tee\"s, cross over, suitable supports and brackets and other accessories as required confirming to IEC-61537. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461. The trays should be tested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. The perforated tray shall be supplied with the standard length of 3 Mtr. Make: OBO Bettermann or Equivalent- 50 mm width X 60mm Height |
| 260 | Supply and fixing of Perforated Cable tray with horizontal & vertical bends, reducers, Tee\"s, cross over,suitable supports and brackets and other accessories as required confirming to IEC-61537. The Trayshall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461. The trays should betested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflectionshould be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load.The perforated tray shall be supplied with the standard length of 3 Mtr. Make: OBO Bettermann orEquivalent- 150 mm width X 60mm Height |
| 261 | Supply and fixing of Cable Ladder with horizontal & vertical bends, reducers, Tee\"s, Cross over, supports, brackets and other accessories as required confirming to IEC-61537. The Cable Ladder shall be made of1.5mm thick sheet steel up to 600mm & 2.0mm thick up to 1000mm.The cable Ladder shall be galvanized for corrosion protection confirming to ISO 1461. The cable ladder should be tested for safe working load of 225 Kg/ Mtr with a span distance of 2 Mtr the deflection should be within the limits as per standard. The cable ladder shall be supplied in standard length of 3000 mm. The rung size shall be of30x15mmm size suitable for fixing the cable clamps the space between the rungs shall be 300mm. - 200mm Width X 75 mm Height |
| 262 | Supply and fixing of Cable Ladder with horizontal & vertical bends, reducers, Tee\"s, Cross over, supports, brackets and other accessories as required confirming to IEC-61537. The Cable Ladder shall be made of1.5mm thick sheet steel up to 600mm & 2.0mm thick up to 1000mm.The cable Ladder shall be galvanized for corrosion protection confirming to ISO 1461. The cable ladder should be tested for safe working load of 225 Kg/ Mtr with a span distance of 2 Mtr the deflection should be within the limits as per standard. The cable ladder shall be supplied in standard length of 3000 mm. The rung size shall be of30x15mmm size suitable for fixing the cable clamps the space between the rungs shall be 300mm. - 300 mm Width X 75 mm Height |
| 263 | Supply and fixing of Cable Ladder with horizontal & vertical bends, reducers, Tee\"s, Cross over, supports, brackets and other accessories as required confirming to IEC-61537. The Cable Ladder shall be made of1.5mm thick sheet steel up to 600mm & 2.0mm thick up to 1000mm.The cable Ladder shall be galvanized for corrosion protection confirming to ISO 1461. The cable ladder should be tested for safe working load of 225 Kg/ Mtr with a span distance of 2 Mtr the deflection should be within the limits as per standard. The cable ladder shall be supplied in standard length of 3000 mm. The rung size shall be of30x15mmm size suitable for fixing the cable clamps the space between the rungs shall be 300mm. - 750 mm Width X 75 mm Height |
| 264 | MV CABLE SUPPLY, LAYING, & END TERMINATION |
| 265 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended up to date.-3.5C X 120 Sq.mm Al Cable |
| 266 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended up to date.-3.5C X 185 Sq.mm Al Cable |
| 267 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended up to date.-3.5C X 95 Sq.mm Al Cable |
| 268 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended up to date.-3.5C X 70 Sq.mm Al Cable |
| 269 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended up to date.-3.5C X 50 Sq.mm Al Cable |
| 270 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended up to date.-3.5C X 35 Sq.mm Al Cable |
| 271 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended up to date.-4C X 25 Sq.mm Al Cable |
| 272 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductorpower cable confirming to IS 7098 (part 1) amended up to date.-4C X 10 Sq.mm Al Cable |
| 273 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended up to date.-4C X 6 Sq.mm Al Cable |
| 274 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended up to date.-4C X 4 Sq.mm Al Cable |
| 275 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended up to date.- 2C X 10 Sq.mm Al Cable |
| 276 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended up to date.- 2C X 6 Sq.mm Al Cable |
| 277 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended up to date.- 12C X 2.5 Sq.mm Cu Control Cable |
| 278 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade offollowing size direct in ground including excavation, sand cushioning, protective covering andrefilling the trench etc as required.Upto 35 sq. mm |
| 279 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade offollowingsize direct in ground including excavation, sand cushioning, protective covering andrefilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm |
| 280 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade offollowing size direct in ground including excavation, sand cushioning, protective covering andrefilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm |
| 281 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade offollowing size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm |
| 282 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade offollowing size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm |
| 283 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade offollowing size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185 sq. mm |
| 284 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 285 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 286 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade offollowing size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with25/40x3mm MS flat clamp) |
| 287 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 288 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 289 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with25/40x3mm MS flat clamp) |
| 290 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm) |
| 291 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm) |
| 292 | Supplying and making end termination with brass compression gland and aluminium lugs for followingsize of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade asrequired.3 1/2X 95 sq. mm (45mm |
| 293 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) |
| 294 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm) |
| 295 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) |
| 296 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) |
| 297 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 298 | Supplying and making end termination with brass compression gland and aluminium lugs for followingsize of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade asrequired.--4C X 6 Sq.mm Al Cable |
| 299 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.--4C X 4 Sq.mm Al Cable |
| 300 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm) |
| 301 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) |
| 302 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.--12C X 2.5 Sq.mm Cu Control Cable |
| 303 | Supply and laying and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:1554 (Part-I) 1964 of the following sizes in medium duty conduit / cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms amd making good the damages colour washing etc as required. and instructed by engineer at site/consultant.- 1CX6 Sq.mm Copper Flexible Cable |
| 304 | Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.- 1Cx16 Sq.mm Copper Flexible Cable |
| 305 | MCB, RCBO, MCCB, & ISOLATORS |
| 306 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 307 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole |
| 308 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole |
| 309 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. four pole |
| 310 | Supplying and fixing 40 A to 63 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole |
| 311 | Supplying and fixing 40 A to 63 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitablefor inductive load of following poles in the existing MCB DB complete with connections, testing andcommissioning etc as required.Four pole |
| 312 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 313 | RCBO - Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB\"s complete with connections, etc. as required and instructed by engineer in charge/consultant..25A 30mA DP RCBO |
| 314 | RCBO - Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB\"s complete with connections, etc. as required and instructed by engineer in charge/consultant.-16A 30mA FP RCBO |
| 315 | RCBO - Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB\"s complete with connections, etc. as required and instructed by engineer in charge/consultant.-25A 30mA FP RCBO |
| 316 | RCBO - Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB\"s complete with connections, etc. as required and instructed by engineer in charge/consultant.-25A 100mA FP RCBO |
| 317 | RCBO - Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB\"s complete with connections, etc. as required and instructed by engineer in charge/consultant.-32A 30mA FP RCBO |
| 318 | RCBO - Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB\"s complete with connections, etc. as required and instructed by engineer in charge/consultant.-32A 100mA FP RCBO |
| 319 | RCBO - Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB\"s complete with connections, etc. as required and instructed by engineer in charge/consultant.-40A30mA FP RCBO |
| 320 | RCBO - Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB\"s complete with connections, etc. as required and instructed by engineer in charge/consultant.-63A 30mA FP RCBO |
| 321 | MCCB: Supply, fixing, testing and commissioning of following rating, breaking capacity and pole, Thermal Magnetic Release type MCCB in existing Vertical Distribution Board with spreader links, terminal connections and all accessories as required making all necessary connections etc as required and instructed by engineer in charge/consultant- 40 16 kA FP MCCB |
| 322 | MCCB: Supply, fixing, testing and commissioning of following rating, breaking capacity and pole, Thermal Magnetic Release type MCCB in existing Vertical Distribution Board with spreader links, terminal connections and all accessories as required making all necessary connections etc as required and instructed by engineer in charge/consultant- 80 16 kA FP MCCB |
| 323 | Isolator With Enclosure - Supply and fixing of following DP/FP 230V / 415V, isolators in sheet steel powder coated enclosure with door interlock facility on surface confirming to IEC 60947-3 complete with all accessories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.-6A - 40A DP Isolator with enclosure |
| 324 | Isolator With Enclosure - Supply and fixing of following DP/FP 230V / 415V, isolators in sheet steel powder coated enclosure with door interlock facility on surface confirming to IEC 60947-3 complete with all accessories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.-6A - 40A FP Isolator with enclosure |
| 325 | HT CABLE SUPPLY, LAYING, & END TERMINATION |
| 326 | Supply of following 11kV (E) grade XLPE insulated PVC sheathed compact circular armoured aluminium conductor HT power cable, insulation screened with extruded semi conducting compound in combination with copper tape suitable for 11kV earthed system confirming to relevant standard.- 3 C x 300 Sq.mm XLPE Cable |
| 327 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade offollowing size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm |
| 328 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade offollowing size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm |
| 329 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade offollowingsize in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm |
| 330 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit completewith all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductorcable of 11 KV grade as required :300 sq. mm |
| 331 | Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm |
| 332 | HT PART |
| 333 | RING MAIN UNIT - Supply, erection, testing and commissioning of dust and vermin proof, floor mounted, free standing cubicle type, communicable type 11kV Metal Enclosed Outdoor Extensible at one end, Compact Ring Main Unit made out of robotically welded stainless steel tank of IP67 class of protection fully compartmentalized complete with hinged and earthed front doors interlocked with the earth switch. The switch-gear should have the minimum degree of protection (in accordance with IEC 60529).- IP 67 for the tank with high voltage components- IP 54 for the front covers of the mechanism- IP54 for the cable connection covers- Incomer - 11kV, 630A, 350 MVA, Motor operated, Compact, Outdoor, LBS with earth switch - 1 Set Outgoings - 11kV, 630A, 350 MVA, Motor operated, Compact, Outdoor, Non draw out type VCB with O/C & EF self powered Relays + TP, Disconnector, etc. - 1 Sets, CV configuration. Rate shall be inclusive of pre-commissioning test with all accessories and requirements for successful pre- commissioning of unit, as instructed by engineer in charge/consultant and in accordance with all relevant standards and requirements. |
| 334 | TRANSFORMER - Supply, installation, testing & commissioning of 200 kVA 11kV/433V indoor cast resin dry type with Vaccum circuit breaker at primary side, (Copper Double Wound) having a continuous rating for 11kV / 433V 3 phase 50 Hz. Vector group Dyn 11 with tapping +5 % to -10% in steps of 2.5 % by tap links, include separate winding temperature indicator for each phase and core in the Transformer. Transformer should have cable end box on HV side suitable for 3Cx300 sq.mm XLPE cable and LV side suitable for 2RX3.5CX120 sq.mm A2XFY cable, with all accessories, complete as required as per State electricity board, ECBC, IE rules specifications. The transformer shall confirm to IS 2067/77, 11171/1985 with latest amendment etc complete. Foundation for TXR shall be done by other agency. 11 KV Indoor VCB shall be with 11kV, 630A, Seal off bushings, Copper Bus Bar, Support Insulators, connections and inter |
| 335 | Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 336 | DIESEL GENERATORS & EXHAUST SYSTEM |
| 337 | Supply, installation, testing and commissioning of 3phase, 415 V, 0.8 PF 50 Hz radiator cooled DG set of the rating 160 kVA Prime Duty Diesel Generator Set comprising of diesel engine alternator, fuel tank, starting system, battery, battery charger, electronic governor etc with all accessories required for synchronising the DG with another DG\"s. The battery charger of auxiliary DC power supply unit, with dry batteries with connecting leads and terminals with stationary type, high discharge performance, Valve Regulated Lead Acid (VRLA) sealed maintenance free, battery charger including all other accessories like interconnecting cables etc as required for complete installation. The Generator set shall have a integral type acoustic enclosure as per the latest CPCB norms. Diesel engine shall be suitable for continuous operation of generator set and satisfies with EURO-IV+ specifications. |
| 338 | EXHAUST PIPES - Supplying and fixing exhaust gas piping of suitable dia, welded black M.S class \"B\" pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral Wool / Rockwool, 50 mm thick wire mesh & aluminium cladding etc. after applying one coat HR paint as per manufacturer recommendation, as required as per specifications. suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. Horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other accessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for installation. Support to exhaust piping should be done in such a manner that -For 200kVA DG set |
| 339 | LT PANELS |
| 340 | MAIN PANEL- Fabrication, supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV Main panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable.- Incomers-EB Incomer - 320A, 25kA, FP Microprocessor based MCCB - 1 Set.320A, 415V,25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement- Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, Current, Frequency, kW, KVA, kVAr, kWh, kVAh, kVArh, PF, Runhr, Onhr, Interrupts, Phase angle, THD, Neutral current, Max Demand (with RTC),Events (high-low) with time stamp, Individual Harmonics up to 31st, Meter with Ethernet port - 1Sets-RYB phase indicating LED lamps with control fuses and switches - 1 set.-Class B & Class C / Class1 & Class 2 Surge arrestor device with necessary HRC Fuse for back-up protection - 1 Set. - Outgoings-160A, 16kA, TP+NL Microprocessor Based MCCB - 1 Nos., 125A, 16kA, TP+NL Microprocessor Based MCCB - 2 Nos., 80A, 16kA, TP+NL Microprocessor Based MCCB - 1 Nos., LT TOD meters with necessary CT of accuracy class 0.5s with all accessories required for complete with all accessories required for complete installation including its connections and inter connections etc. as per schematic layout. The meter shall be tested and aproval shall be taken from KSEBL - 1 Set , Supply, Installation, Testing and Commissioning of main panel |
| 341 | DG PANEL- Fabrication, supply, erection, testing and commissioning of cubicle type, dust and verminproof, floor mounted, front operated MV Main panel board made out of 14 SWG thick CRCA sheet( 7 tanktreatment) fully compartmentalised complete with hinged and earthed front doors with name plate, dangernotice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steelincluding all components as shown in the schematic drawing. All opening parts of the panel shall besealable.- Incomers- DG Incomer - 320A, 25kA, FP Microprocessor based MCCB with 3 O/C and 1 E/Freleases. Standby low set E/F relay with CT at neutral earthing conductor - 1 Set.- 320A 415V, 25kA bestconductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required.Necessary interlocking arrangement-Multi function digital LED meters with accuracy class 1, withnecessary CT and accessories for measuring Voltage, Current, Frequency, kW, KVA, kVAr, kWh, kVAh,kVArh, PF, Runhr, Onhr, Interrupts, Phase angle, THD, Neutral current, Max Demand (with RTC), Events(high-low) with time stamp, Individual Harmonics up to 31st, Meter with Ethernet port - 1 Set- RYB phaseindicating LED lamps with control fuses and switches - 1 set.- Outgoings- 160A, 16kA, TP+NLMicroprocessor Based MCCB - 1 Nos., 125A, 16kA, TP+NL Microprocessor Based MCCB - 2 Nos., 80A,16kA, TP+NL Microprocessor Based MCCB - 1 Nos.- Supply, Installation, Testing and CommissioningDG PANEL |
| 342 | METERING PANEL 1- Fabrication, supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV Main panel board made out of 16 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Incomer - 80A, FP MCCB Isolator - 1 No.- 80A 433V, 16 kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement- Outgoings - Consumer service each unit consisting of 3 No. 40 A fuse unit, 40A FP MCB,40A ACCL and Three phase energy meter with all accessories required for complete installation including its connections and inter connections etc. as per schematic layout. The meter shall be tested and aproval shall be taken from KSEBL- 1 Set. Consumer service each unit consisting of 3 No. 32A fuse unit, 32A FP MCB, 32A ACCL and Three phase energy meter with all accessories required for complete installation including its connections and inter connections etc. as per schematic layout. The meter shall be tested and aproval shall be taken from KSEBL- 2 Set- Compartment II: DG Back-up- Incomer - 80A, FP MCCB Isolator - 1 No.- Outgoing1: 40A,TP, MCB - 1 No- Outgoing2: 32A,TP, MCB - 2 Nos- Supply,Installation, Testing and Commissioning- METERING PANEL 1 |
| 343 | METERING PANEL 2- Fabrication, supply, erection, testing and commissioning of cubicle type, dust andvermin proof, floor mounted, front operated MV Main panel board made out of 16 SWG thick CRCA sheet(7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate,danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheetsteel including all components as shown in the schematic drawing. All opening parts of the panel shall besealable. Incomer - 125A, FP MCCB Isolator - 1 No.- 125A 433V, 16kA best conductivity extensible AlTPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessaryinterlocking arrangement- Outgoings- Consumer service each unit consisting of 3 No. 63 A fuse unit, 63AFP MCB, 63A ACCL and Three phase energy meter with all accessories required for completeinstallation including its connections and inter connections etc. as per schematic layout. The meter shallbe tested and aproval shall be taken from KSEBL- 1 Set. Consumer service each unit consisting of 3 No.32A fuse unit, 32A FP MCB, 32A ACCL and Three phase energy meter with all accessories required forcomplete installation including its connections and inter connections etc. as per schematic layout. Themeter shall be tested and aproval shall be taken from KSEBL- 3 Set. Compartment II: DG Back-upIncomer - 125A, FP MCCB Isolator - 1 No.- Outgoing1: 63A,TP, MCB - 1 No- Outgoing2: 32A,TP, MCB -3 Nos- Supply, Installation, Testing and Commissioning METERING PANEL 2METERING PANEL 2- Fabrication, supply, erection, testing and commissioning of cubicle type, dust andvermin proof, floor mounted, front operated MV Main panel board made out of 16 SWG thick CRCA sheet(7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate,danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheetsteel including all components as shown in the schematic drawing. All opening parts of the panel shall besealable. Incomer - 125A, FP MCCB Isolator - 1 No.- 125A 433V, 16kA best conductivity extensible AlTPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessaryinterlocking arrangement- Outgoings- Consumer service each unit consisting of 3 No. 63 A fuse unit, 63AFP MCB, 63A ACCL and Three phase energy meter with all accessories required for completeinstallation including its connections and inter connections etc. as per schematic layout. The meter shallbe tested and aproval shall be taken from KSEBL- 1 Set. Consumer service each unit consisting of 3 No.32A fuse unit, 32A FP MCB, 32A ACCL and Three phase energy meter with all accessories required forcomplete installation including its connections and inter connections etc. as per schematic layout. Themeter shall be tested and aproval shall be taken from KSEBL- 3 Set. Compartment II: DG Back-upIncomer - 125A, FP MCCB Isolator - 1 No.- Outgoing1: 63A,TP, MCB - 1 No- Outgoing2: 32A,TP, MCB -3 Nos- Supply, Installation, Testing and Commissioning METERING PANEL 2 |
| 344 | METERING PANEL 3- Fabrication, supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV Main panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable.- Incomer - 125A, FP MCCB Isolator - 1 No.-125A 433V, 16kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement- Outgoings- Consumer service each unit consisting of 3 No. 80 A fuse unit, 80A FP MCB, 80A ACCL and Three phase energy meter with all accessories required for complete installation including its connections and inter connections etc. as per schematic layout. The meter shall be tested and aproval shall be taken from KSEBL- 1 Set.- Consumer service each unit consisting of 3 No.32A fuse unit, 32A FP MCB, 32A ACCL and Three phase energy meter with all accessories required for complete installation including its connections and inter connections etc. as per schematic layout. The meter shall be tested and aproval shall be taken from KSEBL- 2 Set.- Compartment II: DG Back-up- Incomer - 125A, FP MCCB Isolator - 1 No.- Outgoing1: 80A,TP, MCB - 1 No- Outgoing2: 32A,TP, MCB -2 Nos- Supply, Installation, Testing and Commissioning of METERING PANEL 3 |
| 345 | Fabrication, supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floormounted, front operated MV Main panel board made out of 14 SWG thick CRCA sheet (7 tank treatment)fully compartmentalised complete with hinged and earthed front doors with name plate, danger noticeboard, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel includingall components as shown in the schematic drawing. All opening parts of the panel shall be sealable.- EBIncomer - 160A FP MCCB Isolator + 160A FP AC1 Contactor - 1 No.-DB Incomer - 160A FP MCCBIsolator + 160A FP AC1 Contactor - 1 No., 100A 433V, 25kA best conductivity extensible Al TPN bus barwith SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlockingarrangement, Multi function digital LED meters with accuracy class 1, with necessary CT and accessoriesfor measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectablekWh/kVAh - 2 set, RYB phase indicating LED lamps with control fuses and switches - 2 set,Supply,erection, testing & commisioning of AMF for DG set, including necessary SMPS, AUX contactor or Relay,Relay Module, DIN Rail, Selector Switch, Push Button, Terminal, Indication lamp, Legs, End plate,Stopper, 1.5 Ferule, Screw, Neutral link, 2.5 Sqmm wire,1.5Sqmm wire, Cable tie, Tie mount and all otheraccesories and componets as required for complete installation and as instructed by engineer incharge/consultant. - 1 Set, Outgoings- 80A, 16kA, TP+NL Thermal Magnetic Based MCCB, 40A, 16kA,TP+NL Thermal Magnetic Based MCCB, 32A, 16kA, TP+NL Thermal Magnetic Based MCCB, 25A,16kA, TP+NL Thermal Magnetic Based MCCB, 125A Isolator- 1 Nos, Supply, Installation, Testing andCommissioning of UTILITY PANEL |
| 346 | PHE PANEL- Fabrication, supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV Main panel board made out of 16 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable.-Incomer - 40A, 16kA FP Thermal Magnetic Based MCCB - 1 No.-40A, 415V, 16 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required.- Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh - 1 set, RYB phase indicating LED lamps with control fuses and switches - 1 set., Class B+C / Class 1 + 2Surge arrestor device with necessary rating MCB for back-up protection - 1 No.- Outgoings-20A MPCB- 1Nos, 6.3A MPCB- 2 Nos, 4A MPCB- 1 Nos, Supply, Installation, Testing and Commissioning of PHE Panel |
| 347 | LIFT PANEL 1-Fabrication, supply, erection, testing and commissioning of cubicle type, dust and verminproof, floor mounted, front operated MV Main panel board made out of 16 SWG thick CRCA sheet (7 tanktreatment) fully compartmentalised complete with hinged and earthed front doors with name plate, dangernotice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steelincluding all components as shown in the schematic drawing. All opening parts of the panel shall besealable.-Incomer - 63A, FP MCB Isolator - 1No.-63A, 415V, 25 kA best conductivity Al TPN bus bar withSMC supports, heat shrinkable sleeves etc complete as required.-Multi function digital LED meters withaccuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, PowerFactor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh - 1Set, Class B+C / Class 1 + 2 Surgearrestor device with necessary rating MCB for back-up protection - 1 No.- RYB phase indicating LEDlamps with control fuses and switches - 1 set.-Outgoing- 32A, 100mA, FP RCBO - 1 No., 16A, 30mA, DPRCBO - 1 No.- 16A, 415V, 16 kA best conductivity Al DP bus bar with SMC supports, heat shrinkablesleeves etc complete as required - 1 Set- 10A, 10kA, SP MCB - 1 No.-6A, 10kA, SP MCB - 3 Nos.-Supply, Installation, Testing and Commissioning of LIFT PANEL 1 |
| 348 | STREET LIGHT PANEL- Fabrication, supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV Main panel board made out of 16 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable.- Incomer - 25A, FP MCB Isolator - 1No.-25A, 415V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required.RYB phase indicating LED lamps with control fuses and switches - 1 set.- Digital Time Switch with Astronomical function: Digital Time-switch with Astronomical function For switching on/off lights and other electric devices according to the rising/setting of the sun. Daily astronomical- Outgoing- 6 - 32 A, TP MCB - 4 Nos., 6 - 32A, FP Contactor - 3 Nos., Supply, Installation, testing and commissioning of Street light Panel |
| 349 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 350 | LIGHT & FAN FIXTURES |
| 351 | Supply of Linear Surface Mounted LED Batten with a nominal system lumen output of 300 lumens.System wattage should not exceed 20W. The luminaire shall have a rated system lifetime of 50,000burning hours at 70. The luminaire should have a color temperature of 6500K and CRI>80. Driver of theluminaire shall have THD < 20% and PF > 0.95. The heat sink should be made of Extruded thermalpolycarbonate and the luminaire optics shall have a high efficiency PC diffuser. The light fixture includingdriver shall comply to IEC and IS. Similar to Wipro Make Model No: Garnet 20W or equivalent |
| 352 | Supply of 18W 1x1 LED LIGHT, high efficiency with a nominal system lumen output of 1527 lumens. Luminaire wattage should not exceed 18W. Mounting type : Recessed/Surface mounted. The luminaire should have a CRI>80. Driver of the luminaire shall have THD<20% and PF > 0.9. The heat sink should be made of die cast aluminium and the luminaire optics shall have a high efficiency PC diffuser. Aesthetically designed 1X1 LED flat panel of surface mounting which provides soft-light and glare free symmetrical illumination. Similar to Wipro make model No: LD96-221-XXX-65-G1*** or equivalent. |
| 353 | Supply of 36W 2X2 LED SQUARE LIGHT with a nominal system lumen output of 500 lumens and a minimum system efficacy of 95 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a CRI > 80. The luminaire shall meet IP54 rating with THD<10% and PF>0.9. The luminaire housing should made of powder coated CRCA sheet steel with HET Diffuser. The total power consumption should not exceed42W (including driver). LED Shall be Similar to Wipro Make CRCO10R038HP57GL1 or equivalent. |
| 354 | Supply of 36W 2X2 LED SQUARE LIGHT with a nominal system lumen output of minimum 500 lumens. System wattage should not exceed 34W. The luminaire shall have a rated system lifetime of 50,000 burning hours. The luminaire should have a color temperature of 5700K and CRI>80. Driver of the luminaire shall have THD < 10% and PF > 0.95. Housing shall be CRCA powder coated with PMMA diffuser. Driver shall have 85% efficiency. Similar to Wipro Make CRCO10R036HP57TLG2 or Equivalent |
| 355 | Supply of 30W 4X1 LED LIGHT with a nominal system lumen output of minimum 500 lumens. Systemwattage should not exceed 40W. The luminaire shall have a rated system lifetime of 50,000 burninghours. The luminaire should have a color temperature of 5700K and CRI>80. Driver of the luminaire shallhave THD < 10% and PF > 0.95. Housing shall be CRCA powder coated with PMMA diffuser. Driver shallhave 85% efficiency. Similar to Wipro Make CRCO13R038HP57GL1 or Equivalent |
| 356 | Supply of 15W LED DOWNLIGHTER with a nominal system lumen output of minimum 500 lumens. System wattage should not exceed 15W.Mounting type : Recessed/Surface mounted The luminaire shall have a rated system lifetime of 50,000 burning hours. The luminaire should have a color temperature of5700K and CRI>80. Driver of the luminaire shall have THD < 10% and PF > 0.95. Housing shall beCRCA powder coated with PMMA diffuser. Driver shall have 85% efficiency. Similar to Wipro Make LD98-221-024-40-XX** or Equivalent |
| 357 | Supply of Mirror Light, high efficiency with a nominal system lumen output of 760 lumens. Luminaire wattage should not exceed 9W. The luminaire should have a CRI > 80. Driver of the luminaire shall have THD < 10% and PF > 0.9. Slim LED batten in aluminium housing and decorative end caps. Robust driver with wide voltage range 100-240 volts and inbuilt protection. Aesthetically designed mirror LED light fixture of 4000 K, of surface mounting which provides soft-light and glare free symmetrical illumination. Similar to Model number LIGHT LL24-541-XXX-57-CD of Wipro make or equivalent. |
| 358 | Supply of 12W LED DOWNLIGHT, high efficiency with a nominal system lumen output of 760 lumens. Luminaire wattage should not exceed 12W. Mounting type : Recessed/Surface mounted. The luminaire should have a CRI > 80. Driver of the luminaire shall have THD < 10% and PF > 0.9. Slim LED batten in aluminium housing and decorative end caps. Robust driver with wide voltage range 100-240 volts and inbuilt protection. Aesthetically designed mirror LED light fixture of 4000 K, of surface mounting which provides soft-light and glare free symmetrical illumination. Similar to Model number LD98-181-024-40- XX** of Wipro make or equivalent. |
| 359 | Supply of 18W LED LIGHT, high efficiency with a nominal system lumen output of 760 lumens. Luminaire wattage should not exceed 18W. Mounting type : Recessed/Surface mounted. The luminaire should have a CRI > 80. Driver of the luminaire shall have THD < 10% and PF > 0.9. Slim LED batten in aluminium housing and decorative end caps. Robust driver with wide voltage range 100-240 volts and iinbuilt protection. Aesthetically designed mirror LED light fixture of 4000 K, of surface mounting which provides soft-light and glare free symmetrical illumination. Similar to Model number LD95-221-XXX-65-G1*** of Wipro make or equivalent. |
| 360 | Supply of LED Bulk Head Luminaire with max wattage of 10W with system lumens not less than 300Lumes. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. Housing shall be pressure die cast aluminium with IP 65 rating. luminaire should have a color temperature of 5700K and CRI>80. Driver of the luminaire shall have THD<10% and PF >0.9. There should be in-built surge Each protection up to 2 KV. The LED Shall be ANSI Bin C78.377A and IEC62471 with class1 electrical insulation. Similar to Wipro Make LW07- 141-XXX-57-XX or Equivalent. |
| 361 | Supply, fixing, testing and commissioning of 3 M octagonal poles of approved Make having top dia 70 mm, bottom dia 130 mm, Sheet thickness 3 mm, pitch circle dia (PCD) of 200 mm, Base plate dimensions 200mm length x 200mm breadth x 12mm thickness, EN8 grade Foundation bolts of size 4 x16 mm dia, having bolt length of 450 mm. The Octagonal Poles shall be designed to withstand the maximum wind speed as per IS 875. The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The octagonal Poles shall have door of approximate 500 mm length at the elevation of 500 mm from the Base plate.The door shall be vandal resistance and shall be weather proof to ensure safety of inside connections. The door shall be flush with the exterior surface and shall have suitable locking arrangement. There shall also be suitable arrangement for the purpose of earthing. Material Octagonal Poles HT Steel Conforming to grade S355JO. Base Plate Fe 410 conforming to IS 226 / IS2062Foundation Bolts EN.8 grade The poles shall be hot dip galvanised as per IS 2629 / IS 2633 / IS4759 standards with average coating thickness of 85 micron. The galvanizing shall be done in single dipping. The pole shall be with one arm of minimum 0.5 meter long for fixing 20 W LED fixture (Similar to Wipro make : LR02-261-XXX-57-XX LED Street Light). The cost inclusive of all material required for complete installation including light fixture, pole, foundation etc. required as per the specification. |
| 362 | Supplying of ceiling fan of 1200 mm (48 inch) Energy Efficient 5 Star Rated High Speed BLDC CeilingFan with Regulator type, high speed, including the down rod as per the site condition. Similar toAtomberg Ikano or Equivalen |
| 363 | Supply, installation, testing and commissioning of exhaust fan of approved make 250mm (sweep size) BLDC motor Energy Saving Exhaust Fan (Black) as per the specification. Similar to atom Berg efficio or equivalent. |
| 364 | 3 kVA UPS : Supply, installation, testing, and commissioning of 3 kVA UPS standalone Configuration. 1 phase in and out. with indoor (IP21) with surge protection system with 30 Min backup battery @ 1 kva Load (Battery calcualtion shall be submitted.) UPS SMF battery of approved make, Input pf 0.99, Input THDi < 5%, double conversion technology, 230V, 50Hz single phase, output 230V, 50Hz single phase, It shall be 100% generator compatible, with Efficiency > 94 % and output power factor 0.9 (3kVA = 3kW), Eco mode Efficiency 98% and including all accessories etc as required. The acoustic noise at 1m of the system should be<70dB.The system shall comply to IEC /EN 62040-1 (type test of same model will be provided, and relevant IS standard along. The system shall be true online double - conversion DSP based UPS system and also UPS shall be with automatic & manual bypass switch. The system shall have IGBT rectifier and inverter. |
| 365 | LIGHTNING & EARTHING PROTECTION |
| 366 | Supply, installation and testing of 3 meter air terminal with accessories, providing and fixing air terminals as per IEC - 62305 part-3 16mm rod tapered to 10 mm aluminium rod: Meets the technical specification according to DIN EN 50164 - 2 (VDE 0815 part 202). Meets the requirement of VDE0185/305 (IEC62305) 101 VL 4000: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. System consist of Fang Fix with base and clamp on the top air terminal is erected. Fang fix clamp made of cable bracket, lightning tested for 100 KA 10/350 micro sec waveform. 2 nos of 16 KG stone of 365 mm diameter, high level of stability. Quick and easy mounting of interception rod using anchors Concrete, frost-resistant, can be stacked, including all accessories as required for complete installationas instructed by engineer in charge |
| 367 | Supply and installation of 8mm solid aluminium round conductor: For concrete building Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq.mm cross sectional area. Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance, including all accessories as required for complete installation as instructed by engineer in charge. a) Vertical run- Down conductor |
| 368 | Supply and installation of 8mm solid aluminium round conductor: For concrete building Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq.mm cross sectional area. Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degreeCelsius tested. Conductor holder @ 1 meter distance, including all accessories as required for complete installation as instructed by engineer in charge. -b) Horizontal run - Parapet application |
| 369 | Supply and installation of 8mm solid aluminium round conductor: For TERRACE APPLICATION Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq.mm cross sectional area. Stainless steel base with Polyamide Conductor holder top: Adjustable width from 185-260mm. Infinitely adjustable conductor holder. Fast installation using wing screw. Bottom section with 8.5mm diameter slot With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance |
| 370 | Supply and fixing of cross connector / T connector: to route vertical down conductor /mesh formationhexagonal bolts M8*25 with M8 hexagonal nuts and all accessories as required for complete installation |
| 371 | Supply and fixing of expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU. Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Conforms to the requirements according to DIN VDE 0185-305 (IEC 62305) and all accessories as required for complete installation |
| 372 | Supply and Fixing Equipotential bonding rail for Lightning Arrestor applications (Test Joint). Equipotential bonding rail for equipotential bonding according to DIN VDE 0100-410/540 and lightning protection equipotential bonding according to DIN VDE 0185-305. Base plate and cover hood from polystyrene. Colour: Black, UV resistant. Can be used outdoor also. Screw and crossbar made of VA. Capable of carrying lightning current 100KA (10/350). Connection options: 7 x single or multi-core conductors to25mm square or fine core conductors to 16mm square. 1 x round cable Rd 8-10. 1 x flat strip to FL 30 or round cable RD 8-10 including corrosion tapes and all accessories as required for complete installationas instructed by engineer in charge. |
| 373 | Supply and laying hot dip Galvanised Steel Flat having 70 microns zinc 30X3 mm thick from earth electrode directly in ground as required. Hot Dip GI strip, corrosion resistant. Cross sectional area of90mm square According to DIN EN 50164-2 (VDE 0185 part 202) Meets the requirement of VDE0185/305(IEC 62305) Zinc coating: 500 g/m square (70 micron coating) Should be tested and use exclusively for lightning protection earthing system and ring equipotential bonding including crossconnectors and all accessories as required for complete installation as instructed by engineer in charge. |
| 374 | Supply and fixing of PVC trapezoidal 1.5m long ducts including the fastening clamps and all accessoriesas required. |
| 375 | Providing and fixing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. |
| 376 | Providing maintenance free Earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of 3m length , having a diameter of 14.2 mm with copper coating thickness of 250 microns with fault current withstand capability of 13 KA rms value for 1 second and I peak of 31 KA. Universal Clamp (14 25 RTC) made of SS 304 for clamping. Earth enhancing compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. The material should have a resistivity less than 0.2 m. It should be free from hazardous substances The mineral compound is required to have 25 kg/pit of the total composite. Polypropylene & Polyethylene (UFE)Earth electrode inspection chamber with heavy duty cover should be used to cover the Earth Rod. The dimension shall be 250mmx 250mm with a weight bearing capacity of 50KN. |
| 377 | Supply, installation and testing of 1200mmx1200mmx12mm CI plate electrode earth station conforming to IS:3043-1987 / NEC / IEE complete with brick masonry chamber, CI cover, CI frame, GI watering pipe of 50 mm dia with funnel having 20G GI wire mesh etc. The CI cover frame/ chamber shall be of 1000mm x 500mm x 600mm size. CI manhole cover with frame shall be painted with bitumastic paint, identification of earth pit with yellow paint below the chamber cover, mixtures of charcoal & common salt around electrode including digging of pit up to permanent moisture level but not less than 3 metre depth and back filling. ( value of earth resistance should be less than 1 ohm ) |
| 378 | Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling, including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by engineer in charge/consultant.- 25 X 3 Cu strips tinned at the joints |
| 379 | Supply and laying the following sizes of earthing bare copper/strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant.- 25 X 3 Cu strips tinned at the joints |
| 380 | Supply and laying the following sizes of earthing bare copper/strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant.- Copper wire No.10 SWG |
| 381 | Supply and laying the following sizes of earthing bare copper/strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant.- Copper wire No.8 SWG |
| 382 | SAFETY EQUIPMENTS |
| 383 | Sintex Box: Supply,installation, testing and commissioning of SMC Junction boxes,shockproof,rustproof,cable entry from bottom or side, dimension(140x140x95). including all accesories as required for complete installation as instructed by engineer in charge. |
| 384 | Supply and fixing of 4 Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher. pressurized with dry nitrogen gas at 15 bar. Design, construction and testing as per IS 2171-1999 external epoxy powder coating with PO Red Shade No. 538 of IS 5, Supplied with standard accessories. |
| 385 | Supply and providing 2/3 mm thick synthetic type and 1 m wide electrical grade chequered type rubber mat to withstand 3.3 kV dielectric strength conforming to IS 5429/1969. |
| 386 | Supply and providing First Aid Box. |
| 387 | Supply and providing laminated First Aid chart duly framed and placed in a conspicuous location for clearvision. |
| 388 | Supply & fixing Laminated drawings of electrical lay out, schematic drawing etc on good frame work. |
| 389 | Supply and providing MS chequered plate of suitable thickness including cutting, welding, painting etc. as required for cable duct covering etc. |
| 390 | Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steelsheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside andblack on the bottom, inscribed with letters “FIRE” in black and gold or , duly painted over a coat of primer.Cost inclusive of providing 3 Nos of fire bucks and MS stand frame. |
| 391 | Supply of 1 pair 11 KV rubber hand gloves of approved make. |
| 392 | Supply and providing 12 mm thick and 1 m wide electrical grade chequered type rubber mat to withstand11 kV dielectric strength conforming to IS 5429/1969 |
| 393 | 1 FIRE PIPES, VALVES & ACCESSORIES |
| 394 | Hydrant, Sprinkler System and Plant Room : Providing, fixing, pressure testing and commissioning ofAbove Ground Pipe Work with Heavy Duty (Class-C) Mild Steel Pipes, confirming to IS: 3589/1239 Part -I (wherever applicable) and with Heavy Duty Black Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and But Welded Fittings, for pipes above 50mm. dia. confirming to IS:1239 Part - II with all accessories such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, welding, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports as per requirement, providing higher sizes of Sleeves / Opening, wherever required, and closing the gap between the pipes and sleeves/openings as per the direction of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification.-25 mm. |
| 395 | Hydrant, Sprinkler System and Plant Room : Providing, fixing, pressure testing and commissioning ofAbove Ground Pipe Work with Heavy Duty (Class-C) Mild Steel Pipes, confirming to IS: 3589/1239 Part -I (wherever applicable) and with Heavy Duty Black Ductile Iron Screwed Fittings for Pipes up to 50mm.dia. and But Welded Fittings, for pipes above 50mm. dia. confirming to IS:1239 Part - II with allaccessories such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket,bolts, nuts, washers etc. including cutting, threading, welding, joining, fixing in ducts, on walls, ceiling etc.by using suitable and strong enough supports as per requirement, providing higher sizes of Sleeves /Opening, wherever required, and closing the gap between the pipes and sleeves/openings as per thedirection of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approvedpainting system as per technical specification.-32 mm |
| 396 | Hydrant, Sprinkler System and Plant Room : Providing, fixing, pressure testing and commissioning ofAbove Ground Pipe Work with Heavy Duty (Class-C) Mild Steel Pipes, confirming to IS: 3589/1239 Part -I (wherever applicable) and with Heavy Duty Black Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and But Welded Fittings, for pipes above 50mm. dia. confirming to IS:1239 Part - II with all accessories such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, welding, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports as per requirement, providing higher sizes of Sleeves / Opening, wherever required, and closing the gap between the pipes and sleeves/openings as per the direction of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification.-40 mm |
| 397 | Hydrant, Sprinkler System and Plant Room : Providing, fixing, pressure testing and commissioning ofAbove Ground Pipe Work with Heavy Duty (Class-C) Mild Steel Pipes, confirming to IS: 3589/1239 Part -I (wherever applicable) and with Heavy Duty Black Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and But Welded Fittings, for pipes above 50mm. dia. confirming to IS:1239 Part - II with all accessories such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, welding, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports as per requirement, providing higher sizes of Sleeves / Opening, wherever required, and closing the gap between the pipes and sleeves/openings as per the direction of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification.-50 mm |
| 398 | Hydrant, Sprinkler System and Plant Room : Providing, fixing, pressure testing and commissioning ofAbove Ground Pipe Work with Heavy Duty (Class-C) Mild Steel Pipes, confirming to IS: 3589/1239 Part -I (wherever applicable) and with Heavy Duty Black Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and But Welded Fittings, for pipes above 50mm. dia. confirming to IS:1239 Part - II with all accessories such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, welding, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports as per requirement, providing higher sizes of Sleeves / Opening, wherever required, and closing the gap between the pipes and sleeves/openings as per the direction of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification.-65 mm |
| 399 | Hydrant, Sprinkler System and Plant Room : Providing, fixing, pressure testing and commissioning ofAbove Ground Pipe Work with Heavy Duty (Class-C) Mild Steel Pipes, confirming to IS: 3589/1239 Part -I (wherever applicable) and with Heavy Duty Black Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and But Welded Fittings, for pipes above 50mm. dia. confirming to IS:1239 Part - II with all accessories such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, welding, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports as per requirement, providing higher sizes of Sleeves / Opening, wherever required, and closing the gap between the pipes and sleeves/openings as per the direction of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification.-80 mm |
| 400 | Hydrant, Sprinkler System and Plant Room : Providing, fixing, pressure testing and commissioning ofAbove Ground Pipe Work with Heavy Duty (Class-C) Mild Steel Pipes, confirming to IS: 3589/1239 Part -I (wherever applicable) and with Heavy Duty Black Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and But Welded Fittings, for pipes above 50mm. dia. confirming to IS:1239 Part - II with all accessories such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, welding, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports as per requirement, providing higher sizes of Sleeves / Opening, wherever required, and closing the gap between the pipes and sleeves/openings as per the direction of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification.-100 mm |
| 401 | Hydrant, Sprinkler System and Plant Room : Providing, fixing, pressure testing and commissioning ofAbove Ground Pipe Work with Heavy Duty (Class-C) Mild Steel Pipes, confirming to IS: 3589/1239 Part -I (wherever applicable) and with Heavy Duty Black Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and But Welded Fittings, for pipes above 50mm. dia. confirming to IS:1239 Part - II with all accessories such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, welding, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports as per requirement, providing higher sizes of Sleeves / Opening, wherever required, and closing the gap between the pipes and sleeves/openings as per the direction of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification.-150 mm |
| 402 | Hydrant, Sprinkler System and Plant Room : Providing, fixing, pressure testing and commissioning ofAbove Ground Pipe Work with Heavy Duty (Class-C) Mild Steel Pipes, confirming to IS: 3589/1239 Part -I (wherever applicable) and with Heavy Duty Black Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and But Welded Fittings, for pipes above 50mm. dia. confirming to IS:1239 Part - II with all accessories such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, welding, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports as per requirement, providing higher sizes of Sleeves / Opening, wherever required, and closing the gap between the pipes and sleeves/openings as per the direction of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification.-200 mm |
| 403 | Hydrant, Sprinkler System and Plant Room : Providing, fixing, pressure testing and commissioning ofAbove Ground Pipe Work with Heavy Duty (Class-C) Mild Steel Pipes, confirming to IS: 3589/1239 Part -I (wherever applicable) and with Heavy Duty Black Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and But Welded Fittings, for pipes above 50mm. dia. confirming to IS:1239 Part - II with all accessories such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, welding, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports as per requirement, providing higher sizes of Sleeves / Opening, wherever required, and closing the gap between the pipes and sleeves/openings as per the direction of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification.-250 mm |
| 404 | Providing, fixing, pressure testing and commissioning of Underground Fire Protection Pipe Work with Heavy Duty (Class-C) Mild Steel Pipes, confirming to IS: 3589/1239 Part - I (wherever applicable) and with Heavy Duty Black Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and But Welded Fittings, for pipes above 50mm. dia. confirming to IS:1239 Part - II, such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, welding, joining, laying in trenches, providing thrust blocks, providing higher sizes of Protective Sleeve / Pipes and RCC encasement, all as per requirement and to the approval of Engineer - in - Charge/Consultant. The total pipe work shall be protected with approved painting systems and bitumen based flexible wrapping, all as per Technical Specifications-80 mm |
| 405 | Providing, fixing, pressure testing and commissioning of Underground Fire Protection Pipe Work with Heavy Duty (Class-C) Mild Steel Pipes, confirming to IS: 3589/1239 Part - I (wherever applicable) and with Heavy Duty Black Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and But Welded Fittings, for pipes above 50mm. dia. confirming to IS:1239 Part - II, such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, welding, joining, laying in trenches, providing thrust blocks, providing higher sizes of Protective Sleeve / Pipes and RCC encasement, all as per requirement and to the approval of Engineer - in - Charge/Consultant. The total pipe work shall be protected with approved painting systems and bitumen based flexible wrapping, all as per Technical Specifications-100 mm |
| 406 | Providing, fixing, pressure testing and commissioning of Underground Fire Protection Pipe Work with Heavy Duty (Class-C) Mild Steel Pipes, confirming to IS: 3589/1239 Part - I (wherever applicable) and with Heavy Duty Black Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and But Welded Fittings, for pipes above 50mm. dia. confirming to IS:1239 Part - II, such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, welding, joining, laying in trenches, providing thrust blocks, providing higher sizes of Protective Sleeve / Pipes and RCC encasement, all as per requirement and to the approval of Engineer - in - Charge/Consultant. The total pipe work shall be protected with approved painting systems and bitumen basedflexible wrapping, all as per Technical Specifications-150 mm |
| 407 | Providing, fixing, testing and commissioning of Forged Ball Valve, PN-16 or above gunmetal /cast alloy, SS handle including necessary accessories and connections.-25 mm |
| 408 | Providing, fixing, testing and commissioning of Forged Ball Valve, PN-16 or above gunmetal /cast alloy, SS handle including necessary accessories and connections.-50 mm |
| 409 | Providing, fixing, testing and commissioning of Butterfly Valve, PN-16 or above, slim seal, standard leveroperated type confirming to BS:5155 with IS: 13095 Mark, with required companion flanges, nuts, bolts etc. complete.- 80 mm. |
| 410 | Providing, fixing, testing and commissioning of Butterfly Valve, PN-16 or above, slim seal, standard lever operated type confirming to BS:5155 with IS: 13095 Mark, with required companion flanges, nuts, bolts etc. complete.- 100 mm. |
| 411 | Providing, fixing, testing and commissioning of Butterfly Valve, PN-16 or above, slim seal, standard lever operated type confirming to BS:5155 with IS: 13095 Mark, with required companion flanges, nuts, bolts etc. complete.- 150 mm. |
| 412 | Providing, fixing, testing and commissioning of Butterfly Valve, PN-16 or above, slim seal, standard lever operated type confirming to BS:5155 with IS: 13095 Mark, with required companion flanges, nuts, bolts etc. complete.- 250 mm. |
| 413 | Providing, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16 or above, Vertical / Horizontal Type , as per final requirement, conforming to IS: 13095 with nuts, bolts etc. complete.- 80 mm |
| 414 | Providing, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16 or above, Vertical / Horizontal Type , as per final requirement, conforming to IS: 13095 with nuts, bolts etc. complete.- 150 mm |
| 415 | Supply, installation, testing and commissioning of following Heavy Duty Neoprene Expansion Joints /FlexibleConnectors, PN:16, with Spilt Retainer Rings and Control Units, drilled to BS 10 Table E includingall other necessary fixing accessories -80mm |
| 416 | Supply, installation, testing and commissioning of following Heavy Duty Neoprene Expansion Joints / FlexibleConnectors, PN:16, with Spilt Retainer Rings and Control Units, drilled to BS 10 Table E including all other necessary fixing accessories.- 150 mm. |
| 417 | Supply, installation, testing and commissioning of Hydraulically Operated Fire Sprinkler Alarm Valve (Installation Control Valve), Grooved End, UL Listed / FM approved, complete with Constant Pressure Trim Assembly, Water Motor Gong, control valves, pressure switch, pressure gauges etc. including all necessary fixing accessories.-150 mm size |
| 418 | Supply, installation, testing and commissioning of Air Release Valve Gunmetal, conforming to IS903:1993, having rubber ball with sealing seat and with 25mm. BSP threaded male inlet, including necessary accessories and connections. |
| 419 | Providing and fixing C.I. Gate Valve with Non Rising Stem & Cap Top, PN-16, confirming to IS: 14846 with ISI Mark and with required companion flanges, rubber insertions, bolts, nuts, Washers etc. complete. The Price shall be inclusive of ‘Fabricated Key\" for Operation from Ground Level, as per Technical Specifications.-150 mm |
| 420 | Providing and fixing sight glass assembly of brass body and brass ball with chrome plated Test & drain valave, steel handle, PN16 or above, UL Listed & FM Approved. Test and drain valve shall be with compact 3 position ball valves with drain orifice having K-factor 5.6 and a sight glass. 3 positions consist of OFF, TEST and DRAIN. Test and drain valves shall be provided for test as well as express drain functions in wet sprinkler systems with grooved end connection ends. The Test and Drain Valve shall be in Brass ASTM B584 material of construction. These have integral tamper resistant sight glass. |
| 421 | Supply, installation, testing and commissioning of following 4\" dia. Bourdon Type Pressure Gauge, withISI Mark or of equivalent International Standards.-Weather / Water Proof Type Pressure Gauge with shut off cock and connection Pipe |
| 422 | Supply, installation, testing and commissioning of following 4\" dia. Bourdon Type Pressure Gauge, with ISI Mark or of equivalent International Standards.-Standard Type for indoor use Pressure Gauge with shut off cock and connection Pipe |
| 423 | FIRE HOSE REEL & HYDRANT SYSTEMS |
| 424 | Supply, installation, testing and commissioning of Fire Protection Equipment shall be inclusive cost of materials and necessary fixing accessories such as isolation valve, braided hose, neoprene gasket etc. and fixing accessories such as fabricated M.S. Supports, bolt, nut, washer, circle. Teflon tape etc, all as per requirement. All other work such as extension of pipe work, accessories such as threaded nipple, matching flanges etc. shall be counted as an integral part of fabrication of fire line work. Supply, installation, testing and commissioning of Manual Swing Type Fire Hose Reel Complete Set with heavy duty drum / reel, 19 mm. dia, 30 Meter long 2-ply polyester yarn braided / rubber braided pressure hose, Red Coloured, heavy duty nylon on/off jet/spray nozzle, 22 mm. isolating valve and all other necessary fixing accessories including Fabrication and Erection of M.S. Support, as per requirement, for Fixing the Fire Hose Reel Set. |
| 425 | Supply, installation, testing and commissioning of Fire Hydrant Valve, bearing to ISI:5290 Type-A mark, Stainless Steel-304 body with 63 mm. oblique instantaneous single outlet, 75 mm. N.B. flanged inlet, Stainless Steel - 304 spindle, complete with PVC blank cap, G.I. chain etc. |
| 426 | Supply, installation, testing and commissioning of Fire Brigade Inlet Breeching, C.I. body, having 3 WayGunmetal, 63mm. male instantaneous inlet, conforming to IS: 903, with non return valves, 25mm. drainvalve, flanged outlet, 3 Nos. of rubber blank caps and G.I. chains |
| 427 | Supply, installation, testing and commissioning of Fire Hose, RRL hose jacketed with circular woven synthetic fiber.conforming to IS: 636:88, with Working Pressure 14 Kg/Cm2, Proof Pressure 22 Kg / Cm2 and Burst Pressure 38 Kg / Cm2. The Fire Hose shall be with IS: 636 Type-A marking and 63mm. dia.,15 Meter long with pair of 63mm. male and female instantaneous couplings, Stainless steel - 304, havingIS: 903 mark and duly S. S. wire wounded. The hose shall be rolled and hung to suitable M. S. support in the Fire Hose Cabinet. |
| 428 | Supply, installation, testing and commissioning of Branch Pipe, Stainless Steel-304, short type, with63mm. male instantaneous inlet, male threaded outlet, fitted with 16mm. bore nozzle, having IS: 903 mark. |
| 429 | Supply and fix at site in position MS Fire Hose Cabinet made out of 16 gauge MS Sheet, wall / pole mounting type, to accommodate two 15m length of delivery hose and branch pipe, acrylic fronted double door, with lock, 2 keys and a break glass recess for keys, painted Fire Red. The words \"FIRE HOSE\" to be painted on the box. The price shall be inclusive of fixing with all accessories and as per requirement. |
| 430 | Supply and fix at site in position Weather Proof MS Fire Hose Cabinet made out of 16 gauge MS Sheet, wall / pole mounting type, to accommodate two 15m length of delivery hose and branch pipe, acrylic fronted double door, with lock, 2 keys and a break glass recess for keys, painted Fire Red. The words \"FIRE HOSE\" to be painted on the box. The price shall be inclusive of fixing with all accessories and as per requirement. |
| 431 | AUTOMATIC FIRE SPRINKLER SYSTEM |
| 432 | Providing, fixing, testing and commissioning of Standard Coverage, Quick Response Automatic Fire Sprinkler, K- Factor: 5.6 (80 Metric) with all accessories necessary for complete installation. The Fire Sprinklers shall be UL listed / FM Approved- Upright Type, 68 Degree C Rating |
| 433 | Providing, fixing, testing and commissioning of Standard Coverage, Quick Response Automatic Fire Sprinkler, K- Factor: 5.6 (80 Metric) with all accessories necessary for complete installation. The Fire Sprinklers shall be UL listed / FM Approved- Pendant Type, 68 Degree C Rating. |
| 434 | Providing & Fixing 2 Piece Chrome Plated Friction Fit recessed escutcheon for pendant sprinklers, as per requirement. |
| 435 | Providing, Fixing, Testing and Commission Flexible Sprinkler Hose; UL Listed & FM Approved, 25mm. (1\") BSP Male Inlet, 15mm. (1/2\") NPT Female Outlet, Braided, Working Pressure 13.8 Bar, 1 meter long, and with all connecting systems and accessories required for complete installation. |
| 436 | Providing, Fixing, testing and commissioning of Flow Switch, Vane type, IP 65 Protection with 20 Bar Working Pressure Protection with all necessary accessories, for monitoring Fire Sprinkler System. The control cabling from flow switches to Fire Sprinkler Annunciating Panel shall be measured separately. |
| 437 | FIRE PUMPS AND ACCESSORIES |
| 438 | MAIN PUMP - Supply, installation, testing and commissioning of Horizontal long coupled End Suction Fire Hydrant Pump Set: Electrical Driven, Capacity: 2280 LPM at 62 Meter Head, conforming to IS 1520, with Bronze Impeller, S. S. Shaft, Mechanical Seal, High Efficient IE-3 rated, Squirrel Cage Induction Electric Motor, Suitable HP, 3Ph, 50 Hz, 2900/3000 RPM, TEFC, complete with necessary concrete foundation duly plastered, MS fabricated common base plate with foundation bolts, compound gauge, water re-circulation arrangement, pressure relief valve, anti-vibration mounts, as per requirement and nececssary earthing of Electric Motors, etc. all as per the Technical Specifications, Prevailing Rules, Standards, Requirement and Site Conditions. |
| 439 | JOCKEY PUMP - Supply, installation, testing and commissioning of Jockey Pump: Electrical Driven,Capacity: 180 LPM at 67 Mtrs. Head, Vertical Multi Stage Inline Pump with S.S Impeller, MechanicalSeal, and with High Efficient IE-3 Rated Squirrel Gauge Induction Motor, Suitable HP, 3Ph, 50 Hz,2900/3000 RPM, TEFC, complete with necessary concrete foundation duly plastered, MS fabricatedcommon base plate with foundation bolts, compound gauge, water re-circulation arrangement, pressurerelief valve, anti-vibration mounts, as per requirement and necessary earthing of Electric Motors, etc. allas per the Technical Specifications, Prevailing Rules, Standards, Requirement and Site Conditions |
| 440 | DIESEL PUMP - Supply, installation, testing and commissioning of Stand By / Back Up Fire Pump, Horizontal long coupled, End Suction Pump, Engine Driven, suitable for Automatic operation and consisting of the following and complete in all respect as required; Capacity: 2280 LPM at 62 Meter Head conforming to IS 1520, with Bronze Impeller, S. S. Shaft, Mechanical Seal, coupled to High Efficient Radiator Cooled Diesel Engine, Suitable HP, 2150/2920 RPM, and with Control Panel with Auto Starting Facility, by activation of concerned Pressure Switch and thro. 12V/24 V Electric Starter, Battery of adequate rating and with Battery Charger, Battery Leads, Diesel Tank for 6 hrs operation, exhaust pipe extended up to 1 mtr outside pump house, duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per specification, complete with necessary civil foundation, foundation bolts, compound gauge, water re-circulation arrangement, pressure relief valve, and all other necessary fixing accessories, all as per Technical Specifications. |
| 441 | Supply, erection, commissioning of additional length of Exhaust Pipes with long radius bend from silencer with necessary clamps, fixtures, civil works andthermal insulation with 50 mm thick glass wool and with1.0 mm thick aluminium sheet cladding of following adequate size including suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. The horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for istallation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbocharger. Exhaust pipeheight shall be 3m more than the top of any adjacent building withing 10m radius of the exhaust. |
| 442 | MOTOR CONTROL PANEL - Fabrication, supply, erection, testing and commissioning of cubicle type,dust and vermin proof, floor mounted, front operated Common Control Panels for Main Fire Pumps &Jockey Pumps, made out of 16 SWG thick CRCA sheet fully compartmentalised complete with hingedand earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removablegland plates (top entry) made out of 3mm thick sheet steel including all components as shown in theschematic drawing. All opening parts of the panel shall be sealable. The panel shall be IP: 54 protection,complete with Main Isolator, Bus Bar Chamber, Volt Meter, Ammeter, Individual Star- Dealt Startersfor Main & Sprinkler Pumps, DOL Starter for Jockey Pumps, Contactors, Auxiliary Contacts, Timers forautomatic operation and to avoid freequent re-starts, Indicating Lamps, Fuses, Auto / Manual SelectorSwitches for all Fire Pumps, Manual On / Off Buttons for Jockey Pump & Manual On Buttons for MainPumps, all internal wiring etc. The price for Control Panel shall be inclusive of, Control Cabling, inSteel Conduits, for automatic starting of Main Pumps & Automatic start and stop for Jockey Pump andEarthing of the Panel, all as per Technical Specifications, Schematic Drawing, Prevailing Rules,Standards, Requirement and Site Conditions. The Panel shall be to the approval of Kerala StateElectrical Inspectorate.- Incomer - 250A, FP, MCCB Isolator - 1No.-250A, 415V, 25 kA best conductivityAl TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required.-Multi functiondigital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage,current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh, Class B +C / Class 1 + 2 Surge arrestor device with necessary MCCB for protection of same - 1 Set.RYB phaseindicating LED lamps with control fuses and switches - 1 set.Outgoing- 125 A, TP+NL, MCCB Isolator +Star delta starter with all accessories Without overload relays / protection - 1 Set. 32A, TP+NL, MCCBIsolator + DOL Starter with all accessories with overload realy and single phase preventor - 1 Set., 25A,DP Isolator for diesel engine battery charger, Supply, Installation, Testing & Commissioning |
| 443 | Supply, installation, testing and commissioning of Pressure Switches with pressure rating suitable for above Fire Pumps, with a differential of 0.2 to 1.6 Bar, as per Technical Specifications. |
| 444 | Supply, installation, testing and commissioning of Diaphragm Pressure Vessel, 112 Ltrs Capacity, 15 ar Working Pressure at a maximum flow rate of 2850 LPM. The vessel shall be with replaceable interior air cell, metallic outer shell, base, air release valve etc, all as per Technical Specifications. |
| 445 | INTELLIGENT ADDRESSABLE FIRE ALARM SYSTEM |
| 446 | Supply, installation, testing and commissioning of 12 Zone conventional Fire Alarm panel with 30mminbattery back-up with necessary indications, solid state circuitry with visual front and alarm display. Thepanel shall be designed that the audio alarm activation and silencing switches. The panel shall beprovided with repeated system for both audio as Set well as visual. The panel should have facility toattach standby power system using batteries with all accessories required for completeinstallation.Supply, install, test and commission of microprocessor based, Intelligent Addressable, truePeer-to-Peer networkable, Fire Alarm Control Panel (MCP) as per the technical specification and tohaving a Visual Touch Screen Display Unit with Battery Back up for 24 hours for normal operation and 1hours on alarm condition. The control panel, battery charger etc, shall be UL listed approved. The panelshall networked together and capable of networking with other compatible panels and compactible forBMS connectivity (Backnet/Modbus). The Panel shall have sufficient Loop Capacity to accomodate thedevices and detectors as per the final design for this project with 10 % spare capacity in each loop. Thepanel shall be expandable for future upgradation, all as per Technical Specifications. |
| 447 | Supplying, installation, testing & commissioning of intelligent analog addressable Photothermal detector complete with mounting base complete as required |
| 448 | Supplying, installation, testing & commissioning of intelligent analog addressable Photothermal detector complete with mounting base complete as required - Above ceiling |
| 449 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 450 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required |
| 451 | Providing, fixing, testing and commission Intelligent Addressable Input / Monitor Module, as per specification for Interface with Flow Switches, Fire Pumps, Supervisory Switches, Alarm Valve, Water Tank Level etc.- |
| 452 | Supplying, installation, testing & commissioning of addressable fire control module complete as required |
| 453 | Supplying, installation, testing & commissioning of fault isolator complete with base as required. |
| 454 | Supplying, installing, testing and commissioning approved make Addressable Power Supply Unit (PSU)of 24V DC for Notification Appliances. The PSU shall be UL Listed, supervised by Fire Panel & of thesame make as Fire Alarm System |
| 455 | Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required |
| 456 | FIRE EXTINGUISHERS |
| 457 | Providing, fixing, commission and install in position following Portable Fire Extinguisher as per BIS 2190 and BIS: 15683:2006 and with relevant ISI Stamping/Marking.- ABC Dry Powder, Propellant - Dry Nitrogen, Store Pressure Type - 2 Kg. |
| 458 | Providing, fixing, commission and install in position following Portable Fire Extinguisher as per BIS 2190 and BIS: 15683:2006 and with relevant ISI Stamping/Marking.-ABC Dry Powder, Propellant - Dry Nitrogen, Store Pressure Type - 4 Kg. |
| 459 | Providing, fixing, commission and install in position following Portable Fire Extinguisher as per BIS 2190 and BIS: 15683:2006 and with relevant ISI Stamping/Marking.- CO2 - 4.5Kg. |
| 460 | Providing, fixing, commission and install in position following Portable Fire Extinguisher as per BIS 2190 and BIS: 15683:2006 and with relevant ISI Stamping/Marking.- Clean Agent HCFC 123 - 4.0 Kg. |
| 461 | Providing, fixing, commission and install in position following Portable Fire Extinguisher as per BIS 2190 and BIS: 15683:2006 and with relevant ISI Stamping/Marking.- Fire Bucket including Fabricated M. S. |
| 462 | TALK BACK SYSTEM |
| 463 | Supply, installation, testing & commisioning of micro process based automatic talk back system with controller of 10 Zone, 500 W amplifier, Goose neck type microphone, complete with floor to floor announcing and talk back facilities with the following features and made functional: (a) Feather type key pads to select the zones. (b) Moulded plastic attractive enclosure. (c) Backlight Liquid Crystal Display (LCD) (d) User friendly interactive display. (e) Announcement selector - PH Switch. (f) Listen selector switch. (g) All Call switch to select all zones simultaneously for announcement (h) Zones Call Display On the LCD With Audio Alarm. Controller Unit with 500 W amplifier, Goose neck type microphone and with the following features: (i) Built in Power supply. (ii) Zone Selector switching Circuit (iii)Terminal blocks to terminate zones wires, amplifier wires etc., (iv) Zone Call processing Circuit etc and made functional. Panel to be installed in the Fire Control Room. |
| 464 | Supply, installation, testing and commisioning of Public Address speaker with talk back facility 6 Watts with L M T and call switch, made out of powder coated CRCA sheet, wall mounting type and to be installed at a height of not less than Set. 150 CM from the finished floor levels, suitable for concealed mounting. |
| 465 | Providing, fixing / laying, test and commission 2Core x 1.5 mm2 FRLS Armored Cables with Red Colour / Finish, as per Technical Specifications |
| 466 | SIGNAGES |
| 467 | Fire Exit Light - Laser type, with High Glow LED Light, size: 12” x 6” or nearby, Ceiling Mounting type with hanging clamps, on/off switch, Red / Green Colour option, power consumption: 8 Watt or less with all accessories required for Set complete installation as directed by the engineer inc charge. Power supply shaould be provided with UPS back-up. |
| 468 | Supply and install in position following Sign Boards made out of 3mm thick \"Opaque\" PVC foam boardwith computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirrorfasteners with all accessories required for complete installation as directed by the Engieer in charge.Signage Printed \"IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE\" of 1.25cm.height letters in red with white back ground. The size of the board shall be 25 x 30 Cm. and shall be fixedat the height of 2Mts. from Nos. finished floor near Manual Pull Stations. |
| 469 | Supply and install in position following Sign Boards made out of 3mm thick \"Opaque\" PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners with all accessories require Floor Identification Signage ( ie, GROUND FLOOR, FIRST FLOOR, etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 5 Cm. with contrasting colour from back ground. Size shall Nos. be 15cm x 30cm. |
| 470 | Supply and install in position following Sign Boards made out of 3mm thick \"Opaque\" PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners with all accessories required for complete installation as directed by the Engineer in charge. Floor Identification Signage (MAIN STAIRCASE, FIRE STAIRCASE, FIRE ASSEMBLY POINT, PUMP ROOM, FIRE CONTROL ROOM, ELECTRICAL ROOM, FIRE LIFT, PASSENGER LIFT Etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 5 Cm. with contrasting colour from back ground. Size shall be 15cm x 30cm. |
| 471 | Supply and install in position following Sign Boards made out of 3mm thick \"Opaque\" PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners with all accessories required for complete installation as directed by the Engineer in charge. Supply and install in position the Signage \"FIRE ORDER\" it should contain the matter specified in the technical details on 3mm thick \"Opaque\" PVC foam board of computerized cut, PVC non-reflective self adhesive vinyl painted foam board of 2\" x 3\". |
| 472 | MISCELLANEOUS ITEMS |
| 473 | Fabrication, supply, installation at site Heavy Duty Galvanized Mild Steel Puddle Flange, Fabricated fromHeavy Grade M. S. Pipe, confirming to IS: 1239/ 3589, with PN:20 Drilled M.S. Flange(s), as per TableBS-10 and M.S. Plate, all as per tender drawings and technical specifications, provided. After totalfabrication, the puddle flange should be hot dipped galvanized to IS: 4759 and further protected withEpoxy Coating to the approval of the Engineer - in - charge and Consultant.- 100 mm dia |
| 474 | Fabrication, supply, installation at site Heavy Duty Galvanized Mild Steel Puddle Flange, Fabricated from Heavy Grade M. S. Pipe, confirming to IS: 1239/ 3589, with PN:20 Drilled M.S. Flange(s), as per Table BS-10 and M.S. Plate, all as per tender drawings and technical specifications, provided. After total fabrication, the puddle flange should be hot dipped galvanized to IS: 4759 and further protected with Epoxy Coating to the approval of the Engineer - in - charge and Consultant.- 150 mm dia |
| 475 | Fabrication, supply, installation at site Heavy Duty Galvanized Mild Steel Puddle Flange, Fabricated from Heavy Grade M. S. Pipe, confirming to IS: 1239/ 3589, with PN:20 Drilled M.S. Flange(s), as per Table BS-10 and M.S. Plate, all as per tender drawings and technical specifications, provided. After total fabrication, the puddle flange should be hot dipped galvanized to IS: 4759 and further protected with Epoxy Coating to the approval of the Engineer - in - charge and Consultant.- 250 mm dia |
| 476 | FIRE SEALANT for all Shafts - Supply and Fixing of load bearing Fire stop mortar system with minimum2 hours fire rating when tested in accordance with UL 1479 standards, for openings in floors or slabs after passing service lines. The mortar shall be a light weight cementitious product and shall carry test certificate in accordance with IEC 60068-2- 57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall be age tested as per Dafstb and DIBT standards. The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96 and shall have a VOC content of approx. <1 g/l as per LEED 2009. Firestop installation should be done by trained applicators (HAFSC) and in accordance with manufacturer\"s guidelines by providing 10mm dia rebars at 200mm c/c both ways with chemical anchoring along the length and breadth of the shaft and provide 2 layers of chicken mesh etc. The mortar shall be applied with a minimum thickness of 65 mm & having load bearing capacity of 200kg/sqm. Proper engineering judgement needs to be submitted through the manufacturer. Complete installation report through Software CFS DM shall also be submitted for inspection purpose. |
| 477 | EXTERNAL (CIVIL) WORK |
| 478 | Constructing masonry Valve Chamber in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice / gate valve, including all supports for fixing valve, with Heavy Duty C.I. cover and frame, i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design-Internal Size: 60 x 60 x 75cm, deep |
| 479 | Extra Low Voltage System- IP SURVEILLANCE SYSTEM |
| 480 | Fixed Dome Camera-Supply, Installation, testing and commissioning of IPbased3.6mmfixedlens,4MPresolution,H.264/H.265,1/2.8\"ProgressiveScanCMOSDay/Night,IRdomePOEenabledcamera,20to30metersIRrange,120dBdigitalWDR with all connectors and necessary accessories for mounting in false ceiling/wall as required for complete installation as directed by Engineer in charge. PoE (Power over Ethernet) |
| 481 | FixedDomeCamera-Supply,Installation,testingandcommissioningofIPbased2.8mmfixedlens,4MPresolution,H.264/H.265,1/2.8\"ProgressiveScanCMOSDay/Night,IRdomePOEenabledcamera,20to30metersIRrange,120dBdigitalWDRwithallconnectorsandnecessaryaccessoriesformountinginfalseceiling/wallasrequiredforcompleteinstallationasdirectedbyEngineer in charge. PoE (Power over Ethernet) |
| 482 | Bullet Camera-Supply, Installation, testing and commissioning of Varifocal Bullet Camera with 4MP, H.264/H.265,built-in IRLED,2.8/3.6mm to 9/12mm,20 to 30 meters IR range, IP66 with all connectors and necessary accessories for mounting in false ceiling/ True Ceiling / wall as required for complete installation as directed by Engineer in charge. PoE (Power over Ethernet) |
| 483 | Net work Video Recorder with Storage: Supply, installation, testing and commissioning of Following Channel Network Video Recorder with Recording Storage space server for 30days, Supports corresponding channels 720P resolution video recording at real time, NVRONVIF supporting, Recording resolution of 4MP or above, should support dual video HDMI output, H.265,H.264 at real time. Video storage expansion for recording, with all accessories required for complete installation and directed by engineer in charge (Consider the sufficient HDDs for 720 p @ 20 FPS for 30 days continues recording for all channels).Storage calculation details shall be submitted. 16 channels 720 P resolution |
| 484 | Net work Video Recorder with Storage: Supply, installation, testing and commissioning of Following Channel Network Video Recorder with Recording Storage space server for 30days, Supports corresponding channels 720P resolution video recording at real time, NVRONVIF supporting, Recording resolution of 4MP or above, should support dual video HDMI output, H.265,H.264 at real time. Video storage expansion for recording, with all accessories required for complete installation and directed by engineer in charge (Consider the sufficient HDDs for 720 p @ 20 FPS for 30 days continues recording for all channels).Storage calculation details shall be submitted. 32 channels 720 P resolution |
| 485 | LED Display - Supply, installation, testing and commissioning of 43 inch full HD LED display forvideo wall arrangement for 24 x 7 Setup including necessary connection, HDMI cable, rating trayetc. as required for complete installation with all accessories as required and directed by engineerin charge. |
| 486 | Supply, installation, testing and commissioning of Client Monitoring System with Intel I7 latestgeneration processror or above, 16 GB ram and Sufficient TB HDD as per calcultion with softwarefor CCTV integration. |
| 487 | Extra Low Voltage System- PUBLIC ADDRESSING SYSTEM |
| 488 | Ceiling Mounted Speaker - Supply, fixing, testing and commissioning of ceiling mount Metal GrilleSpeakers with inbuilt line matching transformer with power 6W with all accessories required forcomplete instllation as required. |
| 489 | Box Speaker-Supply, fixing, testing and commissioning of wall mounted box Speakers within built line matching transformer with power 12W with a volume controller to adjust the volume individually as per the requirement with all accessories including wall mounting kit required for complete installation. The volume controller shall be fixed separately as per the site condition for individual control. Cost inclusive of necessary inter connection including conduit, connection wire etc. |
| 490 | Mixing Amplifier - Supply, fixing, testing and commissioning of 240 Watts Mixer Amplifier with necessary jacks and cable for connections and interconnection with all accessories required for installation as required. |
| 491 | Power Amplifier-Supply, fixing, testing and commissioning of following Power Amplifier with necessary jacks and cable for connections and inter connection with all accessories required for installation as required. Power Amplifier of 480 Watts |
| 492 | Controller - Supply, fixing, testing and commissioning of Master zone controller with routing zone capcity of additional 6 zones with all acessories and necessary connections including necessary cables and jacks as required for complete installation. The work also include integration with Fire Alarm ystem (FAS) including to play the pre-recorded message in case of fire and evacuation. |
| 493 | Call Stations - Supply, fixing, testing and commissioning of 6 Zone Calling Station with mic as per the drawing as required for complete installation. |
| 494 | Audio/Video player - Supply, installation, testing & commissioning of Audio/Video player with USB option with all accessories like jacks and codes for complete installation as required as directed by the Engineer in charge. |
| 495 | Speaker Cable - Supplying and drawing of 2 Core, Twin Twisted, ATC tinned copper, overall sheathed, Armoured Speaker cable, 16 AWG for speakers through surface / Tray with all acessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation. |
| 496 | Extra Low Voltage System- STRUCTURED CABLING COMPONENTS |
| 497 | Information Outlet RJ 45 for Data - Supply, fixing, fluke testing and commissioning of CAT6 Information Outlets (Key stone) with Shuttered Faceplate, Single port, white, jack, suitable PVC / GI Modular Box etc. including necessary connections with all accessories required for complete installation as directed by the Engineer in charge. |
| 498 | Information Outlet RJ 45 for Wi-Fi / CCTV - Supply, fixing, fluke testing and commissioning of CAT6 Information Outlets (Key stone) with Shuttered Faceplate, Single port, white, jack, suitable PVC / GI Modular Box etc. including necessary connections with all accessories required for complete installation as directed by the Engineer in charge. |
| 499 | Information Outlet RJ 45 for Voice - Supply, fixing, fluke testing and commissioning of CAT6 Information Outlets (Key stone) with Shuttered Faceplate, Single port, white, jack, suitable PVC / GI Modular Box etc. including necessary connections with all accessories required for complete installation as directed by the Engineer in charge. |
| 500 | Information Outlet Coaxial - Supply, fixing, testing and commissioning of Coaxial Information Outlets (Key stone) with shuttered Faceplate, single port, white, jack, suitable PVC / GI Modular Box etc. including necessary connections with all accessories required for complete installation as directed by the Engineer in charge. |
| 501 | Ceiling Connector Assembly - Supply, fixing, testing and commissioning of reusable ceiling connector assembly for connecting CAT 5e / 6 / 6A directly to the wireless access points along with pigtail Including necessary connections with all accessories required for complete installation as directed by the Engineer in charge |
| 502 | CAT6 Cable - Supplying and drawing of CAT 6 U/UTP 23 AWG LSZH As per EIA/ TIA Standards,surface/ recessed medium class PVC conduit through wall / tray with all acessories as required for complete installation and as instructed by engineer in charge / consultant and making good alldamages made for installation. |
| 503 | Coaxial Cable - Supplying and drawing of coaxial cable in surface / recessed medium class FRS PVCconduit through wall/tray with all acessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation. |
| 504 | krone Box - Supply, erection, testing and commissioning of following pair krone with Box including mounting frame, enclosure of ISI grade with lockable front cover with all accessories required for for complete installation in wall as directed by the Engineer in charge.- 10 Pair IDF Krone |
| 505 | Patch Cable - Supply, Installation, Testing & Commissioning of CAT6 Patch Cord LSZH with Moulded boots Over-moulded boot at each end provide strain relief and maintains minimum bend radius of the cable - 2 Meter with Tender specifications and all the required accessories to complete the system |
| 506 | Patch Cable - Supply, Installation, Testing & Commissioning of CAT6 Patch Cord LSZH with Moulded boots Over-moulded boot at each end provide strain relief and maintains minimum bend radius of the cable - 1 Meter with Tender specifications and all the required accessories to complete the system. |
| 507 | Patch Panel for Data - Supply, Installation, Testing & Commissioning of 24 Port fully loaded Patch panel CAT6 (1U with rear wire manager) 45˚silver-plated IDCs (insulation displacement connection) for Secure, reliable gas-tight connections with Tender specifications and all the Required accessories to complete the system. |
| 508 | Patch Panel for Voice - Supply, Installation, Testing & Commissioning of 24 Port fully loaded Patch panel CAT6 (1U with rear wire manager) 45˚silver-plated IDCs (insulation displacement connection) for secure, reliable gas-tight connections with Tender specifications and all the required accessories to complete the system. |
| 509 | Fibre Patch Cable - Supply, Installation, Testing & commissioning of Fibre optic Patch Cords LSZH MM(SC to LC PC) - 50/125 - 3 Meter with Tender specifications and all the required accessories to complete the system. |
| 510 | Fibre Patch Cable - Supply, Installation, Testing & commissioning of Fibre optic Patch Cords LSZH MM(SC to LC PC) - 50/125 - 1 Meter with Tender specifications and all the required accessories to complete the system. |
| 511 | Supply, Installation, Testing & commissioning of Following Port LIU, 19\" rack mount, with adaptors, Swing-out splice tray in 1U Size. Should have front access for easy splice & patch management. Fully loaded with SC MM Pigtails & adapters for all the courses with Tender specifications and all the required accessories to complete the system.- 6 port Light Interface Unit |
| 512 | Supply, installation, testing and commissioing of following Network Rack with Front glass door, Rear Perforated door with handle Lock & key. Front / Rear mounting angles, top, bottom open, RAL 9005 / 7035 texture finish, including necesary exhaust / circulation fan, 19\" Power Socket Strip with all accessories required for complete installation as directed by the engineer in charge.- 9 U Network Rack |
| 513 | Supply, installation, testing and commissioing of following Network Rack with Front glass door, Rear Perforated door with handle Lock & key. Front / Rear mounting angles, top, bottom open, RAL 9005 / 7035 texture finish, including necesary exhaust / circulation fan, 19\" Power Socket Strip with all accessories required for complete installation as directed by the engineer in charge.- 12 U Network Rac |
| 514 | Supply, installation, testing and commissioing of following Network Rack with Front glass door, Rear Perforated door with handle Lock & key. Front / Rear mounting angles, top, bottom open, RAL 9005 / 7035 texture finish, including necesary exhaust / circulation fan, 19\" Power Socket Strip with all accessories required for complete installation as directed by the engineer in charge.- 15 U Network Rack |
| 515 | Supply and fixing of UnPerforated Cable tray with cover / Ceiling Raceway closed with snap fit lid, suitable supports and brackets and other accessories as required confirming to IEC-61537. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461. The Ceiling Raceway shall be supplied with cover with the standard length of 3 Mtr.-50 mm width x 60mm Height with Cover |
| 516 | Supply and fixing of UnPerforated Cable tray with cover / Ceiling Raceway closed with snap fit lid, suitable supports and brackets and other accessories as required confirming to IEC-61537. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461. The Ceiling Raceway shall be supplied with cover with the standard length of 3 Mtr.-100 mm width x 60mm Height with Cover |
| 517 | Supply and fixing of UnPerforated Cable tray with cover / Ceiling Raceway closed with snap fit lid, suitable supports and brackets and other accessories as required confirming to IEC-61537. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461. The Ceiling Raceway shall be supplied with cover with the standard length of 3 Mtr.-150 mm width x 60mm Height with Cover |
| 518 | Vertical Transportation System |
| 519 | Supply installation, testing and commissioning of gearless, machine room less type passenger lift of 1.5M/s Speed with all accessories, control equipment for a total travel of 18 Meters with 6 landing/stops (Ground to Fifth floor) and 6 opening, fully motorized doors and maximum capacity as per the detailed specification mentioned. The lift shall be with emergency alarm device, emergency light with UPS backup, overload protection, advance door opening, Relevelling operation facility, automated fan and light controls, LED Stop display on top of door side, Rescue operation to the next landing while door operation failure and lift stopped out of level zone etc. All landing shall be with entrance frame, landing doors of stain less steel hairline finish in 304 grande, hall indicators, hall call box with face plate and landing sill etc. with all accessories required for complete installation as required as per the standard and requirements. The scope of also include necessary approvals from concerned authority. Necessary shaft lighting and power sockets shall also be included in the scope of work including supply off necessary materials for shaft lighting and power sockets like bulk head light of approve make, switch socket, conduit wire etc. Speed - 1.5 M/s,Type of drive - Gearless, Travel distance - 18 Meters approx. No of stops / landings and openings - 6, Car ceiling - Stainless Steel hairline Finish in 304 Grade, Car flooring - Granite Flooring Car Illumination - LED Light Fittings of approved make No of entrance - One Location In Front Car entrance - Automatic Centre Opening Doors in Stainless Steel Finish in 304 Grade Door safety - Full Length Infra Red Light Curtain Landing Entrance Automatic Side/Center Opening Doors in SS Stainless Steel Finish in 304 Grade - Passenger Lift - 15 P - 1020 kgs (Available Shaft Size -2150(W) X 2950(D) mm |
| 520 | Supply installation, testing and commissioning of gearless, machine room less type passenger lift of 1.5 M/s Speed with all accessories, control equipment for a total travel of 18 Meters with 6 landing/stops (Ground to Fifth floor) and 6 opening, fully motorized doors and maximum capacity as per the detailed specification mentioned. The lift shall be with emergency alarm device, emergency light with UPS backup, overload protection, advance door opening, Relevelling operation facility, automated fan and light controls, LED Stop display on top of door side, Rescue operation to the next landing while door operation failure and lift stopped out of level zone etc. All landing shall be with entrance frame, landing doors of stain less steel hairline finish in 304 grande, hall indicators, hall call box with face plateand landing sill etc. with all accessories required for complete installation as required as per the standard and requirements. The scope of also include necessary approvals from concerned authority. Necessary shaft lighting and power sockets shall also be included in the scope of work including supply off necessary materials for shaft lighting and power sockets like bulk head light of approve make, switch socket, conduit wire etc. Speed - 1.5 M/s,Type of drive - Gearless, Travel distance - 18 Meters approx. No of stops / landings and openings - 6, Car ceiling - Stainless Steel hairline Finish in 304 Grade, Car flooring - Granite Flooring Car Illumination - LED Light Fittings of approved make No of entrance - One Location In Front Car entrance - Automatic Centre Opening Doors in Stainless Steel Finish in 304 GradeDoor safety - Full Length Infra Red Light Curtain Landing Entrance Automatic Side/Center Opening Doors in SS Stainless Steel Finish in 304 Grade - Passenger Lift - 10 P - 680 kgs (Available Shaft Size - 2150(W) X 1900(D) mm) |
| 521 | Grid Connected Solar System |
| 522 | 30 kWp Grid Tied Solar Power Plant with Three Phase Solar Inverter: Supply, installation, testing and commissioing of 30 kWp grid tied solar power plant with all necessary materials required for complete installation as per the approved drawing and as per the detailed technical Specification. The cost inclusive of Solar Panels, Inverter, Panel mount with all necessary frames and fabrication works, panels& Distribution boards, Cables, wires and its connections, necessary earthing system with all accessories required for complete instalation including necessary approvals with KSEBL and KSEI and as directed bythe engineer in charge. Please Enable Macros to View BoQ information |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy